Home

Emerson NET 1080T Surge Protector User Manual

image

Contents

1. Liebert is a registered trademark of Liebert Corporation Outside U S 614 841 6755 PO Box 29186 EM ERSO ane ATEO O AE TACEMANE OETEJISIETEN upstech emersonnetworkpower com Columbus OH 43229 trademarks of their respective owners F 10 22002_REV0_07 08 Web site www liebert com
2. Liebert PSS Surge Suppressor Quick Start Guide Models PRF 1080 NET 1080T IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions that should be followed during installation and maintenance of the Liebert PSS surge suppressor e Intended for installation in a controlled environment e Maximum ambient temperature 104 F 40 C CAUTION A To reduce the risk of fire connect only to a circuit provided with 15 amperes maximum branch circuit EMERSON Network Power Locate the surge suppressor near a wall outlet Do not use an extension cord between the surge suppressor and the outlet The Liebert PSS has been designed for small office home office use only it is NOT recommended for use in life support applications In the event of an emergency press the OFF button and disconnect the power cord from the AC power supply to properly disable the surge suppressor Do not attach power strips or other surge suppressors to the Liebert PSS surge suppressor overcurrent protection in accordance with the national code ANSI NFPA 70 e Do not connect equipment that may overload the surge suppressor or demand half wave rectification such asa laser printer e Connect the surge suppressor only to an earthed grounded outlet that meets national and local electrical safety guidelines e Do not attempt to service any parts inside the surge sup pressor Failure to adhere to
3. en damaged Please contact your supplier for any warranty return repair instructions The green SURGE PROTECTION indicator does not illuminate when powered ON Try plugging the Liebert PSS into a different wall receptacle e Ifthe indicator illuminates the Liebert PSS is operating properly and the first wall receptacle needs repair Please contact an electrician to repair the faulty receptacle If the indicator does NOT illuminate in a different receptacle e The Liebert PSS may have been overloaded and the internal circuit breaker may have tripped Remove all loads from device and reset the circuit breaker by pushing the button back in Replace loads one at a time The Liebert PSS may have been damaged Please contact your supplier for any warranty return repair instructions SPECIFICATIONS AC Power Protection Nominal Operating Voltage 120V O Ora Maximum Operating Voltage 130V Rated Output Mode of Protection Peak Surge Rating Surge Energy EMI RFI Filtration UL 1449 Surge Voltage Rating Network Protection Connection Type Protection r S SS LiebertP gt RSON surge Prov EME power pIBLE ALARM A PROTECTION SURGE 15A L N L G N G 72 000A 1080 Joules Yes 330V GROUND RJ45 2008 Liebert Corporation All rights reserved throughout the Technical Support Service United States world Specifications subject to change without notice 800 222 5877 1050 Dearborn Drive
4. tal contact with electrical light and or power conductors e Connect the other end of the patch cord to the original wall or modem outlet FEATURES Indicators Each Liebert PSS has a visual SURGE PROTECTION indicator that illuminates green to show that the surge suppressor is functioning properly Wall Mounting If wall mounting is desired two keyed slots are provided and located on the back of the surge suppressor The Liebert PSS also has an audible alarm to alert you if the suppression fails Surge suppressors are often hidden from view behind furniture and other objects that prevent you from seeing the visual indicator Wall Mounting Detail ae ae Rear View 5 50 TROUBLESHOOTING If the Liebert PSS malfunctions during operation check the following chart for proper adjustment For further assistance please contact your local Emerson Network Power representative Recommended Actions The green Try plugging the Liebert PSS into a different wall receptacle GROUND e Ifthe indicator illuminates the Liebert PSS is operating properly and the first wall receptacle needs repair Please indicator contact an electrician to repair the faulty receptacle stat la If the indicator does NOT illuminate in a different receptacle e Your building wiring might not contain a ground conductor In this case the indicator light will not illuminate but you will still have power out of the Liebert PSS e The Liebert PSS may have be
5. this could cause personal injury or equipment malfunction and void the warranty For technical support e Visit www liebert com or e Send an e mail to upstech emersonnetworkpower com SETUP Congratulations on purchasing the Liebert PSS Surge Suppressor The Liebert PSS is designed to protect 120 Volt electronic equipment The surge suppressor is capable of carrying up to 15A current Follow these instructions to ensure that your Liebert PSS surge suppressor is properly installed and functioning Step 1 Connect AC Equipment to the Liebert PSS Models PRF 1080 and NET 1080T e Plug the surge suppressor into a grounded outlet only e Plug the cords from your computer home entertainment or other electrical equipment into the surge suppressor s receptacles e For large transformer blocks use one of the three dedicated outlets on your surge suppressor Step 3 Apply Power to the Liebert PSS Models PRF 1080 and NET 1080T e Turn the power switch to the ON position Step 2 Connect Network Electronics Model NET 1080T only e Disconnect the end of your network line at the wall or modem end e Connect it to one of the OUTPUT connections on the A CAUTION NET 1080T This protector is intended for indoor use on l communication loop circuits which have been j ee ae cord to the INPUT connection on the isolated from the Public Switched Telephone Network The communication loop circuits shall not be exposed to acciden

Download Pdf Manuals

image

Related Search

Related Contents

TSP 5.0 Reference Manual - National Bureau of Economic Research  HP LaserJet M4345 Multifunction Printer  Fisher-Price BARBIE SONGBIRD 76922 User's Manual  PROFISHARK 1G - Batter Fly S.r.l.  MC―1000/MC-6100  Sony KV-14CT1B User's Manual  REF 30 192 VIDAS® H. pylori IgG (HPY)  Fisher-Price M9970 Instruction Sheet  Targus AWV1230EU screen protector  

Copyright © All rights reserved.
Failed to retrieve file