Siemens AS 488 User's Manual

image

Contents

1. The version V2 00 of PROFIBUS PLC PLC can further be used unchanged order no 6DS5 124 1AA SIWA block The version V1 02 of the driver for SIWAREX M can further be used unchanged order no 6DS5 470 1AD PROFIBUS PA Link The special version M02 00 01 delivered with this software package has been included in the standard system software M02 01 i e the modules from the directory M02_00 01 on the diskette Linking PROFIBUS PA to AS x88 TM must no longer be copied on the memory card with M02 02 01 or MO1 08 07 The version V1 00 of the file PA_TREIB NL delivered with this software package can further be used unchanged Order no 6DS5 130 8AA or 8AB Copyright SIEMENS AG 1996 2001 All Rights Reserved 79220 A0977 A 10 7637 Page 12 of 18 Product Information November 2001 AS 488 TM MO02 02 3 Removed Errors Function concerned Appearance Modification zm ASBEDIEN command LANW The transmission doesn t work Afterwards also the other commands don t work COPY_PC COPY_TM DIR_TM Operating task corrected within the AS system software m S5KS S5KE When utilizing the maximum permissible message frame length of 128 bytes with TELEPERM I O modules the telegram is rejected shorter and longer telegrams are working M S5KS and SSKE blocks corrected zm Note Both errors described above have been removed already with the correction version M02 11b e F ASBEDIEN doesn t link with some user structu
2. 3 2 Update by Programming Device PG740 Before starting the UPDATE activities pulling the memory card please ensure that a current backup of the customer s system and any files that are to be modified exists This will allow the previous software version to be restored in the even of unforeseen circumstances Stop your AS running e g with STO and then switch the AS off before pulling the memory card Copy the files listed under 2 3 1 from the upgrade update directories into a new directory having the name of your PG740 For the update insert the memory card into the MEM CARD slot of the PG740 Now copy all files from the directory name onto the memory card either using the file manager or explorer or using a DOS box COPY name E y Now perform the following two steps 1 Plug the upgraded memory card of the AS back into the allocated AS 488 TM and initiate a reboot of the AS 488 TM power on 2 Install the new terminal program ASBEDIEN V1 08 to your PC from the second diskette IBS tools included with your delivery To check the update procedure start the new ASBEDIEN and select the AS status screen BT STAT In addition to the start up message the system version M01 08 is displayed Copyright SIEMENS AG 1996 2001 All Rights Reserved 79220 A0977 A 10 7637 Page 10 of 18 Product Information November 2001 AS 488 TM MO02 02 2 4 Installation of the Reloadable DP Driver Blocks DPAE DPAA DPBE
3. DPBA In addition to the execution system and the standard blocks of the AS 488 TM your memory card contains a so called reloadable file with the optimized driver blocks for the PROFIBUS DP I O bus These blocks are not present in the system data area of the AS and are thus not activated automatically You can load these blocks into your user memory and activate them To do this install your Commissioning terminal and transfer the blocks from your memory card to the user memory of your AS using the operation LA DP_TREIB NL The loaded blocks must then be parameterized to the type numbers provided in their application and activated You activate the parameter settings in the AS input mode using the input instruction BT DP Set the desired type numbers of the DP blocks in the parameterization display using the parameters 1 3 5 and 7 If this blocks already are existing in the AS the existing type numbers were accepted Your parameter settings are accepted using the parameterization input P 9 1 and the blocks are stored in the user memory of your AS The activation procedure can be previously aborted using P 11 1 The reloaded file is then no longer present in your AS However you can carry out the installation procedure from the beginning If you already have installed DP driver blocks and you want to update your system software you have to update the algorithm of the DP driver blocks After successful activation the user st
4. grafic module min 1024 x 768 for the big display When using the CS 275 system bus additionally the driver NAT32 has to be installed for the interface modules N AT N PCI This happens by starting the installation program SETUP EXE in the NAT NPCI directory During installation the hardware I O address for the N AT interface module has to be given using the N PCI this input is irrelevant because it is determined by the driver If this I O address should be changed later the driver has to be deinstalled and installed again via NAT NPCI Setup exe When using the PROFIBUS TM system bus a corresponding driver of SIMATIC NET is used for the interface modules CP5412 CP5613 which has to be installed separately delivered with the CP The Bus Operating Console works with Windows NT 4 0 and Windows 2000 Copyright SIEMENS AG 1996 2001 All Rights Reserved S79220 A0977 A 10 7637 Page 15 of 18 Product Information November 2001 AS 488 TM MO02 02 5 Extended Documentation 5 1 Restart of AS 488 TM with Interface Module TPM 478 With each restart of the AS 488 TM the interface module TPM 478 will be parameterized new This happens with Power on Boot by MRES key switch RSOF by operation or key switch Loading LA name or LA name Loading via bus LAB or LABR LOES During this parameterization the SYST WART configuration is passed to the TPM 478 module and a restart of the TPM 478 is activated Consequently the process im
5. set files FNT needed for the correct screen display have to be copied into the Windows system directory FONTS during installation of ASBEDIEN NT If they are already existing there e g by PROGRAF AS NT the old character sets have to be deleted first The new ones are compatible to those of PROGRAF AS NT and are included also in the new version 4 01 of PROGRAF AS NT With these character sets the AS characters and therefore the ASBEDI_E window can be displayed with two sizes The selection small or big depends on the resolution of the used grafic module min 1152 x 864 for the big display Copyright SIEMENS AG 1996 2001 All Rights Reserved 79220 A0977 A 10 7637 Page 14 of 18 Product Information November 2001 AS 488 TM MO02 02 4 3 Online Configuring as Stand alone Operating Terminal As replacement for an AS 230 235 local operating console with screen configuration and process operating keyboard the Online Configuring Console of PROGRAF AS NT has been extended for AS 488 TM with the following functions colored picture transmission PBT process operating console function keys analogous to ASBEDIEN The programm for the bus operating console is delivered as self extracting file on a separate diskette in case no PROGRAF AS NT is available But the new functions are also included in the version 4 01 of PROGRAF AS NT The user description is included in the file BUS_BEDI_E DOC The current AS 488 TM system software M0
6. starting up is found in this file and the following files DIODEF_E doc Description of the pin allocations for the DIO interface module for cabinet status signals such as door contact fan etc BUSINI_E doc Configuration for operating your AS 488 TM on the CS 275 or PROFIBUS TM system bus PERPRO_E doc Configuring the Teleperm M I O peripherals DP_PRO_E doc Configuring the PROFIBUS DP peripheral The INI files that need modifying for the parameter settings can be found on the AS 488 TM memory card or the upgrade update diskette DP_BST_E doc Description of the standard DP driver blocks IP262_E doc Description of the standard driver blocks for IP262 Please print out these document files and add them to your AS 488 TM documents Failure to observe the information provided can result in a serious malfunction of the installation If you do not have the corresponding Windows installation on your PC your local Siemens representative will be pleased to help you Copyright SIEMENS AG 1996 2001 All Rights Reserved S79220 A0977 A 10 7637 Page 3 of 18 Product Information November 2001 AS 488 TM MO02 02 1 2 AS System File for PROGRAF AS Your commisioning diskette contains a directory PROGRAF after extracting This contains the system file AS SYS required for PROGRAF AS Copy the file AS SYS into your PROGRAF PC into the directory drv PROGRAF USER The system file of the AS 488 TM automation system is then known to PROGRAF AS
7. 2 02 is needed to use the new functions an updated version M01 08 is not enough But this AS system software and the bus operating console are complete downward compatible i e the new online configuring console works also with all previous issues of the system software black and white without PBT function keys In the same way the system software M02 02 works further with all previous configuring programs of PROGRAF AS Installation A directory BUS_BEDI is extracted by starting the file BUSBEDI EXE For the German version you have to use the files BUS BEDI EXE and BUS _BEDI INI from this for the English version the files BUS_BEDI_E EXE and BUS_BEDI INI The settings within the file BUS BEDI INI have to be set by the user see description BUS_BEDI DOC If you use PROFIBUS TM the file S7ONLINX DLL is needed additionally Both character set files F NT needed for the correct screen display have to be copied into the Windows system directory FONTS during installation of the bus operating console If they are already present there e g by PROGRAF AS NT the old character sets have to be deleted first The new ones are compatible to those of PROGRAF AS NT and are also included in the new version 4 01 of PROGRAF AS NT They correspond to those used with ASBEDIEN NT With these character sets the AS characters and for that the ASBEDIEN window can be displayed with two sizes The selection small or big depends on the resolution of the used
8. Carry out your PROGRAF AS configuring in the usual manner Note From PROGRAF AS V3 00 onwards the AS commands FORM LA AR DI and DEL are also allowed for online structuring After LA name PROGRAF AS terminates the coupling to AS 488 TM message BUS STRUCTURING ABORTED The coupling must be re established after the loading and reset procedure is complete new ANMS Caution Under no circumstances should PROGRAF AS be stopped while the AS is being reset as this causes the bus structuring in the AS to remain active If it should happen nonetheless the user of PROGRAF AS should logon on the same AS 1 3 Master Type File for COM ET200 COM PROFIBUS In the DOKU folder on the IBS tool diskette there are two files for the ET200 configuration tool COM ET200 or COM PROFIBUS The master type file SIB050AX 2MH must be copied to the MASTERS directory of the installed COM PROFIBUS Its contents specify the AS 488 TM as the host system and the module card IF964 as the DP master The bitmap file AS488TM BMP must be copied into the BITMAPS directory Once COM PROFIBUS is started the Read in type files menu item or the Read in GSD files menu item from within the file menu need be activated only once see also DP_PRO_D doc Note In the case of COM PROFIBUS these files are already supplied from V3 1 onwards Copyright SIEMENS AG 1996 2001 All Rights Reserved 79220 A0977 A 10 7637 Page 4 of 18 Prod
9. SIEMENS Program Library Karlsruhe S79220 A0977 A 10 7637 Product Information AS 488 TM Var M02 02 Issue November 2001 Descriptors TELEPERM M AS 488 TM Software variant M UPGRADE UPDATE Summary The present Product Information relates to the System Software Package AS 488 TM 02 02 6DS2 410 0XX00 0XA0 6DS2 410 0XX00 0XBO AS 488 TM 02 02 6DS2 410 0XX00 0XC2 upgrade update 01 08 Description Erg nzende Systemdoku AS 488 TM German C79000 G8000 C700 Supplem System Docu AS 488 TM English C79000 G8076 C700 This manuals have to be ordered seperate if required SIEMENS AG 1996 2001 Anderungen vorbehalten Subject to alteration Sous r serve de modications Con riserva di modifiche Product Information November 2001 AS 488 TM M02 02 1 Scope The product information for the system software M02 01 M01 07 remains valid The following information represents a supplement The delivery consists of 6DS2 410 0XX00 0XA0 6DS2 410 0XX00 0XC2 6DS2 410 0XX00 0XBO Upgrade Update AS 488 TM Memory Card Diskette 3 5 with AS 488 TM software Diskette 3 5 with tools for Diskette 3 5 with tools for installation installation Software contract and Software contract registration card Product Information Product Information Note on software protection The memory card must be considered as part of the CPU If the memory card is removed during current operation and if the AS 488 TM e
10. age of the TPM 478 is rebuild starting from a zero state Therefore 0 values are output to the I O modules as long as the assigned process image is set by RESTART and driver blocks Because this function mode is independent from a HW driven restart the short time output of 0 values is done also if the so called ARS jumper on the I O modules is configured to hold Beyond these zero values are output by power failure of triggering the fuses of binary and analog output modules with ARS switch or there racks expansion units Because the zero state cannot be assumed as identically with the so called safe state the user has to plan a subordinate clearance plane for all security relevant signals During configuration of the process it has to be guaranteed that for protection of people and installations a secondary security system exits independent from the control system New restart reaction Up from system software version M02 01 restart and configuring of the TPM 478 has been extended to the effect that with RSOF the output of the TPM 478 process image to the I O modules is enabled not until the first pass of AS cycle 3 With this a bumpless transition without 0 output on the process signal outputs has been made possible for warm restart Note This modified function has to be enabled explicit by GB ORPA 262 1 In the first pass of the AS cycle 3 all wanted starting states within the process image have to be configured With use
11. am runs in full screen mode and without a screen saver Now in command mode copy the files previously backed up to the PC to the memory card in the AS in the following sequence lt esco gt COPY TM IBS BEDI 386 resp lt esc gt COPY_ TM C ASBEDIEN IBS BEDI 386 lt esc gt COPY TM STARTER 386 resp lt sscs COPY TM C TEMP STARTER 386 lt esco gt COPY TM BEDIEN 386 lt esco gt COPY TM BUSTASK 386 lt esco gt COPY TM EATASK 386 lt esco gt COPY TM LA AR 386 lt esc gt COPY TM EMULATOR EXE lt esc gt COPY TM FUNC EXE lt Esc gt COPY TM C EAM EX lt Esc gt COPY TM AR DG EX lt Esc gt COPY TM RMOS IN lt esc gt COPY TM M7 235AR SYS lt esc gt COPY TM VERSION TXT lt Esc gt COPY TM DP TREIB NL lt esc gt COPY TM IP262 NL lt esc gt COPY TM FENS NL lt esc gt COPY TM NAS DIAG NL If necessary the following files in directory A INI should be modified in accordance with the new configuration guidelines AS KOM IN settings for non redundant operation of the CS 275 bus DP1 IN parameters for pull amp plug diagnosis and ODIS DP2 IN parameters for 2nd DP line L2AMPRO IN parameters for system bus PROFIBUS TM After a successful transfer exit ASBEDIEN with Alt X Now perform the following two steps 3 Initiate a reboot o
12. ember 2001 AS 488 TM MO02 02 2 2 Procedure for Upgrade to M02 02 with Programming Device PG740 Stop your AS running e g with STO and then switch the AS off before pulling the memory card For the upgrade insert the memory card into the MEM CARD slot of the PG740 Now start the batch UPGRADE BAT if applicable information on the memory card drive default setting is E resp the corresponding link Syntax UPGRADE or UPGRADE E This batch file creates a directory C UPGRADE 202 for this at least 2 to 8 MB must be free on drive C depending on the size of the user software copies all files from memory card into the upgrade directory deletes the RMOS system file as this can never be copied to the MC deletes all BAK files copies the packed upgrade files from disk into the directory the system files to be upgraded are then overwritten reformats the memory card and sets up the RMOS system copies all files from the upgrade directory to the memory card Now perform the following two steps 1 Put the upgraded memory card in the allocated AS 488 TM and initiate a reboot of the AS power on 2 Install the new terminal program ASBEDIEN V1 08 or V2 00 to your PC from the diskette IBS tools included with your delivery To check the update procedure start the new ASBEDIEN and select the AS status screen BT STAT In addition to the start up message the system version M02 02 is displayed Note
13. f the AS 488 TM reset or off on 4 Install the new terminal program ASBEDIEN V1 08 or V2 00 to your PC from the diskette IBS tools included with your delivery Copyright SIEMENS AG 1996 2001 All Rights Reserved S79220 A0977 A 10 7637 Page 9 of 18 Product Information November 2001 AS 488 TM MO02 02 To check the update procedure start the new ASBEDIEN and select the AS status screen BT STAT In addition to the start up message the system version M01 08 is displayed Note If there is already a version M02 01 on the memory card you can use the files from directory C UPGRADE AS_SW 202 M02 02 instead of the files from C UPGRADE Update_M 108 for the online update additionally to the files from C UPGRADE AS_SW 202 From this results a version M02 02 Attention The data transfer was only successful if the command COPY_TM ends without error messages and without any manual intervention e g termination with ESC In the case of errors the copy procedure must be repeated If problems occur during the data transfer frequent terminations we recommend the following procedure e If the first file IBS BEDI 386 was transferred without errors the AS can be rebooted with the new emergency utility disk press MRES during switch on Together with the new ASBEDIEN V1 08 or V2 00 an error free transfer can be expected e Before the next RESET the files IBS_BEDI 386 and STARTER 386 must be successfully transferred 2
14. ion using the ASCII editors which can be executed under DOS and then write them back onto your memory card using the ASBEDIEN command COPY_TM Note Before starting the UPGRADE UPDATE activities please ensure that a current backup of the customer s system and any files that are to be modified exists This will allow the previous software version to be restored in the even of unforeseen circumstances The files on the memory card are not write protected so care should be taken when accessing the memory card To back up the files from the memory card to your archive use the ASBEDIEN command COPY lt PG 2 1 1 Upgrade Update Data The data for the upgrade update procedure is existing on the upgrade diskette as self extracting exe file For extracting please start the file UPGRADE EXE If the pre adjusted path is kept the following directory structure is created on your PC programming device C UPGRADE Upgrade batch C UPGRADE AS_SW 202 AS system software M02 02 C UPGRADE CP5412 Files for operating the system bus with CP5412 C UPGRADE INI Initialization files for restoring C UPGRADE RMOS32 Programs for formatting procedure C UPGRADE Update_M 108 Data for update to M01 08 If a different path as C has been selected while extracting the environment variable UP_DRIVE has to be changed in UPGRADE BAT Copyright SIEMENS AG 1996 2001 All Rights Reserved 79220 A0977 A 10 7637 Page 6 of 18 Product Information Nov
15. nd the standard blocks of the AS 488 TM your memory card contains a so called reloadable file with the optimized driver blocks for the controller module IP262 These blocks are not present in the system data area of the AS and are thus not activated automatically You can load these blocks into your user memory and activate them To do this install your Commissioning terminal and transfer the blocks from your memory card to the user memory of your AS using the ASBEDIEN command LA IP262 NL The loaded blocks must then be parameterized to the type numbers provided in their application and activated You activate the parameter settings in the AS input mode using the input instruction BT IP Set the desired type numbers of the driver blocks in the parameterization display using the parameters 1 und 3 If this blocks already are existing in the AS the existing type numbers were accepted Your parameter settings are accepted using the parameterization input P 7 1 and the blocks are stored in the user memory of your AS The activation procedure can be previously aborted using P 9 1 The reloaded file is then no longer present in your AS However you can carry out the installation procedure from the beginning After successful activation the user structure and the driver blocks must be re archived to the memory card otherwise they will be lost during the next boot procedure 2 6 Extension Software Packages for AS 488 TM PLC PLC Link
16. nters STOP as a result of the software protection all modifications to the configuration are lost which have been made in the meantime and which have not been saved as well as all modified inputs which have been made since the last save operation I O modules may be reset to the basic status Note to the Diskette IBS Tools Hinweise Commissioning Tools Notes Because of space the data on the IBS tool diskette is existing now as a self extracting exe file For extracting please start the file IBS _DISK EXE With this the following directory structure is created on your PC programming device MBS_DISK M2 ASBEDIEN ASBEDIEN V1 08 MBS_DISK M2 ASBEDIEN NT ASBEDIEN V2 00 for Windows NT IBS_DISK M2 DOKU Supplementary Documentation see chapter 1 1 MBS_DISK M2 PROGRAF AS system file for PROGRAF AS see chapter 1 2 Copyright SIEMENS AG 1996 2001 All Rights Reserved 79220 A0977 A 10 7637 Page 2 of 18 Product Information November 2001 AS 488 TM MO02 02 1 1 Supplementary Documentation In addition to the tools required for startup of your AS 488 TM the commissioning diskette contains a document file for the service terminal within the directory ASBEDIEN or ASBEDIEN NT ASBEDI_E doc User description for the Commissioning Terminal IBS terminal For further information by seperate ordering to C79000 G8076 C700 please ask your Siemens sales partner for a document diskette This information which may be useful when
17. of XB blocks AP 1 is absolute necessary Caution Requirement for this new function is a TPM 478 module issue 9 resp a TPM 478 1 from issue 1 For the TPM 478 exists an upgrade package order no 6 DS9 630 8AA Copyright SIEMENS AG 1996 2001 All Rights Reserved 79220 A0977 A 10 7637 Page 16 of 18 Product Information November 2001 AS 488 TM MO02 02 6 Limited Operating Performance No safety relevant software faults are currently known the known faults are assigned to fault class 3 and lower Caution When working on initialization files INI tabs O9H should not be used Spaces 20H should be used instead Failure to comply could lead to interpretation errors AS 488 TM with TELEPERM M_1 Os The limitations with respect to use of TM I Os module types all TM modules listed in the AS388 TM and AS488 TM supplementary system documentation C79000 G8076 C700 or at catalogue PLT 112 and official notes in TELEPERM M aktuell can be used Errors failures faults of the I O buses are not displayed by LEDs on the TPM 478 these can be recognized e g by failure signals of the drivers The module 6DS1607 operates with compatible functions but the pulses which have been accumulated in the previous cycle are always output when reading The dead time is reduced if a faster TPM 478 cycle is configured Operation of the coupling modules 6DS1318 8AB and 6DS1333 8AB as well as CP581 TM as far as compatible to S5Kx dri
18. or floating point constants in TML The CD coupling is not implemented in the AS 488 TM Any attempt to register a CD coupling from OS or AS 235 will be rejected Remedy When importing structures CD couplings must be replaced by DI couplings before loading Loading a filed structure from AS to AS using the command LAB name is only possible from an AS 235 with a diskette drive Saving from AS to AS on diskette using the command ARB name is only possible on an AS 235 with diskette drive Use of an AS 488 TM as the central configuring station is not envisaged i e all commands which are not directed to the own AS like for example the LABR and ARBR commands are not allowed from the AS 488 TM and may lead to malfunctions in both AS When using the function Read RAM by PROGRAF AS from an AS 488 TM the number of transmit telegrams per cycle in the AS is limited by the parameter settings of FSA ORPA in the AS 488 TM A FSA ORPA F P 26 10 Structuring of I O modules with STRUK EA via the system bus CS 275 or PROFIBUS TM has not been released for AS 488 TM S5KS Blocks When projecting S5KS blocks special care must be taken to ensure that these are always placed in the same cycle for the same module and the same channel The S5KS blocks use a joint send buffer for each module and channel If this send buffer is accessed at the same time by two cycle levels for example by cycle 2 and 3 with the S5KS blocks the send data to be
19. res A There are user structures including a SIGRID V4 package with MELD blocks from SIGRID V3 In this case a dual restart triggered by the block RESTART MELD leads to a blocking of the operating task within the AS This blockade only appears if the AS is rebooted and loaded with the structure automatically not after loading with LA name M The operating task within the AS system software now tolerates this inadmissible dual restart e F Upgrade batch B On newer programming devices with Windows NT or 2000 the formatting program for the memory card doesn t work i e the upgrade batch finishes without error message but the RMOS operating system is not replaced With this a restored memory card is not bootable The batch uses a newer version of the formatting program now 3 1 General Note Within the state view BT STAT the state of bus A and bus B is shown for the system bus CS 275 or PROFIBUS TM With redundant CS 275 bus this state corresponds to the state of redundancy the state values AKTIV active PASSIV passive or STOER fault may appear at both busses With not redundant CS 275 bus or with PROFIBUS TM the bus B can never take the state AKTIV but only PASSIV or STOER both state values show that bus B is not existing If the AS 488 TM at system bus PROFIBUS TM is coupled to the CS 275 bus via a Bridge CS L2 the bus state values within the state view represent the bus state of the CS 275 bus as soon as a redundanc
20. ructure and the driver blocks must be re archived to the memory card otherwise they will be lost during the next boot procedure Note The data structures of the DP driver for CP581TM in AS230 235 and AS 488 TM are identically but the program algorithms have to be exchanged With transfering of old user structures to AS 488 TM following steps have to be done Install matching driver programs BT DP see above Input again the parameters BGNR and BADR in all block instancies even if there value doesn t change the check has to be run through Note DPAE driver and analogue input modules with NAMUR range of values for wire breakage The DPAE driver does not know the NAMUR range of values for wire breakage e g AE module 6ES7 331 7RDO However with correct configuration the AE modules can be made to return the S7 standard value 7FFF hex if a wire does actually break this is then interpreted by the DPAE driver as a wire breakage in order to do this the release of the wire breakage diagnosis should be parameterised using COM PROFIBUS further information can be found in the S7 manual Ex peripheral modules which can be ordered quoting reference no C7900 G7076 C150 Copyright SIEMENS AG 1996 2001 All Rights Reserved S79220 A0977 A 10 7637 Page 11 of 18 Product Information November 2001 AS 488 TM M02 02 2 5 Installation of the Reloadable IP262 Driver Blocks RIP KRIP In addition to the execution system a
21. s Subdirectories on the Memory Card will not be copied These have to be saved to PC Programming device bevor starting the upgrade procedure The upgrade directory is not deleted This means that if an error should occur during the upgrade process the process can be repeated Attention If more than one AS 488 TM memory cards are upgraded the directory must either be deleted or renamed between the individual upgrade processes The directory can also be used as a backup copy of the entire AS software system and user software This means that repairs can be carried out on memory cards with defective software create directory UPGRADE 202 copy backed up file to it and start the batch file Copyright SIEMENS AG 1996 2001 All Rights Reserved S79220 A0977 A 10 7637 Page 7 of 18 Product Information November 2001 AS 488 TM MO02 02 2 2 1 Restoring a Memory Card This restore is necessary if the memory card is no longer bootable on an AS 488 TM if it has been deleted with the SIMATIC Manager for example The procedure corresponds to an upgrade see chapter 2 2 Special features e Attempting to copy the old files from the memory card to the programming device with a faulty empty memory card appears the error message Not ready when reading from drive E Ignore retry error This message has to be acknowledged with i After that the MC will be formatted e Afterwards some INI files have to be copied from the direc
22. tory C UPGRADE INI to the memory card and modified specifically for the user AS KOM IN settings for the system bus DP1 IN parameters for the 1st DP thread DP2 IN parameters for the 2nd DP thread L2AMPRO IN parameters for the system bus PROFIBUS TM STARTER IN starting parameters poss enter add ons e Using a CP5412 for the system bus PROFIBUS TM you have to copy the files DOS_CONF DAT and FW5412 from the directory C UPGRADE CP5412 to the memory card instead of the file LAAMPRO INI If the display of the AS 488 TM serial number 48xxxx in BT STAT is faulty please contact the TELEPERM M hotline Tel 49 721 595 4400 Copyright SIEMENS AG 1996 2001 All Rights Reserved 79220 A0977 A 10 7637 Page 8 of 18 Product Information November 2001 AS 488 TM MO02 02 2 3 Procedure for Update M01 07 resp M01 06 05 04 to M01 08 2 3 1 Update by Commissioning Terminal You will find the files needed for an update on the UPGRADE UPDATE diskette too Please copy all files from the directory C UPGRADE AS_SW 202 without sub directory M02 02 and from the directory C UPGRADE UPDATE_M 108 to the directory C ASBEDIEN on your Commissioning Terminal PC or into the current working directory e g C TEMP is specified in ASBEDIEN PIF On the Commissioning Terminal PC connected to the AS 488 TM start the program ASBEDIEN exe via ASBEDIEN PIF under Windows 3 11 so that the progr
23. transported can occasionally be corrupted or destroyed when it enters the send buffer the receiver then receives corrupt data Time after network is switched on On rare occasions it may be the case that despite the battery memory the time on the AS 488 TM is reset to 01 01 94 00 00 00 when turned on Correction offline Start a terminal program e g windows terminal or HyperTerminal on the IBS terminal PC which is connected to the serial port COM1 Settings 19200 Baud no parity 8 data bits 1 stop bit Then call up the BIOS setup press Q and switch on the CPU Set the correct date in the setup menu and save the settings After this has been set once the battery memory will function for the date and the time Copyright SIEMENS AG 1996 2001 All Rights Reserved 79220 A0977 A 10 7637 Page 18 of 18
24. tware switch for up to four AS interfaces Copyright SIEMENS AG 1996 2001 All Rights Reserved S79220 A0977 A 10 7637 Page 5 of 18 Product Information November 2001 AS 488 TM MO02 02 2 1 Startup by Commissioning Terminal The extracted IBS tool diskette contains your local tool in the directory ASBEDIEN Install this on your PC to be used for commissioning of the AS 488 TM according to the installation instructions in the document file ASBEDI_E DOC in the directory ASBEDIEN and connect your PC to the serial commissioning interface of your AS 488 TM via a serial interface For operation under Windows 3 1 a PIF file is delivered with the software This contains the following settings run in full screen mode exclusive foreground execution foreground priority very high For operation under Windows 95 the following setting should be specified idle time activity very low no screen saver Alternatively the new NT version can be used see chapter 4 2 Using your Commissioning terminal installed in this manner and the commands of the ASBEDIEN input program you can operate and monitor your AS 488 TM for install and diagnostic like an AS 235 and also access all data on the memory card inserted in the AS 488 TM Read the parameter files which have to be processed to enable parameterization from the memory card into a file on your PC using the command COPY_PC You can modify this file on your PC according to your system configurat
25. uct Information November 2001 AS 488 TM MO02 02 2 Commissioning The Memory Card contains the entire system software for AS 488 TM It responds with the version ID M02 02 To perform an upgrade or update from diskette an AS 488 TM memory card must be available The upgrade procedure is performed offline with a PC or a programming device having a compatible MC interface e g PG740 The update procedure is performed either from the IBS terminal online or from a programming device having a compatible MC interface e g PG740 A description of the upgrade procedure is provided under heading 2 2 in this document of the update procedure under heading 2 3 Caution The file RM3_PC1 SYS on the memory card must never be deleted or overwritten as this would mean that the memory card would no longer be bootable If this happens nevertheless the memory card can be restored on a programming device with the help of the upgrade diskette see chapter 2 2 1 Notes The V 24 serial interfaces of the AS 488 TM and the PCs are non isolated With a distance of more than 10m between the earthable point of the AS and the earthable point of the PC s protective conductor an electrical isolation of the interface has to be planned Further electronic switches for multiplication of the PC s serial interfaces are not suitable for the commissioning terminal because of the interruption of telegrams at any point We recommend the use of the integrated sof
26. ver When using the firmware TPM 478 IO part version 2 Fixed memory package S79300 G196 A900 1 position S79300 G196 A903 2 2 position S79300 G196 A904 2 only telegrams with a maximum of 32 data words may be configured Longer telegrams should be split into two shorter ones From module version 6 onwards firmware version 3 is used which allows a maximum of 64 data words to be configured AS 488 TM with PROFIBUS DP I Os The process image length per slave station via PROFIBUS DP is limited by the IF964 DP to 122 bytes It is thus possible to operate up to 7 analog modules with 8 channels each in one slave station New modules can only be released for operation on the AS 488 TM by publishing them in the PLT 112 Catalog or as an addendum to TELEPERM M aktuell When configuring ET200 I O modules using COM ET200M the value for the internal monitoring time is calculated too low by the tool The result may be that I O modules are not recognized removed from COM PROFIBUS V3 0 Remedy Increase the value calculated by COM ET200M by a factor of 2 Copyright SIEMENS AG 1996 2001 All Rights Reserved S79220 A0977 A 10 7637 Page 17 of 18 Product Information November 2001 AS 488 TM M02 02 Further information The arithmetic accuracy of the AS 488 TM with floating point numbers is higher than that of the AS 235 There may therefore be small deviations in the last digits of the mantissa in the case of calculated analog values
27. y message has been received by the AS 488 TM With not redundant CS 275 the interpretation above PASSIV or STOER applies for bus B as well Copyright SIEMENS AG 1996 2001 All Rights Reserved S79220 A0977 A 10 7637 Page 13 of 18 Product Information November 2001 AS 488 TM MO02 02 4 Extended Functions 4 1 General Extensions F Function concerned A Appearance E Extension e F Central configuration via bus A If the disconnection is not finished correctly the AS continues transmitting picture data S 38x is appearing as error message If another AS is selected from the configuration AS via ANMS pictures were shown from the last linked AS and the new linked AS alternately E Now unfamiliar AS picture data were rejected and reported with the new system error message S 397 including the bus station no of the faulty transmitting AS error text Picture data from no longer linked AS 4 2 ASBEDIEN under Windows NT There is a new version 2 0 of the operating program in the directory ASBEDIEN NT on the extracted IBS tool diskette now which works under Windows NT 2000 You can choose a German or an English program version see below and the user documentation ASBEDIEN doc or ASBEDI_E doc Installation For the German version you have to use the files ASBEDIEN EXE ASBEDIEN ERR and ASBEDIEN INI from the directory ASBEDIEN NT for the English version the files ASBEDI_E EXE ASBEDI_E ERR and ASBEDIEN INI The two character