1. SCREWS S TENSION SCREWS ree 5 G Laa Brake Tension Screw Detail Arm Adjustment Illustration PDI Communication Systems Inc 40 Greenwood Lane Springboro Ohio 45066 Phone 937 743 6010 Fax 937 743 5664 email pdi pdiarm com PDI Communication Systems Inc Phone 937 743 6010 PDI P10LCD C USER MANUAL 21 Document Number PD196 120R1 Model PDI P10LCD C Limited Warranty PDI Communication Systems Inc PDI warrants to the original purchaser only that the PDI P10LCD C will be free from defects in materials and workmanship under normal use for 2 years from the date of original purchase This warranty does not cover any other equipment that may have been included with PDI s shipment of this product After receipt of written notice of a defect or malfunction occurring during the warranty period PDI will repair or replace goods returned to its Springboro Ohio location at its discretion free of charge to the original purchaser the whole or any component part of any product manufactured by PDI and found by PDI to be defective As a condition to obtaining warranty service written notification must be received by PDI within at least ten 10 days after defect is first observed Repair of said product requires it to be shipped to the PDI factory in Springboro Ohio All shipments shall be F O B Springboro Ohio and all shipping and freight charges to PDI s factory shall be paid by the customer This warranty shall not
2. keypad for both channel and cursor control The 5 lower buttons are used to turn the TV ON or OFF change channels and raise or lower the sound volume If the speaker is currently programmed as OFF in the current service level see the section following on Power On Channel and Speaker the message Speaker Disabled will be displayed if either volume button is pressed while no earphone is connected In addition to the Channel Up and Down buttons the numbered direct entry keypad may be used to directly enter the channel desired for viewing If the channel entered using this keypad is not programmed in to the current Service Level see sections following on Service Levels and Channel Setup the symbol IXP will be displayed in red in place of the channel number and the channel will not change The 2 4 6 and 8 buttons on the direct entry Keypad are also used for cursor positioning on televisions used in computer control applications The cc button alternately activates and deactivates program closed captioning Note Not all programs offer closed captions Pressing the button may not result in the display of any captions The mute button will mute the TV audio The word MUTE will then appear on screen Pressing the button again or pressing the volume up or volume down buttons will enable the TV audio and remove the word MUTE from the screen BUTTON FUNCTI
3. Document Number PD196 120R1 Enable Disable Digital Channel 1 Press the SETUP button on the remote control A SETUP MODE screen will appear Using the CHA or CH Y buttons on the remote and select Channel Setup Press VOL Y or VOL A to enter the Channel Setup sub menu Select Enable Disable Digital Channels Note Only Digital channels found during Autoprogramming can be Enabled or Disabled for viewing If no Digital channels were found during autoprogramming the message No Channels Must Autoprogram will appear Using the CH A or CH Y buttons on the remote to select a Digital Channel or enter the channel number to advance directly to a channel Use the Volume A to Enable or the Volume Y button to Disable a Digital channel Press the SETUP button on the remote to exit Clear Service Level 1 Press the SETUP button on the remote control A SETUP MODE screen will appear Using the CH A or CH Y buttons on the remote and select Channel Setup Press VOL Y or VOL A to enter the Channel Setup sub menu Select Clear Service Level A menu will appear showing each service level and its current programmed or blank condition Using the CHA or CH Y buttons on the remote and select a Service Level VOL A will cause a confirmation message to appear VOL W will perform the cl
4. However improper use can result in potential electrical shock or fire hazards In order not to defeat the safe guards incorporated on this receiver observe the following basic rules for its installation use and servicing Your television is fully transistorized and does not contain any user serviceable components Removal of the cabinet cover may expose you to dangerous voltages Refer all servicing to qualified service persomnel 1 Read these instructions 11 Only use attachments accessories specified by the 2 Keep these instructions manufacturer 3 Heed all warnings 12 Use only with the cart stand 4 Follow all instructions tripod bracket or table 5 Do not use this apparatus near water IO Mamang ACUS pp or sold with the apparatus 6 6 Clean only with dry cloth When a cart is used use T Dono block any ventilation openings Install in caution when moving the accordance with the manufacturer s instructions cart apparatus combination to e 8 Do not install near any heat source such as radiators avoid injury from tip over heat registers stove or other apparatus including 13 Unplug this apparatus during lightning storms or when amplifiers that produce heat unused for long period of time 9 Do not defeat the safety purpose of the polarized or 14 Refer all servicing to qualified service personnel grounding type plug A polarized plug has two blades Servicing is required when the apparatus has been with one wider tha
5. apply to any PDI products subjected to improper use negligence or accident nor to tampering alterations or repairs by others without PDI s specific prior written authorization For information regarding authorized servicing and all other information pertaining to this warranty please contact PD COMMUNICATION SYSTEMS at 40 Greenwood Lane Springboro Ohio 45066 or phone 937 743 6010 This warranty gives specific legal rights and you may also have other rights which vary from state to state PDI s liability under this warranty is limited to repair or replacement of defective products and parts as provided above PDI shall not be liable for incidental or consequential damages The warranty contained herein is in lieu of all other expressed or implied warranties including any implied warranty of merchantability or fitness for any particular purpose PDI neither assumes nor authorizes any person to assume on its behalf any other obligation or liability Some states do not allow the exclusion of limitation of incidental or consequential damages or a disclaimer of warranties implied by law so the above limitation or exclusion may not apply The information and technical data in this manual is believed accurate but is not warranted and is subject to change without notice or obligation PDI and Better Solutions Are Within Reach are registered trademarks of PDI Communication Systems Inc Copyright 2004 2007 by PDI Commun
6. 0LCD C TV may be installed on other PDI 508C arms Please refer to Appendix A of this document for detailed instructions for this case PDI Communication Systems Inc 40 Greenwood Lane Springboro Ohio 45066 Phone 937 743 6010 Fax 937 743 5664 email pdi pdiarm com Phone 937 743 6010 8 PDI P10LCD C USER MANUAL Document Number PD196 120R1 INSTALLING THE PDI P10LCD C TO THE PDI 508C 7 SUSPENSION ARM 1 Remove and save the Ya Socket Head Cap Screw from the plastic H clip Remove the plastic H clip and discard 2 Remove the two nose cover retainer bolts Raise the metal nose cover and slide the television completely into the arm s clevis slot The Brake Pin 4 swivel retainer plate should rest inside the nose of the arm and A the plastic swivel cap beneath d see picture on previous page 4 A 3 Align the retainer plate s e mounting hole over the arm la E a mounting hole Thread the Ya Nose Cover Socket Head Cap Screw through ss the retainer plate and into the arm s nose Tighten 4 The coax cable in the nose of the arm should be joined with the coax cable from the television Wrench tighten the connection and cover by sliding the plastic boot sections into mating position IMPORTANT Finger only tightening of this cable connection will result in reliability problems weeks or months later Because the TV draws its power current through this connection eventually the finger tightened connection will loose
7. HA or CH Y buttons on the remote and select ASE Sas Features Press VOL W or VOL A to enter the Features p Features menu Select Power On ARC Language English Channel AY to select 3 The Power On ARC feature is available only for digital channels Volume A Y to change Use VOL Y or VOL A to select the type of Aspect Ratio the TV will use for its picture Normal Zoom Wide Cinema or Last 4 Press the SETUP button on the remote to exit Features Power on Channel and Speaker Volume Limiter 100 Caption Text Modes Disabled Time Zone Eastern Power On ARC Zoom Channel A V to select Volume A V to change PDI Communication Systems Inc 40 Greenwood Lane Springboro Ohio 45066 Phone 937 743 6010 Fax 937 743 5664 email pdi pdiarm com SETUP MODE Service Level PDI P10LCD C USER MANUAL 17 Document Number PD196 120R1 Language 4 Press the SETUP button on the remote control A SETUP MODE screen will appear Picture 2 Using the CHA or CH Y buttons on the remote and select Channel Setup Language Features Language English 3 Press VOLW or VOL A to toggle between English Spanish or Naas French languages All on screen User and Setup menus and the olume A V to change f text displayed during normal TV operation will change to the selected language NOTE adjustment of the Language setting does n
8. Installation P RS O NA 0 Operating MOspital Grade LCD Instructions Digital Television Receiver MODEL PDI P10LCD C Communication Systems Inc 40 Greenwood Lane Springboro Ohio 45066 PH 937 743 6010 FX 937 743 5664 i Better Solutions Are Within Reach http www pdiarm com DOCUMENT NUMBER PD196 120R1 2 PDI P10LCD C USER MANUAL Document Number PD196 120R1 Graphical Symbols This lightning flash with arrowhead symbol within an equilateral is intended to alert the user of the presence of uninsulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons The exclamation point within an equilateral triangle is intended to alert the user of the presence of important operating and maintenance servicing instructions in the literature accompanying the appliance CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION TO REDUCE THE RISK OF ELECTRICAL SHOCK DO NOT REMOVE COVER NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL Important Safety Instructions PLEASE READ AND KEEP THESE INSTRUCTIONS OBSERVE ALL WARNINGS AND FOLLOW ALL INSTRUCTIONS CONTAINED IN THESE SAFETY INSTRUCTIONS AND THOSE ON YOUR TELEVISION RETAIN THESE INSTRUCTIONS FOR FUTURE USE Electrical energy can perform many useful functions This unit has been engineered and manufactured to assure your personal safety
9. M cito dado ci 15 Caption Text MOUSE M a DG ag a AD Dak aa a WANG Ba las 19 TG ZONE wana La reais ash a ae tl a a a AE aa A Dk 16 Power OR ARG ia babana o da AE Ka a Sd b a aa 16 Language sa aa a b ag aa Na AN E ia sde 17 PICTURES kaa a a aa a no a a a DE Aa ot co 17 FAQ Frequently Asked Questions 18 APPENDIX A Installation on Other PDI 508C Arms 19 Model PDI P10LCD C Limited Warranty 21 PDI Communication Systems Inc 40 Greenwood Lane Springboro Ohio 45066 Phone 937 743 6010 Fax 937 743 5664 email pdi pdiarm com PDI P10LCD C USER MANUAL Document Number PD196 120R1 About the PERSONA 10 This television is specifically designed for entertainment purposes and for use ina hospital a nursing home a medical care center or a similar health care center in which installation is limited to a non hazardous area in accordance with the National Electrical Code ANSI NFPA 70 This user s guide has been designed for both the TV installer and TV Rental Representatives It identifies the features of the PERSONA 10 and describes how to program the TV using an infrared IR remote control Programming is the process of selecting from among the many features of the PERSONA 10 television It is also the process of adding and removing channels from the three service levels this TV provides Please read through this guide carefully with a PERSONA 10 TV in front of you as you begin the process of le
10. ON SUMMARY POWER Turns the TV ON or OFF VOLUME Increase or decrease the TV volume CHANNEL Changes the viewed channel up or down ENTER Used for entering channel numbers or viewing current channel information MUTE Mutes TV audio CC Activates or deactivates closed captions FEATURE Allows selection of Aspect Ratio for digital channels only NUMBERS Direct channel entry PDI Communication Systems Inc 40 Greenwood Lane Springboro Ohio 45066 Phone 937 743 6010 Fax 937 743 5664 email pdi pdiarm com 10 PD108 112 Headset PDI Communication Systems Inc Phone 937 743 6010 PDI P10LCD C USER MANUAL Document Number PD196 120R1 Earphone Operation Inserting an earphone in the earphone jack hole located on the right side of the cabinet will allow silent operation of the TV The speaker will be shut OFF and all program audio will be available through the earphone Remove the earphone to enable the internal TV speaker The TV only offers mono sound Use of a stereo earphone will result in sound from only one earphone speaker Contact PDI for either earphone or mono style headsets Remote Control The PERSONA 10 requires a remote control part number PD108 412 to program the set You will NOT find a remote control packed with the television The remote control is an available option and would be shipped separate from the television The remote control has a limited range to prevent dual programming of an adjace
11. arning how to program these televisions Also keep the guide handy so you can refer to it for future programming changes The information in this guide describes each of the main SETUP MENU items Service Levels Channel Setup Programming Features Doo O Picture Adjustment PDI Communication Systems Inc 40 Greenwood Lane Springboro Ohio 45066 Phone 937 743 6010 Fax 937 743 5664 email pdi pdiarm com PDI P10LCD C USER MANUAL 7 Document Number PD196 120R1 Installing TV on Suspension Arm The PERSONA 10 is designed to mount on a wall mounted suspension arm capable of supporting a television weighing 7 pounds The single coaxial cable on top of the unit is used to supply both low voltage AC or DC power range 18 to 32 volts and the RF signal to the television Safety Brake Pin Hole 3 4 Socket Head Cap Screw Swivel Cap ec 7099 2 gt 0 AAA DANGER ARM RECOIL HAZARD The safety brake pin must remain in the SAFETY BRAKE PIN HOLE whenever the television set is removed from the arm or when the arm is removed from the wall bracket to prevent the arm from springing open CAUTION DO NOT remove the WHITE PLASTIC CAP from the swivel assembly This swivel assembly is factory preassembled and adjusted There is no need to remove the cap IMPORTANT These instructions detail installing the PDI P10LCD C TV onto the PDI 508C 7 suspension arm This arm is configured specifically for this television The PDI P1
12. ce level Use the CH A or CH Y to set the From and To service levels VOL A will cause a confirmation message to appear VOL Y will perform the copy Press SETUP to Cancel Press the SETUP button on the remote to exit Power on Channel and Speaker 1 4 Press the SETUP button on the remote control A SETUP MODE screen will appear Using the CH A or CH Y buttons on the remote and select Features Press VOL Y or VOL A to enter the Features menu Select Power on Channel and Speaker sub menu A listing of service levels are shown with current settings shown Channel when the TV is powered ON you may have the TV start on a pre selected channel This feature is useful for selecting a hospital welcome or message channel Directly enter a channel number and press ENTER to select Otherwise press the LAST button The TV will return to the last channel viewed when Last is selected Speaker The internal television speaker may be turned OFF silenced if headphone only service is required Press the SETUP button on the remote to exit Springboro Ohio 45066 email pdi pdiarm com 40 Greenwood Lane Fax 937 743 5664 PDI P10LCD C USER MANUAL 1 5 Document Number PD196 120R1 Volume Limiter 1 Press the SETUP button on the remote control A SETUP MODE screen will appear SETUP MODE Se
13. d for almost all installations NOTE Text 1 and Text 2 modes are normally not Power on Channel and Speaker used in hospitals Volume Limiter 100 Caption Text Modes Disabled ta aa IN 4 Press the SETUP button on the remote to exit Features Channel A V to select Volume A V to change PDI Communication Systems Inc 40 Greenwood Lane Springboro Ohio 45066 Phone 937 743 6010 Fax 937 743 5664 email pdi pdiarm com 1 6 PDI P10LCD C USER MANUAL Document Number PD196 120R1 Time Zone 1 Press the SETUP button on the remote control A SETUP SETUP MODE MODE screen will appear Service Level Free 2 Using the CHA or CH Y buttons on the remote and select ia Sip Features Press VOL Y or VOL 4 to enter the Features Features menu Select Time Zones Language English Channel A V to select 3 Use the VOLV or VOL A keys to change to the Local Time Volume A V to change Zone used at your hospital s location Time Zone is only used when viewing Digital channels 4 Press the SETUP button on the remote to exit Features Power on Channel and Speaker Volume Limiter 100 Caption Text Modes Disabled Time Zone Eastern Power On ARC Zoom Channel A V to select Volume A V to change Power On ARC 1 Press the SETUP button on the remote control A SETUP SETUP MODE MODE screen will appear Service Level Free 2 Using the C
14. ear or press SETUP to Cancel Springboro Ohio 45066 email pdi pdiarm com 40 Greenwood Lane Fax 937 743 5664 14 Channel Setup Signal CATV Autoprogram Clear Service Level Add Delete Analog Channels Copy Service Level Enable Disable Digital Channel Channel A V to select Volume A V to change Copy Service Level From Free To Basic Channel A to adjust From Channel Y to adjust To Volume A Perform Copy SETUP to Cancel SETUP MODE Service Level Premium Picture Channel Setup Features Language English Channel A V to select Volume A V to change Features Power on Channel and Speaker Volume Limiter 100 Caption Text Modes Disabled Time Zone Eastern Power On ARC Zoom Channel A V to select Volume A V to change Power on Channel and Speaker Channel Speaker Free 8 On Basic Last On Premium Last On Channel A V Select Service Level 0 9 Channel ENTER LAST Volume A V Adjust Speaker PDI Communication Systems Inc Phone 937 743 6010 PDI P10LCD C USER MANUAL Document Number PD196 120R1 Copy Service Level 1 Press the SETUP button on the remote control A SETUP MODE screen will appear Using the CH A or CH Y buttons on the remote and select Channel Setup Press VOL Y or VOL A to enter the Channel Setup sub menu Select Copy Service Level A menu will appear showing a From service level and To servi
15. emium Blank Channel A V to select Volume A V to change You may also tune directly to a channel during editing by entering its number on the remote s keypad PDI Communication Systems Inc Phone 937 743 6010 PDI P10LCD C USER MANUAL Document Number PD196 120R1 Channel Setup il AUTOPROGRAMMING Press the SETUP button on the remote control A SETUP MODE screen will appear Using the CH A or CH Y buttons on the remote and select Channel Setup Press VOL Y or VOL A to enter the Channel Setup sub menu Select the correct Signal type either CATV Air CATV IRC or CATV HRC CATV is most commonly use in Hospitals Select Autoprogram In the Autoprogram menu select the Mode type Analog Only Digital Only Analog and Digital Now select the Service Level you wish to program Free Basic or Premium Note A Programmed service level can be reprogrammed if desired A Confirm Autoprogram Start menu will now appear To continue press Chl A to begin autoprogramming Press Chl Y to exit Add Delete Analog Channels 1 Press the SETUP button on the remote control A SETUP MODE screen will appear Using the CH A or CH Y buttons on the remote and select Channel Setup Press VOL Y or VOL A to enter the Channel Setup sub menu Select Add Delete Analog Channels A Menu showi
16. ervice levels Free Basic and Premium Program the maternity or educational channels into the Premium service level Televisions placed into those locations that require maternity or educational services would simply have their service level set to Premium Our hospital has a Welcome Channel How do program the TV to start on the Welcome Channel every time it is turned ON The PERSONA 10 offers a Power On Channel setting for each service level Use the Power On Channel Speaker menu and set the Power On Channel to the hospital Welcome channel number Pressing the Feature button does not always changes the picture Aspect Ratio Sometime it works sometimes it doesn t work The PERSONA 10 offers both analog and digital channel capability Only those channels that are digital respond to the Feature button and change picture aspect ratios Analog channels do offer different aspect ratios and will not change when the Feature button is pressed The TV appears dead and it doesn t work The PERSONA 10 is powered through a connecting coaxial cable from an external power supply Contact the hospital maintenance department and have them verify correct powering of the TV 40 Greenwood Lane Springboro Ohio 45066 Fax 937 743 5664 email pdi pdiarm com PDI P10LCD C USER MANUAL 1 9 Document Number PD196 120R1 APPENDIX A Installation on Other PDI 508C Arms The suspension arm must be adjus
17. ewing standard message appears on a black screen O FREE lets patients watch hospital education and information channels without renting the television The channels containing programming for no charge are typically programmed into this level of service This is the factory default setting for service level The Free level is indicated in the SETUP MODE menu screen when Service Level Free BASIC service typically allows additional channels beyond those offered in the FREE level The Basic level is indicated in the SETUP MODE menu screen when Service Level Basic PREMIUM is the highest service level with typically the most channels available for viewing The premium level is indicated in the SETUP MODE menu screen when Service Level Premium 40 Greenwood Lane Fax 937 743 5664 Springboro Ohio 45066 email pdi pdiarm com 12 Channel Setup Signal CATV Autoprogram Clear Service Level Add Delete Analog Channels Copy Service Level Enable Disable Digital Channel Channel A V to select Volume A V to change Autoprogram Mode Analog Only Free Programmed Basic Blank Premium Blank Channel A V to select Volume A V to change Channel Setup Signal CATV Autoprogram Clear Service Level Add Delete Analog Channels Copy Service Level Enable Disable Digital Channel Channel A V to select Volume A V to change Add Delete Analog Channels Free Programmed Basic Programmed Pr
18. ication Systems Inc All rights reserved 40 Greenwood Lane Springboro Ohio 45066 Fax 937 743 5664 email pdi pdiarm com
19. n develop resistance and prompt a service call Wrench tighten all F fitting connections 5 Remove the safety brake pin from the parking brake hole reattach the acorn nut to the pin and store the assembly inside the nose of the arm by attaching it to the coax cable using the attached plastic clip 6 Close the metal nose cover onto the nose Reinstall the two nose cover retainer bolts 7 Attach three sets of plastic arm covers start with long nose cover section Assemble supplied spring pins into one of the arm cover halves Pins should be installed into one cover Pin side only Y Position the Arm Cover halves 4 around the arm s nose section Align exposed pins with the open holes in the second cover half Squeeze the two halves together When the halves are properly installed there should only be a thin seam visible where the halves meet Repeat steps a b c for the elbow covers and base covers 8 Connect the coax cable at the base of the arm to the wall bracket F fitting Wrench tighten Cycle the arm once or twice to check for free movement PDI Communication Systems Inc 40 Greenwood Lane Springboro Ohio 45066 Fax 937 743 5664 email pdi pdiarm com PDI P10LCD C USER MANUAL 9 Document Number PD196 120R1 Control Panel BN 2 KEYPAD The easy to clean membrane control panel located on the lower front of the TV contains 9 large easy to read buttons and a numbered direct entry
20. n a Health Care Facility This TV will operate on either DC or AC voltage range 18 to 32 volts THIS INSTALLATION SHOULD BE MADE BY A QUALIFIED SERVICE PERSON AND SHOULD CONFORM TO ALL LOCAL CODES READ AND FOLLOW THE SAFETY INSTRUCTIONS BEFORE ATTEMPTING THIS INSTALLATION NOTE TO CATV INSTALLER This reminder is provided to call the CATV system installer s attention to Article 820 40 of the NEC that provides guidelines for proper grounding and in particular specifies that the cable ground shall be connected to the grounding system of the building as close to the point of cable entry as practical COAX CABLE SPECIFICATION When using a central power supply cable selection is crucial Due to long coax cable runs encountered in hospital installations coax cable employing a solid copper center conductor and copper shield is required Cable run lengths MUST NOT exceed 150 feet Required coaxial cable numbers include Alpha 9804C non plenum Belden 9248 non Plenum West Penn 806 non Plenum or West Penn 25806 Plenum which have been tested with coax powered televisions CLEANING Clean the exterior of this television by removing dust with a lint free cloth For further cleaning use a soft cloth or paper towel dampened with water CAUTION To avoid damage to the surface of the television do not use abrasive or chemical cleaning agents DISINFECTING Do not immerse this TV rather clean with a soft damp cloth To avoid damage to
21. n the other A grounding type plug damaged in any way such as power supply cord or has two blades and a third grounding prong The plug is damaged liquid has been spilled or objects wide blade or the third prong are provided for your have fallen into the apparatus the apparatus has safety If the provided plug does not fit into your been exposed to rain or moisture does not operate outlet consult an electrician for replacement of the normally or has been dropped obsolete outlet 10 Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus PDI Communication Systems Inc 40 Greenwood Lane Springboro Ohio 45066 Phone 937 743 6010 Fax 937 743 5664 email pdi pdiarm com PDI P10LCD C USER MANUAL 3 Document Number PD196 120R1 WARNING To reduce the risk of fire or electric shock do not expose this apparatus to rain or moisture WARNING OXYGEN ENVIRONMENT Do not use in any oxygen tent or oxygen chamber Such use may cause a fire hazard Apparatus shall not be exposed to dripping or splashing and no objects filled with liquids such as vases Shall be placed on the apparatus Copyright Disclaimer and Trademarks COPYRIGHT PDI Communication Systems Inc claims proprietary right to the material disclosed in this user manual This manual is issued for user information only and may not be used to manufacture anything shown herein Co
22. ng the three programmable service levels will appear with its current status Select the service level to add or delete channels in The TV will now display an Analog channel in the service level selected An on screen menu will show the channel number at the top right and the current service level A green channel number indicates an active channel that is viewable in that service level A red channel number indicates that channel is not programmed into the current service level Use the Volume A V to Add or Delete an Analog channel Once the service level is programmed press SETUP to exit the menu Springboro Ohio 45066 email pdi pdiarm com 40 Greenwood Lane Fax 937 743 5664 Channel Setup Signal CATV Autoprogram Clear Service Level Add Delete Analog Channels Copy Service Level Enable Disable Digital Channel Channel A V to select Volume A V to change Enable Disable Digital Channel Channel A V to select channel 0 9 Enter Adjust Channel Volume A to Enable Volume Y to Disable SETUP to Exit Channel Setup Signal CATV Autoprogram Clear Service Level Add Delete Analog Channels Copy Service Level Enable Disable Digital Channel Channel A V to select Volume A V to change Clear Service Level Free Programmed Basic Programmed Premium Blank Channel A V to select Volume A to clear SETUP to Cancel PDI Communication Systems Inc Phone 937 743 6010 PDI P10LCD C USER MANUAL 1 3
23. ng the equipment off and on the user is encouraged to try to correct the interference by one of more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help Underwriters Laboratories The model PDI P10LCD C Hospital Grade LCD TV is a specialized LCD U television and should be installed to National Electrical Code specifications cl Y L Jus This device is safety tested and listed by the Underwriters Laboratories as a LISTED product suitable for use in health care facilities in both the United States and Canada PDI Communication Systems Inc 40 Greenwood Lane Springboro Ohio 45066 Phone 937 743 6010 Fax 937 743 5664 email pdi pdiarm com PDI P10LCD C USER MANUAL Document Number PD196 120R1 Installation Precautions le 2 3 4 5 USE RECOMMENDED COAX USE OF ANY OTHER CABLE NUMBER IS NOT RECOMMENDED 6 8 9 PDI Communication Systems Inc Phone 937 743 6010 Any changes or modifications in construction of this television which are not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment Use only a power source from a CSA Certified UL Approved Class 2 Power Supply suitable for use i
24. nt room TV Stand within 3 feet from the front of the TV to use the remote control FREE BASIC PRREHIUH DISPELED SETUP Sa PAID LOCKED UNLOCGRED Por POl0S 412 Springboro Ohio 45066 email pdi pdiarm com 40 Greenwood Lane Fax 937 743 5664 To use this television Please contact TV representative SETUP MODE Service Level Free Picture Channel Setup Features Language English Channel A V to select Volume A V to change SETUP MODE Service Level Basic Picture Channel Setup Features Language English Channel A V to select Volume A V to change SETUP MODE Service Level Premium Picture Channel Setup Features Language English Channel A V to select Volume A V to change PDI Communication Systems Inc Phone 937 743 6010 PDI P10LCD C USER MANUAL 11 Document Number PD196 120R1 Service Levels Tiers The PERSONA 10 contains four separate service levels tiers allowing the hospital to offer either basic or enhanced viewing The current service level can be quickly determined by accessing the SETUP MODE menu using the handheld programming remote control The service level can be changed to any of the 4 levels at any time using the dedicated buttons on the attendant remote or entering the setup menu and changing the Service Level menu items DISABLED is like a mechanical keylock when in Disabled service level the TV can be turned OFF and ON but cannot be used for vi
25. ot change the TV s program language 4 Press the SETUP button on the remote to exit Picture 1 Press the SETUP button on the remote control A SETUP NEG NE MODE screen will appear Service Level ee 2 Using the CHA or CH Y buttons on the remote and select Channel Setup Picture Press VOL Y or VOL A to enter the Picture sub Features menu Language English Channel A V to select 3 Select the picture parameter using CHA or CH Y buttons on adi the remote Press VOL Y or VOL A to adjust the parameter An actual picture will appear with a bar graph shown at the bottom of the picture screen Using the VOL Y or VOL A buttons to PICTURE adjust the parameter for best picture After adjustment press the Brightness SETUP button to return and select another parameter Contrast So 4 Press the SETUP button again on the remote to exit Channel A V to select Volume A V to change Springboro Ohio 45066 email pdi pdiarm com 40 Greenwood Lane Fax 937 743 5664 PDI Communication Systems Inc Phone 937 743 6010 18 PDI P10LCD C USER MANUAL Document Number PD196 120R1 FAQ Frequently Asked Questions Q PDI Communication Systems Inc Phone 937 743 6010 Our hospital offers maternity and other educational services to select areas of the hospital How do program for these channels only The PERSONA 10 offers three distinct s
26. pyright 2000 2007 by PDI Communication Systems Inc All rights reserved Manufactured under license from Dolby Laboratories Dolby and the double D symbol are trademarks of Dolby Laboratories DISCLAIMER The author and publisher have used their best efforts in preparing this manual PDI Communication Systems Inc make no representation or warranties with respect to the accuracy or completeness of the contents of this manual and specifically disclaim any implied warranties or merchantability or fitness for any particular purpose and shall in no event be liable for any loss of profit or any other damages The information contained herein is believed accurate but is not warranted and is subject to change without notice or obligation TRADEMARKS All brand names and product names used in this manual are trademarks registered trademarks or trade names of their respective holder PDI and Better Solutions Are Within Reach are registered trademarks of PDI Communication Systems Inc Springboro Ohio Regulatory Information FCC This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a residential or commercial installation If this equipment does cause harmful interference to radio or television reception which can be determined by turni
27. rvice Level Premium Pt 2 Using the CHA or CH Y buttons on the remote and select a Setup Features Press VOL W or VOL 4 to enter the Features eatures 66 me angie English menu Select Volume Limiter SHANG ya T rede 3 Use the VOL W or VOL A keys to set the maximum level of Volume A V to change volume available Once set the volume for the speaker for all service levels will be limited to the value specified This setting does not affect the maximum volume achievable when an earphone is connected Features Power on Channel and Speaker i Volume Limiter 70 4 Press the SETUP button on the remote to exit Caption Text Modes Disabled Time Zone Eastern Power On ARC Zoom Channel A V to select Caption Text Modes SETUP MODE 1 Press the SETUP button on the remote control A SETUP EN MODE screen will appear ervice Level Free RUE ae 2 Using the CHA or CH Y buttons on the remote and select Ta Ne Features Press VOL Y or VOL A to enter the Features Language English menu Select Caption Text Modes Channel A V to select Volume A W to change 3 Use the VOLW or VOL A keys to enable or disable Caption Text Modes When enabled two additional Text 1 Text 2 options are available when the user presses the closed caption CC button Caption Text Modes are disable
28. ted to the proper weight of the television in order to operate correctly PDI arm model PDI 508C 7 is factory adjusted for the proper weight If this television is installed on a previously existing suspension arm adjustment of the internal springs may be required The PDI P10LCD C television must be installed on the arm before making this adjustment PROCEDURE EXISTING TELEVISION REMOVAL LCD TELEVISION INSTALLATION 1 Remove the safety brake pin from the nose of the existing arm and install into the Brake parking brake hole at the base of the arm Retainer 2 Remove the existing television from the arm Plate The swivel retainer plate and nut will not be needed for the new television so T 3 Remove and discard the 4 20 x Socket z a 4 Head Cap screw swivel retainer bolt from the bottom of the nose Socket Head Cap Screw 4 Install the new LCD television onto the nose by following the steps in the Installing TV on Suspension Arm section of this document ARM ADJUSTMENT Please refer to the Arm Adjustment Illustration on the following page 1 Remove the elbow access cover 2 Loosen each of four Brake Tension Screws Y turn only Brake Tension screws are located on both sides of the base and nose See Brake Tension Screw Detail illustration Locate each internal spring s 7 16 Hex head adjustment bolt While maintaining a firm grip on the bottom of the television carefull
29. the surface of the television test a small portion of the TV s cabinet with any new disinfectant to verify that the disinfectant will not discolor or soften the enclosure WARNING To avoid the hazards of fire or electrical shock DO NOT expose this television to rain or moisture WARNING OXYGEN ENVIRONMENT Do not use in any oxygen tent or oxygen chamber Such use may cause a fire hazard 40 Greenwood Lane Springboro Ohio 45066 Fax 937 743 5664 email pdi pdiarm com PDI P10LCD C USER MANUAL 5 Document Number PD196 120R1 Contents Graphical SyYmMDOIS ais Sitesi ike anual ike Ui aa a a A eee ns es eee aa an Ka nine 2 Important Safety InstuciOAS insistent nee 2 Copyright Disclaimer and Trademarks 3 Regulatorio Malos ba 3 Installation PrecatioOnS cia aida 4 COMES lao NOR 5 ADOULING PERSONA TO osas 6 Installing TV on Suspension AM sit 7 Control PAM lees babasan a ak pk a ag Aa aa na Jaa ips 9 Earphone OPE O Mirror cani oa e ka Waa Ka NO BA BN a nean aga a e Ban aa a ets 10 Remote COMO lk aaa kaka baa NN Unes ak aa anaa a a ea aa aaa NENG 10 Service Levels Tiers aaa aee anana aaa aane aana 11 CHANNEL SENIN aana o A A 12 Add Delete Analog Channels 12 Enable Disable Digital Channel ss 13 Clear Service Level Re 13 Copy Service Levels aaa ian ian Gada a SE jaba Na Daka Wa Gb a aaa ka Na aa aa kara aba 14 Power on Channel and Speaker ss 14 Volume IM
30. y remove the safety brake pin from the parking brake hole at the base of the arm 5 Adjust the Front Internal spring bolt WARNING DO NOT loosen more than 10 complete turns Any more turns beyond 10 will result in disconnecting the spring and cause the arm to fall rendering the arm useless and possibly causing personal injury 6 Adjust the Rear Internal spring bolt WARNING DO NOT loosen more than 10 complete turns Any more turns beyond 10 will result in disconnecting the spring and cause the arm to fall rendering the arm useless and possibly causing personal injury After reaching the desired adjustment re tighten all four Brake Tension Screws Replace the elbow cover NOTE The internal springs are adjusted by loosening counter clockwise to decrease the arm s lifting force or tightened clockwise to increase the arm s lifting force As adjustments are made move the TV to different positions The adjustment is correct when the TV can be positioned without any creepage either up or down If you need assistance during this procedure contact PDI s Service Department at 937 743 6010 PDI Communication Systems Inc 40 Greenwood Lane Springboro Ohio 45066 Phone 937 743 6010 Fax 937 743 5664 email pdi pdiarm com 20 PDI P10LCD C USER MANUAL Document Number PD196 120R1 Appendix A Continued Elbow Cover FRONT ES by SPRING oe REAR FRONT SPRINGS SPRINGS nl ATAA TENSION SPRING BRAKE
Download Pdf Manuals
Related Search
Related Contents
Communiqué de presse - FFCT Habib® 2X Laparoscopic or Habib® 4X User Manual - Intellihome FAIT- CRAYON DE RETOUCHE Manual de instrucciones Medidor de Cadencia FICHE TECHNIQUE PROCOL MS-12 5. Solscreen compact R 1105 GUIDE D`ACCOMPAGNEMENT A LA GPEC JVC RC-EZ38S User's Manual 再処理工場 使用済燃料受入れ・貯蔵建屋における 第1非常用ディーゼル Copyright © All rights reserved.
Failed to retrieve file