1. system Information Auto Execution EE Operatio ulti serial Port Module O Automatically run EWF Status when log on Windows EWF Control Write Protect enable Success ou must restart this computer for the changes to take effect O Disable Warning 6 Restart XP 8000 Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 82 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com 2 3 1 4 Other Windows XP Embedded Devices The driver can be obtained from name Driver path TP 2070 TP 3080 TPM 4100 TP 4100 CD name Driver Win_XP_Embedded Other XP Embedded devicel TP 5120 TP 6150 TP 7170 For example CD TP 2070 Driver Win_XP_Embedded Other XP Embedded device or go to the PenMount website to download the latest driver http www penmount com down_2_1 php Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 83 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com 2 4 Windows XP 7 The touch driver for 2k XP 2003 2008 Vista 7 is a universal driver USB and Serial both use the same driver 2 4 1 Universal Driver This section describes how to install calibrate and uninstall the universal driver for 2k XP 2003 2008 Vista 7 Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 84 Copyright 2012 ICP DAS Co Ltd All Rig
2. 6 Click Install button to install driver to destination folder PenMount Universal Driver 2 1 0 234 Setup Choose Install Location Choose the folder in which to install PenMount Universal Driver 2 1 0 234 Setup will install PenMount Universal Driver 2 1 0 234 in the Following folder To install in a different Folder click Browse and select another folder Click Install to start the installation Destination Folder Program FilesiPenMount Universal Driver Browse Space required 0 0KB Space available 827 6MB Cancel Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com Page 73 a Tips amp Warnings lf a screen appears that shows Found New Hardware Wizard Do not use this hardware wizard Press Cancel Found New Hardware Wizard Welcome to the Found New Hardware Wizard Windows will search for current and updated software by looking on your computer on the hardware installation CO or on the Windows Update Web site with pour permission Can Windows connect to Windows Update to search for software Yes this time only O Yes now and every time connect a device O No not this time Click Next to continue cance lf a screen appears that shows Hardware Installation Please press Continue Anyway Hardware Installation 4 The software vou
3. button to reboot immediately or click the No button if you intend to reboot at a later Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 68 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com 2 2 2 4 Other Windows CE 6 0 Device The driver can be obtained from Driver path TP 2070 T P 3080 CD name Driver WinCE V6 0 Other CE6 0 device TPM 4100_TP 4100 TP 5120 TP 6150 TP 7170 For example CD TP 2070 Driver WinCE V6 0 Other CE6 0 device or go to the PenMount website to download the latest driver http www penmount com down_2 1 php Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 69 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com 2 3 Windows XP Embedded The touch driver for XP embedded is a universal driver USB and Serial both use the same driver 2 3 1 Universal Driver Two universal touch drivers are available The first is for XP 8000 series modules of ICP DAS PAC controller and the second is for other Windows XP embedded system XP 8000 series 1 Using ATOM CPU XP 8141 Atom XP 8341 Atom XP 8741 Atom 2 Using LX800 CPU XP 8041 XP 8341 XP 8741 Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 70 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com 2 3 1 1 Installation fo
4. file Tips amp Warnings The driver cab file can only be used once If you attempt to use it to AN install driver a second time a warning dialog with a message similar to lt FileName gt is not a valid Windows CE Setup file will be displayed advising that the setup has failed Please re download a new cab file to use Setup Failed The file System _Disk External device _driverPenMount USE is not a valid Windows CE Setup file 3 Depending on the type of CPU one of two dialog windows will be displayed Click the OK button to continue with the installation Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 55 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com Using the ATOM CPU Install ICPDAS Using the LX800 CPU GJ My Device z P gt Application Data mm e System Disk Ci My Documents Install ICPDAS USB PenMount t My Device Se System _Disk AJ My ar Temp Windows gt Application Data C2 Temp OD My Documents O Windows ag Network EF Control Panel 2 Program Files se System_Disk Name MEE Once the installation has been completed a dialog will be displayed advising that the system needs to be rebooted Click the OK button to reboot the XP 8000 CE6 install OK 2 Install complete Press OK button to reboot the system and the settings will take effect Touch Pane
5. All Rights Reserved gt lt E mail service icpdas com TP 3080 Unit mm Top View Left Side View Right Side View Unit mm Bottom View Rear View Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 16 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 17 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com TP 5120 Unit mm Top View 329 Left Side View Front View Right Side View Unit mm Bottom View O La O O O O Rear View Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 18 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com D o Recommended Panel Cut Out Mo qa O O E Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 19 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com TPM 4100 Unit mm de de de de 38 de 38 de 38 e de ee de ee oe ee de Ei 8 de 5 gE 3 ps de E E e Hs oe de oe de o oe 6 oe oe de oe de oe 3 Left Side View Front View CC T 10 0 350 l 10 0 Bottom View Unit mm SRE Top View Touch Panel Monitor User Manual version 1 0 7 Last Revised June 20
6. Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com TP 7170 Unit mm Top View 413 359 Left Side View Front View Rear View Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com Page 26 Unit mm Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 27 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com 1 4 I O interfaces TP 2070 VESA 75 x 75 Mounting 12 48 DC IN Power Switch USB VGA RS 232 TP 3080 TP 5120 TP 6150 TP 7170 VESA Mounting D D Cam Ms s saa 12 48 DCIN VGA RS 232 USB Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 28 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com 7 TPM 4100 OSD USB RS 232 VGA Power Switch 12 48 DC IN TP 4100 VESA 75 x 75 Mounting da casier n e 12 48 DC IN Power Switch VGA RS 232 USB Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 29 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com 1 5 Companion CD This package includes a companion CD that contains a collection of documentation and devic
7. June 2014 Page 53 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com 2 2 1 USB Touch Driver Two USB touch drivers are available The first is for XP 8000 CE6 series modules of ICP DAS PAC controllers and and the second is for other Windows CE6 0 systems XP 8000 CE6 series 1 Using the ATOM CPU XP 8141 Atom CE6 XP 8341 Atom CE6 XP 8741 Atom CE6 XP 8147 Atom CE6 XP 8347 Atom CE6 XP 8747 Atom CE6 XP 8149 Atom CE6 XP 8349 Atom CE6 XP 8749 Atom CE6 2 Using the LX800 CPU XP 8041 CE6 XP 8341 CE6 XP 8741 CE6 XP 8047 CE6 XP 8347 CE6 XP 8747 CE6 XP 8049 CE6 XP 8349 CE6 XP 8749 CE6 XP 8046 CE6 XP 8346 CE6 XP 8746 CE6 Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 54 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com 2 2 1 1 Installation for XP 8000 CE6 The following procedure describes how to install the PenMount USB touch driver 1 Copy the driver from the CD ROM to the XP 8000 CE6 The PenMount_USB_TOUCH_Vxx yyyymmdd_XPAC_CE6 CAP driver file can be obtained from Driver path TP 2070 TP 3080 CD name Driver WinCE V6 0 XP 8000 CE6 device For example CD TP 2070 Driver WinCE V6 0 XP 8000 CE6 device TP 5120 TP 6150 TP 7170 TPM 4100_TP 4100 Or go to the System_DisklExternal_device driver folder on the XP 8000 CE6 2 Double click the PenMount_USB_TOUCH_Vxx_yyyymmdd_XPAC_CE6 CAB
8. Automatically run EWF Status when log on Windows EWF Control Write Protect has been disabled You must restart this computer for the changes to take effect Enable Disable Warning You must restart this computer for the changes to take effect 5 Restart XP 8000 6 Executing XPAC Utility to enable EWF on desktop Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 78 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com XPAC Utility 1 0 5 0 2012 03 27 File Help System Information Auto Execution EWF Operatio ulti serial Port Module O Automatically run EWF Status when log on Windows EWF Control Write Protect enable Success ou must restart this computer for the changes to take effect Disable Warning 7 Restart to XP 8000 for the changes to take effect Change the COM Port For serial touch driver Methodl The touch driver will detect all com port to find what com port connects to serial touch screen monitor automatically when XP 8000 reboots every time Method2 Please refer to the Step 9 of Sec 2 3 1 1 to detect again Simulating Right Mouse Button 1 From the Start menu click Programs gt PenMount Universal Driver gt PenMount Control Panel shee Site FA Accessories Microsoft SQL Server 2005 Documents F FenMount Control Panel Settings j 4 Uninstall Searc
9. Co Ltd All Rights Reserved gt lt E mail service icpdas com 2 2 2 3 Uninstalling the XP 8000 CE6 The following procedure describes how to uninstall the PenMount serial touch driver 1 From the Start menu click Settings gt Control Panel Programs TE Favorites E Documents Ee Settings E Control Panel a Network and Dial up Connections m3 Taskbar and Start Menu 2 Double click the Remove Programs icon and select ICPDAS Serial PenMount from the Programs panel in the Remove Programs dialog box and then click the Remove button When the warning pop up click Yes button to permanently uninstall the driver gt 0 es ass Device Dialing Display Input Panel Keyboard Mouse Network and Owner Password PC Power Management Dial up Co Connection 7 Regional Remove Storage System Settings Program Manager Remove Programs 7 The listed software can be g automatically removed A ICPDAS Serial PenMount remove a program selec from the list and then select Remove Remove Programs Y Virtual CE E Control Panel IR Remove Programs LL y 11 47 PM Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 67 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com 3 Once the uninstallation process is complete a dialog will be displayed requesting that you reboot the system Click the Yes
10. Last Revised June 2014 Page 41 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com 2 1 1 2 Configuration for WinPAC 8000 and WinPAC 5000 Calibration 1 From the Start menu click Programs gt USB_TOUCH gt PenMount gt Calibration ns A TAO Calibration s g BE Command Prompt DrawLiemo fa Programs Internet Explorer 5 RightButton i Favorites E isqhw35 E Uninstall E Documents BF Microsoft WordPad Settings EA Regview Help Fa TaskMgr Run 2 Windows Explorer virtual Al WINPAC Utility 2 Follow the instructions on the screen to begin calibration ie Petiri Calibrate Program Cire 2 7 Prime 6000 6 0 0 Pea Dore Ef nied Gee 3 Once calibration has been completed from the Start menu click Programs gt Open the WinPAC Utility and then click the Save and Reboot option from the File menu WinPAG Utility 2 0 2 7 aCA Help Configuration Save and Reboot REDO Restore Default Settings Exit Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 42 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com Simulating the Right Mouse Button 1 From the Start menu click Programs gt USB_TOUCH gt PenMount gt RightButton gt Communication d WSB TOUCH sr Penmou
11. WINPAC_Utility 2 A warning pop up will be displayed asking you to confirm the uninstall request Click the Yes button to uninstall the driver Uninstall Drivers V104 7 Are vou uninstalling this drivers 3 Once the uninstallation process is complete a dialog will displayed requesting that you reboot the system Click the Yes button to reboot the WinPAC immediately or click NO if you intend to reboot at a later time Uninstall Grivers Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 51 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com 2 1 2 4 Other Windows CE5 0 Devices The driver can be obtained from Driver path CD name Driver WinCE V5 0 Other CE5 0 device TP 2070 T P 3080 For example TPM 4100_TP 4100 CD TP 2070 Driver WinCE V5 0 Other CE5 0 device TP 5120 T P 6150 TP 7170 or go to PenMount website to download the latest driver http www penmount com down_2 1 php Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 52 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com 2 2 Windows CE 6 0 This section describes how to install calibrate and uninstall the touch driver for the XP 8000 CE6 series and gives details of how to obtain drivers for other CE6 devices Touch Panel Monitor User Manual version 1 0 7 Last Revised
12. wants to use other com port please note the position of TX and RX of COM port About the pin assignment please refer to the user manual of the XP 8000 CE6 AAT XP 8341 CE6 1 Copy the driver from the CD ROM to the XP 8000 CE6 device The PenMount_Serial TOUCH_Vxx_yyyymmdd_XPAC_CE6 PM6000R CAB file can be obtained from Driver path Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 62 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com TP 2070 TP 3080 ODA AIG ENCE is B000 0E0 device For example TPM 4100_TP 4100 CD TP 2070 Driver WinCE V6 0 XP 8000 CE6 devicel TP 5120 TP 6150 TP 7170 Or go to the System Disk External device driver folder on the XP 8000 CE6 2 Double click the PenMount_Serial TOUCH_Vxx_yyyymmdd_XPAC_CE6 PM6000R CAB file Tips amp Warnings The driver cab file can only be used once If you attempt to use it to install driver a second time a warning dialog with a message similar to lt filename gt is not a valid Windows CE Setup file will be displayed advising that the setting has failed Please re download a new cab file to use Setup Failed The file System DiskiExternal device driver PenMount Serial CAB is not a valid Windows CE Setup file 3 Depending on the type of CPU one of two dialog windows will be displayed If the controller use the ATOM CPU Alternatively i
13. 00 series and the XP 8000 series Package List The shipping package includes the following items 1 TFT LCD Monitor 1 VGA cable 1 RS 232 cable 1 USB cable 4 Mounting clamps 4 Mounting Screws 1 Power supply 1 Companion CD containing software drivers and digital versions of the user manuals Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 6 Copyright 2012 ICP DAS Co Ltd All Rights Reserved D lt E mail service icpdas com 1 1 Features e Support resolution TP 2070 ra TP 3080 TPM 4100 TP 4100 800 x 600 TP 5120 TP 6150 1024 x 768 TP 7170 17 1280 x1024 e Full function OSD control keys for optimizing the display e Driver Support for Windows 2K XP Vista 7 XP Embedded WinCE 5 0 6 0 Linux e Wide operating temperature range TP 2070 TP 3080 TPM 4100 TP 4100 TP 5120 TP 6150 TP 7170 20 70 C e Aluminum front bezel design that is ideal for rugged applications e LED backlight technology e Supports the IP65 standard for protection against dust and water Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 7 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com 1 2 Specifications The table below is a summary of the specifications of the touch panel and lists the accessories that are supported by the touch panel Specifications Model TP 2070 Display 800 x 480 400 cd m2
14. 14 Page 20 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com ro ro amp ol Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 21 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com TP 4100 Unit mm Rear View Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 22 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com l l l l l 21494 l A A A A A A gt Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 23 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com TP 6150 Unit mm Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 24 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com CE E AO O O E CI E CI E E E CI O O E E E E DD E E E E E E E E E E E Ll a L n l L CE ER ee E E O E DCE OH PR E E E ER E E He E PE T 287 Recommended Panel Cut Out AA PRNO a Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 25
15. 2 03 27 File System Information Auto Executio Help arial Port Module EVVF Operation O Automatically run EWF Status when log on Windows EWF Control Write Protect has been disabled You must restart this computer for the changes to take effect Enable Disable x Warning You must restart this computer for the changes to take effect 2 From the Start menu click Programs gt PenMount Universal Driver gt Uninstall an Accessories k FA Microsoft SQL Server 2005 y Documents Ge PenMount Universal Driver PenMount Control Panel Programs ount Monitor Settings ss S Uninstall Search Help and Support Fun Windows Embedded Standard 3 Click Yes button Uninstall 2 Are You sure vou want to completely remove PenMount Universal Driver 2 1 0 234 and all of its components NENE No Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 81 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com 4 Click Yes button to reboot E PenMount Universal Driver 2 1 0 234 Uninstall P PenMount Universal Driver 42 1 0 234 was successfully removed from pour computer You need to reboot the system to finish the uninstall Reboot now a 5 After reboot executing XPAC Utility to enable EWF on desktop XPAC Utility 1 0 5 0 2012 03 27 File Help
16. 2 2 2 3 Uninstalling the XP 8000 CE6 67 2 2 2 4 Other Windows CE 6 0 Device 69 2 3 Windows XP Embedded 2 3 1 Universal Driver 2 3 1 1 Installation for XP 8000 71 2 3 1 2 Configuration for XP 8000 77 2 3 1 3 Uninstall for XP 8000 81 2 3 1 4 Other Windows XP Embedded Devices 83 2 4 Windows XP 7 ss A 84 2 4 1 Universal Driver 84 2 4 1 1 Installation 89 2 4 1 2 Configuring 89 2 4 1 3 Uninstall ooocccooo o A 91 Appendix A Revision History 93 Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 4 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com 1 Introduction This chapter provides an overview of the TPM 4100 TP 4100 TP 2070 T P 3080 T P 5120 TP 6150 TP 7170 and its components ve e Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 5 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com The TPM 4100 TP 4100 TP 2070 TP 3080 TP 5120 TP 6150 TP 7170 Panel Mount Monitor includes a standard TFT LCD screen with a rugged aluminum front bezel resolution and a wide operating temperature range The TPM 4100 TP 4100 TP 2070 T P 3080 TP 5120 TP 6150 TP 7170 is also guaranteed to integrate with ICP DAS PAC control systems such as WP 8000 series LinPAC 80
17. Description Contrast Adjusts the contrast of the monitor Brightness Adjusts the brightness of the monitor NN SP gh Image setting Auto config Press KJ to adjust automatically Phase Increase or decrease phase value Clock Increase or decrease pixel clock value Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 31 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com H position Move the screen left or right V position Moves the screen up or down Color setting NATIVE Color temperature 9300K Color temperature 6500K Color temperature USER Making adjustments to the R G B content OSD setting Language Support 8 languages Move the OSD position horizontally on the screen When the A button is pressed the OSD control menu will move to the right side of the screen Likewise when the Y button is pressed the OSD control menu will move to the left side OSD H Move the OSD position vertically on the screen When the A button is pressed the OSD control menu will move to the top side of the screen Likewise when the Y button is pressed the OSD control menu will move to the lower side OSD V TP 3080 TP 5120 TP 6150 TP 7170 support the following OSD menu i bap ps pm USM F Control Function 1 Turn on Turn off the power 2 PH OSD exit Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 32 Cop
18. Luminance Touch screen 4 wire analog resistive Light Transmission 80 500 1 140 120 20 000 Contrast ratio Viewing angle H V Backlight life hrs Touchscreen function Combo RS 232 amp USB interface Input signal VGA analog RGB MMI Man Machine Interface Functions Brightness Contrast Clock Phase Horizontal Position Vertical Position OSD control and Sharpness Power switch Power switch Yes LED indicators Power Display signal is detected Power 12 48 VDC 5 W Input range Power consumption Mechanical Plastic 213 mm x 148 mm x 44 mm Panel Mounting VESA 75 x 75 Mounting Front panel IP65 Environmental 20 70 10 90 RH non condensing Ss Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 8 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com EXE Display RA 167M Touch screen 5 wire analog resistive Light Transmission 80 MMI Man Machine Interface Functions Brightness Contrast Clock Phase Horizontal Position Vertical Position OSD control and Sharpness Power Mechanical Installation Panel Mounting VESA 75 mm x 75 mm 100 mm x 100 mm Mounting Environmental 10 90 RH non condensing Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 9 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com A A Di
19. P 7170 CD TP 2070 Driver WinCE V6 0 Other CE6 0 devicel or go to the PenMount website to download the latest driver http www penmount com down_2 1 php Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 60 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com 2 2 2 Serial Touch Driver Two serial touch drivers are available The first is for XP 8000 CE6 series modules of ICPDAS PAC controllers and the second is for other Windows CE6 0 systems XP 8000 CE6 series 1 Using ATOM CPU XP 8141 Atom CE6 XP 8341 Atom CE6 XP 8741 Atom CE6 XP 8147 Atom CE6 XP 8347 Atom CE6 XP 8747 Atom CE6 XP 8149 Atom CE6 XP 8349 Atom CE6 XP 8749 Atom CE6 2 Using LX800 CPU XP 8041 CE6 XP 8341 CE6 XP 8741 CE6 XP 8047 CE6 XP 8347 CE6 XP 8747 CE6 XP 8049 CE6 XP 8349 CE6 XP 8749 CE6 XP 8046 CE6 XP 8346 CE6 XP 8746 CE6 Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 61 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com 2 2 2 1 Installation for XP 8000 CE6 The following procedure describes how to install the PenMount Serial touch driver Note that the default COM Port for the touch driver is COM5 There is a RS 232 cable in the shipping package Sec 1 The user can directly use this cable to connect the monitor with COM5 of XP 8000 CE6 to use serial touch driver to do a touch operation by serial way If the user
20. P DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com 2 1 1 1 Installation for WinPAC 8000 and WinPAC 5000 The following procedure describes how to install the PenMount USB touch driver 1 Copy the driver from the CD ROM to the WinPAC The PenMount_USB_TOUCH_Vyyyymmdd CAB driver file can be obtained from Iname Driver path TP 2070 TP 3080 TP 5120 CD name Driver WinCE V5 0 WP 8000 and WP 5000 device TPM 4100_TP 4100 For example TP 6150 TP 7170 CD TP 6150 Driver WinCE V5 0 WP 8000 and WP 5000 device Or go to the System_Disk External_ device_driver folder on the WinPAC 2 Double click the PenMount_USB_TOUCH_Vyyyymmdd CAB file LE 4 2 xia B 7 els ala els elle als els os els I Egalax_Se Egalax_US ELO Serial ELO_USB PenMount PenMount Pa a PMGODO_S readme FOBx_ Win SB_TOUCH_ 20100526 3 Show one of two dialogs below Just click the OK button to continue installation Install ICP GJ System_Disk Already Installed ICPDAS USB PenMount is already installed Re install Name SA M Uai er Type 4 From the Start menu click Programs gt Open the WinPAC Utility and then click the Save and Reboot option from the File menu WInPAG Utility 2 0 2 7 aCA Help Configuration E Save and Reboot h gt Restore Default Settings Exit Touch Panel Monitor User Manual version 1 0 7
21. Please refer to the Step 8 of Sec 2 4 1 1 to detect again Simulating Right Mouse Button For details of how to configure right mouse button simulation please refer to the process describes in Simulating the Right Mouse Button in Sec 2 3 1 2 Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 90 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com 2 4 1 3 Uninstall The following procedure describes how to uninstall the PenMount universal touch driver 1 XP Start gt All Programs gt PenMount Windows Universal Driver gt Uninstall Win7 Control Panel gt Programs gt Programs and Features BS windows Messenger fg PenMount Windows Universal Driver ES sett 11 FE Uninstall Startup p Tour Windows xP 20 Files and Settings Tri SS Wizard Y Paint de PenMount Control Pa i amp Internet Explorer 32 Hit amp Internet Explorer 64 bit we msn 5 Outlook Express Fai Remote Assistance Windows Media Player Ss Windows Messenger All Programs Windows Movie Maker pe Log OFF o Turn OFF Computer t untitled Paint CIO Control Panel Programs Programs and Features v Search Programs and Features Control Panel Home Uninstall or change a program View installed updates To uninstall a program select it from the list and then click U
22. Programs gt PenMount Universal Driver gt PenMount Control Panel A Accessories G Microsoft SQL Server 2005 4 Documents d i PenMount Universal Driver l PenMount Control Panel pm PenMount Monitor 4 Uninstall Settings Search Help and Support Run y 7 T 0 47 5 fl Lu a Lu WI B 2 Check if the pattern PenMount 6000 USB or PenMount 6000 RS232 shows If yes select a device and click Configure button If no refer to Sec 2 3 1 1 PenMount Control Panel PenMount Control Panel Device Multiple Monitors Tools About Device Multiple Monitors Tools About Select a device to configure Select a device to configure Pe A E rA PenMount PenMount 6000 USB 6000 R Y cxtore Refresh ES Refresh Y x USB touch driver Serial touch driver 3 Click Standard Calibration to calibrate Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 77 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com O Device 0 PenMount 6000 USB Calibrate Setting About Click here td calibrate Standard Calibration Turn off EEPROM storage 4 Executing XPAC Utility to disable EWF to save setting on desktop XPAC Utility 1 0 5 0 2012 03 27 File Help System Information Auto Executio erial Port Module EWF Operation O
23. TPM 4100 TP 4100 TP 2070 TP 3080 TP 5120 TP 6150 TP 7170 Touch Panel Monitor User Manual su gg Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 1 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com gt Warranty All products manufactured by ICP DAS are under warranty regarding defective materials for a period of one year beginning from the date of delivery to the original purchaser Warning ICP DAS assumes no liability for any damage resulting from the use of this product ICP DAS reserves the right to change this manual at any time without notice The information furnished by ICP DAS is believed to be accurate and reliable However no responsibility is assumed by ICP DAS for its use nor for any infringements of patents or other rights of third parties resulting from Its use gt Copyright Copyright 2012 by ICP DAS Co Ltd All rights are reserved Trademarks Names are used for identification purposes only and may be registered trademarks of their respective companies Contact us lf you encounter any problems please feel free to contact us You can rely on ICPDAS for a prompt quick response Email service icpdas com Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 2 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com Table of Contents Table o
24. Windows Explorer _ XPAC_Utility 2 Follow the instruction on the screen to begin calibration You will be presented with one of two screens depending on the CPU you are using If you are using the LX800 SC CPU the screen will look like SCAN this lf you are using the ATOM CPU the screen gt will look like this S es Cor ee eos 2 By Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 65 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com Change the COM Port 1 From the Start menu click Programs gt Serial TOUCH gt PenMount gt SetCONW A Aa lt lt Calibration A cerdisp A drawderno E CA es Command Prompt i Le Favorites PEA islas E Documents Regedit Ly Settings P fa TaskManager a Windows Explorer Start yf MPAC_Utility 2 Just choose the COM port gt Click Set button gt Click Yes button to reboot the system The baudrate for the touch monitor is 19200 bps so please dont modify the baudrate of touch driver COM Port Changed Press es to take effect Simulating Right Mouse Button For details of how to configure right mouse button simulation please refer to the process describes in Simulating the Right Mouse Button in Sec 2 1 1 2 Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 66 Copyright 2012 ICP DAS
25. am Files x86 PenMount Windows Universal Driver Nullsoft Install System v2 46 Ge Desa 4 Click Finish button to reboot PenMount Windows Universal Driver V2 2 0 283 Win7 32 64 E lo Completing the PenMount Windows Universal Driver 2 2 0 283_ Win 32 6 4bit WHQL Uninstall Wizard Your computer must be restarted in order to complete the uninstallation of PenMount Windows Universal Driver V2 2 0 283 Win 32 64bit WHOL Do vou want to reboot nowy Reboot now O 1 want to manually reboot later lt Back Cancel Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 92 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com Appendix A Revision History Revision Date Description August 2012 1 0 3 September 2013 1 Modify specifications about TP 4100 TPM 4100 2 Modify the name of serial driver for WinPAC 8000 and WinPAC 5000 3 Add Tips amp Warnings to Step6 in Sec 2 3 1 1 TP 6150 1PM 6150 TP 3070 to TP 2070 1 0 7 May 2014 Delete related description of TPM 6150 Add related description of TP 3080 TP 5120 TP 7170 There are two kinds of OSD menu TP 4100 TPM 4100 TP 2070 use the same OSD menu TP 3080 TP 5120 TP 6150 TP 7170 use the other one The OS version 1710 and upward of WP 8x4x supports resolution 640X480 for TP 2070 The OS version 1300 and upward of WP 5x4x suppor
26. ance Windows Media Player 3 Windows Messenger All Programs D Windows Movie Maker P Log Orr oJ Turn OFF Computer E th touch Paint Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 87 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com b Device tab gt click Refresh button to search USB or serial touch screen monitor gt if search is successful PenMount 6000 USB or PenMount 6000 RS232 will show FenMount Control Panel Device Multiple Monitors Tools About Select device to configure FenMount 6000 USE USB touch Configure A PenMount Control Panel Device Multiple Monitors Tools About Select device to configure PenMount 6000 F Serial touch c If search is successful the USB or serial touch driver has been installed da Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 88 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com 2 4 1 2 Configuring Calibration 1 From the Start menu click All Programs gt PenMount Windows Universal Driver gt Utility gt PenMount Control Panel fl 23 Windows Messenger pr PenMount Windows Universal Driver F y Utility 5 PenMount Control Panel pa E Startup Ef Uninstall E PenMount Gesture Tour Windows XP Internet Explorer 32 b
27. and Support Run Windows Embedded Standard Shut Down b Device tab click Refresh button to search USB or serial touch screen monitor gt if search is successful PenMount 6000 USB or PenMount 6000 RS232 will show Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 75 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com PenMount Control Panel Device Multiple Monitors Tools About Select a device to configure USB touch PenMount 6000 USB PenMount Control Panel Configure 4 E Device Multiple Monitors Tools About Select a device to configure PenMount 6000 R c If search is successful USB or serial touch driver has been installed 10 Executing XPAC Utility to enable EWF on desktop XPAC Utility 1 0 5 0 2012 03 27 File Help System Information Auto Execution ulti serial Port Module O Automatically run EWF Status when Ilog on Windows EME Contral Write Protect enable Success You must restart this computer for the changes to take effect Enable Disable Warning 11 Restart XP 8000 Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 76 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com 2 3 1 2 Configuration for XP 8000 Calibration 1 From the Start menu click
28. are installing for this hardware PenMount 6000 Serial has not passed Windows Logo testing to verify its compatibility with Windows lt P Tellme why this testing is important Continuing your installation of this software may impair or destabilize the correct operation of your system either immediately or in the future Microsoft strongly recommends that you stop this installation now and contact the hardware vendor for software that has passed Windows Logo testing d Continue Anyway STOP Installation Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 74 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com 7 Click Finish button 6 PenMount Universal Driver 2 1 0 234 Setup Completing the PenMount Universal Driver 2 1 0 234 Setup Wizard PenMount Universal Driver 2 1 0 234 has been installed on your computer Click Finish to close this wizard 8 Restart XP 8000 9 Connect USB or serial cable to XP 8000 USB and serial can not be used simultaneously lf the USB or serial touch doesn t work please follow the steps below a From the Start menu click Programs gt PenMount Universal Driver gt PenMount Control Panel i Accessories ig Programs FA Microsoft SQL Server 2005 2 Documents F PenMount Universal Driver PenMount Control Panel gt pm PenMount Monitor Uninstall Settings Search Help
29. e C D 3 Double click Setup exe in the driver s folder Sep exe Setup 4 Click Next button to continue installation 6 PenMount Universal Driver 2 1 0 234 Setup Welcome to the PenMount Universal Driver 2 1 0 234 Setup Wizard This wizard will guide you through the installation of PenMount Universal Driver 2 1 0 234 It is recommended that you close all other applications before starting Setup This will make it possible to update relevant system files without having to reboot your computer Click Next to continue So Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 72 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com 5 Click I Agree button 6 PenMount Universal Driver 2 1 0 234 Setup License Agreement Please review the license terms before installing PenMount Universal Driver 2 1 0 234 Press Page Down to see the rest of the agreement PLEASE READ THE LICENSE AGREEMENT Pentiount touch screen driver software is only for using with Penkfount touch screen controller or control board Any person or company using a Pen fount driver on any piece of equipment which dees not utilize an PenMount touch screen controller will be prosecuted to the full extent of the law A If you accept the terms of the agreement click I Agree to continue You must accept the agreement bo install PenMount Universal Driver 2 1 0 234
30. e drivers An outline of the folder structure is illustrated below CD Model Win _XP_7 Touch Driver for Windows 2K XP 2003 2008 Vista 7 XP 8000 device Touch Driver for the XP 8000 series Other XP Embedded device Touch Driver Other CE5 0 device WP 8000 and WP 5000 device Other CE6 0 device XP 8000 CE6 device Touch Driver for the XP 8000 CE6 series Touch Driver Touch Driver for the WP 8000 and WP 5000 series Touch Driver Documents Touch_Panel_User_Manual_vXXX pdf The Model of the CD Model represents TPM 4100_TP 4100 TP 2070 TP 6150 etc For example CD TPM 4100_TP 4100 or CD TP 2070 Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 30 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com 1 6 System Setup This section gives details regarding system configuration and adjustment and mounting options 1 6 1 System Configuration There are two kinds of OSD menu in the following description TP 2070 TP 4100 TPM 4100 support the following OSD menu Control Function Adjust V Position H Position Clock and Clock and Clock Phase Turns OSD main menu on or off 4 Selects adjustment item Selects adjustment item counter clockwise OOOO Decreases the value of the adjustment item 1 Increases the value of the adjustment item 2 3 4 5 6 2 Enter the adjustment item OSD Menu Functions Control
31. ess Contrast Phase Horizontal Position Vertical Position and OSD control sharpness Power Mechanical Panel Mounting VESA 75mm x 75mm 100mm x 100mm Mounting Environmental 10 90 RH non condensing Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 12 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com XA Display 140 130 Backlight life hrs Touchscreen function Combo RS 232 amp USB interface Input signal VGA analog RGB MMI Man Machine Interface Functions Brightness Contrast Phase Horizontal Position Vertical Position and OSD control sharpness Power Mechanical Panel Mounting VESA 75mm x 75mm 100mm x 100mm Mounting Front panel IP65 Environmental Ambient relative humidity 10 90 RH non condensing Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 13 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com 1 3 Dimension TP 2070 Unit mm Bottom View 130 7 Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 14 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com FE 133 a A _ Recommended Panel Cut Out Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 15 Copyright 2012 ICP DAS Co Ltd
32. f Content uu cccccccccccecccccccceceeneeneuneeneeas 1 INTFOQUCUON 8 1 1 FO Sui O 1 2 Specifications scissa RS 1 3 DIMENSION ns cor anono corzo A 1 4 VO interfaces 1 5 Companion CD ooocccnccnccnccnncnonncnnnnnnnnnnncnonnnononenenoness 1 6 System Setup 1 6 1 System Configuration 1 6 2 Panel Mounting 36 2 Touch Driver Setup 38 2 1 Windows CE 5 0 39 2 1 1 USB Touch Driver 40 2 1 1 1 Installation for WinPAC 8000 and WinPAC 5000 41 2 1 1 2 Configuration for WinPAC 8000 and WinPAC 5000 42 2 1 1 8 Uninstalling the WinPAC 8000 and WinPAC 5000 44 2 1 1 4 Other Windows CE5 0 Devices 45 2 1 2 Serial Touch Driver 46 2 1 2 1 Installation for WinPAC 8000 and WinPAC 5000 47 2 1 2 2 Configuration for WinPAC 8000 and WinPAC 5000 49 2 1 2 3 Uninstalling the WinPAC 8000 and WinPAC 5000 51 2 1 2 4 Other Windows CE5 0 Devices 52 222 WINIOWS UE DD caen 53 2 2 1 USB Touch Driver 54 2 2 1 1 Installation for XP 8000 CE6 55 Y 2 2 1 2 Configuration for XP 8000 CE6 57 Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 3 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com 2 2 1 3 Uninstalling the XP 8000 CE6 58 2 2 1 4 Other Windows CE6 0 Devices 60 2 2 2 Serial Touch Driver 2 2 2 1 Installation for XP 8000 CE6 62 2 2 2 2 Configuration for XP 8000 CE6 65
33. f the controller the following will be displayed use the LX800 CPU the following will be displayed Install ICPDAS S Install ICPDAS Serial PenMount eres GJ My Device gt Application Data O My Documents D Application Data O Temp a O My Documents E Network Network O Program Files OG Windows ES Control Panel D Program Files System_Disk Name MEE MEE Click the OK button to continue with the installation Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 63 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com 4 Once the installation has been completed a dialog will be displayed advising that the system needs to be rebooted Click the OK button to reboot the XP 8000 CE6 Install complete Press OE button to reboot the system and the settings will take effect Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 64 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com 2 2 2 2 Configuration for XP 8000 CE6 Calibration 1 From the Start menu click Programs gt Serial TOUCH gt PenMount gt Calibration EEES PenMourt Calibration g cerdisp ai BE Command Prompt gt RiohtButton CECI ee DCON_CE XP EJ setcom Le Favorites CA isqhwas y Documents RegEdit Cr Settings 3 TaskManager Run 9
34. h o Help and Support Fun Le m a 42 La az q TT qu LILI O q Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 79 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com 2 Click Right Button Icon PenMount Control Panel Device Multiple Monitors Tools About Test by drarwing on the touch screen Gra co Turn ON OFF Advanced Calibration Mode Advanced Calibration show Hide the icon For switching buttons Right Button Icon Desktop f System Tray Back to Default OK 3 Show a screen below Left picture gt Click the mouse gt Turn into right D mm DI 4 Click any object Click My computer to test if the Right Button Icon function work If the screen below shows the Right Button Icon function picture works Arrange Icons Ey P Refresh Me Properties 5 You can simulate the operation of right mouse button to repeat step3 and step4 for any object Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 80 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com 2 3 1 3 Uninstall for XP 8000 The following procedure describes how to uninstall the PenMount universal touch driver 1 Executing XPAC Utility to disable EWF to start to save setting XPAC Utility 1 0 5 0 201
35. h Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 47 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com Iname Driver path CD name Driver WinCE V5 0 WP 8000 and WP 5000 device TP 2070 T P 3080 TP 5120 TPM 4100_TP 4100 TP 6150 For example TP 7170 CD TP 6150 Driver WinCE V5 0 WP 8000 and WP 5000 device Or go to the System_Disk External_device_driver folder on the WinPAC 2 Double click the PenMount Serial TOUCH Vyyyymmdd PM6000R CAB file CE I Egalax_Se Egalax_US ELO Serial ELG USB PenMount PenMount PenMount Sais readme 756x Win al_TOUCH_Y 20100614 3 Show one of two dialogs below Just click OK button to continue installation Already Installed l k yx ICPOLS SERIAL PMB000 is already installed Re installe 4 From the Start menu click Programs gt 0Open the WinPAC Utility and then click the Save and Reboot option from the File menu WinPAG Utility 2 0 2 7 aF Help Configuration Save and Reboot Restore Default Settings Exit Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 48 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com 2 1 2 2 Configuration for WinPAC 8000 and WinPAC 5000 Calibration 1 From the Start menu click Programs gt Se
36. hts Reserved gt lt E mail service icpdas com 2 4 1 1 Installation The following procedure describes how to install the PenMount universal touch driver 1 Copy the driver from the CD ROM to your device The touch driver can be obtained from Iname Driverpatt TP 2070 TP 3080 CD name Driver Win_XP_7 TPM 4100_TP 4100 For example TP 5120 TP 6150 TP 7170 CD TP 2070 Driver Win_XP_7 2 Connect USB or serial cable to your device USB and serial can not be used simultaneously 3 Executing Setup exe 4 Click Next button to continue installation PenMount Windows Universal Driver V2 2 0 283 Win7 32 64 2 Welcome to the PenMount Windows Universal Driver V2 2 0 283_ Win 32 6 4bit WHQL Setup Wizard This wizard will guide you through the installation of PenMount Windows Universal Driver W2 2 0 283 04 in7 32 64bit WHOL It is recommended that you close all other applications before starting Setup This will make it possible to update relevant system files without having to reboot your computer Click Next to continue Ge 5 Click I Agree button PenMount Windows Universal Driver V2 2 0 283 Win7 32 64 License Agreement Please review the license terms before installing PenMount Windows Universal Driver Y2 2 0 283 Win7 32 64bit WHOL Press Page Down to see the rest of the agreement PLEASE READ THE LICENSE AGREEMENT PenMount touch screen driver software i
37. indows Universal Driver V2 2 0 283 Win 32 64bik WHOL has been installed on your computer Click Finish to close this wizard lt Back Cancel Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 86 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com Tips amp Warnings When the system first detects a touch monitor a screen appears that shows Unknown Device Do not use this hardware wizard Press Cancel Found New Hardware Wizard Welcome to the Found New Hardware Wizard This ward helos you install sobrere for Unknown li your hardware came with an installation CD 2 o floppy disk insert now Wiha do vou want Ihe wzatd lo do D Install the salwar automaticaly Recommended Install from a let or specilic location Advanced Click Next to continue 8 Ifthe USB or serial touch doesn t work following the steps below a From the Start menu click All Programs gt PenMount Windows Universal Driver gt Utility gt PenMount Control Panel 23 Windows Messenger Tour windows XP F fag PenMount Windows Universal Driver fgg Utility J y PenMount Control Panel amp Internet Explorer 32 bit M Penmount Monitor B PenMount Gesture a Internet Explorer 64 bit we msn 5 Outlook Express Files and Settings Tr Wizard Y Paint 7 ge Remote Assist
38. it MI Penmount Monitor a a Internet Explorer 64 bit Files and Settings Tr Wizard we msn 1 6 Outlook Express Paint Fa Remote Assistance Windows Media Player a Windows Messenger All Programs D Windows Movie Maker P Log OFF oJ Turn OFF Computer E Ws kouch Paint 2 Check if the pattern PenMount 6000 USB or PenMount 6000 RS232 shows If yes select a device and click Configure button If no refer to Sec 2 4 1 1 PenMount Control Panel PenMount Control Panel Device Multiple Monitors Tools About Device Multiple Monitors Tools About Select a device to configure Select a device to configure L N L PenMount 6000 USB Refresh USB touch driver Serial touch driver 3 Click Standard Calibration to calibrate Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 89 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com Pd Device 0 PenMount 6000 USB Calibrate Setting Edge Compensation About Advanced Mode 5 Plot calibration data Standard Calibration Advanced Calibration Turn off EEPROM storage Click here to calibrate Change the COM Port For serial touch driver Methodl The touch driver will detect all com port to find what com port connects to serial touch screen monitor automatically when PC reboots every time Method2
39. l Monitor User Manual version 1 0 7 Last Revised June 2014 Page 56 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com 2 2 1 2 Configuration for XP 8000 CE6 Calibration 1 From the Start menu click Programs gt USB_TOUCH gt PenMount gt Calibration gt Communication m USB TOUCH W Penmount A cerdisp E He Command Prompt gt RightButton CERCA OCON_CE_xP ve Favorites A isqlwas Documents RegEdit Cr Settings la TaskManager CF Run Windows Explorer F vy XPAC_Utility 2 Following the instructions on the screen to begin calibration a Calibration Mode Select 1 6 Click on the preferred mode Wait 6 seconds to 9 Points 4 Points 9 Points 16 Points JL der 2 26 an 3s Ss PenMount Calibration Simulating the Right Mouse Button N e Y For details of how to simulate right mouse button functions please refer to th process described in Simulating the Right Mouse Button in Sec 2 1 1 2 Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 57 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com 2 2 1 3 Uninstalling the XP 8000 CE6 The following procedure describes how to uninstall the PenMount USB touch driver 1 From the Start menu click Settings gt Control Panel Programs ie Favorites E D
40. ndows CE5 0 systems WP 8000 series WP 8131 WP 8431 WP 8831 WP 8141 WP 8441 WP 8841 WP 8137 WP 8437 WP 8837 WP 8147 WP 8447 WP 8847 WP 8139 WP 8431 WP 8839 WP 8141 WP 8441 WP 8849 WP 8136 WP 8431 WP 8836 WP 8141 WP 8441 WP 8846 WP 5000 series WP 5141 WP 5441 OD WP 5149 WP 5449 OD WP 5147 WP 5447 OD WP 5146 WP 5446 OD Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 46 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com 2 1 2 1 Installation for WinPAC 8000 and WinPAC 5000 The following procedure describes how to install the PenMount serial touch driver Note that the default COM port for serial touch driver is COM4 There is a RS 232 cable in the shipping package Sec 1 The user can directly use this cable to connect the monitor with COM4 of WinPAC 8000 to use serial touch driver to do a touch operation by serial way If the user wants to use other com port please note the position of TX and RX of COM port About the pin assignment please refer to the user manual of the WinPAC 8000 Warning WP 5141 The WinPAC 5000 series doesn t include a COM4 so please refer to Changing the COM Port in Sec 2 1 2 2 for details of how to change the COM Port to the specified COM Port po li Es ii 1 Copy the driver from the CD ROM to the WinPAC N The PenMount Serial_TOUCH_Vyyyymmdd PM6000R CAB driver file can be obtained from Touc
41. ninstall Change or Repair fa Turn Windows features on or Organize Uninstall Change A Name Publisher Installed On A Adobe Flash Player 10 ActiveX Adobe Systems Incorporated 2010 3 8 E PenMount Windows Universal Driver V2 2 0 282 Min anMaour 2012 5 11 4 Ta c23 PenMount e a 5 2 Click Next button Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 91 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com SF PenMount Windows Universal Driver V2 2 0 283 Win7 32 64 2 5 Xx Welcome to the PenMount Windows Universal Driver Y2 2 0 283 Win 32 64bit WHQL Uninstall Wizard This wizard will guide you through the uninstallation of PenMount Windows Universal Driver 42 2 0 283 04 in7 32 64bit WHOL Before starting the uninstallation make sure PenMount Windows Universal Driver 2 2 0 283 Win 32 64bit WHOL is not running Click Next to continue Cu 3 Click Uninstall button FF PenMount Windows Universal Driver V2 2 0 283 Win7 32 64 E O 163 Uninstall PenMount Windows Universal Driver Y2 2 0 283 Win7 32 64bit Y Remove PenMount Windows Universal Driver V2 2 0 283 Win7 32 64bit WHQL from your computer PenMount Windows Universal Driver 2 2 0 283 Win 32 64bit WHQL will be uninstalled From the Following folder Click Uninstall to start the uninstallation Uninstalling from C Progr
42. nt ME command Prompt Internet Explorer de Favorites ZY islas E Documents TF Microsoft WordPad Settings 40 Regview Help a TaskMigr Run a Windows Explorer 20 virtual Ol WINPAC Utility 4 Calibration lan Programs 7 RightButton 2 Show a screen below Left picture gt Click the mouse gt Turn into right picture RB n RB ecome Click the mouse des gt E gt 3 Click any object Click My device to test if the function of RightButton works If the screen below shows the function of RightButton works J y O H er Cut Copy Delete Rename Properties 4 The operation of the right mouse button can be simulated by repeating Step 2 and Step 3 for any object N Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 43 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com 2 1 1 3 Uninstalling the WinPAC 8000 and WinPAC 5000 The following procedure describes how to uninstall the PenMount USB touch driver 1 From the Start menu click Programs gt USB_TOUCH gt PenMount gt Uninstall gt Communication eee A 4 Calibration HE Command Prompt E Internet Explorer Es isqhw35 EF Microsoft WordPad Si Review Fa TaskMgr ae Windows Explorer a Y virtual UD WINPAC_Utility Gi Programs i Fav
43. ocuments etwork and Dial up Connections Taskbar and Start Menu 2 Double click the Remove Programs icon and select ICPDAS USB PenMount from the Programs panel in the Remove Programs dialog box and then click the Remove button When the warning pop up click Yes button to permanently uninstall the driver F Pi i x h y b A 6 5 8 Bs Vo 5 S 3 oO El Certificates Date Time Device Dialing Display Input Panel Keyboard Mouse Network and Owner Password Pr Management Dial up Co conne Storage System Manager remove a program select it from the list and then select Remove ite Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 58 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com 3 Once the uninstallation process is complete a dialog will be displayed requesting that you reboot the system Click the Yes button to reboot immediately or click the No button if you intend to reboot at a later time Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 59 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com 2 2 1 4 Other Windows CE6 0 Devices The driver can be obtained from Driver path TP 2070 T P 3080 CD name Driver WinCE V6 0 Other CE6 0 device TPM 4100_TP 4100 For example TP 5120 TP 6150 T
44. orites Ey Documents e Settings Help 3 RUN 2 warning pop up will be displayed asking you to confirm the uninstall request Click the Yes button to uninstall the driver Uninstall Drivers 9 Are you uninstalling this drivers 3 Once the uninstallation process is complete a dialog will displayed requesting that you reboot the system Click the Yes button to reboot the WinPAC immediately or click NO if you intend to reboot at a later time Uninstall Drivers E Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 44 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com 2 1 1 4 Other Windows CE5 0 Devices The driver for use with other windows CE5 0 devices can be obtained from Driver path CD name Driver WinCE V5 0 Other CE5 0 device For example CD TP 6150 Driver WinCE V5 0 Other CE5 0 device TP 2070 T P 3080 TP 5120 TPM 4100_TP 4100 TP 6150 TP 7170 or go to the PenMount website to download the latest driver http www penmount com down 2 1 php Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 45 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com 2 1 2 Serial Touch Driver Two serial touch drivers are available The first is for WP 8000 series modules and WP 5000 series modules of ICPDAS PAC controllers and the second is for other Wi
45. pyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com ju o O gt O This chapter provides a ovet that describes the steps required for installing uninstalling and configuring the touch driver Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 38 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com 2 1 Windows CE 5 0 This section describes how to install calibrate and uninstall the touch driver for the WP 8000 series and WP 5000 series and gives details of how to obtain drivers for other CE5 devices Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 39 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com 2 1 1 USB Touch Driver Two USB touch drivers are available The first is for WP 8000 series modules and WP 5000 series modules of ICP DAS PAC controllers and the second is for other Windows CE5 0 systems WP 8000 series WP 8131 WP 8431 WP 8831 WP 8141 WP 8441 WP 8841 WP 8137 WP 8437 WP 8837 WP 8147 WP 8447 WP 8847 WP 8139 WP 8431 WP 8839 WP 8141 WP 8441 WP 8849 WP 8136 WP 8431 WP 8836 WP 8141 WP 8441 WP 8846 WP 5000 series WP 5141 WP 5441 OD WP 5149 WP 5449 OD WP 5147 WP 5447 OD WP 5146 WP 5446 OD Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 40 Copyright 2012 IC
46. r XP 8000 The following procedure describes how to install the PenMount universal touch driver There is a RS 232 cable in the shipping package Sec 1 The user can directly use this cable to connect the monitor with COM5 of XP 8000 to use universal touch driver to do a touch operation by serial way If the user wants to use other com port please note the position of TX and RX of COM port About the pin assignment please refer to the user manual of the XP 8000 BAS XP 8341 COM5 XP 8341 Atom eo 1 Copy the driver from the CD ROM to the XP 8000 SS The PenMount Windows Universal Driver Vx x x x folder can be obtained fro ta Driver path TP 2070 TP 3080 CD name Driver Win_XP_Embedded XP 8000 devicel Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 71 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com TPM 4100_TP 4100 For example TP 5120 TP 6150 TP 7170 CD TP 2070 Driver Win_XP_Embedded XP 8000 device 2 Executing XPAC Utility to disable EWF on desktop B PenMount Windows Universal Driver 2 1 0 234 XPAC Utility 1 0 5 0 2012 03 27 File Help system Information Auto Execution EWF Operation J Multi serial Port Module O Automatically run EWF Status when log on Windows EWE Control VWrite Protect has been disabled You must restart this computer for the changes to take effect Enable Disabl
47. rial TOUCH gt PenMount gt Calibration CESEN le PenMoun al FE Command Prompt P DrawbDerna A lan Programs Internet Explorer 7 RightButtan gY isqlw35 E sercom E Documents EF Microsoft WordPad O Uninstall Lr Settings ef Regview Help a TaskMar Run E Windows Explorer 27 V Virtual Ch WINPAC Utility 2 Follow the instruction on the screen to begin calibration Calibration Mode Select Click on the preferred mode Wait 4 seconds to 9 Points 4 Points av Y PenMount Calibration Je Lar 7 34 PM LA 5 3 Once calibration has been completed from the Start menu click Programs gt Open the WinPAC Utility and then click the Save and Reboot option from the File menu WinPAG Utility 2 0 2 7 1139 Help Configuration Eo Save and Reboot k 2 gt Restore Default Settings Exit i LAS Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 49 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com Changing the COM Port 1 From the Start menu click Programs gt Serial_ TOUCH gt PenMount gt SetCONMW CE ee A 7 Calibration De ES Command Prompt A DrawDema CEE internet Explorer gt RightButton de Favorites isqwas Ca Documents WF Microsoft WordPad en Settings SH Regview Help E TaskMoar Run 2 Windows Explorer 27 V Virtual CI WINPAC Utili
48. s only for using with PenMount touch screen controller or control board Any person or company using a PenMount driver on any piece of equipment which does not utilize an PenMount touch screen controller will be prosecuted to the full extent of the law If you accept the terms of the agreement click I Agree to continue You must accept the agreement to install PenMount Windows Universal Driver 42 2 0 283 Win 7 32 64bit WHQL MT QT ET Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 85 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com 6 Click Install button to install driver PenMount Windows Universal Driver V2 2 0 283 Win7 32 64 2 51 6X Choose Install Location Choose the Folder in which Eo install PenMount Windows Universal Driver Y2 2 0 283 0407 32 64bit WHOL Setup will install PenMount Windows Universal Driver V2 2 0 283 in 32 64bit WHOL in the Following Folder To install in a different Folder click Browse and select another Folder Click Install to shart the installation Destination Folder Cu Program Files x86 PenMount Windows Universal Driver Space required 0 0KB Space available 26 066 Nullsoft Install System ve 46 EE Less rai Plena nn 7 Click Finish to finish installation Completing the PenMount Windows Universal Driver Y2 2 0 283 Win 7 32 64bit WHQL Setup Wizard PenMount W
49. splay Luminance aeuchcoreen 5 wire analog resistive Light Transmission 80 Light Transmission 80 Contrast ratio Viewing angle H V Backlight life hrs Touchscreen function Input signal MMI Man Machine Interface Functions Brightness Contrast Clock Phase Horizontal Position Vertical Position OSD control and Sharpness Power switch LED indicators Power Display signal is detected Power Input range 12 48 VDC Power consumption Mechanical Panel Mounting VESA 75 x 75 Mounting Environmental 10 90 RH non condensing Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 10 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com EAT A Display RA 167M Touch screen 5 wire analog resistive Light Transmission 80 MMI Man Machine Interface Functions Brightness Contrast Clock Phase Horizontal Position Vertical Position OSD control and Sharpness Power Mechanical Installation Panel Mounting VESA 75 mm x 75 mm 100 mm x 100 mm Mounting Environmental 10 90 RH non condensing Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 11 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com EXE A Display Touchscreen function Combo RS 232 amp USB interface Input signal VGA analog RGB MMI Man Machine Interface Functions Brightn
50. ts resolution 640X480 for TP 2070 TP 6150 cancels the power ANS The function is moved to OSD me Wu Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 93 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com
51. ty 2 Inthe pop up dialog select the COM Port you wish to use as default and click the Set button to save the changes Set COM Port PenMount PM6O COP Port 3 From the Start menu click Programs gt 0Open the WinPAC Utility and then click the Save and Reboot option from the File menu WinPAG Utility 2 0 2 7 AN Help Configuration Save and Reboot b o a As Restore Default Settings Exit 4 Disconnect the cable from the current COM Port and reconnect it to the specified COM Port Simulating the Right Mouse Button N the For details of how to configure right mouse button simulation please refer to process describes in Simulating the Right Mouse Button in Sec 2 1 1 2 Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 50 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com 2 1 2 3 Uninstalling the WinPAC 8000 and WinPAC 5000 The following procedure describes how to uninstall the PenMount serial touch driver 1 From the Start menu click Programs gt Serial_ TOUCH gt PenMount gt Uninstall gt Communication d CR meee A 4 Calbration N E ME command Prompt FP DrawDerno lan Programs Internet Explorer RightButton ean isqlhuw3s E Documents BF Microsoft WordPad Gr Settings Si Regview Help E TaskMoar Run 2 Windows Explorer 7 Y virtual Ch
52. x4x Atom CE6 60 70 75 85 800 x 600 60 70 75 85 640 x 480 XP 8x4x 1024 x 768 800 x 600 XP 8x4x CE6 1290 x 1024 TP 2070 not support 1152 x 864 TP 4100 TPM 4100 60 70 75 1024 x 768 800 x 600 60 70 75 Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 34 60 70 75 85 Don t care Don t care Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com The following display modes are supported for other devices Vert Sync 640 x 480 31 4 KHz 31 4 KHz 99 9 Hz 37 5 KHz 720 x 400 31 4 KHz 800 x 600 35 1 KHz 96 2 Hz 37 8 KHz 60 3 Hz 46 9 KHz 75 Hz 1024 x 768 60 Hz 56 4 KHz 70 Hz 60 0 KHz Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 35 Copyright 2012 ICP DAS Co Ltd All Rights Reserved D lt E mail service icpdas com 1 6 2 Panel Mounting Insert the mounting brackets ASON Screw the mounting bracket 2 to the unit Eight locations are available for attaching four mounting clamps to secure the unit Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 36 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com Panel thickness up to 6 mm Refer to Sec 1 3 for default information regarding the dimensions of the panel Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 37 Co
53. yright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com 3 Shift the icon to the left side or shift it down 4 Q Shift the icon to the right side or shift it up 5 Mi 1 Enter the OSD menu 2 Enter the adjustment item 6 Executing auto adjustment Data and Power LED The Data LED and Power LED are situated in the top right hand corner Power Data LED When the LED is green it indicates that there is no display signal Power LED When the LED is red it indicates that the power is on When the LED is not illuminated it indicates that either the power is off or the power supply is not connected Display Modes The following display modes are supported for WP 8000 and XP 8000 series Platform Supported Resolution Supported Vert Sync Hz WP 8x4x 800 x 600 55 8 56 6 Touch Panel Monitor User Manual version 1 0 7 Last Revised June 2014 Page 33 Copyright 2012 ICP DAS Co Ltd All Rights Reserved gt lt E mail service icpdas com TP 6150 55 8 640 x 480 Dont care TP 2070 Supported by the WP 8x4x OS version 1710 and upward WP 8x3x 1024 x 768 60 70 75 800 x 600 640 x 480 WP 5x4x 800 x 600 640 x 480 XP 8x4x Atom 1280 x 720 1024 x 768 800 x 600 1024 x 768 TP 6150 60 75 60 72 75 TP 6150 60 72 96 60 62 70 72 75 TP 6150 72 55 8 56 6 Don t care TP 2070 Supported by the WP 5x4x OS version 1300 and upward Don t care Don t care Don t care XP 8
Download Pdf Manuals
Related Search
Related Contents
Achats Groupés - Olympique Cesson Escrime Rennes-Est Wooster Pro 0H21180020 Installation Guide Heat Pure - Van Raemdonck Owner`s Manual Operator`s manual Manual d`utilisation Manual de Bedienungsanleitung/Garantie HTD 3243 PROFI SDS ダウンロード(213 KB) Untitled - Fédération Léo Lagrange Copyright © All rights reserved.