Home
Irox METE-ON 7
Contents
1. IROX Personal Meteo Centre with Wireless Thermo Hygrometer Mete On 7 l D7 METEOTIME MUST READ BEFORE GETTING STARTED Your Meteotime Weather Station is different to traditional weather stations which measure the prevailing conditions only the data of this weather station is based on the METEOTIME which is worked out on a daily basis by highly professional meteorologists using state of art instruments The Meteotime Weather Station is engineered in such a way that it is able to receive the coded METEOTIME signal containing the weather information The information is broadcasted via the stations for radio controlled clocks HBG located in Switzerland and DCF77 located in Germany For this reason your Meteotime Weather Station is also a radio controlled clock with all the known advantages such as always showing the exact time and automatic change to daylight saving time in winter and in summer You are able to receive weather forecasts for 60 meteorological regions within Europe for up to 4 days in advance and offer a 2 day advance forecasts for an additional 30 regions WHAT DOES IT TAKE TO GET GOOD RECEPTION Please read the brochure Personal Meteo Centre PMC Important Watch the symbol GOOD RECEPTION or BAD RECEPTION on the display Once you have found the right location for GOOD RECEPTION you may leave the Meteotime Weather Station there it will collect its data by radio controlled signal Within a fe
2. amp Sunset Time Time amp Date 10 SWITCH DAY WEATHER INFORMATION lt gt NIGHT WEATHER INFORMATION The device is able to base on the SUNRISE time and SUNSET time to automatically switch to DAY WEATHER and NIGHT WEATHER respectively The unit is preset to show DAY WEATHER after sunrise time and NIGHT WEATHER after SUNSET time The user can press the WEATHER button to see the DAY Weather for 10 second period if currently show the NIGHT WEATHER or vice verse WEATHER CRITICAL WEATHER INFORMATION Meteotime Weather signal contains the Critical Weather Information such as Gust Frozen Rain Heavy Snow Thunder Strong UV Dense Fog Bise Mistral etc for today and coming three days A critical weather alert signal will be turned on in case that day has critical weather that the user must know Sometimes there are more than one critical weather information in the 4 days Press WEATHER key to read the critical weather information one by one The special icon of the day will be flashed when you read the Information DAY lt gt NIGHT lt i s ee s Te a Weather status e Press SET key to go back to the display of CITY lt SUNRISE amp SUNSET TIME lt gt TIME amp DATE If you would like to read the Weather Information in the information window then press WEATHER Key to display DAY lt NIGHT Weather information and also the Critical Weather Info
3. information window ACTIVATE FAVOURITES Once you have set your city as described above you may select more cities for easy access Instead of terminating the setting with the key SET you continue as follows e If Frankfurt am Main is your selection as one of your favourite cities then press TEST v to confirm A V will be shown on top of your selected city and it will be stored into your personal memory list Now you may press A or W to select more cities in the same country and then press TEST V to confirm e If you wish to select cities from different countries you have to exit the setting with SET and re enter it again as described above in order to change the country You may select maximum FIVE cities as favourites If you want to add more cities then MEMF UL will show in the Information Window When all settings are done press SET to confrim and exit the setting mode REMARK If after inserting the batteries the first time you are skipping the city selection the product will select by default Frankfurt am Main as your selected city DISPLAY OF FAVOURITES If you have selected more than one city as favourite as an example Frankfurt am Main Paris and Stockholm then you are able to scroll through these cities by pressing A or W when the Information Window shows the CITY NAME Press SET until it oo the City Name FRANKFURTM LA gt PARTS La vi gt STOCKHOLM REMOVE A
4. CITY FROM THE LIST OF FAVOURITES e Press and Hold SET for 3 seconds cou INTR y is shown in the Information Window then press A or W to select the country e Press SET key to confirm the Country Then press A or W to go to your selected city with the J e Press TEST v to remove the vV Now this city is removed from the favourites e Repeat this if you wish to remove more cities from your list e Now you may also press A or W to select another favourite city Once you have made all your changes press SET to quit F y T will be shown in the information window After 4 seconds it will go to the City Date Time Mode PERSONALIZED A PLACE NAME Press and Hold SET for 3 second In the information window COUN ITRY is shown and then press A or W key to select the country Let s said you have selected the country Germany which is represented in J GER e Press SET key to confirm the Country let s said we select Germany right now and then the information window will show Jy e Then press A or W key to select the city and the city name will be shown in the information window such as F RANKER TM means the city Frankfurt am Main and you would like to enter a new city which is near the region of Frankfurt am Main e Press the MEM key a cursor flashes on the first position of the Information Window Then following input commands then apply KEY Function A or
5. h shows Time amp Date Sunrise amp Sunset Cities and Critical Weather Information Description Today Weather Information including Wind Speed Wind L Direction and the probability of Rain Snow Hail Day amp Night may vl gt y g WU IO gt Da Temperature Day amp Night P gt lt J Weather Status pee A E ict A 1 Lie 4 In Outdoor Temperature amp TU yy UES y H ove cr gt Tomorrow One day after and ERE 4 Two Day after Weather a ma Fie k Information including Day amp 4740 Night Temperature Day amp Night Be eta co g Weather Status kL d n Information Window J irox Main Unit FA THERMO HYGROSENSOR C METEOTIME Remote Thermo Hygrometer There are total 8 buttons on the Main Unit namely SET e Selected City lt Time Date lt gt Sunrise Sunset e Each press of SET will display the selected City Time Date or Sunrise Sunset Press and HOLD SET for 3 second to select your lt 1 gt Country lt 2 gt Time Zone lt 3 gt Language lt 4 gt Contrast of the LCD display WEATHER e Critical Weather Information lt gt Time Date lt Day Night Weather Status Change A increasing the value during setting e Chose one of the pre selected cities v e decreasing the value during setti
6. he R amp TTE Directive EN 50371 2002 Low voltage directive applied standard s EN 60950 1 2006 Additional information The product is therefore conform with the Low Voltage Directive 73 23 EC the EMC Directive 89 336 EC and R amp TTE Directive 1999 5 EC appendix II and carries the respective CE marking RTTE Compliant Countries All EU countries Switzerland CH 0 25 Aud Norway N 15
7. ng e Chose one of the pre selected cities BACKLIGHT e Turn on backlight for 8 seconds Any key pressed during backlight is ON the backlight still turned on MEM e display the maximum and minimum measured Temperature in record e Press and Hold for 3 second to clear all the Max and Min record TEST V e Find the place for the device which has a good reception Add the city into the list of your desired cities OR Remove the city out of the list of desired Cities e Edit your home town In OUT e Switch to read Indoor Thermo hygrometer lt Outdoor Thermo hygrometer e Press and Hold for 3 second to force the main unit to search for the outdoor sensor GETTING START e Insert 2 pcs AAA batteries for remote sensor and then insert 4 pcs AA batteries for the main unit The main unit will automatically scan for the radio controlled clock signal and the Meteotime Weather signal e The time and date will appear in a few minutes Since there is a large amount of Weather information for all regions and days the unit needs about 24 hours from the time of the initial setup to complete the reception of all data e After the time and the date signal is being received successfully the display shows SELECT COUNTRY and then FRANKFURT as default city in the information window To change the Country and the City please see the information below e If the unit is able to receive the Meteotime signal successfully the Meteotime icon is ap
8. oking for a better location e The test lasted for around 1 minute You can restart the test with the TEST key at any time and also discontinue the test by press the TEST key SWITCH CITY lt gt SUNRISE amp SUNSET TIME lt gt TIME amp DATE After inserting the batteries the weather station searches for the Radio controlled Time signal as well as the MeteoTime signal After it has successfully received the MeteoTime signal the display shows in the information window Select Country After a few more minutes the information windows the default city FRANKFURTM e You are able to press SET to switch from the display of the City to Sunrise amp Sunset time OR Time amp Date for Frankfurt am Main SET Ar SET FRANKFURTM lt 2 619 998 A ag mr m1 1 SELECT THE COUNTRY AND THE CITIES e Press and Hold SET for 3 seconds in the information window COUNT Y is shown and then press A or W to select the country For example If you see in the information window GER that means you have selected Germany e Press SET to confirm the Country Assuming you have selected Germany then the information window will show TY e Then press A or W to select the city and the city name will be shown in the information window Example FRANKFURT M means the city of Frankfurt am Main Press now SET to accept the setting From now on the selected city will now be shown in the
9. oo Mostly Cloudy Heat Storms Overcast Sleet Showers Stratus Clouds Fog Snow Showers Sleet Showers Snow Light Rain SPECIFICATION ON IN OUTDOOR TEMPERATURE AND HUMIDITY MEASUREMENT Temperature Display Range 40 degree C to 70 degree C Temperature Resolution 0 1 degree C Temperature Operating Range Main Unit 5 degree C to 50 degree C Temperature Operating Range Sensor Unit 20 degree C to 60 degree C Temperature Accuracy 1 degree C Humidity Display Range nH 1 to 99 Humidity Resolution 1 Humidity Accuracy 5 within 25 80 at 25 C RF Transmission Frequency 433 Mhz RF Transmission range Maximum 30 meters Open Area Main Unit is powered by AA batteries x 4 pcs Outdoor Thermo hygrometer is powered by AAA batteries x 2 pcs EC DECLARATION OF CONFORMITY Product Mete On 7 This product contains the approved transmitter and complies with the essential requirements of Article 3 of the R amp TTE 1999 5 EC Directives if used for its intended use and that the following standard s has have been applied Efficient use of radio frequency spectrum Article 3 2 of the R amp TTE Directive EN 300 220 2 V2 1 1 2006 EN 300 330 2 V1 3 1 2006 Electromagnetic compatibility Article 3 1 b of the R amp TTE Directive EN 301 489 03 V1 4 1 2002 EN 301 489 1 V1 6 1 2005 Electromagnetic compatibility Article 3 1 a of t
10. peared in the second row of display Otherwise the Meteotime will be means it successfully receives today s weather information Otherwise it will be 4 means it is able to receive the Meteotime weather signal Otherwise it will be g K 4 means it successfully receives tomorrow weather information Otherwise it will be J means it successfully receives weather gt information of one day after Otherwise it will be means it successfully receives weather gt information of two day after Otherwise it will be CZ 6 In the event the Meteotime icon change to O that means there are potential sources of interference on the unit The sources of interference may come from the electronics equipment such as TV set computers household machines etc It may also be due to lots of concrete metal parts and electrical equipment in the building It may also be due to your living area if it is very far away from the Radio controlled clock tower You are able to use the TEST function to look for a better location e Press TEST button SCAN is shown in the Information Window rr TINI ILI UN e Pick the unit to find a good location flashing The test is running and the Meteotime signal reception is good You are able to leave the device in this position flashing The test is running and the Meteotime signal reception is poor You need to keep on lo
11. rmation If no key is pressed the critical weather information will be toggle to display so as to make sure you are aware of the critical weather details 12 INDOOR OUTDOOR TEMPERATURE AND HUMITIDY READING e Press IN OUT keys to switch the reading of indoor or outdoor temperature and humidity reading i Li IN OUT J le A Wr gt A Jaci e Press MEM key to read the record of the maximum and minimum temperature e Press and Hold MEM key to CLEAR the record of the maximum and minimum temperature LINKING THE OUTDOOR THERMO HYGROMETER SENSOR WITH MAIN UNIT IF SIGNAL LOSS If the Main unit cannot receive the outdoor sensor signal the outdoor signal icon will change to qh e Press and Hold IN OUT button for 3 second and then the wave icon A will be flashed If the signal has been received again the outdoor signal icon will be A BACKLIGHT e Press Light key to turn on the LCD backlight for 8 seconds LOW BATTERY INDICATION When it is time to replace batteries the respective low battery indicator see graphics will appear next to the weather forecast for the display unit or next to the outdoor temperature for the outside sensor Low battery indicator icon for main unit low battery indicator icon for outdoor transmitter 13 Significance Significance Day Night Sunny Clear at night Heavy Rain a Dor Light Cloudy Frontal Storms ed
12. w minutes time and the date will appear However the transfer of the very large amount of data forecast for all regions and days will take much longer To completely receive all data will take up to 24 hours from the time of the initial setup FEATURES This package comes with a main unit which is Meteotime Weather Station and a remote outdoor Thermo hygrometer sensor This Meteotime Weather Station has equipped the thermo hygrometer sensor to measure the indoor temperature and humidity and also has a wireless outdoor thermo hygrometer sensor to measure the outdoor temperature and humidity Key Features e Weather Status for today and coming days for 60 30 regions e Precipitation Probability for Today e Wind Speed and Wind Direction for Today Single channel outdoor 433Mhz wireless Thermo hygrometer Indoor Thermo hygrometer e Sunrise and sunset display e Regional Day time temperature and Night time Temperature information The night temperature for the 4th day will not be displayed Critical Weather Alert e Radio controlled Clock and Calendar e Time zone setting e Blue Backlight e Powered by Four AA batteries for main unit and 2 AAA batteries for the outdoor sensor INTRODUCTION The Meteotime Weather Station LCD display shows Today Weather Information Window e In Outdoor Temperature amp Humidity e Tomorrow One day after and Two day after Weather Information e Information Window whic
13. yw Selection of a letter SET lt 1 gt Accept the selected letter and jumps to the next position OR lt 2 gt If you have not entered any letter in other words if only the cursor is flashing at the last position confirm the entry with this key and your place will also be included in the memory with immediate effect TEST One position back in the data entry process The place that you have selected to enter your own description will still exist under its own name e Press SET key to confirm and exit SET THE TIME ZONE LANGUAGE and CONTRAST Press and Hold SET for 3 second COUNT FY is shown in the Information Window e Press SET again then ZONE Q QHR is shown in the Information Window press A or W key to adjust the time zone e Press SET again then the language will be shown in the Information Window press A or W key to select your desired language There are total seven language for selection namely German English Spanish French Italiano Dutch Swedish Press SET again then QNTRAST 4 is shown in the Information Window press A or W key to adjust the LCD contrast Level e Press SET again and E X T will be shown at the information window After 4 seconds it will change to the City Date Time Mode REMARK If you do not have any selection into the Setup mode up to 60 seconds it will automatically exit the setup mode The Information Window will show City Sunrise
Download Pdf Manuals
Related Search
Related Contents
Guia do usuário RC4200UM On the following pages you will find the user manual for the Strider CP5-Series User Manual LA-012-W 取扱説明書 PDF(418KB) - JX日鉱日石エネルギー Copyright © All rights reserved.
Failed to retrieve file