1. the continental United States send defective unit carefully packaged postage prepaid along with description of trouble name return address and phone number to HAI Repair Department 4330 Michoud Blvd New Orleans LA 70129 HAI will pay return shipping charges via normal ground service Outside of the continental United States Contact an Authorized Distributor for repair replacement instructions c US LISTED
2. to 104 F Note It is normal for this switch to make a slight buzzing sound during operation It is also normal for the switch and wall plate to feel warm to the touch LIMITED WARRANTY HAI warrants this product against defects in material and workmanship under normal use and service for a period of two 2 years from the date of purchase During the warranty period HAI will repair or replace at its sole option if this product fails due to defect This warranty does not cover the cost of removal or reinstallation of any product This warranty does not cover failure caused by normal wear damage to the product while in your possession other than damage caused by defect or malfunction or by its improper installation including failure to follow the written installation and operation instructions alterations misuse or abuse The remedies provided for in this warranty are the sole and exclusive remedies thereof In no event shall HAI be liable for incidental expenses or consequential loss or damages For the complete HAI Warranty for USA policy see the HAI web site at www homeauto com Any implied warranties including warranties of merchantability and fitness for particular use or purpose are limited to a period of two 2 years from purchase date This warranty gives you specific legal rights and you may have other legal rights which vary from state to state Some limitations may not apply to you For warranty and repair service within
3. HAI HAI UPB 15A Relay Switch and Auxiliary Switch Installation and Operating Instructions LPEN For the following Models SU 40A00 1 HAI 15A Relay Switch referred to as HAI UPB Wall Switch in this document and 37A00 1 HAI Auxiliary Switch READ THESE INSTRUCTIONS BEFORE INSTALLING DEVICE This HAI UPB Wall Switch and Auxiliary Switch is intended for installation in accordance with the National Electrical Code and local codes and regulations It is recommended that a qualified electrician perform this installation Retain these instructions for reference This product is for indoor use only Connect only copper or copper clad wire to this device Important Notes Prior To Installation 1 All HAI UPB Wall Switches require a neutral white connection wire 2 Be sure that all power to the load has been disconnected by turning off the circuit breaker Installing an HAI UPB Wall Switch or Auxiliary Switch with power on may expose you to dangerous voltage and may damage the device HAI UPB Wall Switch Overview The HAI UPB Wall Switch Figure 1 allows for local control of loads by using the Decora style rocker switch It also incorporates the UPB two way powerline communication technology that gives it the ability to be remotely controlled by UPB compatible controllers The HAI UPB Wall Switch is also capable of transmitting UPB messages when the rocker switch is turned on or turned off The HAI 15A Re
4. HAI UPB Wall Switch using an HAI controller or a PC running the UPB UPStart configuration software it must be put into Setup Mode as follows Step Operation 1 Tap the rocker switch quickly 5 times 2 The HAI UPB Wall Switch will cycle the load one time and blink its LED blue to indicate that it is in Setup Mode Note the switch will automatically exit Setup mode after 5 minutes Reset to Factory Default Settings To reset the HAI UPB Wall Switch to factory default settings Step Operation 1 On the HAI UPB Wall Switch that you want to reset to factory default tap the rocker switch quickly 5 times The HAI UPB Wall Switch will cycle the load one time and blink its LED blue to indicate that it is ready to be reset Tap the rocker switch quickly 10 times to reset to factory default setting The HAI UPB Wall Switch will cycle the load one time and blink its LED red to indicate that it has been reset MN BY WwW hd Tap the rocker switch once more to stop the LED from blinking SPECIFICATIONS Model Number 40A00 1 Incandescent Loads Inductive Loads and Florescent Loads Yes Motor Operated Appliances Yes Current Maximum 15A Connections 18 GA LED Indicator Yes Dimensions 4 1 x 1 75 x 1 45 Weight 0 25 Ib Mounting Standard J Box Input Power 120 12 VAC Input Frequency 60 3 Hz Operating Temperature 40 F
5. OR CONNECT BLUE FOR BLUE INDICATOR GRAY FOR RED INDICATOR OR BOTH FOR MAGENTA INDICATOR BLUE AND OR GRAY WIRE MAY BE CONNECTED TO NEUTRAL OR EARTH GROUND NEUTRAL IS RECOMMENDED Figure 4 Wiring Diagram HAI 15A RELAY SWITCH OPERATION The HAI 15A Relay Switch has configurable items that can be set using the UPB UPStart configuration software The following describes the operation of the HAI 15A Relay Switch in its factory default configuration Local Rocker Switch Operation The HAI 15A Relay Switch has a Decora style rocker switch that can be used to control the load as follows Rocker Event Top Rocker Bottom Rocker Single Tap Load turns on Load turns off Table 1 HAI UPB 15A Relay Switch Local Operation LED Indicator The HAI UPB Wall Switch comes equipped with a multi color LED indicator that is normally lit to blue when the load is off The LED is off when the load is on If used the LED in the HAI Auxiliary Switch is always lit HAI AUXILIARY SWITCH OPERATION The HAI UPB Wall Switch can be connected to one or more HAI Auxiliary Switches producing multi way circuits Each HAI Auxiliary Switch has a Decora style rocker switch that controls the load in the exact same manner as the Decora style rocker switch on the connected HAI UPB Wall Switch as previously described When connected the LED remains continually on at all times while power is applied Setup Mode To configure the
6. gently depress the upper and lower latch on one side while lifting NE BK up on the plate Once the latches are released on one side remove the switch me plate from the other side 2 Align the latches of the new switch plate to the openings on the mounting plate y and gently snap into place Figure 3 Changing Switch Color INSTALLATION INSTRUCTIONS The HAI UPB Wall Switch is wired directly to the load and can be controlled by adding one or more optional HAI Auxiliary Switches producing multi way circuits Multi way circuits make it possible for a group of switches to control the same load This section will illustrate how to make the connections Notes 1 Refer to Figures 1 and Figure 2 to determine the wire colors for each connection 2 All HAI UPB Wall Switches require a neutral white connection 3 The Line black wire must be accessible for the installation of all HAI Auxiliary Switches This wire may be connected to either phase of the 120 240V supply The blue and or gray wire on the HAI Auxiliary Switch can be connected to either earth ground or neutral The blue and or gray wire is only used to light the LED on the switch This LED only indicates that power is applied and serves as a night light Connect the blue wire only to light the LED blue Connect the gray wire only to light the LED red Connect both the blue wire and the gray wire to light the LED magenta Installation Procedure 1 Be sure that all power to the l
7. lay Switch is used to control loads such as receptacles motor operated appliances i e fans and fluorescent lighting fixtures LED INDICATOR a TOP BLACK LINE ON WHITE NEUTRAL RED LOAD YELLOW BOTTOM on CONTROL OFF GREEN Figure 1 HAI UPB Wall Switch GROUND 40100 1 RevB HAI Auxiliary Switch Overview The 37A00 1 HAI Auxiliary Switch Figure 2 is an optional companion device used with the HAI UPB Wall Switch for multi way circuits The HAI Auxiliary Switch has a Decora style rocker switch that controls the load in the exact same manner as the Decora style rocker switch on the HAI UPB Wall Switch LED INDICATOR a TOP BLACK LINE ON GRAY NEUTRAL FOR RED INDICATOR BLUE NEUTRAL FOR BLUE INDICATOR BOTTOM YELLOW CONTROL OFF Figure 2 HAI Auxiliary Switch Changing Switch Color The color of the HAI UPB Wall Switch and Auxiliary Switch may be changed to complement the interior d cor The HAI UPB Wall Switch and Auxiliary Switch RAN A AG is supplied with a white switch plate Additional colors are available contact your pe J J i HAI distributor for more information When changing the switch plate make sure yye that the switch is disconnected from all power and proceed as follows ee 1 The switch plate attaches to the HAI UPB Wall Switch and Auxiliary Switch ON ii with two latches on the right and two on the left Using a small bladed we ao ae A screwdriver
8. oad has been disconnected by turning off the circuit breaker 2 If applicable remove the faceplate from the existing wall switch remove the existing wall switch from the wall box and disconnect the wires from the existing wall switch Identify the Line Neutral Load and Traveler if applicable wires 3 Remove of insulation from each of the wires on the HAI UPB Wall Switch Install the HAI UPB Wall Switch by connecting wires per wiring configuration shown in Figure 5 4 Install any optional HAI Auxiliary Switch per wiring configuration shown in Figure 5 5 After all connections have been made be certain that all wire connectors are firmly attached and there is no exposed copper 6 Gently place the wires and HAI UPB Wall Switch into the wall box with the LED at the top of device Using the supplied screws attach the HAI UPB Wall Switch to the wall box 7 Before installing the faceplate restore power to the circuit 8 After testing the HAI UPB Wall Switch and Auxiliary Switch for proper local operation Table 1 install a Decora style faceplate over each switch LINE e o 37A00 OPTIONAL 37A00 OPTIONAL 40A00 AUXILIARY SWITCH AUXILIARY SWITCH HAI Relay Switch 2 2 BLACK BLACK BLACK LOAD YELLOW YELLOW YELLOW Line 120VAC 60Hz WHITE RED BLUE AND OR GRAY BLUE AND OR GRAY GREEN NEUTRAL e e e e CONNECTING THE BLUE AND OR GRAY WIRE TO NEUTRAL SETS THE COLOR OF THE LED INDICAT