SICOM3170 Series Managed Traffic Ethernet Switch
Contents
1. DB9F plug console cable which connect the console port with the 9 pin serial port at the computer using CLI to configure sicom3170 Table 3 console port pin definition RJ 45 8 Pin Jack Signal Name Signal Description Golden finger for power connection SICOM3170 has golden finger to connect with plug 12VDC or 24VDC power supply is offered by the cabinet backplane Table 4 Golden finger Description Golden finger Signal Name Signal Description 22 Pin plug INPUT 24 VDC INPUT Chassis Ground KYLAND PWR PWR CO ABCDEFHIKLMNPRSTUVWXYZ Figure 6 Golden finger for power connection 6 LED indicators The LED indicators in the front panel of SICOM3170 can indicate system operation status and port status in order to find and settle faults Table 5 shows the meanings of LEDs in the front panel Table 5 LED indicators system status LEDs Blinking Switch operates normally RUN Green Switch does not operate or operate abnormally Power is connected and operates normally ON PWR Green Power is not connected or OFF Gigabit fiber port status LEDs G1 and G2 operates abnormally Effective network connection in the port LINK ACT Blinking Network activities in the port Green No effective network connection Off in the port Effective network connection in the port rA KYLAND No effective network connection in the port Off Ethernet RJ45 po
2. FE7 2 Are you sure of settings GE8 Enable w Off w GE1 GE2 Disable Y 1001 Full v Off v Disable v 100M Full w Off v click port configuration set status of GE1 GE2 enable the Auto click Apply see picture below 14 2 FE2 FE3 FE4 FES FE6 FE7 GES GE1 GE2 Enable Enable Enable Enable Enable Enable Enable Enable Enable Enable v Enable w Enable vw Enable Y Enable vw Enable w Enable v v Enable w Enable v Enable v Enable vw Enable w Enable vw Enable Enable v 5 4 MESE click OK see picture below MEL Buble v Bnable y rea erable vy lrei CIEN Fe mante Y inte y res Eraio al Eranio Fes ELEDE FE7 SES Enable w Enable w Enable vy Enable y Enable w Enable w Enable vy Enable Enable w 10M OM 100M DM OM OM 10M off off off off off off off off off lt lt ES EALA v y click save configuration and then 100M SFP module is available See picture below FEA fable y Babe w CLI Command Log in the device through Console or Telnet SWITCH gt en ANECA enter configuration mode SWITCH configure terminal enter port configuration mode SWITCH config inte
3. Password recovery The username cannot be changed you only need to recover the password while don t know the password Please login the device through console port or telnet input following command to recover the password under Config mode config web authentication password lt password gt lt password gt can be 1 32 numbers or alphabets For example if you want to change the password into 1234 please input web authentication password 1234 The main page is as Figure10 At the left of the page there is a management tree menu which includes the main menus of Device Status Basic Configurations Advanced Configurations Device Management Save Configurations Load Default Click each main menu to open its sub menu There are two function keys on the tree menu Collapse and Expand Click on expand to display the main menu and all sub menus Click on collapse to display the main menu and close all sub menus 11 Figure 10 Main page 10 CLI management Log in Command Line Interface through two ways CONSOLE Interface and Telnet CONSOLE Interface 1 Using the network cable one end is a RJ45 connector and the other is a serial port to connect the serial port from the PC with the CONSOLE interface on the SICOM3170 2 In the desktop of Windows click Start Program Accessories Communication Hyper Terminal Setting the parameters of the PC serial port as below Table
4. 6 Setting the parameters of the PC serial port Baud Rate 9600 O oms o 3 Open the hyper terminal and power on the device In the process of device startup print the device information on the hyper terminal page When the device startup complete press Enter key then you can see a prompt 12 KYLAND in the serial port default is SWITCH gt 4 When command prompt appears in CLI type enable to enter command line operation mode there will be a command prompt SWITCH SWITCH gt enable General users configuration mode SWITCH config terminal Authorized users configuration mode SWITCH config Global configuration mode SWITCH config ip address lt ip address gt mask lt mask gt IP address configuration SWITCH config ip gate lt ip address gt Gateway address configuration SWITCH Show interface IP address query SWITCH reboot Device reboot SWITCH load default Restore default configuration 5 Please check the detail in CLI Configuration Manual TELNET 1 Using cross over cable or straight through cable to connect a Ethernet port in the switch with the network card of PC through Ethernet 2 Type telnet 192 168 0 2 in Operation window in Windows system or MS DOS command prompt click apply 3 After the switch startup complete press Enter key Default is SWITCH gt 4 Please check the detail in CLI Configuration Man
5. D Enable Enable v FE3 Enable Enable 1001 Full Off FE4 Enable yv Enable v LOM Halt Off v FE5 Enable v LOM Half Off v FEB Enable v LOM Off w FE7 9 Enable v Off v y Are you sure of settings 7 GE8 Enable v GE1 GE2 Full v Full v Disable v Disable v 7 click save configuration and then SFP module with 1000M is available 2 CLI Command Log in the device through Console or Telnet SWITCH gt en enter configuration mode SWITCH configure terminal enter port configuration mode SWITCH config interface ethernet 9 10 set status of GE1 GE2 1000M _ full duplex auto disable SWITCH config if eth9 10 no auto negotiation SWITCH config if eth9 10 duplex SWITCH config if eth9 10 speed 1000m Do the same with Port 10 and go back to the main menu click save configration and then SFP module with 1000M is available SWITCH config if eth9 10 end SWITCH save 12 User Manual CD for User s Manual is attached PDF Format 17 KYLAND KYLAND For further information about Kyland please visit our website www kyland cn Address Chongxin Creative Building Shixing East Road 18 Shijingshan District Beijing China TEL 86 010 88798888 18
6. NTY 5 years 4 Panel Layout Figure 1 Front panel view 1 G1 Gigabit SFP slot G2 Gigabit SFP slot G2 LINK ACT LED P N G1 LINK ACT LED SS SY SY 10 11 12 13 14 AMYLAND RUN system operation status LED PWR power status LED CONSOLE Interface 10 100 1000Base T X RJ45 port ACT LED 1x10 100 1000Base T X RJ45 port 10 100 1000Base T X RJ45 port LINK LED 10 100Base T X RJ45 port SPEED LED 7x10 100Base T X RJ45 ports 10 100Base T X RJ45 port LINK ACT LED Figure 2 Rear panel view Handle 15 Golden finger for power connection 5 Ports Gigabit SFP slot SICOM3170 supports 2 X Gigabit SFP ports Ports ID G1 G2 optional 1000Base SX LX LH ZX LC connector KYLAND TX RX Figure 3 SFP slot Figure 4 1000BaseSX LX LH ZX port 10 100 1000Base T X RJ45 port SICOM3170 supports 1 X 10 100 1000Base T X RJ45 port Ports 1D 8 Figure 5 RJ45 8 Pin Jack Table 1 10 100 1000Base T X RJ45 port pin definition MDI MDI X RJ 45 8 Pin Jack Signal Name 7 TD3 OE LH 10 100Base T X RJ45 port SICOM3170 supports 7 10 100Base T X RJ45 ports Ports 1D 1 7 Table 2 10 100Base T X RJ45 port pin definition RJ 45 8 Pin MDI NIC port MDI X Switch port 6 KYLAND Signal Name Signal Name Tx Rx Tx Rx RS 232 10 pin RJ45 console port SICOM3170 s console port is a Shielded RJ45 modular jack The standard of serial ports is 3 wire RS232 supplying RJ45 plug
7. SICOM3170 Series Managed Traffic Ethernet Switch Quick Installation Manual oy KYLAND Technology Co Ltd First Edition Jul 2010 www kyland cn Industrializing the Ethernet Simplifying Industrial Communication P N 1 12 02 0034 0 KYLAND 1 Packing list The package list includes the following items SICOM3170 Managed Traffic Ethernet switch 1 RJ45 to DB9 Console port cable 1 Customer Service Guideline 1 Screw driver 1 Protective caps for RJ45 ports 9 Protective caps for SFP ports 2 Quick Installation Manual 1 CD for User s Manual 1 NOTE After unpacking please check the accessories and the appearance of the equipment if anything is missing or damaged please contact us 2 Product Overview SICOM3170 is an ultra low power consumption 7 2W managed traffic Ethernet switch specially designed by KYLAND Technology CO LTD for traffic control intelligent transport system Its high performance switch engine solid and sealed case over current overvoltage and EMC protection at power input terminal and excellent EMC protection of RJ45 port make SICOM3170 run well in harsh and dangerous industrial environments The SICOM3170 Traffic Signal Control switch is the first of a series of EZ Traffic Networks products from Kyland and a continuation of our Green Ethernet product line SICOM3170 is inserted into a rack through the rail slots SICOM3170 provides 2 uplink redundant Gigabit pluggable SFP slots in t
8. he front panel which can form Gigabit fiber redundant ring network with the recovery time less than 50ms KYLAND 1 10 100 1000Base T X RJ45 port and 7 10 100Base T X RJ45 ports Each of RJ45 port supports self adaptive function and MDI MDI X auto connection 3 Product Features Interface Gigabit SFP slots 2 Gigabit SFP slots for 100 1000Base SX LX LH ZX LC interface modules Gigabit copper port 1x10 100 1000Base T X self adaptive RJ45 port 100M copper ports 7x10 100Base T X self adaptive RJ45 ports CONSOLE interface RS232 RJ45 Standards IEEE 802 3 IEEE 802 3u IEEE 802 3x IEEE 802 3z IEEE 802 3ab IEEE 802 1d IEEE 802 1w IEEE 802 1p IEEE 802 1q store and forward switching mode Backplane switching capacity 9 6G MAC address table size 8K Cable Twisted pair 0 100m Multi mode fiber 1310nm 0 550m 1000Mbps Single mode fiber 1310nm 0 40km 1550nm 0 80km Power requirements Power input 24VDC 9 36VDC Power consumption lt 7 2W Physical characteristics AYLAND Case Aluminum case fanless Protection class IP40 Installation Inserted into a rack through rail slots Dimensions WxHxD 41 45mmx114mmx167 5mm The width of the front panel is 58mm and the depth of the handle is 27 5mm Weight 0 8kg Environmental Limits Operating Temperature 40 to 85 C 40 to 185 F Storage Temperature 40 to 85 C 40 to 185 F Ambient Relative Humidity 0 to 95 non condensing WARRA
9. rface ethernet 9 10 set status of GE1 GE2 100M 15 OM OOM OM LON 100M LOOM full duplex auto disable KYLAND SWITCH config if eth9 10 no auto negotiation SWITCH config if eth9 10 duplex SWITCH config if eth9 10 speed 100m Enable the Auto negotiation SWITCH config if eth9 10 auto negotiation Do the same with Port 10 and go back to the main menu click save configuration and then 100M SFP module is available SWITCH config if eth9 10 end SWITCH save NOTE 1 Gigabit SFP Module can be used as default the default status of the port is 1000M full duplex auto disable Configurations of switching back to Gigabit SFP module status 1 Web Interface Log in web interface click port configuration set status of GE1 GE2 1000M full duplex auto disable click Apply see picture below FE Enable v Enable v Enable vw Off y FE2 Enable v Enable y Enable y Off v FE3 Enable v Enable w Enable v Off y FE4 Enable y Enable Enable jv lon 3 Off y FES Enable v Enable v Enable v N Hal off FE6 Enable wv Enable Al Enable wl M 2 Off v FE7 Enable Y Enable Enable jw 10 7 Off y GE8 Enable vw Enable v Enable w LOM Off y GE1 Enable w Enable wv GE2 Enable v Enable vy Disable v 10001 v Full y click OK see picture below 16 KYLAN
10. rt status LEDs 1 7 Each RJ45 Ethernet port has two indicators a yellow lamp and a green lamp The yellow lamp indicates port rate and the green lamp indicates port connection state 100M working state On SPEED i e 100Base TX Yellow 10M working state Off i e 10Base T Effective network connection in On the port LINK ACT Blinking Network activities in the port Green No effective network connection Off in the port Installation Figure 7 Dimension drawing KYLAND Figure 8 Mounting on the rack Note 1 Rack for mounting 2 Power socket 3 Back panel 4 SICOM3170 8 Self inspection After the equipment is powered on PWR LED will stay on for 2 seconds The device will begin the initialization process the RUN LED will blink after the device completes the initialization process after 30 seconds 9 Login WEB management 1 Using cross over cable or straight through cable to connect a Ethernet port in the switch with the network card of PC through Ethernet Type the IP address of switch in IE browser such as IP is 192 168 0 2 press Enter key you can see the page as Figure9 Enter the default username admin and the default password 123 click Sign in to enter the WEB s main page The default IP address 192 168 0 2 The default username admin 10 2 3 KYLAND The default password 123 User Name admin Password eee Figure 9 Log in page
11. ual 132 KYLAND 11 Configurations to use 100M SFP module in 3170 Gigabit SFP slot Gigabit SFP modules can be used in SICOM3170 Gigabit SFP slot But if you need to use 100M SFP modules to connect a 100M fiber network please use Kyland suggested 100M SFP modules and change the configuration according to the following instructions 1 Web Interface Log in web interface click port configuration set status of GE1 GE2 as 100M full duplex and disable the Auto click Apply see picture below FE1 Enable v Enable v Enable 10M Half Off v FE2 Enable v Enable w Enable w 10 Half Off v FE3 Enable vw Enable v Enable vw 100 Full Off FE4 Enable wv Enable v Enable 10M Half Off v Fes Enable Y Enable v Enable Y im Half Off v FE6 Enable w Enable v Enable w 10M Half Off y FE7 Enable v Enable v Enable vw 10m Half Off y GE8 Enable v Enable v Enable 10 Half Off iv GE1 Enable v Enable v Disable w 100 v Full v off v GE2 Enable v Enable v Disable Y 100 y Full v Off v click OK see picture below FE1 Enable v Enable v Enable vw 10 Halt Off v FE2 Enable v Enable v a Off v FE3 Enable v Enable vi Enable w 100M Full Off v FE4 Enable y Enable 101 Half Off v FE5 eee Enable w iM Halt off v 7B A AS FE6 ES Enable wv 10m Half Off v