12 Cue Wireless Firing System
Contents
1. MS12Q 12 Cue Wireless Firing System 12 cues Dual Power Modes FCC Certified USER INSTRUCTIONS If a FIRE LED labeled left stays lit when the unit is powered on no matter which position the rocker switch is in and at the same time the corresponding TEST LED is l always off the channel has been Learn shorted and permanently dam TERAN RINE aged iF THIS OCCURS DO NOT Ou AMM USE THIS CHANNEL as the channel will fire an igniter without any operation by the user Discontinue use of the shorted out channel until the system can be repaired or replaced Additionally if the DIGITAL DISPLAY labeled above turns off and at the same time the FIRE LEDs and TEST LEDs are turned on while the rocker switch is in the TEST or ARM position then immediately turn off the firing system and remove or disconnect the batteries IF THIS OCCURS DO NOT USE THE SYSTEM as it will fire igniters without any operation by the user Discontinue use of the system until it can be repaired or replaced DISCLAIMER The manufacturers distributors and sellers of this device accept no responsibility whatsoever for any dam age injury or loss financial or otherwise resulting directly or indirectly from the use misuse function or malfunction of this device By purchasing and using this device you understand and accept this disclaimer Description The MS12Q Wireless Firing System is FCC Certified and represents the newest techno
2. module receiver is connected to a MASTER unit through the RS485 ports on the side of the receiver and the MASTER unit is turned on the receiver will select Wired Control mode automatically and the wireless control mode will be disabled Additionally the Wired Control Mode LED 12 will be on Receiver ID Each MS12Q receiver is assigned a unique ID for use in wired control mode To look up the unique ID assigned to the receiver follow the procedure outlined below e Onthe field module receiver turn the safety key switch 6 to the ON position Then shift the three position switch 7 to the TEST position e The last three digits of the receiver ID will be displayed on the digital readout 11 e Next press and hold the LEARN button 9 for approximately three 3 seconds then re lease the button The next three digits of the receiver ID will be displayed on the digital readout 11 e Next press and release the LEARN button again and the next three digits of the receiver ID will be displayed on the digital readout e Next press and release the LEARN button again and the next three digits of the receiver ID will be displayed on the digital readout e Next press and release the LEARN button again and the final digits of the receiver ID will be displayed on the digital readout Example If the receiver ID is 00 030 06c 05c 769 Digital readout goes back when no press within 3 seconds 00 F030 M7 L067 Lose fT hit hee p
3. dule receiver will take commands from your remote Clear any previously stored remote transmitter codes On the field module receiver turn the safety key switch 6 to the ON position Then make sure the three position switch 7 is in the LEARN position Finally press and hold the LEARN button 9 for a minimum of six 6 seconds until the ARM LEARN LED 8 turns on and then blinks three 3 times Once the ARM LEARN LED blinks three 3 times then all previously stored remote transmitter codes have been successfully cleared LEARN Procedure for Transmitter On the field module receiver turn the safety key switch 6 to the ON position Then shift the three position switch 7 to the LEARN position Press the LEARN button 9 for approximately three 3 seconds until the ARM LEARN LED 8 turns on Then release the button Within three 3 seconds press any button on the Transmitter make sure the remote power switch is turned on The ARM LEARN LED 8 will blink two times confirming successful learning The receiver LEARN process is now completed for the remote transmitter Confirm that the LEARNING procedure was successful On the field module receiver turn the safety key switch 6 to the ON position Then shift the three position switch 7 to the ARM position On the Transmitter press any button labeled 1 through 12 make sure the remote power switch is turned on On the field modul
4. e receiver the corresponding Cue Fire LED 5 should be turned on and then turn off after 0 5 second NOTE The field module receiver can store the code of one transmitter at a time If you have another transmitter code already stored in the receiver then those codes will have to be cleared prior to learning any new transmitter codes WARNING Only when no fireworks are connected to the firing system may the LEARN or CLEAR procedure be performed Never perform these procedures when fireworks are connected Accidental ignition may occur How to Use TEST Igniter Circuit With an e match or igniter connected to a cue on the field module receiver turn the key switch to the ON position and shift the three position switch to the TEST position If the Cue TEST LED for the cue is ON and the Cue FIRE LED is OFF then your circuit has good continuity otherwise your circuit is broken and the igniter will not fire Check your igniter connection Replace defective igniter if necessary Firing Procedure After your exterior circuits igniters have tested as being good follow the following procedure for firing the cues FIRE Procedure On demand cue firing There are 12 cues on the field module receiver labeled 1 through 12 On the remote transmitter there are 12 buttons labeled 1 through 12 The numbers on the remote trans mitter correspond directly with the cue numbers on the field module receiver for the firing procedure On t
5. e once This ability allows for totally flexible setup arrays Dual Power Modes The field module receiver operates on ten 6 AA batteries OR an external battery connected to the external battery jack External battery recommendation Sealed Lead Acid SLA re chargeable 12 VDC 10 aH Using a remote firing system like our MS12Q is much safer than lighting by hand The MS12Q is a versatile and economical answer to a vast matrix of consumer wireless firing demands Transmitter Remote Model TCF100 12LN FCC Certified FCC ID YMUT10012LN Power 23A 12V battery not included Frequency RF Radio 433 92 MHz Buttons 12 buttons total Buttons marked 1 2 3 4 5 6 7 8 9 10 11 12 This transmitter is used for instant on demand firing The cues assigned to each button will fire immediately when the button is pressed Transmitter has an ON OFF switch for added safety Unit will not operate when in the OFF position there by eliminating the risk of an inadvertent button press Receiver Field Module 6 rn Sw Power j Exte na Model MS12Q FCC certified Field Modules 1 containing 12 cues total Power 6 AA Batteries or optional external SLA battery 12 V 10aH Firing Current gt 750 mA Max 10A Test Current lt 40mA Size 154 mm x 108 mm x 38 mm Firing Capacity 3 Falcon Igniters per cue Learn External Ar W Bower LAW Arm O Test Legend Antenna ext
6. endable Back of Unit Igniter Terminal black total of 12 Igniter Terminal red total of 12 Cue TEST LED total of 12 LEDs Cue FIRE LED total of 12 LEDs 11 Digital readout Key switch main power switch 12 Wired control LED future use 3 position switch Arm Learn Test 13 Battery enclosure Arm LED Learn LED 14 Battery cover Learn button O ON DUH ARUNA 10 External battery jack Components AA Battery 6 pcs Transmitter not included SLA External Battery MS12Q Field Module Receiver TCF100 12LN Alligator Clip Wire optional not included Note Alligator Clip Wire is for external battery connection Red clip is for anode black clip is for cathode Before Use Install batteries Before using your new firing system you will need to install one 23A 12V battery in the remote transmitter and 6 AA batteries in the field module receiver You will need a total of 1 23A 12V batteries and 6 AA batteries Inner Batteries Remove four screws from the battery cover 14 on the back of receiver unit Install 6 AA batteries into the battery compartment 13 and replace battery cover External SLA Battery optional Plug alligator clip wire into the external battery jack 10 and use the red alligator clip to connect to the positive anode terminal on the battery and use the black alligator clip to attach to the negative cathode terminal of the battery When an external batter
7. he field module receiver make sure the key switch is in the ON position and the three position switch is in the ARM position To fire a cue Press and hold for at least one second the appropriate button on the remote transmitter to fire the corresponding cue on the field module receiver The Cue FIRE LEDs on the field module receiver will light up as you press the number buttons on the remote transmitter indicating the fire signal is being received and the cue is being fired NOTE When the firing system is in the ARM status and once a specific cue has been sent the firing command it cannot be activated again for five 5 seconds Low Power Alarm When the power to the system has dropped to 6 5V or below the digital readout 11 will blink continuously no matter which position the three position switch is in If this occurs the batteries should be replaced or the external battery should be recharged The system may not work correctly or fire igniters reliably when the voltage being supplied to the system drops below 6 5V Digital Readout 11 When the three position switch 7 is in the LEARN or ARM position the digital readout 11 will display the indicated voltage of the active power source When the three position switch 7 is in the TEST position the digital readout 11 will display the last three digits of the ID of the receiver How to Use continued Wired Control Mode future use When the field
8. logy in consumer firing systems And when combined with our Falcon igniters you can put on a dramatic fireworks display just like the pros at a fraction of the cost Plus you get to watch your displays along with your guests Now there is no longer any reason to hand light your displays Do it like the pros at a fraction of the cost This convenient system is extremely reliable and has many benefits of more expensive professional systems FCC Certified FCC ID YMUT10012LN The range from the remote to the field module receiver is about 300 feet depending on surround ings This system is highly sensitivity with excellent anti jam performance It is extremely reliable and easy to use The RF transmission between the remote transmitters and receiver is very secure There are more than 1 000 000 address codes available for the transmitters and once a receiver is activated by a remote transmitter that receiver will respond only to the transmitter it has been mated to Transmitter comes with an on off switch for added safety and security You cannot inadvertently fire a cue with the remote power switch in the off position Turn the remote power on only when ready to fire The field module receiver has a 3 position switch for TEST ARM and power OFF LEARN Multiple MS12Q field modules receivers can be mated to a single MS12Q transmitter allowing a single remote transmitter to control multiple field modules receivers ar
9. oston LEARN position Press Press Press Press and hold the LEARN LEARN LEARN LEARN button for 3 button button button seconds rapidly rapidly rapidly SAFETY IS OUR MAIN PRIORITY REMEMBER SAFETY IS OUR PRIMARY CONCERN WHEN WORKING WITH FIREWORKS REMOTE FIRING SYSTEMS CAN ADD AN ADDITIONAL LEVEL OF SAFETY TO IGNITING FIREWORKS BUT THE RISKS OF ACCIDENTAL IGNITION STILL REMAIN EVEN WITH THE REMOTE FIRING SYSTEM S USE PLEASE MAKE SURE ALL FIELD MODULE AND REMOTE TRANSMITTER POWER SWITCHES ARE IN THE OFF POSITION RIGHT UP UNTIL THE TIME YOUR DISPLAY IS ABOUT TO BEGIN THIS NOT ONLY SAVES ON BATTERIES BUT HELPS TO PREVENT ACCIDENTAL IGNITION FROM AN INADVERTENT BUTTON PRESS PLEASE REVIEW OUR COMMON SENSE SAFETY GUIDELINES LOCATED AT http www fireworks us DISCLAIMER The manufacturers distributors and sellers of this device accept no responsibility whatsoever for any dam age injury or loss financial or otherwise resulting directly or indirectly from the use misuse function or malfunction of this device By purchasing and using this device you understand and accept this disclaimer Quantum Products Inc www Fireworks us www FiringSystems us Email sales fireworks us
10. y is connected to the system the inner batteries with be bypassed automatically Confirm normal operation of the field module receiver Step 1 Turn the safety key switch 6 to the ON position Make sure the three position switch 7 is in the center LEARN OFF position The digital readout 11 should display the indicated voltage of the active power source Step 2 Shift the three position switch 7 to the TEST position All 12 cue test LEDs 4 and all 12 cue fire LEDs 5 should turn on Additionally the digital readout 11 will display the last three digits of the of the ID of the receiver Step 3 Shift the three position switch 7 to the ARM position All 12 cue test LEDs 4 and all 12 cue fire LEDs 5 should turn off Additionally the digital readout 11 will display the indicated voltage of the active power source Step 4 Shift the three position switch 7 to the OFF center position IMPORTANT If any of the cue fire LEDs 5 remain on and all of the cue test LEDs 4 are off during the procedure of the steps above the cue is shorted out and cannot be used DO NOT connect any e match or igniter to the shorted out cue as the damaged cue will fire an e match or igniter without any operation of the system Discontinue use of the affected cue until the system can be repaired or replaced Before Use continued LEARN procedure You will need to go through the LEARN procedure before the field mo
Download Pdf Manuals
Related Search
Related Contents
Harbor Freight Tools 1 Horsepower Wood Shaper Product manual CC-Link System Optical Repeater Module User`s Manual EasyGrinder 3. - Optoma ASRock B85 Pro4 Quick Start Manual Guide d`installation rapide [suite] DINレールトランスミッタ M100 DR - メトラー・トレド - Mettler EVGA 512-P3-1300-EL NVIDIA GeForce 8400 GS graphics card Copyright © All rights reserved.