Home

ID78K0R-QB 78K0R Integrated Debugger

image

Contents

1. ZBG CD 07 0054 August 27 2007 Addition of restrictions No 20 to No 22 Addition of specification No 4 ZBG CD 08 0025 June 25 2008 Addition of restrictions No 23 and No 24 Addition of specifications No 5 to No 10 ZBG CD 09 0044 July 31 2009 Addition of restrictions No 25 and No 26 ZBG CD 10 0021 May 12 2010 Addition of restriction No 27 ZBG CD 10 0021 Attachment 1 12 1 Usage Restrictions This section describes the restrictions on using the ID78KOR QB The item numbers are the same as those described in 78KOR Integrated Debugger ID78KOR QB V3 60 Operating Precautions ZUD CD 09 0156 List of usage restrictions Usage Restrictions Affected Product V3 20 V3 30 V3 40 V3 50 sa 60 1 Sawee pam annot pe ades sven adic wig PME Gommon L s L sf xf 2_ Restriction on redraw o OED EATE Symbols with a func var format cannot be converted Common Described in the user s manual EE addresses 4 Searching fails in the Assemble window Common x x oO Lele Gl Kd window 7 eer foe fe impossible EA Invalid values are displayed in the Memory window Common x 0 0 Ea Restriction on hardware break before execution IECUBE Hx 204 oo ie Restrictions on coverage measurement IECUBE ee se 1 ee Laer wee lal e aaan Ball all A used E efter specified for an odd address in byte units 42 Restrictions on software break Restrictions on software break points sid MINICUBE2 x o
2. be specified for variables other than global variables Workaround To specify an access breakpoint to a static variable in a function use the Event dialog box while the current PC line is in that function To specify an access breakpoint to a static variable in a file use the Event dialog box while the current PC line is in that file Correction This issue has been corrected in V3 40 Specifying access breakpoints in the Watch and Source windows is now available for static variables in a function or a file Specifying access breakpoints in the Watch window is now available only for static variables registered in the Add Watch dialog box in the following formats e Static variables in a function file name function name tvariable name e Static variables in a file file name variable name No 14 Restrictions on adding SFRs to Add I O Port dialog box lt Common gt Description The following restrictions apply when adding SFRs to the Add I O Port dialog box dialog box used when an SFR name is redefined with another name in a C source 1 Ifa R W attribute SFR is added as a W attribute register with another name the SFR is added to the Add Watch window and its value is changed in the Watch window values displayed in the SFR window are not updated 2 Adding SFRs for the 2nd SFR area is not available if attempted an error occurs 3 If an SFR that satisfies the conditions below is added the SFR is added but an error occurs when an att
3. is now displayed as a message Fb035 Return execution from present PC position cannot be performed Perform step wise execution once and then Return Out No 20 Restriction on BCD correction result register lt Common gt Description When stepping through the code of an addition or subtraction instruction the value in the BCD correction result register BCDADJ becomes invalid In addition the value in register A is not corrected in decimal units when using MINICUBE2 Workaround There is no workaround Correction This issue has been corrected in V3 40 No 21 Restriction on Code Coverage window lt IECUBE gt Description The value 0 0 is displayed in the Coverage column on the Interrupt tab in the Code Coverage window regardless of whether an interrupt has occurred or not In addition is displayed in the Status column regardless of whether interrupt servicing is specified to be used or not gt Code Covreraece Seles Load Module alm Total Coverage CRY 470 Refresh Close Function Section Interrupt 0 maskable maskable 0 maskable 0 Workaround The Interrupt tab is used to check whether an interrupt has occurred but this can also be checked by referring to the Function tab to check the coverage of the function corresponding to the interrupt e When 0 0 is displayed in Coverage No interrupt has occurred e When a value other than 0 0 is displayed in Coverage An interrupt
4. Microcontroller Technical Information Document No ZBG CD 10 0021 1 1 Date issued May 12 2010 MCU Tool Product Marketing Department MCU Software Division MCU Business Unit ID78KOR QB 78KOR Integrated Debugger Issued by Usage Restrictions Related documents Renesas Electronics Corporation ID78KOR QB Ver 3 60 Integrated Debugger Notification Usage restriction Operation User s Manual U19613EJ1VOUMOO 1st edition classification Upgrade Document modification 78KOR Integrated Debugger ID78KOR QB V3 60 E Operating Precautions ZUD CD 09 0156 m Other notification 1 Affected product Affected Version ID78KOR QB 78KOR integrated debugger V3 60 or earlier 2 New restriction New restriction No 27 has been added See the attachment for details 3 Workarounds See the attachment for details 4 Modification schedule Products in which restriction No 27 is corrected will be posted on the Development Tools Download webpage on May 13 2010 ID78KOR QB V3 61 Note that this schedule is subject to change without notice For the detailed release schedule of modified products contact a Renesas Electronics sales representative 5 List of restrictions See the attachment 6 Document revision history 78KOR Integrated Debugger ID78KOR QB Usage Restrictions Document Number ZBG CD 07 0010 January 18 2007 Addition of restrictions No 8 to No 19 Addition of specifications No 1 to No 3
5. No 10 Operation becomes invalid if a specific stack area is used lt MINICUBE2 gt Description If the area from OxFBOO to OxFCFF is used as a stack area the stacked data might become invalid Workaround There is no workaround Correction This issue has been corrected in V3 30 No 11 A break does not occur if an access breakpoint is specified for an odd address in byte units lt MINICUBE2 gt Description If an access breakpoint is specified for an odd address in byte units the break does not occur Workaround There is no workaround Correction This issue has been corrected in V3 30 No 12 Restrictions on software break points lt MINICUBE2 gt Description 1 Ifa software breakpoint is specified for RAM the first byte of the instruction becomes Oxff and the rest of the bytes become 0x00 2 If a software breakpoint is specified for the last address of a 64 KB boundary area such as Oxffff or Ox1ffff and execution stops at the specified point the PC value indicates the last address of the next 64 KB boundary area 0x1 ffff or Ox2ffff in the above case Workaround There is no workaround ZBG CD 10 0021 Attachment 6 13 Correction This issue has been corrected in V3 30 No 13 Restrictions on specifying access breakpoints lt Common gt Description 1 In the Watch window access breakpoints cannot be specified for variables other than global variables 2 Inthe Source window access breakpoints cannot
6. ariable window can be specified in the Font area in the Debugger Option dialog box which is opened by clicking the Option menu and then Debugger Option but if the font size is reduced the graphics before changing the font size remain in the window Example of Watch window Font size Large Font size Small Add Delete Up xig OAL Workaround Minimize the window and then restore the window size or close the window and then open it again Correction This issue has been corrected in V3 40 No 17 Restriction on moving using Address Move dialog box lt Common gt Description If the Address Move dialog box is opened by selecting the Move command on the shortcut menu in the Memory window an extra line might be displayed when the end address Oxfffff is input ZBG CD 10 0021 Attachment 8 13 Search KT DP Refresh DMM Close 4 7 Workaround Do not move to address Oxfffff Because this address is in the SFR area displaying this area in the Memory window is meaningless Correction This issue has been corrected in V3 40 No 18 Restriction on path name length lt Common gt Description Windows supports path names including file name consisting of up to 259 single byte characters but the ID78KOR QB cannot use 256 or more characters for path names If 256 or more characters are used for path names the operation becomes invalid For example if the path for a load mod
7. ated only to the display of the ID78KOR QB and program execution is not affected Problem 1 The data for an address other than the one specified for the pointer is displayed Example when the address OxOFFEAC is assigned to the pointer a When the pointer a is registered to the Watch window the data for OXOFFEAC is supposed to be displayed but the fifth least significant digit becomes 0 and the data for OxOOFEAC is displayed instead ZBG CD 10 0021 Attachment 12 13 yee 3 elles B Watch Slee Down Down Year Clas Clas number number name 20 name 20 Stature Stature wei ght we ght Incorrect display example Correct display example ID78KOR QB V3 50 or earlier Problem 2 The pointer cannot be expanded for display Example for the pointer a which points to a structure that has the members ec ui and ary When the structure pointer a is registered to the Watch window the members ec ui and ary cannot be expanded for display El Watch E E Ed Up Down Refresh str strfunc i str 3 B Watch str strftuncd str strfunc t unsigned ter a0 ui char alO arv i0 char al0 ary 0x0 char ary 0x1 char ary 0x2 char al ars 0x3 char ary 0x4 char ary 0x5 char ary 0x6 char ary 0x7 char ary 0x6 Incorrect display example Correct display example ID78KOR QB V3 50 or earlier Workaround There is no workaround Correction This issue has been corre
8. box and then add the source path manually Correction Under study No 2 Restriction on redraw lt Common gt Description When the Memory window is displayed in front of another window if the window behind the Memory window is clicked to the front and then the Memory window is clicked to the front again the line where the caret was placed and the portion which was overlapped by the other window appear blank in the Memory window Workaround Memory Search a4 Pe Refresh Addr 0 1 2 3 AA O FEFi 000 FEF20 FEF SOOO FEF 4O 00 FEF SOOO FEF 6 O00 FEF 000 FEF 700 FEF SOOO FEF AQTOO FEFBOIOO FEFCOWOO FEFO0 0 O0 O0 O0 O0 O0 O0 O0 O0 O0 O0 O0 O0 O0 O0 O0 O0 O0 O0 O0 O0 O1 O0 O0 O0 O0 O0 4 45 6 00 Re DMM 6 9 O00 OO OO O00 OO OO OO OO OO OO OO OO OO OO OO OO JA EF OO OO gd OO gd OO g Click the Refresh button or click on the blanked line to restore the original display Correction This issue has been corrected in V3 40 No 3 Symbols with a func var format cannot be converted to addresses lt Common gt Description This item is related to the specification so it is described in CHANGES IN USER S MANUAL in ID78KOR QB Operating Precautions ZBG CD 10 0021 Attachment 3 13 No 4 Searching fails in the Assemble window lt Common gt Description Searching might not be performed for the last 0
9. cted in V3 60 No 27 Restriction whereby a step execution result of the specific instruction is incorrect lt MINICUBE2 gt Description When an assembler instruction that has general purpose register offset as the access addressing operand is executed and this access addressing operand exceeds 10000H the result of step execution is incorrect This restriction is only on a step execution of MINICUBE2 ZBG CD 10 0021 Attachment 13 13 Note In case the instruction which includes below as the operand is executed HL byte DE byte SP byte word B word C word BC HL B HL C not including ES HL byte ES DE byte ES word B ES word C ES word BC ES HL B ES HL C Workaround There is no workaround Correction This issue will be corrected in the next version
10. eak occurs if the SP value is in the range of OxffcO2 to Oxffc04 if a debugger operation such as file downloading or software break setting which rewrites the internal ROM data is performed Workaround There is no workaround Correction This issue has been corrected in V3 50 ZBG CD 10 0021 Attachment 11 13 No 24 Restriction on reset during RRM or DMM lt MINICUBE2 gt Description If a reset is applied during RRM or DMM the error message A0109 Can not communicate with ICE Please terminate the debugger and check the power of ICE or the connection of cable then restart the debugger might be displayed Workaround Close the error message and wait for approximately 5 seconds Correction Under study No 25 Restriction whereby an external expansion area value was not displayed in the Memory window lt Common gt Description When using the external bus interface if the external expansion area is viewed in the Memory window all of the values become 0 This problem is related only to the display of the ID78KOR QB and program execution is not affected Workaround There is no workaround Correction This issue has been corrected in V3 60 No 26 Restriction whereby a pointer was displayed incorrectly in the Watch window lt Common gt Description The two incorrect display problems below occur if a pointer used as a function parameter or an automatic pointer is registered to the Watch window These problems are rel
11. ecified in the Memory Search dialog box and Assemble Search dialog box searching is not performed for any area beyond the area for which searching is prohibited Workaround There is no workaround Correction This issue has been corrected in V3 40 No 7 Invalid values are displayed in the Memory window lt Common gt Description Values in the general purpose register area and the results of access monitoring are not displayed correctly in the Memory window Workaround Check these values in the Register window ZBG CD 10 0021 Attachment 4 13 Correction This issue has been corrected in V3 30 No 8 Restriction on hardware break before execution lt IECUBE gt Description If multiple break before execution points are specified within a 4 byte boundary areaX the breaks do not occur as specified The following two cases are assumed Note A 4 byte boundary area means the addresses ranging from 4n to 4n 3 nis an integer Example 1 If a break before execution point is specified for addresses 1004 and 1006 in that order the break does not occur at address 1006 Assemble TAR B Example 2 If a break before execution point is specified for addresses 1004 and 1005 in that order and the breakpoint at address 1005 is removed the breakpoint at address 1005 remains valid Assemble Belta Search lt lt gt gt Watch Quick Refresh Glose B E Workaround T
12. empt is made to display the added SFR by using the Move command on the shortcut menu in the SFR window moving fails e The name of the SFR to be added is used for a general purpose register e The address to be added is the same as that of an SFR area different from the address of the general purpose register Workaround 1 When changing values in the Watch window input the value multiple times or change the values in the SFR window 2 There is no workaround 3 There is no workaround Correction This issue has been corrected in V3 40 After correction of 3 SFRs having the same names as general purpose registers can no longer ZBG CD 10 0021 Attachment 7 13 be added No 15 Restriction on rewriting PSW bits in DMM dialog box lt IEUCBE gt Description When changing register values in the DMM dialog box the error message A9004 Too large register size Is displayed if a PSW bit IE Z RBS1 AC RBSO ISP1 ISPO or CY is specified in the Register Name area but this error message is incorrect Workaround To change values of registers such as the PSW in the DMM dialog box specify the actual register not its bits To change individual bits use the Register window after the program has finished executing Correction This issue has been corrected in V3 40 Specifying the PSW bits is now available No 16 Restriction on changing font size lt Common gt Description The font size in the Watch window and Local V
13. has occurred Example When interrupt INTPO is defined as function int_p0O and INTP1 as function int_p1 ZBG CD 10 0021 Attachment 10 13 gt Code Coveraee E f fx Load Module almf Total Coverage it 652 Retresh Close Function Section Interrupt Coverage Correction This issue has been corrected in V3 40 The display after correction is as follows Status If the interrupt function is defined use is displayed otherwise nonuse is displayed e Coverage If an interrupt has occurred 100 0 is displayed otherwise 0 0 is displayed Code Coveraece Load Module almi Total Coverage i 47 0 Retresh Close Function Section Interrupt maskable MOMUSe OH 0 0 0 maskable Use 0x5 0 100 0 maskable Use Ona 0 0 0 No 22 Restriction on accessing the external bus lt Common gt Description When the external memory is written during a break access is always performed in 8 bit units regardless of the access size specified in the Memory Mapping area in the Configuration dialog box Workaround There is no workaround Correction Under study No 23 Restriction whereby a break occurs at a specific SP value lt MINICUBE2 gt Description 1 The program might hang up when a break occurs if the SP value is in the range of Oxffb02 to Oxffba6 while any of the Assemble window the Memory window or the SFR window is open or is opened 2 The program might hang up when a br
14. here is no workaround Clear all of the break before execution points within a 4 byte boundary area and specify just one break before execution point or use software breakpoints instead Correction This issue has been corrected in V3 30 No 9 Restrictions on coverage measurement lt IECUBE gt Description The following bugs a to c concerning coverage measurement occur a Coverage measurement CO coverage measures not only ROM fetch but also ROM read b When the read access status is displayed as a result of access monitoring in the Memory window the window displays not only the ROM read status but also the ROM fetch status c The general purpose register value displayed in the Memory window might become invalid ZBG CD 10 0021 Attachment 5 13 after accessing the RAM area to which the general purpose register is assigned In addition the Register window display might be invalid during program execution Workaround a There is no workaround b There is no workaround c There is no workaround Correction Issues a to c have been corrected in V3 30 After correction of a only ROM fetch is measured After correction of b only ROM read is displayed The modification affects the IECUBE QB 78KORKX3 and IECUBE self diagnostic tool IEQBUTL so be sure use them in the following combination QB 78KORKX3 ID78KOR QB IEQBUTL eee Code EFGH v320 ven J and later V3 30 and later V2 13 and later
15. o o o 13 Restrictions on specifying access breakpoints Common x x o oO 0 14 Restrictions on adding SFRs in Add VO Port dialog box Common x x o o o 15 _ Restriction on rewriting PSW bits in DMM dialogbox iecuBe x x o o 0 16 Common x x o o Oo 17 _ Restriction on moving using Address Move dialog box Common x x O Oo 0 Restriction on path name length Common X IX X X X x X X X x xX a Caution on Return Out in Source window Common a Restriction on BCD correction result register mo on Code Fs sper reenter rpm window nom 22 Restriction on Restriction on accessing the external bus sid the external bus Common PERERA Gla aan la value 24 Restriction on reset Restriction on reset during RRMorDMM sid RRM or DMM MINICUBE2 MINICUBE2 x x x fe ll Bal lel a was not displayed in the Memory window fala ell al Gal al a in the Watch window specific instruction is incorrect Common Items common to IECUBE and MINICUBE2 O Corrected or planned to be corrected x Not corrected 1 2 Restriction details No 1 Description ZBG CD 10 0021 Attachment 2 13 Source path cannot be added even if added using PM lt Common gt When a project is saved and then a new source path is added using PM the new path is not added to the ID78KOR QB Workaround On the Option menu select Debugger Options to open the Debugger Option dialog
16. ule is too long the module cannot be downloaded or if the path for a source file is too long the source file cannot be opened Workaround Specify path names using up to 255 characters including the file name Correction This issue has been corrected in V3 40 The number of characters that can be used for path names is now extended to 259 characters the maximum value supported by Windows No 19 Caution on Return Out in Source window lt Common gt Description Return Out is used to execute a program until execution returns to the address from which the function was called and uses a stack to predict the call source Due to this execution cannot return from locations where the association between the stack and the stack pointer is shifted location where the stack is currently being manipulated such as before execution of a function prologue or execution of an epilogue is in progress or where the program counter points to the middle not the beginning of a C source If Return Out is attempted at a location where Return Out cannot be performed the following error message is output ID BKOR QB ZBG CD 10 0021 Attachment 9 13 Workaround When the above error message is output step through the code and then execute Return Out After stepping through the code the difference between the stack address and stack pointer is resolved Correction The error message has been corrected in V3 40 The above workaround
17. x400 space of the range subject to searching in the Assemble window For example if the range 0x1000 to Ox1FFF is searched in the down direction and a character string that matches the search target exists in the range 0x1C00 to Ox1FFF the search might fail In the same manner if the range 0x2000 to Ox2FFF is searched in the up direction the search in the range 0x2000 to Ox23FF might fail Workaround Add a 0x400 space to the search target range To search a character string in the range 0x1000 to Ox1FFF in the down direction for example specify 0x1000 to 0x23FF Correction This issue has been corrected in V3 40 An additional 0x400 space 1 KB is now searched Consequently if target data exists in the search range the search definitely returns a hit As a result of this change however the search is performed on a wider range than specified so be sure to check if the hit data actually exists in the specified address range No 5 The Refresh button appears dimmed in the Watch window lt Common gt Description If an item at the bottom in the Watch window is deleted the Refresh button appears dimmed Workaround Close the Watch window and then open it again Correction This issue has been corrected in V3 30 No 6 Searching extending over a search prohibited area is impossible lt Common gt Description lf an area for which searching is prohibited non map area SFR area or I O protect area is included in the search target sp