Home
Tripp Lite SmartOnline 200-240V 16kVA 14.4kW On-Line Double-Conversion UPS, N+1, Extended Run, SNMP, Webcard, 12U Rack/Tower, USB, DB9 Serial, C19 Outlets
Contents
1. in both N 1 and combined with Bypass switch operating modes Enhanced availability fault tolerance and simple hot swap replacement options make this UPS e 4 post rackmount installation rails ideal for advanced networking applications in data centers computer rooms network closets and rugged e PowerAlert software and cabling industrial locations Features e Tripp Lite SU16KRTG 16kVA 16 000VA 14 400 watt on line double conversion UPS system in 12U total rack tower configuration e Unique configuration offers 16kVA non redundant operation and automatic N 1 redundancy at load levels of 8KVA and under e Included Parallel PDU with manual bypass switch enables hot swap replacement power modules at any supported load level e Hardwire input 8 C19 outlets e Maintains full time sine wave output within 2 of selectable 200 208 220 230 240V nominal e Supports 50 60Hz operation for worldwide frequency compatibility e Expandable runtime with optional external battery packs e Some external battery configurations require the use of Tripp Lite s External Battery Configuration Software see manual e Battery independent restart e Highly efficient economy mode option e Optional SNMPWEBCARD RELAYIOCARD and RELAYIOMINI interface modules available RELAYIOMINI requires removal of USB interface module e Applications utilizing the optional network communications card require two SNMPWEBCARD accessories install one per included power module 1 6 Trip
2. tripplite com CERTIFICATIONS WPS Cenmcaions Tested to UL1778 USA Tested to CSA Canada CE Meets FCC Part 15 Category A EMI ROHS Restriction of Hazardous Substances UPS Certification Details IEC 61000 4 5 1995 B Surge Immunity WARRANTY Product Warranty Period Worldwide 2 year limited warranty 2015 Tripp Lite All rights reserved All trademarks are the sole property of their respective owners Tripp Lite has a policy of continuous improvement Specifications are subject to change without notice Photos may differ slightly from final products 6 6
3. 3UPM UPS Power modules and 2 BP240V10RT3U Battery packs Listed weights and UPS Dimensions Details dimensions for UPS Power module and Included battery pack each refer to a single unit Included Battery Pack Dimensions Bay 47 5 x25 hwd in Included Battery Pack Dimensions 133x445x635 hwd cm Included Battery Pack Weight Ibs 158 7 UPS Shipping Dimensions hwd in 36 x 40 25 x 51 UPS Shipping Dimensions hwd 91 4 x 102 2 x 129 5 cm EN a ENVIRONMENTAL Tripp Lite ieee YY 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com Operating Temperature Range 32 to 104 degrees Fahrenheit 0 to 40 degrees Celsius Storage Temperature Range 5 to 122 degrees Fahrenheit 15 to 50 degrees Celsius Relative Humidity 0 to 95 non condensing AC Mode BTU Hr Full Load 5456 AC Economy Mode BTU Hr Full Load 2046 AC Mode Efficiency Rating 100 o Load ave AC Economy Mode Efficiency Rating 96 100 Load Operating Elevation ft 0 3000m 0 to 10 000 ft Audible Noise 60 dBA at front side 1 meter Operating Elevation m 0 3000 m COMMUNICATIONS Communications Interface USB HID enabled DB9 Serial EPO emergency power off Slot for SNMP Web interface Applications utilizing the optional network communications card require two SNMPWEBCARD accessories install Network Monitoring Port Description one per included power module Additional contact closure s
4. Tripp Lite 1111 W 35th Street J Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com SmartOnline 200 240V 16kVA 14 4kW On Line Highlights Double Conversion UPS N 1 Extended Run o re pean SNMP Webcard 12U Rack Tower USB DB9 Serial ie eset ae ay rege 0 9 power factor C19 Outlets 200 208 220 230 240V 50 60Hz MODEL NUMBER SU16KRTG output 96 Efficient Economy mode option e Hot swap power amp battery modules N 1 fault tolerance at loads up to 8kVA e USB RS232 EPO ports Support for SNMP WEB amp other card options e Front panel LEDs with detailed LCD monitoring and control screen e Expandable runtime with optional external battery packs e Hardwire input 3 wire C19 outlets Description Tripp Lite SU16KRTG 16 000VA 16kVA 14 400 watt online double conversion UPS system offers complete power protection for critical server network and telecommunications equipment in a 12U rack tower Package Includes e Two SU8000RT3UPM UPS power modules e Two BP240V10RT3U battery packs service interruptions during UPS overload or internal fault conditions Included parallel PDU with manual bypass SUPDMB20KIEC Parallel PDU configuration This system delivers complete N 1 redundancy when used at loads up to 8kVA and non redundant operation at loads between 8 and 16kVA Fault tolerant auto bypass prevents unexpected switching enables hot swappable replacement of all major UPS system components
5. ncy matches input nominal on startup Frequency conversion mode enables conversion of 60Hz to Frequency Compatibility Details 50Hz or 50Hz to 60Hz no de rating Output Voltage Regulation Line 2 Mode i Output Voltage Regulation Sano Economy Line Mode SRU Output Voltage Regulation Battery 2 Mode i Output Receptacles 8 C19 Output Circuit Breakers 8 20A breakers protect one C19 outlet each Output AC Waveform AC Mode Pure Sine wave 2 6 Tripp Lite ERRON 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com INPUT Voltage Compatibility VAC 200 208 230 240 220 Input Phase Single Phase BATTERY Expandable Runtime Description For best results add external batteries in multiples of two so that both included 8kVA power modules have an equal number and type of connected battery packs Battery Recharge Rate Included Batteries Battery Replacement Description Hot swappable user replaceable external battery packs VOLTAGE REGULATION Voltage Regulation Description 2 output voltage regulation in standard online double conversion mode Overvoltage Correction Corrects overvoltages up to 300V Undervoltage Correction Corrects undervoltages as low as 100V USER INTERFACE ALERTS amp CONTROLS Less than 6 hours from 10 to 90 typical full load discharge Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options Fron
6. p Lite 1111 W 35th Street amp Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com e HID compliant USB interface e Includes Free PowerAlert monitoring software PowerAlert LOCAL PowerAlert NSA and PowerAlert NMS for monitoring up to 250 SNMP enabled UPS PDU and other networking devices e Optional 2POSTRMKITHD supports installation in 2 post 19 inch racks 4 required e Optional 2 9USTAND supports upright tower placement 2 required e Supports Emergency Power Off EPO via built in interface e Front panel LEDs and LCD readout with scroll controls e LED LCD display panel rotates for viewing in rackmount or tower configurations e External battery packs are field replaceable and hot swappable e Frequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz no de rating Specifications General Info OUTPUT Supports up to 105 load continuously in double conversion mode 106 to 125 for 1 minute 126 to 150 for 30 Output Capacity Details seconds Loads over 150 trigger immediate bypass mode operation to support loads directly from mains power Double conversion mode is automatically restored as load levels are reduced to 95 or less poorer 8S Nominal Output Voltage s 200V 208V 220V 230V 240V Supported i i i Nominal Voltage Details Voltage selection via front panel LCD interface Frequency Compatibility 50 60 Hz Supports 50 to 60 Hz and 60 to 50 Hz conversion a Output freque
7. t Panel LCD Display LED LCD panel rotates for viewing in rack tower formats LCD Display supports ENGLISH FRENCH GERMAN ITALIAN SPANISH and PORTUGUESE see manual 2 Switches control off on power status and alarm cancel self test operation 2 additional switches support set and Switches execute scrolling LCD functions bundled PDU includes bypass switch to enable hot swap UPS power module replacement Alarm Cancel Operation Alarm cancel switch Audible Alarm Unique audible alarms for all major UPS environmental and power conditions see manual 6 LEDs indicate line power online mode economy bypass mode on battery charger and AC output status LCD LED Indicators ne screen offers additional information and control options 3 6 Tripp Lite ieee YY 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www tripplite com SURGE NOISE SUPPRESSION Time PHYSICAL sien aa AEPESRONY 4 sets of adjustable 4 post rack rails included one for each included 3U module Installation Form Factors Supported 2 post rackmount POSTRMKITHD Tower 2 9USTAND with Optional Accessories Optional Mounting Accessory Notes Qty 4 2POSTRMKITHD required Qty 2 2 9USTAND required UPS Power Module Dimensions 5 14 x 17 5 x 25 82 hwd in UPS Power Module Dimensions 13 1 x 44 5 x 65 6 hwd cm Installed Whole System Maximum 325 Rack Depth in Installed Whole System Maximum 82 6 Rack Depth cm Includes 2 SU8000RT
8. upport with optional RELAYIOCARD and RELAYIOMINI interface cards RELAYIOMINI installation requires removal of panel containing USB ports PowerAlert Software Included Communications Cable USB DB9 serial and EPO cables included WatchDog Compatibility Supports Watchdog application OS and hard reboot restart options for remote applications LINE BATTERY TRANSFER No transfer time 0 ms in online double conversion mode Transfer Time Economy Mode 8 milliseconds typical power failure response in optional economy mode Low Voltage Transfer to Battery 100V Power Setpoint High Voltage Transfer to Battery 300V Power Setpoint SPECIAL FEATURES Cold Start Startup in Battery Mode g During a Power Failure Cold start operation supported Optional economy mode enables high efficiency bypass operation with a maximum output voltage variation of Economy Mode Operation 10 Double conversion mode is automatically restored as mains voltage varies beyond 10 with less than 1 millisecond transfer time between modes High Availability UPS Features Automatic inverter bypass Manual bypass switch Detachable hot swap PDU Hot swappable UPS power module Hot swappable batteries High efficiency economy mode operation Support for daily startup and shutoff Schedulable daily hours of economy mode operation Green Energy Saving Features 5 6 Tripp Lite 1111 W 35th Street Chicago IL 60609 USA Telephone 773 869 1234 www