Home

Chief LCM1UP flat panel ceiling mount

image

Contents

1. id oQ HH x 2 Figure 8 Adjustments CAUTION Watch for pinch points Do not place fingers between moveable parts IMPORTANT Always use two hands one at bottom of display and one at top of display to adjust ceiling mount Roll The ceiling mounts allow up to 3 roll each direction 1 Turn the roll adjustment screw in the direction necessary for the desired roll See Figure 9 2 Stop adjusting when the desired setting is reached FF Figure 7 3 Raise the latch mechanism on both interface brackets to lock bracket in place See Figure 7 4 Fasten bracket against ceiling mount extrusion using one 10 24 x 5 8 button head cap screw HH See Figure 8 5 Repeat for other interface bracket Roll adjustment screw Figure 9 Installation Instructions LCM1UP Tilt OPTIONAL Security The ceiling mounts allow 5 to 20 tilt The ceiling mount can 1 OPTIONAL Add padlock not included to each interface be locked at 0 5 10 and 15 tilt bracket to lock display to ceiling mount See Figure 12 3 Loosen two tilt friction screws located each side See Figure 10 4 Adjust tilt as required Note specific degrees of tilt See Figure 10 5 Tighten two tilt adjustment screws if NOT using the 0 5 10 or 15 settings
2. Padlock Optional Ceiling mount not shown for clarity Figure 12 friction Installing Covers 1 Install four interface bracket covers GG over the top and bottom of both interface brackets See Figure 13 NOTE Be sure to line up tabs inside the bracket covers with holes on sides of interface brackets See Figure 13 Figure 10 6 If using the tilt settings of 0 5 10 or 15 insert two 10 24 x 1 2 Phillips head screws Y and two 10 24 lock nuts Z to lock mount at the specific tilt See Figure 11 Example shows locking tilt at 15 Figure 11 Figure 13 LCM1UP Installation Instructions 2 Install back cover DD into four holes on back of ceiling mount See Figure 14 Figure 14 3 Install one side cover EE onto side of ceiling mount using two 10 24 x 1 2 flat head screws W See Figure 15 4 Repeat for other side of ceiling mount Figure 15 10 Installation Instructions LCM1UP 11 LCM1UP Installation Instructions CHIEF Our Mounts Your Vision Chief Manufacturing a products division of Milestone AV Technologies 8800 002403 Rev00 2013 Milestone AV Technologies a Duchossois Group Company www chiefmfg com 08 13 USA International Europe Asia Pacific D mu
3. Attaching Interface Brackets to Display 1 Lower the latch mechanism on each interface bracket FF See Figure 5 o Center of A K bracket S AK Figure 6 WARNING IMPROPER INSTALLATION CAN LEAD TO DISPLAY FALLING CAUSING SERIOUS PERSONAL INJURY OR DAMAGE TO EQUIPMENT Using screws of improper size may damage your display Properly sized screws will easily and completely thread into display mounting holes If spacers are required be sure to use longer screws of the same diameter mechanism 3 Select correct screws spacers if necessary and universal washers from the hardware bag A N and attach brackets FF to back of screen See Figure 6 Figure 5 2 Align the center of the interface bracket FF with center of screen See Figure 6 NOTE The diamond shape hole in the bracket corresponds to the center of the mount LCM1UP Installation Instructions Attaching Display to Ceiling Mount 1 Ensure that the latch mechanisms on interface brackets Ceiling mount not shown for clarity FF are already lowered See Figure 5 2 While supporting both sides of display lower display onto ceiling mount hooking top of interface brackets onto front of ceiling mount See Figure 7 WARNING IMPROPER INSTALLATION CAN LEAD TO DISPLAY FALLING CAUSING SERIOUS PERSONAL INJURY OR DAMAGE TO EQUIPMENT The display MUST be centered on the ceiling mount
4. mou no 6436 City West Parkway Eden Prairie MN 55344 800 582 6480 952 225 6000 877 894 6918 952 894 6918 Franklinstraat 14 6003 DK Weert Netherlands 31 0 495 580 852 31 0 495 580 845 Office No 1 on 12 F Shatin Galleria 18 24 Shan Mei Street Fotan Shatin Hong Kong 852 2145 4099 852 2145 4477
5. understand and follow all instructions can result in serious personal injury damage to equipment or voiding of factory warranty It is the installer s responsibility to make sure all components are properly assembled and installed using the instructions provided WARNING Failure to provide adequate structural strength for this component can result in serious personal injury or damage to equipment It is the installer s responsibility to make sure the structure to which this component is attached can support five times the combined weight of all equipment Reinforce the structure as required before installing the component WARNING Exceeding the weight capacity can result in serious personal injury or damage to equipment It is the installer s responsibility to make sure the combined weight of all components located between the mount up to and including the display does not exceed 125 Ibs 56 7 kg WARNING Use this mounting system only for its intended use as described in these instructions Do not use attachments not recommended by the manufacturer WARNING Never operate this mounting system if it is damaged Return the mounting system to a service center for examination and repair WARNING Do not use this product outdoors NOTE The LCM1UP mounts are designed to be mounted to a 1 1 2 NPT or NPSM following ANSI ASME B1 20 1 Schedule 40 0 154 minimum thickness steel or aluminum ASTM B221 threaded extension column not i
6. 32 M4x16mm M4x20mm M4x25mm M5xi6mm See Gg Age cr B G 6 H 6 M5x25mm M6x16mm M6x25mm T 1 U 2 V 2 i 10 24 x 1 4 5 16 x 1 5 16 e e l e tare J 6 uon l W 5 16 ala l I 4 Q N 8 a Z 2 UNS en 8S Ch OLG vm ehe 9p 750x 323x 250 750x 344x 500 Washer wn 1088212 labeled N CI Nein Gerent ES E AA 1 HH 2 10 24 x 5 8 Bottom stop collar Used with CPA Series extension column system BB 1 Bottom coupling Used with 1 1 2 NPT column system N DD 1 Back cover EE 2 Side cover LCM1UP Installation Instructions INSTALLATION WARNING FAILURE TO PROVIDE ADEQUATE STRUCTURAL STRENGTH FOR THIS COMPONENT CAN RESULT IN SERIOUS PERSONAL INJURY OR DAMAGE TO EQUIPMENT It is the installer s responsibility to make sure the structure to which this component is attached can support five times the combined weight of all equipment Reinforce the structure as required before installing the component IMPORTANT These instructions assume that a 1 1 2 NPT or NPSM following ANSI ASME B1 20 1 Schedule 40 0 154 minimum thickness steel or aluminum ASTM B221 threaded extension column with a minimum of four threads engaged not included or a UL Listed Chief CPA Series extension column not included has been properly installed and is in place NOTE Proceed to Attaching Mount to NPT Column section or Attaching Mount to CPA Extension Colu
7. INSTALLATION INSTRUCTIONS LCM1UP Shown installed to CPA Series extension column U as example only Single Portrait Flat Panel Ceiling Mounts Our Mounts Your Vision A CHIEF LCM1UP LCM1UP Installation Instructions DISCLAIMER Milestone AV Technologies and its affiliated corporations and subsidiaries collectively Milestone intend to make this manual accurate and complete However Milestone makes no claim that the information contained herein covers all details conditions or variations nor does it provide for every possible contingency in connection with the installation or use of this product The information contained in this document is subject to change without notice or obligation of any kind Milestone makes no representation of warranty expressed or implied regarding the information contained herein Milestone assumes no responsibility for accuracy completeness or sufficiency of the information contained in this document Chief is a registered trademark of Milestone AV Technologies All rights reserved A IMPORTANT SAFETY INSTRUCTIONS WARNING A WARNING alerts you to the possibility of serious injury or death if you do not follow the instructions CAUTION A CAUTION alerts you to the possibility of damage or destruction of equipment if you do not follow the corresponding instructions WARNING Failure to read thoroughly
8. ador Allentare il fissaggio Bevestiging losdraaien Desserrez les fixations Remove Quitar Entfernen Remover Rimuovere Verwijderen Retirez Phillips Screwdriver Destornillador Phillips Kreuzschlitzschraubendreher Chave de fendas Phillips Cacciavite a stella Kruiskopschroevendraaier Tournevis pointe cruciforme Optional Opcional Optional Opcional Opzionale Optie En option Open Ended Wrench Llave de boca Gi Gi Gabelschl ssel Chave de bocas Chiave a punte aperte Steeksleutel Cl fourche C d y 4 3 Hex Head Wrench Llave de cabeza hexagonal Sechskantschl ssel Chave de cabega sextavada Chiave esagonale Zeskantsleutel Cl t te hexagonale By Hand A mano Von Hand Com a m o A mano Met de hand la main Installation Instructions LCM1UP TOOLS REQUIRED FOR INSTALLATION a eeeeeeeocoooooococoe 2000000008 000 DES e FF 2 Interface bracket GG 4 Interface bracket cover Ceiling cum N 3 32 included 1 8 included 2 5 32 included M5 included 1 2 or 13mm PARTS A v Interface Bracket Hardware Kit i Se amp om R 1 S 1 A 8 B 6 C 6 D 6 3 32 1 8 5
9. mn section as appropriate Attaching Mount to NPT Column CAUTION WATCH FOR PINCH POINTS Do not place fingers between moveable parts 1 Slide ceiling mount CC up from below onto installed column not included See Figure 1 2 Thread bottom coupling BB onto installed column until tight with a minimum of four threads engaged Figure 1 3 Install and tighten one 10 24 x 1 4 set screw T into bottom coupling BB See Figure 1 4 Install and tighten two 5 16 set screws X through back of mount CC and against column See Figure 2 Figure 2 Attaching Mount to CPA Extension Column CAUTION WATCH FOR PINCH POINTS Do not place fingers between moveable parts 1 Slide ceiling mount CC up from below onto installed column not included See Figure 3 2 Slide bottom stop collar AA onto installed column lining up holes in collar with holes in column Figure 3 3 Install two 5 16 x 1 self tapping screws U through two 5 16 flat washers V bottom stop collar AA and into installed column 4 Install and tighten 5 16 x 3 4 set screw X into bottom stop collar AA See Figure 3 Installation Instructions LCM1UP 5 Install and tighten two 5 16 x 3 4 set screws X through back of mount CC and against column See Figure 4 E 9 UV x x2 Figure 4
10. ncluded OR a UL Listed Chief CPA Series extension column not included NOTE The LCM1UP mounts are intended to be used with the UL Listed CPA Ceiling Plates not included CPA330 CPA365 CPA395 The following UL Listed Chief ceiling plates WITHOUT swaged collars not included may also be used CMA330 CMA345 CMA395 SAVE THESE INSTRUCTIONS Installation Instructions LCM1UP 5 40 4 25 108 0 C L OF COLUMN 6 37 1617 T oam 12 7 0 50 nee i 12 8 i 3 SIT o o El 8 8 8 8 20 84 8 529 4 3 o o 8 o o E 20 00 3 8 508 0 8 o o 8 9 32 50 E E 825 5 3 i 8L o o i o i 31 50 800 0 aal SS a 144 sp I SES TILT RANGE 136 5 LI E ROLL ADJUST POSTYE IU I AT 5 TO 20 PADLOCK HOLE U 0 34 L I 8 6 1 i ls 15 75 M 400 0 DIMENSIONS INCHES MILLIMETERS LCM1UP Installation Instructions LEGEND Tighten Fastener Apretar elemento de fijaci n Befestigungsteil festziehen Apertar fixador Serrare il fissaggio Bevestiging vastdraaien Serrez les fixations Adjust Ajustar Einstellen Ajustar Regolare Afstellen Ajuster Loosen Fastener Aflojar elemento de fijaci n Befestigungsteil l sen Desapertar fix