Home

Solid State Logic XR622 Stereo System User Manual

image

Contents

1. X Rack Master Module E7 Connector Details Ins Rtn Ext Mon Alt Mon Location Rear Panel Ins Snd Mix Rec Fol Mon Conn Type 25 pin D Type Female Location Rear Panel Conn Type 25 pin D Type Female Pin Description Cet 1 Alt Monitor Out Right ve 14 Alt Monitor Out Right ve 8 2 OV 15 Alt Monitor Out Left ve 3 Alt Monitor Out Left ve 7 16 OV 4 Main Monitor Out Right ve 17 Main Monitor Out Right ve 6 5 OV 18 Main Monitor Out Left ve 6 Main Monitor Out Left ve 5 19 OV 7 External Input Right ve 20 External Input Right ve 4 8 OV 21 External Input Left ve 9 External Input Left ve 3 22 OV 10 Mix Insert Return Right ve 23 Mix Insert Return Right ve 2 11 OV 24 Mix Insert Return Left ve 12 Mix Insert Return Left ve 1 25 0V 13 n c Pin Description Cct 1 Follow Monitor Right ve 14 Follow Monitor Right ve 8 2 OV 15 Follow Monitor Left ve 3 Follow Monitor Left ve 7 16 OV 4 Record Output Right ve 17 Record Output Right ve 6 5 OV 18 Record Output Left ve 6 Record Output Left ve 5 19 OV 7 Mix Output Right ve 20 Mix Output Right ve 4 8 OV 21 Mix Output Left ve 9 Mix Output Left ve 3 22 OV 10 Mix Insert Send Right ve 23 Mix Insert Send Right ve 2 11 OV 24 Mi
2. Master module No other Solid State Logic products are covered by this document and the performance of other Solid State Logic products can not be inferred from the data contained herein Measurement Conditions For each set of figures on the following pages the specific unit and test setup will be stated at the beginning of that section Any changes to the specified setup for any particular figure s will be detailed beside the figures to which that difference applies Measurement References Unless otherwise specified the references used in this specification are as follows e Reference frequency 1kHz e Reference level OdBu where 0dBu 0 775V into any load e Source impedance of Test Set 50Q e Input impedance of Test Set 100kQ e All unweighted measurements are specified as 22Hz to 22kHz band limited RMS and are expressed in units of dBu e All distortion measurements are specified with a 36dB Octave low pass filter at 80kHz and are expressed as a percentage e The onset of clipping for headroom measurements should be taken as 1 THD e Unless otherwise quoted all figures have a tolerance of 0 5dB or 5 e All measurements are made with the operating level switch set for 4dBu Mix Bus Performance Signal applied to one channel of an X Rack Line Input module and routed to Mix Bus Signal measured on Mix Output All other inputs un routed from the bus under test Mix Bus Gain control set to 0dB Gain Continuously variable fro
3. Press and hold SETUP MIDI until the SETUP MIDI LED flashes e Use the D Pot to select z DIM Level Press the D Pot to select this option e Use the D Pot to set the required level between 3dB and 30dB e Press the D Pot once more to set the selected value and return to the setup menu or press and hold SETUP MIDI until the SETUP MIDI LED stops flashing to return to normal operation MIDI Remote Control Controlling the soft controls see next page for list on the XR622 Master module via MIDI requires MIDI remote mode to be enabled Optionally the X Rack can be configured to use one or all default MIDI channels and to map different MIDI controllers to any of the soft controls Selecting MIDI remote mode To select MIDI remote mode e Press and hold SETUP MIDI until the SETUP MIDI LED flashes e Use the D Pot to select Remote Mode Press the D Pot to select this option e Use the D Pot to select 7 i The X Rack monitor controls listed below will now respond to MIDI controller messages e Press the D Pot once more to set the selected value and return to the setup menu or press and hold SETUP MIDI until the SETUP MIDI LED stops flashing to return to normal operation Once MIDI remote mode is selected the unit will behave as normal until a MIDI controller message corresponding to one of the soft controls is received This will lock out all of the soft front panel controls retaining the current sett
4. a MIDI controller to the selected function by operating the required MIDI controller Repeat the operate assign process for all required controls Press the D Pot again to leave this option and return to the setup menu or press and hold SETUP MIDI until the SETUP MIDI LED stops flashing to return to normal operation Switch assignments can be reset to the system defaults by pressing COPY DEL when in MIDI Remote Learn mode the Empty LED indicating when the assignments have been deleted Only single controls can be mapped to a MIDI controller Therefore mapping an X Rack control to a MIDI controller which is already in use will remove the previous mapping The original X Rack control will require re mapping itself before it can be controlled again F 4 6 Level Compensation Each of the Insert Send Mix Bus Record Bus and Monitor outputs are provided with level compensation for driving low 600Q inputs Level compensation is activated by removing a jumper for each output as follows Page F 4 60022 Output Level Compensation Link Output LK1 Alt Main Monitor Right LK2 Record Bus Left LK3 Record Bus Right LK4 Alt Main Monitor Left LK5 Insert Send Left LK6 Insert Send Right LK7 Mix Bus Left LK8 Mix Bus Right X Rack Master Module F5 E5 1 F5 2 F5 3 F5 4 Performance Specification The following page contains audio performance specification figures for the X Rack
5. Level Tracking Equipment Required Test Signal Input and Output Unit Setup Adjustment F6 2 Meter Level Equipment Required Test Signal Input and Output Unit Setup Adjustment Calibrated audio oscillator and audio level meter 1kHz sinewave 24dBu Oscillator to Insert Return Left Output to the audio level meter from Mix Bus Output use Left or Right as instructed below Select INS and set MIX LEVEL to centre Measure Mix Bus Output Left and note the reading Connect the oscillator to Insert Return Right Measure Mix Bus Output Right and adjust VR6 TRACKING for a level which matches that measured in step 1 Calibrated audio oscillator and audio level meter 1kHz sinewave 24dBu Oscillator to Insert Return Left Output to the audio level meter from Follow Mon Output use Left or Right as instructed below Select INS and set MIX LEVEL to maximum Select Measure the Left Follow Mon Output Adjust the oscillator level to obtain 24dBu if necessary Adjust VR5 0dB LEFT so that that the top left hand red LED on the bargraph meter just illuminates 3 Connect the oscillator to Insert Return Right Measure the Right Follow Mon Output Adjust the oscillator level to obtain 24dBu if necessary Adjust VR4 0dB RIGHT so that that the top right hand red LED on the bargraph meter just illuminates Page F 6
6. N Folion put and the Mix Bus Insert Return The right hand connector provides Mix and Record Bus outputs along with the Mix Bus Insert Send and a Follow Monitor pre level control output All outputs apart from the headphone output operate at a nominal level of 4dBu and are configured to drive standard line level inputs Level compensation for feeding 600Q inputs from the Bus Insert and Monitor outputs is provided by removable jumpers refer to Section F 3 4 for details Operation As well as a compact stereo monitor section the X Rack Master module contains the mix amps and outputs for the X Rack s internal Mix Record and Solo AFL busses The Mix bus is intended to be used as the main mix bus and includes a balanced insert point immediately before the Mix level control The Record bus provides a direct path to a DAW or any other recorder allowing the Mix bus to be used to provide a monitor mix while recording one or more inputs via the Record bus If the X Rack is fitted with XR621 Mic Amp modules these can be routed directly to the Record bus using the REC L and REC R switches on the XR621 module Mix Section This section carries all of the Mix bus controls the MIX LEVEL control allows the overall gain of the Mix bus to be adjusted the Record bus level is fixed The INS switch brings the Mix Bus Insert Return into circuit the Insert Send is permanently active whil
7. Please Note Solid State Logic SOUND 1 VISION pogic SUPERANALOGUE Super Analogue Outboard XR622 X Rack Master Module User s Guide This documentation package contains the User s Guide for your new X Rack Master module Depending on the age of your X Rack these pages may already be present in your X Rack Owner s Manual please check to see if these pages match your Manual If they do not these pages should be filed alongside it The XR622 X Rack Master module operates in conjunction with the XR625 X Rack Mic Amp and XR623 X Rack Line Return modules X Rack units prior to serial number XRKO110 are compatible with the X Rack Master module but may require a small modification to the buscard if the SOLO LED is permanently illuminated resistors R1 and R2 will need removing In addition any Mic Amp or Line Return module s must be fitted immediately to the left of the Master module later X Rack units do not have this limitation and modules may be freely placed anywhere in the later X Rack units For correct operation of this module your X Rack unit must be running V1 2 0 or later software Please refer to your X Rack Owners Manual for instructions on how to check the current software version and how to obtain and install a newer version if required There may be a newer version of the X Rack Owner s Manual available for download from our website www solid state logic com 8256XROFOB X Rac
8. ings until a corresponding controller message is received The right hand decimal point in the display window lights to show that the unit is in MIDI remote active mode Changing the MIDI channel Press and hold SETUP MIDI until the SETUP MIDI LED flashes e Use the D Pot to select 7 MIDI Setup Press the D Pot to select the MIDI Setup menu e Use the D Pot to select MIDI Channel Press the D Pot to select this option e Use the D Pot to set the MIDI Channel to listen to 9 to 16 orf for all Press the D Pot to leave this option The default value is all Changing the MIDI controller assignments The default controller mapping is shown below Default MIDI Controller Mapping MIDI Controller Master Module Control MIX REC EXT ALT MONO DIM CUT AFL Level Monitor LEVEL AND FF WwW KN Page F 3 X Rack Owner s Manual Optionally MIDI controllers can be mapped onto different Master module functions To do this Press and hold SETUP MIDI until the SETUP MIDI LED flashes Use the D Pot to select 7 MIDI Setup Press the D Pot to select the MIDI Setup menu Use the D Pot to select i MIDI Remote Learn and press SAVE to enable learn mode Operate any one of the soft controls on the XR622 Master module This will cause the LED of the selected control to flash the SEL LED will flash if either of the potentiometers have been chosen Assign
9. k Master Module Fl F2 BS E3 1 Master Module Introduction Used in conjunction with the XR623 X Rack Line Return module the XR622 X Rack Master module provides a complete small scale mix and monitor system for studios seeking a compact solution for mixing and monitoring in the analogue domain A single X Rack can provide up to 28 line level inputs Additional racks can be connected via the MIX BUS LINK connector on the rear of the X Rack unit allowing additional inputs to be added to the system if required X Rack units prior to serial number XRKO110 are not equipped with a MIX BUS LINK connector The X Rack Total Recall system allows session setups to be recalled instantly and can be archived as a MIDI SysEx dump to any MIDI sequencer The monitor section controls can also be controlled remotely using MIDI controller commands from any MIDI controller Up to three racks can be connected to an AWS 900 or AWS 900 and integrated with the AWS 900 Total Recall system via the serial port Connecting the MIX and REC outputs of the XR622 to the MIX and REC Insert Returns of the AWS 900 and selecting INSERT SUM mode allows almost unlimited expansion of the number of line level inputs to the console Connection The rear panel of the module carries a pair of 25 way D connectors The left hand INSRTN INS SND MIX connector provides the main and alternate Monitor outputs as well as a stereo External REC ey i A WO
10. m to 0dB THD Noise lt 0 005 from 20Hz to 10kHz 24dBu applied 0dB gain lt 0 008 at 20kHz Frequency Response 0 1dB from 20Hz to 20kHz 3dB at 150kHz Equivalent Input Noise lt 88dBu Input terminated with 150Q Record Bus Performance Signal applied to one channel of an X Rack Line Input module and routed to Record Bus Signal measured on Record Output All other inputs un routed from the bus under test THD Noise lt 0 005 from 20Hz to 20kHz 24dBu applied 0dB gain Frequency Response 0 1dB from 20Hz to 20kHz 3dB at 150kHz Equivalent Input Noise lt 88dBu Input terminated with 150Q Page F 5 X Rack Owner s Manual E6 Calibration Information The X Rack Master module is factory calibrated and should only need calibration if a potentiometer or other component has been replaced or if it is suspected that there is a problem with calibration In each of the following instructions it is assumed that the lid of the X Rack has been removed and that power has been applied It is also assumed that unless otherwise specified all switches are released and all front panel potentiometers are at unity or minimum position as appropriate The required accuracy for each adjustment will be specified along with the target value All level and distortion measurements should be made with audio band 20Hz to 20kHz filters unless otherwise specified All presets are accessible from the top of the unit F6 1 Mix
11. st the SUM REC and INS SUM switches allow the Record bus and Insert Return to be summed with the Mix bus to allow for summing of additional mix sources The MON switch enables the Mix output to be replaced with whichever source s have been selected for the Monitor section X Rack Owner s Manual E3 2 B3 3 Page F 2 Monitor Section The Monitor Section enables the Mix and Record busses or a stereo external input to be monitored the source to monitor being set by either the MIX REC or EXT switches either separately or together allowing great flexibility in recording and monitoring signals The EXT input would normally be playback from the main recorder or DAW The selected monitor signals can be routed back to the Mix output using the MON switch in the Mix Section allowing composite mixes to be easily recorded back to the master recorder or DAW ADC If one of the SOLO switches on any other X Rack modules is active the SOLO LED will illuminate and the AFL bus will be switched to the monitor output in place of the selected signal The level of the AFL signal can be adjusted with the AFL control The overall monitor level is set by the LEVEL control and the MONO switch allows quick mono compatibility checking The DIM and CUT switches provide either partial between 3 and 30dB or full attenuation of the monitored signal as required Me
12. tering of the selected source or sources is provided by the stereo bargraph meter which measures the signal level immediately prior to the LEVEL control Two sets of stereo loudspeaker outputs plus a headphone amplifier are provided The headphone socket is driven by a fixed gain amplifier immediately post the LEVEL control and is un affected by the loudspeaker ALT switch Expansion Each of the three X Rack busses Mix Record and Solo AFL are accessible externally through the MIX BUS LINK connector on the rear of the X Rack Additional X Racks can be connected via this connector allowing additional inputs to be mixed together and feed a single Master module The pinout for this connector is detailed in Section 5 2 of the X Rack Owner s Manual if the connector listing is not present in your manual a more recent copy may be downloaded from the Solid State Logic website www solid state logic com Only one XR622 master module is required per system connecting two or more X Rack units fitted with XR622 modules together will cause serious gain errors and distortion though it will not damage the system electronics F4 F 4 1 F4 2 F43 F44 F4 5 X Rack Master Module Configuration Dim Level The attenuation applied to the monitor signal when the DIM switch is active is set by the Total Recall processor The default level is 15dB it can be adjusted as follows e
13. x Insert Send Left ve 12 Mix Insert Send Left ve 1 25 OV 13 n c Please note that the D type connector binding posts fitted to the X Rack Master Module are 4 40 UNC thread Headphones Location Front Panel Conn Type Stereo 1 4 Jack Socket Pin Description Tip Left Ring Sleeve OV PL2 Location Internal Conn Type 16 pin IDC Plug Pin Description n a For Future Expansion Page F 7 X Rack Owner s Manual F8 Physical Specification Depth 200mm 7 9 inches including front panel knobs excluding connectors 275mm 10 9 inches including front panel knobs and connectors Height 171mm 6 75 inches Width 35mm 1 4 inches front rear panels 49mm 1 9 inches overall width front and rear panels are offset Weight 260g 9 5 ounces Boxed size 190mm x 290mm x 70mm 7 5 x 11 5 x 2 5 Boxed weight 460g 16 5 ounces All values are approximate F9 Environmental Specification As per X Rack see page 19 Page F 8

Download Pdf Manuals

image

Related Search

Related Contents

Broad View - Audio General Inc.  Moog Videolarm QMRT2-70NA surveillance camera  Bedienungsanleitung Servomat Steigler Luce 600 PB  Tristar Food steamer  Pfaff 153 User's Manual  Installation and operating instructions for Vexve AM20  User`s Manual - INHECO Industrial Heating & Cooling GmbH  LES TARIFS des séries RED de SFR  DQD-208J  Plena Mixer Amplifier - Bosch Security Systems  