Toshiba PTSE3U Laptop User Manual
Contents
1. If there is no data in the memory A of the parameter writer though it is selected as the origin to copy data the display shows H and copying data is of course impossible When the memory B is selected in the same condition E r h appears on the display When the memory C is selected in the same condition E appears on the display E6580724 4 2 Simply copying function Data stored in the memory A B or C of the parameter writer can be copied to the inverter s memory with simple operation of two keys to select one of the memories A B and C Use this function to set the same parameters to more than two inverters What differs from the Copying function in Section 4 1 is the key operation and the contents of parameters to be copied are the same for both functions It is impossible to copy data from the inverter s memory to a memory of the parameter writer in this mode Note To copy data to the inverter s memory do it when the inverter is stopped If you copy data to the inverter while the inverter is running some of the parameters fail to be copied Furthermore make sure to check the copied data by executing data comparison 77 1 F between the source and the destination memories after the copying operation Operating procedure LED indication Key operation and description When the parameter writer is turned on as it is connected with the inverter I HL appears on the display first and
2. Do not install the product where it could be splashed with water and the like It could lead to electric shocks or fire The product must be used under environmental conditions prescribed in this instruction manual Using the product under conditions not specified by the instruction manual could lead to Mandatory breakdown A Cautions V Do not install the product in any place subject to vibrations or it could fall Prohibited Otherwise it can cause injury to people E6580724 Bi Caution on operation Prohibited Do not operate keys with a wet hand or wipe with a wet duster Not following this instruction could cause electrocution Do not shock the Parameter Writer do not fall down Not following this instruction could cause malfunction or breakdown Do not pull the transmission cable Not following this instruction could cause malfunction or breakdown Bl Caution on disposing of Parameter Writer Mandator A Warning Ww Dispose of the Parameter Writer as industrial waste Not following this instruction could cause injury Notes on operation NOTES Install the unit avoiding a place where ambient temperature or and humidity change sharply Arrange the transmission cable apart from the power cable of the inverter to prevent the inverter from malfunctioning to be caused by electromagnetic noise Install the unit on the panel of a cabinet if it is used as a remote keypad The unit not instal
3. status When tim appears on the display the selected memory is protected When i F F appears on the display the Selected memory is not protected Protecting the selected memory Each time the SFT key is pressed indication on the display changes between Lim protecting the selected memory and fF F cancelling protection of the Executing protection of the selected memory After selecting 7 4 protecting the selected memory by way of example with the SFT key press the ENT key The parameter writer starts protecting the selected memory canceling protection in case of H F F and indication of the display returns to Fair E If the ESC key is pressed the parameter writer returns to the status one before is different from that provided for other memories and is shown below With different inverter types capacities O Protection disabled write permitted ics Wl 12 o ts Write protected write prohibited Note When inverter types capacities are different copying operation of parameters including special parameters is prohibited ll E6580724 4 5 Memory initializing function Cl r A selected memory memory A B C or system memory of the parameter writer or all of them if selected are initialized by this function Operating procedure When the parameter writer is turned on as it is connected with the inverter C HL appears on the display f
4. parameter writer itself Before using the Parameter Writer carefully read this operation manual to make your Parameter Writer demonstrate its excellent performance ent irety and correctly After reading this operation manual carefully keep it at the side of the operator of the Parameter Writer for future inspection and maintenance Explanation of model number of Parameter Writer PWU 001Z 1 L Revision number Cable length Connection cable between inverter and parameter writer Z Without Model number of parameter writer Symbol of parameter writer Check of accessories The Parameter Writer is shipped together with the following accessories in the same package On opening the packing case check to see if the following accessories are contained or not 1 Operation manual of Parameter Writer 1 copy 2 Spacer length 20 mm 2 pcs sf Jg 3 Screw and nut for fixing I s Note Parameter Writer M3 x 30 mm 2 pcs each I The Parameter Writer Part Number PWU001Z is not provided with connection cable between the inverter and Option Unit This should be purchased separately d d rp Part number of connection cable Cable length between the Inverter and Option Unit CABO0011 1m 1 2m 4ft CABO0013 3m 3 6m 12ft CABO0015 5m 4 8m 16ft 1 14 E6580724 Carefully read the following notes Safety precautions On the inverter and in its instruction manual i
5. the display first and then in appears to indicate that the power supply is being initialized Lastly the display shows F 4 Selecting a desired function Select to L 1 F comparing function with the SFT key Each time the SFT key is pressed indication on the display changes from C OPH toL DTP comparing function P 0 E memory protecting function memory initializing function and to 47 4 again in this order Entering the selected function After selecting 7 P with the SFT key press the ENT key and 5 selecting inverter memory appears on the display Selecting a memory to compare its data with another Each time the SFT key is pressed indication on the display changes from m selecting inverter memory to Fi selecting memory A h Selecting memory B i selecting memory C and to 4 again in this order Select the copy destination area Entering the memory to compare its data with another After selecting m selecting inverter memory for example with the SFT key press the ENT key and nm A appears on the display Selecting a memory to compare its data with that of the previously selected memory Each time the SFT key is pressed indication on the display changes from jm A comparing data between inverter memory and memory A to fin bh comparing data between inverter memory and me
6. then im I appears to indicate that the power supply is being initialized Lastly the display shows P 4 Selecting and entering a memory to copy its data Press the key corresponding to the memory to select as the origin to copy data while F 4 is being displayed A key To copy data from the memory A to the inverter s memory B key To copy data from the memory B to the inverter s memory C key To copy data from the memory C to the inverter s memory When the memory A is selected to copy its data to the inverter s memory for example indication on the display changes from 7 P Y to A in copying data from memory A to inverter s memory Executing copying In the status that 4 4 is appearing on the display press the ENT key and the indication on the display changes to F of the communication number of the parameter being copied Copying is complete With completion of data copy n d appears on the display first and then _ of a check data check sum of the origin of copied data appears Value of the check data changes depending on the condition of the original data Ending copying Press the ENT key and indication on the display returns to 7 F Make sure to check with data comparison function 4 77 after operation If the ESC key is pressed the parameter writer returns to the status one before O When the memory protection function is a
7. TOSHIBA E6580724 Parameter Writer Operation Manual PWU001Z 1 Table of Contents NAMES AND FUNCTIONS OF MAIN PARTS TTTITTITTTITTITTITTTTTTTTTTTTTTTTTTTTTTTTTTI CONNECTION AND START UP IMI RON 4 1 Copying function Z PS 4 2 Simply copying function TTTITTTTTTTTTTTTTTTTT TIT TT ETT TTTTTTTITTTTTTTITTTTTTTITTTI u rmm 4 3 Comparing function Lir O 4 4 Memory protection function Fy u y 4 5 Memory initializing function L 4 6 Function to serve as remote keypad TTTTTTTTTTTTTTTTTTTTTTTTTTTTTTITTTTTTTTTTTTIT 12 INDICATIONS ON DISPLAY TITITITITITI e mb oO This Parameter Writer cannot use at TOSVERT VF S7 S7e inverter has a CPU whose version is V100 to V103 For checking the version number of the CPU refer to the Monitor paragraph in the instruction manual of the inverter NOTES 1 Make sure that this instruction manual is delivered to the end user of the Parameter Writer 2 Read this manual before installing or operating the Parameter Writer And keep it in a safe place for reference Toshiba Schneider Inverter Corporation Toshiba Corporation 1996 All Rights Reserved E6580724 Preface Thank you for purchasing the Parameter Writer PWUOO12Z for TOSVERT series inverter Using this product you can copy data from one place to another and then execute data comparison between the inverter and the parameter writer s memory or between the memories of the
8. arameters fail to be copied Furthermore make sure to check the copied data by executing data comparison 7 77 7 P between the source and the destination memories after the copying operation Operating procedure Key operation and description When the parameter writer is turned on as it is connected with the inverter I HC appears on the display first and then 4 E appears to indicate that the power supply is being initialized Lastly the display shows FY Selecting a desired function Select 417 4 copying function with the SFT key Each inis the SFT key is pressed indication on the display changes from CUPS AoE cone comparing function E memory protecting function L memory initializing function and to P 4 again in this order Entering the selected function After selecting P 4 with the SFT key press the ENT key and 5 selecting inverter memory appears on the display Selecting a memory to copy its data Select a memory to copy its data with the SFT key Each time the SFT key is pressed indication on the display changes from Selecting inverter memory to a selecting memory A 5 Selecting i C and to 4 again in this order Entering the memory to copy its data After selecting i selecting inverter memory by way of example with the SFT key press the ENT key and 4 H appears on the d
9. ctuated the parameter writer inhibits to copy data with 7 7k appearing on the display If there is no data in the memory A of the parameter writer though it is selected as the origin to copy data the display shows r H and copying data is of course impossible When the memory B is selected in the same condition b appears on the display When the memory C is selected in the same condition E appears on the display The same operation as below can be used to copy data from memory B or memory C of the parameter writer to the inverter N NRUV Since the A B and C keys are provided to be used exclusively for the simply copying function those keys cannot be used for other functions E6580724 4 3 Comparing function C GAP This function enables the operator to compare data stored in two memories that are selected from among four memories of the parameter writer s memories A B and C and the inverter s memory as well as to search a parameter which is different in the setting value from others The comparing function cannot be used for editing data because it is provided for searching parameters which are different in setting values from others Use the Remote keypad function described in Section 4 6 to edit data Operating procedure Ke LED indication Key operation and description When the parameter writer is turned on as it is connected with the inverter C HC appears on
10. e display first and then in appears to indicate that the power supply is being initialized Lastly the display shows Z 7 4 electing a desired function Select P ft memory protecting function with the SFT key Each time the SFT key is pressed indication on the display changes from C UP S copying end to i 1 7 19 comparing function P 4 memory protecting function memory initializing function and to P 4 again in this order Entering the selected function After selecting F with the SFT key press the ENT key and fn selecting inverter memory appears on the display Selecting a memory to protect its data Each time the SFT key is pressed indication on the display changes from 4 selecting inverter memory to H selecting memory A h selecting memory special parameter selection and to again in this order Select the memory to protect its data Enero the memory to protect its data After selecting m selecting inverter memory by way of example with the SFT P I selecting memory C GLP u in gu FF When the memory is Protecting operation of With the same inverter types capacities protected the display changes to n from u lA n u MCCn u pt n uo an u AZE 2 urr Laur aur key press the ENT key and the display shows the present memory protection
11. ecting inverter s memory for example with the SFT key press the ENT key and the parameter writer starts initializing the selected memory with indication of m appearing on the display When initialization of the selected memory is complete indication of the display returns to P H u agn ure If the ESC key is pressed the parameter writer returns to the status one before 4 6 Function to serve as remote keypad for VF S7 S7e series inverter whose CPU version is V104 or after The parameter writer can be used as an operation panel remote keypad of a VF S7 S7e series inverter whose CPU version is V104 or after by means of the procedure mentioned below For recovering the parameter writer s original function from the status to serve as remote keypad do the same operation as that for actuating the remote keypad function When the parameter writer is set to serve as a remote keypad refer to the operation manual of the inverter for operations of the remote keypad because operations are the same as those on the inverter s operation panel Bl Procedure to switch the parameter writer s mode to function as a remote keypad or to function as parameter writer Following to the procedure of 3 Connection and start up turn on the parameter writer while pressing the En key mM Checking the setting mode of the parameter writer for remote keypad function or parameter writer function When the parameter writer is turned
12. irst and then a iE appears to indicate that the power supply is being initialized Lastly the display shows F 4 Selecting a desired function Select L r memory initializing function with the SFT key Each time the SFT key is pressed indication on the display changes from LUGPHW copying function to 7 4 17 comparing function F memory protecting function 7 in this order Entering the selected function After selecting L r with the SFT key press the ENT key and 4 selecting memory A appears on the display Selecting a memory to initialize Select the desired memory to initialize with SFT key Each time the SFT key is pressed indication on the display changes from A selecting memory A to h selecting memory B selecting memo C 5 4 5 selecting all in molios status of factory setting including F in this order uneen Entering the memory to initialize LIRE After selecting Fl selecting memory A by way of example with the SFT key press the ENT key and F F appears on the display 4 n Initializing the selected memory un Each time the SFT key is pressed indication on the display alternately changes 2 DEF between to initialize selected memory and JF F not to initialize the selected memory Executing initialization of the selected memory After selecting 7 n sel
13. isplay Selecting a memory to transcribe copied data Select a memory to transcribe copied data with the SFT key Each time the SFT key is pressed indication on the display changes from in H copying data from inverter memory to memory A to m b copying data from inverter memory to memory B in C copying data from inverter memory to memory C and to 4 again in this order If the memory A is selected as the origin to copy data indications differently appear as shown in parentheses Entering the selected memory to transcribe copied data After selecting H selecting memory A by way of example with the SFT key press the ENT key and the display shows F _ _ _ that is the communication number of the parameter being copied Copying is complete With completion of data copy E n d appears on the display first and then of a check data check sum of the origin of copied data appears Value of the check data changes depending on the condition of the original data Ending copying Press the ENT key and indication on the display returns to i Make sure to check the data with data comparison function operation n pu ee E OFF after this If the ESC key is pressed the parameter writer returns to the status one before O When the memory protection function is actuated the parameter writer inhibits to copy data with F 7k appearing on the display
14. k sum error occurred this indication appears Write data other than zero to the memory If you press the STOP key while an alarm message is displayed 7 1 flickers for one second If you press the STOP key again when i r flickers the parameter writer will be reset 13 uuum 6 Resetting function Reset the computer inside the parameter writer as follows if an alarm occurs a u y n Ad s j plu i If STOP key is pressed while an alarm message is displayed L r flickers for one second If you press the STOP key again when r flickers the parameter writer will be reset Resetting method 7 Specifications Specifications PWUOO12 1 Service environment Indoor lower than 1000m above sea level not subject to direct sunlight corrosive or explosive gas vapor dust chips cutting oil grinding agent etc 10 C to 50 C 8 Warranty The Parameter Writer will be adjusted or repaired free of charge under the following conditions 1 When the Parameter Writer has a trouble under correct installation and operation within one year after delivery and the trouble clearly originated in the design or manufacture of the unit the manufacturer is responsible for the trouble and the unit will be repaired by it free of charge 2 The warranty applies to the delivered Parameter Writer only 3 The user will be charged for the following repair service though the term of the
15. led on the panel of a cabinet could cause the unit falling resulting in damage and malfunction of the unit Install a magnetic contactor etc to the power supply of the inverter so that an emergency stop can be executed securely from outside The integrity of data storage is guaranteed for up to 10 years The operating life of EEPROM data storage device is 10000 operations Do not execute writing operations more than 10000 times Do not turn off power or remove the connection cable between the inverter and the parameter writer while a copying operation of parameter writer is executed If the inverter power is turned off or the connection cable is removed while parameters are being copied data cannot be written correctly Do not copy data from the parameter writer to inverter while the inverter is running Some of the parameters cannot be written when the inverter is in operation Make sure to execute 1 F compare function to check copied data when Zi P 4 copy function is executed Depending on circumstances data writing of copying operation may not have been successful When a copying operation is executed between two inverters with different capacities some of the parameters that vary with the capacity of inverters will also be copied Therefore when you have executed a copying operation between the inverters with different capacities we suggest you initialize the copied parameters of the inverter in accordance
16. mory B nm D comparing data between inverter memory to memory C and to in Al again in this order If the memory A is selected as the memory storing the original data indications differently appear as shown in parentheses Entering the selected memory to compare its data with the original After selecting 4 selecting memory A to compare its data with that of the inverter s memory for example with the SFT key press the ENT key and the parameter writer starts comparing data of the two memories with each other cogo o Enng Executing comparing data searching different parameters cies After confirming that F oa a If no parameter different ot data in order of communication number refer to the Table of communication from the other is numbers When the parameter writer searches a parameter different from the searched other it discontinues comparing operation and shows the parameter s the display shows communication number in blinking numerals End Press the ENT again to continue the comparing operation Comparing is complete With completion of data comparison E m d appears on the display first and then _ ofa check data check sum of the original data appears Value of the check data changes depending on the condition of the original data Ending comparing Press the ENT key and indication on the display returns to i If the ESC key is pressed the parameter writer
17. mportant information is contained for preventing injuries to users and damages to assets and for proper use of the device Read the instruction manual attached to the inverter along with this instruction manual for completely understanding the safety precautions and adhere to the contents of these manuals Handling in general N W Never disassemble modify or repair the product Never Disassembling the inverter could cause electric shocks fire or injuries Disassemble For repairs call your agency Do not remove connectors when the power is on It could lead to electric shocks Do not put or insert foreign objects such as waste cable bars or wires into the product It could lead to electric shocks or fire Prohibited Do not splash water over the product It could lead to electric shocks or fire Wiring should be conducted after turning the inverter power off Turn off the power immediately in case any abnormalities such as smokes smells or abnormal noise are found Mandatory Neglect of these conditions could lead to fire For repairs call your agency Transportation and installation V Do not install or operate the inverter if it is damaged or any part is missing from it Operating the inverter in a defective condition could lead to electric shocks or fire For repairs call your agency Do not put any inflammable material near the product Prohibited It could catch fire if the product sparks because of a breakdown and the like
18. normally operated after the indication the alarm mode indication is automatically cancelled If the same indication appears after checking connection of the inverter s serial communication cable and resetting the parameter writer the unit needs to repair Alarm indications warning indications Indicated by blinking LED LED indication P Ht The target memory to copy data or to initialize is write protected You cannot copy data to the memory or initialize that memory The type of device is different different in type or capacity of inverter If you press the ENT key when you are copying between two inverters of different capacities the system executes a copying operation forcefully but the system ends the operation if you press the ESC key If you set 5 F system area parameters to 77 F F protection disabled with mo ni D rui memory protection function you cannot write data even if you press the ENT key If you have written data forcefully between two inverters with different capacities we suggest you execute a parameter initialization for each level of inverter capacity See the inverter instruction manual on how to initialize parameters When memory A or B or C is selected as the source of copying operation or when it is selected with comparison and protection functions with no data in either case in the memory including the case when power was turned off during the previous copying operation or when a chec
19. on and the PARAMETER WRITER lamp is on the parameter writer is set to function as the parameter writer When the REMOTE KEYPAD lamp is on the parameter writer is set to function as the remote keypad 12 E6580724 5 Indications on display Messages appearing on the display are classified into three namely title indications malfunction indications and alarm indications E Title indications function indications Indicated by LED lamps LED indication n di H memory A h memory B memory C in inverters memory 5 4 5 all memories 5 4 F Special data On Off status of memory protection function or memory initializing function ON to execute OFF not to execute Communication number of parameter Result of check sum hexadecimal number Terry 0 E3 E3 2z 3 Ta Pea eae Ma Dad Baar Lad y r Description RAM built in the parameter writer is abnormal If the same indication appears after resetting the parameter writer it needs to repair ROM built in the parameter writer is abnormal If the same indication appears after resetting the parameter writer it needs to repair E PROM built in the parameter writer is abnormal If the same indication appears after writing copying data again it needs to repair CPU of the parameter writer is abnormal If the same indication appears after resetting the parameter writer it needs to repair Abnormal communication When communication is
20. operation manual of the inverter Memory A key Exclusive key for simply copying In the simply copying function this key is used to specify the memory A of the parameter writer as the origin to transmit data In remote keypad function RUN key Memory B key Exclusive key for simply copying In the simply copying function this key is used to specify the memory B of the parameter writer as the origin to transmit data In remote keypad function STOP key Memory C key Exclusive key for simply copying In the simply copying function this key is used to specify the memory C of the parameter writer as the origin to transmit data In remote keypad function MON key SFT key To be used for selecting a function copying comparing protecting data or for selecting a memory from among inverter s memory memory A B and C of parameter writer In remote keypad function UP key ESC key To be used to return to the status one before In remote keypad function DOWN key ENT key To be used to decide a function or memory or to execute the decided function In remote keypad function ENT key 9 E6580724 Connection and start up Connect the Parameter Writer with the inverter according to the procedure mentioned below 1 Turn off the inverter and wait for 10 minutes or more Then make sure that the CHARGE lamp of the inverter is off Connect the communication connectors of the parameter writer to the inver
21. parameter writer can be used as an operation panel of the inverter Memory configuration The parameter writer has three memories of A B and C to retain three kinds of parameters for the Parameter writer inverter Communication cable between parameter writer i and inverter To be purchased separately To Inverter E6580724 2 Names and functions of main parts PARAMETER WRITER lamp When the parameter writer is set for the original function to write parameters this lamp is on REMOTE KEYPAD lamp When the parameter writer is set to function as a remote keypad this tamp is on SFT keys for parameter writer function Refer to the following table UP and DOWN keys for emote keypad function Refer to the following table ll Operation keys and their functions LED display Shows data and other indications PARAMETER WRITER REMOTE KEYPAD Keys for parameter writer function Refer to the following table Keys for remote keypad function ENT key common to parameter writer function and remote keypad function Refer to the following table Functions of operation keys explained in the following table are in the condition that the parameter writer is used for the original purpose to copy write compare and protect data When the parameter writer is used as a remote keypad respective operation keys function as same as operation keys on the inverter For details of those functions refer to the
22. returns to the status one before E6580724 i Table of communication numbers The communication numbers for basic parameters are as follows As to extended parameters the titles and communication numbers of parameters are the same See the inverter instruction manual Table of communication numbers Communication number Title Function Automatic acceleration deceleration time Pod if Aue Automatic torque boost Automatic environment Fuga LH d Operation command mode selection FUB Fnlg Speed setting mode selection FM terminal meter selection FUUG En FM terminal meter adjustment Funi LYP Standard setting mode selection FUB Pr Forward reverse selection At panel control only 10 E6580724 Doe The memory protection function protects the selected memory so as to prevent it from erroneous replacement of its data with different data copied from another memory When this function is actuated for a selected memory it inhibits transcribing copied data to the memory but permits to read data from the memory At the time of shipment or when all the memories are initialized by memory initialization function i r LED indications are as follows u ton u pn u pn u u MD u on au ton Ut O DELI O Lt O ure O E weve 4 4 Memory protection function Operating procedure When the parameter writer is turned on as it is connected with the inverter C HL appears on th
23. ter which has common serial option communication connector with the optional cable See the instruction manual of inverter Turn on the inverter and the parameter writer is automatically started up with the display being on When this unit is used for the parameter writer confirm that the PARAMETER WRITER lamp is on Or when this unit is used for the remote panel confirm the REMOTE PANEL lamp is on If a change from the PARAMETER WRITER function to the REMOTE PANEL function mutually takes place turn off the power of the inverter and confirm that the LED display on the operation panel is turned off Then turn on the power of the parameter writer while pressing the ENT key of the parameter writer When disconnecting the parameter writer from the inverter do it according to the step 1 of the above mentioned procedure HM Connection example of parameter writer and inverter Example of VF A7 Example of VF S7 GE E VF A7 Connector for common serial option E6580724 4 Functions in detail 4 1 Copying function ri Lun Data stored in a memory can be copied to another memory which memories are selected from among four memories that are the inverter s memory memories A B and C of the parameter writer Note To copy data to the inverter s memory do it when the inverter is stopped If you copy data to the inverter while the inverter is running some of the p
24. warranty is not expired 1 Trouble or damage caused by wrong operation unauthorized repair or modification 2 Trouble or damage caused by transportation dropping or wrong handling of the unit after it was delivered to the user 3 Trouble or damage caused by fire salt water breezes noxious gas earthquake flood or strong wind lightning abnormal mains voltage or other natural calamity 4 Trouble or damage caused by wrong use of the unit as it is used for a purpose other than the original application of the Parameter Writer 4 the case there is another warranty specially provided for the unit it has priority over the above mentioned articles ME
25. with the level of inverter s capacity See the inverter instruction manual on how to initialize parameters E6580724 1 Overview Following six functions are available with this parameter writer 1 Copying function Data can be copied from a memory to another memory among four memories three memories A B C of the parameter writer and one of the inverter 1 Data copy from parameter writer to inverter 2 Data copy from inverter to parameter writer 3 Data copy from a memory to another memory of the parameter writer Simply copying function Data stored in a memory of the parameter writer can be copied to the inverter s memory by simple operation of two keys Comparing function Data written on two memories among four memories three of the parameter writer and one of the inverter can be compared with each other 1 Comparing data of the parameter writer with data of the inverter 2 Comparing data of the inverter with data of the parameter 3 Comparing data of two memories of the parameter writer with each other Memory protecting function Data written on the inverter s memory and the memories A B and C of the parameter writer are protected by this function to inhibit data writing Memory initializing function A selected memory memory A B C or all of memories including system memory of the parameter writer if selected are initialized by this function 6 Function to serve as remote keypad The