Home
Frigidaire 318201724 Range User Manual
Contents
1. NOTA Asegurese de quitar _ la banda de puesta a tierra provista Figura 4 INSTRUCCIONES PARA INSTALACION DE LA ESTUFA ELECTRICA DE 30 Conexi n el ctrica directa al cortacircuito a la caja de fusibles o la caja de empalmes Si el aparato est conectado directamente al cortacircuito a la caja de fusibles o a la caja de empalmes use un cable blindado flexible o no met lico recubierto de cobre con alambre a tierra Provee una abrazadera releva de anclaje hom logo UL a cada extremidad del cable A la extremidad del electrodom stico el cable pase a trav s del agujero de la conexi n directa ver figura 4 en el cord n de la placa de montaje El tama o de los alambres alambre de cobre solamente y las conexiones deben estar conforme al r gimen del electrodom stico Donde los c digos locales permitan conectar el conductor de puesta a tierra del electrodom stico al neutral blanco vea figura 5 1 Desconecte el suministro el ctrico 2 Siga las instrucciones en la p gina anterior para la conexi n del alambre de cuatro conductores a la cocina fig 4 3 Enel cortacircuito la caja de fusibles o la caja de empalmes Fig 5 a Conecte el alambre verde o cobre desnudo el alambre blanco del cable del electrodom stico y el alambre neutral blanco juntos b Conecte los dos alambres negros juntos c Conecte los dos alambres rojos juntos Cable de la fuente de al
2. NOTE Be sure to remove the supplied grounding strap _ gt Figure 4 30 ELECTRIC RANGE INSTALLATION INSTRUCTIONS Direct Electrical Connection to the Circuit Breaker Fuse Box or Junction Box If the appliance is connected directly to the circuit breaker fuse box or junction box use flexible armored or nonmetallic sheathed copper cable with grounding wire Supply a U L listed strain relief at each end of the cable At the appliance end the cable goes through the Direct Connection Hole see Figure 4 on the Cord Mounting Plate Wire sizes copper wire only and connections must conform to the rating of the appliance Where local codes permit connecting the appliance grounding conductor to the neutral white wire see Figure 5 1 Be sure that no power is supplied on the cable from residence 2 Follow instructions on previous page for Four Conductor Wire Connection to Range Fig 4 3 In the circuit breaker fuse box or junction box Fig 5 a Connect the green or bare copper wire the white appliance cable wire and the neutral white wire together b Connect the 2 black wires together c Connect the 2 red wires together Cable from Residence Neutra white Wire Black Wires Junction Box White Wire Green 4 U L listed Conduit or Bare Copper Connector or CSA Wire Cable from listed Appliance NOTE Be sure to remove the supplied grounding strap
3. _ gt gt Figure 5 3 Wire Grounded Neutral Electrical System Example Junction Box Where local codes DO NOT permit connecting the appliance grounding conductor to the neutral white wire or if connecting to 4 wire electrical system see Figure 6 1 Be sure that no power is supplied on the cable from residence Follow instructions on previous page for Four Conductor Wire Connection to Range Fig 4 In the circuit breaker fuse box or junction box Fig 6 a Connect the white appliance cable wire to the neutral white wire b Connect the 2 black wires together c Connect the 2 red wires together d Connect the green or bare copper grounding wire to the grounding wire of the circuit breaker fuse box or junction box Cable from Residence Green or Bare Copper Wire ze White Wire Black Wires Green or Bare N Copper Wire i White Wire Junction Sy Listed Conduit Box Connector or CSA Cable from isted Appliance NOTE Be sure to remove the supplied grounding strap _ _ Figure 6 4 Wire Electrical System Example Junction Box 30 ELECTRIC RANGE INSTALLATION INSTRUCTIONS 5 Leveling the Range A Install an oven rack in the center of the oven B Place a level on the rack see Figure 7 Take 2 readings with the level placed diagonally in one direction and then the other Level the range if necessary by adjusting the 4 leg levelers with a wrenc
4. n 1996 NEC en casa sobre ruedas o veh culo recreativo donde el c digo local no permite el atterizaje a trav s del cable neutro blanco o en Canad remueva la correa de aterrizaje del marco y corte el otro extremo cerca de la terminal de neutral Conecte el electrodom stico de la forma usual INSTRUCCIONES PARA INSTALACION DE LA ESTUFA ELECTRICA DE 30 Conexi n del cable a tres alambres la cocina Si los c digos locales permiten la conexi n del conductor a tierra del armaz n al alambre neutral del cable de bronce del suministro el ctrico vea figura 3 1 Retire los tornillos de la parte baja de la cubierta del cable trasero cubierta de acceso para tener acceso al bloque de conexi n del borne terminal 2 Utilizar los tuercas suministraron en el paquete de la literatura para conectar la parte neutral del cable de bronce de suministro el ctrico al terminal plateado que se encuentra al centro del bloque terminal y conectar los otros alambres a los terminales externos Aparee los alambres y los terminales seg n el color alambres rojos conectados al terminal derecho alambres negros conectados al terminal izquierdo vea figura 3 3 Baje la cubierta del terminal y vuelva al colocar los tornillos Terminal plata la placa de montaje _ LES gt Neutro Alambre Blanco Banda de puesta a tierra Alambre Negro 1 1 8 2 9 cm Agujero de la conexi n directa
5. Retira la arandela pre cortada para 1 3 8 3 5 cm Dia agujero Una arazadera de releva provista debe de estar instalada a est ubicaci n Hacia el 240 V Recept culo Figura 3 Conexi n del cable de cuatro conductores a la cocina 1 Retire los tornillos de la parte baja de la cubierta del cable trasero cubierta de acceso para tener acceso al bloque de conexi n del borne terminal 2 Retire la correa de la base del bloque terminal y del armaz n del electrodom stico Retenga el tornillo de la base 3 Utilizar los tuercas suministraron en el paquete de la literatura para conectar el alambre de tierra verde del cable de bronce del suministro el ctrico al armaz n del electrodom stico con el tornillo de la base usando el hoyo del armaz n por donde retir la correa de la base vea figura 4 4 Conecte el alambre neutral blanco del cable de cobre del suministro el ctrico al terminal plateado del centro del bloque terminal y conecte los otros alambres a los terminales externos 5 Baje la cubierta del terminal y vuelva al colocar los tornillos Terminal plata SINE Bloque terminal Alambre Negro 1 1 8 2 9 cm Dia Agujero de la conexi n directa Retira la arandela pre cortada para 1 3 8 3 5 cm dia agujero Alambre Blanco cable de cobre Una arazadera de releva provista debe de estar instalada a est ubicaci n Hacia el 240 V recept culo
6. _____ provista Figura 6 INSTRUCCIONES PARA INSTALACION DE LA ESTUFA ELECTRICA DE 30 5 C mo nivelar la estufa A Coloque una parilla del horno en el centro del horno B Ponga un nivel sobre la parrilla Figura 7 Tome dos lecturas con el nivel puesto diagonalmente en una direcci n y despu s en la otra Nivele la estufa si es necesario ajustando las 4 patas niveladoras con una llave de tuercas Figura 8 Figura 7 niveladora y Bajar Figura 8 6 Instrucciones para la Instalaci n del Soporte Antivuelco ADVERTENCIA IMPORTANTE PARA SEGURIDAD Para reducir el riesgo de que la estufa se vuelque sta debe estar asegurada al piso por medio de soportes antivuelco propiamente instaladas con los tornillos que se acompa an con la estufa Las piezas se encuentran en un saco de pl stico en el horno Si no se instalan estes soportes la estufa se volcar si se coloca peso excesivo sobre una puerta abierta o si un ni o se subiera al aparato Puede tener como resultado lesiones serias como consecuencia de derrame de l quidos calientes o por que la estufa misma puede caerse Estudie las instrucciones en esta p gina para una instalaci n apropiada Si la estufa se mueve a un lugar diferente los soportes para evitar el balanceo tambi n deben quitarse y volverse a instalar con la estufa Instrucciones para la instalaci n ver la plantilla antivuelco encuentran en un saco de pl stico en el horno A
7. no permitir que la cubierta de acceso sea cerrada en forma apropiada lo cual puede crear un riesgo el ctrico potencial si se perforan los alambres Cuando se use conduit flexible o cable para estufas use un conector flexible o cable de estufa resistente a tensiones NOTA Use solamente alambre de cobre en la conexi n al bloque terminal 4 1 Modelos que requieren Juego de Cord n para el Suministro de Energ a El utilizador es responsable de la conexi n del cable del suministro el ctrico al bloque de conexi n situado detr s del panel de acceso El electrodom stico se puede conectar a trav s de un cableado permanente cableado duro cable de cobre blindado armado o cable no met lico flexible cuando el c digo local lo permite o por medio de un kit de cable de alimentaci n Vea la gr fica en la p gina siguiente para encontrar el tama o m nimo del cable a utilizarse el listado general de la UL c digo local puede diferenciar NOTA La cocina corrediza el ctrica viene de fabrica con un agujero de di metro 1 1 8 2 9 cm come se muestra en la figura 4 Si un agujero mas largo est necesario retire la arandela de la pre cortada El riesgo de fuego o de choque el ctrico puede aparecer si usa el tama o de cable incorrecto si las instrucciones de instalaci n no son seguidas o si retira la abrazadera de releva Para casas sobre ruedas nuevas instalaciones en los veh culos de recreativos o en las lugar
8. superior de la superficie para estufar y el fondo no protegido de un gabinete de metal o VISTA madera o un m nimo de 24 cuando el fondo de metal o madera POSTERIOR del gabinete esta protegido por no menos de 14 de material LJ retardante con una hoja de acero de no menos MSG No 28 0 015 Todas las a aa de acero inoxidable 0 024 de aluminio o 0 020 de cobre 0 es el Sa la ubicaci n del espacio minimo para la parte trasera de la estufa Siga todos los requerimientos de medidas antes proporcionados para evitar da os a la propiedad peligro de incendidos potenciales o superficies y cortes de gabinetes que sean incorrectos Para eliminar el riesgo de quemaduras o incendio cuando trate de a En Ubicaci n donde se debe instalar alcanzar objetos por sobre unidades de superficie calentadas debe del bloque l tomacorriente evitarse que los gabines para almacenamiento esten localizados terminal 4 el ctrico para encima de la superficie de la estufa Si existen gabinetes de instalaci n afas delg almacenamiento el riesgo puede ser reducido instalando una campana de estufa que se proyecte en forma horizontal a una distancia m nima de 5 mas alla del fondo de los gabinetes Notas importantes para el instalador 1 Lea todas las instrucciones contenidas en este manual antes de instalar la estufa 2 Saque todo el material usado en el embalaje de la estufa antes de conectar el sum
9. 30 ELECTRIC RANGE INSTALLATION INSTRUCTIONS United States INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER Canada IMPORTANT SAVE FOR LOCAL ELECTRICAL INSPECTOR S USE U READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE A L MITAD FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance 1 Clearances and Dimensions a Provide adequate clearances between the range and adjacent combustible surfaces b Location Check location where the range will be installed Check for proper electrical supply and the stability of floor c Dimensions that are shown must be used Given dimensions provide minimum clearance Contact surface must be solid and level FRONT TYPICAL CABINET INSTALLATION SIDE VIEW MA VIEW 0 AN n 49 Minimum to An i Minimum to 13 gt wall on either EEE 1g cabinets on Maximum depth Maximum side of range either side for cabinets above 36 height of range above range top Y A A gt Ss man x 46 J Door e 3018 gt 0 clearance below cooking top and at rear of range 30 minimum clearance between the top of the cooking surface and the bottom of an unprotected wood or metal cabinet or 24 minimum when bottom of wood or metal cabinet is protected by n
10. ANGE INSTALLATION INSTRUCTIONS 2 Install Anti Tip Bracket See instructions on page 4 3 Serial Plate Information The serial plate is located as shown See the serial plate for the following information A Model lot and serial number of range B Kilowatt rating power requirements C Voltage ratings Figure 1 4 Electrical Connection Requirements This appliance must be properly installed and grounded by a qualified technician in accordance with the National Electrical Code ANSI NFPA No 70 latest edition and local electrical code requirements This appliance may be connected by means of permanent Hard Wiring or Power Supply Cord Kit When hard wiring do not leave excess wire in range compartment Excess wire in the range compartment may not allow the access cover to be replaced properly and could create a potential electrical hazard if wires become pinched When using flexible conduit or range cable use flex connector or range cable strain relief NOTE Only use copper wire in connection to terminal block 4 1 Models Requiring Power Supply Cord Kit The user is responsible for connecting the power supply cord to the connection block located behind the back panel access cover This appliance may be connected by means of permanent hard wiring flexible armored or nonmetallic shielded copper cable when local code allow it or by means of a power supply cord kit NOT
11. E Electric Slide in Range is shipped from factory with 1 1 8 2 9 cm dia hole as shown on figure 4 If a larger hole is required punch out the knockout Risk of fire or electrical shock exists if an incorrect size range cord kit is used the Installation Instructions are not followed or the strain relief bracket is discarded For mobile homes new installations or recreational vehicles use only a power supply kit designed for a range at 125V 250V 50A recommended minimum 40A Cord must have either 3 when local code permits grounding through neutral or 4 conductors Terminal on end of wires must be either closed loop or open spade lug with upturned ends Cord must have strain relief clamp If a 50A circuit is used a 50A power cord must be used Do not loosen the nuts which secure the factory installed range wiring to terminal block while connecting range Electrical failure or loss of electrical connection may occur A WARNING Electrical Shock Hazard e Electrical ground is required on this appliance Do not connect to the electrical supply until appliance is permanently grounded Disconnect power to the circuit breaker or fuse box before making the electrical connection e This appliance must be connected to a grounded metallic permanent wiring system or a grounding connector should be connected to the grounding terminal or wire lead on the appliance Failure to do any of the above could result in a fire
12. Punch Out A User Supplied Strain relief Must de Installed at This O Knockout for 1 3 8 ocation 3 5 cm Dia Cord Kit Hole Figure 3 Four Conductor Wire Connection to Range Where local codes does NOT permit connection of the frame grounding conductor to the neutral wire of the copper power supply cord see Figure 4 1 Remove the screws from the access plate at the lower right end of the rear cover to expose range terminal connection block 2 Remove the grounding strap from the terminal block and from the appliance frame 3 Using the nuts supplied with the literature package connect the ground wire green of the copper power supply cord to the frame of the appliance with the ground screw using the hole in the frame where the ground strap was removed see Figure 4 4 Connect the neutral of the copper power supply cord to the center silver colored terminal of the terminal block and connect the other wires to the outer terminals Match wires and terminals by color red wires connected to the right terminal black wires connected to the left terminal 5 Replace the terminal cover and replace the screws Silver Colored Terminal Terminal Block 1 1 8 2 9cm Dia Direct Connection Hole Punch Neutral Out Knockout White Wire for 1 3 8 3 5cm Dia Ground Bare Cord Kit Hole Copper Wire A User Supplied Strain relief Must Be Installed at This Location To 240 V Receptacle
13. SERVICIO DEBEN SER EFECTUADOS POR UN INSTALADOR CALIFICADO Canad IVIPORTANTE GUARDE ESTAS INSTRUCCIONES PARA USO DEL INSPECTOR LOCAL DE ELECTRICIDAD UL LEA Y GUARDE ESTAS INSTRUCCIONES PARA REFERENCIA FUTURA Rs PARA SU SEGURIDAD No almanece ni utilice gasolina u otros vapores y l quidos inflamables en la proximidad de este o de cualquier otro artefacto 1 Espacios y dimensiones a Proporcione espacios adecuados entre la estufa y las superficies combustibles adyacentes b Ubicaci n Examine el lugar en el cual va a ser instalada la estufa Determine la existencia de suministro el ctrico adecuado y la estabilidad del piso c Se deben usar las medidas indicadas Las dimensiones indicadas proporcionan espacio m nimo La superficie de contacto debe ser s lida y estar a nivel VISTA SIDE VISTA ara FRONTAL TYPICAL CABINET INSTALLATION yyy FRONTAL 22 7 ll A gt 30 Minimum A Minimo aioe 13 49 M nimo a la pared a cada lado de la 1 cocina o la cocina a 36 de alto gabinetes M xima distancia Maximum 18 Sobre cada entre los gabinetes 4 jt E rp lado de la yla parte superior estufa de la cocina A 25 gt a 36 gt Me 46 Puerta abre 4 30 1 8 0 clearance below cooking top and at rear of range Un m nimo de 30 de espacio entre la parte
14. es donde los c digos locales no permiten la conexi n del conductor de tierra al neutro un ensamble de suministro el ctrico de 4 conductores para estufas calificado a 125 250 voltios m nimo 50 Amperes m nimo debe de ser utilizado ver la figura 5 Si se utiliza un circuito 50A un cable el ctrico 50A debe ser utilizado NEJM No desajuste las tuercas que aseguran la conexi n de la cocina al bloque terminal cuando est instal ndola El corte o la perdida de corriente el ctrica Figura 2 Juego de cord n de 3 alambres puede ocurrir ADVERTENCIA Peligro de choque l ctrico e La conexi n a tierra es requerida para este electrodom stico No conecte al suministro el ctrico hasta que el electrodom stico este conectado a tierra de manera permanente Desconecte el suministro el ctrico hacia la caja de empalmes antes de hacer la conexi n el ctrica e Este electrodom stico debe ser conectado a un sistema de alambres permanentes met licos conectados a tierra o una puesta a tierra debe ser conectada al terminal de tierra o un emplonbado al electrodom stico El no seguir ninguna de estas instrucciones podr a causar fuego heridas personales o choques el ctricos Este electrodom stico fue fabricado con el marco aterrizado a trav s de una correa de conexi n entre el neutral de la fuente de alimentaci n y el marco Si es utilizado en los E E U U con un circuito nuevo de instalaci
15. h see Figure 8 Figure 7 aise Figure 8 6 Anti Tip Bracket Installation Instructions IMPORTANT SAFETY WARNING To reduce the risk of tipping of the range the range must be secured to the floor by properly installed anti tip bracket and screws packed with the range These parts are located in a plastic bag in the oven Failure to install the anti tip bracket will allow the range to tip over if excessive weight is placed on an open door or if a child climbs upon it Serious injury may result from spilled hot liquids or from the range itself Refer to the instructions located in the anti tip bracket package for proper bracket installation If the range is moved to a different location the anti tip bracket must also be moved and installed with the range For the bracket installation instructions refer to the anti tip bracket template shipped in the anti tip bracket package 7 Checking Operation Refer to the Use and Care Guide for operation PIERDO not touch cooktop glass or elements They may be hot enough to burn you Before You Call for Service Read the Before You Call for Service Checklist and operating instructions in your Use and Care Guide It may save you time and expense The list includes common occurrences that are not the result of defective workmanship or materials in this appliance NOTES INSTRUCCIONES PARA INSTALACION DE LA ESTUFA ELECTRICA DE 30 Estados Unidos LA INSTALACI N Y EL
16. imentaci n Alambre neutro blanco Alambres negros Alambres Caja de empalmes Alambre blanco Alambre desnudos Conductor de o verdes uni n listado UL Cable de la estufa listado CSA NOTA Asegurese de quitar la banda de puesta a tierra 1 provista Figura 5 Donde los c digos locales NO permitan conectar el conductor de puesta a tierra del electrodom stico al neutral blanco o si est conectado con un sistema a 4 alambres vea figura 6 1 Desconecte el suministro el ctrico 2 Siga las instrucciones en la p gina anterior para la conexi n del alambre de cuatro conductores a la cocina fig 4 3 En el cortacircuito la caja de fusibles o la caja de empalmes Fig 6 a Conecte el alambre blanco del cable del electrodom stico al alambre neutral blanco b Conecte los 2 alambres negros juntos c Conecte los 2 alambres rojos juntos d Conecte el alambre verde o de cobre desnudo de la puesta a tierra del alambre al alambre de puesta a tierra del cortacircuito de la caja de fusibles o de la caja de empalmes Cable de la fuente de Alambre alimentaci n desnudo o verde Alambre blanco Alambres rojos Alambres negros Alambre desnudo o verde Alambre blanco Caja de 4 Preece Conductor de empalmes uni n listado UL Cable de la o listado CSA estufa NOTA Asegurese de quitar la banda de puesta a tierra _ _
17. inistro el ctrico a la estufa 3 Observe todos los c digos y reglamentos pertinentes 4 Deje estas instrucciones con el consumidor Nota importante al consumidor Conserve estas instrucciones y el Manual del usuario para referencia futura Impreso en los Estados Unidos 318201724 0904 Rev A INSTRUCCIONES PARA INSTALACION DE LA ESTUFA ELECTRICA DE 30 2 Instale los soportes antivuelco Ver instrucciones en la p gina 4 3 Placa de Identificaci n Esta placa de identificaci n f est localizada sobre el Marco y se puede ver cuando la gaveta est abierta Consulte la placa de identificaci n para obtener la siguiente informaci n A N meros de modelo partida y serie de la estufa B Tasa de kilovatios requerimientos de energ a C Tasa de voltaje 4 Requisitos de conexi n el ctrica Este aparato debe estar instalado en forma apropiada y puesto a tierra por un t cnico calificado de acuerdo con el National Electric Code C digo Nacional de Electricidad ANSI NFPA No 70 ltima edici n y con los requerimientos de electricidad de los c digos locales Este aparato puede ser conectado por medio de una extensi n a un tomacorriente local permanente o por medio de Juego de Cord n para el Suministro de Energ a Cuando se use la extensi n no deje exceso de alambre en el compartimiento de la estufa Si se deja exceso de alambre en el compartimiento sto
18. ntes de llamar al servicio Lea la secci n Lista de Antes de llamar en su Manual del Usuario Esto le podr ahorrar tiempo y gastos Esta lista incluye ocurrencias comunes que no son el resultado de defectos de materiales o fabricaci n de este artefacto NOTAS
19. ot VIEW less than flame retardant millboard covered with not less than SSI gt no 28 MSG sheet steel 0 015 stainless steel 0 024 aluminum A 3 All dimensions for or 0 020 copper The minimum clearance is 0 for the rear of the gt pres outlet range Follow all dimension requirements provided above to prevent Kae a property damage potential fire hazard and incorrect countertop and cabinet cuts Cubed area shows Avoid locating cabinet storage space above the surface units Terminal where the electrical to eliminate the possibility of cabinets catching on fire or Block outlet must be personal burns from reaching for the cabinets over the heated Location installed for the units If cabinet storage is to be provided risk can be reduced by E range to be flush to installing a range hood that projects horizontally a minimum of the wall j 4 5 beyond the bottom of the cabinets Important Notes to the Installer 1 Read all instructions contained in these installation instructions before installing the appliance 2 Remove all packing material before connecting the electrical supply to the appliance 2 oe gr 3 Observe all governing codes and ordinances 4 Be sure to leave these instructions with the consumer Important Note to the Consumer Keep these instructions with your Use and Care Guide for future reference Printed in United States 318201724 0904 Rev A 30 ELECTRIC R
20. personal injury or electrical shock U S STYLE Figure 2 3 Wire Cord Kit This appliance is manufactured with the frame grounded by connection of a grounding strap between the neutral power supply terminal and the frame If used in USA in a new branch circuit installation 1996 NEC mobile home or recreational vehicule where local code do not permit grounding through neutral white wire or in Canada remove the grounding strap from the frame and cut the other end near the neutral terminal Connect the appliance in usual manner 30 ELECTRIC RANGE INSTALLATION INSTRUCTIONS Three Conductor Wire Connection to Range If local codes permit connection of the frame grounding conductor to the neutral wire of the copper power supply cord see Figure 3 1 Remove the screws from the access plate at the lower right end of the rear cover to expose range terminal connection block 2 Using the nuts supplied in the literature package connect he neutral of the copper power supply cord to the center silver colored terminal of the terminal block and connect he other wires to the outer terminals Match wires and erminals by color red wires connected to the right erminal black wires connected to the left terminal see igure 3 3 Replace the terminal cover and replace the screws Silver Colored Terminal Terminal Block White Wire Grounding 1 1 8 2 9 cm Dia Direct Connection Hole
Download Pdf Manuals
Related Search
Related Contents
Philips CD4801B AMX UDM-0404 User's Manual Page 1 of 3 X`Trem Tour: l`incroyable défi de Pascal Pich AutoDAB-GO 1219 NUTRITION Scale OPERATING INSTRUCTIONS manual de instalação de academia ao ar livre Amana WS900E Installation Guide B. CLASIFICACIDN DE LAS ZANJAOORAS , J 屋外用BS手すりEX 取扱説明書2 Model (1) Copyright © All rights reserved.