1. Copyright Visage Imaging GmbH 9 30 V68 00 Feb 2015 Visage 7 Release Notes Version 7 1 6e The trigger for prefetching of prior studies can now be limited to the insertion of only new studies i e studies that are not older than a configurable amount of time 12333 7 1 6d Access via mobile client can be controlled based on version of the connecting mobile client app 12570 7 1 6d Patients with an exam scheduled within the next 3 days will be kept in online cache 12408 7 1 6d Fixed issue with client update via MSI installer 12525 7 1 6d Fixed issue with displaying reports stored on master in certain partner system configurations 12295 7 1 6d Fixed issue with study label assignment on installations with partnered systems and separate database servers 12321 7 1 6d Fixed issue with Study Navigator and vscontrol option startinviewer never 12587 7 1 6d Fixed issue with DICOM printing and top and bottom viewer texts 12320 7 1 6d Fixed issue with splitting an image into a new series via QA 12327 7 1 6d Fixed issue with broken desktop link after client setup 12674 7 1 6e Referring Physician Improved login with secure web access e g SiteMinder 11961 7 1 6b 12535 7 1 6d Small improvements of Media Viewer 11935 11943 7 1 6b Version 7 1 5 Radiologist Structured full resolution browsing of image quadrants in mammography and tomosynthesis 9045
2. 0 9 _ and are safe to use 482 e Changing the password in a Visage Client that connects to the Visage Server using IWA in an Active Directory setup might result in a soap error after a few minutes This is caused by cached credentials on the client that still contain the old password A workaround is to lock the client computer and to unlock it again Then the new password must be provided and the credentials are synchronized with the Active Directory 7961 e vscontrol only works correctly if the firewall does not block the vsclient exe process For the windows firewall this means that the computer administrator must insert vsclient exe into the firewall exception list 3275 e Subtraction of volumes is only possible inside a time series 3554 e Animated image display via the Cine tool card gives refresh priority to the active cine viewer For high frame rates this can result in lower refresh rates in other viewers For example during animated browsing of an image stack the corresponding scout line in another viewer might not be updated for every animation step 8748 Copyright Visage Imaging GmbH 27 30 V68 00 Feb 2015 Visage 7 Release Notes Version 7 1 6e e Under certain circumstances selecting structures by point and click is not possible In this case please select them from the list in the Structures tool card 3715 e Sending an e mail link immediately after loading a session might not be possibl
3. D eer home Visage Release Notes Version 7 1 6e Visagetg Al Copyright Visage Imaging GmbH All rights reserved Document Version 68 00 Feb 2015 Visage 7 Release Notes Version 7 1 6e Table of Contents 1 What s NEW TE E 4 VC EL Ia E ER E A S E E A A T st obeaivsoeestisseepsandecteades so ceeaassleeeeasstenean test 4 M rsion Zeene euer Eeer 10 Version e EE 15 VErSION Ti EE 17 Version ER ET 21 VC EL E ER E 24 2 Supported Client Operating Systems 26 WINDOWS EE 26 MacOS K aaronii ee eege 26 3 Restrictions and Known Issues sisi 27 Visage 7 CONE sessiiinnsdnisia tie henri ner ae tte ere en tnn en emmener t distante 27 Visage 7 SERVER se EE 28 4 Important Server Installation Notes 29 5 Regulatory Informatio ssas raseras ransas AE EAN ANEN KANSAE SENASA A Taa 30 Copyright Visage Imaging GmbH 3 30 V68 00 Feb 2015 Visage 7 Release Notes Version 7 1 6e 1 What s New in Visage 7 This section describes the relevant changes and improvements in the latest software versions of Visage 7 Each release provides several significant feature enhancements and improved usability and performance of the overall system The description of changes is grouped by clinical roles Radiologist Technologist RIS PACS Administrator Referring Physician Version 7 1 6 Radiologist Multi tabbed Epic EHR integration Visage 7 supports concurrent tabbed sessions with tight bi dire
4. Viewer texts for display of mammography images make better use of screen space and clearly indicate laterality and plane of projection 10034 Non top level enhanced and unknown DICOM tags can be displayed in viewer texts 11482 11830 7 1 5e Performance improvements for loading of large image volumes e g from DBT 10642 Digital Breast Tomosynthesis New position indicator replaces orientation cube and shows position of currently displayed slice image in DBT volume 9330 L MLO Breast Tomos Copyright Visage Imaging GmbH 10 30 V68 00 Feb 2015 Visage 7 Release Notes Version 7 1 6e e The new Balloon Tool enables definition of 2D and 3D structures by image aware interactive inflation of a 2D contour 10487 e Initial tool for defining 2D and 3D contours can be configured per user or protocol 9325 e The study navigator now has a filter as you type field 10902 Only studies matching the text typed into this field are shown Currently loaded studies always remain visible Matching is performed regarding study date study description modalities accession number or patient identifier Study Navigator Filter Chest Study Date Study Description 2010 Aug 24 CR CHEST 2010 Sep 06 12 41 02 CR CHEST AP LAT 2010 Aug 30 10 26 03 CR CHEST 2010 Aug 29 22 48 13 CR CHEST 2010 Aug 28 15 48 52 CR CHEST AP LAT 2010 Aug 25 11 04 22 CR CHEST 2010 Aug 24 03 46 44 CR CHEST e Search preset
5. 2D images and 2D viewers with the restriction that 3D structures cannot be defined there 11232 New tool for in plane image rotation in 2D and MPR viewers 11259 Several usability improvements when running the thin client on very high resolution displays 10864 10872 10874 10875 Legacy Web client supports Internet Explorer 11 11742 7 1 6b Several improvements to the standard set of hanging protocols 11243 11643 11924 11948 11986 12000 7 1 6b 12245 7 1 6c 12289 12434 12478 7 1 6d Acceleration of client startup 11782 7 1 6a 11979 7 1 6b 12113 7 1 6c Copyright Visage Imaging GmbH 5 30 V68 00 Feb 2015 Visage 7 Release Notes Version 7 1 6e e Various improvements of thin client stability 11361 11617 11723 11714 11848 11872 11904 11907 11957 7 1 6b 11806 11846 12129 12155 12231 12252 7 1 6c 11572 12001 12230 12345 12346 12347 12406 12409 12415 12420 12421 12427 12432 12449 12496 12539 7 1 6d e Annotations of 2D freehand ROls now display the circumference of the contour 12454 7 1 6d e Annotations of 2D elliptical and freehand ROIs now display the effective diameter of the contour 11372 7 1 6d e Tools for annotations and simple measurements can be configured to stay active until explicitly deactivated 11403 7 1 6d e Viewer texts can now display the current view direction as standard angulation cranio caudal an
6. Fixed issues in the interface to disc producers Epson Rimage 10489 12135 7 1 6c Fixed possible crash after printing image set 11803 7 1 6a Fixed potential client crash on QA delete 11840 7 1 6b Fixed potential client crash on QA series move if source and target study are identical user error 11850 7 1 6b Fixed issue with groups assignment after splitting a study 11921 7 1 6b Fixed issue with editing an existing patient via QA 12329 7 1 6d RIS PACS Administrator Significantly improved backend throughput supporting large scale enterprise imaging volumes 11217 11569 11871 12038 12306 12324 12331 12422 7 1 6d Extended modality work list to handle many modalities at various locations 11396 12394 7 1 6d Improved and extended handling of HL7 messages o ADT_A18 messages for patient merge are processed 11344 Support for more messages added 11347 PV1 segment in order messages can be optional 11348 ADT messages containing custom Z segments are accepted 11405 HL7 reports with data type ST in OBX 2 are accepted 11408 Repetitions for OBR 32 Principal Result Interpreter and other fields are allowed 11409 ADT patient merge message also updates RISPatient and RISOrder table 11427 Patient ID handling improved 11413 Messages with non standard LAN segment are accepted 11422 ADT messages are applied to all patients with the specified patient ID 11489 Study date fi
7. be initiated via the File menu in the View and Export screens 8061 Improved handling of snapshots in clipboard Whether a snapshot is copied automatically to the clipboard can be controlled by a user property 10142 10143 7 1 3d RIS PACS Administrator Support of reports sent via HL7 ORUARO1 messages 8896 8965 8966 9184 Visage receives reports via HL7 ORU RO1 messages and matches them to the respective studies Matching takes also place if studies arrive after the respective reports Storage of matching reports and studies is handled jointly i e if a study is deleted the matching report is also deleted Sending out HL7 messages 8902 10052 7 1 3c Visage provides a central queue for outgoing HL7 messages Messages will be resent if delivery fails The maximum number of retries and the time intervals between the retries are configurable through the Visage 7 administration interface A DICOM Modality Worklist can be provided based on information received via HL7 8972 Support of multiple patient IDs for the same patient 9037 Notifications about identity of patient IDs are received via HL7 Support for Issuer of PatientID for handling IDs from different issuing systems 9037 Copyright Visage Imaging GmbH 19 30 V68 00 Feb 2015 Visage 7 Release Notes Version 7 1 6e Media Export supports the Epson disc producer station 9342 Backend setup allows running the database server on a sepa
8. install MacOS X 11936 7 1 6b New Event Hook OnClientExit 11522 7 1 6c OEM passwords are supported for AD users 11851 7 1 6b Multiple issues with thin client control via OEM interfaces fixed 11433 11896 11968 7 1 6b 12103 12153 12154 7 1 6c Accession number is sent when loading saved session via Medicalis 12151 7 1 6c e Improved integration with Acuo archive 11438 11749 7 1 6a 12290 12419 12519 12576 7 1 6d e Improved import of DICOM data O Auto routing of images received by DICOM portal can be disabled despite Auto routing rules being active 11736 Parameters can be changed without restarting the DICOM Portal 11977 7 1 6b Issue with importing presentation states fixed 11897 7 1 6b Issue with nonstandard image content time fixed 11898 7 1 6b e Enhanced volume conversion O O O O Support for Toshiba enhanced DICOM data added 11276 Support for NM multi frame images added 12045 7 1 6c Handling of gantry tilted CT images improved 11608 7 1 6c Issue with RLE compressed volumes fixed 12023 7 1 6b e Fixed issues in quality assurance QA O O O O Study description is taken from correct HL7 field in automatic QA 11838 7 1 6b Processing of the result of QA jobs fixed 11869 7 1 6b Automatic QA for white space patient name change fixed 12208 7 1 6c Fixed logging issue of Manual QA when dialog is closed prior to comple
9. large images e g mammography or ultrasound and avoids memory fragmentation issues A single click client update mechanism was implemented It is fully integrated in the application and replaces the old update mechanism via the download page The new context aware online help introduced in Version 7 0 11 is available in German as an additional language besides English The new tools Next Study from Study Browser and Previous Study from Study Browser allow loading the next or previous study from the Study Browser list directly from the View window 7967 8011 The new tool Reset Dictation was added to the ProMedicus RIS Integration toolbar It allows discarding an already dictated report from the currently loaded study A RIS client update may be required for this feature to work 8018 Support for 2D images was added to the Statistics tool card 7306 A button for toggling R2 Breast CAD findings was added Issue with CAD performed on prior and shown on current study was fixed 7619 7741 The manual calibration of an uncalibrated image can be removed again 7628 Issues with zoom level and field of view of US images were fixed 7826 7827 Issue with linking in connection with the Lesion tool was fixed 7749 Issue with multiple studies or series selections when double clicking in Study Browser was fixed 7253 Issue with updating placeholders in report templates was fixed 7730 7784 Issue with loading cert
10. order If a patient with this patient ID exists already but has different patient level attributes the replacements are logged Event logging of failed login due to outdated client version has been improved 10626 Fixed issue with error logging if partner backend is not accessible 11081 The backend status check reports the number of rejected input files store failed but will not trigger an explicit warning 11154 Storage manager handles invalid date formats more tolerantly Manual QA is still required after import 10147 Various robustness improvements regarding treatment of invalid DICOM data 10367 10866 10986 Considerably reduced memory footprint of exconverter processing large enhanced DICOM files 10584 The list of demographic tags relevant for de identification can be configured on system and user level 10256 Abstract tag TimeSeriesNumber enumerates the time series of a study starting with 1 and sorted by the time stamp of the first phase 10486 Improved flexibility of rules for automatic loading of prior studies 10088 Maximum number of studies can be specified per rule The oldest prior i e baseline study can be chosen explicitly Copyright Visage Imaging GmbH 14 30 V68 00 Feb 2015 Visage 7 Release Notes Version 7 1 6e Patient matching for prefetching can be based on patient ID only irrespective of the storage manager s configuration 10870 Setting property Ul ShowStudy
11. 247 7 1 6d Vertical alignment and zoom synchronization of mammography images displayed by different viewers has been added to the Quadrant Navigation tool Exclusion of certain special images from this functionality can be configured 10819 7 1 6a 11878 12025 7 1 6b 12108 12176 12254 12008 7 1 6c 12442 12257 12502 12537 12595 7 1 6d Laterality orientation labels for mammography images can now be displayed at the top centers of the respective viewers 11985 7 1 6b 12242 7 1 6c DICOM MPEG4 videos are handled by the PACS component and can be watched through the thin client 11430 11431 7 1 6a 11842 11980 11999 7 1 6b Copyright Visage Imaging GmbH 4 30 V68 00 Feb 2015 Visage 7 Release Notes Version 7 1 6e Toggles for primary and overlay data in fusion display can be accessed via keyboard shortcuts 12132 7 1 6c Most of the search fields in the study browser accept a list of patterns separated by or 12173 7 1 6c 12355 7 1 6d Improved strategy for placing text labels of measurement tools 11996 7 1 6c Date range preset buttons in Study Browser and Quality Assurance screen are user configurable and support a broad variety of relative time intervals 12018 7 1 6c Capabilities of the Link Scrolling tool have been extended to linking 2D and MPR viewers The tools usability has been simplified for obvious cases 11834 7 1 6b 11880 12137 7 1 6
12. 3 30 V68 00 Feb 2015 Visage 7 Release Notes Version 7 1 6e Improved diagnostic reporting infrastructure for multiple partner systems 10705 10797 10685 Report templates located in the VisageLocal directory are synchronized between partner systems 10499 New mode for handling presentation states To every loaded series the most recent relevant PR from the same study is applied automatically Mode can be activated via system user property 10921 HL7 Overlong study descriptions from order messages are truncated to the allowed length of 64 letters 10894 HL7 Fixed issue with updating patient ID via order update message 10896 Loading data via vscontrol can be repeated after completion of the previous loading procedure 11026 Fixed issues with dialogs displayed by vscontrol 11153 Improvements in the audit trail 10054 10898 10895 Detailed audit trail event for study deletion via Study Browser Information about modified study level tags in event HL7 Edit Study Events HL7 Edit Study and HL7 Edit Patient have been renamed to HL7 QA Edit Study and HL7 QA Edit Patient and do not contain a message type anymore They are logged only if actual database changes were performed o Patient level changes induced by an HL7 QA Edit Study message are logged with an additional HL7 QA Edit Patient event o Event ManualQAAssignOrder always includes the patient ID of the target patient specified in the
13. 4a Improved media export on Epson disc producer 10426 7 1 4b RIS PACS Administrator New user level permission for remembering password in login dialog 10135 10373 10436 7 1 4a Event hooks are scriptable now 10611 7 1 4c New command line options for vscontrol that allow loading of additional image data similar to Add to View in the study browser window 10318 Added support for Issuer of Patient ID to vscontrol 10610 7 1 4c Added support for RLE encoded volume files to render server thin client 10871 7 1 4d Copyright Visage Imaging GmbH 16 30 V68 00 Feb 2015 Visage 7 Release Notes Version 7 1 6e New option to prevent sending of ACK in HL7 communication 9981 Several improvements in quality assurance QA 10106 10246 10292 10293 10325 Support for more than 10 thin client user levels 8156 Improved compression settings for high bandwidth network type 10327 Enhanced support for multi frame images 10272 10274 10303 10304 Several improvements in event logging and Trace Log tool 9771 10085 10471 10475 10478 10492 10493 7 1 4b 10615 7 1 4c Password change is applied on all partner systems 10528 7 1 4b TCP receive and send buffer sizes configurable 10442 7 1 4a Fixed issue on ignoring own AE title for C Move 9920 Fixed issue on data migrator stopping when database is inconsistent 10287 More robust backend setup 9921
14. 9973 10007 10044 10285 10286 Referring Physician New token based image access via embedded links in reports 10239 10247 10248 10249 10250 10251 10252 10385 10387 10427 10439 10443 10447 7 1 4a 10473 7 1 4b Fixed issues with black thumbnails and zooming in Media Viewer 10418 10581 7 1 4b Version 7 1 3 Radiologist Improvements for Lesion Tracking Load a particular study by dragging its column head from the Lesion tool card into a viewer 9378 For lesions that have been segmented in a PET series the maximal SUV is shown in the Lesion tool card and in the resulting report 9351 Lesion classification via function keys F1 F6 in viewer as well as in Lesion tool card 8776 Lesion defining tools can be configured for single use The lesion defining tools Segment Lesion Measure Lesion Measure Lesion 2 Diameters and Mark Lesion which are available while the Lesion Tool is active stay active until another tool is chosen By setting the new property Tools Lesions Tool Type to Trigger this behavior can be changed to single use i e the tool is automatically deactivated after a lesion has been defined This facilitates workflows with frequent changes between lesion defining and slice browsing 9395 Improved column handling in Study Browser 9182 Manual changes to column order width and visibility as well as the choice of sorting column are remembered from session to sessio
15. Navigator to ON_OEM_CALLS_ ALWAYS applies to calls via PMCONTEXT as well as via vscontrol 10542 Whether the Windows taskbar is hidden during full screen mode can be configured via the monitor configuration dialog 10724 Fixed issue with deselecting media data for DICOM printing 11119 Relevant length unit is explicitly specified in printer media configuration dialog 10508 Fixed issue with specifying a minimal allowed password length 10056 Fixed issue with communication between a Windows render server and a network share based archive 10490 Fixed issue with closing database connections 10901 Backend status page reports whether a temporary license is about to expire 10177 7 1 5a 11250 7 1 5b Fixed issue with receiving the same DICOM image multiple times leading to failure in DICOM printing 11223 7 1 5a Access via DICOM query and retrieve can be restricted per AET and user group 9253 7 1 5c Fixed issue with ungraceful termination of the render server 11254 7 1 5c Fixed issue with Visage Ease and queries on partner systems 11256 7 1 5c The initial value of the Do not archive toggle in the De identification and Teaching Files dialog is controlled via a backend configuration The factory default is to not archive de identified copies 11236 7 1 5c Robustness improvement of Fast File Server component 11284 7 1 5d Improved handling of passwords with unsupported character
16. ain RX studies was fixed 7816 Several issues were fixed for improved stability and performance 6802 7346 7612 7727 7773 7808 7861 7910 Technologist Support for defining an active viewer in the same layout was added This allows updating the active viewer by selecting the series without switching the layout 7698 Support for RF image type was added to plain film protocols 6443 The frame rate of cine animations can be controlled in the Cine tool card Performance of DICOM import from CD DVD was improved 7609 7647 The Media Viewer loads images from CD DVD much faster Snapshots are calibrated by adding the pixel spacing tag 7625 Copyright Visage Imaging GmbH 24 30 V68 00 Feb 2015 Visage 7 Release Notes Version 7 1 6e e Size and position of the Study Navigator dialog are remembered now 7705 e Abstract tags are shown in the DICOM information window 7624 e Issue with View all series phases side by side was fixed 8008 e Issue with distorted snapshots when exporting via clipboard was fixed 7755 e Issues with session links on Mac OS were fixed 7656 7745 RIS PACS Administrator e The logging and auditing functionality was enhanced It provides more detailed status information for support cases and facilitates better auditing of system use e Real time integration with LDAP Active Directory was added It offers a more streamlined user management when integrating V
17. art a job that has failed 7431 In Study Browser when searching for Institution Name it is possible to see a list of existing Institution Names in system 7867 RIS PACS Administrator Improvements to Linking and Protocol Editing 7841 8166 8196 8227 8283 Storage Commitment for external archiving In addition to responding to Storage Commit Requests the Visage system can now request storage commitment from external archive after sending DICOM images 4161 The auto router has been extended so that it is possible to DICOM forward images only after they were archived in Visage Another new option allows for automatic resending of images to a remote DICOM server after a QA operation has been performed Both features as well as the above mentioned Storage Commit Request feature allow for more flexible integration scenarios with offsite or deep archive architectures Visage desktop integration In addition to the existing integration methods vscontrol exe and the http launcher visage can now also be called via a custom protocol handler visage lt command line gt The protocol handler is also supported by Visage Ease allowing for App To App integration on the iPad iPhone Details are described in the Visage OEM Integration Interface Manual vscontrol manual It is now possible to customize the message shown on client launch in case an auto update is available or is required 8100 For each Image that cannot be inserted in
18. ate specification for the intended use Please contact Visage Imaging for details Appropriate environment conditions must be ensured including power supply cooling etc Copyright Visage Imaging GmbH 29 30 V68 00 Feb 2015 Visage 7 Release Notes Version 7 1 6e 5 Regulatory Information Manufacturer Address Visage Imaging GmbH Lepsiusstrake 70 12163 Berlin Germany www visageimaging com US Distributor Visage Imaging Inc www visageimaging com Safety Contact Safety officer for medical products Phone 49 30 700968 30 Fax 49 30 700968 11 Email support visageimaging com Support Contact Phone 49 30 700968 30 Email support visageimaging com Product Lifetime The product lifetime of Visage 7 is regulated to 2 years after the product is discontinued i e two years after the release date of the successor version of the product Support is guaranteed only within the product lifetime 1275 This software is CE compliant and is defined as a class Ila medical device in accordance with Medical Devices Directive 93 42 EEC Caution US federal law restricts the herein described devices to sale by or on the order of a physician Some of the specifications described herein may not be currently available in all countries All product names and company names are trademarks or registered trademarks of the corresponding companies Information in this manual may be subject to changes without prior a
19. bile backend component 11317 11334 11324 11360 11316 7 1 5d Technologist e CDs with anonymized patient data are labeled with a configurable standard text 10694 e Each item in the configuration of CD labels can have an attribute format This is particularly useful to format DateTime information due to individual requirements 10691 e Astudy s time of day can be changed via manual QA 10260 e Number of images per study is displayed in Study Browser Study Navigator and Quality Assurance Screen 5859 e Snapshots of reports in the Export Tab are independent of the printer settings 10702 e Screenshot saved as DICOM gets tag SliceLocation based on the original image data 10402 RIS PACS Administrator e The backend supports Windows Server 2012 R2 8701 11123 e The render server supports openSUSE 13 1 11884 7 1 5e e Visage 7 administration interface supports Internet Explorer 11 10707 e User specific customization of system protocols 10570 HMS 10603 10170 Show Layout Hide Layout Edit Layout Make default Layout oriented aspects of a protocol i e order visibility and default choice can be customized and saved as a user preference The customization is expressed and saved as a modification of the original protocol If the original protocol Reset Layout Preferences is changed the customization can still be applied on top of it Save Layout Preferences Copyright Visage Imaging GmbH 1
20. c Improved handling of manually selected window level settings Manual adjustments of window level are synchronized into all viewers displaying the same data and can be permanently stored as DICOM presentation states 10700 Better automatic window level if WindowLevel tag is missing in 8 bit data Barium Swallow 11815 7 1 6a Better initial window level for GE dose reports 11810 7 1 6a Usability improvements for user specific customization of system protocols 11260 11292 Snapshot of statistics tool card can be limited to selected rows 11227 Fixed issue with inverse thumbnails in conjunction with presentation states 12027 7 1 6c Fixed some issues in behavior of study navigator window 12104 12107 7 1 6c DICOM structured reports can be loaded and displayed even if the containing study has no image data 12184 7 1 6c Undesired zoom behavior upon drag and drop in certain linked viewer configurations 11813 7 1 6a Improvements of the tabular representation of lesions in a report 11761 12260 Fixed possible crash in HxVisagelmportTab showEvent 11809 7 1 6a Fixed potential client crash on auto logoff 11903 7 1 6b Fixed potential crash in lesion tool card after unloading studies 11807 7 1 6a Fixed potential crash in report dialogs after changing monitor configuration 11804 7 1 6a Fixed potential crash on startup Mac OS X 11937 7 1 6b The Structures tool card is available for
21. ctional integration to the Epic EHR and secure single sign on for internal and external users 10557 10796 11337 11465 11697 11787 11788 7 1 6b 12052 12054 12055 12058 12078 12267 7 1 6c A new mode allows using multiple hanging protocols Each protocol defines the hanging of one or more studies on one or more monitors 10841 11820 11823 12015 12019 7 1 6b 12031 1037 12198 12218 7 1 6c New concept Additional Relevant Priors While a small number of prior studies is hung automatically further relevant prior studies are visible in the thumbnail section and can easily be hung by drag and drop 11970 7 1 6b 12066 12041 12172 12271 12272 7 1 6c Improved strategy for restricting the number of automatically loaded prior studies The global maximum can be overridden by individual matching rules with a higher maximum 12090 12120 7 1 6c It is now possible to browse through images from multiple studies in the same viewer This is in particular useful for current prior comparison in mammography reading 9708 11662 11865 7 1 6b 12076 12084 12085 12125 7 1 6c 12196 12243 12310 7 1 6d The Quadrant Navigation tool has been improved in various ways For example image cropping is now available in the overview state and viewers can be excluded from quadrant navigation via the hanging protocol 11222 11663 12010 12020 11798 11873 7 1 6b 12086 12036 12202 7 1 6c 12
22. d LAO RAO for positioning a C arm in the corresponding orientation 12287 7 1 6d e Several additional DICOM tags of the original images are now passed on to key views 12377 7 1 6d e Usability enhancements for creating arrow annotations without text 12181 7 1 6d e Visibility of orientation cube in key views is now consistent with visibility in the viewer 10550 e Enhancements in the support of displays with high color depth like the BARCO Coronis Uniti 12MP display 12319 7 1 6d e User defined order of columns in Study Navigator persists after client restart 12212 7 1 6d e Added workaround hint to monitor configuration dialog for having the View tab on multiple monitors under Mac OS 10 9 and later 12397 7 1 6d e Close Session can now be triggered via keyboard shortcut 12213 7 1 6d e Fixed issue with initial image assignment to viewers in a tile group 12376 7 1 6d e Fixed issue with overall response classification in lesion workflow 12334 7 1 6d e Fixed issues with automatic initial selection of window level 12369 12391 7 1 6d e Fixed issue with showing hidden layout via user protocol customization 12311 7 1 6d e Enhanced handling of color coding of current and prior studies in inconsistent data situations 12598 7 1 6d e Fixed issues with display of reports for studies performed on the same day 12599 7 1 6d e Fixed issue with display of images per series in the Study Br
23. e under certain circumstances Saving the session will enable the corresponding menu entry 4073 e Saving PNG images on a full medium e g USB stick does not work Zero length image files are created and the user will not be notified Please save on medium with enough space 4077 e Edit tool card clearing the voxels of an object does not work while these voxels are selected in the viewer To work around this issue first press the clear button in the tool card then select clear object from the object context menu 4135 e In order to calculate SUVs for Philips PET data the DICOM images must contain Philips private DICOM tags to enable converting the pixel data given in Counts unit CNTS Either one of the tags 7053 1000 SUV Scale Factor or 7053 1009 Activity Concentration Scale Factor must be present Note if only SUV Scale Factor is present but not all of the following tags 0010 1030 Patient s Weight 0018 1075 Radionuclide HalfLife 0018 1074 Radionuclide Total Dose 0018 1072 Radiopharmaceutical Start Time 0008 0031 SeriesTime the activity concentration in a voxel cannot be determined In this case the user may only switch between display of the pixel data values Counts and SUV per body weight Philips g ml which is computed by applying the SUV scale factor to the pixel data value 4349 e If an external program triggers severa
24. eld is configurable 11758 7 1 6a Messages with non standard CON segment are accepted 11755 7 1 6b Display of report date fixed 11767 7 1 6b Study changes are applied to all studies with identical accession number 11839 7 1 6b O 0 Oo O OD OD Oo O O O O O O Copyright Visage Imaging GmbH 7 30 V68 00 Feb 2015 Visage 7 Release Notes Version 7 1 6e O O O O oO O Formatting issues in reports fixed 11841 7 1 6b Logging Auditing can be configured 11945 7 1 6b Performance improved 11944 11982 7 1 6b HL7 interface specification updated 11365 7 1 6b Reporting status is correctly displayed even if HL7 report comes in before images 12187 7 1 6d HL7 fields OBR 32 33 and 34 can be used for report display 12577 7 1 6d Messages containing are accepted by replacing with 12607 7 1 6d e Enhanced support for integration with third party systems O O O O O O Web launcher supports HTTPS access via Firefox Safari and Chrome 7574 Web link mode in client installer added _WL syntax 11938 7 1 6b Support for CCOW integration using Vergence COM component 11992 7 1 6c Enhancements in tray app to support situations where multiple Windows sessions are active Fast User Switch 11795 7 1 6b Changes in vscontrol weblaunch on MacOS X 11875 7 1 6b Web launcher is prevented from self termination under certain circumstances on next call after
25. ements for drag amp drop and viewer linking 6070 o Drag amp drop between 2D viewers not only swaps data sets but also linking groups i e linking is kept with the data o Linkingis preserved upon drag amp drop from thumbnail section to viewer if affected viewers are not in any translation rotation or camera linking group o Unloading a viewer by drag amp drop leaves linking unchanged e Scope of Automatically link viewers tool is restricted to unlinked slice viewers in the current layout 10592 e Improved heuristics for automatic viewer linking 10472 e Improved default value for property Maximum Slice Tilt for Automatic Grouping 10479 e Consistency of behavior after dragging data into a viewer in full screen mode has been improved 10674 e Save Modified Images tool applies window level changes to the images in memory to make them immediately effective in the current session Adjusted window level settings are now preserved when prior studies are added to the current session 7159 e For Reports Documents created in PACS Export tab Allow to review previous versions of a report in the Export Tab 10683 Zi Options Refresh 2014 Jan 28 13 45 13 v3 Previous Versions 2014 Jan 28 13 44 27 v2 2014 Jan 28 13 43 a 1 e Fixed issue with updating automatically generated data in PACS reports 10968 e Fixed issue with dragging a vessel line segment to insert a new vessel point 10555 e Fixed is
26. format and can be stored in Visage or a third party archive If a prior exam with marked lesions exists convenient single click navigation through those markings is available and automatic linked scrolling to the corresponding locations in the current exam e Drag and drop of image sets from viewer to viewer by grabbing any viewer text to swap the contents of those two viewers When mouse is over viewer text a drag or hand cursor is displayed Drag and drop from viewer onto thumbnail section unloads the viewer Data sets are swapped if possible e Improved user interface in thumbnail section Thumbnails are now grouped by study e New tool Edge Enhancement filter Enhancement intensity is adjustable interactively 5276 e General Improvements for viewing XA images 8096 8214 e Improvement to the batching tool it is now possible to create stacked or rotational batches cines from CPR views e Multiple improvements in Neurology option perfusion result DICOM images are now more interoperable with third party systems 4326 center line editing is easier 6943 result images can now be saved using batching tool 8077 e User interface for generation of de identified studies and assignment of teaching labels 8475 The Study Browser provides a context menu item De identification and Teaching Files that allows to copy one or more studies and thereby to eliminate personal DICOM information that would allow to identif
27. his allows stepping through the most recent sessions of a series of studies using the Next Study from Study Browser button in the View Screen This is useful for presenting a series of cases Image files in TIFF format in addition to PDF documents and image files in JPEG PNG and BMP format can be attached to a study 9006 New tool to perform automatic window level computation based on a 2D region of interest 8957 Measurements with tool Angle Two Lines can be shown on all slices of a stack 8486 This can be useful if the two axes that define the angle are optimally defined on two different Slices Tool Magnifying Glass size of magnified region is always adapted to size of current viewer 9430 Re added orientation letters in CPR viewer 9923 7 1 3a Backend provides URLs linking to studies for inclusion in reports 9583 Following such a web link embedded into a report will open the respective study in the Visage client In an integrated RIS PACS workflow the new tool View Reports RIS allows to access reports in ProMedicus RIS directly from the View screen 9581 Information about lossy compression can be displayed as viewer text 8908 Improved handling of different W L values in 3D MRI studies 10047 7 1 3c Added on the fly conversion for Digital Breast Tomography DBT images 9802 7 1 3a Fixed issue on viewer unloading by drag n drop 9908 7 1 3a Copyright Visage Imagi
28. in prefetching on the backend related to undefined study instance UID 11596 e Issue with server username during GPO rollout with MSI installer fixed 11731 e Series and image level C FIND and C MOVE fixed on online systems 11817 7 1 6a e Issue with modality work list configuration fixed 11811 7 1 6b e Improved strategy for bandwidth controlled network transfer 11975 7 1 6b e Special auto logoff timeout for external sessions implemented 12053 7 1 6c e Fixed issue with installing a 7 1 6 client over a 7 1 4 client while the web launcher is running 12044 7 1 6c e DICOM images with Jpeg2000 encoding are accepted via CD import and via DICOM connections 10704 12521 7 1 6d e Authentication via Active Directory AD Priorities can be assigned to Visage relevant AD roles in order to influence which role a user is assigned to if he she is in multiple mapped AD groups 11843 7 1 6d e Certain vendor specific private DICOM tags that are relevant for further processing in Visage are kept during de identified Media Export 12399 7 1 6d e Several improvements of the administration webpages 12378 12381 12458 7 1 6d e Various improvements to overall backend stability 12117 12403 12412 12433 12481 12625 7 1 6d e Improvements to handle inconsistent DICOM data 11853 12534 7 1 6d e Increased flexibility in configuring rejection of double insertion of images in StorageManager 12560 7 1 6d
29. isage with other clinical information systems and into existing IT environments e Support for prefetching from multiple DICOM nodes was added e Prefetch timing for future appointments was optimized Now prior studies are prefetched only a few days nights before the appointment The number of days can be configured on the admin pages e Aweb services API for user management was introduced It is described in a separate design document Visage 7 WS User Management e When creating editing or deleting users on the admin pages the changes may be propagated to all partner systems e A button for resetting the synchronization of VisageLocal among partner systems was added to the admin pages 7485 e The on the fly volume conversion was accelerated by generating the volumes on the backend server in a separate converter process e For images imported via the Filelnterface the volume conversion is triggered automatically 6429 e Issues with the Pseudo Archive feature were fixed 7592 7700 e Issues with vscontrol when using user names containing spaces or IWA fixed 7697 7735 e Issue with HL7 order messages without study description fixed 7606 e Issue with auto router in conjunction with manual QA fixed 7615 e Issue with volume conversion when prefetching large DICOM files fixed 7740 e Issue with space manager due to database constraint violation fixed 7587 e Issue with installing backend as domain
30. l DICOM query retrieve operations subsequently via vscontrol and the first one is not yet finished all operations except for the first will be silently ignored 4323 Visage 7 Server e Please make sure that for distributed QA operation the patient matching strategy is configured exactly the same on all partner servers e For the Expert Reading Client option custom protocols can be defined These protocols can use DICOM tags that are not part of the standard protocols for sorting When updating from an existing installation with custom protocols the tool TrimHangingProtocolDB can be run in order to remove DICOM tags from the database that are not used by any protocol this increases the input performance If you want to add a custom protocol that uses one of these DICOM tags to a freshly set up server please contact customer support 5916 5256 Copyright Visage Imaging GmbH 28 30 V68 00 Feb 2015 Visage 7 Release Notes Version 7 1 6e 4 Important Server Installation Notes The Visage server side backend and render server software must be installed and configured only by service personnel authorized by Visage Imaging e The indications for use and other important notes are described in the section Intended Use in the user manual e Donot install any third party software on the servers or otherwise manipulate the system e For proper operation Visage must be installed on server and client hardware with adequ
31. n Improved tab navigation in Study Browser 8898 ECG data encoded in DICOM tag group 50xx can be displayed as an overlay curve 9219 Copyright Visage Imaging GmbH 17 30 V68 00 Feb 2015 Visage 7 Release Notes Version 7 1 6e Playback of pre and post stress cardiac ultrasound cine clips can be synchronized based on ECG information 9007 9216 A sequence of single images and clips e g from ultrasound examinations can be shown in one consistent tiled layout and can thus be read in chronological order 9036 9392 Tiles showing clips are labeled with a play icon in the upper left corner of the viewer Cine animation can be started stopped by clicking this icon Improved stability for browsing in tiled layouts 9888 9995 7 1 3c Cine tool card provides a new slider Speed for adapting the speed of cine animations 9007 9406 Improved responsiveness during loading of studies with large multiframe data sets 8360 8717 9122 9340 Improved loading performance of DICOM data with large LUT sequences 9560 Display of progress bar during study loading is configurable and depends on estimated loading time 9266 Improved handling of DICOM images with display shutters 9241 Viewer context menu can be opened via tool button in Tool Palette 9160 Window Level presets can be accessed via tool button in Tool Palette 9121 Next Study from Study Browser button can load recent session 8930 T
32. n 10126 Search mask in study browser window allows selection of multiple study labels 9471 Improved selection of initial window level for bad DICOM parameters 10282 7 1 4b Fixed issue with time density graph not showing up for breast MRI series 10393 7 1 4a Fixed issue with degenerate values in MRI perfusion series 10554 7 1 4b Fixed issues with docked lesion tool card 9974 9975 7 1 4a Fixed issue with voice memos in thumbnail section 10501 7 1 4b Improved stability of thin client and server Fixed issues in server side rendering session start up DICOM job list magnifying glass fusion mode CR images with empty DICOM tag NumberOfFrames partnering and auto prior rules 9309 10263 10279 10295 10355 10380 10440 10444 10449 7 1 4a 10457 10458 10468 10498 10544 7 1 4b 10616 7 1 4c 10625 7 1 4d Technologist Orientation cube is included in output images of 3D rotational batching 10208 De identification of patient data in media export assigns the same patient ID to studies of one patient and works on export to server and disk producer stations 10278 10309 PDF files may be attached to MR studies containing PR series 9976 Fixed issue when pasting snapshots into external applications 10561 7 1 4b Improved handling of images in Word documents 10742 7 1 4d Writing of sessions is more robust 10067 10078 Fixed issues in session list 10358 10390 7 1
33. nd ROls 8075 PDF documents and image files in JPEG PNG and BMP format can be attached to a study Several issues were fixed for improved stability and performance 8086 8143 8148 8258 Technologist Viewer text is no longer saved in DICOM snapshots New option Anonymize on DICOM CD import Standard Patient demographics and study information can be replaced or deleted In addition the following DICOM tags now anonymized 7791 7829 ReferringPhysicianName ReferringPhysicianAddress ReferringPhysicianTelephoneNumbers InstitutionAddress StationName PatientBirthName OtherPatientiDs OtherPatientNames PatientMotherBirthName PatientTelephoneNumbers InstitutionalDepartmentName PhysiciansOfRecord PerformingPhysicianName OperatorsName RequestingPhysician RequestingService IssuerOfPatientID NameOfPhysiciansReadingStudy Oo oo 0C 000000000000 0 Copyright Visage Imaging GmbH 22 30 V68 00 Feb 2015 Visage 7 Release Notes Version 7 1 6e Quick search in DICOM tags dialog active from 3 characters with highlighting and navigation Quick search in tool palette dialog active from 3 characters with highlighting and navigation Improved DICOM Job Dialog with additional functionality User can now monitor transfers from client to server DICOM send jobs DICOM retrieve jobs and DICOM print jobs User can now refresh status cancel a running job delete a job that hasn t run yet and rest
34. network access of the Visage Client application This may severely impact Visage Client performance 5436 e Though deprecated the Visage Client does run on client computers which do not support SSE2 instructions but only without local rendering Some functions that require local rendering e g the magnifying glass do not work 6382 e When using the mouse wheel or the PgUp PgDn keys with thick slices in an orthogonal MPR view the center of the thick slice is always adjusted to lie on the center of the closest thin slice This can lead to a different step size than the selected slice thickness 6291 e Vessel analysis for multiple DICOM studies should not be performed in a single working session during vessel analysis the user should avoid switching layouts in the protocol Furthermore vessel tracing should only be applied to 3D volumetric Image Sets 5466 5467 5469 e When viewing two images in fusion mode the 3D bounding box of the overlay image cannot be displayed in the MPR and 3D viewers 479 e Remove tools amp Fusion When applying Remove Inside to primary and overlay in fusion mode and increasing the slice thickness in the MPR viewers the removed overlay material is still shown in the MPR viewers 963 e The Visage Client currently does not support all characters for user names that can be set in the Visage backend In particular the characters and must not be used In general the characters a z A Z
35. ng GmbH 18 30 V68 00 Feb 2015 Visage 7 Release Notes Version 7 1 6e Fixed issue with viewer layout after minimizing maximizing on multi monitor configuration 9990 7 1 3a Fixed issue with protocol defined values of attribute FusionWeight 9948 7 1 3a Fixed issue with loading of studies with multiple lesion SRs 10000 7 1 3c Fixed issue with study navigator not showing studies without images 10062 7 1 3c Improved robustness of session loading 10064 7 1 3c 9998 7 1 3d Improved stability of server component 10167 10168 7 1 3d Fixed issue with automatic reset of MPR viewers to thin slice mode upon activation of certain tools 9980 10015 7 1 3e Improved robustness of measurement and annotation tools 10232 10257 7 1 3e Technologist The Import Tab initially displays all studies collapsed if 8 or more studies are imported at once 9004 Archiving of not yet archived studies can be scheduled and unscheduled via context menu in the Study Browser 8912 New and unified user interface for de identification in different contexts import export teaching files 8900 Recording functionality of the Cine tool card allows image generation in reverse order 9483 Batch reformatting can be configured to save current user defined window level as default for the resulting image stack 8578 Improved performance of DICOMDIR generation during media export 8246 Media export can
36. nnouncement Copyright Visage Imaging GmbH 30 30 V68 00 Feb 2015
37. owser 12147 12418 7 1 6d e Fixed issue with display of study description in Reset Dictation dialog 12266 7 1 6d e Fixed issues with associated patient IDs 12298 7 1 6d e Fixed issue with interference between the Triangulation tool and the Link Scrolling tool 12450 7 1 6d e Fixed issue with the Triangulation tool if not all data sets cover the current point of interest 12451 7 1 6d e Fixed issue with client freeze during session saving 11704 7 1 6d Copyright Visage Imaging GmbH 6 30 V68 00 Feb 2015 Visage 7 Release Notes Version 7 1 6e Technologist It is now possible to select an image series or study in the Study Browser or View screen and open it in the Quality Assurance screen 11942 7 1 6b 12013 12232 7 1 6c Number Date and Time of DICOM series and images can be edited via the Quality Assurance screen 11789 7 1 6b Choice of font sizes for Image Content QA has been extended to improve usability on high resolution images e g for mammography 12170 7 1 6c The Delete button has been removed from the Study Browser Deletion of studies is only possible through the Quality Assurance screen 11949 7 1 6b Deletion of DICOM data in external archive upon manual deletion of DICOM data in Visage can be suppressed now if explicitly requested 11771 7 1 6b Improved alignment when printing mammography images in true size on small film sheets 12203 7 1 6c
38. rate host The server can be a named instance 8889 9090 9300 Backend supports SQL Server 2012 8700 Various improvements in the audit trail mechanism 8905 Enhanced auto routing by new rule type all but 10048 7 1 3c Extended external toolbar mechanism 9148 9292 In addition to the previous options triggered actions can be querying a URL HTTP GET ora call to the ProMedicus RIS via PMContext Actions that could previously be triggered only by pressing buttons in toolbars can now also be triggered when the client is started when a study is loaded or when a study is closed Improved integration with ProMedicus RIS Support for extended web interface of ProMedicus Coral RIS 9814 9958 9971 7 1 3a New command UNLOAD_ DATA for PMContext 10074 7 1 3c When a study is loaded a STUDY_LOADED event is sent to the RIS 10087 7 1 3c Added support for Internet Explorer 10 to Visage 7 administration interface 9297 7 1 3a Added support for storing Agfa DICOM CC objects 10178 7 1 3d Faster processing of configuration changes on the User Management page of the Visage 7 administration interface 9451 Improved robustness and performance of QA operations 9682 9898 7 1 3a Improved loading of studies on OEM calls when the system is partnered and not all requested studies are available 9915 7 1 3a Improved disc space management for the case of multiple image root folders 8909 Impro
39. s 11288 7 1 5d Added support for HL7 version 2 2 11296 7 1 5d Improved handling of additional user levels during backend updates 11281 7 1 5d Extended logging of events from mobile client 11321 7 1 5d Referring Physician Robustness improvement of Media Viewer 11272 7 1 5d Version 7 1 4 Radiologist New tool Next Thick Projection Mode with keyboard shortcut Shift T for switching the projection mode of thick slices between maximum intensity MIP minimum intensity MinIP and average intensity AvIP 10022 New tool Configure Tool Palette opens the configuration dialog of the tool palette 10019 Tool Measure Lesion 2 Diameters snaps to perpendicular configuration 10194 Copyright Visage Imaging GmbH 15 30 V68 00 Feb 2015 Visage 7 Release Notes Version 7 1 6e Value for threshold adjustment of lesion segmentation is no longer shown when defining next lesion 10192 Computed statistics on lesions in export tab are updated when deleting a lesion 10269 Viewers with activated cine auto trigger start playing automatically if image set is switched by drag amp drop or if next previous image set is selected 10299 Improved handling of protocol defined viewer orientations 10446 10455 10456 7 1 4b When using tool Automatically Link Viewers slightly tilted image series may be grouped together by defining a tolerance for the slice orientatio
40. s in the Study Browser support Issuer of Patient ID 10688 e Fixed issue with querying studies in date time ranges spanning more than one day 6613 11887 7 1 5e e The thin client for Mac OS X is now provided as a 64 bit application 8964 e The thin client for Mac OS X now also has buttons for fast switching between the different screens i e Study Browser View Export and Quality Assurance 5571 Study Browser Export Quality Assurance e Improved crosshair visibility on gray scale monitors 10622 e Every distance or angle measurement can be displayed on all slices of a stack 10155 e Length measurements in Lumen view are reflected by position references in the corresponding CPR view 10569 Copyright Visage Imaging GmbH 11 30 V68 00 Feb 2015 Visage 7 Release Notes Version 7 1 6e e Status and availability of the Subtract Baseline Phase toggle are specific to the active viewer 10552 e Subtraction mode is taken into account by Auto Window Level in ROI tool 10553 e Automatic viewer linking does not switch off subtraction mode 5091 e New tool Magnifying Glasses allows simultaneous magnification in multiple viewers 10115 Lal EJ rm ch e Thumbnails for PDF attachments are labeled with the respective series description 10114 10298 e The Link Scrolling tool enables linking of multiple MPR groups with each other 10621 11266 7 1 5d e Improv
41. sue with rendering DICOM image data with non zero intercept 10523 e Fixed issue with window level changes in a layout with active viewer dependency 10507 Copyright Visage Imaging GmbH 12 30 V68 00 Feb 2015 Visage 7 Release Notes Version 7 1 6e e Fixed issue with display of scout lines in 2D viewers 11182 e Improved thin client stability in various aspects 10782 10477 10780 10238 10979 10964 11242 7 1 5b 11313 11226 7 1 5d 11879 11882 11883 11886 11892 11905 11908 11909 11911 11912 11914 11956 7 1 5e e Fixed client startup failure on certain monitor configurations 11220 7 1 5a e Fixed issue with crosshair rotation in MPR viewers 11239 7 1 5b e Fixed issue with rotation in the Lumen viewer 11240 7 1 5b e Fixed issue with Permanent Text Label tool 11257 7 1 5c e Fixed issue with non functional Cancel button in de identification dialog of media export 11231 7 1 5c e Fixed issue with pan zoom adaptation after dragging and dropping another volume into a viewer 11235 7 1 5c e Fixed issue with enhanced DICOM sequences in brain perfusion data 11282 7 1 5d e Fixed issue with initialization of zoom linked viewers 11273 7 1 5d e Fixed issues with updating values in Statistics tool card 11765 11890 11910 7 1 5e e Fixed issue with initial zoom level after drag and drop of US images 11888 7 1 5e e Improved handling of W L values in mo
42. tion 12207 7 1 6c Copyright Visage Imaging GmbH 8 30 V68 00 Feb 2015 Visage 7 Release Notes Version 7 1 6e o DICOM Structured Report should remain visible after merging two studies 12071 7 1 6c e Improved behavior of zoom linking group Linking is always active for viewers showing the same data Linking toggle activates linking between viewers showing different data 10425 12109 12221 12233 12240 7 1 6c 12178 7 1 6d e Hanging protocols can specify image orientation and alignment per ImageSet This will overrule respective settings of the viewer 11290 11972 7 1 6b 12056 7 1 6c e Hanging protocols can now check aspect ratio and number of monitors for every single layout This allows writing a single hanging protocol per use case that applies to all monitor configurations The standard set of hanging protocols has been adapted respectively 10792 11544 11822 7 1 6a e For automatic viewers a minimum number can now be specified in the hanging protocol 11855 7 1 6b e Improved audit trails for outgoing HL7 messages and delete protection 10881 11419 e Maximum number of prefetched studies considers existing studies 10958 e Backend monitoring includes drives that do not have a drive letter assigned 11219 e Per user customization of layouts has its own user level permission 11253 e Deletion of session from delete protected patient is prevented 11509 e Fixed issue
43. to the Visage system and is moved to the _StoreFailed directory a text file is created that states the reason for the insertion failure 8185 Improved system logging 8158 8159 8162 8163 8164 8165 8179 8180 8243 Reliability and performance of the database access in the backend have been significantly improved Usability of the TraceLog tool has been improved with a filter function for user levels The default user level configuration has been revised QA It is possible to edit the date of a study 6859 Institution name can be edited during CD import as well as during QA 7791 7792 Referring Physician Patient Search Screen Referrer Portal now has search presets as in Study Browser 7699 Number of search results in the Patient Search screen can now be limited 7425 Copyright Visage Imaging GmbH 23 30 V68 00 Feb 2015 Visage 7 Release Notes Version 7 1 6e Version 7 1 0 The Visage Client comes with a new integrated update mechanism and natively supports 64 bit Windows systems The Visage Backend provides improved logging and auditing functionality and supports user management via Active Directory and LDAP The new context aware online help introduced in 7 0 11 is available in German in addition to English Radiologist Native support for 64 bit Windows systems was added to the Visage Client This allows the client side memory management to allocate more memory for caching when reading
44. user with local admin rights fixed 7618 e Several issues with QA operations were fixed 7634 7805 8015 8033 Referring Physician e A property for defining the default location in the Patient Search window was added 7569 e Issues with loading images from partner systems were fixed The Location field is initialized correctly and the report viewer does not disappear 7701 7702 Copyright Visage Imaging GmbH 25 30 V68 00 Feb 2015 Visage 7 Release Notes Version 7 1 6e 2 Supported Client Operating Systems Visage 7 is available for the most recent technology of the following client operating systems Windows e Windows 8 e Windows 7 e Windows Vista e Windows XP Mac OS X e Mac OS 10 9 Mavericks e Mac OS 10 8 Mountain Lion e Mac OS 10 7 Lion Copyright Visage Imaging GmbH 26 30 V68 00 Feb 2015 Visage 7 Release Notes Version 7 1 6e 3 Restrictions and Known Issues Visage 7 Client e The system operator has to ensure that the local laws and regulatory standards concerning data security and data confidentiality especially for the health care sector are fulfilled Examples are ASTME 1986 ASTME 1987 EN 14484 EN 14485 and ISO 22857 This especially applies when transferring data in networks without using secure data encryption or secure VPN software e Please make sure to not run any security software on the client machine that tries to monitor the
45. ved backend status page 8904 Improved import of Enhanced DICOM data 9391 Improved robustness of DICOM import 8987 9052 9187 9293 9363 9375 9562 10228 10262 7 1 3e Improved handling of password expiration 8899 9183 Upon login the user will be asked to change her password if the password is about to expire soon If the password has already expired login is only possible after changing the password Fixed issue in loading of studies containing images and scanned documents 10018 7 1 3b Fixed issue with hanging order of current studies on OEM calls 10149 7 1 3d 10261 7 1 3e Fixed issue with partnering when using external address mapping rules 10154 7 1 3d Referring Physician Update of client installer for Mac OS X 9803 The installer will always install the auto launch service Besides the installer the thin client is still provided in a DMG for simple drag and drop installation without the auto launch service Copyright Visage Imaging GmbH 20 30 V68 00 Feb 2015 Visage 7 Release Notes Version 7 1 6e e Fixed display of search mask on patient search screen if RIS is configured to show only signed reports 9962 7 1 3a Version 7 1 2 Radiologist e Significantly enhanced workflow for oncology follow up reporting Marked lesions in current and one or more prior exams are displayed and can be edited in the new Lesion tool card Markings are now saved in DICOM SR
46. y the imaged person A teaching label can then be Copyright Visage Imaging GmbH 21 30 V68 00 Feb 2015 Visage 7 Release Notes Version 7 1 6e assigned to the copied studies Both steps are optional If the studies are not copied the label is assigned to the original studies This functionality allows to easily preparing a set of studies for demonstration and teaching purposes by copying and de identifying studies from the clinical routine Different teaching labels allow handling of multiple sets of such studies for different teaching opportunities Automated loading of relevant prior studies Upon initiation of a new session Visage7 can automatically load relevant prior studies of the patient the primarily loaded study belongs to The selection of relevant studies can be done based on simple fixed criteria or more complex configurable rules The feature can be configured system wide and for individual users Using the oblique viewing functionality in Visage the current viewing angle is now shown 8065 Size of color bar adjusts if viewer is too small 7160 Viewing of 3D volumes with gantry tilt improved 8085 3D Crosshair now indicates orientation of MPR planes 7761 Support for Digital Breast Tomography DBT SOP class It is now possible to annotate measured values The actual measurement s are represented by a place holder to which you can add custom text Diameter statistics are now shown for 2D freeha

Download Pdf Manuals

image

Related Search

Related Contents

Manual de instalación ecoTEC plus alta potencia Manual  Samsung SCX-5312F Manual de Usuario  600 TV Lignes Super Haute Résolution Couleur  machineries sémiotiques et médiations techniques  eBOX621-801 A1 User Manual  キャメロット X4 取扱説明書  NTFS Undelete User Manual  コンフィギュレータソフトウェア (形式:RZMSCFG) 取扱説明書 - M  eSpring® Carbon WTS Owner`s Manual  1 - Back  