1. SITD RYER ON FLEXIBLE EXHAUS T DO NOT USE EXCESSIVE EXHAUST LENGTH 9 ALCOVE OR CLOSET INSTALLATION e If your dryer is approved for installation in an alcove or closet it will be stated on a label on the dryer back e The dryer MUST be vented to the outdoors See the EXHAUST INFORMATION section e Minimum clearance between dryer cabinet and adjacent walls or other surfaces is 0 in either side 3 in front and rear e Minimum vertical space from floor to overhead cabinets ceiling etc is 52 in e Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq in of open area equally distributed If the closet contains both a washer and a dryer doors must contain a minimum of 120 sq in of open area equally distributed e The closet should be vented to the outdoors to prevent gas pocketing in case of a gas leak in the supply line e No other fuel burning appliance shall be installed in the same closet with the dryer 10 gaTHROOM OR BEDROOM INSTALLATION e The dryer MUST be vented to the outdoors See EXHAUST INFORMATION section 6 e The installation must conform with local codes or in the absence of local codes with the NATIONAL FUEL GAS CODE ANSI 2223 11 MoBILE OR MANUFACTURED HOME INSTALLATION e Installation must conform to the MANUFACTURED HOME CONSTRUCTION amp SAFETY STANDARD TITLE 24 PART 32 80 or wh
2. K RER GEG SASK SS Cs SS OPEN GAS VALVE Check all connections for leaks with soapy solution or equivalent Apply soap solution Leak test solution must not contain ammo nia which could cause damage to the brass fittings If leaks are found close valve retighten the joint and repeat the soap test Installation Instructions ELECTRICAL CONNECTION INFORMATION A WARNING To REDUCE THE RISK OF FIRE ELECTRICAL SHOCK AND PERSONAL INJURY e DO NOT USE AN EXTENSION CORD OR AN ADAPTER PLUG WITH THIS APPLIANCE Dryer must be electrically grounded in accordance with local codes and ordinances or in the absence of local codes in accordance with the NATIONAL ELECTRICAL CODE ANSI NFPA NO 70 ELECTRICAL REQUIREMENTS This appliance must be supplied with 120V 60Hz and connected to a properly grounded branch circuit protected by a 15 or 20 amp circuit breaker or time delay fuse If electrical supply provided does not meet the above specifications it is recommended that a licensed electrician install an approved outlet A WARNING THIS DRYER Is EQUIPPED A THREE PRONG GROUNDING PLUG FOR YOUR PROTECTION AGAINST SHOCK HAZARD AND SHOULD BE PLUGGED DIRECTLY INTO A PROPERLY GROUNDED THREE PRONG RECEPTACLE DO NOT CUT OR REMOVE THE GROUNDING PRONG FROM THIS PLUG IF LOCAL CODES PERMIT AN EXTERNAL GROUND WIRE NOT PROVIDED WHICH MEETS LOCAL CODES MAY BE ADDED BY ATTACHING TO THE GREEN GROU
3. IF SPACE IS LIMITED USE THE INSTRUCTIONS IN SECTION 9 TO EXHAUST DIRECTLY FROM THE SIDES OR BOTTOM OF THE CABINET STANDARD REAR EXHAUST Vented at floor level FOR STRAIGHT LINE INSTALLATION CONNECT THE DRYER EXHAUST TO THE EXTERNAL EXHAUST HOOD USING DUCT TAPE OR CLAMP CSA AGA APPROVED NEW FLEXIBLE GAS LINE CONNECTOR EXTERNAL 4 LEVELING LEGS OPENING l STAND THE DRYER UPRIGHT NEAR THE FINAL LOCATION AND ADJUST THE 4 LEVELING LEGS TO MATCH THE HEIGHT OF YOUR WASHER 2 ANTI TIP LEGS ADJUST THE 2 ANTI TIP LEGS TO CONTACT DUCT TAPE OR THE FLOOR DUCT CLAMP 4 METAL DUCT CUT TO PROPER LENGTH DUCT TAPE OR DUCT CLAMP SZ NOTE WE STRONGLY RECOMMEND SOLID METAL EXHAUST DUCTING HOWEVER IF FLEXIBLE DUCTING IS USED IT MUST BE UL LISTED METAL NOT PLASTIC Installation Instructions CONNECTING THE DRYER TO HOUSE VENT RIGID METAL TRANSITION DUCT e For best drying performance a rigid metal transition duct is recommended e Rigid metal transitions ducts reduce the risk of crushing and kinking UL LISTED FLEXIBLE METAL SEMI RIGID TRANSITION DUCT e f rigid metal duct cannot be used then UL listed flexible metal semi rigid ducting can be used Kit WX08X1007 7 e Never install flexible metal duct in walls ceilings floors or other enclosed spaces e Total length of flexible metal duct should not exceed 8 feet 2 4m e For many applications installing elbows at both the dryer and the wall is highl
4. Connections and Venting Step 11 Place the Owners Manual and the Installation Instructions in a Location Where They Will Be Noticed By the Owner For Alcove or Closet Installation see section 9 For Bathroom or Bedroom Installation see section 10 For Mobile or Manufactured Home see section 11 234D1113P002 31 16225 1 07 08 10 GE Installation Instructions Minimum Clearance Other Than Alcove or Closet Installation Minimum clearance to combustible surfaces and for air opening are 0 in clearance both sides and 1 in rear Consideration must be given to provide adequate clearance for installation and service PREPARING FOR INSTALLATION GAS REQUIREMENTS OF NEW DRYER TIP Install your dryer before installing your washer A WARNING sw allow better access when installing dryer e Installation must conform to local codes and ordinances or in their absence the NATIONAL FUEL DISCONNECTING GAS Y GAS CODE ANSI Z223 TURN GAS e This gas dryer is equipped with a Valve amp Burner SHUT OFF VALVE E cae Assembly for use only with natural gas Using FLEXIBLE GAS CONNECTOR AND ae ae w OLD TRANSITION DUCTING conversion kit WE25X0217 your local service OS MATERIAL REPLACE WITH NEW organization can convert this dryer for use with ER ta ta propane LP gas ALL CONVERSIONS MUST BE MADE BY APPROVED TRANSITION DUCT PROPERLY TRAINED AND QUALIFIED PERSONNEL AND IN ACCORDANCE WITH LOCAL CODES AND ORDINANCE A WARNING never REUSE OLD REQUIREME
5. FROM THE DRYER with the dryer LEGS BE SURE TO eUse pipe thread sealer compound or Teflon tape appropri REMOVE ALL OF THE ate for natural or LP gas D aa Ane e You must use with this dryer a flexible metal connector listed connector ANSI 221 24 CSA 6 10 The length of the connect shall not exceed 3 ft e Connect flexible metal connector to dryer and gas supply e Open shut off valve Installation Instructions RECONNECTING GAS Listed connector ANSI Z21 24 CSA 6 10 OD yr GA FLARE NPT Nag ir OIA SA _ ADAPTER ge S Ty 7 ATA gt ES 1 8 NPTPIPE Conr WK PLUGFOR NEW METAL a CHECKING GAS FLEXIBLE GAS CE INLET PRESSURE LINE CONNECTOR sone Sor SHUT OFF 3 8 NPT Se A ELBOW lt A PIPE SIZE ITEMS NOT SUPPLIED 9 AT LEAST 1 2 Note The connector and fittings are designed for use only on the original installation and are not to be reused for another appliance or at another location Keep flare end of adaptor free of grease oil and thread sealant Caution Use adapters as shown Connector nuts must not be connected directly to pipe threads APPLY PIPE COMPOUND TO THE ADAPTER AND DRYER GAS INLET TIGHTEN THE FLEXIBLE GAS LINE USING TWO ADJUSTABLE WRENCHES D lt S SS APPLY PIPE COMPOUND TO ALL MALE THREADS TIGHTEN ALL CONNECTIONS USING TWO ADJUSTABLE WRENCHES DO NOT OVERTORQUE GAS CONNECTIONS OKA N ore te
6. e Save these instructions Installers Be sure to leave these instructions with the customer In the state of Massachusetts installation must be performed by a qualifiedor licensed contractor plumber or gasfitter qualified or licensed by the state 5 MATERIALS YOU WILL NEED 4 DIA METAL DUCT RECOMMENDED Ww 4 DIA FLEXIBLE METAL SEMI RIGID a UL LISTED TRANSITION DUCT U IF NEEDED KIT WX08X10077 ii 2 ELBOWS 4 DUCT CLAMPS 8 PIPE WRENCH LEVEL OR 4 SPRING CLAMPS SLIP JOINT PLIERS FLAT BLADE SCREWDRIVER Qe a amp P PIP 4 DIAMMETALELBOW EXHAUSTHOOD COMPOUND SOAP SOLUTION a FOR LEAK DETECTION COA SAFETY GLASSES 4 DIA FLEXIBLE METAL D UL LISTED TRANSITION DUCT IF NEEDED FLEXIBLE GAS LINE CONNECTOR Step 1 Verify Your Gas Installation see section 2 Step 2 Prepare the Area and Exhaust for Installation of New Dryer see section 1 Step 3 Check and Insure the Existing External Exhaust is Clean see section 1 and Meets Attached Installation Specifications see section 6 Step 4 Remove the Foam Shipping Pads see section 1 Step 5 Move the Dryer to the Desired Location Step 6 Level Your Dryer see section 8 Step 7 Connect the Gas Supply see section 3 and check for leaks see section 4 Step 8 Connect the External Exhaust see section 7 Step 9 Connect the Power Supply see section 5 Step 10 Check the Operation of the Power Supply Gas
7. metal or UL listed flexible metal RECOMMENDED semi rigid or foil type duct to connect the dryer CONFIGURATION to the home exhaust duct It must be installed TO MINIMIZE in accordance with the instructions found in EXHAUST Connecting The Dryer To House Vent on page 6 of BLOCKAGE this manual eDo not terminate exhaust in a chimney a wall a ceiling gas vent crawl space attic under an ELBOW HIGHLY enclosed floor or in any other concealed space of RECOMMENDED a building The accumulated lint could create a fire hazard e Never terminate the exhaust into a common duct with a kitchen exhaust system A combination of NOTE ELBOWS WILL PREVENT DUCT grease and lint creates a potential fire hazard KINKING AND COLLAPSING e Do not use duct longer than specified in the exhaust length table Longer ducts can accumulate lint creating a potential fire hazard LEVELING DRYER e Never install a screen in or over the exhaust duct This will cause lint to accumulate creating a potential fire LEVEL hazard FRONT TO BACK LEVEL e Do not assemble ductwork with any fasteners SIDE TO SIDE that extend into the duct These fasteners can accumulate lint creating a potential fire hazard e Do not obstruct incoming or exhausted air e Provide an access for inspection and cleaning of the exhaust system especially at turns and joints Exhaust system shall be inspected and cleaned at least once year THIS DRYER COMES READY FOR REAR EXHAUSTING
8. Installation Instructions Gas Dryer Questions on Installation Call 1 800 GECARES US or Visit our Web site at www GEAppliances com US BEFORE YOU BEGIN Read these instructions completely and carefully eIMPORTANT Save these instructions for local inspector s use eIMPORTANT Observe all governing codes and ordinances e Note to Installer Be sure to leave these instructions with the customer e Note to Customer Keep these instructions with your Use and Care Book for future reference e Before the old dryer is removed from service or discarded remove the dryer door e Inspect the dryer exhaust outlet and straighten the outlet walls if they are bent e Service information and the wiring diagram are located in the control console e Do not allow children on or in the appliance Close supervision of children is necessary when the appliance is used near children e Install the dryer where the temperature is above 50 F for satisfactory operation of the dryer control system TOOLS YOU WILL NEED WARNING risk oF FIRE e To reduce the risk of severe injury or death follow all installation instructions e Clothes dryer installation must be performed by a qualified installer e Install the clothes dryer according to these instructions and in accordance with local codes In the absence of local codes installation must comply with National Fuel Gas Code ANSIZ223 1 NFPA 54 or the Canadian Natural Gas and Prop
9. ND SCREW ON THE REAR OF THE DRYER AND TO A GROUNDED METAL COLD WATER PIPE OR OTHER ESTABLISHED GROUND 6 EXHAUST INFORMATION A WARNING IN CANADA AND IN THE UNITED STATES THE REQUIRED EXHAUST DUCT DIAMETER IS 4 IN 102mm DO NOT USE DUCT LONGER THAN SPECIFIED IN THE EXHAUST LENGTH TABLE Using exhaust longer than specified length will e Increase the drying times and the energy cost e Reduce the dryer life e Accumulate lint creating a potential fire hazard The correct exhaust installation is YOUR RESPONSIBILITY Problems due to incorrect installation are not covered by the warranty Remove and discard existing plastic or metal foil transition duct and replace with UL listed transition duct The MAXIMUM ALLOWABLE duct length and number of bends of the exhaust system depends upon the type of duct number of turns the type of exhaust hood wall cap and all conditions noted below The maximum duct length for rigid metal duct is shown in the table below EXHAUST LENGTH RECOMMENDED MAXIMUM LENGTH Exhaust Hood Types Use only fer short run installations Elbows ng Mota 90 Feet 60 Feet 60 Feet 45 Feet 45 Feet 35 Feet 35 Feet 25 Feet 25 Feet 15 Feet EXHAUST SYSTEM CHECK LIST HOOD OR WALL CAP e Terminate in a manner to prevent back drafts or entry of birds or other wildlife e Termination should present minimal resistance to the exhaust air flow and should require little or no m
10. NTS e The dryer must be disconnected from the gas supply FLEXIBLE CONNECTORS piping system during any pressure testing of that system at a test pressure in excess of 0 5 PSI 3 4 KPa e The dryer must be isolated from the gas supply piping system by closing the equipment shut off valve during any pressure testing of the gas supply piping of test REMOVING LINT FROM WALL pressure equal to or less than 0 5 PSI 3 4 KPa EXHAUST OPENING DRYER GAS SUPPLY CONNECTION J4 V AN The use of old flexible connectors can cause leaks and personal injury Always use new flexible connectors when installing gas appliances e Remove and discard existing plastic or metal foil transition duct and replace with UL listed transition TOL I duct NO00000 C 3 8 NPT MALE THREAD GAS SUPPLY INTERNAL DUCT DN NOTE Add to vertical dimension OPENING E CHECK THAT EXHAUST the distance between cabinet s HOOD DAMPER OPENS honam ito Ior AND CLOSES FREELY GAS SUPPLY e A 1 8 in National Pipe Taper thread plugged tapping accessible for test gauge connection must be installed immediately upstream of the gas supply connection to the dryer Contact your local gas utility should you have ee ee questions on the installation of the plugged tapping AND REMOVE THE FOAM Se a SHIPPING PADS BY e Supply line is to be 1 2 in rigid pipe and equipped with an PULLING AT THE SIDES accessible shut off within 6 ft of and in the same room AND BREAKING THEM l AWAY
11. aintenance to prevent clogging Never install a screen in or over the exhaust duct This could cause lint build up e Wall caps must be installed at least 12 in above ground level or any other obstruction with the opening pointed down SEPARATION OF TURNS For best performance separate all turns by at least 4 ft of straight duct including distance between last turn and exhaust ood TURNS OTHER THAN 90 e One turn of 45 or less may be ignored e Two 45 turns should be treated as one 90 turn e Each turn over 45 should be treated as one 90 turn SEALING OF JOINTS e All joints should be tight to avoid leaks The male end of each section of duct must point away from the dryer e Do not assemble the ductwork with fasteners that extend into the duct They will serve as a collection point for lint e Duct joints can be made air and moisture tight by wrapping the overlapped joints with duct tape e Horizontal runs should slope down toward the outdoors 12inch per foot INSULATION Duct work that runs through an unheated area or is near air conditioning should be insulated to reduce condensation and lint build up Installation Instructions EXHAUST CONNECTION STANDARD REAR EXHAUST Vented above floor level WARNING To REDUCE THE re RISK OF FIRE OR PERSONAL INJURY IA e This clothes dryer must be exhausted to the outdoors e Use only 4 rigid metal ducting for the home exhaust duct e Use only 4 rigid
12. and cause a safety hazard ADDING COVER PLATE TO REAR OF CABINET ROTATE DOOR 180 AND REINSTALL PLATE KIT WE1M454 Connect standard metal elbows and ducts to complete the exhaust system Cover back opening with a plate Kit WE1M454 available from your local service provider Place dryer in final location A WARNING NEVER LEAVE THE BACK OPENING WITHOUT THE PLATE Installation Instructions CONNECTING INLET HOSES CONNECTING INLET HOSES cont on some models PE E E To produce steam the dryer must connect to the cold 9 ok L i is ce e avis mg i water supply Since the washer must also connect to the en eienne h hniiuearen cold water a Y connector is inserted to allow both inlet faucet and hose couplings hoses to make that connection at the same time NOTE Use the new inlet hoses provided never use old hoses WATER SUPPLY REQUIREMENTS 1 Turn the cold water faucet off Remove the washer inlet ne anen an lend ace ae os a r tied ae hose from the washer fill valve connector cold u E on a NO Stelle ete 2 Ensure the rubber flat washer is in place and screw MUST be 3 4 in 1 9 cm garden hose type so inlet hoses the female coupling of the short hose onto the washer fill ee or seas vl eens MUST De peat os valve connector Tighten by hand until firmly seated oe me oe ie SUAE Che TOUM Ww Ole P Ce ponent 3 Attach the female end of the Y connector to the male ane a _ poe coupling of the short hose Ensur
13. ane Installation Code CSA B149 1 e California Safe Drinking Water and Toxic Enforcement Act This act requires the governor of California to publish a list of substances known to the state to cause cancer birth defects or other reproductive harm and requires businesses to warn customers of potential exposure to such substances Gas appliances can cause minor exposure to four of these substances namely benzene carbon monoxide formaldehyde and soot caused primarily by the incomplete combustion of natural gas or LP fuels Properly adjusted dryers will minimize incomplete combustion Exposure to these substances can be minimized further by properly venting the dryer to the outdoors e This dryer must be exhausted to the outdoors e Use only 4 rigid metal ducting for exhausting the clothes dryer to the outdoors e DO NOT install a clothes dryer with flexible plastic ducting materials If flexible metal semi rigid or foil type duct is installed it must be UL listed and installed in accordance with the instructions found in Connecting The Dryer To House Vent on page 6 of this manual Flexible venting materials are known to collapse be easily crushed and trap lint These conditions will obstruct dryer airflow and increase the risk of fire e Do not install or store this appliance in any location where it could be exposed to water and or weather e Dryers installed in residential garages must be elevated 18 46 cm above the floor
14. ar opening locate the tab in the middle of the appliance base Lift the tab to about 45 using a flat blade screwdriver ADDING NEW DUCT LEFT SIDE EXHAUST Reconnect the cut portion A of the duct to the blower housing Make sure that the shortened duct is aligned with the tab in the base Use the screw saved previously to secure the duct in place through the tab on the appliance base ADDING ELBOW AND DUCT FOR EXHAUST TO LEFT SIDE OF CABINET e Preassemble 4 elbow with 4 duct Wrap duct tape around joint e Insert duct assembly elbow first through the side opening and connect the elbow to the dryer internal duct CAUTION Be sure not to pull or damage the electrical wires inside the dryer when inserting the duct e Apply duct tape as shown on the joint between the dryer internal duct and the elbow CAUTION Internal duct joints must be secured with tape otherwise they may separate and cause a safety hazard TAPE Installation Instructions ADDING ELBOW FOR EXHAUST CHANGING DIRECTION OF THROUGH BOTTOM OF CABINET DOOR OPENING e Insert the elbow through the rear opening and connect it to the dryer internal duct e Apply duct tape on the joint between the dryer internal duct and elbow as shown on page 7 REMOVE 4 HOLE PLUGS AND REMOVE 4 PLACE THEM IN THE HOLES HINGE SCREWS ON THE OPPOSITE SIDE CAUTION Internal duct joints must be secured with tape otherwise they may separate
15. e the rubber flat washer NOTE A water softener is recommended to reduce is in place Tighten by hand until firmly seated buildup of scale inside the steam generator if the home water supply is very hard 15 SERVICING A WARNING LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS WIRING ERRORS 4 Insert the filter screen in the coupling of the washer s CAN CAUSE IMPROPER AND DANGEROUS inlet hose If a rubber flat washer OPERATION AFTER SERVICING is already in place remove it before installing the filter screen Attach this coupling to one male end of INSTALLATION the Y connector Tighten by hand until firmly seated 5 Ensure the rubber flat washer is in place and attach the dryer s long inlet hose to the other male end of the Y connector Tighten by hand until firmly seated 6 Ensure the rubber flat washer is in place and attach the other end of the dryer s long inlet hose to the fill valve connector at the bottom of the dryer back panel Tighten by hand until firmly seated For replacement parts and other information refer to Owner s Manual for servicing phone numbers TO REGISTER YOUR DRYER CALL TOLL FREE 7 Using pliers tighten all the couplings with 1 888 269 1192 an additional two thirds turn NOTE Do not overtighten Damage to the couplings may Prompt registration confirms your right to protection under the result terms of your warranty www GEAppliances c
16. en such standard is not applicable with AMERICAN NATIONAL STANDARD FOR MOBILE HOME NO 5018 e The dryer MUST be vented to the outdoors with the termination securely fastened to the mobile home structure See EXHAUST INFORMATION section 6 e The vent MUST NOT be terminated beneath a mobile or manufactured home e The vent duct material MUST BE METAL e KIT 14 D346 33 MUST be used to attach the dryer securely to the structure e The vent MUST NOT be connected to any other duct vent or chimney e Do not use sheet metal screws or other refastening devices which extend into the interior of the exhaust vent e Provide an opening with a free area of at least 25 sq in or introduction of outside air into the dryer room Installation Instructions 12 DRYER EXHAUST TO RIGHT LEFT OR BOTTOM CABINET A WARNING BEFORE PERFORMING THIS EXHAUST INSTALLATION BE SURE TO DISCONNECT THE DRYER FROM ITS ELECTRICAL SUPPLY PROTECT YOUR HANDS AND ARMS FROM SHARP EDGES WHEN WORKING INSIDE THE CABINET BE SURE TO WEAR GLOVES REMOVE SCREW DESIRED KNOCKOUT ONE ONLY Detach and remove the bottom right or left side knockout as desired Remove the screw inside the dryer exhaust duct and save Pull the duct out of the dryer Note Only 4 round rigid metal ducting allowed inside dryer FIXING HOLE ar P p Q Cut the duct as shown and keep portion A TAB LOCATION BEND TAB UP 45 Through the re
17. om 5 Lin hi For Questions on Installation Call 1 800 626 2000 US or 1 800 561 3344 Canada
18. y recommended see illustrations below Elbows allow the dryer to sit close to the wall without kinking and or crushing the transition duct maximizing drying performance e Avoid resting the duct on sharp objects UL LISTED FLEXIBLE METAL FOIL TYPE TRANSITION DUCT e In special installations it may be necessary to connect the dryer to the house vent using a flexible metal foiltype duct A UL listed flexible metal foil type duct may be used ONLY in installations where rigid metal or flexible metal semi rigid ducting cannot be used AND where a 4 diameter can be maintained throughout the entire length of the transition duct e In Canada and the United States only the flexible metall foil type ducts that comply with the Outline for Clothes Dryer Transition Duct Subject 2158A shall be used e Never install flexible metal duct in walls ceilings floors or other enclosed spaces e Total length of flexible metal duct should not exceed 8 feet 2 4m e Avoid resting the duct on sharp objects e For best drying performance 1 Slide one end of the duct over the clothes dryer outlet pipe 2 Secure the duct with a clamp 3 With the dryer in its permanent position extend the duct to its full length Allow 2 of duct to overlap the exhaust pipe Cut off and remove excess duct Keep the duct as straight as possible for maximum airflow 4 Secure the duct to the exhaust pipe with the other clamp