1. INSTALLATION INSTRUCTIONS Automated Vertical Panel Lift This device complies with part 15 of the FCC rules Operation is subject to the following 2 conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation This equipment has been tested and found to comply with the limits of a Class B digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio or television communications However there is no guarantee that the interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment to an outlet on a circuit other than that to which the receiver is connected Consult the dealer or and experienced radio TV technician for help GCHIEF MSP CM6HABV71 83 MSP CM6HABV71 83 Installation Instr
2. Front of Motor Box Control Input Status Trigger Control Input Activator Figure 14 NOTE Making a momentary dry contact closure between the common and the open closed stop or sequence will activate the system in that mode Control Input on Front of Motor Box 1 Close 2 Common 3 Sequence Control Open Stop Close Stop 4 24V DC for Powering Radio Figure 15 12 Installation Instructions MSP CM6HABV7 1 83 13 MSP CM6HABV7 1 83 Installation Instructions CHIEF 8820 000025 2007 Chief Manufacturing www chiefmfg com 05 07 USA International Europe Asia Pacific 8401 Eagle Creek Parkway Savage MN 55378 800 582 6480 952 894 6280 877 894 6918 952 894 6918 Fellenoord 130 5611 ZB EINDHOVEN The Netherlands 31 0 40 2668620 31 0 40 2668615 Room 301 Block Lily YinDu International Building LuoGang BuJi Town Shenzhen CHINA Post Code 518112 WRI th HEF 6 AGRE BRA BDO 86 755 8996 9226 8996 9236 8996 9220 86 755 8996 9217
3. ABV71 83 Installation Instructions 8 Ifthe panel seems light add weight to it If the panel seems heavy add weight to the counterweights Figure 8 10 Installation Instructions MSP CM6HABV7 1 83 RF Receiver Installation Install RF reciever following the instructions provided with the receiver System Activation 1 Insert plug from the power supply into the jack on the top of the motor box Top of Cabine Front of Cabinet Figure 9 2 Plug Powercord into 115VAC outlet IMPORTANT A quality surge protection device is recommended 3 Make sure nothing is obstructing movement of doors 4 Press and release the Activator Button on the front of the Motor Box or the Close Door button on the Remote Control The doors should travel to the fully closed position Activator Status Trigger O C Figure 10 5 Press the Open Door button on the Remote Control NOTE The mechanism has been preset to travel 34 inches If a different travel distance is required see Door Travel Adjustment below ADJUSTMENTS Adjust Door Travel Distance To adjust door travel distance 1 Setthe length of travel required using the adjustable stop on the bottom of the left hand track 2 Press and hold the activator button on the front of the motor box for 13 seconds The Status Light on the front of the motor box will beg
4. OF POWER CORD MUST REMAIN ACCESSIBLE AT ALL TIMES DO NOT block or impede access to plug at any time A CAUTION Changes or modifications to this unit not expressly approved by the manufacturer can void the units FCC compliance rating and make the unit illegal to operate Installation Instructions MSP CM6HABV71 83 ASSEMBLY 1 Attach cables to weights by hand and tighten retaining nut using a 7 16 wrench Figure 1 MSP CM6HABV71 83 Installation Instructions INSTALLATION 1 Screw tracks to cabinet using 1 8 masonite space provides screw head clearence for double wall Figure 2 Installation Instructions MSP CM6HABV71 83 2 Level cabinet in both directions Figure 3 MSP CM6HABV7 1 83 Installation Instructions 3 Attach door plates 1 inch down from the top with the V notch aligned with the panel edge Figure 4 Installation Instructions MSP CM6HABV71 83 4 Gently push to make sure that wheels are touching track Figure 5 MSP CM6HABV71 83 Installation Instructions 5 Remove nuts from the studs on the wheel plates and place the panel on the mechanism 6 Center the panel and tighten the nuts Figure 6 Installation Instructions MSP CM6HABV71 83 7 While holding back the chain attachment bracket move the door up and down to check for balance Also check to see if the counterweights hit or rub the cabinet If it does it s not level Figure 7 MSP CM6H
5. followed by a pause Similar to Doors Obstructed but doors are prevented from moving in either direction Remove the obstruction and then activate the doors They should return to normal run motion Travel Too Far The Status Light will flash in groups of 5 red followed by a pause The motor is running but the doors are not moving Has the motor box been uncoupled from the track or is the motor box bent causing it to become uncoupled from the track Open 8 Stop 7 IR reciver Input 6 IR reciver Input 5 Power Loss The Status Light will be on solid red There has been a power loss due to an electrical storm etc When next activated the doors will move at a slow speed to their full closed position If the doors are already closed they will not move The Status Light will return to solid green and the doors are ready for normal activation Optional Control Input Connections Control Input 8 position RJ 45 modular phone jack Discrete control for use with 3rd party control e Position 8 Open e Position 7 Stop IR Receiver Eye input for Eubank Inc supplied external IR reciever only e Position 6 V out e Position 5 Vcc 5v Radio Power for external RF reciever only e Position 4 24 VDC Sequence control for use with 3rd party control e Position 3 Sequence Open Stop Close Stop e Position 2 Common Discrete control for use with 3rd party control e Position 1 Close Control Input on
6. in to blink alternately red and green When this starts to happen release the Activator Button When put into Learn Moden the system runs back and forth several times and measures it s environment such as open and closed locations etc The system will then stop and remember these learned measurements Activator Status Trigger Control Input Activator O Figure 11 System Controls and Indicators Learn Mode The CM6SV system has no limit switches The system uses an encoder on the motor to collect data and send it to the micro processor s memory The software learns about its environment speed time duration stop points etc during the initial setup of the unit and retains that information until requested to relearn its environment The unit is shipped pre set from the factory and will then continually adjusts to its enviornment on each activation If for some reason you want to place the system into Learn Mode such as to stop at other than its normal stop points Press and hold the red activator button on the front of the motor box for approxamatly 13 seconds and then release it when the Status Light flashes quickly red green red green red green Activator Button Status Trigger Control InpuX Activator L Figure 12 The controller will then be in Learn Mode The door will move for 3 seconds stop f
7. or 10 seconds and when it starts moving again it will be in it s Learn Mode When put into Learn Mode the mechanism runs back and forth several times and measures it s environment such as open and closed locations etc and then stops and remembers 11 MSP CM6HABV7 1 83 Installation Instructions these learned measurements so that next time the system runs it knows where to start and stop Status Light Codes There is a light on the front of the mechanism motor box that will tell through its pattern of flashes and colors what the mechanism is doing Status Indicator ve Control Input Activator o 1 Figure 13 Normal Doors At Rest The Status Light will be on steady green Normal Run Motion of Doors The Status Light will flash in groups of 2 green followed by a pause In normal run motion the doors on a Eubank mechanism have a variable speed The doors will start slowly accelerate to a fast speed and then slow down before coming to a stop Doors Obstructed The Status Light will flash in groups of 3 red followed by a pause If the doors meet an obstruction they will sense the obstruction stop momentarily and move in the opposite direction for a few seconds Remove the obstruction and then activate the doors They should return to normal run motion Doors Obstructed Both Ways The Status Light will flash in groups of 4 red
8. ponsibility to make sure all components are properly assembled and installed using the instructions provided Read all instructions before using this furnishing A DANGER TO REDUCE THE RISK OF ELECTRIC SHOCK e ALWAYS unplug this furnishing from the electrical outlet before cleaning WARNING TO REDUCE THE RISK OF BURNS FIRE ELECTRIC SHOCK OR INJURY TO PERSONS Unplug from outlet before putting on or taking off parts Close supervision is necessary when this furnishing is being used by or near children invalids or disabled persons Use this furnishing only for its intended use as directed in these instructions DO NOT use attachments not recommended by the manufacturer NEVER operate this furnishing if it has a damaged cord or plug if it is not working properly if it has been dropped or damaged or dropped into water Return the furnishing to a service center for examination and repair Keep the cord away from heated surfaces NEVER operate the furnishing with the air openings blocked Keep the air openings free of lint and the like NEVER drop or insert anything into any opening DO NOT use outdoors DO NOT operate where aerosol spray products are being used or where oxygen is being administered e To disconnect turn all controls to the off position then remove plug from outlet WARNING RISK OF ELECTRICAL SHOCK Connect this device to a properly grounded outlet only A CAUTION ONE END
9. uctions CSAV Inc and its affiliated corporations and subsidiaries collectively CSAV intend to make this manual accurate and complete However CSAV makes no claim that the information contained herein covers all details conditions or variations nor does it provide for every possible contingency in connection with the installation or use of this product The information contained in this document is subject to change without notice or obligation of any kind CSAV makes no representation of warranty expressed or implied regarding the information contained herein CSAV assumes no responsibility for accuracy completeness or sufficiency of the information contained in this document A IMPORTANT WARNINGS AND CAUTIONS The Alert messages DANGER WARNING CAUTION IMPORTANT and NOTE are used throughout these instructions and on the product to alert the reader and or operator of the existence of dangerous situations conditions and or important operational and maintenance information SAVE THESE INSTRUCTIONS WARNING WARNING alerts you to the possibility of serious injury or death if you do not follow the instructions A CAUTION A CAUTION alerts you to the possibility of damage or destruction of equipment if you do not follow the corresponding instructions WARNING FAILURE TO READ AND FOLLOW THE FOLLOWING INSTRUCTIONS CAN RESULT IN SERIOUS PERSONAL INJURY DAMAGE TO EQUIPMENT OR VOIDING OF FACTORY WARRANTY It is the installers res