Home

Panasonic TY-LA1000 projection lamp

image

Contents

1. In exchange for defective Lamp Unit You must Mail In your Lamp unit during the warranty period This warranty only applies to products purchased and serviced in the United States or Puerto Rico This warranty is extended only to the original purchaser of a new product which was not sold as is Mail In Service For assistance in obtaining service in the United States please contact Panasonic Services Company Panasonic Plus Department 20421 84th Avenue South Kent WA 98032 Phone 1 800 833 9626 Fax 1 800 237 9080 If a Lamp unit defect occurs during the warranty period the purchaser will be required to furnish a sales receipt proof of purchase indicating date of purchase Also purchaser will be responsible for shipping the Lamp unit to the above address For assistance in Puerto Rico call Panasonic Puerto Rico 787 750 4300 or fax 787 768 2910 Limited Warranty Limits And Exclusions This warranty ONLY COVERS failures due to defects in materials or workmanship and DOES NOT COVER normal wear and tear or cosmetic damage The warranty ALSO DOES NOT COVER damages which occurred in shipment or failures which are caused by products not supplied by the warrantor or failures which result from accidents misuse abuse neglect mishandling misapplication alteration faulty installation set up adjustments misadjustment of consumer controls improper maintenance power line surge lightning damage modification or commercial use
2. such as in a hotel office restaurant or other business rental use of the product service by anyone other than a Factory Servicenter or other Authorized Servicer or damage that is attributable to acts of God THERE ARE NO EXPRESS WARRANTIES EXCEPT AS LISTED UNDER LIMITED WARRANTY COVERAGE THE WARRANTOR IS NOT LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM THE USE OF THIS PRODUCT OR ARISING OUT OF ANY BREACH OF THIS WARRANTY As examples this excludes damages for lost time travel to and from the servicer The items listed are not exclusive but are for illustration only ALL EXPRESS AND IMPLIED WARRANTIES INCLUDING THE WARRANTY OF MERCHANTABILITY ARE LIMITED TO THE PERIOD OF THE LIMITED WARRANTY Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts so the exclusions may not apply to you This warranty gives you specific legal rights and you may also have others rights which vary from state to state If a problem with this product develops during or after the warranty period you may contact your dealer or Servicenter If the problem is not handled to your satisfaction then write to the warrantor s Consumer Affairs Department at the addresses listed for the warrantor PARTS AND SERVICE WHICH ARE NOT COVERED BY THIS LIMITED WARRANTY ARE YOUR RESPONSIBILITY
3. Lamp Replacement CAUTION Because of the possibility of injury strictly follow the replacement procedure below This product has a High Intensity Discharge HID lamp that contains a small amount of mercury Disposal of these materials may be regulated in your community due to environmental considerations For disposal or recycling information please contact your local authorities or the Electronics Industries Alliance lt http Awww eiae org gt E Lamp replacement procedure 1 Turn power off wait until power indicator stops blinking red then unplug the power cord from the wall outlet and confirm that the area around the lamp unit has cooled down r POWER button POWER indicator STANDBY RY ONG LAMP indicator e Please wait more than one hour for lamp replacement If you need to replace the lamp more urgently The Projection display has a forced cooling feature After the POWER button is turned OFF and during the first minute of the normal cooling fan operation press the VOL button on the projection display and A button on the remote control at same time for more than 5 seconds The cooling fan operates for about 10 minutes The LAMP indicator flashes red 5 times every 5 seconds LSQC0334 C Remove the Front cover Place your fingertips under the Front cover and pull it from the projection display F
4. ess the POWER button on the projection display or the remote control to turn the unit on 2 While pressing the VOL button on the projection display hold down the PIP or SPLIT button on the remote control at same time for more than 5 seconds For models PT 50LC13 E PT 60LC13 PT 50LCX63 VOL PT 60LCX63 PT 43LCX64 pa and PT 50LCX64 PT 60LCX64 PIP For models PT 43LC14 PT 50LC14 PT 60LC14 SPLIT PLAY 3 When reset procedure LAMP TIME WAS is complete RESET TO 0 the screen on the right will appear This screen may be different from the actual screen Note When lamp time reset is finished the LAMP indicator goes out PANASONIC CONSUMER ELECTRONICS COMPANY DIVISION OF PANASONIC CORPORATION OF NORTH AMERICA One Panasonic Way Secaucus New Jersey 07094 PANASONIC PUERTO RICO INC Ave 65 de Infanteria Km 9 5 San Gabriel Industrial Park Carolina Puerto Rico 00985 Panasonic Lamp Unit Limited Warranty Limited Warranty Coverage LAMP Only If your Lamp unit does not work properly because of a defect in materials or workmanship Panasonic Consumer Electronics Company or Panasonic Puerto Rico collectively referred to as the warrantor will for the length of the period indicated below which starts with the date of original purchase warranty period replace it with a new lamp unit For ninety 90 days
5. ront cover Loosen the Lamp cover screw First read caution and warning labels on lamp cover Then loosen the lamp cover screw by using a screwdriver Lamp cover handle Screwdriver Lamp cover screw Loosen the lamp unit screw with a screwdriver Then grasp the lamp unit as shown in the diagram and slowly remove from the projection display Lamp unit screw Lamp unit handle A CAUTION Because the lamp unit is hot immediately after its use touching it may cause burns Please allow the lamp to cool before handling or replacing the lamp unit Insert the new lamp unit being careful of the insertion direction e Press on the arrow mark making sure insertion is done correctly Replace the Lamp unit and cover screws Tighten the lamp unit cover screw with a screwdriver Properly dispose of old lamp Please see the operating instructions for the projection display Attach the lamp unit and lamp unit housing door securely If the lamp unit and lamp unit housing door are not attached securely the protective circuit will be activated and the lamp will not turn on 7 Replace the Front cover After lamp replacement follow the procedure below Warning Perform lamp time reset only when the lamp has been replaced E Lamp time reset procedure 1 Be sure the power cord is plugged into a properly grounded wall outlet Then pr

Download Pdf Manuals

image

Related Search

Related Contents

Manual de Instruções  RedLab TEMP_de  Mode d`emploi - Accessolutions  BULK BREWING COFFEE MACHINE METOS COMBI User Manual    analyseurs de spectre portables, BK2650A, BK2652A, BK2658A, VP  Danvent DV, Danvent TIME Air Handling Units Transport  intext:installationshandbuch filetype:pdf  SPEECHEXEC - dikteringsbutiken.se  dbx  