Home
American Standard 2903.XXXW User's Manual
Contents
1. ATE 15 AMP MAXIMUM GFCI CIRCUIT ELECTRICAL INSTALLATION SEPARATE 15 AMP GFCI OUTLET WHIRLPOOL MOUNTED 120 VAC AIR SWITCH OR WALL TIMER PUMP MOTOR ELECTRICAL DIAGRAM READ AND FOLLOW ALL INSTRUCTIONS 752878 100 Rev E 3 WIRE SELECTION GUIDE Maximum distance from fusebox to motor The sizes shown on this chart are recommendations Motor for copper conductors Hi Performance only Always follow Rating 115V Power Line local and national 1 6 electrical codes DRAIN CONNECTION AND SYSTEM TEST Using recommended drain opening connect whirlpool drain to waste line Tighten all drain joints securely Check the pump couplings and make sure they are hand tight Clean the whirlpool and fill with water to a point 2 above the top of the highest jet Recheck the pump couplings and make certain that they are not leaking Although the pump couplings are factory tightened and inspected some loosening may have occurred during transit Make sure the whirlpool is connected to the electrical supply and turn the whirlpool on Check for leaks around all piping connections while the whirlpool is running POST INSTALLATION CLEAN UP Remove all construction debris from bath Tile grout can be removed with a wooden popsicle stick or tongue depressor Do not use wire brushes or any other metal implement on bath surface Post installation clean up generally can be completed using warm water and liquid dishwashing detergent St
2. ECESSARY TO INSTALLATION oS ACCOMMODATE WHIRLPOOL METHOD AS DESIRED TEMPLATE ON OFF SWITCH DURING PROVIDED INSTALLATION LEVELING SURFACE WATERPROOF SEALANT IT MAY BE NECESSARY TO NOTCH DECK SURFACE AS PUMP MAY PROJECT BEYOND RIM OF BATH BY 1 1 2 ACCESS PANEL UNLESS AN ACCESS OPENING OF AT LEAST 12 X 24 305 X 610 mm IS PROVIDED WARRANTY SERVICE WILL NOT BE PERFORMED 752878 100 Rev E 2 SPIC AND SPAN IS A REGISTERED TRADEMARK OF PROCTER amp GAMBLE ELECTRICAL INSTALLATION INSTRUCTIONS All wiring must be performed by a licensed electrician in accordance with the national electrical code and all other applicable codes WARNING When using electrical products basic precautions should always be observed including the following 1 DANGER RISK OF ELECTRIC SHOCK Connect only to a circuit protected by a ground fault circuit interrupter 2 Grounding is required The unit should be installed by a licensed electrician and grounded 3 Install to permit access for servicing 4 All building materials and wiring should be routed away from the pump body and heater if equipped The whirlpool should be installed on a 120 vac 15 amp dedicated circuit The circuit should be hard wired from the electrical power supply panel The circuit must be a three 3 wire circuit from the electrical supply panel A grounded neutral wire and a third wire earth ground are essential ADDING THE SAFE T HEATER REQUIRES A SEPAR
3. SAVONA OVAL 2903 XXXW SERIES 41cam Standard HIGH GLOSS ACRYLIC SHOWN LESS ALL FITTINGS WHIRLPOOL BATHING POOL INSTALLATION INSTRUCTIONS tas 1524mm 60 lt _ _ 241 mm 9 1 2 t SEE FTTG SPECS FOR DIMENSION 1 Q OF SUPPLIES al 305mm 12 X 229 mm 9 CUTOUT IN FLOOR FOR DRAIN AOUTLINE OF CUTOUT USE TEMPLATE PUMP MAY EXTEND BEYOND 1073mm RIM BY 1 1 2 42 1 4 537mm 21 1 8 l PROVIDE ACCESS y TO PUMP FOR 76mm ON OFF SERVICING ON ALL 3 SWITCH INSTALLATIONS OF DRAIN 7 OUTLET i a C L OF C L OF l SHOWER ARM valves 1 95mm C L OF 3 3 4 305mm 102mm SPOUT 12 ae ER 51mm 2 Al 1651 1981mm 65 78 OPTIONAL 540mm t INTEGRAL 21 1 4 FEET 489mm SUPPORT 5 19 174 ROUGH FLOOR 1 SAFE T HEATER 1 1 2 N P T M A THREADS 1 1 2 O D TAILPIECE REMOVABLE BLANK rem 1 3 8 98mm 3 7 8 THANK YOU for selecting an American Standard bath Your new bath is shipped to you after careful inspection The whirlpool version is completely assembled with pump motor and system piping All you need to finish the installation are your selected fittings and electrical connections for a whirlpool To insure maximum performance and pleasure from this product please follow the instructions and cautions List of Optional Components not includ
4. ed e Safe T Heater 9075 120 List of Required Components not included e Drain 1583 470 e Bath Filler see your American Standard Distributor List of Required Tools and Supplies GENERAL SPECIFICATIONS FOR 2903 WHIRLPOOL INSTALLED SIZE WEIGHT WEIGHT w WATER GAL TO OVERFLOW 60 x 42 1 4 x 21 1 4 In 1524 x 1073 x 540mm 107 Lbs 49 Kg 640 Lbs 291 Kg WHIRLPOOL MIN OPERATING VOL BATHING WELL AT SUMP BATHING WELL AT RIM 45 x 23 In 1143 x 584mm 53 x 32 In 1346 x 813mm WATER DEPTH TO OVERFLOW FLOOR LOADING PROJECTED AREA PTS 35 Lbs Sq Ft 166 Kgs Sq m 64 Gal 243 L 53 Gal 201 L 15 In 381mm 27 8 CUBE FT 45 4 WHIRLPOOL ELECTRICAL SPECIFICATIONS SYSTEM PUMP 1 6 HP 9 7 AMPS 120V GENERAL INSTALLATION INFORMATION Tools Supplies e Level e Nails e Tape Measure e Putty e Pipe Wrench e Caulking waterproof e Slip Joint Pliers e 1x30r2x2 e Screw Driver Stringers e Standard e Drop Cloth Woodworking Tools e 15 amp GFI e Personal Safety Outlet Equipment e Cement Plaster e Caulking Gun Grout Carefully uncrate and inspect your new bath for any shipping damage If such damage is found report it to your vendor immediately After inspection and during installation protect the bath from construction damage After installation and before enclosing with wallboard tile etc water test the unit and check for leaks If a w
5. hirlpool do not make modifications to the whirlpool system or remove pump from factory mounting This could adversely affect the safety and performance of the whirlpool and void the warranty Do not handle or move the whirlpool by the pump motor or piping system Fittings bath filler shower arm etc are not provided with the bath and must be ordered separately Framing and enclosing materials are provided by others FOR AFTER SALES SERVICE CALL 1 800 442 1902 WEEKDAYS 752878 100 Rev E American Standard Inc 2005 All product names listed herein are trademarks of American Standard Inc unless otherwise noted FRAMING AND INSTALLATION The variety of installations possible for this bath may require framing procedures other than those shown Locate studs as required Insure rough dimensions are proper plumb and square For whirlpools provision must be made in all installations for an access opening for servicing pump and controls The following procedure must be used for all installations stringer or pier height should be as indicated The sump of the bath is supported by integral feet and no additional sump support is required Once the bath is in place the feet should be shimmed accordingly so that the rim of the bath contacts the stringer or pier but supports no weight Any finish material such as tile or wall board must be self supporting if it contacts the rim of the bath SUGGESTED TYPICAL INSTALLATION IT MAY BE N
6. ubbing with a white automotive type polishing compound and waxing with a liquid wax e Do not wax areas where you walk or stand e Do not allow nail polish remover acetone dry cleaning fluid paint remover or other solvents to come into contact with the surface e Clean the surrounding surface immediately after using caustic drain cleaners e Burning cigarettes will damage the surface e Should damage to the fixture occur repairs can be made quickly and easily Your distributor or builder can provide details 752878 100 Rev E 4 SPIC AND SPAN IS A REGISTERED TRADEMARK OF PROCTER amp GAMBLE
7. ubborn dirt or stains may be removed using granular Spic and Span mixed with water Painter s naphtha can be used to remove excess adhesives and or wet oil base paint FEATURES of YOUR NEW AMERICAN STANDARD ACRYLIC BATHTUB Your new acrylic bathtub has been molded in the newest plumbing fixture material available today Acrylics are tough durable finishes that are simple and easy to care for The colors have been formulated to match other American Standard fixtures and enhance your choice of bathroom decorations The high gloss surface is resistant to impact and chemicals and will retain its lasting luster with proper care and maintenance AFTERCARE and CLEANING e Always fill the tub with temperate water Excessively hot water may cause surface damage e Remove bath mat after use and hang to dry Allowing bath mat to dry in the tub may cause surface damage e Clean after use with a mild liquid household detergent cleaner Do not use Lestoil Lysol Disinfectant spray or concentrate or Lysol Basin Tub and Tile Cleaner Windex Mr Clean Dow Disinfectant Bathroom Cleaner or cleaning products in aerosol cans HARSH CHEMICALS SHOULD NEVER BE USED ON ACRYLIC SURFACES e Do not use wire brushes knives or sharp objects to remove stains cigarette tar deposits or other surface blemishes e Abrasive cleaners or powders must not be used since they will dull the surface If the glossy surface looses its sheen dulled areas can be restored by r
Download Pdf Manuals
Related Search
Related Contents
Mode d`emploi AS 620KM OPERATOR`S MANUAL MANUEL de L`UTILISATEUR MANUAL del Troubleshooting your unit: ワークシート ワークシート Manuel Utilisateur SÉRIE AMICO A1824 - France Automatismes UBM – CURSO DE DIREITO LEGISLAÇÃO ADMINISTRATIVA José MOVIDYN® Servoumrichter Positioniersteuerung - SEW Copyright © All rights reserved.
Failed to retrieve file