Home

IMC Networks IE-Giga-MiniMc

image

Contents

1. Fiber Optic transmitters and receivers are extremely susceptible to contamination by particles of dirt or dust which can obstruct the optic path and cause performance degradation Good system performance requires clean optics and connector ferrules 1 Use fiber patch cords or connectors if you terminate your own fiber only from a reputable supplier low quality components can cause many hard to diagnose problems in an installation 2 Dust caps are installed at IMC Networks to ensure factory clean optical devices These protective caps should not be removed until the moment of connecting the fiber cable to the device Should it be necessary to disconnect the fiber device reinstall the protective dust caps 3 Store spare caps in a dust free environment such as a sealed plastic bag or box so that when reinstalled they do not introduce any contamination to the optics 4 If you suspect that the optics have been contaminated alternate between blasting with clean dry compressed air and flushing with methanol to remove particles of dirt Electrostatic Discharge Precautions Electrostatic discharge ESD can cause damage to any product add in modules or stand alone units containing electronic components Always observe the following precautions when installing or handling these kinds of products 1 Do not remove unit from its protective packaging until ready to install 2 Wear an ESD wrist grounding strap before handling any module
2. 465 3000 or FAX 949 465 3020 The end user shall return the defective product to IMC Networks freight customs and handling charges prepaid End user agrees to accept all liability for loss of or damages to the returned product during shipment IMC Networks shall repair or replace the returned product at its option and return the repaired or new product to the end user freight prepaid via method to be determined by IMC Networks IMC Networks shall not be liable for any costs of procurement of substitute goods loss of profits or any incidental consequential and or special damages of any kind resulting from a breach of any applicable express or implied warranty breach of any obligation arising from breach of warranty or otherwise with respect to the manufacture and sale of any IMC Networks product whether or not IMC Networks has been advised of the possibility of such loss or damage EXCEPT FOR THE EXPRESS WARRANTY SET FORTH ABOVE IMC NETWORKS MAKES NO OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED WITH RESPECT TO THIS IMC NETWORKS PRODUCT INCLUDING WITHOUT LIMITATION ANY SOFTWARE ASSOCIATED OR INCLUDED IMC NETWORKS SHALL DISREGARD AND NOT BE BOUND BY ANY REPRESENTATIONS OR WARRANTIES MADE BY ANY OTHER PERSON INCLUDING EMPLOYEES DISTRIBUTORS RESELLERS OR DEALERS OF IMC NETWORKS WHICH ARE INCONSISTENT WITH THE WARRANTY SET FORTH ABOVE ALL IMPLIED WARRANTIES INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HER
3. 1 VN LALAN Networks IE Giga MiniMc Operation Manual FCC Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a Class A computing device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which the user will be required to correct the interference at his own expense Any changes or modifications not expressly approved by the manufacturer could void the user s authority to operate the equipment The use of non shielded I O cables may not guarantee compliance with FCC RFI limits This digital apparatus does not exceed the Class A limits for radio noise emission from digital apparatus set out in the Radio Interference Regulation of the Canadian Department of Communications Le present appareil num rique n amp met pas de bruits radio lectriques d passant les limites applicables aux appareils num riques de classe A prescrites dans le Reglement sur le brouillage radio lectrique publi par le ministere des Communications du Canada Warranty IMC Networ
4. EBY LIMITED TO THE DURATION OF THE EXPRESS WARRANTY STATED ABOVE Every reasonable effort has been made to ensure that IMC Networks product manuals and promotional materials accurately describe IMC Networks product specifications and capabilities at the time of publication However because of ongoing improvements and updating of IMC Networks products IMC Networks cannot guarantee the accuracy of printed materials after the date of publication and disclaims liability for changes errors or omissions Table of Contents FCC Radio Frequency Interference Statement ccceeeceeseeeeeeeteeneeeeeeteeeeeneens Warranty POUL meilE G10 MinMes een Led Operation DC Power Supply Preeallionsnneessnss ea Specifications IMC Networks Technical Support Fiber Optic Cleaning Guidelines arena ae Electrostatic Discharge PECAN ons ser Safety Certifications About the IE Giga MiniMc The IE Giga MiniMc is a 10 100 1000 Auto Negotiating switching miniature media converter The fiber port always operates at 1000 Mbps Full Duplex the copper port Auto Negotiates the connected device s speed and duplex mode 10 100 1000 Mbps Half Duplex or 10 100 1000 Mbps Full Duplex including Flow Control The IE Giga MiniMc supports jumbo packets up to 1632 bytes The IE represents the unit s use as an Industrial Ethernet device which allows for extended temperature operation of 35 to 70 C 0 C to 50 C when using the
5. ZA NNm nNe JE G1g4 MimiMe E Caga NNininie E Cir a w AN IN N a Sh EN E N Y DIN Rail Mounting The IE Giga MiniMc ships from the factory with DIN c DIN rail The IE Giga MiniMc mounts perpendicular tc Use the supplied screws to attach the DIN clips to the IE Giga MiniMc then snap the converter to the DIN rail To remove the converter from the DIN rail use a flat head screwdriver in the slot to gently pry the converter from the rail VE Giga Nimiic Pi itn t Me Ina Ar The DIN clips are designed for use on a DIN 35 rail DC Power Supply Precautions The following precautions should be observed when installing chassis with DC power supplies 1 Check nameplate ratings to assure there is no overloading of supply circuits that could have an effect on overcurrent protection and supply wiring 2 When installing 7 50V DC rated equipment it must be installed only per the following conditions a Connect the equipment to a 7 50V DC supply source that is electrically isolated form the alternating current source The 7 50V DC source must be connected to a 7 50V DC SELV source b The maximum terminal voltage is 50V DC c Input wiring to terminal block must be routed and secured in such a manner that it is protected from damage and stress Do not route wiring past sharp edges or moving parts d A readily accessible disconnect device with a 3mm minimum contact ga
6. included AC adapter The IE Giga MiniMc converter offers plug and play operation including the AutoCross feature which automatically selects between a crossover workstation and straight through repeater hub connection depending on the connected device The IE Giga MiniMc can use either the included IMC Networks universal external power adapter with 100 to 240 10 V AC input or can be wired directly to the 7 50 V DC terminal block for extended temperature configuration There is an optional IE PowerTray 18 in which up to 18 IE Giga MiniMcs can be installed Installing the IE Giga MiniMc IE Giga MiniMec installs virtually anywhere as a standalone table top device on a DIN rail or an IMC Networks PowerTray 18 As a standalone device the end user can install IE Giga MiniMc in locations with extremely limited space Also included are Velcro strips to attach the device to most surfaces Installation Tip Several models of the IE Giga MiniMc support single strand fiber for operation Since single strand fiber products use optics that transmit and receive on two different wavelengths single strand fiber products must be deployed in pairs For example connect an IE Giga MiniMc TX SSLX SM1310 SC which has 1310 xmt and 1550 rcv to a product which has 1550 xmt and 1310 rcv e g IMcV Gigabit TX SSLX SM1550 SC The two connected products must also have the same speed and distance capabilities i e both are single mode 20km or both are
7. ks warrants to the original end user purchaser that this product EXCLUSIVE OF SOFTWARE shall be free from defects in materials and workmanship under normal and proper use in accordance with IMC Networks instructions and directions for a period of six 6 years after the original date of purchase This warranty is subject to the limitations set forth below At its option IMC Networks will repair or replace at no charge the product which proves to be defective within such warranty period This limited warranty shall not apply if the IMC Networks product has been damaged by unreasonable use accident negligence service or modification by anyone other than an authorized IMC Networks Service Technician or by any other causes unrelated to defective materials or workmanship Any replaced or repaired products or parts carry a ninety 90 day warranty or the remainder of the initial warranty period whichever is longer To receive in warranty service the defective product must be received at IMC Networks no later than the end of the warranty period The product must be accompanied by proof of purchase satisfactory to IMC Networks denoting product serial number and purchase date a written description of the defect and a Return Merchandise Authorization RMA number issued by IMC Networks No products will be accepted by IMC Networks which do not have an RMA number For an RMA number contact IMC Networks at PHONE 800 624 1070 in the U S and Canada or 949
8. or component If the wrist strap is not available maintain grounded contact with the system unit throughout any procedure requiring ESD protection 3 Hold the units by the edges do not touch the electronic components or gold connectors 4 After removal always place the boards on a grounded static free surface ESD pad or in a proper ESD bag Do not slide the modules or stand alone units over any surface WARNING Integrated circuits and fiber optic components are extremely susceptible to electrostatic discharge damage Do not handle these components directly unless you are a qualified service technician and use tools and techniques that conform to accepted industry practices Safety Certifications UL CUL Listed to Safety of Information Technology Equipment including Electrical Business Equipment CE The products described herein comply with the Council Directive on Electromagnetic Compatibility 2004 108 EC and the Council Directive on Electrical Equipment Designed for use within Certain Voltage Limits 2006 95 EC Certified to Safety of Information Technology Equipment Including Electrical Business Equipment For further details contact IMC Networks LISTED 5M80 ITE U L E156766 C o Class 1 Laser product Luokan 1 Laserlaite Laser Klasse 1 Appareil A Laser de Classe 1 European Directive 2002 96 EC WEEE requires that any equipment that bears this symbol on product or packaging must not be dispo
9. p shall be incorporated in the fixed wiring 3 Grounding reliable grounding of this equipment must be maintained Particular attention should be given to supply connections when connecting to power strips rather than direct connections to the branch circuit The Negative Terminal is common to the grounded case Specifications Fiber Connections Multi mode 1300nm Dual Fiber Single mode 1310nm 1550nm Dual Fiber Single mode 1310nm 1490nm Single Strand Fiber Single mode 1310nm 1550nm Single Strand Fiber Ethernet Connections e 10 100 1000 BaseT e Auto Negotiation e AutoCross e Flow Control e 1632 MTU e Full Line Rate Forwarding DC Input Voltage 7 to 50 V DC on DC terminal block 5 VDC on DC jack AC Wall Adapter 100 to 240 10 V AC input 5 V DC output 2 A max Power Tray 18 Slot AC for Miniature Converters 125W 20A 5V Power Consumption 600 mA Operating Temperature 31 to 158 F 35 to 70 C DC terminal block 32 to 122 F 0 to 50 C with IMC supplied AC wall adapter Storage Temperature 31 to 167 F 35 to 75 Humidity 5 to 95 non condensing 0 to 10 000 ft altitude Dimensions 0 83 H x 1 80 7W x 3 35 D 2 11 x 4 57 x 8 51 cm IMC Networks Technical Support Tel 949 465 3000 or 800 624 1070 in the U S and Canada 32 16 550880 Europe Fax 949 465 3020 E Mail techsupport imcnetworks com Web www imcnetworks com Fiber Optic Cleaning Guidelines
10. sed of with unsorted municipal waste This symbol indicates that the equipment should be disposed of separately from regular household waste It is the consumer s responsibility to dispose of this and all equipment so marked through designated collection facilities appointed by government or local authorities Following these steps through proper disposal and recycling will help prevent potential negative consequences to the environment and human health For more detailed information about proper disposal please contact local authorities waste disposal services or the point of purchase for this equipment BR aN 4K Networks 19772 Pauling Foothill Ranch CA 92610 2611 USA TEL 949 465 3000 FAX 949 465 3020 www imcnetworks com de j ISO 9001 2000 f Gat tp REGISTERED RoHS 2009 IMC Networks All rights reserved The information in this document is subject to change without notice IMC Networks assumes no responsibility for any errors that may appear in this document IE Giga MiniMc is a trademark of IMC Networks Other brands or product names may be trademarks and are the property of their respective companies Document Number 56 80830 00 A4 October 2009
11. single PLUS 40km LED Operation Each IE Giga MiniMc converter includes two LEDs located on the RJ 45 connector LED functions are as follows FX LNK ACT TX LNK ACT FX LNK ACT Glows green when a link is established on the fiber port blinks green when activity is detected on the fiber port TX LNK ACT Glows amber when a link is established on the copper port blinks amber when activity is detected on the copper port Powering the IE Giga MiniMc IE Giga MiniMc supports three powering options e A country specific AC power adapter included e The 4 terminal DC power block E PowerTray 18 DC Terminal Block Wiring Instructions The IE Giga MiniMc can be powered via the DC terminal block From a power source connect to any one positive and any one negative terminal on IE Giga MiniMc oOo 0 Se 5 to 20 VDC Ground common 7 to 50 VDC Connected to Chassis When using stranded wire the leads must be tinned and equivalent to a 16 AWG solid conductor The IE Giga MiniMc is protected against mis wiring if mis wired the IE Giga MiniMc will not function The IE Giga MiniMc is internally connected to the negative DC power terminals Cascading Power When installing multiple IE Giga MiniMc units on a DIN rail connect to one DC input source and then cascade from one DC block to the next until reaching the maximum electrical current available Sa Nnivc lE Giga MiniMe E Cir

Download Pdf Manuals

image

Related Search

Related Contents

HDC-P1 - Assistants Opérateurs Associés  BUH - Daikin  Owner`s Manual  Visualizza - Sanremo machines  Instruções de Operação - SEW  HP Compaq Elite 8300 CMT  Borland® StarTeam® 2006 - Borland Technical Publications  Advantech AKMB-G41 User Manual  IMP. CBS 8220 L  Renesas M34571T2-CPE User's Manual  