1. been disconnected from its fuel Supply natural gas line or LP gas LOCAL CODES Install and use heater with care Follow all local codes In the absence of local codes use the latest edition of The National Fuel Gas Code ANSZ223 1 also known as 54 Available from American National Standards Institute INC 1430 Broadway New York NY10018 National Fire Protection Association INC Battery march Park Quincy MA 02269 Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of control system and any gas control which has been under water IMPORTANT Installation of natural gas and LP should be done by a qualified installer service agency or gas supplier The appliance and its manual shutoff valve must be disconnected from the gas supply piping sys tem during any pressure testing of the system at test pressures in excess of 1 2 psig 3 5 This appliance must be isolated from the gas supply piping system by closing its manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 Installation LOGS LIST 600 PN7SOHYLA FIG 2 The LOG sets for PLEOOHYLA PN750HYLA PLOQOOHYLB PN750HYLB log 4 log 1 log 2 FIG The LOG sets for PL6Q0OHYLB PN750HYLB Installation continue Check to mak
2. campfire to the 1 2 steel piping making sure to clean the pipe threads and use Teflon tape or pipe dope FLEX LINE NOT SUPPLIED 5 Connect the 1 2 female X 3 8 male flare brass fitting to the 3 8 female brass flare fitting as sembled on the right side of the gas line of the right side of the campfire NOTE Brass to brassw connections do not require teflon tape or pipe dope Note show drawing of hard piping installation To Regualtor Connector Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition Young children should be carefully supervised when they are in the area of the appliance Never leave the appliance unattended during operation eClothing or other flammable materials should not be placed on or near the appliance O Any guard or other protective device removed for servicing the appliance must be replaced prior to operating the appliance O Installation and repair should be done by a quali fied service person The appliance should be in spected before use and at least annually by a quali fied service person More frequent cleaning may be required as necessary lt is imperative the con trol compartment burners and circulating air pas sageways of the appliance be kept clean O Inspect the fuel supply connection before each use of the appliance Storage of this appliance indoors is permissible only if it has
3. the ON OFF gas valve of the appliance to the incoming gas supply line See Figure 10 Make certain all gas connections are right Turn the ON OFF valve at the appliance slowly to the ON position Use a soap and water solution to test for leaks Fig 11 Natural gas burner assembly OPERATING HEATER Your campfire burener is build to operate with natural gas or build for LP gas This appliance is lit a piezo ignitor follow these instruc tions exactly when lighting the campfire BEFORE LIGHTING smell arround the appliance the appliance area for gas Be sure to smell to next to the ground as liquid propane gas heavier than air and will settle to the ground Follow adaptable lighting instructions Apply soap solu tion to all joints Bubbles forming indicates a leak Do not use a match or an open flame to detect leak Light heater after ensuring that no gas leak exists LIGHTING INSTRUCTIONS WARNING FOR YOUR SAFETY READ BEFOR LIGHTING 1 STOP Read the safety information above 2 Make sure manual shutoff valve is fully open 3 Press in and turn control knob clockwise 90 degree to the OFF position 4 Wait five 5 minutes to clear out any gas Then smell for gas around log set and near floor If you smell gas STOP Follow the safety information above If you don t smell gas go on to the next step 5 Turn control knob counterclockwise 90 degree to the PILOT position and press in Keep con
4. trol knob pressed in for five 5 seconds Note You may be running this log set for first time after hooking up to gas supply If so the control knob may need to be pressed in for 30 seconds This will allow air to bleed from the gas system 6 With control knob pressed in push down and re lease ignitor button This will light the pilot The pi lot is attached to the side of the front burner If needed keep pressing ignitor button until pilot lights NOTE If pilot does not stay lit contact a qualified service person or PRO COM s 800 on the back of this manual Until repairs are made light pilot with the piezo 7 Keep control knob pressed in for 30 seconds after lighting pilot After 30 seconds release control knob Note If pilot goes out repeat steps 3 through 7 If control knob does not pop up when released tact a qualified service person or PRO COM s 800 on the back of this manual 8 Turn control knob counterclockwise 4 Y 90 degree to the ON position Burner should light If burner does not light call a qualified service person or PRO COM s 800 on the back of this manual AX WARNING If you do not follow these in structions exactly a fire or explosion may result causing property damage personal in jury or loss of life TO TURN OFF GAS TO APPLIANCE Shutting Off Appliance 1 Turn control knob clockwisf Y the PILOT position 2 Press in and turn control knob clockwise 90 degrees t
5. 5 x25 20 1 4 Weight Lbs Stove 32 33 32 33 Shipping Weight 55 58 55 58 For purpose of shipment adjustment Minimum clearances Bottom This appliance may not be place on any combustible materials Top 8 2 4m Side walls around 48 inch 1220mm TROUBLESHOOTING OBSERVED PROBLEM POSSIBLE CAUSE REMEDY Burner does not light 1 Air in gas lines 1 Continue holding down control knob Repeat igniting operation until air is removed 2 Inlet gas pressure is too low 2 Check gas pressure 3 Gas supply turned off 3 Fully open gas supply 4 Air passageway on heater blocked 4 Check air passageway 5 Burner orifice clogged 5 Clean burner 6 Control knob not in ING ON position 6 control knob to ING ON position 7 Control knob not fully pressed in while 7 Press down control knob in ING ON position When ignitor buttons 1 ignitor electrode positioned wrong 1 Reposition ignitor pressed in there is no 2 Ignitor broken 2 Replace pilot spark at safety Pilot 3 Broken ignitor cable 3 Replace ignitor cable 4 ignitor electrode not connected to ignitor cable 4 Connect electrode to ignitor cable Burner fire does not last Damaged thermocouple 1 Replace thermocouple 2 Thermocouple electrode corrosion 2 Clean thermocouple electrode Damaged control valve 3 Replace control valve 4 Control knob not pressed long enough 4 After pilot lights keep control knob pressed in for 30 second
6. CLOSER THAN FORTY EIGHT 48 INCHES FROM ANY SIDE TO ANY COMBUSTIBLE CONSTRUCTION OR MATERIALS Location Your campfire can be installed on a flat stable surface away from any combustible materials or construction See Figure 13 Place unit on any level outdoor non combustible surface NOTE Do not place this appliance on grass or dirt area this may prevent proper venting HARD PIPING TO UNIT WITHOUT GAS PROXIMITY 1 TURN OFF THE GAS SUPPLY SYSTEM NOTE All gas connections except for brass to brass require the following Clean pipe threads using either a wire brush or steel wool Apply Teflon tape or pipe dope to the steel fittings before making any connection BE CAREFUL Make sure all gas connections are snug but not over tighten 2 Extend the gas supply system using1 2 black iron pipe from current house supply This may be ac complished by a teeing off or tapping into a con venient gas line connection installing the neces sary pipe for the distance required and then in stalling a manual valve at exterior house wall If pipe is to pass though a foundation or house wall make sure to re seal the area around the pipe with weather sealant 3 From manual valve extend piping to the campfire Location Continue Note If pipe is to be placed an underground trench check with local codes for required depth and mate rial construction 4 Connect the 3 8 male flare brass fitting furnished with
7. P RO COM OWNER S OPERATION AND INSTALLATION MANUAL PL600HYLA PL600HYLB 60 000BTU Hr PN750HYLA PN750HYLB 75 000BTU Hr Manually Controlled WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Shut off supply to the appliance Extenguish any open flames Immediately call your gas supplier Follow the gas supplier s instructions If you can not reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier IMPORTANT Read this owner s manual carefully and completely before trying to assemble operate or service this heater AAWARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage Read the installation operating and maintenance instructions thoroughly before installing or servicing this AX WARNING For Outdoor Use Only Do not use for cooking Save this manual for future reference Installer Leave this manual with customer 1 GENERAL INFORMATION These instructions are intended as a general guide and do not supersede national or local codes in anyway Authorities having jurisdiction
8. e sure you have the correct parts before 7 Install the No 1 log as indicated on base log Fix assembling the log on the bracket by the screw Logs 5 FIG 6 Caution Some of the steel edges may be sharp Please use caution when assembling the unit INSTALLATION INSTRUCTIONS 1 Remove log from inside the box Please note each log fits the number marked on foam package 2 Next remove campfire from box 3 You may use bricks or blocks to create your sur Fig 6 Install the LOG 1 round to place your campfire on 4 Make sure that the campfire is placed on a flat surface 5 Check the log piece FIG 4 8 Install the No 2 log as indicated on base log FIG 7 Fig 4 Check the log piece 6 Make sure that the logs were installed correctly Fig 7 install the LOG 2 FIG 5 Base logs are pre installed 9 Install the No 3 log as indicated on the base log FIG 8 Fig 8 install the LOG 3 Fig 5 Install and check the base logs Installation continue 11 install the No 4 log as indicated on the base FIG 9 Fig 9 Install the LOG 4 12 Install the No 5 Log as indicated on the base log FIG 10 FIG 10 Insatll the LOG 5 CONNECTING TO GAS SUPPLY Note Apply a mixture of liquid soap and water to all joints Do not use an open flame Bubbles forming show a leak Check all connections for leaks immediately FUEL REQUIREMENTS Natural gas models Connect
9. efects and or other reproductive harm This warning is issued pursuant to California Health Safety Code Sec 25249 1 While this appliance is not in use the gas must be turned off at the gas supply While this appliance is not in use it should be covered to protect it from weather and other adverse elements DO NOT ATTEMPT TO DISCONNECT THE GAS OR ANY GAS FITTING WHILE THIS APPLIANCE IS IN OPERATION Inspect the gas connections of this appliance prior to each use Do not operate the unit if there is a gas leak present Do not put anything flammable on or around or be neath the campfire NEVER Leave the campfire unattended while in operation NEVER Allow children to operate this appliance NEVER Lean over the campfire or place hand or fin gers on the screen cover or near flame NEVER Use liquid propane gas in a natural gas unit or natural gas in a liquid propane unit Gas conver sions SHOULD ONLY BE DONE BY A QUALIFIED SERVICE TECHNICIAN DO NOT use charcoal bri quettes or lighter fluid in any campfire Storage of this appliance indoors is permissible only if the gas is disconnected PROPER CLEARANCES FROM COMBUSTIBLE CON STRUCTION AND MATERIALS MUST BE MAINTAINED FROM ALL SIDES TOP AND BOTTOM OF THIS APPLIANCE THIS APPLIANCE SHOULD NEVER BE PLACED ON ANY COMBUSTIBLE SURFACE THIS APPLIANCE SHOULD NEVER BE PLACED UNDER ANY COMBUSTIBLE CONSTRUCTION OR MATERIALS THIS APPLIANCE SHOULD NEVER BE PLACED
10. erral information When calling PRO COM or your dealer have ready Your name Your address Model and serial numbers of your heater How heater was malfunctioning Type of gas used propane LP or natural gas Warranty card Usually we will ask you to return the defective part back to retail store PARTS NOT UNDER WARRANTY Contact authorized dealers of this product or Parts Central if they can t supply original replacement part s Call PRO COM s Parts Department at 1 877 886 5989 for referral information When calling PRO COM have ready e Model number of your heater eo The replacement part number ACCESSORIES HIGH ALTITUDE DERATE Purchase the accessories from your local dealer or the U S A Input BTU shall be derated 4 1 orifice rts Central ey cannot su ese ssorie ae size per 1000ft for above 2000ft In Canada input BTU call PRO COM s Sales Department at 1 877 886 5989 l shall be derated 10 2 orifice size at altitudes from for referral information You can also write to the ad 2000ft to 4500ft dress listed on the back page of this manual SPECIFICATIONS Model L600HYLA B PN750HYLA B Btu LP NG 60 000 75 000 Gas Type LP NG Ignition Piezo Piezo Inlet Gas Pressure In of water Maximum 14 10 5 Minimum 11 5 5 Dimensions Inches HxWxD Stove 17 3 4 x22 7 8 x18 1 8 17 3 4 x22 7 8 x18 1 8 Carton 15 x25 20 1 4 1
11. f part s required to restore this heater to proper operating condition and an allowance for labor when provided by a PRO COM Authorized Service Center Warranty part s MUST be obtained through authorized dealers of this product and or PRO COM who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not in original condition because of normal wear and tear or parts that fail or become damaged as a result of misuse accidents lack of proper maintenance or defects caused by improper installation Travel diagnostic cost labor transporta tion and any and all such other costs related to repairing a defective heater will be the responsibility of the owner FULLEXTENT ALLOWED BY THE LAW OF THE JURISDICTION THAT GOVERNS THE SALE OF THE PRODUCT THIS EXPRESS WAR RANTY EXCLUDES ANY ANDALL OTHER EXPRESSED WARRANTIESAND LIMITS THE DURATION OF ANY ANDALL IMPLIED WARRANTIES INCLUDINGWARRANTIESOF MERCHANTABILITYAND FITNESS FORAPARTICULARPURPOSE TOONE 1 YEARONALLCOMPONENTSFROM THE DATE OF FIRST PURCHASE NANJING PRO COM S LIABILITY IS HEREBY LIMITED TO THE PURCHASE PRICE OF THE PRODUCT AND NANJINGPRO COMSHALLNOT BELIABLE FORANY OTHERDAMAGESWHATSOEVERINCLUDINGINDIRECT ACCIDENTALORCONSEQUEN TIALDAMAGES S
12. gniter This system requires no matches batteries or other sources to light heater VALVE CONTROL SYSTEM This heater has a control valve to control the gas flow with the control valve you can chose the proper flame of the fire Option Screen For Your safety You may purchase the screen to maintain a clearance around the campfire CAUTION PLEASE DO NOT TOUCH SCREEN OR PLACE ANY OBJECTS ON SCREEN WHILE BURNER IS ON Children and adults should be alerted to the hazards of high surface temperatures and should stay away from SCREEN to avoid burns or clothing ignition W HAN a PAVO y Wh i d FIG 13 The screen 9 SERVICE INDICATIONS A hazardous condition may result if a heater has been modified or is not functioning properly When the heater is working properly 1 The flame is essentially yellow 2 There is no strong disagreeable odor eye burn ing or other physical discomfort 3 No smoke or soot exists internal or external to the campfire 4 No unplanned or unexplained shut down of the heater occur REPLACEMENT REPLACEMENT PARTS Note Use only original replacement parts This will protect your warranty coverage for parts replaced un der warranty PARTS UNDER WARRANTY Contact authorized dealers of this product If they can t supply original replacement part s call PRO COM s Technical Service Department at 1 877 886 5989 for ref
13. o OFF position 90 degrees to Shutting Off Burner Only pilot stays lit Turn control knob clockwise N 90 degrees to the PILOT position HIGH LOW 1 al PILOT IGN OFF IGNICIO N VALVULA CENTRAL Fig12 The operationg board MAINTENANCE AND STORAGE 1 Storage of an appliance indoors is permissible only if the gas supply system is disconnected and removed from the appliance 2 Have the heater inspected by qualified service man before each use or at least annually 3 Check the POL fitting for any damage before each use and replace if any damage is found 4 Spiders and insects can nest and live in outdoor appliances especially in the burners and orifices This will interrupt the normal flow of LP gas to the heater and can be a very dangerous situation Inspect for insect infiltration of burner orifice when one of the following occurs A The smell of gas along with predominating yel low tipping of the burner flames B Heater can not reach desired temperature C Uneven burner flow D Burner makes popping noises during normal use or shutdown 5 Adopt rainproof cover provided with the heater to avoid rust of heater when not in use PRODUCT FEATURES SAFETY PILOT The heater has a pilot with a safety shutoff system The safety pilot is a required feature for outdoor heaters It shuts off the heater if flame is extinguished by rough wind PIEZO IGNITION SYSTEM This heater has a piezo i
14. ome states do not allow a limitation on how long an implied warranty lasts or an exclusion or limitation of accidental or consequential damages the above limitation on implied warranties or exclusion or limitation on damages may not apply to you This warranty gives you specific legal right and you may also have other rights that vary from state to state For information about this warranty please write to NANJING PRO COM ELECTRIC APPLIANCE CO LTD 6 CHUANGYE ROAD HIGH NEW TECHNOLOGY amp DEVELOPMENT ZONE GREAT BRIDGE ROAD NORTH NANJING 210061 CHINA PatentPending PRO COM TOLL FREE NUMBER 1 877 886 5989 13
15. s 5 Thermocouple connection loose at control valve 5 tighten connection or replace thermocouple 6 Pilot flame not touching thermocouple 6 Contact qualified service man 10 PARTS LIST PL600HYLA PL600HYLB PN750HYLA PN750HYLB KEY PART DESCRIP TOM NUMBER III FR pa __ gt ___ __ a _ _ _ _ _ _ __ __ anar commen Rega 2 2 NRO 2 02 Regulator 1 ES A TEL ILLUSTRATED PARTS BREAKDOWN PL600HYLB PN750HYLA PN750HYLB WARRANTY INFOR ATION KEEPTHIS WARRANTY Model Serial No Date Purchased Always specify model and serial numbers when communicating with PRO COM We reserve the right to amend these specifications at any time without notice The only warranty applicable is our standard written warranty We make no other warranty expressed or implied LIMITED WARRANTY PRO COM OUTDOOR CAMPFIRE PRO COM warrants this product to be free from defects in materials and components for one 1 years from the date of first purchase provided that the product has been properly installed operated and maintained in accordance with all applicable instructions to make a claim under this warranty the Bill of Sale or cancelled check must be presented This warranty is extended only to the original retail purchaser This warranty covers the cost o
16. should be consulted before installation Installation and provision for combustion and ventilation air must confirm with the national Fuel Gas Code This campfire has been tested to and complies with IAS 4 96 1997 U S Requirements for Outdoor Gas Fireplace TABLE OF CONTENTS GENERAL ANFORMATION 2 SAFETY INFORMATION cia INSTALLATION E 5 OPERATING HEATER ni 7 MAINTENANCE AND STORAGE A a EES 8 PRODUCT FEATURES tada 9 SFE OIFIOATION aaa atada lia 10 TAOUBLESHOC TING trios Be 10 PARTES LIS Ta da AE 11 WARRANT A Io EEEE sae ase end A Liquid propane units are designed and certified for use only with house hold liquid propane supply period Do not use portable propane tanks of less than 100 165 Capacity LP units cannot be operated with 20 lb Propane tanks commonly used with portable liquid propane gas grills SAFETY INFORMATION THIS GAS APPLIANCE IS DESIGNED FOR OUTDOOR USE ONLY IT IS NOT INTENDED FOR INSTALLATION IN ANY BUIDING GARAGE OR ENCLOSED STRUCTION IT IS NOT INTENDED FOR INSTALLATION IN OR ON RECREATIONAL VEHICLES OR BOATS AX WARNING Follow all gas leak procedures in this manual prior to operation A WARNING Fuels used in gas fired appliances and the products of combustion of such fuels contain chemicals know to the State of California to cause cancer birth d
Download Pdf Manuals
Related Search
Related Contents
Partner Tech PT-6215 Pioneer SX-650 User's Manual BioDrain Grease & Waste Digester 50070250C F-GB-I-SK-E-D - Oleo-Mac LG Digital Signage - CNET Content Solutions CIS & CISM Installation, Operating & Maintenance Manual MANUAL DO USUÁRIO EXPRESSO.BA StarTech.com 5m (16 ft) White CL3 In-wall High Speed HDMI Cable - Ultra HD 4k x 2k HDMI Cable - HDMI to HDMI M/M Service Manual - Strumedical.com Copyright © All rights reserved.