Cisco 16GB PC3-17000
Contents
1. Cla S 7 CO GA ee 2 Modular storage subsystem connector Ca CMOS battery USB connector Trusted Platform Module TPM Cisco UCS USBFLSHB 16GB is recommended but if another USB drive will be used it must be no wider than 0 8 inches and no more than 1 345 inches long in order to provide needed clearances to install or remove the USB drive 4 DIMM slots 10 DIMM diagnostic LED button Front heat sink and CPU 1 Adapter slot 1 6 CPU heat sink install guide pins 12 Adapter slot 2 Cisco UCS B200 M4 Blade Server 39 SUPPLEMENTAL MATERIAL CPUs and DIMMs Physical Layout Memory is organized as shown in Figure 8 Figure 8 UCS B200 M4 Memory Organization mM N O 2 N N N 24 DIMMS 1536 GB maximum memory with 64 GB DIMMs 4 memory channels per CPU up to 3 DIMMs per channel Each CPU controls four memory channels A B C D with three slots 1 2 3 within each channel m CPU1 Channels A B C and D Slot 1 A1 B1 C1 and D1 blue DIMM slots Slot 2 A2 B2 C2 and D2 black DIMM slots Slot 3 A3 B3 C3 and D3 white DIMM slots m CPU2 Channels E F G and H Slot 1 E1 F1 G1 and H1 blue DIMM slots 40 Cisco UCS B200 M4 Blade Server SUPPLEMENTAL MATERIAL Slot 2 E2 F2 G2 and H2 black DIMM slots Slot 3 E3 F3 G3 and H3 white DIMM slots The DIMM and CPU physical layout is shown in Figure 7
2. http www cisco com en US products ps10312 serv_group_home html Cisco UCS B200 M4 Blade Server 37 CONFIGURING the SERVER ORDER OPTIONAL KVM LOCAL I O CABLE The KVM local I O cable ships with every UCS 5100 Series blade server chassis accessory kit The KVM local I O cable provides a connection into the server with a DB9 serial connector a VGA connector for a monitor and dual USB ports for a keyboard and mouse With this cable you can create a direct connection to the operating system and the BIOS running on the server The KVM local I O cable ordering information is listed in Table 21 Table 21 KVM Local I O Cable Product ID PID PID Description N20 BKVM KVM local IO cable for UCS servers console port Figure 6 KVM Local I O Cable 192621 EE Connector to server front panel VGA connector for a monitor DB 9 serial connector Two port USB connector for a mouse and keyboard NOTE The blade chassis ships with the KVM local I O cable Q 38 Cisco UCS B200 M4 Blade Server SUPPLEMENTAL MATERIAL SUPPLEMENTAL MATERIAL System Board A top view of the UCS B200 M4 system board is shown in Figure 7 Figure 7 UCS B200 M4 System Board a Salic ESIk F1 is F2 m 2 F3 amp z e TTT I H3 ik H2 M H1 iE HL
3. Windows Server 2012 Datacenter 2 CPU Unlimited VMs Windows Server 2012 Standard 2 CPU 2 VMs No Cisco SVC Windows Server 2012 Datacenter 2 CPU Unlim VM No Cisco SVC Windows Server 2012 R2 Standard 2 CPU 2 VMs Windows Server 2012 R2 Datacenter 2 CPU Unlimited VMs Windows Server 2012 R2 Standard 2 CPU 2 VMs No Cisco SVC Windows Server 2012 R2 Datacen 2 CPU Unlim VM No Cisco Svc SUSE Linux Enterprise Srvr 1 2 CPU 1 Phys SUSE Linux Enterprise Srvr 1 2 CPU 1 Phys SUSE Linux Enterprise Srvr 1 2 CPU 1 Phys SUSE Linux Enterprise Svr 1 2 CPU Unl Vrt SUSE Linux Enterprise Svr 1 2 CPU Unl Vrt SUSE Linux Enterprise Svr 1 2 CPU Unl Vrt 5yr Support Reqd SUSE Linux High Availability Ext 1 2 CPU 1yr Support Reqd SUSE Linux High Availability Ext 1 2 CPU 3yr Support Reqd SUSE Linux High Availability Ext 1 2 CPU 5yr Support Reqd SUSE Linux GEO Clustering for HA 1 2 CPU 1yr Support Reqd SUSE Linux GEO Clustering for HA 1 2 CPU 3yr Support Reqd SUSE Linux GEO Clustering for HA 1 2 CPU 5yr Support Reqd SLES for SAP Applications 1 2 CPU 1 Phys 1yr Support Reqd SLES for SAP Applications 1 2 CPU 1 Phys 3yr Support Reqd SLES for SAP Applications 1 2 CPU 1 Phys 5yr Support Reqd SLES for SAP Applications 1 2 CPU Unl Vrt 1yr Support Reqd gt 1yr Support Reqd gt 3yr Support Reqd gt 5yr Support Reqd gt 1yr Support Reqd 3yr Support Reqd v SLES for SAP Applications 1 2 CPU Unl Vrt 3yr Su
4. tag also allows you to add your own asset tracking label without interfering with the intended air flow Network link status LED Blade ejector handle e Blade health LED Drive bay 1 10 Reset button access Drive bay 2 u Beaconing LED and button Notes 1 For information about the KVM local I O cable that plugs into the console connector a cable is included with every Cisco UCS 5100 Series blade server chassis accessory kit see ORDER OPTIONAL KVM LOCAL I O CABLE on page 38 4 Cisco UCS B200 M4 Blade Server BASE SERVER STANDARD CAPABILITIES and FEATURES BASE SERVER STANDARD CAPABILITIES and FEATURES Table 1 lists the capabilities and features of the base server Details about how to configure the server for a particular feature or capability for example number of processors disk drives or amount of memory are provided in CONFIGURING the SERVER on page 7 NOTE NOTE The B200 M4 blade server requires UCS Manager UCSM to operate as O part of the UCS system m The B200 M4 with E5 2600 v3 CPUs requires UCSM 2 2 3a or later Table 1 Capabilities and Features Capability Feature Description Chassis CPU Chipset Memory I O The UCS B200 M4 Blade Server mounts in a Cisco UCS 5100 Series blade server chassis or UCS Mini blade server chassis One or two Intel E5 2600 v3 Series processor family CPUs Intel C610 chipset 24 total DIMM slots m Support for Advanced ECC m Support for registered
5. 0 ee ee te ee eee 38 SUPPLEMENTAL MATERIAL 000 cee eee eee eee OO SVSECO DOA gevacuses buss o eee ace ta eeeeereeees smeeee eee ae eee os Sess 39 CPUS ang DINS 25 4 ah oe oe Bae Bak Oo ee abe Se eee OEE EES BOOS ee 40 Physical Layout sses eseese Coe oo S Gee eG ee caw e ee ee eS ese oe ee es 40 DIMM Population Rules 2 ee ee ee te tee te ee eee eee 41 DIMM Population Order 2 ce ee ee te tt te tee eee eee 42 Recommended Memory Configuration 2 eee ee te te ene 43 Additional DIMM Populations 0 cc ec ee ee te ee eee tees 44 Upgrade and Servicing Related Parts 0 ce ecw ee te ee te ee eee 45 Drive and Blade Server Blanking Panels 2 eee eee ee eee eee eee 45 Adding an Additional CPU with CPU heat sink or Replacing CPUs 46 Motherboard Lithium Battery 0 eee ee te ee eee ee ew eee 46 Thermal Grease with syringe applicator for CPU to Heatsink Seal 46 Air Baffle Replacement Kit 0 ccc cw ee wwe te ee et eee eee et eee 46 CPU Heat Sink Cleaning Kit 2 te te ee te et ee et eee 47 Network Connectivity 0 0 ccc eee wt ee eee eee ee eee ee eee tt eet eee 48 VIC 1340 1240 Adapter 4 4644 6 64644064 0454066 Cbd eee ose OES OS OED wS 49 Mezzanine Adapters 0 cece wee eee ee eee ee eee eee ee eee tees 51 B200 M4 Configured with 1 CPU 2 te te eee 52 B200 M4 Configured with 2 CPUS 1 te tet tt
6. 2 1 3 as defined by the Trusted Computing Group TCG It is also SPl based oO Cisco UCS B200 M4 Blade Server 25 CONFIGURING the SERVER STEP 8 ORDER SECURE DIGITAL CARDS OPTIONAL Dual SDHC flash card sockets are provided on the front left side of the server O NOTE Dual card support mirroring is supported The SDHC card ordering information is listed in Table 11 Table 11 Supported Secure Digital Cards Product ID PID PID Description UCS SD 64G S 64 GB SD Card module for UCS Servers UCS SD 32G S 32 GB SD Card module for UCS Servers Supported Configurations 1 Select either one or two 64 GB SD cards or one or two 32 GB SD cards Do not mix 64 GB SD cards with 32 GB SD cards 26 Cisco UCS B200 M4 Blade Server CONFIGURING the SERVER STEP 9 ORDER INTERNAL USB 2 0 DRIVE OPTIONAL You may order one optional internal USB 2 0 drive The USB drive ordering information is listed in Table 12 Table 12 USB 2 0 Drive Product ID PID PID Description UCS USBFLSHB 16GB UCS Servers 16GB Flash USB Drive NOTE A clearance of 0 950 inches 24 1 mm is required for the USB device to be inserted and removed see the following figures A peephole is provided so you can see the connector for the USB drive see also the figures on the following page t 920 a CLERANCE FOR V USB TO SLIDE OUT Peephole See Figure 7 on page 39 for the location of the USB con
7. Cisco m Two SD card slots are available on the front left side of the server 32 GB or 64 GB SD cards are available from Cisco The Cisco Integrated Management Controller CIMC provides video using the Matrox G200e video graphics controller m Integrated 2D graphics core with hardware acceleration m DDR2 3 memory interface supports up to 512 MB of addressable memory 8 MB is allocated by default to video memory m Supports display resolutions up to 1920 x 1200 16bpp 60Hz m High speed integrated 24 bit RAMDAC m Single lane PCI Express host interface running at Gen 1 speed m Front panel e One console connector see ORDER OPTIONAL KVM LOCAL I O CABLE on page 38 Integrated in the Cisco UCS 5100 Series blade server chassis or UCS Mini blade server chassis Integrated in the Cisco UCS 5100 Series blade server chassis or UCS Mini blade server chassis The built in Cisco Integrated Management Controller CIMC GUI or CLI interface enables you to monitor the server inventory health and system event logs Cisco UCS B200 M4 Blade Server CONFIGURING the SERVER CONFIGURING the SERVER Follow these steps to configure the Cisco UCS B200 M4 Blade Server STEP 1 VERIFY SERVER SKU page 8 STEP 2 CHOOSE CPU S page 9 STEP 3 CHOOSE MEMORY page 11 STEP 4 CHOOSE RAID CONT ROLLER AND DISK DRIVE BAYS page 16 STEP 5 CHOOSE HARD DISK DRIVES or SOLID STATE DRIVES OPTIONAL page 18 STEP 6 CHOOSE ADAPTERS page 20 STEP 7
8. ORDER TRUSTED PLATFORM MODULE OPTIONAL page 25 STEP 8 ORDER SECURE DIGITAL CARDS OPTIONAL page 26 STEP 9 ORDER INTERNAL USB 2 0 DRIVE OPTIONAL page 27 STEP 10 CHOOSE OPERATING SYSTEM AND VALUE ADDED SOFTWARE page 29 STEP 11 CHOOSE OPERATING SYSTEM MEDIA KIT page 32 STEP 12 CHOOSE SERVICE and SUPPORT LEVEL page 33 Cisco UCS B200 M4 Blade Server 7 CONFIGURING the SERVER STEP 1 VERIFY SERVER SKU Verify the product ID PID of the server as shown in Table 2 Table 2 PID of the Base UCS B200 M4 Blade Server Product ID PID Description UCSB B200 M4 UCS B200 M4 Blade Server without CPU memory drive bays HDD VIC adapter or mezzanine adapters The base Cisco UCS B200 M4 blade server does not include the following components They must be selected during product ordering m CPUs Memory Cisco FlexStorage RAID controller with drive bays or blank for no local drives support Disk drives Cisco adapters such as the VIC 1340 VIC 1380 VIC 1240 VIC 1280 or Port Expander Cisco UCS Storage Accelerators such as the Fusion io adapter O NOTE Use the steps on the following pages to order servers with the Ne configurable components that you want configured in your servers 8 Cisco UCS B200 M4 Blade Server STEP 2 CHOOSE CPU S The standard CPU features are m Intel Xeon E5 2600 v3 series processor family CPUs m Intel C610 series chipset CONFIGURING the SERVER m Up to 18 cores per proces
9. Support Rqd VMW VS5 ENT 3A VMware vSphere 5 Enterprise for 1 CPU 3 Yr Support Rqd VMW VS5 ENT 4A VMware vSphere 5 Enterprise for 1 Processor 4 Year Support Rqd VMW VS5 ENT 5A VMware vSphere 5 Enterprise for 1 CPU 5 Yr Support Rqd VMW VS5 ENTP 1A VMware vSphere 5 Enterprise Plus for 1 Processor 1 Year Support Rqd VMW VS5 ENTP 2A VMware vSphere 5 Enterprise Plus for 1 CPU 2 Yr Support Rqd VMW VS5 ENTP 3A VMware vSphere 5 Enterprise Plus for 1 Processor 3 Year Support Rqd VMW VS5 ENTP 4A VMware vSphere 5 Enterprise Plus for 1 Processor 4 Year Support Rqd VMW VC5 STD 1A VMware vCenter 5 Server Standard 1 yr support required VMW VC5 STD 2A VMware vCenter 5 Server Standard 2 yr support required VMW VC5 STD 3A VMware vCenter 5 Server Standard 3 yr support required VMW VC5 STD 4A VMware vCenter 5 Server Standard 4 yr support required VMW VC5 STD 5A VMware vCenter 5 Server Standard 5 yr support required NOTE For additional information see OS hypervisor support matrix at the O following link SS http www cisco com en US products ps10477 prod_technical_reference_list html Cisco UCS B200 M4 Blade Server 31 CONFIGURING the SERVER STEP 11 CHOOSE OPERATING SYSTEM MEDIA KIT Choose the optional operating system media listed in Table 14 Table 14 OS Media Product ID PID PID Description RHEL 6 RHEL 6 Recovery Media Only Multilingual SLES 11 SLES 11 media only multilingual 32 Cisco UCS B200 M4 Blade Server CONF
10. and SSDs Product ID PID HDDs UCS HD12T10KS2 E A03 D600GA2 UCS HD450G15KS2 E UCS HDD300GI2F105 A03 D300GA2 18 PID Description 1 2 TB 6G SAS 10K RPM SFF HDD 600 GB 6Gb SAS 10K RPM SFF HDD 450 GB SAS 15K RPM SFF HDD 300 GB 6Gb SAS 15K RPM SFF HDD 300 GB 6Gb SAS 10K RPM SFF HDD Drive Type SAS SAS SAS SAS SAS Capacity 1 2 TB 600 GB 450 GB 300 GB 300 GB Cisco UCS B200 M4 Blade Server CONFIGURING the SERVER Table 7 Supported Hot Pluggable Sled Mounted HDDs and SSDs continued Product ID PID SSDs UCS SD161T12S2 EP UCS SD400G12S2 EP UCS SD800GOKS2 EP UCS SD400GOKS2 EP UCS SD200GOKS2 EP UCS SD960GOKS2 EV UCS SD480GOKS2 EV UCS SD240GOKS2 EV UCS SD120GOKS2 EV PID Description 1 6 TB 2 5 inch Enterprise Performance 12G SAS SSD 400 GB 2 5 inch Enterprise Performance 12G SAS SSD 800 GB 2 5 inch Enterprise Performance SAS SSD 400 GB 2 5 inch Enterprise Performance SAS SSD 200 GB 2 5 inch Enterprise Performance SAS SSD 900 GB 2 5 inch Enterprise Value 6G SATA SSD 480 GB 2 5 inch Enterprise Value 6G SATA SSD 240 GB 2 5 inch Enterprise Value 6G SATA SSD 120 GB 2 5 inch Enterprise Value 6G SATA SSD Supported Configurations 1 1 Drive System m Select one of the drives listed in Table 7 1 2 Drive System m Select two drives from Table 7 Caveats Drive Type SAS SAS SAS SAS SAS SATA SATA SATA SATA Capacity 1 6 TB 400 GB 800 GB 400 GB 200 GB 960 GB 480 G
11. eee 5 TECHNICAL SPECIFICATIONS 0 2c eee ee ee OL Dimensions and Weight 2 cece eee ee we ee eee ee eee eee ee eee ete eee 62 Power Specifications 04 4 tooe eo eS b44 4424S SS Ee wk EO ew ARE LED EET HS S 62 Cisco UCS B200 M4 Blade Server OVERVIEW OVERVIEW Delivering performance versatility and density without compromise the Cisco UCS B200 M4 Blade Server addresses the broadest set of workloads from IT and web infrastructure through distributed database The enterprise class Cisco UCS B200 M4 blade server extends the capabilities of Cisco s Unified Computing System portfolio in a half width blade form factor The Cisco UCS B200 M4 harnesses the power of the latest Intel Xeon E5 2600 v3 Series processor family CPUs with up to 1536 GB of RAM using 64 GB DIMMs two solid state drives SSDs or hard disk drives HDDs and up to 80 Gbps throughput connectivity Figure 1 Cisco UCS B200 M4 Blade Server Cisco UCS B200 M4 Blade Server DETAILED VIEWS DETAILED VIEWS Blade Server Front View Figure 2 is a detailed front view of the Cisco UCS B200 M4 Blade Server Figure 2 Blade Server Front View IGT sls eA MMM UCS 5200 m ETT Ts SISOS SSS elSlOl im Oe NN jaa a a a yan aan N20 BBLKD oog e CFS 353269 Asset pull tag Each server has a plastic tag that pulls out of the front panel The tag contains the server serial number as well as the product ID PID and version ID VID The
12. er Product ID PID Level GSP Site Description CON UCW7 B200M4 UCW7 Yes UC PLUS 24X7X40S UCS B200 M4 Blade Server CON UCW5 B200M4 UCW5 Yes UC PLUS 8X5XNBDOS UCS B200 M4 Blade Server Unified Computing Partner Support Service Cisco Partner Support Service PSS is a Cisco Collaborative Services service offering that is designed for partners to deliver their own branded support and managed services to enterprise customers Cisco PSS provides partners with access to Cisco s support infrastructure and assets to help them m Expand their service portfolios to support the most complex network environments m Lower delivery costs m Deliver services that increase customer loyalty Partner Unified Computing Support Options enable eligible Cisco partners to develop and consistently deliver high value technical support that capitalizes on Cisco intellectual assets This helps partners to realize higher margins and expand their practice PSS is available to all Cisco PSS partners but requires additional specializations and requirements For additional information see the following URL www cisco com go partnerucssupport The two Partner Unified Computing Support Options include m Partner Support Service for UCS m Partner Support Service for UCS Hardware Only Partner Support Service for UCS provides hardware and software support including triage support for third party software backed by Cisco technical resources and level three support 3
13. m All DIMMs must be DDR4 DIMMs m Do not mix DIMMs with different clock rates in a channel RDIMMs and LRDIMMs m There are blue black and white DIMM slots Populate blue slots first m When DIMMs ranks are mixed in the same channel always populate the highest rank DIMM in the blue DIMM slot and lower rank DIMM s in the black and white DIMM slots Many memory configurations are possible For best results follow Table 24 when populating 2133 MHz DIMMs for Intel Xeon E5 2600 v3 CPUs Table 24 Recommended Memory Configurations for Intel Xeon E5 2600 v3 CPUs with 2133 MHz DIMMs CPU 1 DIMMs CPU 2 DIMMs System Blue Slots Black Slots White Slots Blue Slots Black Slots White Slots DIMM Max Slot 1 Slot 2 Slot 3 Slot 1 Slot 2 Slot 3 Speed A1 B1 A2 B2 A3 B3 E1 F1 E2 F2 E3 F3 MHz C1 D1 C2 D2 C3 D3 G1 H1 G2 H2 G3 H3 i icin OE MI iad MG T a a a kad a 4x16 GB 4x16 GB 2133 i 4x16 GB 2x16 GB 4x16 GB 2x16 GB 2133 12 4x16 GB 4x8 GB 4x16 GB 4x8 GB 2133 16 256 GB 4x16 GB 4x16 GB E 4x16 GB 4x16 GB ma 2133 4x32 GB 4x32 GB 2133 4x16 GB 4x16 GB 4x16 GB 4x16 GB 4x16 GB 4x16 GB 1866 512 GB 4x32 GB 4x32 GB 4x32 GB 4x32 GB 2133 16 768 GB 4x32 GB 4x32 GB 4x32 GB 4x32 GB 4x32 GB 4x32 GB 1866 24 4x64 GB 4x64 GB 4x64 GB 4x64 GB 4x64 GB 4x64 GB 1600 Notes 1 Rows marked in yellow indicate best performance 2 Unbalanced configuration memory not populated equally across th
14. without a Cisco FlexStorage RAID controller with disk drive bays however be sure to select the Cisco FlexStorage blanking panels The ordering information is listed in Table 8 Table 6 Cisco UCS B Series M4 Blade Server RAID Controller and Drive Bay Options Product ID PID PID Description UCSB MRAID12G Cisco FlexStorage 12G SAS RAID controller with drive bays UCSB MRAID12G HE2 Cisco FlexStorage 12G SAS RAID controller with 2 GB flash backed write cache with drive bays UCSB LSTOR BK Cisco FlexStorage blanking panels w o controller w o drive bays Notes 1 Cisco FlexStorage 12G SAS RAID controller powered by the LSI SAS 3108 chip see http www si com products raid on chip pages Isi sas 3108 aspx with drive bays providing up to 12 Gbps SAS connectivity offering SAS SATA support RAID 0 and 1 and non RAID 2 The flash backed write cache provides RAID controller cache protection using NAND flash memory anda supercapacitor In the event of a power or server failure cached data is automatically transferred from the RAID controller DRAM write cache to flash Once power is restored the data in the NAND flash is copied back into the DRAM write cache until it can be flushed to the disk drives See Figure 4 on page 17 for a top view of the B200 M4 server with and without the Cisco FlexStorage SAS RAID controller and drive bays See Figure 5 on page 17 for a front view of these configurations When no drive bays are installed bl
15. 00 1 Because all DDR4 DIMMs supported on this server run at 2133 MHz the DIMMs will be clocked at the speed supported by the CPU Cisco UCS B200 M4 Blade Server CONFIGURING the SERVER 2 The E5 2609 v3 CPU does not support Intel Hyper Threading or Intel Turbo Boost technologies Supported Configurations 1 One CPU Configuration m Choose one CPU from any one of the rows of Table 3 on page 9 2 Two CPU Configuration m Choose two identical CPUs from any one of the rows of Table 3 on page 9 Caveats m if the mezzanine slot is either empty or contains a Port Expander Card for VIC only 1 CPU is required although you may install 2 CPUs m If the mezzanine slot contains anything but a Port Expander Card for VIC 2 CPUs are required to make the mezzanine slot operable m See Table 9 on page 23 for more details regarding how many CPUs are required for different I O or mezzanine adapter card configurations Also see B200 M4 Configured with 1 CPU on page 52 and B200 M4 Configured with 2 CPUs on page 57 10 Cisco UCS B200 M4 Blade Server CONFIGURING the SERVER STEP 3 CHOOSE MEMORY The standard memory features are m DIMMs Clock speed 2133 MHz Ranks per DIMM 1 2 or 4 Operational voltage 1 2 V Registered ECC DDR4 DIMMs RDIMMs or load reduced ECC DDR4 DIMMs LRDIMMs m Memory is organized with four memory channels per CPU with up to three DIMMs per channel DPC as shown in Figure 3 Figur
16. 1 Supported only through UCS Manager version 2 2 3a and later Cisco UCS B200 M4 Blade Server 23 CONFIGURING the SERVER To check that your operating system is compatible with the adapter you have selected please check the Hardware Compatibility List at this URL http www cisco com en US products ps10477 prod_technical_ reference _list html Caveats m You must have VIC 1340 or VIC 1240 adapter installed in order to have I O connectivity 24 Cisco UCS B200 M4 Blade Server CONFIGURING the SERVER STEP 7 ORDER TRUSTED PLATFORM MODULE OPTIONAL Trusted Platform Module TPM is a computer chip or microcontroller that can securely store artifacts used to authenticate the platform or server These artifacts can include passwords certificates or encryption keys A TPM can also be used to store platform measurements that help ensure that the platform remains trustworthy Authentication ensuring that the platform can prove that it is what it claims to be and attestation a process helping to prove that a platform is trustworthy and has not been breached are necessary steps to ensure safer computing in all environments See Figure 7 on page 39 for the mounting location of the TPM The TPM ordering information is listed in Table 10 Table 10 Trusted Platform Module Product ID PID PID Description UCSX TPM2 001 Trusted Platform Module 1 2 for UCS SPl based NOTE The module used in this server conforms to TPM v1
17. 4 Cisco UCS B200 M4 Blade Server CONFIGURING the SERVER See Table 17 Table 17 Partner Support Service for UCS Product ID PID FEA ee Description CON PSJ1 B200M4 PSJ1 No UCS SUPP PSS 8X5XNBD UCS B200 M4 Blade Server CON PSJ2 B200M4 PSJ2 No UCS SUPP PSS 8X5X4 UCS B200 M4 Blade Server CON PSJ3 B200M4 PSJ3 No UCS SUPP PSS 24X7X4 UCS B200 M4 Blade Server CON PSJ4 B200M4 PSJ4 No UCS SUPP PSS 24X7X2 UCS B200 M4 Blade Server Partner Support Service for UCS Hardware Only provides customers with replacement parts in as little as two hours See Table 18 Table 18 Partner Support Service for UCS Hardware Only Product ID PID eee ee Description CON PSW2 B200M4 PSW2 No UCS W PL PSS 8X5X4 UCS B200 M4 Blade Server CON PSW3 B200M4 PSW3 No UCS W PL PSS 24X7X4 UCS B200 M4 Blade Server CON PSW4 B200M4 PSW4 No UCS W PL PSS 24X7X2 UCS B200 M4 Blade Server Unified Computing Combined Support Service Combined Services makes it easier to purchase and manage required services under one contract SMARTnet services for UCS help increase the availability of your vital data center infrastructure and realize the most value from your unified computing investment The more benefits you realize from the Cisco Unified Computing System Cisco UCS the more important the technology becomes to your business These services allow you to m Optimize the uptime performance and efficiency of your UCS m Protect your vital business applications by
18. B 240 GB 120 GB m For RAID ed configurations if you select two drives they must be identical in type HDD or SSD and capacity m For non RAID ed configurations if you select two drives you can mix and match any combination of HDD and SSD regardless of capacity Cisco UCS B200 M4 Blade Server 19 CONFIGURING the SERVER STEP 6 CHOOSE ADAPTERS The adapter offerings are m Cisco Virtual Interface Cards VICs Cisco developed 1200 Series and 1300 Series Virtual Interface Cards VICs to provide flexibility to create multiple NIC and HBA devices The VICs also support adapter Fabric Extender and Virtual Machine Fabric Extender technologies The VIC features are listed here 1200 Series VICs enable advanced networking features including Netflow for network statistics and DPDK USNIC for low latency computing applications 1300 Series VICs include all of the 1200 Series features plus additional enhancements including network overlay offload support for NVGRE and VXLAN and RoCE services In addition 1300 Series VICs support PCle Gen 3 0 for greater bandwidth than 1200 Series VICs Two Converged Network Adapter CNA ports supporting both Ethernet and FCoE Delivers 80 Gbps total I O throughput to the server e VIC 1240 supports dual 4 x 10 Gbps Unified I O ports e VIC 1340 supports dual 4x 10 Gbps Unified I O ports or 2x40 native Gbps Unified I O ports Creates up to 256 fully functional unique and independent PCl
19. CS ML 1X324RU A_ 32GB DDR4 2133 MHz LRDIMM PC3 17000 quad rank x4 UCS MR 1X162RU A_ 16GB DDR4 2133 MHz RDIMM PC3 17000 dual rank x4 UCS MR 1X081RU A_ 8GB DDR4 2133 MHz RDIMM PC3 17000 single rank x4 Memory Mirroring Option N KR N O NO1 MMIRROR Memory mirroring option Notes 1 Power capping is not supported when using 64GB TSV RDIMMS Supported Configurations 1 1 CPU configuration without memory mirroring m Select from 1 to 12 DIMMs Refer to DIMM Population Rules on page 41 for more detailed information 12 Cisco UCS B200 M4 Blade Server CONFIGURING the SERVER 2 1 CPU configuration with memory mirroring m Select 2 4 8 or 12 identical DIMMs The DIMMs will be placed by the factory as shown in the following table Total CPU 1 DIMM Placement for identical DIMMs Number of Blue Slots Black Slots White Slots DIMMs 2 A1 B1 4 A1 B1 C1 D1 8 A1 B1 C1 D1 A2 B2 C2 D2 12 A1 B1 C1 D1 A2 B2 C2 D2 A3 B3 C3 D3 m Select the memory mirroring option N01 MMIRROR as shown in Table 4 on page 12 3 2 CPU configuration without memory mirroring m Select from 1 to 12 DIMMs per CPU Refer to DIMM Population Rules on page 41 for more detailed information 4 2 CPU configuration with memory mirroring m Select 2 4 8 or 12 identical DIMMs per CPU The DIMMs will be placed by the factory as shown in the following table Number CPU 1 DIMM Place
20. ECC DIMMs RDIMMs m Support for load reduced DIMMs LR DIMMs m Up to 1536 GB total memory capacity B200 M4 configured with two CPUs using 64 GB DIMMs Mezzanine adapters m One connector for Cisco s VIC 1340 or 1240 adapter which provides Ethernet and Fibre Channel over Ethernet FCoE NOTE The Cisco VIC 1200 Series 1240 and 1280 is compatible O in UCS domains that implement both 6100 and 6200 Series Fabric S Interconnects However the Cisco VIC 1300 Series 1340 and 1380 is compatible only with the 6200 Series Fabric Interconnects Storage controller m One connector for various types of Cisco adapters and Cisco UCS Storage Accelerator adapters Cisco FlexStorage 12G SAS RAID controller powered by the LSI SAS 3108 chip see http www Isi com products raid on chip pages lsi sas 3108 aspx with drive bays providing up to 12 Gbps SAS connectivity offering m SAS SATA support m RAID 0 and 1 and non RAID Cisco UCS B200 M4 Blade Server BASE SERVER STANDARD CAPABILITIES and FEATURES Table 1 Capabilities and Features continued Capability Feature Description Storage devices Video Interfaces Power subsystem Fans Integrated management processor m Up to two optional front accessible hot swappable 2 5 inch small form factor SFF SAS or SATA solid state disks SSDs or hard disk drives HDDs m An internal USB 2 0 port is also supported A 16 GB USB drive is available from
21. IGURING the SERVER STEP 12 CHOOSE SERVICE and SUPPORT LEVEL A variety of service options are available as described in this section Unified Computing Warranty No Contract If you have noncritical implementations and choose to have no service contract the following coverage is supplied Three year parts coverage Next business day NBD parts replacement eight hours a day five days a week 90 day software warranty on media Downloads of BIOS drivers and firmware updates UCSM updates for systems with Unified Computing System Manager These updates include minor enhancements and bug fixes that are designed to maintain the compliance of UCSM with published specifications release notes and industry standards Unified Computing Support Service For support of the entire Unified Computing System Cisco offers the Cisco Unified Computing Support Service This service provides expert software and hardware support to help sustain performance and high availability of the unified computing environment Access to Cisco Technical Assistance Center TAC is provided around the clock from anywhere in the world For UCS blade servers there is Smart Call Home which provides proactive embedded diagnostics and real time alerts For systems that include Unified Computing System Manager the support service includes downloads of UCSM upgrades The Unified Computing Support Service includes flexible hardware replacement options including repl
22. Ms 8 GB RDIMMs Notes 1 2133 MHz DIMMs are the only offered and supported DIMMs for the B200 M4 server m The B200 M4 server supports four different memory reliability availability and serviceability RAS modes Independent Channel Mode Mirrored Channel Mode Lockstep Channel Mode m Below are the system level RAS Mode combination limitations Mixing of Independent and Lockstep channel mode is not allowed per platform Mixing of Non Mirrored and Mirrored mode is not allowed per platform Mixing of Lockstep and Mirrored mode is not allowed per platform Do not mix RDIMMs with LRDIMMs Do not mix 64GB DDR4 2133 MHz TSV RDIMMs with any other DIMMs Single rank DIMMs can be mixed with dual rank DIMMs in the same channel Do not mix quad rank DIMMs with single or dual rank DIMMs in the same channel 14 Cisco UCS B200 M4 Blade Server CONFIGURING the SERVER m For best performance observe the following DIMMs with different timing parameters can be installed on different slots within the same channel but only timings that support the slowest DIMM will be applied to all As a consequence faster DIMMs will be operated at timings supported by the slowest DIMM populated When single dual or quad rank DIMMs are populated for 2DPC or 3DPC always populate the higher number rank DIMM first starting from the slot farthest from the CPU For a 3DPC example first populate with quad rank DIMMs in DIMM sl
23. P B01 CIMC SUP B02 CIMC SUP B10 CIMC SUP BASE K9 CIMC SUP TERM VMware 5 VMW VS5 STD 1A VMW VS5 STD 2A VMW VS5 STD 3A VMW VS5 STD 4A VMW VS5 STD 5A 30 UCS Performance Manager UCS Performance Manager Express UCS Performance Manager 60 days evaluation UCS Performance Manager Express 60 days evaluation UCS Performance Manager Not For Resale CS Performance Manager Express Not For Resale EVAL IMC Supervisor Branch Mgt SW for C E Series 50 Svrs EVAL IMC Supervisor One time Site Installation License IMC Supervisor Branch Mgt SW for C Series amp E Series up to 100 Svrs IMC Supervisor Branch Mgt SW for C Series amp E Series up to 250 Svrs IMC Supervisor Branch Mgt SW for C Series amp E Series up to 1K Svrs IMC Supervisor One time Site Installation License Acceptance of Cisco IMC Supervisor License Terms VMware vSphere 5 Standard for 1 Processor 1 Year Support Rqd VMware vSphere 5 Standard for 1 Processor 2 Year Support Rqd VMware vSphere 5 Standard for 1 Processor 3 Year Support Rad VMware vSphere 5 Standard for 1 Processor 4 Year Support Rqd VMware vSphere 5 Standard for 1 Processor 5 Year Support Rqd Cisco UCS B200 M4 Blade Server CONFIGURING the SERVER Table 13 OSs and Value Added Software for 2 CPU servers continued PID Description Product ID PID VMW VS5 ENT 1A VMware vSphere 5 Enterprise for 1 Processor 1 Year Support Rqd VMW VS5 ENT 2A VMware vSphere 5 Enterprise for 1 CPU 2 Yr
24. U in a B200 M4 configured with 2 CPUs CPU 2 controls the slot Therefore the only adapter that can be placed in the mezzanine slot in a B200 M4 configured with 1 CPU is the Cisco UCS Port Expander Card for VIC and the VIC 1340 1240 is always required to be installed in the mLOM slot Connectivity using the Cisco UCS 2208XP Fabric Extender The Cisco UCS 2208XP is the second generation Fabric Extender and shares the same form factor as the current UCS 2100 Series The 2208XP is backwards compatible with the UCS 5108 Blade server chassis The options shown in Figure 12 and Figure 13 demonstrate how the server uses these options m VIC 1340 1240 to 2208XP m VIC 1340 1240 plus Port Expander Card for VIC to 2208XP In Figure 12 two ports from the VIC 1340 1240 are channeled to 2208XP Fabric Extender A and two are channeled to 2208XP Fabric Extender B The result is 20 Gbps of bandwidth to each Fabric Extender Figure 12 Option 1 VIC 1340 1240 to UCS 2208XP Fabric Extender no mezzanine adapter Ej Port Group A Port Group B No Mezzanine Adapter Installed VIC 1340 1240 Adapter Mezzanine Slot mLOM Slot PCle x16 52 Cisco UCS B200 M4 Blade Server SUPPLEMENTAL MATERIAL In Figure 13 two ports from the VIC 1340 1240 are channeled to 2208XP Fabric Extender A and two are channeled to 2208XP Fabric Extender B The Port Expander Card for VIC installed in the mezzanine slot acts as a pass through device to ch
25. UCS B200 M4 Connections to the Fabric Extenders To Fabric Interconnects To Fabric Interconnects cc J e Mezzanine Adapter mezzanine slot mLOM slot B200 M4 Blade Server The B200 M4 server accommodates different types of adapter cards The mLOM slot only accommodates the VIC 1240 and VIC 1340 adapters while the mezzanine slot accommodates all other adapters such as port expander VIC 1280 1380 and Cisco adapters 48 Cisco UCS B200 M4 Blade Server SUPPLEMENTAL MATERIAL The network adapter options are m Cisco VIC 1340 1240 adapter This adapter plugs into the mLOM slot Both cards can support up to dual 4x10 Gbps ports requires Port Expander for VIC and 256 PCle devices The VIC 1340 is capable of supporting native 40 Gbps The capabilities of the adapter can easily be expanded by using the Port Expander Card for VIC in the mezzanine slot m Cisco VIC 1380 1280 Mezzanine adapter This adapter plugs into the mezzanine slot and is capable of up to dual 2x10 Gbps ports in the UCS B200 M4 server depending on the Fabric Extender chosen see Table 9 on page 23 and 256 PCle devices m Cisco Port Expander Card for VIC This I O expander plugs into the mezzanine slot and enables additional bandwidth to and from the server with the VIC 1340 1240 Using the Port Expander Card for VIC with the VIC 1340 1240 allows the compute blade to have up to dual 4x10 Gbps each depending on the Fabric Extender option chosen see Ta
26. acement in as little as two hours There is also access to Cisco s extensive online technical resources to help maintain optimal efficiency and uptime of the unified computing environment You can choose a desired service listed in Table 15 Table 15 Unified Computing Support Service Product ID PID On Site Description CON PREM B200M4 Yes ONSITE 24X7X2 UCS B200 M4 Blade Server CON OSP B200M4 Yes ONSITE 24X7X4 UCS B200 M4 Blade Server CON OSE B200M4 Yes ONSITE 8X5X4 UCS B200 M4 Blade Server CON OS B200M4 Yes ONSITE 8X5XNBD UCS B200 M4 Blade Server CON S2P B200M4 No SMARTNET 24X7X2 UCS B200 M4 Blade Server CON SNTP B200M4 No SMARTNET 24X7X4 UCS B200 M4 Blade Server CON SNTE B200M4 No SMARTNET 8X5X4 UCS B200 M4 Blade Server CON SNT B200M4 No SMARTNET 8X5XNBD UCS B200 M4 Blade Server Cisco UCS B200 M4 Blade Server 33 CONFIGURING the SERVER Unified Computing Warranty Plus Service For faster parts replacement than is provided with the standard Cisco Unified Computing System warranty Cisco offers the Cisco Unified Computing Warranty Plus Service You can choose from several levels of advanced parts replacement coverage including onsite parts replacement in as little as four hours Warranty Plus provides remote access any time to Cisco support professionals who can determine if a return materials authorization RMA is required You can choose a service listed in Table 16 Table 16 UCS Computing Warranty Plus Service Service On
27. anine connector The VIC 1340 and 1240 adapters are supported on both 1 and 2 CPU configured systems Cisco UCS B200 M4 Blade Server 21 CONFIGURING the SERVER Choose a Mezzanine Adapter The supported mezzanine adapters in the UCS B200 M4 are listed in Table 8 Table 8 Supported Mezzanine Adapters Product ID PID PID Description Virtual Interface Cards VICs UCSB MLOM 40G 03 UCSB VIC M83 8P UCSB MLOM 40G 012 UCS VIC M82 8P Cisco UCS VIC 1340 modular LOM for blade servers Cisco UCS VIC 1380 mezzanine adapter Cisco UCS VIC 1240 modular LOM for blade servers Cisco UCS VIC 1280 mezzanine adapter Cisco Storage Accelerators UCSB F FIO 1600MS UCSB F FIO 1300MP UCSB F FIO 785M UCSB F FIO 1300MP UCSB F FIO 1600MS UCS 1600 GB Fusion ioMemory3 SX Scale line for B Series UCS 1300 GB Fusion ioMemory3 PX Performance line for B Series Cisco UCS 785 GB MLC Fusion io ioDrive2 UCS 1300GB Fusion ioMemory3 PX Performance line for B Series UCS 1600GB Fusion ioMemory3 SX Scale line for B Series Port Expander Card for VIC Option UCSB MLOM PT 01 Notes Cisco UCS Port Expander Card for VIC This is a hardware option to enable an additional 4 ports of the VIC 1340 or VIC 1240 bringing the total capability of the VIC 1340 or VIC 1240 to dual 4 x 10 GbE Connector mMLOM Mezzanine mMLOM Mezzanine Mezzanine Mezzanine Mezzanine Mezzanine Mezzanine Mezzanine 1 The VIC 1340 1380 are only support
28. anking panels must be installed 16 Cisco UCS B200 M4 Blade Server CONFIGURING the SERVER Figure 4 UCS B200 M4 With and Without RAID Controller and Drive Bays Top View Shad dtd ada aetna ii oe vA FETE oe ei PAE ag az Jo a RAID Controller mail Pr F UF a bs Q a a a ae 1 it iP Deman eee Blanking Panels ee 2 a Server with RAID Controller and drive bays b Server with no RAID Controller or drive bays Figure 5 UCS B200 M4 With and Without RAID Controller hidden and Drives Front View Blanking Panels j ee d ff i oe ey a a h j H Sos e ae O F EFEFEF a Server with RAID Controller and drives Blanking Panel Cisco UCS B200 M4 Blade Server 17 CONFIGURING the SERVER STEP 5 CHOOSE HARD DISK DRIVES or SOLID STATE DRIVES OPTIONAL The UCS B200 M4 can be ordered with or without drives The standard disk drive features are m 2 5 inch small form factor Hot pluggable m Sled mounted Q NOTE The UCS B200 M4 blade server meets the external shared storage target SAN NAS and iSCSI and storage switch certifications as described in the following link http www cisco com en US docs switches datacenter mds9000 interoperabilit y matrix Matrix8 html wp323852 Choose Drives The supported drives in the UCS B200 M4 are listed in Table 7 Table 7 Supported Hot Pluggable Sled Mounted HDDs
29. annel two ports to each of the Fabric Extenders The result is 40 Gbps of bandwidth to each Fabric Extender Figure 13 Option 2 VIC 1340 1240 and Port Expander Card for VIC to UCS 2208XP Port Expander Mezzanine Adapter Cisco UCS B200 M4 Blade Server 53 54 SUPPLEMENTAL MATERIAL Connectivity using the Cisco UCS 2204XP Fabric Extender The Cisco UCS 2204XP is a second generation Fabric Extender and shares the same form factor as the current UCS 2100 Series The 2204XP is backwards compatible with the UCS 5108 Blade serve chassis The options shown in Figure 14 and Figure 15 demonstrate how the server uses these options m VIC 1340 1240 to 2204XP m VIC 1340 1240 plus Port Expander Card for VIC to 2204XP In Figure 14 one port from the VIC 1340 1240 is channeled to 2204XP Fabric Extender A and one is channeled to 2204XP Fabric Extender B The result is 10 Gbps of bandwidth to each Fabric Extender Figure 14 Option 1 VIC 1340 1240 to UCS 2204XP Fabric Extender no mezzanine adapter 2 2 2 Port Group A Port Group B No Mezzanine Adapter Installed VIC 1340 1240 Ada pter Mezzanine Slat mLOM Slot Pile x16 Cisco UCS B200 M4 Blade Server SUPPLEMENTAL MATERIAL In Figure 15 one port from the VIC 1340 1240 is channeled to 2204XP Fabric Extender A and one is channeled to 2204XP Fabric Extender B The Port Expander Card for VIC installed in the mezzanine slot acts as a pass through device to channel one p
30. ble 9 on page 23 m Cisco Storage Accelerators plug into the mezzanine slot These flash storage devices do not have network connectivity instead they provide independent high speed storage controlled by CPU 2 See Table 8 on page 22 for descriptions NOTE The bandwidth port count on these adapters depends on the Fabric O Extender For example the VIC 1380 1280 only supports up to 4x10 Gbps in this SS blade because each mezzanine slot or mLOM slot only supports up to 4x10 Gbps VIC 1340 1240 Adapter The only adapter that can be plugged in to the mLOM slot is the VIC 1340 1240 Cisco designed PCle based adapters that provide up to eight depending on the Fabric Extender option chosen 10 Gigabit Data Center Ethernet DCE network interfaces There are two groups of four ports on the VIC 1340 1240 Two ports of the first group and two ports of the second group are wired through the UCS 5108 Blade Server chassis to Fabric Extender A and Fabric Extender B The other two ports of each group are wired to the mezzanine slot as represented in Figure 11 Cisco UCS B200 M4 Blade Server 49 SUPPLEMENTAL MATERIAL Figure 11 VIC 1340 1240 Port Connectivity THE Variable of ports depends on mezz adapter type Port Group A Port Group B Mezzanine Adapter VIC 1340 1240 Adapter Mezzanine Slot PCle x16 PCle x16 OPI Link The number of ports available at the mezzanine adapter depends on the type of mez
31. e 3 UCS B200 M4 Memory Organization Slot 3 Slot 2 Slot 1 E3 E2 El Chan E Chan F QPI Links Chan G Chan H 24 DIMMS 1536 GB maximum memory with 64 GB DIMMs 4 memory channels per CPU up to 3 DIMMs per channel Cisco UCS B200 M4 Blade Server 11 CONFIGURING the SERVER Choose DIMMs and Memory Mirroring Select the memory configuration and whether or not you want the memory mirroring option The supported memory DIMMs and the mirroring option are listed in Table 4 NOTE When memory mirroring is enabled the memory subsystem simultaneously writes identical data to two adjacent channels If a memory read from one of the channels returns incorrect data due to an uncorrectable memory error the system automatically retrieves the data from the other channel A transient or soft error in one channel does not affect the mirrored data and operation continues unless there is a simultaneous error in exactly the same location on a DIMM and its mirrored DIMM Memory mirroring reduces the amount of memory available to the operating system by 50 because only one of the two populated channels provides data Q The supported memory DIMMs in the UCS B200 M4 are listed in Table 4 Table 4 Available DDR4 DIMMs Product ID PID PID Description Voltage Ranke DIMM DIMM Options UCS MR 1X648RU A1 64GB DDR4 2133 MHz TSV RDIMM PC4 17000 octal rank x4 UCS ML 1X322RU A_ 32GB DDR4 2133 MHz RDIMM PC4 17000 dual rank x4 U
32. e adapters and interfaces NICs or HBAs without requiring single root I O virtualization SR IOV support from operating systems or hypervisors Provides virtual machine visibility from the physical network and a consistent network operations model for physical and virtual servers Supports customer requirements for a wide range of operating systems and hypervisors m Cisco UCS Storage Accelerator Adapters Cisco UCS Storage Accelerator adapters are designed specifically for the Cisco UCS B Series M3 blade servers and integrate seamlessly to allow improvement in performance and relief of I O bottlenecks 20 Cisco UCS B200 M4 Blade Server CONFIGURING the SERVER NOTE For environments with 6100 Series Fabric Interconnects you must configure only the VIC 1240 1280 adapters 1200 Series and not 1340 1380 1300 Series From an I O connectivity standpoint configure only the VIC 1200 Series with the 6100 Series Fabric Interconnects NOTE There are two slots on the server One is a dedicated slot for the VIC 1340 1240 adapter only and one accommodates Cisco adapters or Cisco Storage Accelerator adapters as well as other options Table 8 shows which adapters plug into each of the two slots Only the VIC 1340 or 1240 adapter plugs into the VIC 1340 1240 adapter slot All other adapters plug into the mezzanine adapter slot NOTE You must have a B200 M4 configured with 2 CPUs to support cards that plug into the mezz
33. e four memory channels These configurations are possible but not recommended due to poor performance Cisco UCS B200 M4 Blade Server 43 SUPPLEMENTAL MATERIAL Additional DIMM Populations The list in Table 25 is not a complete list of all supported DIMM populations but highlights common configuration options Table 25 Supported DIMM Configurations CPU 1 DIMMs Pere Paha CPU 2 DIMMs Doesnt ba capacity for S 1x8 GB 1 8GB 1x8GB 1 8 GB 16 GB 2 x 8 GB 2 16GB 2x8GB 2 16 GB 32 GB 1x16 GB 1 16GB 1x16GB 1 16 GB 32 GB 4x8 GB 4 32GB 4x8GB 4 32 GB 64 GB 2 x 16 GB 2 32GB 2x 16GB 2 32 GB 64 GB 1x 32GB 1 32GB 1x32GB 1 32 GB 64 GB 8 x 8 GB 8 64GB 8x8GB 8 64 GB 128 GB 4x16 GB 4 64GB 4x16GB 4 64 GB 128 GB 2 x 32 GB 2 64GB 2x32GB 2 64 GB 128 GB 12 x 8 GB 12 96GB 12x8GB 12 96 GB 192 GB 6 x 16 GB 6 96GB 6x16GB 6 96 GB 192 GB 8 x 16 GB 8 128GB 8x16 GB 128 GB 256 GB 4 x 32 GB 4 128GB 4x32 GB 4 128 GB 256 GB 12 x 16 GB 12 192GB 12x16 GB 12 192 GB 384 GB 6 x 32 GB 6 192 GB 6x32 GB 6 192 GB 384 GB 8 x 32 GB 8 256GB 8x 32GB 8 256 GB 512 GB 12 x 32 GB 12 384GB 12x32 GB 12 384 GB 768 GB 12 x 64 GB 12 768 GB 12x 64GB 12 768 GB 1536 GB 44 Cisco UCS B200 M4 Blade Server SUPPLEMENTAL MATERIAL Upgrade and Servicing Related Parts This section lists the upgrade and servicing related parts you may need during the life of your UCS B200 M4 server Some of these parts are configured with every server or with every UCS 5108 blade server chassis and s
34. ed with the 6200 Series Fabric Interconnects They are not supported with the 6100 Series Fabric Interconnects 2 The VIC 1240 1280 are supported with both the 6200 and 6100 Series Fabric Interconnects 3 Do not mix Fusion io storage accelerator families That is do not mix MP or MS ioMemory3 with M ioDrive2 family cards 22 Cisco UCS B200 M4 Blade Server CONFIGURING the SERVER Supported Configurations The supported configurations are listed in Table 9 Choose one configuration Refer to B200 M4 Configured with 1 CPU on page 52 and B200 M4 Configured with 2 CPUs on page 57 for more details Table 9 Supported B200 M4 I O Configurations Fabric Extenders Aggregate Adapter Configurations Fabric Interconnects CPU Dependency Bandwidth Adapter Adapter Slot 2 2x 2x 2x 2 x 61xx 2 x 62xx Slot 1 2208XP 2204XP 2104XP1 Notes not populated Port Expander Card for VIC VIC 1380 non lO mezz for example Fusion io not populated Port Expander Card for VIC VIC 1280 non lO mezz for example Fusion io 40 Gb s 80 Gb s 80 Gb s 40 Gb s 40 Gb s 80 Gb s 80 Gb s 40 Gb s 20 Gb s 40 Gb s 40 Gb s 20 Gb s 20 Gb s 40 Gb s 40 Gb s 20 Gb s 1 or 2 CPUs 1 or 2 CPUs Requires 2 CPUs Requires 2 CPUs 1 or 2 CPUs lO card in 61xx 1 or 2 CPUs ignored lO card in 61xx slot 2 ignored 20 Gb s Requires 2 CPUs Requires 2 CPUs
35. g VIC generations is not allowed do not mix VIC 1380 with VIC 1240 or VIC 1280 with VIC 1340 In Figure 19 two ports from the VIC 1340 1240 are channeled to 2208XP Fabric Extender A and two are channeled to 2208XP Fabric Extender B The Port Expander Card for VIC installed in the mezzanine slot acts as a pass through device to channel two ports to each of the Fabric Extenders The result is 40 Gbps of bandwidth to each Fabric Extender Figure 19 Option 3 VIC 1340 1240 and Port Expander Card for VIC to UCS 2208XP FEX foe Port Group B Port Expander Mezzanine Adapter Mezzanine Slat P le 216 OPI Link 58 Cisco UCS B200 M4 Blade Server SUPPLEMENTAL MATERIAL Connectivity using the Cisco UCS 2204XP Fabric Extender The Cisco UCS 2204XP is a second generation Fabric Extender and shares the same form factor as the current UCS 2100 Series The 2204XP is backwards compatible with the UCS 5108 Blade serve chassis The options shown in Figure 20 through Figure 22 demonstrate how the server uses these options m VIC 1340 1240 to 2204XP m VIC 1340 1240 and VIC 1380 1280 to 2204XP m VIC 1340 1240 plus Port Expander Card for VIC to 2204XP NOTE A Cisco Storage Accelerator adapter may also be plugged into the mezzanine adapter There is no network connectivity for this kind of adapter instead it provides high speed storage to the system and is controlled by CPU 2 2 In Figure 20 one port fr
36. he Fabric Extenders The result is 20 Gbps of bandwidth to each Fabric Extender Figure 22 Option 3 VIC 1340 1240 and Port Expander Card for VIC to UCS 2204XP FEX me a hel el bal Port Group A Port Group B Port Expander Adapter VIC 1340 1240 Adapter mLOM Shot PCle x16 OPI Link 60 Cisco UCS B200 M4 Blade Server SUPPLEMENTAL MATERIAL Connectivity using the Cisco UCS 2104XP Fabric Extender The options shown in Figure 23 and Figure 24 demonstrate how the UCS B200 M4 blade server connects to a UCS 2104XP Fabric Extender With this option the mezzanine connector can either be empty or contain an independent Cisco Storage Accelerator adapter that communicates with CPU 2 through the PCle bus In Figure 23 one port from the VIC 1240 is channeled to 2104XP Fabric Extender A and one is channeled to 2104XP Fabric Extender B The result is 10 Gbps of bandwidth to each Fabric Extender With this option no adapter is located in the mezzanine connector Figure 23 Option 1 VIC 1240 to UCS 2104XP Fabric Extender no mezzanine adapter Port Group A Port Group B No Mezzanine Adapter Installed VIC 1240 Adapter In Figure 24 one port from the VIC 1240 is channeled to 2104XP Fabric Extender A and one is channeled to 2104XP Fabric Extender B The result is 10 Gbps of bandwidth to each Fabric Extender The Cisco Storage Accelerator adapter is located in the mezzanine connector as an independent de
37. it Instructions for applying thermal grease are found at http www cisco com c en us td docs unified_computing ucs hw blade servers B200M4 htmll CAUTION Use only the thermal grease specified for this server UCS CPU GREASE3 This thermal grease comes in a white tipped syringe DO NOT use thermal grease available for purchase at any commercial electronics store If these instructions are not followed the CPU may overheat and be destroyed Q NOTE When you purchase a spare CPU the thermal grease with syringe applicator is included Air Baffle Replacement Kit Air baffles are designed to direct airflow through the server to maintain server temperature at a safe operating level The UCS B200 M4 server comes shipped with two identical air baffles covering the DIMM socket areas of the server These baffles must always remain installed during server operation The Air Baffle Replacement Kit includes the two identical air baffles needed for one UCS B200 M4 server For instructions on how to remove and replace the air baffles see the following link http www cisco com c en us td docs unified_computing ucs hw blade servers B200M4 html 46 Cisco UCS B200 M4 Blade Server SUPPLEMENTAL MATERIAL CPU Heat Sink Cleaning Kit The cleaning kit is used to remove the existing thermal compound from the bottom of the heat sink during a CPU replacement process Instructions for cleaning are found at the following link ht
38. ment CPU 2 DIMM Placement of DIMMs for identical DIMMs for identical DIMMs P penca Blue Slots Black Slots White Slots Blue Slots Black Slots White Slots A1 B1 E1 F1 A1 B1 E1 F1 C1 D1 G1 H1 8 CPU1 A1 B1 A2 B2 E1 F1 E2 F2 and 4 C1 D1 C2 D2 CPU2 8 A1 B1 A2 B2 E1 F1 E2 F2 2 C1 D1 C2 D2 G1 H1 G2 H2 12 A1 B1 C1 D1 A2 B2 C2 D2 A3 B3 E1 F1 E2 F2 E3 F3 C3 D3 G1 H1 G2 H2 G3 H3 Notes 1 Not recommended for performance reasons Cisco UCS B200 M4 Blade Server 13 CONFIGURING the SERVER m Select the memory mirroring option NO1 MMIRROR as shown in Table 4 on page 12 Q NOTE System performance is optimized when the DIMM type and quantity are equal for both CPUs and when each populated channel is filled completely equally across the CPUs in the server Caveats m System speed is dependent on how many DIMMs are populated per channel and the CPU DIMM speed support See Table 5 for details Table 5 DIMM Memory Speeds with Different CPUs 1600 MHz 1600 MHz Capable CPU CPU 1866 MHz 1866 MHz Capable CPU CPU 2133 MHz 2133 MHz Capable CPU CPU DIMM Speed DPC RDIMM boise RDIMM a RDIM IER DRIER QR 8R DR SR QR 8R DR SR QR 2133 DIMM 1DPC 1600 1866 1866 2133 2DPC 1600 1866 1866 2133 3DPC 1600 1600 1600 1866 32 GB RDIMMs and 16 GB DIMMs 1600 64 GB TSV RDIM
39. nector on the motherboard Cisco UCS B200 M4 Blade Server 27 CONFIGURING the SERVER where you can look to make sure the USB drive is fully inserted into the USB NOTE The figures below show a peephole provided on the RAID controller board Sz connector Sia Peephole a USB drive plugged into connector a b USB drive unplugged from connector 28 Cisco UCS B200 M4 Blade Server CONFIGURING the SERVER STEP 10 CHOOSE OPERATING SYSTEM AND VALUE ADDED SOFTWARE Several operating systems and value added software programs are available Select as desired from Table 13 Table 13 OSs and Value Added Software for 2 CPU servers PID Description Cisco One C1F2PUCSK9 C1F2SICFBK9 C1A1PUCSK9 C1UCS OPT OUT Product ID PID Cisco ONE Foundation Perpetual UCS Cisco ONE Foundation Subsr Intercloud Fabric For Business Cisco ONE Enterprise Cloud Perpetual UCS Cisco One Data Center Compute Opt Out Option Microsoft Windows Server MSWS 12 ST2S MSWS 12 DC2S MSWS 12 ST2S NS MSWS 12 DC2S NS MSWS 12R2 ST2S MSWS 12R2 DC2S MSWS 12R2 ST2S NS MSWS 12R2 DC2S NS SUSE SLES 2S2V 1A SLES 2S2V 3A SLES 2S2V 5A SLES 2SUV 1A SLES 2SUV 3A SLES 2SUV 5A SLES 2S HA 1 S SLES 2S HA 3A SLES 2S HA 5A SLES 2S GC 15S SLES 2S GC 35S SLES 2S GC 5S SLES SAP 2S2V 1A SLES SAP 2S2V 3A SLES SAP 2S2V 5A SLES SAP 2SUV 1A SLES SAP 2SUV 3A SLES SAP 2SUV 5A Windows Server 2012 Standard 2 CPU 2 VMs
40. om the VIC 1340 1240 is channeled to 2204XP Fabric Extender A and one is channeled to 2204XP Fabric Extender B The result is 10 Gbps of bandwidth to each Fabric Extender Figure 20 Option 1 VIC 1340 1240 to UCS 2204XP Fabric Extender no mezzanine adap E u bel on ter m aTa Fort Group A Port Group B No Mezzanine Adapter Installed VIC 1340 1240 Adapter Mezzanine Slat mLOM Slat Pile x16 QF Link Cisco UCS B200 M4 Blade Server 59 SUPPLEMENTAL MATERIAL In Figure 21 one port from the VIC 1340 1240 is channeled to 2204XP Fabric Extender A and one is channeled to 2204XP Fabric Extender B The VIC 1380 1280 installed in the mezzanine slot also channels one port to each of the Fabric Extenders The result is 20 Gbps of bandwidth to each Fabric Extender Figure 21 Option 2 VIC 1340 1240 and VIC 1380 1280 to UCS 2204XP Fabric Extender Port Group A Port Group B Port Group A VIC 1380 1280 Adapter VIC 1340 1240 Adapter mLOM Slot PCla x16 Gen 3 Mezzanine Slat PCle x16 Gen 3 OPI Link Note mixing VIC generations is not allowed do not mix VIC 1380 with VIC 1240 or VIC 1280 with VIC 1340 In Figure 22 one port from the VIC 1340 1240 is channeled to 2204XP Fabric Extender A and one is channeled to 2204XP Fabric Extender B The Port Expander Card for VIC installed in the mezzanine slot acts as a pass through device to channel one port to each of t
41. ome may be ordered when needed or may be ordered and kept on hand as spares for future use See Table 26 Table 26 Upgrade and Servicing related Parts for UCS B200 M4 Server Spare Product ID PID Description N20 BBLKD 2 5 inch HDD Blanking Panel N20 CBLKB1 Blade slot blanking panel for UCS 5108 single slot UCSB HS EP M4 F CPU Heat Sink for UCS B200 M4 socket 1 front UCSB HS EP M4 R CPU Heat Sink for UCS B200 M4 socket 1 rear UCS CPU LPCVR CPU load plate dust cover for unpopulated CPU sockets UCSB BAFF B200 M4 Air Baffle Replacement Kit for B200 M4 Server N20 MBLIBAT T Replacement Lithium Battery for Server Motherboard CR2032 N20 BKVM KVM local IO cable for UCS servers console port UCS CPU GREASE3 CPU thermal grease syringe needed for heatsink seal UCSX HSCK UCS Processor Heat Sink Cleaning Kit when replacing a CPU Notes 1 This part is included configured with your UCS server in some cases as determined by the configuration of your server 2 This part is included configured with the UCS 5108 blade server chassis 3 This part is included with the purchase of each optional or spare Intel Xeon E5 2600 v3 CPU processor kit Drive and Blade Server Blanking Panels A drive blanking panel N20 BBLKD must be installed if you remove a disk drive from a UCS server Similarly a blade server blanking panel N20 CBLKB1 must be installed if you remove a half width blade server such as a UCS B200 M4 serve
42. on page 39 The 12 DIMM slots at the left are controlled by CPU 1 and the 12 DIMM slots on the right are controlled by CPU 2 DIMM Population Rules When considering the memory configuration take into account the following m Each channel has three DIMM slots for example channel A slots A1 A2 and A3 A channel can operate with one two or three DIMMs installed If a channel has only one DIMM populate slot 1 first the blue slot m When both CPUs are installed populate the DIMM slots of each CPU identically Fill blue slots in the channels first A1 E1 B1 F1 C1 G1 D1 H1 Fill black slots in the channels second A2 E2 B2 F2 C2 G2 D2 H2 Fill white slots in the channels third A3 E3 B3 F3 C3 G3 D3 H3 m Any DIMM installed in a DIMM socket for which the CPU is absent is not recognized m Observe the DIMM mixing rules shown in Table 22 Table 22 DIMM Rules for B200 M4 Servers DIMM Parameter DIMMs in the Same Channel DIMM in the Same Slot DIMM Capacity RDIMM 8 16 or 64 GB DIMMs in the same channel for For best performance DIMMs in the LRDIMM 32 GB example A1 A2 and A3 can have same slot for example A1 B1 C1 different capacities D1 should have the same capacity Do not mix LRDIMMs with RDIMMs Do not mix LRDIMMs with RDIMMs DIMM Speed 2133 MHz DIMMs will run at the lowest speed DIMMs will run at the lowest speed of of the CPU installed the CPU installed DIMM Type RDIMM
43. options m VIC 1340 1240 to 2208XP m VIC 1340 1240 and VIC 1380 1280 to 2208XP m VIC 1340 1240 plus Port Expander Card for VIC to 2208XP NOTE A Cisco Storage Accelerator adapter may also be plugged into the mezzanine adapter There is no network connectivity for this kind of adapter instead it provides high speed storage to the system and is controlled by CPU 2 In Figure 17 two ports from the VIC 1340 1240 are channeled to 2208XP Fabric Extender A and two are channeled to 2208XP Fabric Extender B The result is 20 Gbps of bandwidth to each Fabric Extender Figure 17 Option 1 VIC 1340 1240 to UCS 2208XP Fabric Extender no mezzanine adapter Port Group A Port Group B No Mezzanine Adapter Installed VIC 1340 1240 Adapter Mezzanine Slot m Td PCle x16 OFI Link Cisco UCS B200 M4 Blade Server 57 SUPPLEMENTAL MATERIAL In Figure 18 two ports from the VIC 1340 1240 are channeled to 2208XP Fabric Extender A and two are channeled to 2208XP Fabric Extender B The VIC 1380 1280 installed in the mezzanine slot also channels two ports to each of the Fabric Extenders The result is 40 Gbps of bandwidth to each Fabric Extender Figure 18 Option 2 VIC 1340 1240 and VIC 1380 1280 to UCS 2208XP Fabric Extender Lully Port Group A Port Group B Port Group A VIC 1380 1280 Adapter VIC 1340 1240 Adapter Mezzanine Slot PCle x16 PCle x16 OPI Link Note mixin
44. ort to each of the Fabric Extenders The result is 20 Gbps of bandwidth to each Fabric Extender Figure 15 Option 2 VIC 1340 1240 and Port Expander Card for VIC to UCS 2204XP Fabric Extender The he Port Group A Port Group B Port Expander Adapter VIC 1340 1240 Adapter E m 10GKR_ H mLOM Slot Mezzanine Slot Ple x16 Cisco UCS B200 M4 Blade Server 55 56 SUPPLEMENTAL MATERIAL Connectivity using the Cisco UCS 2104XP Fabric Extender The option shown in Figure 16 demonstrates how the UCS B200 M4 blade serves connects to a UCS 2104XP Fabric Extender In Figure 16 one port from the VIC 1240 is channeled to 2104XP Fabric Extender A and one is channeled to 2104XP Fabric Extender B The result is 10 Gbps of bandwidth to each Fabric Extender Figure 16 i 2 2 Option 1 VIC 1240 to UCS 2104XP Fabric Extender no mezzanine adapter Port Group A Port Group B No Mezzanine Adapter Installed VIC 1240 Adapter Mezzanine Slot mLOM Set PCle x16 Cisco UCS B200 M4 Blade Server SUPPLEMENTAL MATERIAL B200 M4 Configured with 2 CPUs Connectivity using the Cisco UCS 2208XP Fabric Extender The Cisco UCS 2208XP is the second generation Fabric Extender and shares the same form factor as the current UCS 2100 Series The 2208XP is backwards compatible with the UCS 5108 Blade serve chassis The options shown in Figure 17 through Figure 19 demonstrate how the server uses these
45. ot 1 Then dual rank DIMMs in DIMM slot 2 Then single rank DIMMs in DIMM slot 3 m DIMMs for CPU 1 and CPU 2 when populated must always be configured identically m When using mirroring DIMMs must be installed in identical pairs across paired DDR4 buses That is mirrored pairs in channels A and B must be identical and pairs in channels C and D must be identical However the DIMMs used in channels A and B can be different from those in channels C and D m Pairs of DIMMs A1 B1 A2 B2 etc must be the exact same same PID and DIMM loading order m Cisco memory from previous generation servers DDR3 is not compatible with this server For more information regarding memory see CPUs and DIMMs on page 40 Cisco UCS B200 M4 Blade Server 15 CONFIGURING the SERVER STEP 4 CHOOSE RAID CONTROLLER AND DISK DRIVE BAYS The UCS B200 M4 can be ordered with or without the Cisco FlexStorage RAID controller with disk drive bays local storage subsystem There is no RAID or local storage controller or drive bays included embedded with the B200 M4 server Therefore a Cisco FlexStorage RAID controller with drive bays must be purchased in order to support any 1 or 2 local hard disk drives HDDs or solid state drives SSDs Either Cisco FlexStorage RAID controller supports RAID O and 1 as well as non RAID ed configurations For servers that will not need any local HDDs or SSDs for example for booting from SAN you can order the server
46. pport Reqd SLES for SAP Applications 1 2 CPU Unl Vrt 5yr Support Reqd Cisco UCS B200 M4 Blade Server 29 CONFIGURING the SERVER Table 13 OSs and Value Added Software for 2 CPU servers continued Product ID PID PID Description Red Hat Enterprise Linux RHEL 2S 1G 1A RHEL 2S 1G 3A RHEL HA 2S 1A RHEL HA 2S 3A RHEL RS 2S 1A RHEL RS 2S 3A RHEL SFS 2S 1A RHEL SFS 2S 3A RHEL 2 Socket 1 Guest 1Yr Svcs Required RHEL 2 Socket 1 Guest 3Yr Svcs Required RHEL Option High Availability 2 Socket 1Yr Svcs Required RHEL Option High Availability 2 Socket 3Yr Svcs Required RHEL Option Resilient w Ha 2 Socket 1 Yr Svcs Required RHEL Option Resilient Storage w HA 2 Socket 3 Yr Svcs Reqd RHEL Option Scalable File System 2 Socket 1 Yr Svcs Required RHEL Option Scalable File System 2 Socket 1 Yr Svcs Required Nexus 1000V for Hyper V and vSphere N1K VSG UCS BUN N1K VLEM UCS 1 VSG VLEM UCS 1 UCS Director CUIC PHY SERV BM U CUIC PHY SERV U CUIC TERM Over half off N1K and VSG w purchase of UCS B C Series Nexus 1000V License Paper Delivery 1 CPU for bundles VSG License Paper Delivery 1 CPU for bundles Cisco Cloupia Resource Lic One Phy Server node bare metal Cisco Cloupia Resource Lic One physical Server node Acceptance of Cisco Cloupia License Terms UCS Performance Manager UCS PM IE UCS PM EE EVAL UCS PM IE EVAL UCS PM EE NFR UCS PM IE NFR UCS PM EE IMC Supervisor EVAL CIMC SUP EVAL CIMC SUP BAS CIMC SU
47. r from a blade server chassis If no FlexStorage RAID controller module is used the FlexStorage blanking panels UCSB LSTOR BK must be installed These panels are required to maintain system temperatures at safe operating levels and to keep dust away from system components Cisco UCS B200 M4 Blade Server 45 SUPPLEMENTAL MATERIAL Adding an Additional CPU with CPU heat sink or Replacing CPUs All Cisco UCS two CPU socket capable servers can be upgraded from having one to having two CPUs configured or can also support replacement of the CPUs You will need to order and install a heat sink when adding any additional CPU to a server Instructions for installing the new CPU or replacing CPUs and heat sink can be found at the following link http www cisco com c en us td docs unified_computing ucs hw blade servers B200M4 html O NOTE Unlike previous generation servers the B200 M4 has tool less CPU sockets so Se no separate tools such as pick n place tools are required to add or replace CPUs Motherboard Lithium Battery You can order a replacement motherboard battery Installation instructions are found at this link http www cisco com c en us td docs unified_computing ucs hw blade servers B200M4 html Thermal Grease with syringe applicator for CPU to Heatsink Seal Thermal grease must be applied to the top of the CPU where it comes in contact with the heat sink a grease syringe also ships with each CPU spare option k
48. rapidly identifying and addressing issues m Strengthen in house expertise through knowledge transfer and mentoring a Improve operational efficiency by allowing UCS experts to augment your internal staff resources Enhance business agility by diagnosing potential issues before they affect your operations Cisco UCS B200 M4 Blade Server 35 CONFIGURING the SERVER You can choose a service listed in Table 19 Table 19 UCS Computing Combined Support Service Service On Product ID PID Level 3 Description Site GSP CON NCF2 B200M4 NCF2 No CMB SPT SVC 24X7X2 UCS B200 M4 Blade Server CON NCF2P B200M4 NCF2P Yes CMB SPT SVC 24X7X2O0S UCS B200 M4 Blade Server CON NCF4P B200M4 NCF4P Yes CMB SPT SVC 24X7X40S UCS B200 M4 Blade Server CON NCF4S B200M4 NCF4S Yes CMB SPT SVC 8X5X4OS UCS B200 M4 Blade Server CON NCFCS B200M4 NCFCS Yes CMB SPT SVC 8X5XNBDOS UCS B200 M4 Blade Server CON NCFE B200M4 NCFE No CMB SPT SVC 8X5X4 UCS B200 M4 Blade Server CON NCFP B200M4 NCFP No CMB SPT SVC 24X7X4 UCS B200 M4 Blade Server CON NCFT B200M4 NCFT No CMB SPT SVC 8X5XNBD UCS B200 M4 Blade Server Unified Computing Drive Retention Service With the Cisco Unified Computing Drive Retention UCDR Service you can obtain a new disk drive in exchange for a faulty drive without returning the faulty drive In exchange for a Cisco replacement drive you provide a signed Certificate of Destruction CoD confirming that the drive has been removed from the sys
49. s or LRDIMMs Do not mix DIMM types in a channel Do not mix DIMM types in a slot 1 DPC 2 DPC or 3 DPC DIMMs per Channel DPC See Table 5 on page 14 for valid LRDIMM and RDIMM 1 DPC 2 DPC and 3 DPC memory configurations Notes 1 Although different DIMM capacities can exist in the same slot this will result in less than optimal performance For optimal performance all DIMMs in the same slot should be identical Cisco UCS B200 M4 Blade Server 41 SUPPLEMENTAL MATERIAL DIMM Population Order Populate the DIMMs for a CPU according to Table 23 See also Figure 9 Table 23 DIMM Population Order per CPU DIMMs Populate Populate per CPU CPU 1 Slots CPU 2 Slots 1 A1 E1 2 A1 B1 E1 F1 3 A1 B1 C1 E1 F1 G1 4 A1 B1 C1 D1 E1 F1 G1 H1 61 A1 B1 C1 E1 F1 G1 A2 B2 C2 E2 F2 G2 8 A1 B1 C1 D1 E1 F1 G1 H1 A2 B2 C2 D2 E2 F2 G2 H2 12 A1 B1 C1 D1 E1 F1 G1 H1 A2 B2 C2 D2 E2 F2 G2 H2 A3 B3 C3 D3 E3 F3 G3 H3 Notes 1 Not recommended for performance reasons Figure 9 DIMM Population Order DIMM Population Order DIMMs for CPU 1 DIMMs for CPU 2 Install in Slots Install in Slots Blue Blue Blue and Black Blue and Black Blue Black and White Blue Black and White 42 Cisco UCS B200 M4 Blade Server SUPPLEMENTAL MATERIAL Recommended Memory Configuration This section explains the recommended DIMM population order rules for the B200 M4 blades
50. sor for a total of up to 36 cores per server Select CPUs The available CPUs are listed in Table 3 Table 3 Available Intel CPUs E5 2600 v3 Series Processor Family CPUs Product ID PID UCS CPU E52699D UCS CPU E52698D UCS CPU E52697D UCS CPU E52695D UCS CPU E52690D UCS CPU E52683D UCS CPU E52680D UCS CPU E52670D UCS CPU E52667D UCS CPU E52660D UCS CPU E52658D UCS CPU E52650D UCS CPU E52650LD UCS CPU E52643D UCS CPU E52640D UCS CPU E52637D UCS CPU E52630D UCS CPU E52630LD UCS CPU E52623D UCS CPU E52620D UCS CPU E52609D2 Notes Intel Number E5 2699 v3 E5 2698 v3 E5 2697 v3 E5 2695 v3 E5 2690 v3 E5 2683 v3 E5 2680 v3 E5 2670 v3 E5 2667 v3 E5 2660 v3 E5 2658 v3 E5 2650 v3 E5 2650L v3 E5 2643 v3 E5 2640 v3 E5 2637 v3 E5 2630 v3 E5 2630L v3 E5 2623 v3 E5 2620 v3 E5 2609 v3 145 135 145 120 135 120 120 120 135 105 105 105 65 135 90 135 85 59 105 85 85 Cache Size MB 45 40 35 35 30 35 30 30 20 25 30 25 30 20 20 15 20 20 10 15 15 Cores Oo OA CO CO LK o QPI 9 6 GT s 9 6 GT s 9 6 GT s 9 6 GT s 9 6 GT s 9 6 GT s 9 6 GT s 9 6 GT s 9 6 GT s 9 6 GT s 9 6 GT s 9 6 GT s 9 6 GT s 9 6 GT s 8 0 GT s 9 6 GT s 8 0 GT s 8 0 GT s 8 0 GT s 8 0 GT s 6 4 GT s Highest DDR4 DIMM Clock Support MHz 2133 2133 2133 2133 2133 2133 2133 2133 2133 2133 2133 2133 1866 2133 1866 2133 1866 1866 1866 1866 16
51. stfeontas Spec Sheet cisco Cisco UCS B200 M4 Blade Server Cisco SYSTEMS PUBLICATION HISTORY 170 WEST TASMAN DR SAN JOSE CA 95134 REV B 3 JULY 2 2015 WWW CISCO COM CONTENTS OVERVIEW G4e a0 ENS ERE Ca CREE Eee ea ae eo oe DETAILED VIEWS niron ew eo ee ee a unAn aA Blade Server Front View sese e ecw ee wee wee eee eee et ew ee ee ee ee CONFIGURING the SERVER 0c c ee eee 4 4 BASE SERVER STANDARD CAPABILITIES and FEATURES 0000000 00295 7 8 9 STEP 1 VERIFY SERVER OAU o oo se oy oo a eee os oe ee ee ee oe eee 8 ee ee es SIEP 2 CHOOSE CPU eco hee eek ea echers ee aa eee oes oa ee bee ee ee ees SIEP 3 CHOOSE MEMORY 2a 5444 0054504 oa eae eee 65a Ges bate eee eee es 11 STEP 4 CHOOSE RAID CONTROLLER AND DISK DRIVE BAYS 202 0000 eee 16 STEP 5 CHOOSE HARD DISK DRIVES or SOLID STATE DRIVES OPTIONAL 18 SIEP G CHOOSE ADAPTERS uc pe daa case sore ee eed Bes chtat E N oe 20 STEP 7 ORDER TRUSTED PLATFORM MODULE OPTIONAL 0200 000 25 STEP 8 ORDER SECURE DIGITAL CARDS OPTIONAL 2 0 00 ee eee eens 26 STEP 9 ORDER INTERNAL USB 2 0 DRIVE OPTIONAL 00 e weenie 27 STEP 10 CHOOSE OPERATING SYSTEM AND VALUE ADDED SOFTWARE 29 STEP 11 CHOOSE OPERATING SYSTEM MEDIA KIT 0 2 0 cee eee eee ee eee 32 STEP 12 CHOOSE SERVICE and SUPPORT LEVEL 0 eee eee ee ee ee 33 ORDER OPTIONAL KVM LOCAL I O CABLE
52. tem listed is no longer in service and has been destroyed Sophisticated data recovery techniques have made classified proprietary and confidential information vulnerable even on malfunctioning disk drives The UCDR service enables you to retain your drives and ensures that the sensitive data on those drives is not compromised which reduces the risk of any potential liabilities This service also enables you to comply with regulatory local and federal requirements If your company has a need to control confidential classified sensitive or proprietary data you might want to consider one of the Drive Retention Services listed in Table 20 Q NOTE Cisco does not offer a certified drive destruction service as part of this service 36 Cisco UCS B200 M4 Blade Server CONFIGURING the SERVER Table 20 Drive Retention Service Options Service Service Service Description Program Name Level GSP Service Level Product ID PID UCS Support UC SUPP DR UCSD5 8x5xNBD CON UCSD5 B200M4 Service With Drive Onsite Retention UCSD7 24x7x4 Onsite CON UCSD7 B200M4 UCS Warranty Plus UC PLUS DR UCWD5 8x5xNBD CON UCWD5 B200M4 With Drive Onsite Retention UCWD7 24x7x4 Onsite CON UCWD7 B200M4 For more service and support information see the following URL http www cisco com en US services ps2961 ps10312 ps10321 Cisco UC Warranty _Support_DS pdf For a complete listing of available services for Cisco Unified Computing System see this URL
53. tp www cisco com c en us td docs unified_computing ucs hw blade servers B200M4 html O NOTE When you purchase a spare CPU the CPU cleaning kit is included S amp S Cisco UCS B200 M4 Blade Server 47 SUPPLEMENTAL MATERIAL Network Connectivity This section explains how the UCS B200 M4 server connects to Fabric Interconnects Fls using the network adapters in the UCS B200 M4 blade server and the Fabric Extender modules in the UCS 5108 blade server chassis The UCS B200 M4 server plugs into the front of the UCS 5108 blade server chassis The Fabric Extender modules plug into the back of the UCS 5108 Series blade server chassis A midplane connects the UCS B200 M4 blade server to the Fabric Extenders Figure 10 shows an example configuration where 4 x 10G KR ports are routed from the VIC 1340 1240 adapter to the Fabric Extender modules and the remaining 4x 10G KR ports are routed from the mezzanine adapter to the Fabric Extender modules Note that you cannot mix VIC 13xx Series adapters with VIC 12xx Series adapters For example if you install a VIC 1340 you cannot install a VIC 1280 In this case you must install a VIC 1380 Also the VIC 13xx Series adapters are compatible with systems implementing 62xx Series Fabric Interconnects but 61xx Series Fls are not supported All Fls are supported with the VIC 12xx Series adapters 61xx 21xx Series Fls are supported on the B200 M4 but only with the VIC 12xx Series adapters Figure 10
54. untries A listing of Cisco s trademarks can be found at www cisco com go trademarks Third party trademarks mentioned are the property of their respective owners The use of the word partner does not imply a partnership relationship between Cisco and any other company 1005R 62 Cisco UCS B200 M4 Blade Server
55. vice controlled by CPU 2 Figure 24 Option 2 VIC 1240 to UCS 2104XP Fabric Extender Cisco Storage Accelerator Port Group A Port Group B Cisco Storage Accelerator VIC 1240 Adapter Mezzanine Slot mLOM Slot PCle x16 QPI Link Cisco UCS B200 M4 Blade Server 61 TECHNICAL SPECIFICATIONS TECHNICAL SPECIFICATIONS Dimensions and Weight Table 27 UCS B200 M4 Dimensions and Weight Parameter Value Height 1 95 in 50 mm Width 8 00 in 203 mm Depth 24 4 in 620 mm Weight m Base server weight no HDDs no CPUs no DIMMs no mezzanine adapters or memory 9 51 lbs 4 31 kg m Minimally configured server no HDDs 1 CPU 8 DIMMs VIC 1340 1240 but no mezzanine adapter 11 29 lbs 5 12 kg m Fully configured server 2 HDDs 2 CPUs 24 DIMMs VIC 1340 1240 and mezzanine adapter both populated 15 98 lbs 7 25 kg Power Specifications For configuration specific power specifications use the Cisco UCS Power Calculator at http ucspowercalc cisco com Apafi Americas Headquarters Asia Pacific Headquarters Europe Headquarters Cisco Systems Inc Cisco Systems USA Pte Ltd Cisco Systems International BV Amsterdam San Jose CA Singapore The Netherlands Cisco has more than 200 offices worldwide Addresses phone numbers and fax numbers are listed on the Cisco Website at www cisco com go offices Cisco and the Cisco Logo are trademarks of Cisco Systems Inc and or its affiliates in the U S and other co
56. zanine adapter that is plugged into the mezzanine slot on the system board The maximum number of ports is four The VIC 1340 1240 senses the type of adapter plugged into the mezzanine slot In the event a Port Expander Card for VIC occupies the mezzanine slot the four 10G KR ports between the adapters are used for port expansion otherwise they are unused 50 Cisco UCS B200 M4 Blade Server SUPPLEMENTAL MATERIAL Mezzanine Adapters There are multiple options for the mezzanine slot m O based PCle adapters such as network adapters or m Cisco Storage Accelerator adapters such as Fusion io cards ey Specific examples of mezzanine adapters are NOTE In a B200 M4 configured with 1 or 2 CPUs a UCS B200 M4 blade server must have a VIC 1340 1240 installed to provide I O connectivity m Cisco adapters VIC 1380 1280 Port Expander Card for VIC m Cisco Storage Accelerator adapters Cisco UCS 785 GB MLC Fusion io ioDrive2 Cisco UCS 1300 GB Fusion ioMemory3 PX Performance line Cisco UCS 1600 GB Fusion ioMemory3 SX Scale line The following sections explain the various I O options that are possible with the different Fabric Extenders Cisco UCS 2208XP 2204XP and 2104XP and the VIC 1340 1240 and mezzanine adapters Cisco UCS B200 M4 Blade Server 51 SUPPLEMENTAL MATERIAL B200 M4 Configured with 1 CPU In a B200 M4 configured with 1 CPU the mezzanine card slot is not under the control of a CP
Download Pdf Manuals
Related Search
Related Contents
V.Smile V-Motion: Wall.E SMP - Manual de usuario Sämonitor minidrill - wtk 110-1008F spanish - Electric Bargain Store MANUAL DE INSTRUCCIONES Série FX-300 Sony BM-87DST MP3 Player User Manual View/Open - IUP DSpace Home - Indiana University of Pennsylvania Telenetics MOT202TRM Network Card User Manual MHC-RX33 Copyright © All rights reserved.