1. 9 6 Installation Preparation A Flue Damper e sees 10 B Chimney Rel e a a 10 C Gas TEE 10 D Hearth or Hearth 5 10 E Fireplace Conversion Notice 10 F Remote Control 10 7 Installing Vent Pipe and Appliance A Venting Components 11 B Connecting Vent 11 C Placing Securing and Leveling the Appliance 13 D Installing Adaptor and Termination Cap 14 8 Gas Information A Fuel Conversions e B Gas Gas Connection 22 12 ssi I deme rb as 9 Electrical Information A Wiring the B Junction Box C Installation for Fan 10 Finishing A Mantel 11 Appliance Setup Remove Shipping Clean the ACCOSSOLIBS i ped eee m e aad espe ovs Ember Placement NEEN ly ete Positioning tlie Lgs sere NES E dE Glass Air Shutter Setting o0mmocommsrm 12 Operating Instructions Before Lighting
2. Lighting Appliance Check Pilot Flame Appearance After Appliance is Frequently Asked Questions 13 Troubleshooting A Standing Pilot Ignition System 14 Maintaining and Servicing Appliance A Maintenance 15 Reference Materials Appliance Dimension Vent Kits Service Parts List Limited Lifetime Warranty Contact Information moog r Contains updated information Quadra Fire QVI 25FB S 2031 910 Rev D 3 08 Listing and Code Approvals A Appliance Certification MODELS QVI 25FB S LABORATORY Underwriters Laboratories Inc UL TYPE Vented Gas Appliance Heaters STANDARD ANSI Z21 88 2002 CSA2 33 M2003 UL307B This product is listed to ANSI standards for Vented Gas Appliance Heaters and applicable sections of Gas Burn ing Heating Appliances for Manufactured Homes and Recreational Vehicles and Gas Fired Appliances for Use at High Altitudes NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE This appliance is tested and approved as either supplemen tal room heat or as a decorative appliance It shoul
3. party responsible for use and operation A WARNING HOT SURFACES Glass and other surfaces are hot during operation AND cool down Hot glass will cause burns DO NOT touch glass until it is cooled NEVER allow children to touch glass Keep children away CAREFULLY SUPERVISE children in same room as fireplace Alert children and adults to hazards of high temperatures High temperatures may ignite clothing or other flammable materials Keep clothing furniture draperies and other flammable materials away This appliance has been supplied with an integral barrier to prevent direct contact with the fixed glass panel DO NOT operate the appliance with the barrier removed Contact your dealer or Hearth amp Home Technologies if the barrier is not present or help is needed to properly install one In the Commonwealth of Massachusetts installation must be performed by a licensed plumber or gas fitter a CO detector shall be installed in the room where the appliance is installed Installation and service of this appliance should be performed by qualified personnel Hearth amp Home Technologies suggests NFI certified or factory trained professionals or technicians supervised by an certified professional Quadra Fire QVI 25FB S 2031 910 Rev D 3 08 1 Read this manual before installing or operating this appliance Please retain this owner s manual for future
4. ON OFF SWITCH o o OPTIONAL WALL SWITCH THERMOSTAT OR REMOTE Figure 9 1 Standing Pilot Ignition Wiring Diagram Quadra Fire QVI 25FB S 2031 910 Rev D 3 08 17 Junction Box Installation C Installation for Fan Optional On units already installed removal of decorative front surround and gas insert is required pw Detach flexible liner from back of unit if insert is installed INSERT RELIEF AROUND CORD IN THIS END FROM OUTSIDE OF UNIT FEED PLUG THROUGH HOLE Remove the four screws on the cover plate see Figure 9 3 RUBBER COVER GROMMETS PLATE Figure 9 2 Junction box installation GROUND WIRE Figure 9 3 Optional Accessories Connecting the electrical junction box is required if using a blower or remote Bend up the tabs on the base pan see Figure 9 4 Place the blower in between the bend up tabs Plug the cord into a convenient outlet 2 Install wire the blower per instruction shipped with e An electrician may install an outlet box inside the fan fireplace Place the outlet in the lower back corner of the fireplace The ground wire of the fan can clip on the side of the base pan Must use cord supplied Reinstall the cover plate back on the unit Make sure the fan does not make contact with the back wall to prevent CAUTION noise from vibration Label all wires prior to disconne
5. Additional service part numbers appear on following page NGKS FBZC LPKS FBZC 2103 116 2103 117 230 1570 230 1520 mE E E Ha EN E E HEN mE HS Hd E EE 36 Quadra Fire QVI 25FB S 2031 910 Rev D 3 08 JADRA FIRE Service Parts QVI 25FB S UADR A a R Valve Assembly Parts List Beginning Manufacturing Date Oct 2007 Ending Manufacturing Date Valve Assembly IMPORTANT THIS IS DATED INFORMATION When requesting service or replacement parts for your appliance please provide model number and serial number All parts listed Stocked in this manual may be ordered from an authorized dealer at Depot PlotAssembly NG pae Y Plot Assembly LP Lane Y Orifice NG 368 ses Gas v Piezo Ignitor ess Valve Bracke 83040 MEE S lt lt lt lt lt Valve NG 230 0710 Valve LP 230 0720 302 320A Flex Ball Valve Assembly Quadra Fire QVI 25FB S 2031 910 Rev D 3 08 37 D Limited Lifetime Warranty 38 Lifetime Warranty LIMITED LIFETIME WARRANTY The Hearth amp Home Technologies limited Lifetime Warranty guarantees that the following components will work as designed for the lifetime of the stove or Hearth amp Home Technologies will repair or replace them These items include but are not limited to steel and cast iron components all gas burners gas logs combustion chambers
6. Improper installation adjustment al teration service or maintenance can cause injury or property damage Re fer to the owner s information manual provided with this appliance This appliance needs fresh air for safe operation and must be installed so there are provisions for adequate combustion and ventilation air If not installed operated and main tained in accordance with the man ufacturer s instructions this product could expose you to substances in fuel or fuel combustion which are known to the State of California to cause can cer birth defects or other reproduc tive harm Keep burner and control compartment clean See installation and operating instructions accompanying appliance f you cannot reach your gas sup plier call the fire department Use only your hand to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to re pair it call a qualified service tech nician Force or attempted repair may result in a fire or explosion Do not use this appliance if any part has been under water Imme diately call a qualified service tech nician to inspect the appliance and to replace any part of the control System and any gas control which has been under water CAUTION Hot while in operation Do not touch Keep children clothing furniture gaso line and other liquids having flammable vapors away Do not operate the appliance w
7. 377 mm S INLET GA 5 9 16 in GAS BALL VALVE NOT SHOWN Location Inches Milimeters 8 ome o xa m Figure 15 1 Appliance Dimensions Quadra Fire QVI 25FB S 2031 910 Rev D 3 08 33 Vent Kits Components Direct Vent Flex Liner Kits see Figure 15 2 LINK DV 30B or LINK DV 30 Masonry 3 inch flex liner kit Expands to 30 feet Includes two liners termination cap flashing and link adapter LINK DV4 30B or LINK DV4 30 Masonry 3 inch flex liner kit Expands to 30 feet and 4 inches respectively Includes two liners termination cap flashing and link adapter LINK DV 30B LINK DV 30 SVRLINK ADP LINK DV4 30B LINK DV4 30 Figure 15 2 Direct Vent Flex Liner Kits Direct Vent Flex Liner Accessory Kits see Figure 15 3 Flash Damp Zero clearance damper flashing kit for use with LINK DV 30B or LINK DV4 30B liner kits LINK ZC ADP Zero clearance chimney adapter SVRLINK ADP Adapter kit colinear to coaxial 3 inches included in above kits FLEX3 30 One 3 inch flexible liner expands to 30 feet FLEX3 30 2 Two 3 inch flexible liners expands to 30 feet each FLEX3 CNCT FLEX CNCT Connector kit 3 inch liner to 3 inch liner Figure 15 3 Direct Vent Flex Liner Accessory Kits one connector per kit 34 Quadra Fire QVI 25FB S
8. Model QVI 25FB S QUADRA FIRE Important operating and maintenance instructions included A WARNING If the information in these instructions is not followed exactly a fire or explosion may result causing property damage personal injury or death Do not store or use gasoline or other flam mable vapors and liquids in the vicinity of this or any other appliance e What to do if you smell gas Do not try to light any appliance Do not touch any electrical switch Do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas suppli er s instructions f you cannot reach your gas supplier call the fire department nstallation and service must be performed by a qualified installer service agency or the gas supplier This appliance may be installed as an OEM installation in manufactured home USA only or mobile home and must be installed in accordance with the manufacturer s instructions and the manufactured home construction and safety standard Title 24 CFR Part 3280 or Standard for Installation in Mobile Homes CAN CSA Z240MH This appliance is only for use with the type s of gas indicated on the rating plate CAUTION DO NOT DISCARD THIS MANUAL e Read understand and follow Leave this manual with these instructions for safe installation and operation Owner s Manual Installation and Operation GAS FIRED
9. Disconnect gas supply piping BEFORE pressure testing gas line at test pressures above 1 2 psig Close the manual shutoff valve BEFORE pressure testing gas line at test pressures equal to or less than 1 2 psig A WARNING Verify inlet pressures High pressure may cause overfire condition Low pressure may cause explosion Verify minimum pressures when other household gas appliances are operating Install regulator upstream of valve if line pressure is greater than 1 2 psig Pressure requirements for appliance are shown in the table below Minimum pressures must be met when other household gas appliances are operating NaturalGas Propane T 5 0 inches 11 0 inches Minimum inlet pressure deg W C 14 0 inches 14 0 inches Maximum inlet gas pressure W C W C 5 inch 10 0 inch Manifold pressure Dantes W C W C C Gas Connection Note Have the gas supply line installed in accordance with local building codes if any If not follow ANSI 223 1 Installation should be done by a qualified installer approved and or licensed as required by the locality In the Commonwealth of Massachusetts installation must be performed by a licensed plumber or gas fitter NOTE A listed and Commonwealth of Massachusetts ap proved 1 2 inch 13 mm T handle manual shut off valve and flexible gas connector are connected to the 1 2 inch 13 mm control valve inlet If substituting for these components
10. please consult local codes for compliance Refer to Section 15 for location of gas line access in ap pliance NOTE Gas line may be run from either side of the appliance provided the hole in the outer wrap does NOT exceed 2 1 2 inches in diameter and does not penetrate the firebox WARNING Gas Leak Risk Support control when attaching pipe to prevent bending gas line NOTE The gap between supply piping and gas access hole may be caulked with high temperature caulk or stuffed with non combustible unfaced insulation to prevent cold air infiltration Ensure that gas line does not come in contact with outer wrap of appliance Follow local codes Incoming gas line should be piped into the valve compartment and connected to the 1 2 inch connection on the manual shutoff valve Check all fittings and connections of appliance which may have loosened during shipping Quadra Fire QVI 25FB S 2031 910 Rev D 3 08 15 16 A WARNING Fire or Explosion Hazard Gas buildup during line purge may ignite Purge should be performed by qualified technician Ensure adequate ventilation Ensure there are no ignition sources such as sparks or open flames A small amount of air will be in the gas supply lines When first lighting appliance it will take a short time for air to purge from lines When purging is complete the appliance will light and operate normally A WARNING CHECK FOR GAS LEAKS
11. 2031 910 Rev D 3 08 QUADRA IDE Service Parts List QVI 25FB S Service Parts Diagram Beginning Manufacturing Date Oct 2007 Ending Manufacturing Date Win Y Part number list on following page Quadra Fire QVI 25FB S 2031 910 Rev D 3 08 35 Service Parts QVI 25FB S IMPORTANT THIS IS DATED INFORMATION When requesting service or replacement parts for your appliance please provide model number and serial number All parts listed z Stocked in this manual may be ordered from an authorized dealer at Depot Lane y osa Pa oeo eo a s tgs Lesen N N 5 tgs 6 is waow O 7 T acess Piae e Slide Piate assembly T 29280 Bmekg O N Y 12 Bumer Droppa 299164 n 318 Grate Assembly TOO Surround Mount Right Surround Mount Left Glass Latch Assembly Right Glass Latch Assembly Left zizi iz iz izizi izi izizi zi izi izizi Junction Box Wiring Assembly Blower Assembly Optional Vent Pipe Assembly Mineral Wool Vermiculite Embers fT LJ LJ Thermocouple Le Pilot tube MEM Patch Kit EE Conversion Kit NG MEE Conversion Kit LP EE LJ a LJ
12. heat exchanger systems stainless steel firebox components plating doors glass damaged by thermal breakage steel baffle supports steel and ceramic baffles and manifold tubes Labor is for the first five years THREE YEAR WARRANTY Our pellet firepots are covered under Hearth amp Home Technologies three year warranty program Labor is for 3 years TWO YEAR WARRANTY All electrical components such as but not limited to blowers wiring vacuum switches speed controls control boxes thermodisc switches pilot assembly gas valves thermostats and remotes are covered under Hearth amp Home Technologies two year warranty program Effective April 2005 igniters are also covered under the two year warranty Labor is for two years ONE YEAR WARRANTY Porcelain and Powder Coat finishes are warranted against manufacturer defects for one year Labor to repair or replace these parts is covered for one year reimbursed per our warranty service fee schedule CONDITIONS This warranty is non transferable and is made to the original retail purchaser only provided that the purchase was made through an authorized dealer of Hearth amp Home Technologies It must be installed and operated at all times in accordance with the Installation and Operating Instructions furnished with this product as well as any applicable local and national codes Any alteration willful abuse accident or misuse of the product shall nullify this warranty Labor to repair or rep
13. period it is recommended that some windows in the house be opened for air circulation This will help avoid setting off smoke detectors and help eliminate any odors associated with the appliance s initial burning Quadra Fire QVI 25FB S 2031 910 Rev D 3 08 27 A WARNING CAUTION Fire Risk Smoke and odors released during initial operation High Temperatures Open windows for air circulation Leave room during initial operation Smoke may set off smoke detectors Smoke and odors may be irritating to sensitive individuals Keep combustible household items away from appliance Do NOT obstruct combustion and ventilation air Do NOT place combustible items on top of or in front of appliance Keep furniture draperies away from appliance WARNING Fire Hazard CAUTION ser vapors and Ius dear aj appliance Do NOT store flammable materials in the appliance s vicinity Do NOT use gasoline lantern fuel kerosene charcoal lighter fluid or similar liquids in this appliance Combustible materials may ignite Prevent accidental appliance operation when not attended Unplug or remove batteries from remote control if absent or if appliance will not be used for an extended period of time Property damage possible from elevated temperatures E Frequently Asked Questions SOLUTIONS This is a result of gas combustion and temperature variations As the appliance warms this con
14. 340 705 Place log 5 across log 1 and log 3 in the grooved out areas as shown LOG 6 SRV740 707 Place log 6 across log 1 and log 3 in the grooved out areas as shown F Glass Assembly c WARNING Handle glass doors with care Inspect the gasket to ensure it is undamaged Inspect the glass for cracks chips or scratches Do NOT strike slam or scratch glass D GLASS ASSEMBLY PULL TO RELEASE LEFT SIDE Do NOT operate appliance with glass door removed cracked broken or scratched Replace glass door assembly as a complete appliance GLASS LATCH gt Removing Glass Assembly There are two glass latches on the left side of glass as Figure 11 2 Glass Assembly sembly and two glass latches on the right side To release glass assembly pull latch forward and allow G Air Shutter Setting to retract away from glass assembly y Optimal flame appearance is dependent on the air shutter Remove glass assembly after all four latches have been setting Adjustments should be made by a qualified released see Figure 11 2 technician alsssssembly Dn P ek Replace the glass door on the appliance Fasten the latches 7 16 Full Open on the glass frame 24 Quadra Fire QVI 25FB S 2031 910 Rev D 3 08 1 Operating Instructions A Before Lighting Appliance This appliance has a Standing Pilot Ignition WARNING e e e Sie HOT SURFACES Before operatin
15. Explosion Risk Fire Risk Asphyxiation Risk Check all fittings and connections Do not use open flame Afterthe gas line installation is complete all connections must be tightened and checked for leaks with a commercially available non corrosive leak check solution Be sure to rinse off all leak check solution following testing Fittings and connections may have loosened during shipping and handling A WARNING Fire hazard Do NOT change the valve settings This valve has been preset at the factory Changing valve settings may result in fire hazard or bodily injury HIGH ALTITUDE INSTALLATIONS U L Listed gas appliances are tested and approved without requiring changes for elevations from 0 to 2000 feet in the U S A and Canada Wheninstalling this appliance at an elevation above 2000 feet it may be necessary to decrease the input rating by changing the existing burner orifice to a smaller size Input rate should be reduced by 4 for each 1000 feet above a 2000 foot elevation in the U S A or 1096 for elevations between 2000 and 4500 feet in Canada If the heating value of the gas has been reduced these rules do not apply To identify the proper orifice size check with the local gas utility If installing this appliance at an elevation above 4500 feet in Canada check with local authorities Quadra Fire QVI 25FB S 2031 910 Rev D 3 08 Electrical Information A Wiring the Applian
16. LET 5 9 16 in GAS BALL VALVE NOT SHOWN 784 651 81 9 1 3 19 1 2 495 NOTE If exhaust collar on insert and fireplace damper do not line up add 4 inches 102 mm to minimum fireplace height for bends in vent pipe Figure 3 1 Fireplace Opening 6 Quadra Fire QVI 25FB S 2031 910 Rev D 3 08 Clearances A WARNING Fire Risk Odor Risk Clearance to combustible material under the insert is 1 4 inch 0 6 cm Use leveling legs to raise insert minimum 1 4 inch above combustible material or outer wrap of factory built firebox WARNING Fire Risk Locate and install appliance to all clearance specifications in manual MANTEL Il Il CE So 12 in MAX t V TOP OF UNIT Figure 3 2 Clearances to Mantels or other Combustibles above Appliance Quadra Fire QVI 25FB S 2031 910 Rev D 3 08 Termination Locations A Vent Termination Minimum Clearances A WARNING Figure 4 1 specifies minimum vent heights for various pitched roofs Fire Risk Asphyxiation Risk Terminations MUST meet minimum clearances Exhaust gases are hot Nearby vents may draw fumes into house HORIZONTAL OVERHANG 20 INCHES MIN VERTICAL WALL LOWEST DISCHARGE OPENING GAS DIRECT VENT TERMINATION CAP L ROOF PITCH IS X 12 H MIN MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING Roo
17. NOT allow vent to sag below connection point to appliance Quadra Fire QVI 25FB S 2031 910 Rev D 3 08 13 Installing Adaptor and Termination For installation of termination cap see minimum vent heights for various pitched roofs see Figure 7 2 Sharp Edges To install adaptor see Figure 7 3 20 INCHES MIN WALL HORIZONTAL OVERHANG VERTICAL LOWEST DISCHARGE OPENING GAS DIRECT VENT TERMINATION CAP Roof Pitch H Min Ft Flatito 6 12 s 1 0 Over 6 12 to 7 12 1 25 Over 7 12 to 8 12 1 5 Over 8 12 to 9 12 2 07 Over 9 12 to 10 12 2 5 Over 10 12 to 11 12 3 25 ROOF PITCH IS X 12 H MIN MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING Roof Pitch H Min Ft Over 11 12 to 12 12 4 0 Over 12 12 to 14 12 5 0 Over 14 12 to 16 12 6 0 Over 16 12 to 18 12 7 0 Over 18 12 to 20 12 7 5 Over 20 12 to 21 12 8 0 Wear protective gloves and safety w glasses during installation Damper Flashing Kit Optional For use with LINK DV4 30B Liner Kit Note Damper may have to be removed to use this kit Run flex liners through 3 holes in damper flashing Attach damper flashing to firebox roof with self tapping screws included in kit CLASS A PIPE 3 foot minimum in snow regions Figure 7 2 Minimum Height from Roof to Lowest Discharge Opening Figure 7 3 Not
18. abs see Figure 7 1 and secure with 8 screw Level the appliance from side to side and front to back If necessary use the leveling legs included with the manual bag to set each corner of the base Position any excess flexible vent pipe back up into chimney without sagging Twist and push flex vent together to shorten Install fiberglass insulation pieces to back face of surround Attach surround Follow instructions accompanying surround Push insert so that surround becomes tight against face of fireplace A WARNING Fire Risk Only an approved Hearth amp Home Technologies surround may be used to cover integral grills on solid fuel burning fireplaces No other components such as shrouds sheet metal plates etc may be used to seal off vents WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury WARNING Explosion Risk Combustion Fume Risk Connect vent sections per installation instructions The 3 foot section of stainless steel flexible pipe MUST be attached directly to the exhaust collar on the collar slide plate Connect exhaust vent pipe ONLY to exhaust starting collar and termination cap center collar Connect inlet air vent ONLY to inlet air collar on appliance and either the termination cap inlet air collar OR terminate within chimney Do
19. arances to Mantels or other Combustibles above Appliance 20 Quadra Fire QVI 25FB S 2031 910 Rev D 3 08 1 Appliance Setup A Remove Shipping Materials Remove shipping materials from inside or underneath the firebox B Clean the Appliance Clean vacuum any sawdust that may have accumulated inside the firebox or underneath in the control cavity C Accessories Install approved accessories per instructions included with accessories See Service Parts List for appropriate accessories A WARNING Shock or fire risk Use ONLY optional accessories approved for this appliance Using non listed accessories voids warranty Using non listed accessories may result in a safety hazard Only Hearth amp Home Technologies approved accessories may be used safely D Ember Placement WARNING Explosion Risk Follow ember placement instructions in manual Do NOT place embers directly over burner ports Replace ember material annually Improperly placed embers interferes with proper burner operation Placing the Ember Material Ember material is shipped with this gas appliance To place the ember material Embers CANNOT be placed directly over ports When placing Glowing Embers onto the burner care should be taken so that the ports are not covered Place the dime size ember pieces near port holes in burner top sides and front see Figure 11 1 Failure to follow this procedu
20. ce Appliance Requirements This appliance DOES NOT require 110 120 VAC to Note Electrical wiring must be installed by a licensed operate electrician It is recommended that a 110 VAC junction box be connected for use with fan or remote control See Figure Note This appliance must be electrically wired and grounded 9 2 for junction box wiring in accordance with local codes or in the absence of local codes with National Electric Code ANSI NFPA 70 latest edition or the Canadian Electric Code CSA C221 1 A WARNING Wire 110V to electrical junction box CAUTION Do NOT wire 110V to valve Do NOT wire 110V to wall switch Incorrect wiring will damage millivolt valves Incorrect wiring will override IPI safety lockout and may cause explosion Prevent accidental appliance operation when not attended Unplug or remove batteries from remote control if absent or if appliance will not be used for an extended period of time Property damage possible from elevated temperatures ON OFF Switch An ON OFF switch is included with the decorative surround decorative front and should attached to surround facing See Installation instructions for remote control f desired an additional wall switch or thermostat may be added to system as shown in Figure 9 1 STANDING REMOTE SWITCH f PIGTAIL
21. ckwise to increase pilot flame size Make small adjustments PILOT ADJUSTMENT Figure 12 2 Adjustments Do NOT turn adjustment screw counter clockwise too far as it will come out of the valve allowing gas to escape Replace cap screw and seal to prevent gas leaks Check for gas leaks after tightening D After Appliance is Lit WARNING Glass door must be in place when appliance is operating Risk of Combustion Fumes Fire Do NOT operate appliance with glass door removed Open viewing glass for servicing only Glass door MUST be in place and sealed before operating appliance Only use glass door certified for use with appliance Glass replacement should be done by qualified technician Initial Break in Procedure When you light the appliance you may notice that it pro duces heat which does have an associated odor or smell If you feel this odor is excessive it may require the initial three to four hour continuous burn on high followed by a second burn up to 12 hours to fully drive off any odor from paint and lubricants used in the manufacturing process Condensation of the glass is normal Note The appliance should be run three to four hours on the initial start up Turn it off and let it cool completely Remove and clean the glass Replace the glass and run the appliance for an additional 12 hours This will help to cure the products used in the paint and logs During this break in
22. codes and regulations Consult insurance carrier local building fire officials or authorities having jurisdiction about restrictions installation inspection and permits Quadra Fire gas inserts are designed for recessed installa tions into solid fuel masonry or factory built non combustible fireplaces that have been installed in accordance with the National Provincial State and local building codes Prior to installing the gas insert Have the chimney and adjacent structure inspected and cleaned by qualified professionals Hearth amp Home Technologies recommends that NFI or CSIA certified professionals or technicians under the direction of certi fied professionals conduct a minimum of a NFPA 211 Level 2 inspection of the chimney Replace component parts of the chimney and fireplace as specified by the professionals Ensure all joints are properly engaged and the chimney is properly secured When planning an appliance installation it s necessary to determine the following information before installing Minimum fireplace size See Section 3 A Gas supply piping Electrical wiring Finishing details Existing mantel projections See Section 10 Whether optional accessories devices such as a fan wall switch or remote control are desired B Tools and Supplies Needed Before beginning the installation be sure that the following tools and building supplies are available Pliers Hi t
23. ction when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing WARNING Shock hazard Replace damaged wire with type 105 C rated wire Wire must have high temperature insulation 18 Quadra Fire QVI 25FB S 2031 910 Rev D 3 08 JUNCTION BOX SPEED CONTROL RHEOSTAT TEMPERATURE SENSOR SWITCH i D OUTLET OUTLET BEND UP TABS INSERT STUD THROUGH HOLE TEMP SWITCH AND SECURE WITH WING NUT BRACKET REMOTE RECEPTACLE JUNCTION BOX VARIABLE SPEED CONTROL BLK JI BLOWER RECEPTACLE d WHT BLK BLOWER TEMPERATURE GRN SENSOR SWITCH BLK NOTE If any of the original wire as supplied 110 120 VAC with the appliance must be replaced it must be replaced with type 105 crated wire NOTE Do NOT install blower if using operable Figure 9 4 Fan Wiring Diagram glass doors Quadra Fire QVI 25FB S 2031 910 Rev D 3 08 19 1 Finishing A Mantel Projections Figure 10 1 shows the minimum vertical and corresponding maximum horizontal dimensions of appliance mantels or other combustible projections above the top front edge of the appliance not the surround MANTEL N im 12 in MAX t S V TOP OF UNIT Figure 10 1 Cle
24. d not be factored as primary heat in residential heating calculations Note To assure top performance safety and efficiency inserts must be installed with an approved flue liner as per CAN CGA B 149 or National Fuel Gas Code ANSI 7223 and these instructions Note This installation must conform with local codes In the absence of local codes you must comply with the National Fuel Gas Code ANSI Z223 1 latest edition in the U S A and the CAN CGA B149 Installation Codes in Canada B BTU Specifications Maxi Mini Orifi Models pru E edd e U S or Canada BTU h ETUR DMS 29850 24 000 29 650 21 000 36 0 2000 FT QVI 25FB S NG US 27000 16 000 52 QVI25FB S LP CANADA 24 300 14 400 53 C High Altitude Installations U L Listed gas appliances are tested and approved with out requiring changes for elevations from 0 to 2000 feet in the U S A and Canada When installing this appliance at an elevation above 2000 feet it may be necessary to decrease the input rat ing by changing the existing burner orifice to a smaller size Input rate should be reduced by 4 for each 1000 feet above a 2000 foot elevation in the U S A or 1096 for elevations between 2000 and 4500 feet in Canada If the heating value of the gas has been reduced these rules do not apply To identify the proper orifice size check with the local gas utility If installing this appliance at an elevat
25. densation will disappear This is a result of normal operation and the flames will begin to yellow as the appliance is al lowed to burn for 20 to 40 minutes When first operated this appliance may release an odor for the first several hours This is Odor from appliance caused by the curing of the paint and the burning off of any oils remaining from manufacturing and might set off home smoke detectors Condensation on the glass This is a normal result of the curing process of the paint and logs Glass should be cleaned Film on the glass within 3 to 4 hours of initial burning to remove deposits left by oils from the manufacturing process A non abrasive cleaner such as gas fireplace glass cleaner may be necessary See your dealer Noise is caused by metal expanding and contracting as it heats up and cools down similar to Metallic noise the sound produced by a furnace or heating duct This noise does not affect the operation or longevity of the appliance Is it normal to see the pilot flame burn continually In a standing pilot system the pilot will always stay on 28 Quadra Fire QVI 25FB S 2031 910 Rev D 3 08 1 Troubleshooting With proper installation operation and maintenance your gas appliance will provide years of trouble free service If you do experience a problem this troubleshooting guide will assist a qualified service person in the diagnosis of a problem and the corrective action
26. e The LINK DV4 30B system REQUIRES this insulation To help eliminate cold air drafts it may be necessary to place non combustible insulation around the flues as they go though the damper Masonry LINK DV30B Installation LINK DV4 30B Installation Factory Built Wood Burning OPTIONAL LINK ZC ADPB TERMINATION FOR USE WITH CLASS A WOODBURNING PIPE EA 4 EXHAUST EXHAUST AIR AIR VENT PIPE VENT PIPE OR WARNING DO NOT BLOCK THIS PIPE END INLET AIR VENT PIPE Note Untwist the pipe while extending it to achieve full 30 length INLET AIR VENT PIPE Remove 18 inch x 18 inch flashing on cap by removing 3 screws Connect both the LINK ZC ADPB to Class A Pipe and the termination cap to the LINK ZC ADPB with the self tapping screws provided Figure 7 4 14 Quadra Fire QVI 25FB S 2031 910 Rev D 3 08 Gas Information A Fuel Conversions Before making gas connections ensure that appliance be ing installed is compatible with the available gas type Any natural or propane gas conversions necessary to meet the appliance and locality needs must be made by a qualified technician using Hearth amp Home Technologies specified and approved parts B Gas Pressures Proper input pressures are required for optimum appli ance performance Gas line sizing requirements need to be made following NFPA51 A WARNING Fire Risk Explosion Hazard High pressure will damage valve
27. e checkup at the beginning of each heating season A WARNING PS CAUTION Risk of injury or property damage Handle glass assembly with care Before servicing NOTE Clean glass after initial 3 4 hours operation Longer operation without cleaning glass may Turn off gas cause a permanent white film on glass Turn off electricity to appliance When cleaning glass door Disable remote control if one is present Ensure appliance is completely cooled After servicing Avoid striking scratching or slamming glass Do NOT use abrasive cleaners Use a hard water deposit glass cleaner on white film Replace any screen or barrier that was removed Do NOT clean glass when hot Reseal and reinstall any venting removed for servicing Turn off appliance after 3 4 hours of operation and ALLOW TO COOL Remove and clean glass assembly Replace glass assembly and operate appliance for additional 12 hours Refer to maintenance instructions A WARNING Inspect external vent cap regularly Condition of firebox Burner ignition and operation Burner air shutter adjustment aZ Ensure no debris blocks cap Gas connections and fittings Combustible materials blocking cap may ignite EE Restricted air flow affects burner operation A WARNING Annual inspection by qualified technician recommended Check Condition of doors surrounds and fronts Condition of glass glass ass
28. e chimney is properly secured F Remote Control The receiver for the remotes must be installed BETWEEN the base pan of the insert and the firebox of the wood burning fireplace see photo below EXISTING SIDE REFRACTORY REMOTE RECEIVER UNIT EXISTING BOTTOM OF FIREPLACE 4 10 Quadra Fire QVI 25FB S 2031 910 Rev D 3 08 d Installing Vent Pipe and Appliance A Venting Components Sharp Edges Wear protective gloves and safety glasses during installation The vertical vent termination system installed on this model includes One 3 foot section stainless steel flexible pipe included with insert One length of 3 inch flexible vent pipe for combustion air included with vent kit Flexible vent pipe for exhaust air included with vent kit One pipe to cap adaptor included with vent kit One vertical termination cap included with vent kit B Connecting Vent Pipe Reference instructions in the termination kit Install the 3 inch flexible vent pipe s down through the chimney Secure the exhaust flexible vent pipe to the 3 foot section stainless steel flexible vent pipe using the factory installed 3 inch collar in the stainless steel section of pipe see Figure 7 1 Use 3 screws to attach either a 4 foot or 30 foot section of inlet air vent to the inlet collar on the collar slide plate see Figure 7 1 NOTE The collar slide plate may be removed from appliance to aid instal
29. e contact your Quadra Fire dealer with any questions or concerns For the location of your nearest Quadra Fire dealer please visit www quadrafire com NOTES CAUTION DO NOT DISCARD THIS MANUAL Important operating Read understand and follow Leave this manual with and maintenance these instructions for safe party responsible for use instructions included installation and operation and operation This product may be covered by one or more of the following patents United States 4593510 4686807 4766876 4793322 4811534 5000162 5016609 5076254 5113843 5191877 5218953 5263471 5328356 5341794 5347983 5429495 5452708 5542407 5601073 5613487 5647340 5688568 5762062 5775408 5890485 5931661 5941237 5947112 5996575 6006743 6019099 6048195 6053165 6145502 6170481 6237588 6296474 6374822 6413079 6439226 6484712 6543698 6550687 6601579 6672860 6688302B2 6715724B2 6729551 6736133 6748940 6748942 6769426 6774802 6796302 6840261 6848441 6863064 6866205 6869278 6875012 6880275 6908039 6919884 D320652 D445174 D462436 Canada 1297749 2195264 2225408 2313972 Australia 780250 780403 1418504 or other U S and foreign patents pending Printed in U S A Copyright 2008 Quadra Fire QVI 25FB S 2031 910 Rev D 3 08 39
30. embly and glass seal Obstructions of combustion and ventilation air Condition of logs Clean Glass Air passageways grilles control compartment Burner burner ports Risk of Fire Delayed ignition or explosion Exposure to combustion fumes Odors Quadra Fire QVI 25FB S 2031 910 Rev D 3 08 31 Inspect Maintenance Tasks Doors Surrounds 1 Assess condition of screen and replace as necessary Recommend addition of screen if one is not present and Fronts 2 Inspect for scratches dents or other damage and repair as necessary 3 Verify no obstructions to airflow through the louvers 1 i ition Gasket Seal Glass Inspect gasket seal and its condition Pine and Glass 2 Inspect glass panels for scratches and nicks that can lead to breakage when exposed to heat 3 Confirm there is no damage to glass or glass frame Replace as necessary 4 Verify that latches engage properly clip studs are not stripped and glass attachment components are intact and operating properly Replace as necessary 5 Clean glass Replace glass assembly if severely coated with silicate deposits that cannot be removed Valve Compartment 1 Vacuum and wipe out dust cobwebs debris or pet hair Use caution when cleaning these areas Screw and Firebox Top tips that have penetrated the sheet metal are sharp and should be avoided EMEN 4 Verify maintenance of proper clearance to combustible house
31. emp caulking material Hammer Flat blade screwdriver Voltmeter Framing square Gloves Variable speed drill 1 4 Hex drive Safety glasses Manometer Phillips screwdriver Tape measure Non corrosive leak check solution 1 2 3 4 inch length 6 or 8 Self drilling screws C Inspect Appliance and Components A WARNING Y Inspect appliance and components for damage Damaged parts may impair safe operation Do NOT install damaged components Do NOT install incomplete components Do NOT install substitute components Report damaged parts to dealer Carefully remove the appliance and components from the packaging The vent system components surrounds and fronts are shipped in separate packages The fiber logs may be packaged separately and must be field installed Report to your dealer any parts damaged in shipment particularly the condition of the glass Read all of the instructions before starting the insta llation Follow these instructions carefully during the installation to ensure maximum safety and benefit WARNING y Hearth amp Home Technologies disclaims any responsibility for and the warranty will be voided by the following actions Installation and use of any damaged appliance or vent system component Modification of the appliance or vent system Installation other than as instructed by Hearth amp Home Technologies Improper positioning of the gas logs or the glass door Installati
32. f Pitch H Min Ft Fatto 6 12 rr ee eee tee deret 1 0 Over 612 to V een 1 25 Over 7 12 10 8 12 es 1 5 Over 8 12 t0 TA uentos 2 0 Over 92 16 10 12 edente 2 5 Over t0 12 to 11 12 uncis 3 25 Over 11 12 to 12 12 sse 4 0 OVER 12 12 to T4 cem 5 0 Over 14 12 to 16 12 6 0 Over 16 12 to 18 2 canes 7 0 Over 18 12 to 20 12 7 5 Qver 20 12 10 212 ces 8 0 8 foot minimum in snow regions Figure 4 1 Minimum height from roof to lowest discharge opening 8 Quadra Fire QVI 25FB S 2031 910 Rev D 3 08 Vent Information and Diagrams A Vent Table Key ander A WARNING The abbreviations listed in this vent table key are used in the vent diagrams Fire Hazard Explosion Risk Asphyxiation Risk Do NOT connect this gas appliance to a chimney flue serving a separate solid fuel or gas burning appliance e May impair safe operation of this appliance B Horizontal Venting or other appliances connected to the flue Horizontal venting is NOT allowed Vent this appliance directly outside Use separate vent system for this appliance Minimum Vertical Run Length 14 ft Maximum Vertical Run Length 50 ft C Measuring Standards Vertical measurements listed in the vent diagram Figure 5 1 were made using the following standard CAUTION Vertica
33. g this appliance have a qualified Glass and other surfaces are hot during technician operation AND cool down Remove all shipping materials from inside and or Hot glass will cause burns underneath the firebox DO NOT touch glass until it is cooled NEVER allow children to touch glass Keep children away CAREFULLY SUPERVISE children in same room as Check the wiring fireplace Alert children and adults to hazards of high temperatures Review proper placement of logs rockwool lava rock and vermiculite Check the air shutter adjustment High temperatures may ignite clothing or other flammable materials Keep clothing furniture draperies and other flammable Ensure that there are no gas leaks materials away Purge gas line with glass assembly removed See Section 8 Ensure that the glass is sealed and in the proper position This appliance has been supplied with an integral barrier Ensure that the flow of combustion and ventilation air is to prevent direct contact with the fixed glass panel DO not obstructed front grilles and vent caps NOT operate the appliance with the barrier removed Contact your dealer or Hearth amp Home Technologies if the barrier is not present or help is needed to properly install one WARNING M Fire Risk W Explosion Risk A WARNING Gas may build up while lighting pilot Remove glass assembly before lighting pilot Improper installation adjus
34. hold objects 1 ion 2 Replace appliance if firebox has been perforated Burner Ignition and 1 Verify burner is properly secured and aligned with pilot or igniter 2 Clean off burner top inspect for plugged ports corrosion or deterioration Replace burner if necessary 3 Replace ember materials with new dime size and shape pieces Do not block ports or obstruct lighting paths Inspect for paint condition warpage corrosion or perforation Sand and repaint as necessary 4 Check for smooth lighting and ignition carryover to all ports Verify there is no ignition delay 11 Verify millivolt output Replace as necessary Venting 1 Inspect venting for blockage or obstruction such as bird nests leaves etc 2 Confirm that termination cap remains clear and unobstructed by plants etc 3 Verify that termination cap clearance to subsequent construction building additions decks fences or sheds has been maintained 10 Inspect thermocouple thermopile or IPI sensor rod for soot corrosion and deterioration Clean with emery cloth or replace as required 32 Quadra Fire QVI 25FB S 2031 910 Rev D 3 08 1 Reference Materials A Appliance Dimension Diagram Dimensions are actual appliance dimensions Use for reference only For framing dimensions and clearances refer to Section 3 4 3 8 in 1 1 16 in 111 mm lt 27mm 3 5 8 in REF Two 2 13 16 in 92 mm EH e 3 7 16 in 87 mm 14 7 16 in
35. ion above 4500 feet in Canada check with local authorities A WARNING Do NOT use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water D Non Combustible Materials Specification Material which will not ignite and burn Such materials are those consisting entirely of steel iron brick tile concrete slate glass or plasters or any combination thereof Materials that are reported as passing ASTM E 136 Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750 C shall be considered non combustible materials E Combustible Materials Specification Materials made of or surfaced with wood compressed paper plant fibers plastics or other material that can ig nite and burn whether flame proofed or not or whether plastered or unplastered shall be considered combustible materials 4 Quadra Fire QVI 25FB S 2031 910 Rev D 3 08 2 Getting Started A Design and Installation Considerations Quadra Fire direct vent gas appliances are designed to operate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside No additional outside air source is required CAUTION Check building codes prior to installation Installation MUST comply with local regional state and national
36. ith panel s removed cracked or broken Replacement of the panel s should be done by a licensed or qualified service person NOT FOR USE WITH SOLID FUEL For use with natural gas and propane A conversion kit as supplied by the manufacturer shall be used to convert this appliance to the alternate fuel Also Certified for Installation in a Bedroom or a Bedsitting Room For assistance or additional informa tion consult a qualified installer ser vice agency or the gas supplier For additional information on operating your Hearth amp Home Technologies fireplace please refer to www fireplaces com 26 INSTRUCTIONS Turn off all electric power to the appliance Push in gas control knob slightly and turn clockwise 9 7 Nx to OFF o ol 9 NOTE Knob cannot be turned from PILOT to OFF unless knob is pushed in slightly Do not force 3 Wait five 5 minutes to clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the Safety Informa tion located on the left side of this label If you don t smell gas go to next step 4 Find the pilot The pilot is inside combustion chamber next to the main burner Turn knob on gas control counter clockwise 40 PILOT Push in control knob all the way and hold in Im mediately depress red or black piezo button It may require several depressions of the red or black
37. l terminations are measured to top of chimney ALL venit specifications MUST This product is tested and listed to these specifications Appliance performance will suffer if specifications are not followed TERMINATION CAP M i ub cc INLET AIR COLLAR EXHAUST COLLAR EXHAUST VENT PIPE 14 FT MINIMUM 50FT MAXIMUM 3 INCH COLLAR Factory installed to stainless steel section WARNING DO NOT BLOCK PIPE END WITH INSULATION OR ANY OTHER SEALING MATERIAL STAINLESS STEEL PIPE 3 FT MIN REQUIRED INCLUDED SEAL DAMPER AREA INLET AIR VENT PIPE COLLAR ATTACHMENT BRACKET Figure 5 1 Quadra Fire QVI 25FB S 2031 910 Rev 3 08 9 Installation Preparation Prepare the existing solid fuel masonry or factory built non combustible firebox for installation A Flue Damper Fully lock the solid fuel fireplace s flue damper in the open position OR completely remove it B Chimney Ensure chimney is constructed of non combustible materials Ensure chimney is clean and in good working order Ensure that all chimney cleanouts fit properly to prevent air leakage into chimney C Gas Line Note If the factory built fireplace has no gas access hole provided an access hole of 1 inch 25 mm diameter or less may be drilled through the lower sides or bottom of the firebox in a proper workmanship like manner This access hole must be plugged with non combustible ins
38. lace items covered under the limited Lifetime Warranty will be covered for the first five years per our warranty service fee reimbursement schedule Parts covered under the limited Lifetime Warranty will be covered for the lifetime of the appliance up to a maximum of ten 10 years after Hearth amp Home Technologies discontinues the model and two 2 years for optional accessories Adjustments regular maintenance cleaning and temporary repairs do not qualify for a service call fee and will not be covered The replacement of consumer replaceable items and installation of upgraded component parts do not quality for a service call fee and will not be covered This limited Lifetime Warranty does not extend to or include surface finish on the appliance door gasketing glass gasketing glass firebrick pellet logs kaowool or other ceramic insulating materials It does not cover installation or operational related problems such as overfiring use of corrosive driftwood downdrafts or spillage caused by environmental conditions nearby trees buildings hilltops mountains inadequate venting or ventilation excessive offsets or negative air pressures caused by mechanical systems such as furnaces fans clothes dryers etc Any installation construction transportation or other related costs or expenses arising from defective part s repair replacement etc will not be covered by this warranty nor will Hearth amp Home Technologies assume responsibili
39. lation Seal opening between flex vent and chimney just above insert Unfaced fiberglass insulation may be used for this purpose Quadra Fire QVI 25FB S 2031 910 Rev D 3 08 11 LOCKING SLIDING PLATE LOCKING HANDLE Figure 7 1 Note Inspect for exhaust collar gasket to insure positive exhaust seal ALTERNATIVE INSTALLATION FOR VENTING THROUGH WOOD BURNING CLASS A PIPE TERMINATION CAP SQUARE FLASHING REMOVED INLET AIR VENT COLLAR LINK DV30 SHOWN OPTIONAL LINK ZC ADPB For Flashing Class A Pipe WOOD PIPE INLET AIR VENT PIPE STAINLESS STEEL 3 INCH ADAPTER FOR EXHAUST COLLAR MUST BE INSTALLED Quadra Fire QVI 25FB S 2031 910 Rev D 3 08 CUT AND BEND FLASHING AS NEEDED TO FIT CHIMNEY SEALANT ADHESIVE Figure 7 2 Trim chimney top plate to minimize excess overhang or bend over flue tile see Figure 7 2 Place 3 8 inch bead of 300 F silicone on flue tile top C Placing Securing and Leveling the Appliance Install insert without surround attached into existing fireplace while pulling collar slide plate forward Install gas line into hole provided on insert side If applicable install remote control wires into insert side see Section 6 F Secure collar slide plate to appliance by placing locking handle into position with locking t
40. n Inner vent pipe leaking exhaust gases back into Check venting system for damage Replace repair e System improperly assembled pipe sections c Glass too loose and air tight packet leaks in Replace glass panel assembly corners after usage d Bad thermopile or thermocouple Replace if necessary e Improper vent cap installation Check for proper installation and freedom from debris or blockage 6 Glass soots a Flame impingement Adjust the log set so that the flame does not exces sively impinge on it b Improper air shutter setting Adjust the air shutter located on the control panel c Debris around air shutter Inspect the opening at the base of the burner NO MA TERIAL SHOULD BE PLACED IN THIS OPENING 7 Flame burns blue a Insufficient oxygen being supplied Ensure that the vent cap is installed properly and free and lifts off burner of debris Ensure that the vent system joints are tight and have no leaks Ensure that no debris has been placed at the base of or in the area of the air holes in the center of the base pan beneath the burner Ensure that the glass is tightened properly on the unit particularly on top corners 30 Quadra Fire QVI 25FB S 2031 910 Rev D 3 08 14 Maintaining and Servicing Appliance A Maintenance Tasks Although the frequency of appliance servicing and maintenance will depend on use and the type of installation a qualified service technician should perform an applianc
41. ocouple Clean and or adjust the pilot for maximum flame impingement Ensure that the thermocouple connection at the gas valve is fully inserted and tight hand tighten plus 1 4 turn Disconnect the thermocouple from the valve place one millivolt meter lead wire on the tip of the thermcouple and the other meter lead wire on the thermocouple copper lead Start the pilot and hold the valve knob in If the millivolt reading is less than 15mV replace the thermocouple b Defective valve If the thermocouple is producing more than 15 millivolts replace faulty valve a ON OFF switch or wires Check the ON OFF switch and wires for proper connections Place defective the jumper wires across the terminals at the switch If the burner comes on replace the defective switch If the switch is OK place the jumper wires across the switch wires at the gas valve If the burner comes on the wires are faulty or connections are bad b Thermopile may not be gener If the pilot flame is not close enough physically to the thermopile ating sufficient millivoltage adjust the pilot flame Be sure the wire connections from the thermopile at the gas valve terminals are tight and that the thermopile is fully inserted into the pilot bracket Check the thermopile with a millivolt meter Take the reading at TH TP amp TP terminals of the gas valve The meter should read 325 millivolts minimum while holding the valve knob depressed in the pilot position wi
42. on 0 0inw c Col d eau Maximum Manifold Pressure Pression 0 0 in w c Col d eau Minimum Manifold Pressure Pression 0 0 in w c Col d eau Total Electrical Requirements 000Vac 00Hz less than 00 Amperes MADE IN USA Model Number INCANADA i ALTITUDE 0 0000 FT 0000 0000FT Modele Serial Number MAX INPUTBTUH 00 000 00 000 MIN INPUTBTUH 00 000 00 000 Serial ORIFICE SIZE HXXXXX Serie XXXXXXXX 2 Quadra Fire QVI 25FB S 2031 910 Rev D 3 08 Table of Contents 1 Listing and Code Approvals A Appliance 4 B BTU 4 C High Altitude 4 D Non Combustible Materials Specification 4 E Combustible Materials Specification 4 2 Getting Started A Design and Installation Considerations 5 B Tools and Supplies 5 C Inspect Appliance and 5 Fireplace Size Requirements A Minimum Fireplace Opening 6 Ee H 4 Termination Locations A Vent Termination Minimum Clearances 8 5 Vent Information and Diagrams A Vent Table Key eed eden de rs 9 B Horizontal Venting 0 0 e eee eee 9 C Measuring
43. on and or use of any component part not approved by Hearth amp Home Technologies Any such action may cause a fire hazard WARNING xi Keep appliance dry Mold or rust may cause odors Water may damage controls Quadra Fire QVI 25FB S 2031 910 Rev D 3 08 5 3 Fireplace Size Requirements A Minimum Fireplace Opening 7 A WARNING Minimum fireplace opening requirements are shown in Figure 3 1 Fire Risk Provide adequate clearance The firebrick refractory glass doors screen rails screen mesh and log grates can be removed from a factory built firebox in order to gain minimum gas insert To combustibles opening requirements For service access Locate appliance away from traffic areas Around air openings Any smoke shelves shields baffles and the metal floor of the unit may be removed from a factory built firebox if attached with mechanical fasteners If the appliance is NOTE For actual appliance dimensions refer to Section 15 placed on the base of the outer wrap a inch airspace must be provided between the insert and the floor of the outer wrap Cutting of any sheet metal parts of the fireplace in which the gas fireplace insert is to be installed is prohibited 7 20 3 8 29 3 4 in 18 15 16 in GAS IN
44. piezo button until PILOT lights If PILOT light does not light after 10 seconds return to step 3 Continue to hold the control knob in for about one minute after the pilot is lit Release knob and it will pop back out Pilot should remain lit If it goes out repeat steps 3 through 6 If knob does not pop up when released stop and im mediately call your service technician or gas supplier If the pilot will not stay lit after several tries turn the gas control knob to OFF and call your service technician or gas supplier 7 Turn gas control knob counterclockwise to ON To light Burner flip the on off switch to the ON position and close access grille Turn on all electric power to the appliance TOTURNOFF 1 GAS TO APPLIANCE Turn off all electric power to the appliance if service is to be performed Open control access panel Move switch to OFF position Pushin gas control knob slightly and turn clock wise lt x to OFF Do not force ntrol access panel Close co 464 9039 Quadra Fire QVI 25FB S 2031 910 Rev D 3 08 Check Pilot Flame Appearance Pilot flame must contact the thermocouple and thermopile for reliable appliance operation Pilot flame should be as shown in Figure 12 1 Figure 12 1 Proper Pilot Flame If adjustment is needed remove cap screw from gas valve using 1 8 inch standard screwdriver see Figure 12 2 Turn adjustment screw clo
45. re will likely cause lighting and sooting problems BURNER PAN PLACEMENT Figure 11 1 Placement of Embers Place Mystic Ember over burner surface and around base of burner Do not cover any burner port holes Use this material to give the appliance a realistic ash bed Save the remaining ember materials for use during appliance servicing The embers provided should be enough for 3 to 5 applications Quadra Fire QVI 25FB S 2031 910 Rev D 3 08 21 E Positioning the Logs LOG PLACEMENT Log Set Assembly LOGS 2031 INSTRUCTIONS Log Placement CAUTION Logs are fragile Carefully remove the logs from the packaging ml ili L Ze EE X N P zl I 2 KS AW WW ta W FIREBOX LEDGE LOG 1 SRV2032 701 Place log 1 on the firebox ledge as shown The front portion of the log should hang over the ledge as shown The log should be placed all the way back and in the center of the ledge 2031 700 22 Quadra Fire QVI 25FB S 2031 910 Rev D 3 08 LOG 3 SRV2032 703 Position log 3 by locating its slot over the tab on right front of the burner such that left end of log contacts log tab near the center of the burner LOG 4 SRV340 704 Place log 4 across log 1 and log 2 in the grooved out areas as shown Quadra Fire QVI 25FB S 2031 910 Rev D 3 08 23 is i gt A 1 NT E Compra itio o Some dO Pam 47 a a oq C LOG 5 SRV
46. reference Congratulations Congratulations on selecting a Quadra Fire gas appliance an elegant and clean alternative to wood burning appliances The Quadra Fire gas appliance you have selected is designed to provide the utmost in safety reliability and efficiency As the owner of a new appliance you ll want to read and carefully follow all of the instructions contained in this Owner s Manual Pay special attention to all Cautions and This Owner s Manual should be retained for future reference We suggest that you keep it with your other important documents and product manuals The information contained in this Owner s Manual unless noted otherwise applies to all models and gas control systems Your new Quadra Fire gas appliance will give you years of durable use and trouble free enjoyment Welcome to the Warnings Quadra Fire family of appliance products We recommend that you record the following pertinent information about your appliance Homeowner Reference Information Model Name Date purchased installed Serial Number Location on appliance Dealership purchased from Dealer Phone Notes Listing Label Information Location The model information regarding your specific appliance can be found on the rating plate usually located in the control area of the appliance This product may be covered by one or more of the following patents Nos produits sont couverts par un ou plusieur
47. s des brevets suivants United States 4593510 4686807 4766876 4793322 4811534 5000162 5016609 5076254 5113843 5191877 5218953 5263471 5328356 5341794 5347983 5429495 5452708 5542407 5601073 5613487 5647340 5688568 5762062 5775408 5890485 5931661 5941237 5947112 5996575 6006743 6019099 6048195 6053165 6145502 6170481 6237588 6296474 6374822 6413079 6439226 6484712 6543698 6550687 6601579 6672860 668830282 6715724B2 6729551 6736133 6748940 6748942 0320652 0445174 D462436 Canada 1297749 2195264 2225408 or other U S and foreign patents pending ou autres brevets americains et etrangers en attente GAS FIRED Quadra Fire a brand of Hearth amp Home Technologies Inc QUADRA IRE 1445 North Highway Colville WA 99114 E US Not for use with solid fuel Ne doit pas entre utilise avec un combustible solide LISTED Type of Gas Type of Gas Sorte De Gaz This appliance must be installed in accordance with local codes if any if not follow ANSI 2223 1 inthe USA or CAN CGA B149 installation codes Installer l appareil selon les codes ou reglements N ATU RAL GAS locaux ou en l absence de tels reglements selon les codes d installation CAN CGA B149 ANSI Z21XX XXXX CSA 2 XX MXX UL307B Gas and Electric Information Minimum Permissible Gas Supply for Purposes of Input Adjustment Approved Minimum De Gaz Acceptable 0 0 Col d eau Maximum Pressure Pressi
48. th the pilot lit and the ON OFF switch in the OFF position Replace the faulty thermopile if the reading is below the specified minimum With the pilot in the ON position disconnect the thermopile leads from the valve Take a reading at the thermopile leads The read ing should be 325 millivolts minimum Replace the thermopile if the reading is below the minimum Quadra Fire QVI 25FB S 2031 910 Rev D 3 08 29 Troubleshooting continued Symptom Possible Cause Corrective Action 3 Continued c Defective valve Turn the valve knob to the ON position Place the ON OFF switch in the ON position Check the millivolt meter a the thermopile terminals The millivolt meter should read greater than 125mV If the reading is ac ceptable and if the burner does not come on replace the gas valve d Plugged burner orifice Check the burner orifice for stoppage Remove stop page e Wall switch or wires are defective Follow the corrective action in Symptom and Pos sible Cause 1 a above Check the switch and wiring Replace where defective 4 Frequent pilot outage a Pilot flame may be too high or too low or blow Clean thermocouple and adjust the pilot flame for problem ing out high pressure causing pilot safety to drop maximum flame impingement Follow lighting instruc out tions carefully 5 The pilot and main a NoLP in tank Check the LP propane tank Refill the fuel tank burner extinguish while in operatio
49. tment alteration service or Replace glass assembly after lighting pilot maintenance can cause injury or property damage Refer to the owner s information manual provided with this appliance For assistance or additional information consult a qualified installer service agency or the gas supplier A WARNING Do NOT use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water Quadra Fire QVI 25FB S 2031 910 Rev D 3 08 25 Lighting Appliance Standing Pilot Ignition CT FoR YOUR SAFETY LLL LIGHTING READ BEFORE LIGHTING WARNING If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life A This appliance has a pilot which must be lighted by hand When lighting the pilot follow these in structions exactly BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions WARNING DO NOT CONNECT 110 VAC TO THE CONTROL VALVE
50. to be taken This troubleshooting guide can only be used by a qualified service technician A Standing Pilot Ignition System Symptom Possible Causes Corrective Action 1 After repeated triggering of the red or black piezo ignitor button the spark ignitor will not light the pilot 2 The pilot will not stay lit after carefully following the lighting instructions 3 The pilot is burning there is no burner flame the valve knob is in the ON position and the ON OFF switch is in the ON position a Defective ignitor Check the spark at the electrode and pilot If no spark and electrode wire is properly connected replace the ignitor b Defective pilot or misaligned Using match light the pilot If the pilot lights turn off the pilot and electrode spark at electrode trigger the red piezo ignitor button again If the pilot lights an im proper gas air mixture caused the bad lighting and a longer purge period is recommended If the pilot will not light ensure the gap at the electrode and pilot is one eighth 1 8 inch to have a strong spark If the gap is OK replace the pilot c No gas or low gas pressure Check the remote shut off valves from the fireplace Usually there is a valve near the gas main There can be more than one 1 valve between the fireplace and the main d No LP in tank Check the LP propane tank You may be out of fuel a Defective thermocouple Check that the pilot flame impinges on the therm
51. ty for them Further Hearth amp Home Technologies will not be responsible for any incidental indirect or consequential damages except as results in damage to the interior or exterior of the building in which this appliance is installed This limited Lifetime Warranty does not apply to the venting components hearth components or other accessories used in conjunction with the installation of this product not manufactured by Hearth amp Home Technologies This warranty is void if the stove has been overfired or operated in atmospheres contaminated by chlorine fluorine or other damaging chemicals the stove is subjected to prolonged periods of dampness or condensation or there is any damage to the stove or other components due to water or weather damage which is the result of but not limited to improper chimney or venting installation Hearth amp Home Technologies may at its discretion fully discharge all obligations with respect to this warranty by either repairing or replacing the unit or refunding the wholesale price of the defective part s This limited Lifetime Warranty is effective on all appliances sold after May 1 2002 and supersedes any and all warranties currently in existence 250 8620 Rev Quadra Fire QVI 25FB S 2031 910 Rev D 3 08 Contact Information QUADRA FIRE Quadra Fire a brand of Hearth amp Home Technologies Inc 20802 Kensington Boulevard Lakeville MN 55044 www quadrafire com Pleas
52. ulation after the gas supply line has been installed Install gas line into firebox cavity Check local codes and gas line sizing requirements following NFPA51 See Section 8 D Hearth or Hearth Extension A WARNING Fire Risk A hearth or hearth extension if present must comply with either of the following The solid fuel burning fireplace manufacturer s specification Local building codes required by authority having jurisdiction NFPA 211 E Fireplace Conversion Notice Permanently attach the label with the following warning to the inside lower back of the fireplace firebox into which the insert is being installed Silicone may be required to properly secure the label A WARNING Fire Risk This fireplace has been converted for use with a gas fireplace insert only and cannot be used for burning wood or solid fuels unless all original parts have been replaced and the fireplace re approved by the authority having jurisdiction Prior to installing the gas insert Have the chimney and adjacent structure inspected and cleaned by qualified professionals Hearth amp Home Technologies recommends that NFI or CSIA certified professionals or technicians under the direction of certi fied professionals conduct a minimum of a NFPA 211 Level 2 inspection of the chimney Replace component parts of the chimney and fireplace as specified by the professionals Ensure all joints are properly engaged and th