1. and symbols C F REL are flashing The recommended best practice is to always zero the Aquant with respect to the environment in which it is about to be used even if the display shows 0 Read the Operation section above for details 3 Hold Feature The relative value shown on the display may be held for 3 seconds by pressing 4 while the Aquant is being held against a surface This feature is useful when using the instrument in areas where the display cannot be clearly seen 4 Auto Switch Off Override Feature Press and hold 1 for 3 seconds to switch the instrument OFF 5 User Set Up Options The Aquant is initially set up to switch OFF automatically after 1 minute and to emit an audible beep for readings beyond the yellow zone The user may change these default settings by entering the Set up mode Setup the User Options as follows 1 With the instrument switched OFF press and hold the lower button and switch ON using the upper button D The display will show the firmware version number e g 4 06 until both buttons are released Page 2 GE Protimeter Aquant 2 Scroll across the display and record the following information a part number bLd5760 b firmware date in the form yy mm dd e g 04 05 20 c calibration code e g E1 1 Note Once the scrolling is complete display shows 0 0 meaning that option 0 is set to 0 The C and buttons may now be used to change the i
2. GE Protimeter Aquant Sensing User Instructions Introduction The GE Protimeter Aquant BLD5760 moisture detector is used to assess and monitor the relative moisture level of non conductive and porous materials such as plaster masonry concrete and fiberglass GRP It is an ideal instrument for making rapid surveys of solid walls and floors and to pinpoint areas of concern in tiled shower cubicles GRP boat hulls motor homes and caravans etc The Aquant BLD5760 has a digital display that is synchronized with a color coded LED scale The digital display shows the relative moisture level of the material under investigation on a scale of 0 1000 and the LED scale indicates moisture condition of the material The color coded zones signify the moisture condition of the material under investigation The green yellow and red color coded zones indicate the following e Material in the green zone is in a safe air dry condition In the yellow zone moisture levels are higher than normal but not critical further investigation is recommended The red zone represents excessive moisture levels If sustained red zone moisture levels will lead to decay in organic materials 1 Operation The Aquant BLD5760 moisture detector has a radio frequency transceiver located in the bulge on it s underside to give relative readings within the material against which it is held up to a nominal depth of 3 4 in 19 mm The depth of measurement is su
3. bject to the characteristics of the material under test To use the Aquant do the following 1 Hold the Aquant away from surfaces as shown and switch ON by pressing O momentarily The instrument may now be used to take measurements or zeroed as appropriate 2 Zero the instrument with respect to the environment in which it is about to be used by pressing and holding for 3 seconds until the word nuL appears in the display 3 Release nuL will flash for a few seconds and then disappear from the screen The Aquant is now zeroed INS5760 Rev A1 April 2007 4 Place the instrument against the surface of the wall floor or element at the chosen point of measurement as shown Ensure that your forefinger and thumb do not extend beyond the top of the black plastic grip band and wrap all fingers around the side of the instrument Note The Aquant should be held at a nominal 25 to the surface so that both top edge of the instrument and the sensor bulge are in contact with the surface 5 Read the relative moisture level value from the display and note that moisture condition of the material from the color coded LED scale 2 Zero Feature The zeroing feature enables the user to compensate for the effects of changes in temperature on the calibration It is necessary to zero the Aquant if the following appear on the display when the instrument is held in air away from surfaces numbers or three lines
4. nstrument options and settings respectively as detailed in Table 1 below TABLE 1 User Set Up Options 1 When gt And Setting Option No Is Number Is Aquant Set Up Is Instruments settings are not changed from previous settings Instrument default settings loaded switches OFF automatically after 1 minute beeper is activated factory set zeroing Beeper is switched OFF Beeper beeps when switching from one mode to the other Beeper beeps with increasing frequency from nominal value of 170 Auto switch OFF is not active Instrument can only be switched OFF by pressing 1 and holding it for over 3 sec Auto switch OFF is active Instrument switches OFF after 1 minutes Auto switch OFF is active Instrument switches OFF after 2 minutes Auto switch OFF is active Instrument switches OFF after 3 minutes Note The instrument options can only be changed in numerical order 0 1 and 2 respectively Save setting changes and exit the Set up mode by pressing D again as in Step 4 of the following example Example To switch the audible beeper OFF and set the auto switch OFF time to 3 minutes complete the following steps 1 Press and hold followed by 1 to enter Set up mode 2 When display shows 0 0 press 4 once to select beeper options 1 then press until the display shows 1 0 GE Protimeter Aquant Page 3 3 Press 1 once again to select auto switch off options 2 then press u
5. ntil the display shows 2 5 4 Press 1 to save settings exit Set up mode and return to operational modes 6 Error Messages When zeroing if the error message E32 appears on the instrument display signifying that the instrument reading is beyond the zeroing range of 130 7 Care and Maintenance When the Aquant is not being used then do the following Store the Aquant in the carry case provided with the kit in a stable and dry environment Remove the battery if the Aquant will not be used for extended period of time Replace the battery when the low battery symbol appears on the display The information contained in this leaflet is given in good faith As the method of use of the instrument and its accessories and the interpretation of the readings are beyond the control of the manufacturers they cannot accept responsibility for any loss consequential or otherwise resulting from its use USA 1100 Technology Park Drive Billerica MA 01821 4111 Web www gesensing com protimeterproducts Ireland Sensing House Shannon Free Zone East Shannon County Clare Web www gesensing com protimeterproducts Protimeter Aquant is a registered trademark of GE Page 4 GE Protimeter Aquant