NewAir ACP-1400E User's Manual

image

Contents

1. e A damaged supply cord should be replaced by the manufacturer its service agent or a qualified person in order to avoid a hazard e Any service other than regular cleaning or filter replacement should be performed by an authorized service representative Failure to do so could result in a loss of warranty Do not use your air conditioner under the following conditions If the power cable wires are frayed or cut Where small children may be left unattended On a slope or uneven surface Close to a naked flame This product is not made for DIY repair If there is a risk of liquid falling on the unit Inside unit exposed to the weather outdoors Near water If an extension lead may become overloaded Where the power cable may be damaged Where it may be damaged by chemicals Where there is a risk of interference by foreign objects PARTS 1 Front panel 2 Air outlet 3 Control panel 4 Rear panel 5 Right air inlet 6 Castor 7 Left air inlet 8 Cable storage 9 Hose connector 10 Exhaust hose 11 Drainage point with rubber water stopper 7 Left air inlet 8 Hose connector 9 Exha
2. with turbo speed the indicator light in red the Q indicator light in green Setting the temperature If you want to change the set temperature press the A or W button The 2 digit display will indicate the set temperature Note Reaching the set temperature depends on the room and outdoor climatic conditions Mode Pressing the Q button to switch the operating mode among cooling fan only dehumidification and heat Fan speed If you prefer a constant fan speed press the ac button successively e Fast for the turbo speed e Normal for the medium speed e Slow for the slow speed Timer For all of the following TIMER programming proceed firstly with these standard steps Press the button briefly the 2 digits on the control panel will show 00 Press the button again to program the timer for ON when the unit is OFF or program the timer for OFF when the unit is RUNNING The time will be increased by hour from 00 01 02 24 thence go back from 24 23 22 00 by each press of the button Press the button briefly to adjust the time as 00 to cancel the timer function Sleep mode The sleep mode function adjusts the set temperature of the unit to the thermal needs of the body falling asleep as follows e Default fan speed Low e Press the button to operate the sleep mode Press the button again in order to cancel the sleep mode The set temperature will incr
3. Portable Air Conditioner Owner s manual For ACP 1400E H Series THANK YOU Thank you for choosing this innovative air conditioner We suggest that you keep this manual in a safe place for future reference It describes the many benefits and advanced features this unique product has to offer Before you use your new air conditioner you should carefully read these instructions to maximize this product s performance SAFETY INSTRUCIONS IMPORTANT e The unit is designed for indoor operation The installation must be in accordance with regulations of the country where the unit is used If you are in any doubt about the electrical installation have it checked and if necessary modified by a qualified electrician The air conditioner is safe However as with other electrical appliances use it with care e Keep out of the reach of children e Do not clean the air conditioner by spraying it or immersing it in water e Do not insert any object into openings of the air conditioner e Disconnect it from all electricity before cleaning the unit or any of its components e Never connect the unit to an electrical outlet using an extension cord If an outlet is not available one should be installed by a licensed electrician Don t lift or move by pushing the air conditioner at the rear but always from the front side WARNING e Never operate this appliance if it has a damaged cord or plug Do not lead the cord over sharp edges
4. ease 2 F after 1 hour and a further 2 F after 2 hours No FAN ONLY DEHUMIDIFICATION mode under SLEEP mode operation Dehumidification If the unit will be used mainly as a dehumidifier just let the warm air return in the room Continuous drainage see separate chapter is then necessary and more efficient Only low fan speed under dehumidifying Heat optional function The unit features a heat pump that can heat a room on cooler days With the mode switch select heat with the temperature in 68 F as default You can set the desired temperature and the unit will heat until this temperature is reached Do not place the unit near anything that could catch fire or be scorched Do not obstruct the air outlet Ionizer amp UV Press 4s button to turn on the Ion amp UV function Press 4s button to turn off the Ion amp UV function Air flow The moment the air conditioner is connected to the electricity the louvers open then close and stay closed e When the ON button is pressed the louvers open to maximum AY e Press the A button the louvers will swing continuously up and down e When the ON button is pressed the louvers open to maximum AY By pressing the A button again the movement will stop and the louver remain in that position The direction of the air flow is then constant e When the OFF button is pressed the louvers close REMOTE CONTORL The unit responds to all signals that are sent by the rem
5. ff automatically and the water full indicator will be in red To empty the water container do the following e Switch off the unit and remove the plug from the wall socket Do not move the unit Doing this can result in water leakage damaging your floor or carpet e Place a water container on the floor underneath the permanent drainage point e Remove the rubber water stopper from the drain and let the water run out e Replace the rubber water stopper put the plug into the wall socket and Switch the unit on The red water full indicator should be off zn Scans HL u ER lt DO LEMON SAID OO D WI TA 6577 i i P E B a N N E NM i th LE E i E p NOTE When the air conditioner is in use under normal circumstances the condensed water will evaporate and then be discharged through the hot air outlet hose CONTINUOUS DRAINAGE e Switch off the unit and remove the plug from the mains e Remove the rubber water stopper e Connect a drain tube Y 16mm inner dimension onto the water outlet and extend with extra water tube if needed e Place the other end in a normal drain Make sure that the tube is free from twists and bends The tube must decline over its entire length CLEANING WARNING First of all switch off the unit and remove the plug from the wall Socket Clea
6. n the housing with a soft damp cloth Never use aggressive chemicals petrol detergents or other cleansing solutions Clean the screen filter regularly with a vacuum cleaner NOTE Never use the air conditioner without the screen filter STORAGE e Empty the internal water container e Clean the screen filter e Put the unit in Fan Only mode for a few hours to ensure that the inside becomes completely dry e Store the cable as shown OLD Protect the unit against dust and store in a dry place not accessible to children TROUBLE SHOOTING Never try to repair or dismantle the air condition yourself Incompetent repairs result in loss of warranty and can endanger the user and the property Problem The air Connect to a functioning outlet and switch T No power supply conditioner on does not l Timer function is active Deactivate TIMER function function Windows or doors open many Close doors and windows place an extra air The air people or a heat source in the u conditioner conditioner does room not seem to Dirty filter Clean or replace the filter perform Air inlet or air outlet blocked Remove the blockage Room temperature lower than the Change temperature selection selected value The unit is noisy Unit stands uneven Place on an even solid surface The compressor The overheat protection is Wait 3 minutes until the temperature has does not work probably acti
7. ose connector A in the hot air outlet 0 Connect the hose to hose connector A by turning it clockwise at least 5 turns Similarly connect the hose to hose connector B as far as possible COLD NEW Slide the hose connector B in the telescopic slide bar connector Place the telescopic slide bar in the open window or door and adjust the length to fill as much open space as possible COLD NEW Close the window or door as much as possible to prevent outside air entering the room Ensure that the hose connector B has a free flow outside IMPORTANT The flexible exhaust hose can be extended from 500 to 1500mm for mounting This length has been designed especially according to the specifications of the air conditioner Do not use an extension or exchange for a different hose as that may cause the unit to malfunction The exhaust air must flow freely any blockage can lead to overheating of the air conditioner Take care to prevent any sharp bow or bend in the exhaust OPERATION ON OFF Press to switch the unit on or to switch off a buzzer will beep and the 2 digits display will show 72 as default and the unit will run in cooling function
8. ote control There will be a beep sound from the unit after receiving the signal The operation of the unit by remote control is almost identical to the operation by the control panel The only exception is the temperature setting SFor setting the temperature The temperature will be increased from 64 F 65 F 92 F then go back from 92 F 89 F 64T by each press AIR FILTERS This air conditioner is equipped with two filter sets to clean the circulated room air A screen filter in the both sides of the unit to remove dust particles Clean the air filters The screen filters should be cleaned regularly by rinsing them under running water Note When the unit is running for 100 hours the 2 digits on the control panel will blink to remind you that the filter needs to be cleaned Press A and V buttons simultaneously to turn off the blinking of 2 digits Filter installation e Slide out the filter frame from both sides of the unit e Separate the filter fixer from the filter frame e Remove the carbon into the filter frame e Fix the filter by reassembling the fixer into the filter frame NOTE The screen filter must always be used 12 EMPTYING THE INTERNAL WATER CONTAINER Under high humidity conditions it may be necessary to empty the internal water container When the internal water container is full the beep will be alarmed in 15 times The unit will switch o
9. ust hose 10 Drainage point with rubber water stopper ACCESSORY a L Telescopic Slide Bar Connector NEW RRR VLR EIER RL SIRIOS Se Telescopic Slide Bar Carbon Filter Remote Control CONTROL PANEL l 2 3 4 9 6 YT 8 E Ed E ES Ed Ed ee A EN a O y v aoc uv amp lonizer Swing Timer SIe P Decrease Increase Fan Mode ON OFF Water full Timer Temperature LED Indicator Light 1 Ionizer amp UV indicator light in green 2 Swing indicator light in green 3 Timer indicator light in green 4 Sleep mode indicator light in green 5 Fan speeds a Fast indicator light in red b Normal indicator light in green c Slow indicator light in yellow 6 Mode a Cooling indicator light in green b Dehumidification indicator light in yellow c heat indicator light in red d Fan only no light 7 When the unit is working the indicator light will be in green 8 Water full indicator light in red INSTALLATION WARNING Before using the air conditioner it should be left in an upright position for at least 2 hours This unit can easily be moved from one room to another In doing so keep this in mind Ensure that the unit is positioned upright on a level surface and 50cm away from any obstacles Do not operate the unit inside the bathroom shower or in any other very humid environment Slide the h
10. ve decreased then turn on the unit again To correct problems that were not been described in this table and or if the recommended solutions fail to solve the problem contact an authorized service centre 15 16