Home

Pentair Small Underwater Pool Lights SunLite LTC User's Manual

image

Contents

1. 30 5 120V 250 Watts 05607 2030 30 9 1 05607 2050 50 15 2 05607 2100 100 30 5 INSTALLATION SunLite LTC Lamp Housing Installation Refer to Figure 1 below 4 CAUTION Burn hazard This light should never be energized while laying face down on the pool deck Installation of a 12 Volt transformer is required when installing the 12 Volt model of this light The transformer must be located at least 10 from the pool wall installed near a grounded 3 prong 120V GFCI protected outlet If you do not have a GFCI protected outlet have a qualified electrician install one Do not use a 3 prong adapter The adapter voids the grounding of the system Make connections in the conduit box be sure to fol low code requirements Connect the supply circuit grounding wire green green and yellow or bare copper to the green ground conductor from the light fixture Connect the line supply wire the black or hot wire to the black wire from the light fixture Connect the neutral white supply wire to the neutral white wire from the light fixture Coil the remaining cord in the back of the niche and place the lamp housing in the niche The mounting tab on the bottom of the lamp housing must be in the notch at the bottom of the niche Fasten the lamp housing into the niche with the captive leader screw at the top of the lamp housing use a No 2 Phillips screwdriver Tig
2. 0 Close the clamp ring fitting the other half over the same flanges 11 Swing the nut and screw into the slotted end of the clamp assembly Tighten this screw securely 20 inch pounds torque to insure good electrical bonding 12 To replace the lamp housing in the pool wall hook the bracket at the bottom of the niche and tighten the leader screw on the face ring of the lamp housing poene eee 5 Vv LAMP Note gasket orientation Figure 2 SunLite LTC Lamp Exploded View REPAIR PARTS LIST SUNLITE LTC LAMPS Key 05603 Series 05605 Series 05607 Series No Part Description Qty 12V 75W 120V 100W 120V 250W 1 Leader Screw 1 2 Face Ring SS Assy Kit 1 05601 0001 05601 0001 05601 0001 3 Rubber Retainer for Leader Screw 1 05601 0005 05601 0005 05601 0005 4 Clear Lens Kit 1 34620 0002 34620 0002 34620 0002 5 Gasket Lens 1 05601 0014 05601 0014 05601 0014 6 Clamp Ring Assembly 1 05601 0006 05601 0006 05601 0006 7 Lamp Housing 1 t t t Lamp 100W 120V Halogen T 4 MC 1 79102900 Lamp 75W 12V Halogen MR 16 1 79112400 Lamp 250W 130V Halogen T 4 MC 1 79113800 Replacement Screw Kit 1 05601 0101 05601 0101 05601 0101 t Not sold separately Not illustrated Included with Replacement Screw Kit SAVE THESE INSTRUCTIONS 2007 Pentair Water Pool and Spa Inc All rights reserved 1620 Hawkins Ave Sanford NC 27330 800 831 7133 or 919 56
3. 6 8000 10951 W Los Angeles Ave Moorpark CA 93021 800 831 7133 or 805 553 5000 This document is subject to change without notice STA RITE 715 Rev A 10 29 07
4. STA HITE SunLite LTC Small Underwater Pool Lights O W N ER S MAN UAL INSTALLATION OPERATION amp PARTS This manual should be furnished to the end user of this light its use will reduce service calls and chance of injury and will lengthen light life Pentair Water Pool and Spa Inc 1620 Hawkins Ave Sanford NC 27330 800 831 7133 or 919 566 8000 10951 West Los Angeles Ave Moorpark CA 93021 800 831 7133 or 805 553 5000 Visit us on the Internet at www pentairpool com or www staritepool com 715 Rev A 10 29 07 e 9 Attention Installer This manual contains important information about the installation operation and safe use of this product This information should be given to the owner and or operator of this equipment after installation A WARNING Before installing this product read and follow all warning notices and instructions which are included Failure to follow safety warnings and instructions can result in severe injury death or property damage Call 800 831 7133 for additional free copies of these instructions A DANGER Risk of Electrical Shock or Electrocution This product must be installed by a licensed or certified electrician or a qualified pool serviceman in accordance with the National Electrical Code and all applicable local codes and ordinances Improper installation will create an electrical hazard which could result in death or serious injury to pool users install
5. cal pool or spa wall not in floor Failure to install the fix ture properly could result in personal injury and or prop erty damage Do not push off from the poolside against the light Except when the fixture is installed in an area of the swimming pool that is not used for swimming and the lens is adequately guarded to keep any person from con tacting it the fixture shall be installed in or on a wall of the pool with the top of the lens opening not less than 18 below the normal level of the pool Locate junction box at least 8 above maximum water level and not less than 4 feet from the perimeter of the pool The junction box must be located e at least 4 from the perimeter of the pool unless sepa rated from the pool by a solid fence wall or other permanent structure e at least 8 above maximum water level e at least 4 above the deck or ground level Make sure that the installation is in compliance with local codes the NEC and the CEC as applicable See Figure 1 Page 5 The improper use of Ozone generators Chlorine genera tors Copper Silver lon generators or certain chemicals for water purification may cause damage to the fixture When such water purification methods are used be sure to monitor the water conditions Subjecting the fixture to extreme conditions or harsh environments may cause corrosion and premature failure of the fixture or its components A CAUTION Cutting hazard if l
6. en produced under UL s Listing and Follow Up Service for the associated usage location 2007 Pentair Water Pool and Spa Inc All rights reserved This document is subject to change without notice Trademarks and Disclaimers Sta Rite and SunLite are registered trademarks of Sta Rite Industries LLC Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products Pentair Water Pool and Spa Inc disclaims any proprietary interest in trademarks and trade names other than its own READ AND FOLLOW SAFETY INSTRUCTIONS This is the safety alert symbol When you see this symbol in this manual look for one of the follow ing signal words and be alert to the potential for personal injury Sa Warns about hazards that will cause serious personal injury death or major property damage if ignored A WARNING Warns about hazards that can cause serious personal injury death or major property damage if ignored A CAUTION warns about hazards that will or can cause minor personal injury or property damage if ignored The label NOTICE indicates special instructions which are important but not related to hazards Carefully read and follow all safety instructions in this manual and on equipment End user should save these instructions GENERAL SAFETY AWARNING Hazardous voltage Incorrectly installed or tested equipment may fail causin
7. ers or others due to electrical shock and may also cause damage to property Always disconnect the power to the pool light at the circuit breaker before servicing the light Failure to do so could result in death or serious injury to serviceman pool users or others due to electrical shock READ AND FOLLOW ALL INSTRUCTIONS IN THIS MANUAL A WARNING Important Safety Information for Pentair Niche and Light Installation e All Niche and Light installations must conform with all codes e Under no circumstances replace lights by splicing wire under water or behind niche A WARNING RISK OF ELECTRIC SHOCK AND INJURY USE ONLY THE INSTALLATION METHOD SPECIFIED BELOW Important Safety Information for Fountain Fixture Installations Location of Pentair Fountain Fixture Required Installation Method Luminaire Use P N 560000 P N 560001 P N 560002 P N 560003 Swimming Pool or Spa Wet Niche Swimming Pool Fixture Housing Forming Shell ONLY or Spa Luminaire Light DO NOT USE Fountain Fixture Stand Fountain Wet Niche Submersible Fixture Housing Forming Shell or Swimming Pool or Spa Fountain Fixture Stand Luminaire Light Note Wet niche luminaires complying with requirements for both uses may bear both the Listed Wet Niche Swimming Pool or Spa Luminaire UL Mark and the Listed Wet Niche Submersible Luminaire UL Mark A luminaire not bearing the corresponding UL Listing Mark is not considered by UL to have be
8. g severe injury or prop erty damage Read and follow instructions in owner s manual when installing and operating equipment Installation and maintenance of this circuit the light light niche and any other accessories attached to the circuit must be performed by a licensed electrician The complete electrical system must be installed tested and approved by a licensed electrician before it is placed in operation Failure to have this product installed by a licensed professional will void the product warranty AWARNING nisi of electrical shock Before removing fixture from pool wall ALWAYS TURN OFF THE POWER at the breaker All 12 Volt lamps require the installation of a 12 Volt transformer This light and its light niche must be installed in accor dance with Article 680 of the National Electrical Code NEC in the United States or Section 68 of the Canadian Electrical Code CEC as applicable and all local code requirements Install an approved Ground Fault Circuit Interrupter in the electrical circuit for this light All devices in the system must be directly grounded to a positive electrical ground All devices in the system must meet all applicable code requirements for bonding A WARNING Burn hazard Never operate this light fix ture for more than 10 seconds unless it is completely submerged in water This fixture requires total submer sion for cooling A WARNING Breakage hazard Install fixture in a verti
9. hten this screw securely 20 inch pounds torque to insure good electrical bonding Do not cut the grounding pin Do not use an extension cord Purchase a light with a longer cord Jm Be sure the power is off NOTICE The leader screw in the face ring may be recessed NOTE Do not try to loosen the strain relief cord nut on the back of the lamp housing the cord is not detachable from the lamp housing Attempting to loosen the strain 2 Place lamp housing on the deck above the niche Feed the cord through the back of the lamp housing and to the conduit box Make sure that there is enough cord to allow the fixture to be placed on the see General Safety Page 2 relief will damage the lamp housing assembly void the warranty and may cause an electrical shock hazard if the pool bonding is not connected and functioning correctly deck for re lamping Junction box 4 Ft Min To Fixture removed service for relamping Max water level A 4 n N eM 18 Min N To m Brass conduit To fixture Fixture i Sufficient cord to allow fixture to Pool wall be put on the deck for relamping Figure 1 Lamp Housing Installation Lamp Installation Instructions Re lamping See Figure 2 Page 7 for Key numbers 1 Be sure that the power is off Allow the lamp to cool before relamping 2 Remove the leader screw Key No 1 from the face ring and lift the lamp housing u
10. ight is improperly installed This light is for use only in commercial and residential swimming pools and spas It has not been designed tested or approved for use in wave pools lazy rivers or other waterpark features and should not be used in them Use in any application other than a swimming pool or spa may lead to damage to the light and cuts to swimmers and will void the warranty Sta Rite will not be responsible for any damages or injuries due to misapplication of this light SPECIFICATIONS SunLite LTC Small Underwater Pool Lights with Stainless Steel Face Ring Table Allowance of Watts Sq Foot Type of Pool of Pool Area Small Residential Pools Less than 800 sq ft 1 2 to 1 Large Public Pools 1 to 1 Diving Pools Less than 12 ft deep 1 to 2 Diving Pools 12 to 20 ft deep 2 to 3 Competition Pools 2 to 3 One 500 watt light at deep end of pool is recommended For competition pools i 2 Make sure that the start finish ends of lanes are well lighted Never install lights in end walls at end of swimming lanes However if short course racing is provided across width of a 50 meter course light fixtures may be installed between lanes under racing lines on a seperate switch Model No Cord Length in Feet m 12V 75 Watts 05603 2030 30 9 1 05603 2050 50 15 2 05603 2100 100 30 5 120V 100 Watts 05605 2030 30 9 1 05605 2050 50 15 2 05605 2100 100
11. p and out of the niche 3 Loosen the screw and nut on the clamp ring assembly Key No 5 until the nut is near the end of the screw Swing the screw and nut out of the forked slot of the clamp ring assembly and bend the clamp ring open to about 4 inches 4 To relamp 120V model remove the lamp by turning it counterclockwise and pulling it straight out Replace with an equivalent lamp For the 12V model remove the lamp by pulling it straight out while hold ing the spring clip back away from the socket Replace with an equivalent lamp 5 Using a clean soft lint free cloth carefully wipe all sealing surfaces on the lamp housing and lens NOTE Do not touch the lamp with your bare fingers If contact occurs clean the lamp glass with alcohol and a clean cloth To close the fixture make sure the clamp ring is open to about 4 inches and that the nut is at the end of the leader screw Lay the face ring face down on a flat surface Carefully align the clear lens Key No 4 and lens gasket Key No 5 over the flanged hole in the face ring key No 2 with the word top on the lens lined up with the leader screw on the face ring The silver tape should be on top and the arrow pointing toward the lamp Align the lamp housing over the lens gasket with the word top inline with the leader screw in the face ring Position one half of the clamp ring around the metal flanges of the face ring and lamp housing 1

Download Pdf Manuals

image

Related Search

Related Contents

ZyXEL NWD-370N User's Manual  Instituto Politécnico de V iseu - Repositório Científico do Instituto  Avid Xpress DV Effekte  Sony RDP-X200iPN  Caliber PS50I holder  RTX5000/RTX3500 取扱説明書  Bulletin d`information Hippoclub n°. 32  LC-Power 2000MB computer case  Tricity Bendix SE 211 User's Manual  ANGEL 7.3 Instructor Step by Step Guide  