Home
POWER PRODUCTS
Contents
1. 7 5 kVA 630kVA _ ENGLISH gt Global Power Solution POWER PRODUCTS Ou sg EE 1 SO ESSE a E Wa lt J Ls NEI bay b La 1 NEUE y C MEE IRIS prr ee ively in generating set titiveness and quality has acquired skills recognized by all of i SDMO is now one of the w kVA lts teams spread over 3 production sites have skills at the leading edge of the new technologies and of manufacturing processes Each team works on a common data base and specializes in a range of standard products thus increasing its efficiency SDMO undertakes to supply you with a reliable innovative and quality electrical energy source to accompany you in each of your projects n the generating set specialist In order to provide you with proof of reliability SDMO has introduced a quality procedure Its careful compliance with this commitment has made it possible to obtain ISO 9001 certification For you this is the guarantee that delivery will take place on time with the best possible monitoring of your order The reputation for service quality acquired by SDMO all over the world is the result of this continuous search for improvement Now SDMO is represented in over 150 countries thought a network of agents distributors 8 subsidiaries all established in Great Britain Spain Belgium S
2. 1730 340 J290K 200 220 160 176 185 32 6 6068HF475 6L 106 197 6 7 LS 462 M5 2 37x1 11x1 48 1790 340 J300 K 275 303 220 249 937 42 6 6068HF001 6L 116 129 8 1 S 469 L9 2 90x1 30x1 68 2235 390 J400K 365 409 999 391 373 494 6195 HF070 6L 197 165 125 LS 479 VS2 3 16x 34x1 74 3040 470 J440 K 14001440 320352 373 532 625 O70 OL 127 165 i125 LS 479 VS3 3 16x 34x1 74 3040 470 GENERAL SPECIFICATIONS Genset specifications Engine M Vua Wb ddl Doe 230 V of Engine kW m Cons 3 4 genset PRPO 7 Engine type Cyl Bore Stroke Cyl TA Brand Type Dimensions EXP Ene Uh mm mm D Luk E dm 3099DH90 3L MA ECO32 3S 1 70x0 89x1 19 MONTANA Compact Version 100 1 Available in the following voltages 415 940 V 400 230 V 380 990 V 940 V 930 V 290 V 990 197 V 200 115 V 940 190V 230 115 V 990 110 V 9 Prime Power PRP 3 Generating sets equipped with TA LUFT certified engines Nox lt 4000 mg Nm3 CO lt 650 mg Nm3 HC 150mg Nm3 PM lt 130mg Nm3 4 The dimensions and weights are given for a defined generator according to the price list excluding options Version with canopy see page 9 5 Dry weight without fuel 6 PRP Prime Power is available for an unlimited number of annual operating hours in variable load applications in accordance with ISO 8598 1 A 10 overload capability is available for a perio
3. Fax 55 11 4053 2718 SDMO ARGENTINA Argentina Tel Fax 54 114 205 3005 SDMO ASIA PACIFIC PTE Ltd Singapore Tel 65 6419 3788 Fax 65 6419 3798 SDMO ENERGY Ltd UK Tel 44 0 1932 345 777 Fax 44 0 1932 350 033 SDMO INDUSTRIES IBERICA Spain Tel 34 93 586 34 00 Fax 34 93 580 31 36 SDMO NV SA Belgium Tel 32 3 646 04 15 Fax 32 3 646 06 25 SDMO LAGOS Nigeria Tel 234 0 1776 95 95 Fax 234 0 1 461 34 75 OFFICE SDMO ALGER Algeria Tel 213 21 92 55 84 Fax 213 21 92 47 76 S m y m EJ i E N v gt 2 a E s Ld b Y me b o IE I oN v 9 c v c No gt S a ud im V Y b d J5 a 9 P 2 o N d D E b d o v e L zd lt a I la z e z Q En Z is x e 1s d ux m o b ed m jg m gt a o U PE i V E Pi S4 E El lt 5 5 c o o Li c s Z 9 i lt o lt b o a Ld EJ o m gt Ly E o0 zo wiat o 2 m E sd iE m y i D I o c 2 lt iE Ss o Y Q N Y m I zd wA gt c me o b zd Ll lt Ep Y m E zd v Y 2 Y N 2 N T E N E me m o S lt 9 E me o i a O gt E EJ o ISO 9001 V U KAS SDMO Industries Sites in France SDMO Industries 12 bis rue de la Villeneuve CS 928
4. each side Number of doors 94 9 maintenance Lub oil drian pump EN 04 access Electric panel door o Road trailer for soundproofed canopy X Eye 1 57 in DIN german TR 21 TR 21 X Trailer Eye 2 68 in French o o X Eye 2 99 in NATO TR 25 TR 25 X Ball 1 97 Universal TR 26 TR 26 X Spare wheel kit jack TR 31 TR 31 X Standard X Impossible CN O4 Option code CN 04 Free option 1 Assembly by authorised SDMO personnel only 9 Option Sik for the canopy 126 y electrical panels CONTROL PANELS NEXYS TELYS KERYS M Q9 1 consult us MICS NEXYS PRESENTATION The Mics NEXYS SDMO s new entry level unit can run in automatic or manual modes Modular in design it offers high quality basic functions for the simplified and reliable control of your generator set Board lighting Hmergency stop button Indicator LEDs ON OFF keyed switch LCD display Safe ty fuse Scroll display button Generator stop button Generator start button Position of options Engine parameters Automation Standard O Option code e LCD Standard with LCD message X Not available 1 Choice is revised through programming The alternator s voltage reference connecting wire modification is necessary 9 The earth fault protection is ensured by one external module 5 Standard on Montana range For more information concerning the Mics NEXYS see the Nexys documentation NEX GB 2004 1 or contact your SDMO
5. pour pour J 990 K 4 Not available on J 300 K 5 Select NEXYS or TELYS Mics fitted with CB 19 Master Card 6 Level A canopies POWER PRODUCTS Discover our modular canopy concept and transparently appreciate its advantages HZ In addition to noise reduction this particularly economical concept enables you to optimise your generator set s footprint and to benefit from features such as easy handling and a retention bund CANOPY 227 CANOPY 126 CANOPY 127 ie 2 7 17 CANOPY 129 CANOPY 226 CANOPY 228 CANOPY 229 CANOPY 230 E SDMO GENSETS amp CANOPIES Type Dimensions Acoustic power 50 Hz Lxwxh m dB A Q m dB A 7m T 15 HK WT 5XO 72x23 80 8 70 8 T 20 HK 1 75x0 79x1 93 78 4 68 4 T 27 HK 9 06x0 9x1 49 81 71 PACIFIC T75K 1 75x0 79x1 93 70 1 60 1 T115K 1075x079 x 1 93 70 4 60 4 T 16K 1 75x0 79x1 93 70 7 60 7 T 22 K 9 06x0 9x1 49 A 61 J 33 2 06x0 9x1 42 65 J44K 9 06x0 9x1 42 63 J 66 K 9 30x1 08x1 68 70 JTK 9 30x1 08x1 68 70 J 88 K 9 30x1 08x1 68 70 J 110 K ele Nt dels 67 MONTANA J 130 K 3 51x1 90x1 83 68 J165 K p b OS 68 8 J 200 K 3 51x1 90x1 83 68 8 J 220 K ISIL ES 68 8 J300 K 4 00x1 38x9 13 69 5 J400K 4 48x1 41x9 43 66 5 J440K 4 48x1 41x9 43 66 6 V 220 K 4 00x1 38x2 13 0S7 V 275 K 997 390 4 00x1 38x9 13 3900 69 V 330 K 998 470 4 48x1 41x9 43 3980 70 V 3735 K 998 470 4 48x1 41x2 43 3910 70 ATLANTIC V 410 K 998 470 4 48x1 41x9 43 4390 69 5 V 440K 998 470 4 48x1 41x9 43 4390 69
6. rter operation Fressing this k ey prohibits t PROPERTIES operation of either of the instruments 9 screen lines for simultaneous network side and generator side voltage display The same applies to the frequency The 6 LEDs provide instantaneous information concerning the position status of one or other of the 2 sources along with any possible alarms or faults LED indicating the contactor s closed position ADDITIONAL PROPERTIES Communication In addition to a wired link for remote dry contact start up on all SDMO monitoring control modules Nexys Telys Kerys the TSI module possesses a CAN bus allowing it to communicate with the Kerys MICS This link allows the TSI to send to the Kerys all of the data concerning the network and the start up order following a voltage variation Short Term Synchronising An additional board available as an option allows e Short Term Synchronising on network substitution request e Short Term Synchronising on return to mains As from June 2005 E SDMO SERVICES CHARACTERISTICS In order to provide you with faultless products SDMO has created a Services department with three major missions Technical assistance Technician and agent training d Spare parts SDMYON technical assistance department is committed to providing an efficient and effective after sales service program Through our mass network of distributor and agents users are guided and supported towards the
7. 352 59 5 TAD 1949 GE l V500K 455 500 364 400 392 69 2 TAD 1640GE amp VssoK 500 550 400 440 430 75 4 TAD 1641GE 6l V 30K 573 630 458 504 485 85 TAD 1649GE amp m un IE E IE E E E E p ue T 1 Available in the following volage 415 240 V 400 230 V 380 220 V 240 V 230 V 220 V 220 127 V 200 TI5 V 240 190V 230 015 V 220 TlO V 2 Prime Power PRP 3 Generating veh equpped with DL TA LUFT certihed engines Nox lt 4000 mg Nma CO 650 ma Nma HC 150mg Im3 PMecT30mg Iem3 4 The denernions and weights we gen lor a dehned generator according to the price lint excluding options Verion with canopy we page F 5 Dry wegh without huel 6 PRP Prime Peer i avadabsle ler an unkmited number of annal operating houn in varable load appiscabom in accordance with 5O 8528 1 A X overload capability n available for a period of hour within 12 hour pened ol opatan in accordance wth ISO 30461 7 ESP The wandby power rating n applicable lor supplying emergency power in wanable load applcatiom m accordance wath ISO 8528 1 i Cherload n not alowed w 2 NL 8 Standard Motor Alternateur Genset Exhaust Oil Cooling Starting Fuel Accessoires 4 stroke liquid cooled diesel engine Mechanical governor Electronic governor Standard air filter Air filter with replacable cartridge 0 Coolant heater 220 240 V without relay Coola
8. 48 29228 BREST Cedex 2 France Tel 33 0 2 98 41 41 41 Fax 33 0 2 98 41 63 07 Telex 615 092 F http www sdmo com 05 2005 GB 50 01 SDMO RCS Brest 548 202 985 vo Do not dispose of on the highway Catalogue price given for information 1 26 S A S au capital de 17 066 590
9. 9 V 500 K 999 500 5 03x1 56x9 43 4660 69 7 V 550 K 999 500 5 03x1 56x9 43 4795 69 7 V 630 K 930 610 5 03x1 69x2 66 5300 99 5 81 8 TAS Type Dimensions Acoustic power 50 Hz Lxwxh m LWA dB A im dB A 7m T 11 5 HKM M7 SXOT 21 23 96 80 8 70 8 T 5 5 KM 1 75x0 79x1 93 86 70 1 60 1 PACIFIC T 9 KM U7 5X07 2x1 23 86 1 70 4 60 4 T12 KM 1 75x0 79x1 93 86 5 70 7 60 7 T 17 KM 9 06x0 9x1 42 950 7 61 MONTANA J24M 9 06x0 9x1 42 89 74 9 65 1 Dry weight without fuel SDMO makes its generating sets comply with the directive 2000 14 CE and the i validation of its products is controled by an approved laboratory the CETIM EQUIPMENT 227 228 229 230 Mounted soundproof canopy Esi Soundproofed canopy kit X Colour Black blue RAL 9005 RAL 5007 e Canopy Black end specific colour caution delay 8 weeks min CN 08 Modular sheet steel structure e Phosphate priming followed by anti corrosion polyesterpowder coat o Flexible seals between body sections e Central lifting eye lifting point Q Baseplate with retention tank FDO4 Lifting Fluids secondary containment system X Double wall and great autonomy FDO2 Simple baseplate CN 05 Lockable doors with single key o Lockable control panel e Exterior emergency stop button o S f Access to fuel oil and battery through lockable doors e atety Protective mesh for rotating parts Silencer inside canopy e Galvanised sheet metal air outlet duct CN 03 Sockets panel 400 V Tri N X Easy Doors on
10. benefits Failure troubleshooting assistance aintenance assistance logs automatic Email etc Electrical and mechanical parameter graphs and OSs ead impact management Addition of extra logics with no external tools Active poxer Active and reactive reverse power Homopolar current and homopolar current directive Homopolar oltage and restricted earth Vector jump mini Z and dF dt Synchronisation Manual and automatic Frequency and voltage equalisation rmation check the Mics KERYS documentation or contact your SDMO sales representative For further info LES PANELS AND AIPR CHAF ODU IST CS gt Power modules mounted in panels Up to 630A the power modules are integrated into the panels The cable flexible connections between the panel and the alternator are fitted within one isolating cable protection POWER SECTION 3 poles 4 poles Modular circuit breaker from 10A up to 125A X Compact circuit breaker 160A and 250A O Compact circuit breaker 400A and 630A e O m Standard O Option code X Not available AIPR Above 630A power modules called AIPR are separated from the control command These panels are fitted on the generating set frame and connected to the alternator RATING 800A 1250A 1600A With a front manual command 3 poles circuit breaker compact type e 4 poles circuit breaker compact type O Opti
11. best answer to their questions Whether a user is directed towards a regional agent or if on site maintenance is required all situations are taken intoaccount in order to provide the best possible service in the shortest time frame m i Rs i In order to optimise the performance levels of the SDMO generator sets the Services Department possesses a training centre in Brest near to our production plant and designed for our customers and agents technicians who service our products Syllabus Generator set operation and maintenance Mechanical engineering Electricity topped up with specific one off courses performed on site and on request Each year 2200 man days of training dispensed by specialists are dedicated to the acquisition and updating of SDMO product knowledge GenPARTS mum The Spare Parts Department represents 25 000 references of which 9 200 in stock on 4 5 km of shelving In charge of managing stocks and procurements the SPD is also responsible for service traceability and ensures the ongoing improvement of quality It is with these points in mind that the Spare Parts Department created GENPARTS an SDMO spare parts brand The SPD also provides our customers with interactive computer assisted spare parts selection tools SUBSIDIARIES SDMO GENERATING SETS Inc USA Tel 1 305 863 00 12 Fax 1 305 863 97 81 SDMO DO BRASIL Ltda Brazil Tel 55 11 4053 2700
12. d of 1 hour within 12 hour period of operation in accordance with ISO 3046 1 7 ESP The standby power rating is applicable for supplying emergency power in variable load applications in accordance with ISO 8598 1 M Overload is not allowed Standard X Impossible ATLANTIC V275K rs ATLANTIC V 440K a mm DLI A CEL GENSETS s L F i j a T m umm GENERAL SPECIFICATIONS ATLANTIC Genset specifications Engine Alternator Compact Version Type 400 230 V specifications Stroke Cy TA Brand Type Dimensions exhi Tank mm L Luft Lxwxh m ko D 73 e LS 135 469M5 955x130x1 59 2090 390 135 73 LS 469 L 2 90x1 30x1 69 9950 390 100 94 e is 462VL12 316x134x1 76 9850 470 120 94 LS 479 VS9 3 161 34x1 76 9780 470 150 19 1 47 9V93 3 16x1 34x1 81 3190 470 150 19 1 479 VS 3 316x134x1 81 3938 470 165 16 1 LS 47285 3471639 07 3470 500 165 161 LS 479 M7 3 47x1 63x9 07 3600 500 165 16 1 LS 4919 347163907 3740 610 ol genset P ESP PRP ESP Engine type Cyl V220K 200 290 160 176 178 31 8 TWD740GE 61 VgmK 250 275 900 990 217 37 5 TAD740GE amp V330K 300 330 240 964 302 55 TAD941GE amp V3sK 341 375 972 300 392 55 TAD941GE amp V410K 375 413 300 330 393 55 TAD 1941GE l V 440K 400 440 320 359
13. he MICS y one external module connected to the CBI2 DS mains detection is proposed as a bgse in the x Choice is revised throug 7 NF E37319 standard MICS KERYS PRESENTATION The Mics KERYS is a user friendly and intuitive tool that possesses a very broad range of features It is fitted as standard on all generator sets intended for synchronising applications and can be fitted as an option on all of our other applications In order to meet all of the requirements of low or high voltage power plants the Mics KERYS can be fitted into a control desk directly onto the generator set or in a separate cabinet lt complies with FC UL and CSA standards Control keypad with display LEDs Manu mode selection Display screen Colour graphical display Stop mode selection Auto mode selection Open Close GE circuit breaker Activate Deactivate test Open Close network circuit breaker LED test Stop horn ouch screen Dimensions 154 x 86 mm Erase anomalies Configure tion keypad For configuration navigation Directional keypad with activity LED and direct access to screens The Mics KERYS is available in two versions The basic GUI Graphical User Interface is made up of a monochrome LCD screen and a function keypad The top of the range Mics KERYS tactil version possesses a TFT colour touch screen Both of these versions provides a user friend
14. ingapore Argentina the United States Brazil Nigeria and a liaison office in Algeria SDMO devotes its energy to accompanying you in the successful completion of each of your projects all over the world SDMO is committed to supplying you with the energy source which suits you where you need it e Agents Distributors e SDMO Stocks e Implantations SDMO Head office MITSUBISHI PACIFIC T11 5K PACIFIC T16K je gummi sdmo com GENERAL SPECIFICATIONS PACIFIC Genset specifications Engine dli Compact Version Tyee 400 230 V9 specifications kVA Range of Cos Q 0 8 Engine genset pppo 5 Engine type Bore Stroke Cyl TA Brand Type Dimensions Weigh Tank L h mm mm D Luk Lxwxh m kg L L3E SDH 0 95 FT2MBS 1 41x0 72x1 03 50 53L9 SDH 5 78 cu ps ECO3 2L 1 41x0 72x1 05 50 S4L9SDH 4L 78 92 1 8 ECO 8 9L 1 41x0 72x1 10 100 3000 rpm TI5K 68 75 55 6 67 17 LES 3L 76 70 10 MA ECOS9S 1 41x0 79x 03 307 50 SOO rom TISK 105 15 84 92 151 25 Sa2SD 3L 78 92 13 MA ECOSIL 14hk079405 387 50 rpm P TaK fis 16 16 ig8 151 34 SalesD aL 78 92 18 MA ECO28S 140 724 05 497 50 T22K 90 99 16 I76 9 7 47 S4O9SD 4L 88 103 95 MA ECO281L 1 70x0 89x1 12 560 100 GENERAL SPECIFICATIONS PACIFIC Genset specifica
15. ion level A Multilingual documentation level A extra copy German version level A extra copy English version level Boo English version level C Standard tool set Standard tool box GENSERVICE Spare parts Air filter with replacable cartridge Standard X Not available O Different options available EN O1 Option code FD O1 Free option Standard and Options Protection mesh for fan and revolving parts MONTANA EN 01 o EN 09 EN 20 x x xx x 0e00 06 77 X xe x E EL o o o e e e e o o ES 04 M ES S ES 2 EN ES EN ES o EN 07 E 07 EN 12 ENIES EN 08 EN 08 EN 09 EN 09 EN 13 EN 13 EN 10 EN 10 CEL 02 za 09 eo e FD 11 FD 11 11 FD 11 e o o e EN 14 EN 14 EN 14 EN 14 Ry 192v 12 V 24 V e e o EN 15 EN 15 EN 15 EN 15 EN 16 EN 16 EN 16 EN 16 AD12 AD12 AD 91 AD 91 AD 29 AD 29 AD 31 AD 31 AD 41 AD 41 AD 05 AD 05 AD O6 MILADO O O Technical documentation level B W separator fuel prefilter 1 Impossible on T 16 K 2 Not available on J 44 K IP21 3 Only on J 200 K and J 300 K documentation including maintenance manual and diagrams genset user manual and description of switchboard genset installation guide 7 French english spanish 8 Level B documentation including level A list of engines and alternator parts english only 9 Level B documentation including level B workshop manual english only 10 19 V
16. lization Plug preheating ATS changeover presence choice Mains contactor position return Generating set and mains contactor position return Generating set contactor manual closing Generating set contactor manual opening Starting on clock External starting order Mains sensing 3 ph Test LEDs Fault reset External AMF predisposition 3 phase with or without neutral 2 phase or single phase use 12V battery charger GES Pack fitted inside the genset Differential protection with time and sensitivity adjustment Alarm hooter elys 2 e choice Marm or hi is programmed throug 4 e wi Oar o B19 card cal pa is also neede 3 The earth fault protection is ace S module can be moul Bh in the panel PARAMETERS KEYS 8 DISPLAY LEDs alarms faults statuses Oil pressure fault R 9 Water temperature fault R 3 Failure to start fault R 4 Overspeed fault R 5 Set ready to output G 6 Charging alternator fault R 7 General alarm Y 8 General fault R R red G Green Y Yellow 2 generating SET REGULATION OUTPUT KEYS Pede dede NO NO hO WS Mec het Lue Le Peas GO YS 2 3 ee ie NS Ses ae ae ae S gt D pes on nN SY OOOOeOcOee eo0oooooooooceeeeeocooeoeeoeoeooo 1 Control and automatisms installed but necessity to have the option External AMF predisposition and the possible configuration of one parameter o t
17. ly configuration operation or diagnostic interface SPECIFICATIONS The Mics KERYS possesses all of the features of the Mics TELYS cf table page 13 ADDITIONAL SPECIFICATIONS Control Speed and voltage Frequency and voltage setpoint switching Frequency and voltage setpoint adjusment Active and reactive power setpoint adjustment Active and reactive power ramp up Active and reactive power distribution Active and reactive power lock out Manual speed and voltage control Synchronising A612 Generator set without grid A622 Generator set with ATS and grid no synchronising A633 Production plant without grid A634 Production plant with grid and ATS no grid synchronising A641 Generator set with permanent grid synchronising no ATS grid synchronising resale A642 Generator set with permanent grid Active and reactive energies Synchronism phase voltage and frequency deviation Voltage and current harmonics Protective measures Qverload short Line current diredtive Communication synchronising no ATS Grid synchronising OkW Neutral current Local or remote mode power cap on grid Reverse component On board Web site A651 Generator set with fading grid synchronising old back RS485 link and INS Ethernet local mode and Internet A661 Generator set with permanent grid remote mode synchronising and ATS Standard added
18. lys This software developed by SDMO enables the user to set up the dialog between the Mics TELYS panel fitted on our gensets and the PC type computer on which it is installed in order to control from a distance the operating system Depending on the configuration of your installation you can select from 4 types of connection the one that best suits your needs local mode supervision Switched Telephone Network remote management Ethernet remote management or SGM electronic surveillance For further information concerning Wintelys please contact an SDMO reseller eC eC e C e C e C e LCD e C e C o Q J A a er xe M e d o O O O O O o o o o o e e e O O o O card and t rough connecting of one tiny relay on the source inverter In the case whereby the source inverter is not chosen the MICS programming The alternator s voltage reference connecting wire modification is necessary 6 For details please consult us 4 electrica CQQUANTITIES AND ENGIN Oil pressure fault Water temperature fault Emergency stop fault Overload or short circuit alarm or fault Min max battery voltage alarm or fault Min max alternator voltage alarm or fault Min max alternator frequency alarm or fault Overspeed fault Differential relay present fault Differential triggering alarm or fault Automatic standby Automatic extinction 4 modes Engine stopping for cooling Voltage and speed stabi
19. nt heater 120 V with thermostat IP 23 single bearing alternator class H insulation Anti condensation heater Tropical impregnation Synchronizing C T 3 fonctions regulator PMG regulator Excitation AREP CE Electric panel compliance Compliance with CSA NRTL C marking Output breaker Fabricated all welded baseplate with anti vibration mountings standard colour RAL 9005 5007 black blue delivered in shrinkwrap Supplied with oil and coolant 86 F Lub oil drain valve diesel oil flexible Lub oil drain pump 9 dB A industrila grade silencer Silencer 9 dB A not supplied Silencer 9 dB A adjustable not compatible with CEL 02 99 dB A residential grade silencer 40 db A critical grade silencer 40 cm extension Exhaust outlet with flexible Protection mesh for hot parts CE Radiator for air on temp 118 F with drain cock depending on version Supplied without coolant Protection mesh for fan and revolving parts o Stone guard radiator outlet Starter and charge alternator Batteries with cables and battery tray Non supply of batteries and tray cables still supplied Battery isolator Inbuilt fuel tank Fuel inlet return connections no tank Automatic fuel fill kit for frame tank Automatic fuel fill kit for separate tank Retention bund Retention bund on DT W separator fuel prefilter Tank with retent Bund Retention bund alarm for separate tank Multilingual documentation level A extra copy German vers
20. on motorized control With 3 poles circuit breaker open type O With 4 poles circuit breaker open type O Others characteristics Voltage 208V 440V e o Bus bars e e Remote control terminal box O O O Protection index IP 07 IP207 IP907 Dimensions height mm 1090 1960 1960 width mm 560 665 665 depth mm 938 360 360 Standard O Option code The motorized remote control includes one XF coil one MX coil and one AC engine Only with the option motorized control NBIs PRESENTATION SDMO presehts a complete range of separate INBls Normal Backup Inverters This technical solution presents a large number of advantages both in terms of cost and of ease of installation e design of our boxes and cabinets allows extremely easy connection even to high cable cross sections The box s front panel no longer operis on only one side like a conventional box but on three sides thus providing full access to power equipment and terminal strip jumpers All of our boxes are either three pole or four pole e ISl module T ransfer Switch Intelligence i is fitted as standard to our whole range of Normal Backup Inverters whatever the rating of the inversion element from 95 to 3900 A 1 Switch over V On a base height 900 mm i e a cabinet height of 1600 200 1 Integrated into a cabinet on the ground THE TSI MODULE PRESENTATION Both innovati
21. ower in variable load applications in accordance with ISO 8598 1 Overload is not allowed Standard MONTANA J66K JOHN DEERE TELYS control panel optional MONTANA S J220K z priui Vw samo com GENERAL SPECIFICATIONS MONTANA Genset specifications Engine Alternator Compact Version Tee 400 930 V specifications kVA of Cos 0 8 Engine genset PRP ESP PRP ESP kW m Engine type Cyl Bore Stroke Cyl TA Brand Type Dimensions eigh Tank L h mm mm L Luf LxIxh m kg D J 33 3029 DF120 3L 106 10 99 X MA ECO 28 VL 1 70x0 89x1 12 740 100 J44K 40 44 32 35 364 84 3099 TF120 3L 106 10 2 9 MA ECO32 3S 1 70x0 89x1 12 820 100 J 66 K CO e 85356 12 4045 TF1 0 4L 106 197 4 5 LS 439M45 1 87x0 99x1 36 1090 180 JTK 70 77 56 62 6l 12 4045 TF190 4L 106 197 4 5 LS 439 L8 1 87x0 99x1 36 1110 180 J 88 K 80 88 64 70 73 14 4045TF290 4L 106 197 4 5 LS 439 L8 1 87x0 99x1 36 1110 180 J110K 100 110 80 88 88 16 5 4045HH90 4L 106 127 4 5 LS 449VS45 195x 08x 33 1290 190 J130K 120 132 96 106 106 18 5 6068 TF 290 TCE OG 27 NO LS 449 S7 2 37x1 11x1 48 1570 340 J165K 150 165 120 132 136 925 6068 HF1 90 6L 106 197 67 LS 449M95 2 37x1 11x1 48 1700 340 J 200K 180 198 144 158 163 34 5 6062 a ZO CE eere 1o7 rey IS 469 M3 9 37x111x1 48
22. sales representative E SDMO 10 g PRESENTATION A major component of our range of control units the Mics TELYS is a standard addition to our generator sets from 200 kVA upwards its user friendly interface and range of features allow careful monitoring of your installation LCD SCREEN incorpored backlighting featuring 8 lines x 21 characters 1 ON KEY with integrated LED after automatic extinction 15 PROGRAMMING KEYS NUMBER KEY PAD 0 TO 9 4 OPERATING MODE SELECTION KEYS with integrated selection LEDs 2 ERROR RESET AND LED TEST KEYS SPECIFICATIONS Line voltages in Volts Single voltages in Volts Phase currents in Amps Neutral current in Amps Frequency in Hertz All generating set states all starter phases Analogical indicator Ammeter battery Indication of engine speed Indication of battery voltage Elapsed hour meter Powering up Fuel solenoid operated valve control Starter control Plug preheating control Water preheating control Mains contactor control Generating set contactor control Oil pressure fault Water temperature fault Fail to start fault Overspeed fault Set ready for load Charging alternator fault General alarm General fault Panel lamp 22 dia STOP MANU AUTO TEST mode Generating set side contactor closed Mains side contactor closed Any faults or any alarms messages Standard O Option code LCD Standard with LCD message winte
23. tions Engine B dedi Compact Version Type 230 VO specifications Range of genset PRP Engine type Cyl Bore Stroke Cyl TA Brand Type Dimensions eight Tank L h mm mm D Luk Lxwxh m kgs D BG Tigre ws as se treo ome m io e MA DECOR vases se s 135 5KM 5 9 9 6 7 1 L ESD 3L 70 10 e ECOS IT A80 79x ir JO I 50 T 9 KM 7 8 8 6 10 3 9 5 S3L2 SD 3L 78 99 13 e 7 ECO28S 1 41x0 72x1 05 417 50 1500 rpm T 12 KM 11 12 1 15 3 4 S4L2 SD 4L 78 99 18 MA ECO28 IL 1 41x0 72x1 06 450 50 T 17 KM 15 6 17 2 921 7 4 1 S4Q2SD AL 88 103 25 MA ECO 8VL 1 70x0 89x1 12 580 100 1 Available in the following voltages 415 940 V 400 230 V 380 990 V 240 V 930 V 990 V 990 197 V 200 115 V 240 120V 230 115 V 220 110 V 9 Prime Power PRP 3 Generating sets equipped with TA LUFT certified engines Nox lt 4000 mg Nm3 CO 650 mg Nm3 HC lt 150mg Nm3 PM 130mg Nm3 4 The dimensions and weights are given for a defined generator according to the price list excluding options Version with canopy see page 9 5 Dry weight without fuel 6 PRP Prime Power is available for an unlimited number of annual operating hours in variable load applications in accordance with ISO 8598 1 A 1096 overload capability is available for a period of 1 hour within 12 hour period of operation in accordance with ISO 304641 7 ESP The standby power rating is applicable for supplying emergency p
24. ve land original in its design it is perfectly adapted to applications in which transfer of the main source to the replacement source is central to the correct operation of your facilities Intuitive and easy to use this module is remarkable in that it is automatically configured in the presence of network side voltage By simply pressing the AUTO key the following parameters are configured Network voltage type of use min and max voltage threshold min and max frequency threshold Electronic power source switching allows it to permanently self power itself SCREEN Validation ke NAVIGATION and SELECTION integrated backlight with two 16 eys character rows used for browsing through the different ROTOPH A SE LED electrical variable screens or for complete module configuration to customer Indicates the direction of rotation specifications of inverted phases Test Source Status LED used to simulate generator set start up with possible complete switch over Three colour LED symbolising the source s status sequence Off No voltage ke Green Voltage present Auto k ids automatic module Orange Alarm configuration for automatic operation on mains Red Fault power cut or voltage drop ey 1 Forced source 1 operation ey 2 Forced source 2 operation ock out key used to lock inverter operation Pressing this key prohibits the operation of either of the instruments Padlock key usq to lock inverte
Download Pdf Manuals
Related Search
Related Contents
Spectracide HG-95684-2 Instructions / Assembly (各部の名称 Samsung GT-E2152 Benutzerhandbuch Guide d`utilisation - Crédit Agricole d`Ile de France Bosch HBL8461UC Product Information Guardian Technologies R3010 User's Manual 取扱説明書 - Panasonic Mode d`emploi Conceptronic lance le YuiXX, doté du CONTENTS: SPECIFICATIONS Copyright © All rights reserved.