Home
MIO-CARE PRO - I-Tech Medical Division
Contents
1. Free memories NEMS Total time 1 90 min frequency 1 200 Hz contraction time 1 10 sec slope 0 5 sec recovery time 0 30 sec width impulse 50 450ps 6 10 Free memories NEMS alternated Total time 1 90 min frequency 1 200 Hz contraction time 1 10 sec slope 0 5 sec recovery time 0 30 sec width impulse 50 4505 11 12 M13 Battery test IACER S r l 27 of 36 MNPG148 Rev 02 02 07 15 I TEGR MEDICAL DIVISION 1 5 TENS Free memories Free memories for antalgic TENS treatment 6 10 NEMS Free memories Free memories for muscle recovery and training 11 12 NEMS Alternated free memories Free memories for muscle recovery and or training with alternated impulses on channel 1 and 2 M13 Battery test program only for I A C E R assistance centre Program for battery test Maintenance Battery charging Display will show low battery indicator c1 only when battery is low In this case it may not be possible to undertake the therapy session or not being able to complete it To proceed with the charging follow the steps below Make sure that the device is switched off or switch off the device pressing the O OK button Connect the battery charger to the plug of the unit and connect the battery charger into the power socket The display will show the battery blinking icon After 4 hours the recharge automatically finishes and the display shows the recharge total time
2. 48x48mm packages containing 4 pre gelled self adhesive 40x80 mm electrodes or 50x90mm belt clip carriage bag user manual n 1 electrodes position manual b_D Db 5 Db D DDD How to use Warnings Take cate of position and meaning of the labels on PRO 0 Do not damage the connection cables and avoid to roll up the cables around the device Check the device and its accessories before use Avoid the use in case of damage to the case or to the accessories damaged cables contact the manufacturer as mentioned in Assistance paragraph 0 Avoid the use of MIO CARE PRO to people not educated through the reading of the manual Avoid the use of MIO CARE PRO in damp environments Do not wear metallic objects during therapy It is forbidden to position the electrodes in such a way that the current crosses the heart area e g a black electrode on the chest and a red electrode on the shoulder blade e Use of the device is prohibited with electrodes positioned on or close to injuries or cuts The electrodes must not be positioned on the carotid sinuses carotid or genitals The electrodes must not be positioned close to the eyes make sure that the current delivered does not cross the eyeball one electrode diametrically opposite to the other in relation to the eye keep a distance of at least 3 cm from the eyeball Insufficiently sized electrod
3. Total time 10 min 3Hz 200us x 7sec 80 1Hz fre 7 6 Hz c 9 0 1 requency 6 Hz soa m sec oo Vo 200ps x 3 sec 100 30Hz impulse width 2001s 2 40 cycles 60 cycles Total time 4 min Totaltiine DE ria 300 x 7sec 80 1Hz n B2 frequency 6 Hz 300ps x 3 sec 100 Si a 0 O0us x 3 sec 100 30Hz impulse width 300us a 80 x 300us x 5 sec 80 x 40 cycles 60 cycles Total time 4 min Total time done ae ala e 200ps x 7 80 1Hz frequency 6 Hz 200ps 3 sec 100 e 200 x 3 sec 100 50Hz impulse width 2001s SE 200 5 sec 75 40 cycles 60 cycles Total time 4 min Total Seli ota time GHz 300 x 7sec 80 1Hz 7 B4 frequency 6 Hz 300us x 3 sec 100 4 ii 300ps x 3 sec 100 50Hz impulse width 300ps E ORA OSEE 300 x 5 sec 75 x 40 cycles 60 cycles Total t 4 mi Total time 10 min 3Hz Total ti 5 min 5 2 200 ime min 5 Z 200 7sec 80 1Hz E p 2 Pes 2 5 frequency 6 Hz 200 x 3 sec 100 2 1 I 5 sec 0 z 200ps impulse width 2001s 60Hz 200ps x 5 sec 70 sec 70 x 20 cycles 40 cycles Total t 4 mi Total time 10 min 3Hz Total ti 5 min 3Hz 300 81881 min SEE 300ps x 7sec 80 1Hz A i v i 50 B6 frequency 6 Hz 300ps x 3 sec 100 aay i o 7 sec 0 z 300us x 5 impulse width 300 Sa UNIS Seo sec 75 x 20 cycles 40 cycle
4. Resistan a o 3 upper limbs 32222220 3 Free TENS 3 values lower limbs and trunk Tonine Resistant 4 Anti inflammatory 4 cum 4 strength upper 4 Free TENS 4 s lower limbs limbs and trunk Neck Definition Resistant 5 2 5 upper limbs 5 strength lower 5 Free TENS 5 pain headache and trunk limbs Backache sciatic Definition Pu strength E Free NEMS 6 5 6 6 upperlimbs and 6 pain lower limbs 1 trunk 1 noth free N IQ 7 Sprains bruises 7 Modelling 7 Basic strength 7 Eee NEMS lower limbs 2 Fast strength aa 8 Vascularization 8 Microlifting 8 upperlimbs and 8 E ENS trunk i 7616 Fas re s tree d 9 Muscle selax rit 9 Lipolysis 9 ast strength 9 Free NEMS abdomen lower limbs 4 1 1 Explosive Hand and wrist Lipolysis Free NEMS 0 0 0 strength upper 0 pam thighs limbs and trunk 5 Explosive Lipolysis Alternated 1 Plantar stimulation 1 glutei and hips 1 e lower 1 NEMS 1 Lipolysis Deep Alternated 2 a arms capillarization NEMS 2 3 Epitroclea 3 Tissue elasticity 3 Muscle recovery 3 Battery test 4 Periarthritis 4 Capillarization q4 Agonist antagonist Sequential tonic 5 Heaviness in contractions legs x upper limbs and trunk Sequential tonic 6 contractions lower limbs IACER S r l MNPG148 Rev 02 02 07 15 11 of 36 I TEGN Sequential phasic contractions upper
5. At the end of battery charging disconnect the charger from power supply and store it in the carriage bag Battery replacement To proceed with battery replacement follow the steps below Remove the clip belt e battery compartment e Disconnectthe cable and take away the battery e Connect the cable of the new battery e Close the battery compartment and insert the belt clip It is recommended to remove the battery in case of prolonged inactivity Batteries have to be handled by adult persons keep them out of children s reach Dispose the battery according to the current regulations ATTENTION the life of the battery depends on the number of charge recharge cycles We suggest the following precautions for a battery longer duration Recharge the battery once month even if the device is not used e Discharge the battery as much as possible before the recharging IACER S r l 28 of 36 MNPG148 Rev 02 02 07 15 e Use only the original battery charger or in any case the battery charger supplied by the fabricant distributor Not open or modify the battery charger Cleaning Clean the equipment from the dust using a soft cloth Resistant stains can be removed using a sponge soaked in solution of water and alcohol Device not subjected to sterilization Carriage and storage Carriage precautions MIO CARE PRO is a portable device so it does not need any particular carriage precautions However we rec
6. Epitroclea Also known as golfing elbow it affects golfers but also those who carry out repetitive tasks or tasks involving frequent intense strain for example carrying a particularly heavy suitcase It causes pain in the flexor and pronator tendons inserted in the epitroclea Pain is felt when bending or straightening the wtist against resistance or when clenching a hard rubber ball in the hand 15 applications once a day even twice until the symptoms pass We tecommend that you consult your doctor to identify the precise cause of the pain in order to prevent the condition from reoccurring Program duration 40 minutes intensity set above the threshold of perception Position of electrodes photo 29 but with all of the electrodes positioned on the inside of the arm with a rotation of about 90 TENS 14 Periarthritis Scapulo humeral periarthritis is an inflammatory condition affecting the fibrous tissues surrounding joints tendons serous sacs and connective tissue These appear altered and can break into fragments and calcify If neglected this condition can become heavily crippling For this reason after carrying out a cycle of 15 20 applications once a day we recommend that you consult your doctor for a cycle of specific rehabilitation exercises to reduce the pain The Tens17 program consists of various phases including Tens and muscle stimulation aimed at improving the tone of the muscles surrounding the joint IACER S
7. Hz impulse width 60 impulse width 150 impulse width 50us IACER S r l 12 of 36 MNPG148 Rev 02 02 07 15 I TECH MEDICAL DIVISION Total time 20 min Total time 10 min Total time 10 min T12 frequency 90 Hz frequency 70 Hz frequency 50 Hz impulse width 50us impulse width 60 impulse width 901s Total time 20 min Total time 20 min T13 frequency 90 Hz frequency 70 Hz impulse width 50us impulse width 60us Total time 1 min Total time 30 min Total time 10 min frequency 150 Hz Frequency 90 Hz 3Hz 200ps x 7sec T14 impulse width 200us impulse width 60us 50 1Hz 200ps x 3 sec 60 30Hz 200uUs x 5 sec 50 x 40 cycles TENS 1 Conventional TENS Program used for analgesic purposes its purpose is to induce the organism into blocking pain at the spine in accordance with the Gate Control Theory by Melzack and Wall Pain impulses leave part of the body for example the hand and run along the nerve tracts through small diameter nerve fibres until they reach the central nervous system where the impulses are interpreted as pain Conventional tens activates large diameter nerve fibres blocking the path of small diameter nerve fibres at the spine So action is mainly taken against the symptom to simplify it further the wire transmitting pain information is obstructed Treatment duration should be no less than 30 40 minutes Conventional tens is a current that can be used to treat general everyday
8. TECH MEDICAL DIVISION NEMS 8 9 Fast strength upper limbs and trunk 8 lower limbs 9 This program is designed to increase speed in fast athletes and develop it in athletes lacking the quality Program duration 24 minutes The exercise assumes a fast pace and the contraction is short as is the recovery It is usually best to complete a three week basic strength cycle of increasing intensity before using this program Then continue with three weeks of fast strength three times a week at high intensity almost past endurance during the contraction NEMS 10 11 Explosive strength upper limbs and trunk 10 lower limbs 11 Explosive strength programs increase the explosive power and speed of the muscle mass with extremely short strengthening contractions and very long active recovery times to allow the muscle to regain strength Program duration 24 minutes It is usually best to complete a three week basic strength cycle fitness 6 7 before using this program Then continue with three weeks of explosive strength twice a week During the contraction the intensity must be the highest that can be endured in order to obtain maximum muscle exertion whilst involving the greatest number of fibres NEMS 12 Deep capillarization This program significantly increases arterial flow in the area treated Prolonged use of this program develops the intramuscular capillary network of fast twitch fibres The effect obtained is an increase in th
9. and muscular dystrophy bruises sprains neuralgias benign lesions and muscular tears tendinitis Thanks to its TENS protocols MIO CARE PRO is particularly indicated for pain therapy TENS impulses reduce significantly and eliminate the pain sensation caused by the pathologies above mentioned MIO CARE PRO is provided also with NEMS protocols for muscle rehabilitation and training for trauma and muscle tropism recovery BEAUTY protocols are indicated for modelling firming up and muscle toning up with aesthetic purposes Technical features Power supply Rechargeable batteries 4 8V 800mAh Charger Input 100 240VAC 50 60Hz 0 2A output 6 8VDC 0 3A Insulation class CEI EN 60601 1 Applied part CEI EN 60601 1 BF Dimensions length x width x 140x70x30 height mm Max output current 99mA 1K load each channel for all programs Waveform Biphasic compensated square wave Frequency Hz From 0 25 to 200 Width impulse ps From 20 to 450 Timer From 1 to 90 minutes WARNING The equipment delivers current in excess of 10 mA IACER S r l 5 of 36 MNPG148 Rev 02 02 07 15 I TECH Labels oo OOO0 1 CH1 output 2 CH2 output 3 Battery charger connector 4 Display 5 Increase intensity CH1 6 Decrease intensity CH1 Mode operation button 8 Increase intensity CH2 9 Decrease intensity CH2 0 Increase program 1 Decrease program 2 ON OFF and OK
10. button 3 Set programs and therapy pause button 4 Belt clip 5 Battery compartment IACER S r l 6 of 36 MNPG148 Rev 02 02 07 15 I TEGN OO 5 1 Mode operation NEMS TENS BEAUTY MEM 2 Wave frequency 3 Wave impulse width 4 Program number 5 CHI intensity 6 CH2 intensity 7 Battery status 8 Therapy time 9 Contraction time 10 Recovery time 11 Up down slope Labels detail A Model MIO CARE PRO I TECH S 000001 MEDICAL DIVISION Power supply Ni MH rechargeable battery 4 8V 800mAh Output voltage 0 99V at 1000 Ohm load I A C E R Srl Via S Pertini 24 A Martellago VE ITALY CEST IACER S r l 7 of 36 MNPG148 Rev 02 02 07 15 I TECH MEDICAL DIVISION Symbols description Keep dry Avoid liquid contact Product subject to WEEE regulations concerning separate waste collection of electronic ene equipment Refers to operating instructions 4 Internally powered device with type BF applied parts C Produced in compliance with the 93 42 EEC and following modifications Manufacturing date month year Kit contents MIO CARE PRO device battery pack 2 two connection cables for the transmission of electric impulses 4 two splitting leads for doubling the area covered by the electrodes packages containing 4 pre gelled self adhesive 41x41 mm electrodes
11. limbs and trunk Sequential phasic contractions lower limbs Muscle relaxant Deep massage EMS Programs Technical Specifications TENS programs Prg PHASE 1 PHASE 2 PHASE 3 Total time 40 min Tl frequency 90 Hz impulse width 50 Total time 30 min T2 frequency 1 Hz impulse width 200 Total time 3 min T3 frequency 150 Hz impulse width 200us Total time 30 min T4 frequency 120 Hz impulse width 50us Total time 20 min T5 frequency 90 Hz impulse width 60us Total time 5 min frequency 2 Hz impulse width 150ys Total time 10 min frequency 90 Hz impulse width 60us Total time 20 min Total time 20 min T6 frequency 90 Hz frequency 60 Hz impulse width 50us impulse width 60us Total time 10 min Total time 10 min Total time 10 min T7 frequency 110 Hz frequency 90 Hz frequency 70 Hz impulse width 50 impulse width 50us impulse width 60ps Total time 20 min T8 frequency 2 Hz impulse width 200 Total time 10 min Total time 10 min Total time 10 min T9 frequency 4 Hz frequency 6 Hz frequency 2 Hz impulse width 250 impulse width 200 impulse width 300 Total time 15 min Total time 15 min Total time 10 min T10 frequency 70 Hz frequency 90 Hz frequency 110 Hz impulse width 60 impulse width 50p1s impulse width 50 Total time 15 min Total time 15 min Total time 10 min T11 frequency 70 Hz frequency 2 Hz frequency 90
12. maximum values Very short duration 3 minutes Blocks pain impulses peripherally creating a proper anaesthetising effect in the area treated This type of stimulation is suitable for injuries or bruises when rapid action is required The intensity selected is the maximum tolerable value well in excess of conventional tens and therefore with considerable contraction of the muscles surrounding the area treated That is the reason why such stimulation is undoubtedly the least tolerated but is extremely effective This type of IACER S r l 13 of 36 MNPG148 Rev 02 02 07 15 TECH stimulation is not recommended for particularly sensitive people and in any case the electrodes should not be positioned in sensitive areas such as the face and genitals or close to wounds Position of electrodes form a square above the painful area as shown in illustration 1 TENS 4 Anti inflammatory Program recommended for inflammatory conditions To be applied until the inflammatory state is lessened 10 15 applications once a day the daily treatments can be doubled if required Identify the area to be treated and position the electrodes as shown in illustration 1 Adjust the intensity until a tingling feeling is produced in the area treated avoid contracting the surrounding muscles Program duration 30 minutes TENS 5 Neck pain Headache Specific program for the treatment of pain in the neck area The intensity should be adjusted to a level betwe
13. pain The average number required to benefit from the treatment is 10 12 per day there are no contraindications for up to double this amount The program has a duration of 40 minutes in a single phase The program can be repeated at the end of the session for particularly persistent pain The nature of the impulse means that the patient may experience an addictive effect due to which the impulse will be felt less and less if necessary the intensity can be increased by one level to counter this effect Position of electrodes form a square above the painful area as shown in illustration 1 TENS 2 Endorphinic TENS This type of stimulation produces two types of effects according to how the electrodes are positioned positioning the electrodes in the dorsal region see photo 08 in the positions manual promotes the endogenous production of morphine like substances capable of raising the pain perception threshold positioning the electrodes to form a square above the painful area as shown in illustration 1 produces a vascularizing effect Vascularization increases arterial flow and consequently aids the removal of algogenic substances and helps to restore normal physiological conditions Treatment duration 30 minutes in a single phase daily frequency Do not position the electrodes close to inflamed areas Intensity adjusted for good solicitation of the part stimulated the sensation must be similar to that of a massage TENS 3 TENS at
14. the leg biceps or the biceps brachii and the triceps The work aims at developing strength With this program muscle relaxation is obtained by simultaneous stimulation from both channels during the last 5 minutes Program duration 24 minutes Stimulation intensity during the contraction enough to produce good muscle contraction voluntary contraction to reduce the sense of discomfort and reach higher intensities Intensity must be increased gradually treatment by treatment without overstraining the muscles Suspend training for a few days in the event of fatigue and proceed with the Fitness 19 program NEMS 15 16 15 16 Sequential tonic contractions upper limbs and trunk 15 lower limbs 16 This program increases microcirculation within and around the muscle fibres treated creating rhythmic contractions fostering better drainage and toning It can also be applied to older people to IACER S r l 25 of 36 MNPG148 Rev 02 02 07 15 TECH improve blood and lymphatic circulation in the lower limbs e g applying 1 to the right calf CH2 to the right thigh Program duration 18 minutes These programs be catried out using self adhesive electrodes Stimulation intensity must be sufficient to produce good muscle contractions during the treatment but not enough to cause any soreness It mainly works on slow twitch fibres NEMS 17 18 Sequential phasic contractions upper limbs and trunk 17 lower limbs 18 Th
15. withstand intense exertion for a longer amount of time in muscle regions subjected to stimulation Indicated for sporting disciplines involving long intense periods of exertion Stimulation intensity during the contraction start with a low level of intensity increasing it gradually For practiced athletes the intensity used should be enough to produce visible muscle contractions Program duration 29 minutes In the event of muscle ache after stimulation use the Fitness 19 program muscle relaxant NEMS 6 7 Basic strength upper limbs and trunk 6 lower limbs 7 The Basic strength program is used in sport to develop basic strength which for definition is the maximum tension that a muscle can exert against constant resistance The contractions alternate with periods of active recovery during the work phase allowing the muscle to be trained without subjecting it to stress and improving oxygenation of the same muscle Program duration 24 minutes The following basic procedure will enable you to obtain the first results two sessions per week for each muscle region for the first three weeks at medium low intensity three sessions per week for the next three weeks at high intensity Intensity must be increased gradually treatment by treatment without overstraining the muscles Suspend training for a few days in the event of fatigue and proceed with the Fitness 19 program IACER S r l 24 of 36 MNPG148 Rev 02 02 07 15 I
16. 00us x 5 sec 100 frequency 10 Hz 15Hz 100ps x 5 sec 95 frequency 12 Hz impulse width 1001s 3Hz 100us x 5 sec 100 impulse width 1001s 95 40 cycles Total time 30 min 1 3Hz 300us 100 B14 1 5Hz 250ps 100 1 8Hz 200us 100 10 cycles Total time 10 min Total time 5 min Total time 10 min frequency 3 Hz frequency 1 Hz 100 3Hz 200ps x 5 B15 sec 100 x 60 cycles impulse width 300us impulse width 300us BEAUTY 1 2 Firming up upper limbs and trunk Firming up lower limbs Indicated for firming up muscles in the arms and bust Beauty 1 or the legs Beauty 2 working mainly on slow twitch fibres Duration 29 minutes Suitable for those who have never done any physical activity or have been inactive for a long period of time Method of use identify the muscle to be treated To obtain good results it is best to treat just a few muscles at a time and complete the process described below position the electrodes as shown in the photo increase the intensity until the impulse can be felt use a low intensity for the first session to help you to understand how the machine works IACER 544 18 of 36 MNPG148 Rev 02 02 07 15 TECH e during the program and over the next few days the intensity should be increased gradually so that muscle contractions are not painful e during contraction generated by the unit contract the muscle voluntarily e a cycle of 15 20 appli
17. 02 02 07 15 I TEGH MEDICAL DIVISION BEAUTY 7 Modelling Due to a combination of capillarizing and toning impulses this program helps mobilise fat in areas where it tends to accumulate The electrodes should be positioned to form a square atound the area to be treated and can be applied daily using a medium intensity Program duration 14 minutes Recommended stimulation intensity medium Position of electrodes see photos 01 to 20 and photo 22 and 23 in the manual of positions BEAUTY 8 Microlifting The following program with a duration of 14 minutes is used to tone facial muscles using a special impulse to improve both the appearance and the dynamism of facial muscles The position of the electrodes is shown in the manual of electrode positions photo 24 N B a minimum distance of 3 cm must be kept between the electrode and the eyeball IMPORTANT take care when adjusting the intensity as facial muscles particularly sensitive intensity should be increased gradually starting with a very low level of stimulation just above perception and increasing with care until you reach a good level of stimulation represented by good muscle activation Z IMPORTANT it is not necessaty to reach levels of intensity capable of causing discomfort The equation more pain more gain is completely misleading and counterproductive Great and significant results are obtained through consistency and patience BEAUTY 9 10 11 1
18. 2 Lipolysis abdomen 9 thighs 10 glutei and hips 11 arms 12 These specific drainage programs increase microcirculation within and around the muscle fibres treated and create rhythmic contractions facilitating the discharge of algogenic substances and promoting lymphatic activity It can also be applied to older people to improve blood and lymphatic circulation The program produces sequential tonic contractions reproducing the typical effect of electronic lymphatic drainage There are no real limits of application for these programs which can be practiced until the desired result has been achieved Stimulation intensity must be sufficient to produce good muscle contractions during the treatment but not enough to cause any soreness Duration 29 minutes The first results can usually be seen after 3 4 weeks practicing 4 5 sessions a week Beauty 9 lipolysis abdomen photo 20 Beauty 10 lipolysis thighs photo 21 Beauty 11 lipolysis glutei photo 19 and hips photo 23 Ch1 on one hip and Ch2 on the other Beauty 12 lipolysis arms photo 15 and 16 Ch1 on one atm and Ch2 on the other BEAUTY 13 Tissue elasticity Program lasting 19 minutes that stimulates surface muscle fibres The frequencies used facilitate the removal of substances accumulated on the surface and improve the dynamic appearance of the skin Intensity should be set to produce surface vibrations Position the electrodes to form
19. Hz Total time 5 min ime 4 min N14 250 8sec CH1 amp CH2 Frequency 10 Hz Frequency 6 Hz 80 50Hz 250 5 x 6 sec 75 CH1 50Hz 2505 6 impulse width 250 Ise width 2505 E p sec 75 CH2 x 45 cycles 80 Total time 3 min Total time 10 min 30Hz Total unie hts N15 sx 5 sec 80 eae Gar Frequency 6 Hz 200ps 5 sec 80 CH1 Frequency 4 Hz 30Hz 200ps x 5 sec 80 impulse width 200ps CH2 x 60 cycles 90 7 A p 0 Total time 3 min Total time 10 min 30Hz Total umae ymin N16 n gt Frequency 6 Hz 300 x 5 sec 80 CH1 Frequency 4 Hz i 30Hz 300us 5 sec 80 impulse width 300us impulse width 300ps CH2 x 60 cycles 90 DE 0 Total time 3 min Total time 10 min 50Hz Total tme 5 min N17 sx se gt Frequency 6 Hz 200us 5 sec 75 CH1 Frequency 4 Hz 50Hz 200ps x 5 sec 75 impulse width 200us impulse width 200ps 2 x 60 cycles 0 0 Total time 3 min Total time 10 min 50Hz Hotel diate amin N18 sx 5 sec 75 Frequency 6 Hz 300 x 5 sec 75 CH1 Frequency 4 Hz 50Hz 300us x 5 sec 75 3001s impulse width 300ps 2 60 cycles m 0 N19 Total time 10 min 3Hz Total time 10 min Total time 10 min 250 7sec 80 1Hz 250 100 20Hz Frequency 6 Hz Frequency 2 Hz IACER S r l 23 of 36 MNPG148 Rev 02 02 07 15 E Ew MEDICAL DIVISION 250ps x x 40 impulse width 250us 90 impulse width 25045 c
20. MEDICAL DIVISION USER MANUAL 148 Rev 2 02 07 15 Electrotherapy model MIO CARE PRO I TECH IACER S r l 2 of 36 MNPG148 Rev 02 02 07 15 MEDICAL DIVISION Summary Technical Specifications Manufacturer Declaration of Conformity Specifications Purpose Technical features Labels detail Symbols description Kit contents How to use Warnings Electromagnetic interference Contraindications How to use TENS Programs Programs Technical Specifications Maintenance Battery charging Battery replacement Cleaning Carriage and storage Disposal Troubleshooting Assistance Spare sparts Warranty EMC Tables IACER S r l 3 of 36 000 00 41 03 03 Da A Q N WWWNNNNNDND WN oso o o oo Oo OO MNPG148 Rev 02 02 07 15 I TECH MEDICAL DIVISION Technical Specifications Manufacturer LA C E R S r l Via S Pertini 24 a 30030 Martellago VE Tel 041 5401356 Fax 041 5402684 S r l is an Italian medical devices manufacturer CE medical certificate n MED24021 issued by Cermet notified body n 0476 Declaration of Conformity S r l headquartered in Italy via S Pertini 24 A 30030 Martellago VE declares on its own responsibility that MIO CARE PRO is manufactured in conformity with Directive 93 42 EEC MDD dated 14 June 1993 D Lgs 46 97 dated 24 February 1997 Attuazione della Diret
21. Photo 25 5 5 Daily even twice a Cervicogenic headache TENS 5 0 12 Photo 25 day Photo 25 but with Back pain TENS 6 0 12 Daily all electrodes placed 10 cm lower Backache TENS 6 2 15 Daily Photo 27 Sciatic pain TENS 6 5 20 Daily tage a Photo 28 Photo 18 with all 6 Daily even twice electrodes placed on Cruralgia 5 20 day the inside of the thigh Daily even twice a Epicondylitis TENS 15 5 20 d duy Photo 29 Hip pain TENS 1 0 20 FA ps Photo 30 Knee pain TENS 1 0 20 pu p Photo 31 Ankle sprain TENS 3 5 7 Daily p to 2 3 Photo 32 times a day Carpal tunnel syndrome TENS 1 10 12 Daily js Photo 33 Trigeminal neuralgia TENS 18 10 12 Daily Photo 24 2 TENS 1 Daily even twice a Wryneck TENS 9 8 10 diy Photo 25 Periarthritis TENS 17 15 20 Daily Photo 26 IACER S r l 16 0f 36 MNPG148 Rev 02 02 07 15 MEDICAL DIVISION Important for all of these programs stimulation intensity must be set between the threshold of impulse perception and the moment in which the impulse starts to cause discomfort With the exception of the periarthritis program the muscles surrounding the area to be treated must not contract they should only produce slight vibrations BEAUTY Programs PHASE 1 PHASE 2 PHASE 3 Total time 4 min Total time 15 min 3Hz 200 7sec 80 1Hz
22. T to confirm Adjust frequency Hz pressing A increase and decrease CH1 or CH2 buttons Press SET to confirm Adjust width impulse us pressing A increase and decrease 1 or CH2 buttons Press OK to confirm 3 INTENSITY ADJUSTEMENT Increase intensity current of two channels using CH1 and CH2 buttons The value can be adjusted with 1mA stepping Decrease the intensity pressing W buttons TENS In TENS programs the intensity should be adjusted to a level between the thresholds of perception and pain the maximum intensity level is the moment in which the muscles surrounding the area treated begin to contract It is suggested to stop before that point The electrodes should be positioned to form a square surrounding the painful area using Channel 1 and Channel 2 as shown in illustration 1 Red T WARNING Painful Shans area Create square area with the electrodes over the painful zone Black Black Keep 4cm minimum distance between electrodes IACER S r l 10 of 36 MNPG148 Rev 02 02 07 15 e MEDICAL DIVISION Programs TENS BEAUTY NEMS MEM Conventional Tens Firming up 1 R 1 upper limbs 1 Warming up 1 Free TENS 1 fast and trunk Endorphinic Tens Firming up 2 2 2 upper limbs and 2 Free TENS 2 delayed lower limbs trunk Tens at maximum Toning up
23. a square around the area to be treated BEAUTY 14 Capillarization The capillarization program significantly increases arterial flow in the area treated The capillarization program is very useful for recovering after intense aerobic work toning up training and improves IACER S r l 20 of 36 MNPG148 Rev 02 02 07 15 I TECH MEDICAL DIVISION local microcirculation Program duration 30 minutes Recommended stimulation intensity medium Position of electrodes see photos 01 to 20 in the manual of positions BEAUTY 15 Heaviness in legs This program is used to improve blood flow and muscle oxygenation speeding up the elimination of lactic acid produced after anaerobic sessions for muscle definition reducing soreness and the risk of contractures Thanks to this program the muscle treated will be ready for a new training session or competition much more quickly Program duration 25 minutes Recommended initial intensity medium low enough to produce good movement of the part treated increase intensity progressively until the muscle treated is subjected to a strong massage Position of electrodes see photos 01 to 20 in the manual of positions Treatment programs for muscle firming and lipolysis Weekly training program No of Muscle Photo Day1 Day 3 Day 5 Day 7 weeks Abdominal muscles No 1 20 Beauty14 Bl B14 BI Bl 6 firming up Ab
24. arge synthetic substances produced during exertion Program duration 25 minutes Stimulation intensity medium low increased during the last 10 minutes Position of electrodes see photos 01 to 20 in the manual of positions NEMS 20 EMS Program that increases the microcirculation within and around the muscle fibres treated creating rhythmic contractions thus promoting a draining and invigorating Short duration The stimulation intensity must be sufficient to assure good muscular contractions during treatment but such as not to produce soreness The work is mainly about the slow fibres IACER S r l 26 of 36 MNPG148 Rev 02 02 07 15 le MEDICAL DIVISION Treatment programs for muscle strength Weekly training program No of Muscle Photo T SEE Day1 Day 3 Day 5 Day 7 weeks Abdominal muscles No 1 20 Fitness6 F19 F6 F6 F12 5 basic strengt Pectoral muscles No 7 17 F6 F19 F6 F6 F12 5 basic strength Quadriceps No 11 18 F7 F19 F7 F7 12 5 basic strength Glutei No 19 F7 F19 F7 F7 F12 5 basic strength Arms biceps basic No 2 15 F6 F19 F6 6 F12 6 strength Arms triceps basic No 3 16 F6 F19 F6 F6 F12 6 strength WARNING MODERATE INTENSITY DURING THE FIRST TWO WEEKS INCREASING IN THE FOLLOWING WEEKS MEM programs Prg PHASE 1 Free memories TENS Total time 1 90 min frequency 1 200 Hz width impulse 20 250 us M1 M5
25. c propagation is affected by absorption and reflection from structures objects and people IACER S r l 32 of 36 MNPG148 Rev 02 02 07 15 1 A C E R S r l Sede operativa 30030 Martellago VE Via S Pertini 24 A Tel 39 041 5401356 Fax 39 041 5402684 Sede legale S Marco 2757 30124 Venezia Cod Fisc P VA IT 00185480274 R EA VEN 120250 VE001767 Cap Soc 110 000 00 i v www iacer it iacer iacer it
26. cations must be completed before the first results can be seen one application for each muscle evety two days with a day of rest in between It is possible to work on pairs of muscles for example thighs and abdominal muscles treating one set one day and the other the next day Working on too many muscles at the same time is not recommended BEAUTY 3 4 Toning up upper limbs and trunk Toning up lower limbs Indicated for toning up muscles in the arms and bust Beauty 3 or the legs Beauty 4 working mainly on fast twitch fibres Duration 29 minutes Suitable for people who already practice moderate physical activity Method of use identify the muscle to be treated To obtain good results it is best to treat just a few muscles at a time and complete the process described below position the electrodes as shown in the photo e increase the intensity until the impulse can be felt use a low intensity for the first session to help you to understand how the machine works e during the program and over the next few days the intensity should be increased gradually so that muscle contractions ate not painful e during contraction generated by the unit contract the muscle voluntarily a cycle of 15 20 applications must be completed before the first results be seen application for each muscle every two days with a day of rest in between It is possible to work on pairs of muscles for example thighs and ab
27. dominal muscles No 20 B14 B1 B14 B1 8 post partum Pectoral muscles No 7 17 B14 B1 B B1 6 firming up Thighs No 11 18 B14 B2 B14 B2 B2 5 firming up 19 B14 B2 B14 B2 B2 5 firming up Arms biceps A No 2 15 B14 B1 14 B1 1 5 firming up DIVAS SS No 3 16 B14 B1 B14 B1 B1 5 firming up lipolysis No 20 B9 B14 B9 B1 6 abdomen Lipolysis 55 No 21 B10 B14 B10 B2 6 thighs Lipolysis m No 19 B11 B14 B11 B2 6 glutei Lipolysis No 23 Chl on right hips hip Ch2 on left hip 28 pini EM He 5 No 15 16 4 Lipolysis electrodes on right arms arm and 4 Ch2 ones Eu By 9 on left arm WARNING MODERATE INTENSITY DURING THE FIRST TWO WEEKS INCREASING IN THE FOLLOWING WEEKS IACER S r l 21 of 36 MNPG148 Rev 02 02 07 15 I 0 MEDICAL DIVISION NEMS programs Total time 10 min 5Hz Total time 3 min Total time 3 min 250us x 7sec 80 1Hz Frequency 6 Hz Frequency 8 Hz 250us 3 sec 100 NI 25005 x 5 se impulse width 250ps impulse width 250ps 40 cycles Total time 4 mi Total time 15 min 3Hz Total time 15 min 3Hz im min 2005 9sec 80 1Hz 2005 9sec 80 1Hz W Frequency 6 Hz 200us x 3 sec 100 20Hz 200us x 3 sec 100 cu gt 0 PA d 3 0 impulse width 200us 200 x 8 sec 80 x 45 30Hz 200ys x 8 sec 80 cycles x 45 cycles Total time 4 mi Total time 15 min 3Hz Tota
28. dominal muscles treating one set one day and the other the next day Working on too many muscles at the same time is not recommended BEAUTY 5 6 Definition upper limbs and trunk Definition lower limbs Indicated for defining muscles in the arms and bust Beauty 5 or the legs Beauty 6 working mainly on explosive fibres Duration 19 minutes Suitable for people who already practice good physical activity and wish to define their muscles in greater detail Method of use identify the muscle to be treated To obtain good results it is best to treat just a few muscles at a time and complete the process described below position the electrodes as shown in the photo e increase the intensity until the impulse can be felt use a low intensity for the first session to help you to understand how the machine works e during the program and over the next few days the intensity should be increased gradually so that muscle contractions ate not painful e during contraction generated by the unit contract the muscle voluntarily 0 a cycle of 15 20 applications must be completed before the first results can be seen one application for each muscle every two days with a day of rest in between It is possible to work pairs of muscles for example thighs and abdominal muscles treating one set one day and the other the next day Working on too many muscles at the same time is not recommended IACER S r l 19 of 36 MNPG148 Rev
29. e capacity of fast twitch fibres to withstand strain over extended periods of time For an athlete with good resistance the capillarization program is very useful for recovery after intense aerobic work before anaerobic work and when training is not possible due to bad weather or an injury Program duration 30 minutes Recommended stimulation intensity medium Position of electrodes see photos 01 to 20 in the manual of positions in relation to the area that you wish to stimulate NEMS 13 Muscle recovery Can be used for all sports after competitions or the most demanding training sessions in particular after long and intense exertion To be used immediately after exertion Helps drainage and winding down improving muscle oxygenation and helping to discharge synthetic substances produced during exertion Program duration 25 minutes Stimulation intensity medium low increased during the last 5 minutes Position of electrodes see photos 01 to 20 in the manual of positions in relation to the area that you wish to stimulate NEMS 14 Agonist Antagonist The electronic stimulator produces contractions alternated between 2 channels during the first 4 minutes of watm up the 2 channels work simultaneously during the central work phase 15 minutes muscle contractions are alternated between Channel 1 agonist muscles and Channel 2 antagonist muscles The program is designed to restore muscle tone to the quadriceps and its antagonist
30. e level in each frequency rage Interference may occur in the vicinity of equipment marked with the following symbol Recommended separation distances equipment and the device between portable and mobile communications The device is intended for the use in an electromagnetic environment in which radiated RF disturbances are controlled The customer or the user of the device can help prevent electromagnetic interferences by maintaining a minimum distance between portable and mobile RF communications equipment transmitters and the device as recommended below according to the maximum output power of the communication equipment Rated maximum Separation distance according to the frequency of the transmitter m power of the transmitter W 150kHz to 80MHz 80MHz to 800MHz 800MHz to 2GHz 4 1 2 1 d 1 2 VP 2 3 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10 3 8 3 8 100 12 12 23 For transmitters rated at maximum output power not listed above the recommended separation distance d in mettes m can be estimated using the equation applicable to the frequency of the transmitter where P is the maximum output power trating of the transmitter in Watts W according to the transmitter manufacturer Note 1 At 80 MHz and 800 MHz the separation distance for the higher frequency range applies 2 These guidelines may not apply in all situations Electromagneti
31. e program using PRG and PRG buttons please make reference to Programs list to get all technical specifications 2 INTENSITY SELECTION You can increase current intensity using CH1 and CH2 buttons up arrow The value can be adjusted with stepping of 1 mA Press CH1 and CH2 buttons down arrow to decrease the intensity IACER S r l 9 of 36 MNPG148 Rev 02 02 07 15 I TECH MEDICAL DIVISION MIO CARE PRO tecognize the electrodes connection in case of faulty connection when the intensity reaches 10 mA the value is resetted to zero The remaining time is showed on the display of MIO CARE PRO An acoustic signal advises the user when the treatment is completed 5 Press the button to pause the treatment To restart the program press O OK button Turn off the device keeping pressed the O OK button for at least two seconds The device automatically switches off when no button is pressed for 2 minutes FREE MEMORIES ADJUSTABLE PROGRAMS With MIO CARE PRO you can set the parameters according to your needs using the MEM programs Read the following instructions to adjust the parameters 1 PROGRAM SELECTION Select MEM by pressing MODE ESC button Scroll the programs using PRG and PRG buttons Read the following instructions to adjust the program parameters time frequency and width impulse 2 PARAMETERS ADJUSTEMENT e Adjust therapy time TIME min pressing increase and decrease CH1 or CH2 buttons Press SE
32. e sections can cause skin reactions or burns Do not use electrodes when damaged even if they stick to the skin well e Useonly cables and electrodes supplied by device manufacturer IACER S r l 8 of 36 MNPG148 Rev 02 02 07 15 Electrodes must not be used when they no longer stick to the skin Repeated use of the same electrodes can compromise the safety of the stimulation in fact it can cause skin redness that can last for many hours after stimulation The manufacturer is responsible of the performances safety and integrity of the device only if 0 Eventual additions modifications and or reparations are performed authorized personnel 0 The electrical system is in compliance with the national laws The device is used in compliance with the instructions of the user manual Electromagnetic interference The device does not produce and receive any interferences from others equipment However it is recommended the use of the device at least 3 metres away from televisions monitors mobile phones or any other electronic equipment Contraindications Patient in pregnancy tuberculosis juvenile diabetes viral in acute phase illnesses mycosis dermatitis cardiopathic subjects tumours serious arrhythmias or pacemaker carriers children metallic prosthesis carriers acute infections open wounds epileptics different medical prescriptions excepted No significant side effects are known of Some partic
33. elops its effectiveness after this type of injury by inhibiting pain locally producing three selectively acting differentiated impulses The intensity should be adjusted to a level between the thresholds of perception and pain Number of treatments until pain is lessened on a daily basis even 2 3 times a day TENS 8 Vascularization Has a vascularizing effect on the area treated Vascularization increases arterial flow and consequently aids the removal of algogenic substances and helps to restore normal physiological conditions Do not position the electrodes close to inflamed areas Daily application is recommended the number of applications is not defined the program can be used to reduce pain Stimulation intensity should be between the thresholds of perception and slight discomfort Program duration 20 minutes Position of electrodes see photo 25 and 33 in the manual of positions IACER S r l 14 0f 36 MNPG148 Rev 02 02 07 15 I TECH MEDICAL DIVISION TENS 9 Muscle relaxant Program used to speed up the recovery of muscle function after intense training or strain from work the effect is immediate Adjust the intensity for moderate muscle solicitation Two treatments per day for three or four days Program duration 30 minutes Position of electrodes from photo 1 to 28 TENS 10 Hand and wrist pain This program is suitable for all types of hand and wrist pain aching caused by strains arthritis in the hand carpa
34. en the thresholds of perception and pain the maximum intensity level is the moment in which the muscles surrounding the area treated begin to contract over this limit stimulation does not become mote effective just mote irritating so it is best to stop before that point The first benefits can be seen after 10 to 12 treatments carried out on a daily basis proceed with the treatment until the symptoms pass Position of electrodes photo 25 Warning the device varies stimulation parameters during the program The current may feel different this is perfectly normal and is envisaged by the software raise or lower the intensity according to your own sensitivity to reach a level of stimulation that is comfortable for you TENS 6 Backache Sciatic pain Specific program for the treatment of pain in the lumbar area or along the sciatic nerve or both The intensity should be adjusted to a level between the thresholds of perception and pain the maximum intensity level is the moment in which the muscles surrounding the area treated begin to contract over this limit stimulation does not become mote effective just more irritating so it is best to stop before that point The first benefits can be seen after 15 to 20 treatments carried out on a daily basis proceed with the treatment until the symptoms pass Program duration 40 minutes Position of electrodes see photo 27 and 28 in the manual of positions TENS 7 Sprains Bruises The program dev
35. f the problem persists contact the manufacturer MIO CARE PRO transmits low intensity or intermittent impulses Check the cables and the electrodes are in good condition and replace them if it is necessary If the problem persists contact the manufacturer MIO CARE PRO switches off during the operation It is suggested to replace the battery and start a new treatment If the problem persists contact the manufacturer MIO CARE PRO does not allow the intensity adjustment or not keep the adjusted value and reset It is suggested to replace the battery and start a new treatment If the problem persists contact the manufacturer IACER S r l 29 of 36 MNPG148 Rev 02 02 07 15 Assistance Every intervention on device must be performed by manufacturer For any assistance intervention contact the National Distributor or the manufacturer at the following address LA C E R S r l Via S Pertini 24 a 30030 Martellago VE Tel 041 5401356 Fax 041 5402684 Technical documentation concerning the spare parts can be supplied by the manufacturer but only prior business authorization and specific training Spare sparts For original spare parts contact the National Distributor or the manufacturer at following address LA C E R S r l Via S Pertini 24 a 30030 Martellago VE Tel 041 5401356 Fax 041 5402684 To preserve product warranty functionality and product safety we recommend to use only original s
36. is program produces rhythmic contractions with a stimulation frequency typical of fast twitch fibres It is suitable for increasing muscle strength sequentially The programs produce sequential phasic contractions on both channels Stimulation intensity must be sufficient to produce good muscle contractions during the treatment but not enough to cause any soreness Program duration 18 minutes Unlike the previous program this one uses a higher stimulation frequency during the contraction hase and therefore works mainly on fast twitch fibres y NEMS 19 Muscle relaxant Can be used for all sports after competitions or the most demanding training sessions in particular after long and intense exertion To be used immediately after exertion Helps drainage and capillarization improving muscle oxygenation and helping to discharge synthetic substances produced during exertion Program duration 30 minutes Stimulation intensity medium low increased during the last 10 minutes Position of electrodes see photos 01 to 20 in the manual of positions NEMS 20 Deep massage Can be used for all sports after competitions or the most demanding training sessions in particular after long and intense exertion Program similar to the previous one however it uses lower frequencies with a greater capacity for vascularization To be used immediately after exertion Helps drainage and capillarization improving muscle oxygenation and helping to disch
37. l time 15 min 3Hz ime 4 min e 300ps x 9sec 80 1Hz 300ps x 9sec 80 1Hz T Frequency 6 Hz 300us x 3 sec 100 20Hz 300ps x 3 sec 100 di pale width dns 300ps x 8 sec 80 x 45 20Hz 300ps x 8 sec 80 cycles x 45 cycles Total time 4 mi Total time 15 min 3Hz Total time 10 min 3Hz ae 200ps x 9 80 1Hz 200ps 7sec 80 1Hz Frequency 6 Hz 200 x 3 sec 100 40Hz 200s x 3 sec 100 impulse width 2001s 200 x 8 sec 80 x 45 50Hz 200ys x 5 sec 75 cycles x 40 cycles Total time 4 mi Total time 15 min 3Hz Total time 10 min 3Hz im min 300 x 9sec 80 1Hz 300us 7sec 80 1Hz N Frequency 6 Hz 300us x 3 sec 100 20Hz 300us x 3 sec 100 impulse width 300us 300ps x 8 sec 80 x 45 50Hz 300ys 5 sec 75 cycles x 40 cycles Total ipio Total time 10 min 3Hz Total time 10 min 3Hz 200s x 7sec 80 1Hz 200ps x 7sec 80 1Hz T Frequency 6 Hz 200us x 3 sec 100 50Hz 200ps x 3 sec 100 gt 20014 200ps 5 sec 75 x 40 60Hz 200ps x 5 sec 75 cycles x 40 cycles Total time 4 mi Total time 10 min 3Hz Total time 10 min 3Hz al tim min 5 300ps x 7sec 80 1Hz 300ps x 7sec 80 1Hz 10 Frequency 6 Hz 300 x 3 sec 100 50Hz 300ps 3 sec 100 impulse width 300us 300 x 5 sec 75 x 40 60Hz 300ps x 5 sec 75 cycles x 40 cycles Total time 4 mi Total time 10 min 3Hz Total time 10 min 3Hz im min ee 200ps x 7sec 80 1Hz 200ps x 7sec 80 1Hz F
38. l tunnel syndrome etc Total program duration 40 minutes A combination of various types of squate wave impulses has a general analgesic effect on the area to be treated impulses at different frequencies stimulate different sized nerve fibres promoting an inhibitory action at spinal level The intensity should be adjusted to a level between the thresholds of perception and pain without causing muscle contraction Position of electrodes form a square above the area to be treated as shown in illustration 1 TENS 11 Plantar stimulation This program has a relaxing and draining effect on the limb stimulated It is ideal for people suffering from a sense of heaviness in the legs Duration 40 minutes Intensity just above the threshold of perception Position of electrodes 2 electrodes one positive the other negative on the sole of the foot one close to the toes the other under the heel TENS 12 Epicondylitis Also known as tennis elbow it is an insertional tendinopathy concerning insertion of the elbow bone into the epicondylar muscles those enabling finger and wrist extension bending backwards 15 applications once a day even twice until the symptoms pass We recommend that you consult your doctor to identify the precise cause of the pain in order to prevent the condition from reoccurring Program duration 40 minutes intensity adjusted above the threshold of perception Position of electrodes photo 29 TENS 13
39. ommend to put away MIO CARE PRO and its accessories in their own bag after every treatment Storage precautions MIO CARE PRO is protected till following environmental conditions In operation Temperature from 5 to 40 C Rel humidity from 30 to 75 Pressure from 700 to 1060 hPa Inside of the packaging Temperature from 5 to 55 C Rel humidity from 10 to 90 Pressure from 700 to 1060 hPa Disposal The equipment is subjected to WEEE regulations see the symbol the label concerning separate waste collection when disposing this product please use the designed areas for disposing electronic waste or contact the manufacturer Troubleshooting If it is used in accordance with the instructions of the user manual MIO CARE PRO does not need a particular regular maintenance If you find any malfunctioning using MIO CARE PRO please follow these instructions e MIO CARE PRO does not turn on and or the display does not light up Check the battery status and replace it if it is necessary make reference to chapter Battery replacement If the problem persists contact the manufacturer MIO CARE PRO does not transmit electric impulses Check that the cable jacks have been inserted in the electrodes and that the plastic protection has been removed from the electrode Check that the cables have been connected correctly connector well inserted in the device Check that the cables and the electrodes are not damaged I
40. pare parts Warranty Make reference to the national laws for any warranty conditions by contacting the national distributor or directly the manufacturer IACER MIO CARE PRO All tights reserved MIO CARE PRO nivision logos owned by LA C E R Srl and are registered IACER S r l 30 of 36 MNPG148 Rev 02 02 07 15 O MEDICAL DIVISION EMC Tables Electromagnetic emission Emission test Compliance Electromagnetic environment guidance RF emissions Group 1 The device uses RF energy only for its Cispr 11 internal function Therefore its RF emissions very low and are not likely to cause any interference in nearby electronic equipment RF emissions Class B The device is suitable for use in all Cispr 11 establishments including domestic establishments and those directly connected to the public low voltage power supply network that supplies buildings used for domestic purposes Electromagnetic immunity The device is inteded for use in the electromagnetic environment specified below The customer or the uset of the device should assure that is used in suche environment Immunity test Test level EN Compliancelevel Electromagnetic environment 60601 1 2 guidance Electrostatic discharge 6kV contact 6kV contact Floors sholud be wood concrete ESD 8KV air or ceramic tile If floor are EN 61000 4 2 covered with syntethic material the
41. r l 15 of 36 MNPG148 Rev 02 02 07 15 Q MEDICAL DIVISION Program duration 41 minutes intensity set above the threshold of perception with small muscle contractions at the end of the program 10 minutes before the end ARTHROSIS Arthrosis is a chronic degenerative medical condition appearing insidiously developing over time and causing progressive degeneration of the joints a joint is formed of two or more joint heads cartilage ligaments a synovial membrane a joint capsule tendons and muscles limiting joint motility increasingly over time Arthrosis mainly causes progressive deterioration of cartilage which is not capable of re forming and bone with secondary deformation of the same and production of excrescences called osteophytes which mechanically obstruct joint movement it also causes the joint capsule to thicken and stiffen which together with contraction of the muscles surrounding the joint limits the joint excursion even further Tens therapy can lessen the pain caused by this condition but cannot cure it Tens Tens 1 can be combined with stimulation of the area to be treated using a low frequency current Tens 2 to relax the surrounding muscles Pathology Program No of treatments Treatment Position of frequency electrodes TENS i Untilpainis PAD TENSI up to Arthrosis ML 2 3 times a day On the painful area TENS 2 lessened TENS 2 once a day Neck pain TENS 5 0 12 Daily ASCA
42. relative humidity should be at least 30 Mains power 3 A m Mains power quality should be electromagnetic field at that of a typical commercial or EN 61000 4 8 hospital environment IACER S r l 31 of 36 MNPG148 Rev 02 02 07 15 MEDICAL DIVISION Guidance and manufacturer s declaration electromagnetic immunity The device is inteded for use in the electromagnetic environment specified below The customer or the user of the device should assure that is used in suche environment Immunity test Test level EN Compliance level Electromagnetic environment 60601 1 2 guidance Conducted RF 3 Vrms 150kHz 3 Vrms 150kHz to Portable and mobile RF EN 61000 4 6 to 80MHz 80MHz communications equipment should be RF Radiata 3 Vrms 80MHz 3 Vrms 80MHz to used no closer to any part of the device EN 61000 4 3 to 2 5GHz 2 5GHz including cables than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter Recommended separation distance d 1 2 NP 150kHz to 80MHz d 1 2 80 MHz to 800 MHz d 2 3 800 MHz to 2 5 GHz where P is the maximum output power rating of the transmitter in Watts W according to the transmitter manufacturer and d is the recommended separation distance in metres m Field strangths from fixed RF transmitters are determined by an electromagnetic site survey should be less than the complicanc
43. requency 6 Hz 200 x 3 sec 100 70Hz 200s x 3 sec 100 impulse width 200 ua 200ps x 5 sec 80 x 40 80Hz 200ys x 5 sec 80 cycles x 40 cycles tempo tot 4 min Tempo totale 10 min 3Hz tempo tot 10 min 3Hz 300ps 7sec 80 1Hz 300ps x 7 80 1Hz Frequency 6 Hz 300ps x 3 sec 100 70Hz 300ps 3 sec 100 N9 impulse width 300us 200 5 5 sec 80 x 40 80Hz 300us x 5 sec 80 S r l 22 of 36 MNPG148 Rev 02 02 07 15 MEDICAL DIVISION Total time 4 min cycles Total time 10 min 3Hz x 40 cycles Total time 10 min 3Hz N10 200ps x 12sec 90 1Hz 200ps x 12sec 90 1Hz Frequency 6 Hz 200ps x 3 sec 100 200 x 3 sec 100 P sa 0 5 Be 0 impulse width 20006 100Hz 200ps x 5 sec 80 x 120Hz 200ps x 5 sec 80 30 cycles x 30 cycles Total time 10 min 3Hz Total time 10 min 3Hz Total time 4 min NH 300ps x 12sec 90 1Hz 300ps x 12sec 90 1Hz Frequency 6 Hz 300 x 3 sec 100 300 x 3 sec 100 impulse ls 3004s 100Hz 300ps x 5 sec 80 x 120Hz 300ps x 5 sec 80 30 cycles x 30 cycles Total time 30 min 20 sec N12 5Hz 200ps 100 20 sec 8Hz 1501s 100 20 sec 12Hz 100 100 x 30 cycles Total time 10 min Total time 5 min 5Hz 250ps Total time 10 min N13 Frequency 6 Hz a Tee 80 0 Aa 003 Frequency 2 Hz sec 100 20Hz 250ps x 5 impulse width 250 sec 80 x 20 cycles impulse width 250 Total time 4 mi Total time 15 min 5
44. s Total time 4 min Total time 5 min me Total time 5 min 5Hz 250ps B7 frequency 6 Hz frequency 12 Hz x 5sec 90 30Hz 250us x 5 O 0 7 impulse width 25048 impulse width 250ps 90 90 x 30 cycles Total time 4 min Total time 10 min 5Hz ad Bagni 1o Ho 100ps x 10sec 90 20Hz 100ps x 5 sec 90 x 40 impulse width 100 cycles IACER S r l 17 of 36 MNPG148 Rev 02 02 07 15 I TECH Total time 4 min Total time 20 min 5Hz 250ps x 8 sec ch1 ch2 Total time 5 min 9 frequenza 6 Hz 80 40Hz 250ps x 6 sec frequenza 3 Hz impulse width 250ps chi 80 40Hz 250us impulse width 250ps 80 sec ch2 80 x 60 cycles Total time 20 min Total time 4 min Total time 5 min 5Hz 300ps x 8 sec ch1 ch2 Bio frequency 6 Hz 80 40Hz 300ps x 6 sec frequency 3 Hz impulse width 300 chi 80 40Hz 300us impulse width 300us 80 sec ch2 80 x 60 cycles Total time 20 min Total time 4 min Total time 5 min 5Hz 250ys x 8 sec ch1 ch2 frequency 6 Hz 80 40Hz 250ps x 6 sec frequency 3 Hz impulse width 250ps chi 80 40Hz 250us x impulse width 250ps 80 sec ch2 809 x 60 cycles Total time 20 min Total time 4 min Total time 5 min 5Hz 200ps x 8 sec ch1 ch2 i frequency 6 Hz 80 40Hz 200ps x 6 sec frequency 3 Hz impulse width 200 chi 80 40Hz 200us 6 impulse width 200ps 80 sec ch2 80 x 60 cycles Total time 10 min Total time 4 min Total time 5 min 5Hz 1
45. tiva 93 42 CEE concernente i dispositivi medici Annex II as modified by Directive 2007 47 CE dated 5 September 2007 D Lgs 37 2010 dated 25 January 2010 Notified body Cermet Via di Cadriano 23 40057 Cadriano di Granarolo BO Italy MIO CARE PRO is a Class Ila equipment with reference to Directive 93 42 EEC MDD annex IX tule 9 and following modifications Certification Path Annex II Martellago 01 07 2014 Legal Rappresentative Mario Caprara Specifications MIO CARE PRO has the following specifications e Class equipment Directive 93 42 CEE Annexed IX rule 9 and following modifications Class II applied part type BF Classif CEI EN 60601 1 Equipment not protected against liquid penetration Equipment and accessories not subjected to sterilization Use of the equipment is prohibited close to flammable substances when mixed with air or with oxygen or with nitrous oxide Continuous operating mode equipment Equipment not suited to be used external IACER S r l 4 of 36 MNPG148 Rev 02 02 07 15 I TECH Purpose Clinical purpose Therapeutic Use Clinic Hospital and domestic use MIO CARE PRO is indicated for the treatment and the functional rehabilitation of the following pathologies and anatomical zones wrist articulation hand articulation shoulder articulation foot articulation ankle articulation knee articulation skeletal motor apparatus arthrosis atrophies
46. ularly sensitive people could report skin redness in the area where the electrodes were positioned the redness usually disappears a few minutes after the end of the treatment Should the redness persist please consult a doctor In rare cases evening stimulation carried out in the evening can cause some people to experience difficulty in falling asleep If this occurs suspend the evening treatment How to use MIO CARE PRO is a portable and battery powered device that generates TENS and NEMS currents It is particularly indicated for daily treatments of the most commons muscle diseases MIO CARE PRO is provided with two independent and adjustable intensity channels MIO CARE PRO has 14 preadjusted TENS programs 21 preadjusted NEMS programs 15 preadjusted BEAUTY programs and 12 free memories adjustable by the user to create programs according to his needs The program MEM 13 is a battery test PRELIMINARY INSTRUCTIONS 1 CABLES AND ELECTRODES CONNECTION Position the electrodes on the skin see the following paragraph connect the electrostimulation cable jacks to the self adhesive electrodes and then connects the cables to the outputs on the upper side of MIO CARE PRO 2 SWITCHING ON OF THE DEVICE Turn MIO CARE on using the O OK button PREADJUSTED PROGRAMS Read the follow instructions to use the preadjusted programs of MIO CARE PRO 1 MENU AND PROGRAM SELECTION Select the menu by pressing MODE button TENS REHA MEM Select th
47. ycles Total time 5 min Total time 10 min 3Hz Total time 10 min 2Hz N20 F 250us x 2 sec ch1 100 2503 x 2 sec ch1 100 requency 3 Hz 3Hz 250ps 2 sec ch2 2Hz 250ps 2 sec ch2 impulse width 250us 100 x 150 cycles 100 x 150 cycles Total time 5 min N21 Frequency 6 Hz impulse width 250us NEMS 1 Warming up all muscle groups Program suitable for use before training sessions or competitions very useful for sports involving g 8 comp ns very uset p 5 maximum effort right from the start Program duration 16 minutes Position of electrodes from photo 1 to photo 20 Recommended stimulation intensity medium the muscle must work without strain NEMS 2 3 Resistance upper limbs and trunk 2 lower limbs 3 The Resistance progtam is used in sports to increase muscle resistance acting mainly on slow twitch fibres Program indicated for endurance sports marathon runners cross country skiers ironman etc Program duration 34 minutes Stimulation intensity during the contraction if not particularly fit start with a low intensity then increase gradually For practiced athletes the intensity used should be enough to produce visible muscle contractions In the event of muscle ache after stimulation use the Fitness 19 program muscle relaxant NEMS 4 5 Resistant strength upper limbs and trunk 4 lower limbs 5 This program is designed to help increase resistance to physical stress or rather
Download Pdf Manuals
Related Search
Related Contents
Logiciel KONZELMANN Michel - Groupe d`étude de la main en orthèse et MK Grader Blade Ashfield/Catalina/Bedford/Contempra 806 Series Hama Luggage Strap with Combination Lock, 5x200 cm, black Quick Draw Electronics Shooting Sports Timer User Manual Model OfficeServ Call User Manual Thermotec Vertical User Manual manuel new VS302.pmd Refractómetro Portátil tipo pluma 45 Copyright © All rights reserved.
Failed to retrieve file