Home
AEG Protect D. 1000 BP
Contents
1. Warranty UPS amp Battery A real time event logger ensures careful observation and analysis of events as they occur In addition a regular automated battery test can be planned Main characteristics VFI topology online double conversion protects against all network problems An increase of the available performance by approx 20 through a 0 9lag power factor Increased efficiency through the ECO and ECO mode Advanced battery charging technology for maximum durability of the battery Hot swappable batteries easy replacement through hinged front Additional battery packs for easy scaling of the autonomy times Extension slot for communication cards communication in parallel is possible through the RS232 USB interface and SNMP Low height 2 U including integrated batteries Switchable UPS outputs with innovative locking mechanism Display of the UPS parameters on a graphic LCD direct configuration is possible with the control panel Freely programmable potential free contact plus emergency shutdown contact May also be used as a frequency converter 36 month warranty with replacement service in advance free registration required AEG POWER SOLUTIONS Classification VFI SS 211 acc to IEC 62040 3 D 1000 D 1500 D 2000 D 3000 Power type rating 1000 VA 1500 VA 2000 VA 3000 VA 900 W 1350 W 1800 W 2700 W Ree ude d integrated batten
2. PROTECT D SINGLE PHASE IN OUT UPS SYSTEM Uninterruptible Power Supply 1 Phase Input 1 Phase Output 1000 10000 VA power supply with integrated batteries Efficient high performance UPS for rack use With a high power factor of 0 9lag the Protect D series exceeds the power of conventional UPS systems by 20 Efficiency is significantly increased during normal operation as well as in the energy efficient ECO and ECO operating modes Compact and flexible The height of the UPS electronics and battery together is only 2 U With the flap front cover battery replacement is very easy The autonomy times can be increased with additional battery packs connected battery packs are automatically detected All batteries can be replaced during operation hot swappable Our advanced battery charging technology allows for short charging times and battery preserving charging characteristics at the same time Many interfaces RS232 USB Slot EPO as well as a potential free contact within the series ensure an outstanding commu nication capacity Secure and easy to use An innovative locking mechanism at the UPS outputs prevents accidental separation of the loads The multilingual graphic screen is very easy to read even from a longer distance thanks to its large format Together with three LEDs at the top it displays the essential operating conditions The UPS can be directly administered with the control panel 36 Months
3. 60 Hz 10 Mains current system reaction 20 99 THD lt 5 Current consumption at nominal load max DS IN ATA UPS OUTPUT Rated output voltage adjustable 200 V AC 208 V AC 220 V AC 230 V AC default 240 V AC 1 Frequency in battery frequency converter mode 50 Hz 60 Hz 0 5 Output current at 230 V AC 26A ASA A Transfer time at mains outage O ms without interruption Voltage waveform Sinusoidal distortion THD lt 2 Overload response double conversion mode lt 130 for 2 min 130 150 for 30 s then automatically switches over to electronic bypass 0 ms Crest factor 3 1 Short circuit response Short circuit proof 3 x I for 100 ms BATTERY Type Sealed maintenance free proprietary brand integrated hot swappable Rated voltage linked 180 V DC 240 V DC Battery management Temperature compensated with discharge protection automatic battery test programmable and battery pack detection Charging time to 90 rated capacity 3h COMMUNICATION Interfaces dual monitoring RS232 USB communication slot can be used parallel with RS232 USB input contact for emergency shutdown programmable potential free contact Shutdown software on CD 5 network licenses for all common OS e g Windows Linux Mac Unix Sun etc Failure indicators acoustic visual 3 LED s with traffic light display detailed indication via LCD display alarms at mains failure overload battery charging battery repl
4. ke 23 kg 28 kg 41 kg 41 kg Mains input cord 1 x EU 1 x UK UPS management software CompuWatch CD communications cables RS232 amp USB operating instructions rack rails device cables 3 x IEC 320 C13 D 1000 D 2000 3 x IEC 320 C13 1 x IEC 320 C19 D 3000 CE PROTECT D 6000 10000 36 Months Warranty UPS amp Battery Top performance in rack format Protect D 6000 and D 10000 compliment the range of the successful Protect D series With Protect D 10000 a power level of 10 kVA in rack design is available for the first time Protect D 6000 and Protect D 10000 have the same advantages and characteristics as the smaller models including the high power factor of 0 9lag Compact housing dimensions Thanks to their compact design the devices can also be used in IT cabinets with a depth of only 800 mm Protect D 6000 including battery connection unit and manual bypass unit fits within 3 standard height units The 10 kVA version with a complete battery system connection unit and integrated manual maintenance bypass fits within 5 standard height units The sophisticated design with removable connection unit and battery systems with plug in technology make the assembly in the rack and the electrical installation as easy as possible The weight is unimportant as the batteries can be mounted at the end of the installation Flexible and maintenance friendly Th
5. acement fan fault data logger with clear text display incl date and time history GENERAL DATA Efficiency ECO mode gt 96 gt 97 Efficiency at nominal load double conversion mode gt 92 gt 93 Audible noise 1 m distance lt 55 dB A Operating temperature range 0 40 C Humidity 0 95 without condensation Operation altitude Up to 1000 m at nominal load EMC conformity EN 62010 2 Class C2 Product safety EN 62040 1 AC input Permanent connection via terminals separate power option from rectifier and bypass connector unit with removable integrated manual bypass for installation or subsequent maintenance of UPS with optional cable entry from top or rear Number of outputs automatically locked 1 x fixed connection on terminal block plus 1 x fixed connection on terminal block plus 2 NEC 32016 lS IPaIEC 2201 19 x EC 320 C19 Housing Metal casing blackline with aluminum cabinet front Dimensions approx W x H x D mm AB O19 x lszioU x 715 ADG GO x220 65 U x 715 without front panel depth with front panel plus 35 mm depth with front panel plus 35 mm Teen 4626 19 x 132BUX595 Weight approx without batteries 20 kg 325 ke Weight approx with batteries 46 kg 82 5 kg Weight approx battery extension unit 44 5 kg 63 kg Shipment Rack rails kit 16 A IEC device cable UPS management software CompuWatch CD incl 5 network licenses RS232 and USB cable operating instructions Conformity GE AEG Power Solutions Approach
6. e equipment offers separate feed for the rectifiers and bypass Protect D 6000 and 10000 can also be operated with only one feed Both options are provided to deliver highest flexibility and security To increase power or to be able to serve the demand for active redundancy Protect D 6000 and Protect D 10000 are prepared for parallel operation In order to ease maintenance work a manual bypass is already integrated into the removable connection unit Special characteristics Suitable for IT cabinets with a depth of 800 mm High power density in a compact housing Very easy assembly through removable connection unit and batteries with plug in technology Dual or single input Prepared for paral lel operation Integrated manual maintenance bypass foolproof operation 36 month warranty with replacement service in advance free registration required Classification VFI SS 111 acc to IEC 62040 3 D 6000 D 10000 Power type rating Ready for redundant or 6000 VA 10000 VA increased performance parallel operation 5400 W 9000 W Part number UPS incl internal battery system 600 000 8439 600 000 8440 Part number additional battery pack 600 001 1042 600 001 1044 UPS INPUT Input voltage 220 V AC 230 V AC 240 V AC Voltage range without battery mode 176 V AC 120 V AC to 50 utilization 276 V AC Voltage range bypass input 184 264 V AC Frequency auto selection 50 Hz
7. rammable and battery pack detection 3h RS232 USB communication slot can be used parallel with RS232 USB input contact for emergency shutdown programmable potential free contact 5 network licenses for all common OS e g Windows Linux Mac Unix Sun etc 3 LED s with traffic light display detailed indication via LCD display alarms at mains failure overload battery charging battery replacement fan fault data logger with clear text display incl date and time history GENERAL DATA Efficiency ECO mode Efficiency at nominal load double conversion mode Audible noise 1 m distance Operating temperature range Humidity Operation altitude EMC conformity Product safety Number of outputs switchable automatically locked Housing Dimensions approx W x H x D mm UPS Dimensions approx W x H x D mm battery Weight approx UPS incl integrated battery Weight approx battery extension unit Shipment Conformity gt 95 gt 98 gt 88 gt 88 gt 89 gt 90 lt 44 dB A lt 45 dB A lt 52 dB A 0 40 C 0 95 without condensation Up to 3000 m at nominal load EN 62040 2 Class C1 EN 61000 3 2 EN 61000 3 3 EN 62040 1 eK ECRZOCILIZA OxIEC S20IC 13 272 Gx IEC 320C13 673 7 IPalE 220619 Blackline metal case with aluminum front 482 6 19 x 88 2 U x 430 482 6 19 x 88 2 U x 600 482 6 19 x 88 2 U x 430 482 6 19 x 88 2 U x 430 16 kg 19 5 kg 19 kg 295
8. reysien 600 000 8434 600 000 8436 600 000 8437 600 000 8438 Part number additional battery pack 600 000 8441 600 000 8442 600 000 8443 UPS INPUT Input voltage 220 V AC 230 V AC 240 V AC Voltage range without battery mode 120 276 V AC 140 276 V AC load dependent Frequency auto selection Mains current system reaction Current consumption at nominal load max 50 Hz 60 Hz 5 Hz gt 0 99 THDi lt 8 4 8 A L2 A 9 6 A IBYEN UPS OUTPUT Rated output voltage adjustable Frequency in battery frequency converter mode Output current at 230 V AC Transfer time at mains outage Voltage waveform Overload response double conversion mode Overload response battery mode Crest factor Short circuit response BATTERY 200 V AC 208 V AC 220 V AC 230 V AC default 240 V AC 2 50 Hz 60 Hz 0 25 Hz 43 A 6 5A 8 7A 13A O ms without interruption Sinusoidal distortion THD lt 3 lt 130 for 5 min 130 150 for 15s lt 130 for 12 s 130 150 for 2s a Short circuit proof 4 x for 100 ms Type Rated voltage linked Battery management Charging time to 90 rated capacity COMMUNICATION Interfaces dual monitoring Shutdown software on CD Failure indicators acoustic visual Sealed maintenance free proprietary brand integrated hot swappable SONDE 48 V DC 12V DC Temperature compensated with discharge protection automatic battery test prog
9. your local AEG Power Solutions representative for further support Contact details can be found on AE www aegps com POWER SOLUTIONS AEGPS Protect D EN Monat Jahr V1 Due to our policy of continuous development the data in this document is subject to change without notice AEG is a registered trademark used under licence from AB Electrolux
Download Pdf Manuals
Related Search
Related Contents
Chave de software PE-DESIGN Pelco C1666M-A User's Manual USER MANUAL BROADCASTING SIGNAL ANALYZER Copyright © All rights reserved.
Failed to retrieve file