Home
User Guide - Balloch Security
Contents
1. Control Panel ICP SOL2 P ICP SOL3 P BOSCH en User s Guide Control Panel Table of contents Table of Contents en 3 1 Introduction 5 2 Specifications 6 3 Codepad Introduction 7 3 1 Codepad 7 3 2 Quick Codepad Operation Instructions f 33 Codepad Indicators 7 3 4 Audible Indications 9 4 Operation with TEXT LCD Codepad 10 4 1 Text Menu 10 4 1 1 Command Menu 10 4 1 2 Access Menu 11 4 1 3 System Menu 11 4 1 4 Zone Menu 12 4 1 5 Area Menu 13 4 1 6 Output Menu 13 4 1 7 Communication Menu 13 4 1 8 Parameter Menu 14 5 Operation with ICON LCD Codepad 15 5 1 Arming the System 15 5 1 1 Forced Arming 15 5 1 2 Arming in AWAY Mode 15 5 1 3 Arming in STAY Mode 1 16 5 1 4 Arming in STAY Mode 2 16 5 1 5 Programming STAY Mode 2 Zones 17 5 2 Disarming the System 17 5 3 User Codes 17 531 Adding User Radio Codes 17 5 3 2 Deleting User Radio Codes 18 5 4 Codepad Alarms 18 5 4 1 Codepad Duress Alarm 18 5 4 2 Codepad Panic Alarm 18 5 4 3 Codepad Fire Alarm 19 5 4 4 Codepad Medical Alarm 19 5 4 5 Codepad PIN Error Access Denied 19 5 5 Isolating Zones 19 5 5 1 Standard Isolating 19 5 5 2 Code to Isolate 19 5 6 Fault Analysis Mode 20 5 6 1 Fault Descriptions 21 5 7 Date and Time 22 5 8 Turning Outputs On Off 22 5 9 Reset Latching Outputs 22 5 10 Telco Arm Disarm Sequence Call Forward On Off 23 5 10 1 Telco Arm Sequence 23 5 10 2 Telco Disarm Sequence 23 5 11 Testing 24 5 11 1 Horn Speaker Test 24 Bosch Secu
2. for Step 3 5 11 5 11 1 5 11 2 5 11 3 5 11 4 5 11 5 Digit Required Number to Program Digit Required Number to Program 0 0 8 8 1 1 9 9 2 2 10 0 3 3 S i 4 4 2 5 5 4 sec Pause 3 6 6 7 7 Terminator 5 Table 5 5 Dialing Digits Testing The following functions let you confirm that your system is operating correctly Horn Speaker Test Hold the 1 key until two beeps sound The horn speaker sounds for 2 sec Bell Test Hold the 2 key until two beeps sound The bell output operates for 2 sec Strobe Test 1 Hold the 3 key until three beeps sound The strobe flashes 2 Hold the 3 key until two beeps sound The strobe stops flashing Walk Test Mode Use Walk Test Mode to test detection devices to ensure that they are operating correctly Every time you test a zone the codepad sounds one long beep and the horn speaker sounds one short beep to indicate that the zone is activated when testing 1 Enter your Master Code followed by the 7 and keys for example 25807 Three beeps sound and the STAY and AWAY indicators flash The codepad beeps once every sec while the system is in Walk Test Mode 2 Activate all zones requiring the test 3 When you finish testing all required zones press the key to exit from this mode Two beeps sound and the STAY and AWAY indicators turn off The system returns to the disarmed state Test Report
3. 24 User Property U 241 User Name 242 User Allocate 243 User Authority Table 4 3 Access Menu System Menu U I 3 System 1 31 Timer 1 311 Entry Time1 312 Entry Time2 313 Exit Time 314 Entry Guard Time For STAY Mode 315 Sensor Watch Time 316 Codepad Lockout Time 317 Auto Arm Pre AlertTime 318 Auto Arm Time 319 Auto Disarm Time 32 Codepad 321 Silent Codepad Panic Alarm 322 Silent Codepad Fire Alarm 323 Silent Codepad Medical Alarm 324 Codepad Access Denied Silent 325 Codepad Fault Beep Enable 326 Codepad Display Off after 60s 33 Arm Disarm 331 Auto Arm In STAY1 332 Single Btn Arm Enable 333 Single Btn Disarm Enable 334 Disarmed On Power Up 335 Arm Disarm Track On Power Up 336 Phone Remote Arm 337 Answer Machine Bypass On Arm Bosch Security Systems Inc User s Guide 2014 06 01b FO1U298028 12 en Operation with TEXT LCD Codepad 4 1 4 34 Fault Control Panel 341 Ignore AC Fail 342 AC Fail Report Wait Time 343 Horn Speaker Fault Monitor 344 Phone Line Fault Indicator 345 Phone Line Fault Alarm on Armed 346 Phone Line Fault Alarm on Disarm 347 Lockout Phone Line Fail Alarm U1 35 Wireless 351 RF Receiver 352 Zone RFID A
4. 01b FO1U298028 en Specifications Specifications Control Panel Temperature Range 0 C to 50 C Humidity 20 to 90 Power Source TFOO8 Plug Pack 240 V 18 VAC 1 3A Codepad Stand By Current 65 mA Current Draw in Alarm Condition 115 mA Current Draw in Alarm Condition with 105 mA Back Up Battery 7 Ah 12 VDC Rechargeable Sealed Lead Acid Battery Dimensions Case packed in carton 306 mm x 262 mm x84 mm Weight 2 5 kg Supplier Code N771 Table 2 1 Specifications Notice Test the sirens strobe and zones at weekly intervals 2014 06 01b FO1U298028 User s Guide Bosch Security Systems Inc Control Panel Codepad Introduction en 7 3 Codepad Introduction 3 1 Codepad IUI SOL TEXT IUI SOL ICON BOSCH BOSCH G Guam Cun bear ose Geer Love Crem Gece stay 0 1 away 3 2 Quick Codepad Operation Instructions 3 3 Codepad Indicators Codepad indicator Status Definition icons On Zone is unsealed a Off Zone is sealed ZONE 1 8 for ICP Se SOL2 P Flashing Fast 0 25 sec Zone is in alarm condition ZONE 1 16 for ICP on 0 25 sec off SOL3 P Flashing Slow 1 sec on 1 Zone is manually isolated or selected to sec off be isolated On System is armed in AWAY Mode A Off System is not armed in AWAY Mode AWAY Flashing twi
5. Table 4 6 Area Menu 4 1 6 Output Menu 1 6 Output 1 61 Onboard Output 62 Codepad Output 63 Extend Output 64 Siren Config 641 Siren Run Time 642 Siren Run Rate 643 Siren Sound On RF Receiver Fail Table 4 7 Output Menu 4 1 7 Communication Menu 1 7 Comm 71 Receiver Config 72 Network Config 73 Report Config 721 Network Module 1 722 A Link RSC PSWD 723 IP Destination 724 CSVIP User Name And Password 731 STAY Mode Arm Disa Report Enable 732 Arm Disa Report Only If Alarmed 1 733 First Disarm Last Arm Report 1 734 Arm Disarm Report Option 1 735 Codepad Report Option 736 Test Report Time And Interval 1 737 Test Report Only When Armed 738 Test Report On Siren Reset 1 739 Test Report Dialer Option Bosch Security Systems Inc User s Guide 2014 06 01b FO1U298028 14 en Operation with TEXT LCD Codepad 1 74 Comm Option1 Control Panel 1 741 Ring Count 742 Dialer Report Function Enable 743 Exit A Link Connection On Alarm 744 System Status Report Option 745 Use Bell 103 For FSK Format 746 DTMT Dial Pulse To 1 Digit Sec 747 Receiver1 2 Dialing Format 748 Set Up Domestic Dialing Format 1 75 Comm Option2 1 751 Telco Arming Sequence 752 Telco Disarming
6. made for that event If the call was successfully acknowledged a tone of decreasing pitch sounds Digit Required Number to Program Digit Required Number to Program 0 0 8 8 1 1 9 9 2 2 10 0 3 3 St A A D e 5 5 4 sec Pause 3 6 6 7 7 Terminator 5 Table 5 6 Domestic Dialing Telephone Digits Programming Domestic Telephone Numbers If your system is set up for domestic dialing any Master Code holder can program telephone numbers that the control panel calls in the event of an alarm How to Program Telephone Numbers 1 Enter your Master Code followed by the 2 and keys for example 25802 Three beeps sound and the STAY and AWAY indicators flash 2 Enter the any telephone number you need and press the keys for example 1 If there is telephone number already programmed they display one digit at a time by the codepad indicators and end with indicator 15 2014 06 01b FO1U298028 User s Guide Bosch Security Systems Inc Control Panel Operation with ICON LCD Codepad en 27 If there are no telephone numbers programmed indicator 15 displays and two beeps sound 3 Enter all digits of the telephone number for example 96721717 As each digit is entered the corresponding codepad indicators display 4 Press the key to exit from this function If there is more than one telephone number to program repeat step 1 to 4 5 16 3 Disable Dome
7. the 5 key until two beeps sound This displays the RF detection device reporting the RF sensor watch fault Bosch Security Systems Inc User s Guide 2014 06 01b FO1U298028 22 5 7 5 8 5 9 en Operation with ICON LCD Codepad Control Panel 6 Communication Fail A communication fail registers when the control panel fails to communicate with the receiving party such as a monitoring company mobile phone The communication fault clears once the control panel successfully reports to the receiving party A communication fail also registers when network module is disconnected or tampered To determine which receiver or module failed to communicate press and hold the 6 key 7 Output and Codepad Fail The output fault registers when the output expander B308 is disconnected or tampered The codepad fault registers when any codepad is tampered or disconnected from the control panel To determine which fault occurred press and hold the 7 key 8 Keyfob Low Battery This fault occurs when any of the RF keyfobs report a low battery condition to the control panel To determine which keyfob failed press and hold the 8 key Only keyfob 1 to 16 faults display on the codepad through zone indicator 1 to 16 Date and Time Programming the date and time is only required when you need functions such as automatic test reports automatic arming and history events to operate correctly How to Program the Date and Time 1 Ente
8. time expires the sirens activate into alarm Only your installer can program this feature Method One Enter your user code followed by the button for example 2580 Two beeps sound and the STAY indicator displays Exit Time starts counting Any zones programmed to be automatically isolated in STAY Mode 1 flash until Exit Time expires At the end of Exit Time all zones selected to be automatically isolated turn off and the codepad gives one short beep Method Two Hold down the button until two beeps sound The STAY indicator displays and Exit Time starts counting Any zones programmed to be automatically isolated in STAY Mode 1 flash until Exit Time expires At the end of Exit Time the zone indicators turn off and the codepad gives one short beep Table 5 3 How to Arm the System in STAY Mode 1 Arming in STAY Mode 2 STAY Mode 2 is only used when the perimeter and unused areas of the premise need to be armed to detect an intruder from entering the premise At the same time allowing you to move freely within an area that is automatically isolated Any Master Code or Installer Code user can program zones to be automatically isolated in STAY Mode 2 Enry Guard Timer for STAY Mode 2 When arming the system in STAY Mode 2 an optional entry timer called Entry Guard Time for STAY Mode is available Use this entry timer to delay the sirens if a zone is not automatically isolated and activated into alarm condition H
9. 61 Phone Number to program the Call Forward No Answer Sequence or 21 Phone Number to program the Call Forward Immediate Sequence To program an in the Telco Arm Sequence enter 1 and to program a in the Telco Arm Sequence enter 2 4 Press the key when finished Two beeps sound and the STAY and AWAY indicators turn off Notice To disable the Telco Arm Sequence enter the Call Forward Sequence as 5 terminator for Step 3 5 10 2 Telco Disarm Sequence Use this function to automatically disable the call forward sequence upon disarming the system How to Program the Telco Disarm Sequence 1 Enter your Master Code followed by the 3 and keys for example 25803 Three beeps sound and the STAY and AWAY indicators flash 2 Press the 2 key followed by the key to select the Telco Disarm Sequence Three beeps sound 3 Enter the Call Forward Disable Sequence for example 61 to disable the No Answer Call Forward sequence or 21 to disable the Call Forward Immediate Sequence Notice To program a in the Telco Disarm Sequence enter 2 4 Press the key when finished Two beeps sound and the STAY and AWAY indicators turn off Bosch Security Systems Inc User s Guide 2014 06 01b FO1U298028 24 en Operation with ICON LCD Codepad Control Panel Notice To disable the Telco Disarm Sequence enter the Call Forward Sequence as 5 terminator
10. 801 2 Enter the WE800EV2 keyfob number 301 to 321 you want to add followed by the button Only current keyfob number 1 to 16 displays on the ICON codepad 3 Only use auto learn mode to configure keyfob RFID Press button to switch into auto learn mode When icon numbers 1 to 16 flash press button 1 or 2 of the keyfob The panel learns the WE800EV2 Keyfob ID number and the last digit of RFID number displays on the codepad Press button to confirm A Enter button to confirm the operation or press to cancel Bosch Security Systems Inc User s Guide 2014 06 01b FO1U298028 18 5 3 2 5 4 5 4 1 5 4 2 en Operation with ICON LCD Codepad Control Panel How to Add a RADION Keyfob Set RF receiver as RADION Receiver 1 Enter your Master Code followed by 1 and the button for example 25801 2 Enter the RADION keyfob number 301 to 332 you want to add followed by the button Only current keyfob number 1 to 16 displays on the ICON codepad 3 Use manual mode or auto learn mode to configure RADION keyfob RFID In manual mode enter the 9 digit RF device ID number followed by the button Or press button to switch into auto learn mode When icon numbers 1 to 16 flash press button 1 or 2 of the keyfob The panel learns the RADION Keyfob ID number and the last digit of RFID number displays on the codepad Press button to confirm 4 Enter button to confir
11. LT indicator remains steady and the STAY and AWAY indicators flash in unison A zone indicator displays the type of fault that occurred for example Zone 1 System Fault Refer to Fault Indicators page 20 for the list of possible system faults 2 To further determine the type of fault condition press and hold down the key that corresponds to the zone indicator displayed For example if Zone 1 displayed System Fault press and hold the 1 key to display which system fault occurred 3 To exit Fault Analysis Mode and return to the disarmed state press the key The FAULT indicator continues to display and the codepad stops sounding once a min Fault Indicators Zone Fault Description Hold Down Zone Fault Condition Indicator Button Indicator 1 System Fault 1 Battery Fail Date and Time RF Receiver Fail Output 1 to 3 Fail Telephone Line Fail No BR WDNR Power Supply Fail 8 Tamper 9to 16 RF Repeater 1 to 8 Fail 2 RF Low Battery 2 1to 16 Zones 1 to 16 RF Low Battery 3 Zone Tamper Alarm 3 1to1i6 Zones 1 to 16 Tamper Alarm 4 Sensor Watch Fault 4 1to 16 Zones 1 to 16 Sensor Watch Fail 5 RF Sensor Watch 5 1to 16 Zones 1 to 16 RF Sensor Watch Fail 6 Communication Fail 6 1 Receiver 1 Fail 2 Receiver 2 Fail 3 IP Module 1 Fail 4 IP Module 2 Fail 2014 06 01b FO1U298028 User s Guide Bosch Security Systems Inc Control Panel Operation with ICON LCD Codepad en 21 Zo
12. N LCD Codepad Control Panel Notice If your installer programmed answering machine bypass call the control panel twice to make a connection with the system For example call the telephone number your control panel is connected to and let the call ring no more than four times Hang up the telephone Wait a minimum of 8 sec before you calling the control panel again 5 16 5 16 1 5 16 2 Domestic Dialing Use domestic dialing can be used to call your mobile phone or a relative friend if your control panel activates an alarm Up to four different telephone numbers can be programmed for the control panel to call when an alarm occurs Only your installer can program the system to report in the domestic format The Master Code holder can change the telephone numbers at any time Acknowledging Domestic Calls When an alarm condition occurs the system calls the first programmed telephone number When you answer an incoming call the system repeatedly emits a siren tone followed by a pause continuously for 10 times for example siren tone pause siren tone and pause If you do not acknowledge the call from the control panel during a pause between siren tones the control panel hangs up after 10 times and recall the same call number for 2 times If the system still can t receive the acknowledge the system calls the next telephone number Pressing the key for 1 sec to 3 sec during the pause acknowledges the call No further calls are
13. Sequence 753 Delay Alarm Report Time 1 754 Kiss Off Wait Time 755 Delay Siren Until Transmit Over 756 Extend Wait For Handshake 757 Upload Download Enable 758 Callback Phone Number Request 759 Callback Phone Number Table 4 8 Comm Menu 4 1 8 Parameter Menu 8 Parameter 1 81 Addr Program 82 Addr Auto Step 83 Adapter 1 831 Test Adapter 832 Read Adapter 833 Write Adapter Table 4 9 Parameter Menu 2014 06 01b FO1U298028 User s Guide Bosch Security Systems Inc Control Panel Operation with ICON LCD Codepad en 15 5 Operation with ICON LCD Codepad 5 1 Arming the System There are several ways to arm the system depending on whether you are Leaving the premises and require all active zones to be in a ready state for an intruder Remaining in the premises and only require part of the system to be in a ready state for and intruder If a zone is not sealed at the end of Exit Time the zone is automatically isolated and constantly displayed on the remote codepad The zone becomes an active part of the system when the zone is restored For example if a window is left open after Exit Time expired the window is not an active part of the system until the window is closed Opening the window after Exit Time expired causes an alarm condition Below table defines the different methods for arming the
14. This feature applies if your system reports using the telephone or network modules By holding down the 9 key until two beeps sound the system sends a Test Report 2014 06 01b FO1U298028 User s Guide Bosch Security Systems Inc Control Panel 5 12 5 13 5 14 5 15 Operation with ICON LCD Codepad en 25 Event Memory Use this function to replay the last 256 events that the system recorded The event memory history replays all system faults all alarms and the arming disarming of the system in AWAY Mode STAY Mode 1 and STAY Mode 2 How to Enter Event Memory Enter your Master Code followed by 8 and the button for example 25808 Three beeps sound The last 256 events display one at a time by the codepad indicators starting with the most recent event A beep sounds as each event displays Day Alarm Day alarm monitors a combination of zones during the disarmed state It beeps the codepad buzzer if activated Only your installer can program zones 1 to 4 to operate for day alarm Example A day alarm can be configured for the front door of a shop with a pressure mat or electronic beam that customers activate as they enter the shop When customers step on the pressure mat or break the electronic beam the codepad buzzer beeps How to Turn Day Alarm On Hold down the 4 key until three beeps sound Day alarm turns on All zones programmed for day alarm operation cause the codepad buzzer to beep during the di
15. When you enter the premises after the system is armed in AWAY mode or if you armed the system in STAY Mode 1 or STAY Mode 2 you must disarm the system to disable detection devices that activate an alarm If there was an alarm condition prior to disarming the system a flashing zone indicator displays indicating a previous alarm on that zone How to Disarm the System Enter your user code followed by the button for example 2580 Two beeps sound User Codes Adding User Radio Codes Only the Master Code holder can add or change other system user codes including the Master Code Up to 32 user codes radio user codes can be programmed to operate the system How to Add a User Code 1 Enter your Master Code followed by 1 and the button for example 25801 Three beeps are heard and the STAY and AWAY indicators flash 2 Enter the User Code number 1 to 32 followed by the button for example 2 User 2 8 User 8 Two beeps are heard and the selected user number displays on the codepad indicators 3 Enter the digits required for the new code followed by the button for example for User Code 5768 enter 5768 Two beeps are heard and the STAY and AWAY indicators turn off To add or change other User Codes repeat this procedure as many times as required How to Add a WE800EV2 Keyfob Set RF receiver as WE800EV2 Receiver 1 Enter your Master Code followed by 1 and the button for example 25
16. ce a sec with Setting STAY Mode 2 zones STAY indicator Bosch Security Systems Inc User s Guide 2014 06 01b FO1U298028 8 en Codepad Introduction Control Panel Codepad indicator Status Definition icons On System is armed in STAY Mode 1 or K STAY Mode 2 Off System is not armed in STAY Mode 1 or STAY Mode 2 STAY Flashing twice a sec Zone isolating mode Flashing twice a sec with AWAY indicator Setting STAY Mode 2 zones Flashing once every 3 sec Day alarm status day alarm turned on Programming Mode On System is disarmed se On AC MAINS power normal Flashin AC MAINS supply has failed MAINS g ge On There is a system fault that needs to be AN rectified Off The system is normal there are no FAULTS faults Flashing There is a system fault that needs to be acknowledged Flashing These two indicators flash when you enter Installers Programming Mode or use any Master Code function The OFF indicator lights when the system is disarmed and flashes when a zone becomes unsealed when disarmed The indicator stops flashing when all zones are sealed The ON indicator lights when the system is armed and flashes when an alarm occurs The indicator is reset after a valid User Code is entered 2014 06 01b F01U298028 User s Guide Bosch Security Systems Inc Control Panel 3 4 Audible Indications Co
17. delay hand held radio remote control A device used to arm and disarm a security system or to cause a panic alarm 2014 06 01b FO1U298028 User s Guide Bosch Security Systems Inc Control Panel Term Glossary of Terms en 29 Description isolate A method of manually disabling isolating one or more zones before arming the system master code A numeric code used for arming and disarming the system and for allowing access to all functions available through the codepad monitoring station A secure location where a digital receiver monitors a number of alarm systems and deciphers their alarm transmission reports so the operator can advise the appropriate authorities to take immediate action panic A condition or type of alarm in which the user requires either immediate police or medical assistance sealed Refers to a zone s status If a zone is sealed the detection devices are not violated and the zone indicator is not lit that is a reed switch is closed or a detector is on standby waiting for an intrusion sensor watch A feature that allows the control panel to recognize when detection devices might have stopped working Sensor watch monitors the operation of a zone over a programmed time period silent alarm An alarm that sounds only at a remote location and gives no obvious local indication that an alarm was sent out STAY Mode 1 A condition that automa
18. depad Introduction en 9 Below table defines the audible indicators given out by the codepad buzzer Audible Indicator Definition One short beep A button key was pressed on the codepad or Exit Time ended when armed in STAY Mode 1 or STAY Mode 2 Two short beeps The system accepted your code Three short beeps The requested function was executed One long beep Indicates the last 10 seconds of Exit Time when armed in AWAY Mode or the requested operation was denied or aborted Indicates codepad panic fire medical alarm operation One beep every sec Walk Test Mode is currently active One short beep every min There is a system fault waiting to be acknowledged One beep every 4 sec During Auto Arming Pre Alert Time the warning before automatic arming takes place One beep every 2 sec During Exit Time when armed in AWAY Mode Table 3 1 Audible Indicators Bosch Security Systems Inc User s Guide 2014 06 01b FO1U298028 10 4 1 1 en Operation with TEXT LCD Codepad Operation with TEXT LCD Codepad Text Menu Control Panel Main Menu AUI 1 Command U I 2 Access U I 3 System U1 4 Zone 1 5 Area 1 6 Output 1 7 Comm 8 Parameter Table 4 1 Menu Structure Text A or U or l in brackets instruct you the text menu that displays on the codepad for different code hol
19. ders A All can access no code required To enter the text menu simply press only 1 Command displays U User code holder with authority levels can access Enter the User Code followed by to enter the menu Installer code holder can access Enter the Installer Code followed by or to enter the menu all menu items display Command Menu AUI 1 Command U 11 Arm U 111 AWAY Arm U 112 STAY 1 Arm U 113 STAY 2 Arm U 114 AWAY Arm All AU I 12 Inquire AU I 121 Fault Analysis U I 122 Event Recall AU I 13 System U 131 Set Date amp Time AU I 132 Day Alarm UI 133 Arm Disa Seq 134 Report Monitor AUI 135 ModemCall Init Ul 136 Domestic Phone U I 137 VersionDisplay 138 FactoryDefault U 139 System Reset 1 14 RF Diagnose 1 141 RF Zone 1 142 RF Keyfob 1 143 RF Repeater 2014 06 01b FO1U298028 User s Guide Bosch Security Systems Inc Control Panel 4 1 2 4 1 3 A U1 15 Test Operation with TEXT LCD Codepad en 11 AU1 151 Horn Speaker A U1 152 Bell Test AU I 153 Strobe Test U I 154 Walk Test AU1 155 Test Report U 16 Zone Bypass U 17 Output On Off Table 4 2 Command Menu Access Menu U I 2 Access 21 Installer Code U 22 User Code 23 Access Retry U I
20. es If any User Code has this priority level the method of standard isolating does not function How to Isolate a Zone 1 Press the button followed by your User Code and the button again to enter the Isolating Mode for example 2580 Three beeps sound and the STAY indicator flashes Bosch Security Systems Inc User s Guide 2014 06 01b FO1U298028 20 en Operation with ICON LCD Codepad Control Panel 2 Enter the zone number 1 to 8 followed by the button for example 1 Zone 1 2 Zone 2 Each zone to be isolated has a corresponding zone indicator that flashes If you selected an incorrect zone to be isolated enter the incorrect zone number again followed by the button Repeat Step 2 if more than one zone is to be isolated until all zones to be isolated are selected 3 Press the button after all selected zones are isolated Two beeps sound and the system returns to the disarmed state 5 6 Fault Analysis Mode If a fault occurs the FAULT or MAINS indicators flash and the codepad beeps once every min If the AC MAINS supply fails the MAINS indicator flashes until the AC MAINS supply is restored Pressing the button once acknowledges the fault and stops the codepad from beeping once every min How to Determine the Type of System Fault To determine which system fault occurred enter Fault Analysis Mode by following the steps below 1 Hold down the 5 key until two beeps sound The FAU
21. g Outputs This feature is only applicable if your installer programmed an output to latch remain on until you acknowledge the event that occurred How to Reset Latching Outputs Hold down the 7 key until two beeps sound The output resets 2014 06 01b FO1U298028 User s Guide Bosch Security Systems Inc Control Panel Operation with ICON LCD Codepad en 23 5 10 Telco Arm Disarm Sequence Call Forward On Off Use this feature to program the Telco Arm Sequence and Telco Disarm Sequence 5 10 1 Telco Arm Sequence Use to program the Call Forward Immediate On sequence or Call Forward No Answer sequence to automatically operate when you arm the system in the AWAY Mode This feature is only available if your telecommunications provider has the callforward option available Call Forward Immediate On You can redirect calls to anywhere in Australia When Call Forward is turned on your telephone does not ring Call Forward No Answer When your telephone is not answered within 20 sec this feature redirects all incoming calls to another number anywhere in Australia You can still make outgoing calls How to Program the Telco Arm Sequence 1 Enter your Master Code followed by the 3 and keys for example 25803 Three beeps sound and the STAY and AWAY indicators flash 2 Press the 1 key followed by the key to select the Telco Arm Sequence Three beeps sound 3 Enter the Call Forward Sequence for example
22. ler to program this function Isolating Zones Use isolating zones to manually disable one or more zones before arming the system Once a zone is isolated you can access that zone during the armed state without activating an alarm For example you need to isolate a zone because before arming the system a PIR detector may be false alarming or you need to leave a pet inside a particular zone while away Isolating zones is performed by one of two methods Method two is optional and only allows those user codes programmed by your installer to have access to isolate zones Standard Isolating Standard isolating allows all operators to isolate zones without knowing a valid user code How to Isolate a Zone 1 Press the button twice to enter the Isolating Mode Three beeps are heard and the STAY indicator flashes 2 Enter the zone number 1 to 8 followed by the button for example 1 Zone 1 2 Zone 2 Each zone to be isolated has a corresponding zone indicator that flashes If you selected an incorrect zone to be isolated enter the incorrect zone number again followed by the button Repeat Step 2 if more than one zone is to be isolated until all zones to be isolated are selected 3 Press the button after all selected zones are isolated Two beeps are heard and the system returns to the disarmed state Code to Isolate This method restricts only those User Codes with the Code to Isolate priority level to isolate zon
23. llows the system to disarm automatically at the same time each day in AWAY Mode or STAY Mode 1 AWAY Mode The mode used to arm your system when you leave your premises codepad A device that allows you to perform all functions such as arming disarming and programming of your alarm system day alarm Programming that allows a combination of zones to be monitored while the system is disarmed detector A unit installed as a satellite component in a security system designed to detect an intruder within a protected area Some common forms of detection devices are passive infrared smoke photo electric beams reed switches and vibration sensors disarmed A system status that does not accept alarms except for 24 Hour zones dynamic battery testing A method used to monitor and test the condition of your backup battery entry delay A programmed delay of the system alarm responses that allows a person to enter a building through the entry door to turn the system off external Any device connected to a security system such as a detector equipment codepad or siren force arming hand over delay A method of overriding the safety feature that prevents arming with a faulted zone on a control panel If a system is armed and Zone 1 is violated the entry delay starts timing If Zone 2 is violated the entry delay time is handed over to the Zone 2 and so on to Zones 3 and 4 This is known as sequential hand over
24. m the operation or press to cancel Deleting User Radio Codes Only the Master Code holder can delete other system user codes How to Delete a User Code 1 Enter your Master Code followed by 1 and the button for example 25801 Three beeps sound and the STAY and AWAY indicators flash 2 Enter the user code number 1 to 32 followed by the button for example 2 User 2 16 User 16 Two beeps sound and the selected user number displays on the codepad indicators 3 Press the button to delete the selected User Code Two beeps are heard and the STAY and AWAY indicators turn off To delete other User Codes repeat this procedure as many times as required How to Delete a WE800EV2 Keyfob 1 Enter your Master Code followed by 1 and the button 2 Enter the WE800EV2 keyfob number 301 to 321 you want to delete followed by the button 3 Press the button to delete the WE800EV2 Keyfob How to Delete a RADION Keyfob 1 Enter your Master Code followed by 1 and the button 2 Enter the RADION keyfob number 301 to 332 you want to delete followed by the button 3 Press the button to delete the RADION Keyfob Codepad Alarms Codepad Duress Alarm A codepad duress alarm is used as a silent hold up alarm This only occurs when the number 9 is added to the end of any valid user code being used to disarm the system for example 25809 A duress alarm is only useful if your sy
25. nd Input Option U I 353 Keyfob RFID 354 Repeater RFID 355 RF Supervision Time 356 RF Jam Sensitivity 357 RF RECE Jam Tamper Siren Alarm 358 RFKF Btn4 Arm In STAY1 359 RF Arm Disarm Strobe Indicate U I 36 System Table 4 4 System Menu Zone Menu U I 361 Home Message Option 362 Button Factory Default Enable 363 Alarm Memory Reset On Disarm 364 STAY Indicator For Day Alarm 365 Digit 3 For Codepad Duress Alarm 366 Siren amp Strobe Output In STAY 367 Speaker Beep Volume U1 4 Zone 1 41 Zone Config 42 Zone Allocate U I 43 Zone Name 1 44 Day Alarm Zone U I 45 STAY2 Zone 46 EOL Resistor 47 Zone State Rpt 1 48 Swing Shutdown 481 Siren Swing Shutdown Count 482 Dialer Swing Shutdown Count 1 49 Zone Option 1 491 Silent Zone Tamper Alarm 492 Unseal Zone That Fail Monitor 493 Bosch Smart Lockout Enable 494 Zone Pulse Cnt Handover Enable 495 Handover Delay In Order Table 4 5 Zone Menu 2014 06 01b FO1U298028 User s Guide Bosch Security Systems Inc Control Panel 4 1 5 Area Menu Operation with TEXT LCD Codepad en 13 1 5 Area 51 Codepad Area 52 Area Option 521 Arm Disarm All Areas Once 522 Reset Siren From Any Area
26. ne Fault Description Hold Down Zone Fault Condition Indicator Button Indicator 7 Output and 7 2 Output Expander Fail Codepad Fail 3 to 6 Codepad Fail 8 Keyfob Low Battery 8 1 to16 Keyfob 1 to 16 Low Battery Table 5 4 Fault Indicators 5 6 1 Fault Descriptions 1 System Fault A system fault only displays when any of the following faults occur After entering Fault Analysis Mode press and hold the 1 key to determine which of the following faults occurred Low Battery Fault A low battery fault registers when the system detects a low capacity back up battery The system automatically performs a battery test every four hours and every time you arm the system Date and Time The date and time fault registers every time the system is powered down Refer to Date and Time page 22 to program the date and time RF Receiver Fail The RF receiver fault registers once the system detects that the wireless receiver unit is disconnected tampered or jammed Output 1 to 3 Fail This fault registers when the system detects any output is disconnected This fault clears once any output is reconnected Your installer must program the system for this feature to operate Telephone Line Fail A telephone line fault registers when the system detects that the telephone line is disconnected from the control panel Your installer must program the system for this feature to operate Power Supply Fail This fault occurs when AUX po
27. o Arm the System in AWAY Mode Bosch Security Systems Inc User s Guide 2014 06 01b FO1U298028 16 en Operation with ICON LCD Codepad Control Panel 5 1 3 5 1 4 Arming in STAY Mode 1 STAY Mode 1 is only used when the perimeter and unused areas of the premises need to be armed to detect an intruder from entering the premises At the same time you can move freely within an area that is automatically isolated Only your security company can program zones automatically isolated in STAY Mode 1 There are two different methods for arming the system in STAY Mode 1 Method one is standard and always operates Method two is optional and may be disabled by your installer if you do not want to use single button arming Entry Guard Timer for STAY Mode 1 When arming the system in STAY Mode 1 an optional entry timer called Entry Guard Time for STAY Mode is available Use this entry timer to delay the sirens if a zone is not automatically isolated and activated an alarm condition Entry Guard Time For STAY Mode is the delay time used for all zones except 24 hour zones when the system is armed in STAY Mode 1 or STAY Mode 2 If the Entry Guard Time for STAY Mode is programmed and a zone was not automatically isolated is activated the codepad beeps twice a sec until the entry timer expires or the system is disarmed If the alarm condition is not reset by entering your user code followed by the button such as 2580 before the entry
28. ow to Arm the System in STAY Mode 2 Hold down the 0 button until two beeps sound The STAY indicator displays and Exit Time starts counting Any zones programmed to be automatically isolated in STAY Mode 2 flash until Exit Time expires At the end of Exit Time all zones selected to be automatically isolated extinguish and the codepad emits one short beep 2014 06 01b FO1U298028 User s Guide Bosch Security Systems Inc Control Panel 5 1 5 5 2 5 3 5 3 1 Operation with ICON LCD Codepad en 17 Programming STAY Mode 2 Zones Programming zones to be automatically isolated in STAY Mode 2 are only carried out if you have a Master Code or Installer Code How to Program STAY Mode 2 Zones 1 Enter your Master Code or Installer Code followed by 4 and the button for example followed 25804 Three beeps sound and the STAY indicator flashes 2 Enter the zone number to be automatically isolated followed by the button for example 1 Zone 1 2 Zone 2 The selected zone flashes If you make a mistake enter the same zone number followed by the button to clear the incorrect zone To select additional zones to be automatically isolated in STAY Mode 2 repeat Step 2 as many times as required 3 Press the button to exit this mode when you finish selecting all zones to be automatically isolated in STAY Mode 2 Two beeps sound and the STAY and AWAY indicators turn off Disarming the System
29. r your Master Code followed by 6 and the key for example 25806 Three beeps sound and the STAY and AWAY indicators flash 2 Enter the day month year hour and minute DD MM YY HH MM format for example DD day of the month MM month of the year YY current year HH hour of the day MM minute of the day To program the hour of the day use the 24 00 hour format 3 Press the button to exit and return to the disarmed state Two beeps sound and the STAY and AWAY indicators turn off If a long beep sounds an error was made when entering the date and time Turning Outputs On Off This feature is only applicable if your installer set up an output that can be turned on or off by the codepad The output programmed by your installer can control a pool pump or outside lighting Up to three separate outputs can be programmed How to Turn an Output On or Off 1 Enter your Master Code followed by 5 and the key for example 25805 Three beeps sound and the STAY and AWAY indicators flash 2 Enter the output number 1 to 3 3 Press the key to turn the output on or press the key to turn the output off Three beeps sound if the output is turned on and two beeps sound if the output is turned off Repeat Step 2 and Step 3 if more than one output is required to be turned on or off 4 Press the key to exit from this function Two beeps sound and the STAY and AWAY indicators turn off Reset Latchin
30. rity Systems Inc User s Guide 2014 06 01b FO1U298028 4 en Table of Contents Control Panel 5 11 2 Bell Test 24 5 11 3 Strobe Test 24 5 11 4 Walk Test Mode 24 5 11 5 Test Report 24 5 12 Event Memory 25 5 13 Day Alarm 25 5 14 Codepad ID Buzzer Tone 25 5 15 Remote Arming by Telephone 25 5 16 Domestic Dialing 26 5 16 1 Acknowledging Domestic Calls 26 5 16 2 Programming Domestic Telephone Numbers 26 5 16 3 Disable Domestic Dialing 27 6 Glossary of Terms 28 2014 06 01b FO1U298028 User s Guide Bosch Security Systems Inc Control Panel Introduction en 5 1 Introduction Congratulations on selecting the ICP SOL2 P ICP SOL3 P Control Panel to protect you and your property To obtain the most from your unit take time to read through this manual and familiarize yourself with the numerous outstanding operating features of this system In all aspects of planning engineering styling operation convenience and adaptability we have sought to anticipate your every possible requirement Programming simplicity and speed were some of the major considerations and we believe that our objectives in this area were more than satisfied This manual explains all aspects of operating the control panel All system parameters and options are detailed however suitability is left up to the individual Every system can be tailored to meet all requirements quickly and easily Bosch Security Systems Inc User s Guide 2014 06
31. sarmed state when activated How to Turn Day Alarm Off Hold down the 4 key until two beeps sound Day alarm turns off Codepad ID Buzzer Tone 1 Hold down the 8 key until the desired buzzer tone is reached 2 Press the key to exit There are 50 different tones from1500 Hz to 5000 Hz If multiple codepads are installed each codepad can have a different tone If the system is partitioned the codepad display a number identifying which area the codepad belongs Remote Arming by Telephone Arm your system from any remote location using the telephone For security reasons the system cannot be disarmed using this method Your installer must program this feature to operate How to Remotely Arm Your System by Telephone 1 Call the telephone number connected to your control panel 2 When the control panel answers the incoming call a short jingle sounds To arm the system press the key on the touch tone telephone for 1 sec to 3 sec If you hear modem tones when the control panel answers the incoming call the system was programmed for remote programming functions by your installer Wait for a pause between the tones before pressing the key After releasing the key on the touch tone telephone two beeps sound indicating that the system is armed in AWAY Mode 3 Hang up the telephone and the system remains armed Bosch Security Systems Inc User s Guide 2014 06 01b FO1U298028 26 en Operation with ICO
32. stem is reporting back to a monitoring station Domestic reporting such as a mobile phone cannot decipher which type of alarm occurred Codepad Panic Alarm An audible alarm activates when you press the 1 and 3 keys or the and keys simultaneously Contact your installer to disable the codepad panic alarm function or to silence the codepad panic alarm 2014 06 01b FO1U298028 User s Guide Bosch Security Systems Inc Control Panel 5 4 3 5 4 4 5 4 5 5 5 5 5 1 5 5 2 Operation with ICON LCD Codepad en 19 Codepad Fire Alarm The horn speaker emits a distinct fire sound when you press the 4 and 6 keys simultaneously Contact your installer to disable the codepad fire alarm function or to silence the codepad fire alarm Codepad Medical Alarm An audible codepad Medical Alarm activates when you press 7 and 9 simultaneously Contact your installer to disable the codepad medical alarm function or to silence the codepad medical alarm Codepad PIN Error Access Denied Codepad PIN error restricts the number of times an invalid user code can be used in an attempt to operate the system When the number of incorrect code attempts equals the number programmed by your installer the system activates an alarm condition If reporting back to a security monitoring station the system sends an Access Denied report To shutdown and lockout a codepad for a period of time 0 sec to 150 sec ask your instal
33. stic Dialing To cancel domestic dialing for example you are moving and do not want the system to continue calling your mobile phone enter the following sequence 1 Enter your Master Code followed by the 2 and keys for example 25802 Two beeps sound and the STAY and AWAY indicators flash 2 Enter the telephone number you need to cancel and press the keys for example 1 3 Press the key followed by the 5 and keys for example 5 The STAY and AWAY indicators are disabled Bosch Security Systems Inc User s Guide 2014 06 01b FO1U298028 28 6 en Glossary of Terms Control Panel Glossary of Terms Term Description 24 hour zone A monitored input where tamper switches and emergency switches can be connected If one of these switches is violated at any time whether the system is armed or disarmed an alarm is reported alarm condition The status when an alarm system is armed and one of the detection devices is violated A 24 Hour zone for example a smoke detector can activate when the system is armed or disarmed answering machine bypass A condition that enables connection with the control panel for remote arming or remote programming operations when there is an answering machine or facsimile machine on the same telephone line Armed System ON A status in which the system is ready to accept alarms automatic arming Programming that a
34. system Mode Arming Method AWAY Mode Arms the entire system Refer to Arming in AWAY Mode page 15 STAY Mode 1 Arms all zones except those programmed to be automatically isolated by the installer Refer to Arming in STAY Mode 1 page 16 STAY Mode 2 Arms all zones except those programmed to be automatically isolated by the Master Code holder Refer to Arming in STAY Mode 2 page 16 Table 5 1 Arming Methods 5 1 1 Forced Arming The feature of arming the system when a zone is not sealed is known as forced arming If the system does not arm and a long beep is heard forced arming is not permitted If this is the case you must ensure that all zones are sealed or manually isolated before you can arm the system Refer to Isolating Zones page 19 5 1 2 Arming in AWAY Mode When you leave your premises and require all zones to be in a ready state to detect intrusion arm the system in AWAY Mode There are two different methods for arming the system in AWAY Mode Method one is standard and always operates Method two is optional and can be disabled by your installer if you do not want to use single button arming Method One Enter your user code followed by the button for example 2580 Two beeps sound and the AWAY indicator displays Exit Time starts counting Method Two Hold down the button until two beeps sound The AWAY indicator displays and Exit Time starts counting Table 5 2 How t
35. tically isolates certain zones when the security system is armed in this mode Only the installer can program these zones STAY Mode 2 A condition that automatically isolates certain zones when the security system is armed in this mode The Master Code holder can program these zones telco arming sequence A feature that automatically diverts a telephone number to another telephone when a security system is armed in AWAY Mode the same as using call forwarding telco disarming An automatic suspension of diverting of the telephone when the system sequence is disarmed unsealed Refers to a zone s status If a zone is unsealed the detection devices are violated and the zone indicator is lit that is a reed switch is open or a detector noted an intrusion user code A numeric code used to arm and disarm the system zone A monitored input used to activate an alarm A zone might be set up to activate an alarm only when the system is armed or to operate whether the system is armed or disarmed Table 6 1 Glossary of Terms Bosch Security Systems Inc User s Guide 2014 06 01b FO1U298028 Bosch Security Systems Inc 130 Perinton Parkway Fairport NY 14450 USA www boschsecurity com Bosch Security Systems Inc 2014
36. wer supplies fails 12V power fails or SDI2 Bus power fails Contact your installer as soon as this fault displays Tamper This fault occurs when the system detects the control panel is tampered RF Repeater Fail The RF repeater 1 to 8 fault registers once the system detects that the wireless repeater is disconnected tampered or jammed 2 RF Low Battery This fault occurs when any of the RF wireless devices report a low battery condition to the control panel While in Fault Analysis Mode press and hold the 2 key until two beeps sound This displays the zone reporting the RF Low Battery fault 3 Zone Tamper Fail This fault occurs when any zone with tamper becomes an open circuit Press and hold the 3 key until two beeps sound This displays the zone reporting the tamper fail fault 4 Sensor Watch Fault A sensor watch fault registers because one or more detection devices failed to detect any movement during the disarmed state for the time period programmed by your installer The fault clears once the zone in question detects movement and resets Press and hold the 4 key until two beeps sound This displays the zone reporting the sensor watch fault 5 RF Sensor Watch An RF sensor watch fault registers because one or more RF detection devices fails to communicate to the RF radio receiver for the time period programmed by your installer The fault clears once the RF device in question successfully transmits to the RF radio receiver Press and hold
Download Pdf Manuals
Related Search
Related Contents
APW-896/IP-420 MAUAL DE INSTRUCCIONES(ESPAÑOL) MSI G52-S9617X1 User's Manual Ficha informativa - ECHA Samsung Frigorífico Side By Merlin 2 - Tien Versand Cables Direct B5-110Y networking cable 取扱説明書 Strong SRT 7100 TV set-top boxe Page 1 Page 2 一 本資料は、 核燃料サイクル開発機構の開発業務を George Foreman GR2080B Use & Care Manual Copyright © All rights reserved.
Failed to retrieve file