1. carbon filters used this indicates that the hold 5 secs display from lt gt to lt C gt elapse timer function is switched on and Charcoal Filters are used Filter Replace Indicator Change Filters When the display starts flashing the Charcoal Filters require replacement display lt C gt flashes Re setting Function Once filters are replaced with hood off press and hold the display will appear hold 5 secs display from lt C gt to lt gt hold for approximately 5 seconds until on display disappears _ The Filter D Change Reminder is now re set and a new 120 hours elapse cycle is initiated Features amp Controls Charcoal Filters Change Indicator www zephyronline com Features amp Controls Metal Filters Clean Indicator Filter Clean Reminder Standard Metal Filters fitted Whether your hood is installed as an Exhaust or Purifying unit a set of metal filters are fitted by the factory These Metal Filters are intended to filter out residue from cooking They need not be replaced on a regular basis but are requiredito be kept clean The Filter Change Reminder function in the microprocessor will automatically indicate by a fashino CAS when the metal filters need to be cleaned after every 30 hrs of use Filters can be cleaned by hand with non abrasive soap or in a dishwasher Heavily soiled filters should also be soaked in grease cutting detergent such as Formula 409 or its equivalent
2. 45 elbow Subtotal column 1 Subtotal column 1 Total ductwork Maximum Duct Length For satisfactory air movement the total duct length of a 3 1 4 x 10 rectangular 6 or 7 diameter round ductshould not exceed 100 equivalent feet 2 min ducted 32 1 2 min recirc 36 max 51 9 27 32 min 28 max 36 min 97 max 123 36 DUCTING A minimum of 6 round or 3 1 4 x 10 rectangular duct must be used to maintain maximum air flow efficiency Always use rigid type metal ducts only Flexible ducts could restrict air flow by up to 50 Use calculation worksheet to compute total duct work ALWAYS when possible reduce the number or transitions and turns If long duct run is required increase duct size from 6 to 7 or 8 If a reducer is used install a long reducer instead of a pancake reducer Reduce duct size as far away from opening as possible If turns or transitions are required Install as far away from opening and as far apart between 2 as possible Minimum mount height between range top to hood bot tom should be no less than 28 Maximum mount height should be no higher than 36 It is important to install the hood at the proper mounting height Hoods mounted too low could result in heat damage and fire hazard while hoods mounted too high will be hard to reach and will loose its performance and efficiency If available
3. efficiency If improperly maintained residue from cooking will sift though filters and cause damage to hood blowers and other sensitive components and possibly clog duct work and create a fire hazard Filters Change Reminder Charcoal if fitted When your hood is installed as Recirculating Ductless unit it is fitted with a set of Chacoal Filters to purify any exhaust and fumes from cooking and re circulates the air within the home These Charcoal Filters are required to be replaced after every 120 hours of use The Filter Change Reminder function in the microprocessor needs to be switched on The microprocessor in the controls when set will elapsed and count usage time and indicate when charcoal filter replacement is needed every 120 hrs Filter Change Reminder Charcoal if fitted When your hood is installed as a Recirculating Ductless unit it is fitted with a set of Charcoal Filters to purify exhaust and fumes from cooking then re circulate the air within the home These Charcoal Filters are required to be replaced after every 120 hours of use The Filter Change Reminder function in the microprocessor needs to be switched on The microprocessor in the controls when set will elapse and count usage time and indicate by a flashing when charcoal filter replacement is needed Setting the Filter Change Reminder When Off hold for approx 5 seconds The display will change from exhaust mode to E purifying mode
4. also refer range manufacturer sheight clearance requirements and recommended hood mounting height above range Always check your local codes for any differences Minimum ceiling height of 97 Hood mounted at 28 above cooking surface Maximum ceiling height of 123 Hood mounted at 36 above cooking surface Minimum Duct Size Round 6 minimum Rectangular 3 1 4 x 10 minimum requires a 6 to 3 1 4 x 10 adapter not supplied DAMAGE SHIPMENT INSTALLATION Please fully inspect unit for damage before installation e If the unit is damaged in shipment return the unit to the store in which it was bought for repair or replacement e If the unit is damaged by the customer repair or replacement is the responsibility of the customer e If the unit is damaged by the installer if other than the customer repair of replace ment must be made by arrangement between customer and installer 2 Installation Mounting Height amp Clearance www zephyronline com Ducting Installation WARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls crawl spaces ceiling attics or garages All exhaust must be ducted to the outside unless using the recirculating option Use single wall rigid Metal ductwork only Fasten all connections with sheet metal screws and tape all joints w certified Silver Tape or Duct Tape Some Ducting Options side wall
5. source is not turned ON 1 Make sure the circuit breaker and the unit s power is ON 2 The power line and the cable locking connector is not connecting properly Check the power connection with the unit is connected properly The switch board and control board wirings are disconnected The switch board or control board is defective Make sure the wirings between the switch board and control board are connected properly Change the switch board or control board Light works but motor is not turning The motor is defective possible seized Change the motor The thermally protected system detects if the motor is too hot to operate and shuts the motor down The motor will function properly after the thermally protected system cool down Damaged condenser Change the condenser The unit is vibrating The motor is not secure in place Tighten the motor in place Damaged blower wheel Change the blower wheel The hood is not secured in place Check the installation of the hood The motor is working but the lights are not Defective halogen bulb Change the halogen bulb The light bulb is loose Tighten the light bulb The light bulb is not making a full contact Remove the bulb and disable power to the hood Bend the two metal brackets inside the bulb opening and bend them outwards to lower the socke
6. straight pipe attached to the air diverter NUCA plate to divert air through louvers on duct cover air diverter plate 6 straight pip wall pipe strap Ductless Recirculating Installation Features amp Controls Touch Controls amp Features www zephyronline com Blower On Off Display Speed level Delay Off Indicator Filter Clean Change OEO Lights On Off Hold to Dim Adjust 6 Speed Levels 15 Min Delay Off 1 Blower On Off By pressing the blower is switched On and Off When switched on the blower starts up on speed level 3 2 Speed Selection The 6 speed levels are selected by presing Oto decrease and D to increase speed level The display indicates level selected 3 Delay Off This is used for programmed shut down of blower and lights 15 minutes after the function is activated Press once a dot flashes in the lower right hand side of display BiJindicating the function is on The hood will completely shut down in 15 minutes 4 Lights On Off Dim Switch lights On and Off by pressing key once To dim lights press and hold for 2 seconds 5 Advance Display Functions Filters Clean Reminder Metal After every 30 hours of use the display will start flashing an HJ reminding you to clean the metal filters from residue and possible clogs The standard Metal Filters are required to be cleaned frequently and as recommended in order to maintain blower
7. the controls to determine when filters require cleaning Remove and clean by hand or in dishwasher Spray degreasing detergent and leave to soak if heavily soiled Dry filters and re install before using hood Replacing Metal Filters Should filters wear out due to age and prolonged use replace with following part number Hood Model Part No Filters in pkg ZVE E30S ZOF MO42 2 Metal Filter Dimensions ZVE E36S ZOF MO43 3 16 12 in x 9 12 in ZVE E42S Z0F M043 3 409 mm x 232 mm Also replace any damaged filter that has punctured or broken mesh bent or broken frame Maintenance Cleaning www zephyronline com Maintenance Lights Replacing Light Bulbs CAUTION Light bulb becomes extremely hot when turned on DO NOT touch bulb until switched off and cooled Touching hot bulbs could cause serious burns Make sure all power is turned off and bulbs are not hot Remove by turning bulb counter clockwise If bulbs are difficult to turn due to prolonged use firmly attach a glass suction cup approx the diameter of the bulb or use a rubber latex glove and turn counter clockwise Replacement bulbs are available at specialty lighting stores Purchase type JDR E27 50W halogen bulbs Or to order bulbs please call our service center 888 880 8368 or online parts store www zephyronline com Issue Cause What to do After installation the unit doesn t work 1 The power
8. 0101
9. I ZEPHR www zephyronline com Venezia ZVE E305 ZVE E365 ZVE E42S Model number Serial number Use Care and Installation Guide MAY07 0101 Zephyr Corporation www zephyronline com SAFETY NOTICE siciliani 2 LIST OF MATERIALS 3 INSTALLATION Ducting Calculation Sheet rin 4 Mounting Height and Clearance 5 DUCtHAA iii 6 Specifications i 7 Mounting the Hood and Duct Cover 8 Duetless Recirculating sr 9 FEATURES amp CONTROLS Touch Controls amp Features 10 Charcoal Filter Change Indicator 11 Metal Filter Clean Indicator n 12 MAINTENANCE CIEaningi s tate E E 13 Llano 14 TROUBLE SHOOTING sasa 15 LIST OF ACCESSORIES PARTS sicnnecnzasa 16 Table of Contents READ AND SAVE THESE INSTRUCTIONS www zephyronline com Important safety Notice WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT USE THIS FAN WITH ANY SOLID STATE SP EED CONTRO L DEVICE WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING a Use this unit only in the manner intended by the manufacturer If you have questions contact the manufacturer b Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked secure
10. a where it started 3 The fire departmentis being called 4 You can fight the fire with your back to an exit 5 Based on Kitchen Fire Safety Tips published by NFPA WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING a Installation Work and Electrical Wiring Must be Done by Qualified Person s In Accordance with all Applicable Codes and Standards Including Fire Rated Construction b Sufficient air is needed for proper combustionand exhausting of gases throughthe flue chimney of fuel burning equipmentto prevent back drafting Follow the heating equipmentmanufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American S ociety for Heating Refrigeration and Air ConditioningEngineers ASHRAE and the local code authorities c When cutting or drillinginto wall or ceiling do not damage electrical wiring and other hidden utilities d Ducted fans must always vent to the outdoors WARNING TO REDUCE THE RISK OF FIRE USE ONLY METAL DUCTWORK CAUTION To reduce risk of fire and to properly exhaust air be sure to duct air outside Do not vent exhaust air into spaces within walls or ceilings or into attics crawl spaces or garages WARNING TO REDUCE THE RISK OF SHOCK THIS FAN MUST BE INSTALLED WITH AN ISOLATING WALL CONTROL SWITCH Q 1 Hood 2 Metallic filters 3 ZVE E36 E42 2 Halogen light bul
11. bs 4 ZVE E36 E42 1 Duct cover assembly 2 pieces 1 Hardware bag 1 Duct cover mounting bracket 1 Packet of mounting screws w anchors 1 Butterfly damper NO DUCTING IS INCLUDED Note Zephyr recommends using 50LB EZ anchors if mounting hood onto drywall These are not provided but are readily available of most hardware stores List of Materials www zephyronline com Ductwork Calculation Sheet Installation Duct pieces Equivalent number Duct pieces Equivalent number length x used length x used 31 4 x10 1 Ft x i 6 Round 30 Ft x Rect wall cap straight with damper 7 Round 6 Round straight roof cap 7 Round 6 round to straight 3 1 4 x 10 rect transition 3 1 4 x 10 Rect 90 6 round to 3 1 4 x 10 rect transition 3 1 4 x 10 i i 90 elbow Rect 45 elbow elbow 7 Round 90 elbow 3 1 4 x 10 Rect 90 7 Round flat elbow 45 elbow 3 1 4 x 10 Rect 7 Round wall cap wall cap with damper with damper 3 1 4 x 10 Rect to 6 round transition 7 Round roof cap 3 1 4 x 10 7 round to Rect to x 3 1 4 x 10 6 round rect transition transition 90 elbow 7 round to 6 Round i 3 1 4 x10 90 elbow b EB rect transition 90 elbow 6 Round Subtotal column 2
12. cap w gravity damper mv A Soffit or crawl space wall cap ravity damp Roof Pitch w Flashing amp Cap pe LL pu air recirculating 1 87 2 78 19 11 16 10 37 13 87 21 21 32 min recirc 36 max 51 3 4 Elec K O ELECTRICAL WARNING All Electrical work must by performed by qualified electrician or person with similar technical know how and background For personal safety remove house fuse or open circuit breaker before beginning installation Do not use extension cord or adapter plug with this appliance Follow National electrical codes or prevailing local codes and ordinances Electrical Supply This appliance requires a 120V 60Hz electrical supply and connected to an individual properly grounded branch circuit protected by a 15 or 20 ampere circuit breaker or time delay fuse Wiring must be 2 wire w ground Please refer to Electrical Diagram labeled on product Cable Lock Pi A cable locking connector not supplied might also required by local codes Check with local requirements and codes purchase and install Aa appropriate connector if necessary Cable Lock 2 min ducted 32 1 2 Installation Specifications www zephyronline com Installation Mounting the Hood amp Duct Cover 1 Measure from range top t
13. ly fasten a prominentwarning device such as tag to the service panel CAUTION For General Ventilating Use Only Do not Use to Exhaust Hazardous or Explosive Materials and Vapors Take care when using cleaning agents or detergents Suitable for use in household cooking area WARNING TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE a Never leave surface units unattendedat high settings Boilovers cause smoking and greasy spillovers that may ignite Heat oils slowly on low or mediumsettings b Always turn hood ON when cooking at high heat or when cooking flambeing food i e Crepes Suzette Cherries Jubilee Peppercorn Beef Flambe c Clean ventilatingfans frequently Grease should not be allowed to accumulate on fan or filter d Use proper pan size Always use cookware appropriatefor the size of the surface element WARNING TO RE DUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING a SMOTHE R FLAMES witha close fitting lid cookie sheet or metal tray then turn off the burner BE CARE FUL TO PREVENT BUR NS If the flames do not go out immediatelyEVACUATE AND CALL THE FIRE DEPARTME NT b NEVER PICK UP A FLAMING PAN You may be burned c DO NOT USE WATER including wet dishcloths or towels a violentsteam explosion will result d Use an extinguisher ONLY if 1 You know you have a class ABC extinguisher and you already know how to operate it 2 The fire is small and contained in the are
14. nd re circulated back within the home We recommend to ALWAYS exhaust air outside of the home by employing existing or installing new duct work if possible The hood is most effective and efficient as an Exhaust unit Only when the exhaust option is not possible should you recourse to converting the hood into a purifying unit When converted to be a purifying unit a set of charcoal filters are required on top of its standard Metal Filter set Order according to its Part number below The standard Metal Filters are intended to capture residue from cooking and the optional charcoal filters help to purify fumes exhausted from cooking for re circulation RECIRCULATING KIT Required 1 Kit includes charcoal filters and air diverter plate Hood Model Part No Filters in pkg ZVE E30S ZRC 0050 2 ZVE E36S ZRC 0051 3 ZVE E42S ZRC 0051 3 2 Remove metal filters on hood Clip chacoal filters onto difuser panels 3 Re install metal filters 4 Turn on filter change indicator on control panel refer details pg 7 5 Charcoal filters must be replaced after every 120 hours of use or approximately every 2 to 3 months based on the average of 1 2 hrs of daily cooking time The microprocessor in the controls when set will elapsed and count usage time and Charcoal Filter Dimensions indicate when carbon filter replacement is 9inx64in required every 120 hrs 228 mm x 162 mm Ducting eee an 1 Install a 6
15. o hood bottom C L 28 min Level and mark line A 2 Plum and mark center line Duct Cover Bracket 3 Mark mounting height line B 10 3 8 from line A 4 Mark mounting spread from C L 9 7 16 9 7 16 5 Fasten E Z anchors to wall see below as marked Y C a aaa B 1 6 Fasten screws provided onto EZ anchors do not a fasten screws all the way 10 3 8 i A 7 Hang hood onto screws and hand tighten fig A 28 min MOUNTING THE DUCT COVER C L 1 Center and attach duct cover mount bracket on wall below ceiling or soffit 2 Mount telescopic duct covers onto hood and extend inner duct cover and fasten to bracket silence ninni e ali ee eee oe fig A EZ ANOHORS Tap EZ anchor tip into marked drywall locations turn with screw driver until seated flush Notewhenever possible the hood should be secured to wall studs lt C Use EZ anchors only on hollow drywall applications minimum drywall thickness 1 2 If a stud or wood surface is present fasten screws directly into stud or plywood For all other wall types concrete brick tiles etc use appropriate anchors for mounting Ductless recirculating is intended for applications where an exhaust duct work is not possible to be installed When converted the hood functions as a purifying hood rather than an exhaust hood Fumes and exhaust from cooking is drawn and filtered by a set of optional charcoal filters The air is then purified a
16. prior to cleaning Filter Clean Reminder When Tizio on display the metal Clean Filters filters installed are required to be cleaned display lt A gt flashes This will occur after every 30 hours of use Re setting Function Reset the Filter Clean Reminder timer when filters are cleaned and re installed with hood off Press and hold for approx 5 seconds the display will appear hold for ToReset approximately 5 seconds until A Jon dis f play disappears __ The Filter Clean hold 5 secs display from lt C gt to lt gt Reminder function is now re set and a new J 30 hours elapse cycle is initiated Surface Maintenance Clean periodically with hot soapy water and clean cotton cloth Do not use corrosive or abrasive detergent or steel wool scouring pads which will scratch and damage surface For heavier soil use liquid degreaser After cleaning you may use non abrasive stainless steel polish cleaners to polish and buff out the stainless luster and grain Always scrub lightly with clean cotton cloth and with the grain Do not use any product containing chlorine bleach Do not use orange cleaners Metal Filters The Metal Filters fitted by the factory are intended to filter out residue and grease from cooking They need not be replaced on a regular basis but are required to be kept clean Filters should be cleaned after every 30 hours of use Use the Filter Clean Reminder function on
17. r other than its intended purpose Damaged because of improper connection with equipment of other manufacturers Repaired or modified by anyone other than Zephyr s Authorized Agents What is Not Covered Consumable parts such as light bulbs filters and fuses Services outside of service area and the labor cost incurred in connection with the removal shipping and reinstallation cost nor does it cover any other contingent expenses The natural wear of finish and wear due to improper maintenance use of corrosive and abrasive cleaning products pads and oven cleaner products Chips dents or cracks due to abuse misuse freight damage or improper installation Service trips to your home to teach you how to use the product Damage of product caused by accident fire floods or act of God This warranty is valid in the United States and Canada It is non transferable and applies only to the original purchaser and does not extend to subsequent owners of this product Any applicable implied waranties including the warranty of merchantability are limited in duration to a period of express warranty as provided herein beginning with the date of original purchase at retail and no warranties whether express or implied shall apply to this product thereafter Have your product proof of purchase with date ready for warranty issues Or write to Zephyr Corporation Service and Warranty Department 395 Mendell Street San Francisco CA 94124 JANO7
18. t and make a complete contact The hood is not venting out properly The hood might be hanging to high from the cook top Adjust the distance between the cook top and the bottom of the hood within 24 and 32 range The wind from the opened windows or opened doors in the surrounding area are affecting the ventilation of the hood Close all the windows and doors to eliminate the outside wind flow Blocking in the duct opening or ductwork Remove all the blocking from the duct work or duct opening The direction of duct opening is against the wind Adjust the duct opening direction Using the wrong size of ducting Change the ducting to at least 8 or higher Metal filter is vibrating Metal filter is loose Change the metal filter Trouble Shooting Description Part Light Bulb JDR E27 Z0B 0011 Metallic Filters 2 pk ZOF M042 Metallic Filters 3 pk ZOF M043 Telescopic Back Splash 30 Z0S 0013 Telescopic Back Splash 36 Z0S 0016 Telescopic Back Splash 42 Z0S 0012 Wire Spice Rack 30 ZOR 0013 Wire Spice Rack 36 ZOR 0016 Wire Spice Rack 42 ZOR 0012 To order parts visit us online at www zephyronline com and go to the parts store Or call us at 888 880 8368 List of Parts and Accessories ZEPH R www zephyronline com Warranty TO OBTAIN SERVICE UNDER WARRANTY Staple
19. your receipt here or any Service Related Questions please call Proof of the original purchase 1 888 880 8368 date is needed to obtain service under the warranty TO OBTAIN SERVICE UNDER WARRANTY You must present proof of original purchase date Please keep a copy of your dated proof of purchase sales slip in order to obtain service under warranty One Year Service Repair Warranty For one year from date of original purchase we will provide free of charge service labor to repair any failed parts or components due to manufacturing defects One Year Parts Warranty For one year from date of original purchase we will provide free of charge nonconsumable replacement parts or components that failed due to manufacturing defects Consumable parts not covered by this warranty include Light Bulbs Metal and Charcoal Filters Who is Covered This warranty is extended to the original purchaser for products purchased for ordinary home use in the 48 mainland states Hawaii and Washington D C In Canada and Alaska this warranty is Limited There might be costs associated with shipping the products to our designated service locations or you might need to pay service technician s travel costs to have the appliance repaired in home This Warranty will be Voided when Product damaged through negligence misuse abuse accident Improper installation and failure to follow installation instruc tions When product is used commercially o