1. 5 600 5111 Fax 01489 773053 e mail customer services glendimplex com Tel 01 8424833 All rights reserved Material contained in this publication may not be reproduced in whole or in part without prior permission in writing of Glen Dimplex UK Limited
2. IANCE THIS MAY IMPAIR THE SELF RIGHT FUNCTION NEVER leave the heater unattended when it is used by or near the aged infirm person s or children THE HEATER CARRIES THE WARNING SYMBOL INDICATING THAT IT MUST NOT BE COVERED The instruction leaflet belongs to the appliance and must be kept in a safe place If changing owners the leaflet must be surrendered to the new owner IMPORTANT If the mains lead of this appliance is damaged it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard WARNING In order to avoid a hazard due to inadvertent resetting of the thermal cut out this appliance must not be supplied through an external switching device such as a timer or connected to a circuit that is regularly switched on and off by the utility Electrical connection This heater must be used on an A C supply only and the voltage marked on the heater must correspond to the supply voltage This heater is fitted with a plug incorporating a 13 amp fuse When replacing the fuse a 13 amp fuse approved by ASTA to BS 1362 must be used If the plug is not suitable for the socket outlets in your home the plug must be cut off and an appropriate one fitted A plug cut off from a mains lead will give a shock hazard if inserted into a 13 amp socket elsewhere in the house To avoid this it should be disposed of immediately NOTE The fuse cover of a non rewirable plug must be refitt
3. ed when changing the fuse Should the cover become lost the plug must not be used until the correct replacement fuse cover is obtained from your supplier or by contacting our customer helpline IMPORTANT The wires in this mains lead are coloured in accordance with the following code BLUE NEUTRAL BROWN LIVE As the colours of the wires in the mains lead may not correspond with the coloured markings in your plug proceed as follows Connect the BROWN wire to the terminal marked L or coloured RED Connect the BLUE wire to the terminal marked N or coloured BLACK Note L or N must not be connected to the EARTH terminal marked Eor amp orcoloured GREEN or GREEN AND YELLOW If in doubt consult your electrician Using the Heater Heat Control see Fig 2 i OFF Cool Blow Half heat Full heat Fig 2 Thermostat Control see Fig 3 The heat output is controlled by the thermostat according to the room temperature Turn the thermostat knob fully clockwise to maximum setting initially When the room is warm enough reduce the setting slowly until the heater just clicks off Fig 3 The heater will now cycle on and off to maintain your selected room temperature An audible click may be heard when the thermostat operates this is normal Note If the heater does not come on when the thermostat is at a low setting this is normally because the room is warmer than the thermostat settin
4. g and is not a fault When the heat control is set to 3g for cool blow set the thermostat control to maximum Position will turn the heater on and off to maintain a temperature of approximately 5 C Safety overheat protection For your safety this appliance is fitted with a thermal cut out In the event that the product overheats the cut out switches the heater off automatically To bring the heater back into operation remove the cause of overheating then turn off the electrical supply to the heater for a few minutes When the heater has cooled sufficiently reconnect and switch on the heater If the cut out operates repeatedly contact your supplier Cleaning WARNING ALWAYS DISCONNECT FROM THE POWER SUPPLY BEFORE CLEANING THE HEATER Do not use detergents abrasive cleaning powders or polish of any kind on the heater Wipe with a dry cloth to remove dust and a damp cloth not wet to clean off stains Be careful not to allow moisture into the heater Ensure that dust or fluff does not accumulate inside the heater as this could lead to overheating of the element Use a vacuum cleaner to remove any fluff which does accumulate Recycling For electrical products sold within the European Community At the end of the electrical products useful life it should not be disposed of with household waste Please recycle where facilities exist Check with your Local Authority or retailer for recycling advice in your coun
5. try After Sales Service Your product is guaranteed for three years from the date of purchase Within this period we undertake to repair or exchange this product free of charge provided it has been installed and operated in accordance with these instructions Your rights under this guarantee are additional to your statutory rights which in turn are not affected by this guarantee Should you require after sales service you should contact our customer services help desk on 0845 600 5111 It would assist us if you can quote the model number series date of purchase and nature of the fault at the time of your call The customer services help desk will also be able to advise you should you need to purchase any spares Please do not return a faulty product to us in the first instance as this may result in loss or damage and delay in providing you with a satisfactory service Please retain your receipt as proof of purchase C The product complies with the European Safety Standards EN60335 2 30 and the European Standard Electromagnetic Compatibility EMC EN55014 EN60555 2 and EN60555 3 which cover the essential requirements of EEC Directives 73 23 and 89 336 Glen Dimplex UK Limited Millbrook House Grange Drive Hedge End Southampton Hampshire SO30 2DF c Glen Dimplex UK Limited Customer Services Republic of Ireland UK customer help line 8 00am 5 00pm Mon Fri and 8 30am 1 00pm Sat Autumn Winter only Tel 084
6. xX Dimplex Installation and Operating Instructions 5N 08 35169 0 Issue 0 JX BEAB IP21 Model s DXUFSR2 TIPSY Fan Heater eM Dimensions H W see Fig 3 millimetres 265 230 230 cE see Fig 2 Model s Specification DXUFSR2 2 0kW Thermostat amp Switch Fig 1 IMPORTANT THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE IMPORTANT SAFETY ADVICE DO NOT use the heater on deep pile carpets or the long hair type of rugs or less than 750mm 30 away from any overhanging surface Keep combustible materials such as drapes and other furnishings clear from the front sides and rear of the heater Do not use heater to dry your laundry DO NOT use the heater in the immediate surroundings of a bath a shower or a swimming pool DO NOT place the heater directly below a fixed socket outlet The socket outlet must be accessible at all times to enable the mains plug to be disconnected as quickly as possible DO NOT COVER or obstruct the air inlet and outlet openings in any way The heater must be on a flat stable surface when in use DO NOT operate the heater with the mains lead overhanging the front outlet grille The appliance is designed to self right itself if it is accidentally knocked over however the appliance should not be maltreated to perform this function ALWAYS ENSURE THE APPLIANCE DOES NOT COME TO REST ON THE MAINS LEAD OR ALLOW THE LEAD TO BECOME WRAPPED AROUND THE APPL