1. dryness level setting 6 47 39 33 28 if you prefer the air to be less dry this will reduce the amount of time that the dehumidifier runs Note This table is for reference only The dryness level settings can be approximated to relative humidity RH using Table 1 Energy Savings Tip 1 To reduce dehumidifier run time when using the Model 76 as an external control adjust the setting to be as high as is comfortable and when using the Model 76 as a remote control adjust the setting to be as low as is required for the space If it feels clammy or smells damp change the setting to allow for drier conditions Energy Savings Tip 2 When using the Model 76 as an external control turn the dehumidifier control OFF when you open your windows just as you would with air conditioning Energy Savings Tip 3 When using the Model 76 as an external control and if vacating your home for an extended period in the summer set the RH at 59 and set your thermostat to as high as you are comfortable setting it in the cooling mode Consult with appropriate professionals regarding the highest temperature that is safe for your pets or possessions This will keep the humidity at a controlled level to help prevent mold while minimizing the amount of cooling energy used LCD DISPLAY FIGURE 2 External Control LCD Display Numbers show i current room humidity OR humidity setting ES IDA o0 SET is displayed Solid O
2. IEAM Model 76 Dehumidifier Control Model 76 Dehumidifier Control Owner s Manual Installed by Installer Phone Date Installed PLEASE LEAVE THIS MANUAL WITH THE HOMEOWNER Thank you for your purchase of the Aprilaire Model 76 Dehumidifier Control Your control allows you to set the relative humidity level for your home and provides control of the dehumidifier from a convenient living space location The Model 76 uses an onboard sensor to monitor the relative humidity in the space in which it is located and displays the measured relative humidity on the digital display The Model 76 can also act as a remote control for your Aprilaire Model 1710A 1750A or 1770A dehumidifier if it is located in an inconvenient or hard to access area For example when the dehumidifier is located in and dehumiditying a crawl space or a basement the Model 76 can be installed where you spend most of your time allowing you to make changes to the setting and to see what the humidity is in these areas without having to access the dehumidifier SETTING THE DESIRED HUMIDITY LEVEL The control will allow you to set the desired humidity level in your home and can be used to turn dehumidification On or Off EXTERNAL CONTROL Begin by pressing the ON button and ON will be displayed on the LCD Screen see LCD display in Figure 1 Use the arrow buttons to set the control at 59 when first installed Allow the dehumidifier to run for 24 hours before decidi
3. N E AL 0 SET k when Ad or Wis Control On SON fase pressed The value inking ON b lt n isplayed is th Blinking ON ON OFF K dee Dehumidifying J T a g OFF Control Off Blinking ON Control Limit Exceeded See Control Limits page 6 90 1636 FIGURE 3 Remote Control LCD Display Numbers show remote location humidity OR dryness level setting FP A QO Le is displayed Solid ON gp mit f SET 4 when or Wis Control On iat amp pressed The value Blinking ON ON OFF displayed is the Dehumidifying kana J U ak OFF Control Off 90 1636 TURNING CONTROL ON OFF e Pressing the ON button will turn on the control FIGURE 4 ON OFF Buttons e Pressing the OFF button will turn off the control e The control will continue to display the measured ON OFF humidity when OFF e The humidity or dryness level setting cannot be a changed when the control is OFF CHANGING THE HUMIDITY OR DRYNESS LEVEL SETTING e The first press of either the A amp or W button will display the humidity or dryness level setting on the LCD e Each subsequent push of the up or down buttons will change the setting by 1 or 1 dryness level e f a button is held down the setting will continually change by 1 or 1 dryness level every 1 2 second for as long as the button is pressed e The control will exit the setting screen 5 seconds after the last bu
4. are outside of these limits e Dew Point Lower Limit 40 F External Control e Temperature High Limit 99 F External Control 105 F Remote Control e Temperature Low Limit 50 F Remote Control EXTERNAL CONTROL SEQUENCE OF OPERATION e The dehumidifier will turn off if one of the control limits has been exceeded e f the control measures a dew point below 40 F OR a temperature above 99 F the control will deactivate the dehumidifier output if actively dehumidifying the dehumidifier will stop dehumidifying and ON and will blink on the LCD screen see Figure 2 e The control will resume normal operation when conditions fall back within the control limits REMOTE CONTROL SEQUENCE OF OPERATION e The dehumidifier will turn off if one of the control limits has been exceeded e f the dehumidifier measures a temperature below 50 F or above 105 F the dehumidifier will stop dehumiditying e The contro will resume normal operation when conditions in the remote space fall back within the dehumidifier control limits CLEANING THE CONTROL The surface of the Model 76 Dehumidifier Control can be cleaned with water or a non abrasive household cleaner including glass cleaner Do not spray any liquid directly onto the control Spray water or a cleaner onto a soft cloth and gently wipe the surface of the control LIMITED WARRANTY Your Research Products Corporation Aprilaire Dehumidifier Control is expressly warranted f
5. ng if you want to change the humidity setting A Raise the setting if you prefer the air to be less dry this will reduce the amount of time that the dehumidifier runs W Lower the setting if you prefer the air to be more dry this will increase the amount of time that the dehumidifier runs FIGURE 1 Control Display and User Buttons LCD Display rilaire e Mode Buttons Use AV Buttons Use to view and to turn control On Off set humidity or dryness level setting REMOTE CONTROL The materials in a home act like a sponge so the moisture in the materials of your home is at the same level as the air After drying the air the materials of the home will release moisture back into the air until they are again at the same level As a result it is not uncommon for the dehumidifier to operate for an extended period of time when first installed Begin py Dies ihg POE Hoan Or TABLE 1 RH 5 Based on Dryness will be displayed on the LCD Screen see E E cor lemoerauire LCD display in Figure 1 Use the arrow y p buttons to set the control to a 3 dryness Dryness Indoor Temperature F level when first installed Allow the Level 65 dehumidifier to run for 24 hours before Setting 70 75 80 sete i you want to change the dryness 1 84 71 60 A Increase the dryness level setting if you prefer the air to be more dry this will increase the amount of time that the dehumidifier runs WY Decrease the
6. or five 5 years from date of installation to be free from defects in materials or workmanship Research Products Corporation s exclusive obligation under this warranty shall be to supply without charge a replacement for any control which is found to be defective within such five 5 year period and which is returned not later than thirty 30 days after said five 5 year period by you to either your original supplier or to Research Products Corporation Madison Wisconsin 53701 together with the installation date of the control THIS WARRANTY SHALL NOT OBLIGATE RESEARCH PRODUCTS CORPORATION FOR ANY LABOR COSTS AND SHALL NOT APPLY TO DEFECTS IN WORKMANSHIP OR MATERIALS FURNISHED BY YOUR INSTALLER AS CONTRASTED TO DEFECTS IN THE CONTROL ITSELF IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE SHALL BE LIMITED IN DURATION TO THE AFORESAID FIVE YEAR PERIOD RESEARCH PRODUCTS CORPORATION S LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OTHER THAN DAMAGES FOR PERSONAL INJURIES RESULTING FROM ANY BREACH OF THE AFORESAID IMPLIED WARRANTIES OR THE ABOVE LIMITED WARRANTY IS EXPRESSLY EXCLUDED THIS LIMITED WARRANTY IS VOID IF DEFECTS S RESULT FROM FAILURE TO HAVE THIS UNIT INSTALLED BY A QUALIFIED HEATING AND AIR CONDITIONING CONTRACTOR IF THE LIMITED WARRANTY IS VOID DUE TO FAILURE TO USE A QUALIFIED CONTRACTOR ALL DISCLAIMERS OF IMPLIED WARRANTIES SHALL BE EFFECTIVE UPON INSTALLATION some states do not allow limitation
7. s on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so the above exclusion or limitations may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state WARRANTY REGISTRATION Visit us on line at www aprilaire com to register your Aprilaire product If you do not have on line access please mail a postcard with your name address phone number email address product purchased date of purchase and dealer name and address to Research Products Corporation PO BOX 1467 Madison WI 53701 Your Warranty Registration information will not be sold or shared outside of this company P O Box 1467 e Madison WI 53701 1467 Phone 800 334 6011 Fax 608 257 4357 www aprilaire com 61000912 2 12 Printed in U S A B2205739A 2012 Aprilaire A division of Research Products Corporation
8. tton press release FIGURE 5 UP DOWN Buttons FIGURE 6 Humidity Setting Screen 0a 2 FIGURE 7 Dryness Level Setting Screen va HOW DOES THE CONTROL WORK EXTERNAL CONTROL e When the measured humidity is greater than the setting the control will turn on the dehumidifier and ON will blink on the LCD display e When the measured humidity falls 3 below the setting the contro will turn off the dehumidifier and ON will stop blinking but remain displayed on the LCD REMOTE CONTROL e The control sends the dryness level to the dehumidifier e Once per Cycle Period set by your installer in the dehumidifier the dehumidifier will sample the air in the area served by the dehumidifier e f the dew point of the incoming air is above the dryness level the dehumidifier will turn on and ON will blink on the LCD display e When the dew point of the incoming air falls below the setting the dehumidifier will turn off and ON will stop blinking but remain displayed on the LCD CONTROL LIMITS The control limits are used to make sure the dehumidifier does not run when conditions are outside of the operating limits Dehumidifiers are not as effective when conditions are outside of the operating limits For example the dehumidifier will not remove much moisture when conditions are cool and dry Control limits allow the dehumidifier to work efficiently within the operating range and turn off when conditions

Download Pdf Manuals

image

Related Search

Related Contents

MSI Z97A GAMING 7 motherboard  小売事業者の重大リスク回避 のご提案  PPA Mk Ⅱ - AccA inc.  RNA Clean-Up and Concentration Micro    barnini tecnologie avanzate flusso continuo nitrox 36000  電子化ドキュメントの活用  Multimedia Interface Bedienungsanleitung  3CCD Color Video Camera  Twentieth Century French Literature between memory and forgetting  