Home

CIE-H10 User`s Manual

image

Contents

1. Connection Mode Passive Connection Multiple Connection 1 Peer Port You can download the latest version of ezManager on the Download gt gt Utility page on our website Zen Sollae Systems Co Ltd 15 wu http www ezTCP com CIE H10 User s Manual Ver 3 1 2 2 Test operation 2 2 1 Modbus TCP Test This is for checking the operation of Input and output ports of the CIE H10 via Modbus TCP In this instruction offered Modbus TCP test program was used Run ezManager Then you can show the window like the figure below WW ezTCP Manager v3 1K 2012 05 31 10 1 0 100 Intel 21140 Based PCI Fast Ethernet Adapter Generic 2 Packet Scheduler Minipore elf dIE Search ezTCP mc lo seria Network serial Port 1 0 Port opcion Product eremo 7 ver 1 48 HAC Address oo so s o7 so fis eaa Network Search Results 1 poe Local IP Address o i o i 1 0 1 Use static IP address C Obtain an IP Automatically DHCP Subnet Mask ERAR C Obtain an IP Automatically PPPoE Gateway IP PPPoE ID PPPoE Password D 0 0 0 obtain DNS Server kddress Automatically DNS IP Address 0 0 o 0 Obtain an IP From The First Received Packet M TCP IP Connection Peer Address IPv6 10 1 0 1 pisapis z tic 1 Peer Port EUI bo Address z Local IP Address 1 Gateway IP DNS IP Address Start I View Comment S
2. serial PC CIE H10 Figure 1 2 serialized Modbus TCP Internet Switch Sensors switches digital input digital input Modbus TCP CIE H10 1 INTERNET CIE H10 2 Master Slave Figure 1 3 internet switch Serial Switch Sensors switches digital input digital input Serialized Modbus TCP CIE H10 1 serial CIE H10 2 Master Slave Figure 1 4 serial switch Souad Sollae Systems Co Ltd 6 http www ezTCP com CIE H10 User s Manual Ver 3 1 Macro mode Automatic Control by MACRO digital gt output CIE H10 m m Figure 1 5 macro mode Serial Device Server serial devices remote host 1 Figure 1 6 serial device server 1 3 Components The CIE H10 s body 5V Power Adapter RS232C Cable for PC option Adapter for DIN rail option Dry Contact Adapter option Souad Sollae Systems Co Ltd 7 peed peed http www ezTCP com CIE H10 User s Manual Ver 3 1 1 4 Specification 1 4 1 H W specification TES Power Size 153mm x 126mm x 32mm Weight Approximately 530g CPU ARM7 Core Digital Input 8 ports with photo couplers Digital Output 8 ports with relays Interfaces DSUB 9 pins male Ethernet 10Base T or 100Base TX Auto Sensing Auto MDI MDIX Cable Auto sensing Temperature Operate 0 55 C Storage 40 85 C E CE F690501 SP EMC000976 Certification MIC SLS CIE H10 Environment Follows Europe RoH
3. 18 3 COMPUTATION EE 19 3 1 Configuration with ezManager ENEE 19 311 Configuration via LAN 19 312 Configuration GAS AR RE EN 20 3 2 eommand ee 21 4 Operation Mode issie sesse ees bees E ee De Nege DE 22 4 1 What is the Operation Mode 22 4 2 How to chage the mode to another 22 4 3 Comparison of the each mode ENEE 23 44 Normal Mod ER EE t tet i a Ute a E R Eesi 23 5 Methods for I O conttol EE GENE ee Ne RESTE ERE IET ORE SER E EN EES Es 24 Souad Sollae Systems Co Ltd 2 http www ezTCP com CIE H10 User s Manual Ver 3 1 51 WEE 511 Related Parameters ettet 512 Modbus TCP Slave Mode 513 Modbus TCP Master Mode ee 514 TCP Connection Modes rre 5 15 Initial Output V lue rtt CAN N UM EE EE 5 2 Serialized Modbus TCP een 5 3 Macro Mod ES EE deris 5 3 1 Operat lsmeseninoniemicnissinnisiosiiniii inii re nie deae A dec seite deio 5 23 Expression example ttt 54 EC RE 541 Changing port number for HTTP 542 Uploading Users Web Page 6 Communication Mode sesse ee eee eene nene ee ee ee ee 6 1 TEP SENE RE RE EE 611 OSSE EE EE N toetbede EE 62 Le RTE e 624 OUES EE N O22 ATV 2E EE EI N e DEET DEE 6 3 1 ee 6 5 2 SE eege Geier 641 Key DH 642 EE H System Management sesse esse esse ese ee ee Ge ee Ge ee Ge 7 1 Upgrading Firmware DANN I Ic Al PROCOSSOS N Ee EA 72 Changing Webpage ENEE EE E ee OE AE 7 3 Sta
4. to the H10 Data 678 has arrived H10 sends data from the remote host to the serial device 1 second has passed H10 sends data 678 based on the Data Frame Interval S2 Sollae Systems Co Ltd 41 http www ezTCP com CIE H10 User s Manual Ver 3 1 Dynamic Update of Peer host This is a function that the CIE H10 automatically sets its peer host with information of the last packet which is received from network In the packet the source address and port number is used Table 6 11 setting for dynamic update of peer host function Parameter Peer Address Peer Port Figure 6 8 Time chart for dynamic update of peer host Table 6 12 descriptions of each state State Remote host 2 sends data to H10 H10 sets host 2 to peer host Remote host 1 sends data to H10 H10 updates host 1 to peer host Remote host 2 sends data again to H10 H10 updates host 2 to peer host H10 can communicate with remote host 2 The data ABC D I FGH are from the serial port of the CIE HIO in the above figure Souad Sollae Systems Co Ltd 42 http www ezTCP com CIE H10 User s Manual Ver 3 1 7 System Management 7 1 Upgrading Firmware 7 1 1 Firmware Firmware is a type of software for operation of the CIE H10 If there are needs for adding function or fixing bugs the firmware will be modified and released We recommend that users
5. Customer Support http www eztcp com en support 10 2 Warranty 10 2 1 Refund Upon the customer s request to refund the product within two weeks after purchase Sollae Systems will refund the product 10 2 2 Free Repair Services For product failures occurring within 2 years after purchase Sollae Systems provides free repair services or exchange the product However if the product failure is due to user s fault repair service fees will be charged or the product will be replaced at user s expense 10 2 3 Charged Repair Services For product failures occurring after the warranty period 2 years or resulting from user s fault repair service fees will be charged and the product will be replaced at user s expense S2 Sollae Systems Co Ltd 60 http www ezTCP com CIE H10 User s Manual Ver 3 1 10 3 Precaution Sollae Systems is not responsible for product failures occurring due to user s alternation of the product Specifications of the product are subject to change without prior notice for performance improvement Sollae Systems does not guarantee successful operation of the product if the product was used under conditions deviating from the product specifications Reverse engineering of firmware and applications provided by Sollae Systems is prohibited Use of firmware and applications provided by Sollae Systems for purposes other than those for which they were designed is prohibite
6. Interval is available on configuration For more information about this please refer to the Notify IP Change on the Download Technical Documents menu of our web site S2 Sollae Systems Co Ltd 52 http www ezTCP com CIE H10 User s Manual Ver 3 1 8 2 2 Sending MAC Address Sending MAC Address is a function that the CIE H10 sends its MAC address to the remote host right after the connection is established By using this function a server can identify multiple devices with the information Network Serial Port I O Port opeens D Option v elnet v IPv4 Address Search v iSend MAC Address Debugging Message 55 Multiple Connection E SSH Con 1n ESE EE I Figure 8 2 setting of Sending MAC Address function Move to the Option tab Check the Send MAC Address option 8 2 3 Debugging Message By using Debugging option users can receive debugging messages from the CIE H10 on the network When you are facing a problem about the TCP connection or data communication please use this function and send us the stored file We can use it for finding out the reason of your problem Debugging messages are broadcasted to entire network via UDP so it might cause serious network traffic Remember you should turn the option off after using it Setting debugging option Network Serial Port I O Port Option Option v Telnet Send MAC Address T set SSH EE oro sup
7. MAC and IP address any hosts can t be reachable to it except for the hosts which have the allowed MAC and IP address Inactivate the option or check the setting is correct Checking the TCP status TCP is a protocol connected one to one without multiple connections function Because of this if a device is on a TCP connection other requests are denied If users are in this situation check the network status by connecting on TELNET or using ezManager dm Sollae Systems Co Ltd 58 http www ezTCP com wu CIE H10 User s Manual Ver 3 1 9 3 Communication Problem over Modbus TCP Checking Modbus TCP parameters Check all the related parameters that Unit ID Input Port Base Address Output Port Base Address Poll Interval and Notify Input change Checking which mode is using In case of MACRO or serialized Modbus TCP you can control the outputs of the CIE H10 Turn the mode off if those modes are using Contact us if you have any questions about above steps or our products gm Sollae Systems Co Ltd 59 http www ezTCP com wu CIE H10 User s Manual Ver 3 1 10 Technical Support Warranty and Precaution 10 1 Technical Support If you have any question regarding operation of the product visit Customer Support FAQ corner and the message board on Sollae Systems web site or send us an email at the following address E mail support eztcp com Website Address for
8. Mode COD TCP Client v Peer Address 10 1 0 2 2 Peer Port Local Port 1470 3 1470 lv TCP Serves 4 Event Byte Timeout zs Figure 6 3 setting the TCP server client mode Select the COD TCP Client mode Input an IP address and port number of a remote host Check the TCP Server check box Input the Local Port for waiting for the request segments of a TCP connection Set the Event Byte to value more than 1 byte Set the Timeout to proper value S2 Sollae Systems Co Ltd 35 http www ezTCP com CIE H10 User s Manual Ver 3 1 Fig 6 4 time chart for activating TCP Server option Table 6 6 descriptions of each state State H10 is waiting for request segments of a TCP connection The connection has been established H10 is on line and processes of the disconnection The connection has been terminated Both sides are offline Sends a request segment of a TCP connection The TCP Server Client mode only can be a useful option under condition of using Event Byte and Timeout Note that only one TCP connection can be established at the same time so users should consider setting Timeout properly For more details about the TCP Server Client mode please refer to the technical document on the Download Technical Documents page of our web site Souad Sollae Systems Co Ltd 36 http www ezTCP com CIE H10 User s M
9. a connection is established 512 or under 512 or under bytes are strongly recommended Timeout If there is no transmission of data for amount of time which is set to this parameter the CIE H10 tries to terminate the established TCP connection TCP Server This check option is enable the TCP server client mode In this mode the CIE H10 can be operated as a TCP server or client without changing its setting m Sollae Systems Co Ltd 33 http www ezTCP com w CIE H10 User s Manual Ver 3 1 DNS IP Address DNS IP Address needs when users use host name instead of the IP address on the Peer Port parameter 6 2 2 An Example An example of TCP client Figure 6 2 time chart for a situation that Event Byte is set to 0 Table 6 5 descriptions of each state State Before the power is supplied Sends request segments of a TCP connection right after it boots up Processes of the disconnection The connection has been established Data communication on both sides S2 Sollae Systems Co Ltd 34 http www ezTCP com CIE H10 User s Manual Ver 3 1 TCP Server Client mode In the TCP client mode the TCP Server check option is activated If you check this option the CIE H10 operates as the TCP server client mode In this mode the CIE H10 can establish a TCP connection both actively and passively without changing any setting M TCP IP D Communication
10. ap MAC Address Joo 20 ts or so as zl Ed Search Results 1 uud Local IP Address 0 1 0 1 Pe m AR Obtain an IP Automatically DHCP erent at a CR s0 s0 C Obtain an IP Automatically PPPoE PPPoE ID PPPoE Password Obtain DNE Server Address Automatically BERE Obtain an IP From The First Received Packet Use static IP address G Obtain an IP Automatically Local IP Address I Inm O Gateway IP pustpaddress o me v Advanced Menu Change F W HTML Debugging Message Import Variables Multi Write Windows Firewall Modbus TCP Set Password Factory Reset Export Variables PING ARP Select binding IP Figure 3 1 initial appearance of ezManager 3 1 1 Configuration via LAN Checklists Make sure of the connection between your PC and the CIE H10 via Ethernet If they are in the same network MAC Address search button can be used If they aren t only IP Address search is allowed to use Procedures 1 Searching Use Search All or Read button on ezManager 2 Selecting Select the MAC Address of your product 3 Setting Set the values of the parameters i Store the setting with the Write button Figure 3 2 procedures for configuration via LAN S2 Sollae Systems Co Ltd 19 http www ezTCP com CIE H10 User s Manual Ver 3 1 3 1 2 Configuration via Serial Checklists Make sure of the connection betwe
11. bps to 230 400 bps This port is for connecting users serial devices to Ethernet TCP IP including the Serialized Modbus TCP Pin Assignment Table 1 4 pin assignment of the RS232 port Ts eno crowned crowned reauire Ls ps Data set Ready sz input option Fees clear To sena rs232 input option SR Ring indicator nez inout NE NG Not Connected Data bits Parity and Stop bit Table 1 5 parameters of the RS232 port None Even Odd Mark Space Flow Control The CIE H10 supports RTS CTS and DTR DSR Hardware Flow Control Telnet COM Port Control Option The CIE H10 has Telnet COM Port Control Option function that is specified by RFC2217 It plays a role of an access server If the Telnet COM Port Control Option is enabled the CIE H10 sends the CTS DSR control signal to the communication counterpart and sets its serial port items RTS DTR Baud rate data bits parity stop bit after getting information from the communication counterpart dm Sollae Systems Co Ltd 11 http www ezTCP com w CIE H10 User s Manual Ver 3 1 1 5 4 Ethernet Interface An RJ45 connector is for the network interface of the CIE H10 You can use a UTP cable It automatically senses 10Mbits or 100Mbits Ethernet It also provides auto MDI MDIX function that can automatically sense 1 1 cable or cross over cable Each Ethernet device has its own hardware address The hardware address of the CI
12. configured by users For more details about the Modbus TCP protocol please refer to the document on the Download Technical Documents page of our web site 5 2 Serialized Modbus TCP Since 1 3A firmware serialized Modbus TCP mode had been added on the firmware In this mode the CIE H10 sends and receives Modbus TCP data via the serial port By using this mode you can monitor and control the I O ports of the CIE H10 through the RS232 port Note that if you are using this mode you can t control the output ports of the CIE H10 with HTTP or Modbus TCP And also the TCP and UDP data communication for serial devices cannot be activated dm Sollae Systems Co Ltd 26 http www ezTCP com wu CIE H10 User s Manual Ver 3 1 5 3 Macro Mode This mode let users set the values of the output ports with simple macros The CIE H10 reflects the values according to the macro expressions which are configured by users in advance It will be useful when users set the output values automatically from combinations of inputs Check Macro options on ezManager to activate this mode 5 3 1 Operator The algorithm used in the Macro mode is Boolean algebra In this case the AND OR NOT are used as operators Parenthesis may also be used The priority of operators is in the following order parenthesis NOT AND OR Each operator is represented by the following symbols Table 5 4 the operators Since calculations withi
13. ee 60 10 1Technical Support SR rnant 60 MOP WV EE AN a 60 LO PAD ROIO N EE N EN 60 10 22 Free Repair SerVices EEN 60 10 23 Charged Repair Services 60 103 ein lat let EE 61 jump 62 ZE Sollae Systems Co Ltd 4 http www ezTCP com wu CIE H10 User s Manual Ver 3 1 1 Introduction 1 1 Introduction In the era of Ubiquitous Environment many kinds of systems which use sensors like temperature humidity or pressure and controlling the power of remote devices have been developing The CIE H10 monitors those sensors and controls the remote devices It detects digital inputs from sensor s outputs and controls the relay outputs HTTP Modbus TCP serialized Modbus TCP and Macro mode can be used for these functions The CIE H10 can be used in another way because it equipped operation as a serial device server 1 2 Application Examples Remote I O device server network hub LAN CIE H10 Modbus TCP TTP digital output INTERNET Lights motors Modbus TCP digital r Fa wd switches remote host 1 remote host 2 Figure 1 1 remote I O device server S2 Sollae Systems Co Ltd 5 http www ezTCP com CIE H10 User s Manual Ver 3 1 Serialized Modbus TCP Lights motors digital Sensors switches digital input serial Modbus TCP
14. f Search All oe g MV Advanced Menu Change F W HTML Set Password Figure 8 3 setting debugging option Check the Debugging Message option Q Press the Write button After check the Advanced Menu click the Debugging Message button And then the debugging message window is shown on your screen like the figure below S2 Sollae Systems Co Ltd 53 http www ezTCP com CIE H10 User s Manual Ver 3 1 Wi Debugging Message Network Adapter 1 10 16 1 86 Intel 21140 Based PCI Fast Ethernet Adapter Ceneric 2 Packet Scheduler r c MAC Address Serial Port RS232 19200 NONE 8 1 NONE 4 BUFFE DROF el a er aar ees Log Close EE d Figure 8 4 debugging message window Pull down menu for selecting a network adapter Q Place for showing received debugging messages from the CIE H10 over the network Auto update to display the latest captured file on the screen of MAC Address Information of a selected message 6 Unavailable To start capturing debugging messages from the CIE H10 6 To stop capturing debugging messages from the CIE H10 Unavailable d Load Message is for loading a debugging log file to display Closing debugging message window 2 Sollae Systems Co Ltd 54 http www ezTCP com CIE H10 User s Manual Ver 3 1 8 3 Serial Port Tab Functions Networ Serial Port h
15. keep use the latest released firmware 7 1 2 Processes Downloading the latest released firmware Download the newest firmware file We update our homepage when a new firmware is released You can find it on our website Entering ISP mode Enter ISP mode to download firmware file to the CIE H10 Run a TFTP client and ready to send the F W file Run a TFTP client program ezManager is equipped the client program Click the Change F W HTML button Change F W HTML xj Figure 7 1 running TFTP client Check the Advanced Menu check box Click the Change F W HTML button to run TFTP client Select the Change Firmware radio button Input the IP address of the CIE H10 to the Local IP Address text box Press the Open Firmware HTML button and choose the firmware file S2 Sollae Systems Co Ltd 43 http www ezTCP com CIE H10 User s Manual Ver 3 1 Checking firmware file and Sending Change F W HTML x Lol Change Firmware C Ghana Local IP Address 115 200 bps 230 400 bps 460 800 bps EE Change F W HTML x Local IP Address Change Firmware Change HTML 80KB wm ma 115 200 bps 280 400 bps 460 800 bps ITTTTTTTTTTIIezrCP Manager v3 1H 2011 07 20 ES C Documents CL l Figure 7 2 sending firmware file Check if the name and path of the firmware file are correct Q Click the Send button Confirm the completed
16. message Souad Sollae Systems Co Ltd 44 http www ezTCP com CIE H10 User s Manual Ver 3 1 7 2 Changing Webpage 7 2 1 Webpage To monitor and control homepage should be uploaded in the CIE H10 7 2 2 Processes Making Users webpage or Downloading sample files Make your own webpage file or use sample webpage files which we ve been offering on our web site Entering ISP mode Enter ISP mode to send HTML files to the CIE H10 Running a TFTP client and ready to send the HTML files Run a TFTP client program ezManager is equipped the client program Click the Change F W HTML button Change F W HTML xj Local IP Address Set Password Factory Reset Figure 7 3 running TFTP client Check the Advanced Menu check box Click the Change F W HTML button to run TFTP client Select the Change HTML radio button Input the IP address of the CIE H10 to the Local IP Address text box 6 Press the Open Firmware HTML button and choose the HTML file 2 Sollae Systems Co Ltd 45 http www ezTCP com CIE H10 User s Manual Ver 3 1 Checking firmware file and Sending Change F W HTML Local IP Address E Change Firmware edm 2 pen Firmware HTML I8 4 1 0 a 2 C 115 200 bps 220 400 bps C 460 800 bps H ettings opicie SS Di Cie JPY Documents and Settings mhyun Desktop cie hl0_2011_07_07 favicon ico Documents and S
17. of your mouse Then you can show the properties of Internet Protocol TCP IP Press the Advanced button and add an IP Address like the figure below 2 xl IP address 10 1 0 2 Subnet mask 25 0 0 0 Add Cancel Add Figure 2 2 adding changing an IP address dm Sollae Systems Co Ltd 14 http www ezTCP com x A CIE H10 User s Manual Ver 3 1 Setting of the CIE H10 ezManager is the management tool for parameters of the CIE H10 This application is only for MS Windows and this is comfortable to use because it doesn t need installation process First search your CIE H10 via network All the values of parameters are set to the default values in the factory To apply it to your system proper values should be set via ezManager Default values of some major parameters are listed on the table below To do the following simple test keep these values without any changes Table 2 1 default values of some major parameters parameter value Local IP Address 10 1 0 1 Network Subnet Mask 255 0 0 0 Telnet Checked Option IP Address Search Checked Serial Type RS232 Baud Rate 19 200bps Parity NONE Data Bits 8 Serial Port Stop Bit 1 Flow NONE Communication Mode T2S TCP Server Local Port 1470 Web HTTP Checked Web HTTP Port 80 Modbus TCP Checked I O Port Master Slave Slave
18. size or doesn t have a buffer The range of the value could be from 0 to 25 and the unit is duration of sending 1 byte For example if you set this value to 5 each byte will be 2 Sollae Systems Co Ltd 55 http www ezTCP com CIE H10 User s Manual Ver 3 1 transferred with duration of sending 5 bytes 8 3 5 TCP Server Client mode 6 This mode is available on TCP client mode only In this mode you don t need to change the mode for switching active or passive TCP connection Note that the Event Byte option should be set to 1 or lager value SZ If you want to get more information about the above functions refer to the technical documents on the Download Technical documents page at our web site 8 4 Digital I O Functions 8 4 1 Valid Time The CIE H10 only recognizes signals of the input ports as the valid signals when the signal lasts for the Valid Time If the signals are not maintained during the Valid Time the input signals will be ignored The unit used for the Valid Time is 1ms However because the accuracy is only guaranteed in 10ms the designated values are rounded down in units of 10ms 8 4 2 Delay The CIE H10 gives output values to the output ports after the amount of time has set in the Delay If users set the value of Delay to 0 the CIE H10 gives the output value to the output port immediately The unit used for the Delay is 1ms However because the accuracy is only guaranteed i
19. 0 Port Option COMI Serial Port TCP IP Serial Type TTL Communication Mode rs 232 7 jz res TCP Server 7 Baudrate Peer Address 19200 Y Parity Peer Port Local Port nonz D fe 1470 TCP Serve Data Bits Event Byte s DI o Stop Bit WEE EES 1 bit Y d Flow Data Frame nonz Di Data Frame Interval lOms f DTR DSR Seperator Seperator Length Seperator HEX TX Interval O Seperator Operation Telnet COM Port Control RFC2217 2 Disable TCP Transmission Delay Create an ezVSP Port Figure 8 5 Serial Port Tab 8 3 1 TELNET COM port Control Option RFC 2217 This option is for sending and receiving serial port states between two devices Users can send and receive control signals such as RTS CTS when the states are changed 8 3 2 Disable TCP Transmission Delay 2 If you use this option CIE H10 sends the data from the serial port to Ethernet as quickly as possible 8 3 3 Data Frame Interval 3 Before sending data from the serial port to Ethernet ezTCP gathers data in the buffer If there is no data during the time which is configured in the Data Frame Interval ezTCP will send data to the network In case the value is set to 0 data will be sent immediately Please set this value to 11 or higher values for correct operation 8 3 4 TX interval This option is for preventing data loss in the case that the serial device has very small buffer
20. 8ports Remote I O Controller CIE H10 User s Manual Version 3 1 MODRUS HTTP OG Sollae Systems Co Ltd http www ezTCP com CIE H10 User s Manual Ver 3 1 To all residents of the European Union Important environmental information about this product This symbol on this unit or the package indicates that disposal of this unit after its mamma lifecycle could harm the environment Do not dispose of the unit as unsorted municipal waste it should be brought to a specialized company for recycling It is your responsibility to return this unit to your local recycling service Respect your local environmental regulation If in doubt contact your local waste disposal authorities gm Sollae Systems Co Ltd 1 http www ezTCP com wu CIE H10 User s Manual Ver 3 1 Bol dol 2 MEE Gon DIDI EE EE 5 LI STEW CUO EE 5 1 2 eet nl el 5 d EE 7 Als SDE CIT CALI E 8 141 HW specification EE 8 1442 S WspecllicatiOn EE OR EE staple Meuse used tod 8 Eet 9 L3 EE o 152 GEIER 10 RENE d11 154 Ethernet Intera oe 12 HAN EE EE EE EE EI ds E erer TER 13 RE 13 2 installation and Test iese seke ee Gee RE ge soge ee ee Ee oe ie Gee ee dni ee GE os 14 2 1 Le CIE le EE l4 214 Setting Network Aera RUE d Ee C a OE 44 2 2 Test le E 16 221 MOGDUSIGP EES 16 222 HTIP Test with a WEB bIOWSOF isse P Er i
21. E H10 is fixed in the factory before being shipped to the market The hardware address is also known as the MAC address 1 Tx Out 32 Tx Out 1 8 3 Rx In 6 Rx In Figure 1 9 the RJ45 connector 1 5 5 Power DC 5V is used for the power The specification of the power jack is as following 06 3 C0 9 69 Figure 1 10 the power specification Souad Sollae Systems Co Ltd 12 http www ezTCP com CIE H10 User s Manual Ver 3 1 1 5 6 System LED The CIE H10 has 21 lamps to show the current system status Each lamp shows the following status Table 1 6 status of the system LED owr rea on suppyino he power connected with 100M bit network Common Rd ou connected with 10M bit network blinks every assigned an IP address second blinks 4 times without being assigned an IP STS Yellow Normal at once address by DHCP or PPPoE mode establishing a Modbus TCP EE Serial blinks operating for the serial configuration Configuration simultaneously mode mode TXD ISP mode operating for the ISP mode 1 5 7 ISP Switch There is an ISP switch located on the side of the product It is a switch that will allow the CIE H10 to be operated as serial configuration mode or ISP mode If the switch is pressed between 20ms and 1s the CIE H10 changes the mode into the serial configuration mode In this mode you can configure the environme
22. S Directive Network 1 4 2 S W specification TCP UDP IP ICMP ARP DHCP DNS lookup DDNS Telnet COM Port Control Option RFC2217 Modbus TCP HTTP Protocol Diagnose Online Debugging Function Operation F W upgrade mode Serial A Configuration with the RS232 port Configuration Modbus TCP Slave Master Passive Active EC I O server Web Browser HTTP Macro Stand alone Serialized Communicati Modbus TCP on Mode Serial devices TCP Server Client AT emulation UDP server Configuration program via LAN Programs ModMap Modbus TCP Application for Windows MI Sollae systems Co Ltd is http www ezTCP com x i CIE H10 User s Manual Ver 3 1 1 5 Interface 1 5 1 Input Ports Because each of the CIE H10 s input ports are isolated by photo couplers users don t need to be worried about the polarity The circuit of the input port is shown in the figure below The EXTERNAL INPUT1 and EXTERNAL INPUT2 port should be interfaced with the user device 3 3V 10K 1K 1 4W EXTERNAL INPUT 1 gt gt gt TO PROCESSOR EXTERNAL INPUT 2 gt 1K 1 4W Figure 1 7 a circuit of the input port The voltage specification of the input port is as follows Table 1 1 the voltage specification of the input ports Max Input Voltage DC24V NE was 3 fo The input port is interfaced with a 5mm terminal block Thus use a shaped screwdriver to connect it with the user device T
23. alized CIE H10 communicates through the RS232 port using the data Modbus TCP format of Modbus TCP M Users can automatically control the output ports by setting MACRO acro using some basic formula of Boolean Algebra WEB HTTP Users can monitor and control the CIE H10 via HTTP serial Ethernet converter The CIE H10 can be used as a serial Ethernet converter There are four communication modes in this operation Table 4 3 comparison of four communication modes modifying i serial name protocol connection software of topology i g configuration serial devices TCP Sewer Not available MI Sollae Systems Co Ltd E http www ezTCP com wer CIE H10 User s Manual Ver 3 1 5 Methods for I O control 5 1 MODBUS TCP The CIE H10 supports Modbus TCP By using this protocol it remotely monitors and controls I O devices To use this method users application should support this protocol 5 1 1 Related Parameters Table 5 1 Modbus TCP related parameters Input Port Base Initial address of the input ports Address Output Port Base Initial address of the output ports Address Passive Connection waiting for accepting a Modbus TCP connection Active Connection requesting a Modbus TCP connection Multiple Connection The numbers for multiple Modbus TCP connections Control Method of Control method for the output ports of the slave Single FC XX Multiple Control Method of Control method for the ou
24. also word unit at once e FC 16 Multiple CIE H10 controls the output ports and monitors the input ports of slaves with WORD unit by FC16 write multiple register and FC 03 read multiple register e FC 05 Single CIE H10 controls the output ports and monitors the input ports of slaves with BIT unit by FCO5 write coil and FCO2 read input discretes Sollae Systems Co Ltd 25 http www ezTCP com CIE H10 User s Manual Ver 3 1 5 1 4 TCP Connection Modes In the standard of Modbus TCP the master program should make a connection to the slave using port number 502 However sometimes Modbus TCP devices should try connecting to the master actively For this case the CIE H10 supports the active connection mode Table 5 3 the passive active connection The standard Modbus TCP passive Remote host connects to the CIE H10 connection Port number that is used for communication must be designated The CIE H10 tries to establish a connection to the remote host The active The IP address or host name and port number of the remote connection host is required 5 1 5 Initial Output Value The initial value of the CIE H10 s output port can be configured Depending on the value of Initial State at the boot time output ports are set to ON or OFF 5 1 6 Write Pulse By using the function code 105 you can give the signal of pulse type to the output ports This means the output signal is kept during specified time
25. anual Ver 3 1 6 3 AT Command AT command is a mode which users control the CIE H10 with AT command like controlling modem In this mode active and passive TCP connections are available And users are allowed to configure some environmental parameters with extended commands 6 3 1 Key parameters The configuration should be implemented via the serial port of H10 Table 6 7 some of extended commands for configuration Commands Description Examples PLIP Local IP Address AT PLIP 10 1 0 1 lt CR gt PLP Local Port AT PLP 1470 lt CR gt PRIP Peer IP Address AT PRIP 10 1 0 2 lt CR gt PRP Peer Port AT PRP 1470 lt CR gt PDC DHCP AT PDC 1 ON lt CR gt PTO Timeout AT PTO 10 lt CR gt PWP Store setting AT PWP lt CR gt Related items with the IP Address and Local Port As well as the local port the IP address related parameters such as IP Address Subnet Mask and Gateway IP Address can be set Peer Address Peer Port IP address and local port of a remote host are can be set Type of assigning the IP address Manual DHCP PPPoE Not only manual setting also automatic assigning protocol DHCP PPPoE is available The others Some of options including Timeout can be configured in this mode Zen Sollae Systems Co Ltd wu 37 http www ezTCP com CIE H10 User s Manual Ver 3 1 6 3 2 Examples TCP Ser
26. as been changed 2011 08 09 2011 12 14 2012 02 08 2012 05 23 2012 06 25 2013 02 07 O Descriptions of TCP Server Client mode has been modified O Descriptions of DynDNS service has been changed Tm my Kim O Descriptions of FIFO function has been deleted i O Add recommended values of the Event Byte l Amy Kim O Download link and Typo have been fixed O A picture of the default web server has been updated now my Kim Extend the warranty period to two years i O Change description of network interface E Amy Kim Remove description about PPPoE and DHCP Change voltage conditions of output port Amy Kim dm Sollae Systems Co Ltd 63 http www ezTCP com wu
27. block units Therefore data that comes through the CIE H10 s serial port must be classified in block units to be sent elsewhere 6 4 1 Key parameters Block Size Byte Block Size means the size of a block in UDP mode Its unit is byte The size of bytes are come into the serial port the CIE H10 sends them as one block to the network The maximum value could be 1460 bytes Data Frame Interval Data Frame Interval means the time for gathering data to make one block Its unit is 10ms If there is no transmission during the time which is set to this value the CIE H10 sends gathered data in the buffer as one block to the network Once one of the parameters is sufficient the block size is decided as the condition Dynamic update of Peer host If users set the value of Peer Address and Peer Port to 0 dynamic update of peer host function is activated By using this function the CIE H10 can communicate with multiple hosts without additional setting gm Sollae Systems Co Ltd 40 http www ezTCP com wu CIE H10 User s Manual Ver 3 1 6 4 2 Examples Block Size 5 bytes Data Frame Interval 1s 100 10ms i remote ho serial devices Figure 6 7 time chart for block size is 5 bytes and Data Frame Interval is 1s Table 6 10 descriptions of each state State H10 is receiving data from the serial port H10 Sends 5 bytes as one block based on the Block Size Serial device sends data 678
28. d Do not use the product in an extremely cold or hot place or in a place where vibration is severe Do not use the product in an environment in which humidity is high or a lot of oil exists Do not use the product where there is caustic or combustible gas Sollae Systems does not guarantee normal operation of the product under the conditions a lot of noise exists Do not use the product for a purpose that requires exceptional quality and reliability relating to user s injuries or accidents aerospace aviation health care nuclear power transportation and safety purposes Sollae Systems is not responsible for any accident or damage occurring while using the product dm Sollae Systems Co Ltd 61 http www ezTCP com wu CIE H10 User s Manual Ver 3 1 11 History CS 2008 01 10 O Modify Digital Input Interface s Drawing Change Images Modify ATC description 2008 05 28 O Add IP Change Trap HTTP Port Number 2008 08 06 18 Serial Parity MARK SPACE add O Add description of Serialized Modbus TCP O Add description of Users Web Page O Add contents of new ezManager O Add the description of serial configuration mode Add the description of U2S echo function Modify the table of System LED 2009 06 18 2 0 l Modify most of the figures Change the form of document Change the home page link of Technical support Reduce the contents about ezManager Remove the ATC chapter C
29. e PiPlPlPlololojo PIPJoOl ol HIiFPIlolo plolslolslolslo nlalalalalslolo o lololelololol lo ZE Sollae Systems Co Ltd 28 http www ezTCP com w CIE H10 User s Manual Ver 3 1 5 4 Web HTTP After starting the web browser type the CIE H10 s IP address after typing http in the address window to connect to the CIE H10 If passwords for the CIE H10 are designated the following window will be popped up Connect to 10 1 0 1 Figure 5 1 authentication with password the CIE H10 does not care the User name You don t have to fill the box Q Password should be the same with password which is set through the ezManager 5 4 1 Changing port number for HTTP In case you cannot use the port number 80 default port number for HTTP because the ISP Internet Service Provider blocks the port you can change that port number v Web HTTP Web HTTP Port 8080 Size of Web HTTP Page S0KB e Le http 10 1 0 1 8080 Figure 5 2 changing port number for HTTP Input a port number to the Web HTTP Port box Input the IP address of the CIE H10 with changed port number and http Souad Sollae Systems Co Ltd 29 http www ezTCP com CIE H10 User s Manual Ver 3 1 5 4 2 Uploading Users Web Page 1 3A or subsequent versions of firmware support uploading custom web page This function is available to anyone who can make HTML files If yo
30. earch All 1 Write Status Simple Test V Advanced Menu 3 4 Import Variables Multi Write Windows Firewall Modbus TCP Set Password Factory Reset Export Variables PING ARP Select binding IP Stop Change F W HTML Debugging Message Figure 2 3 Modbus TCP test program of the ezManager Search connected the CIE H10 with Search All button Select a MAC address of searched product on the search result Check the Advanced Menu option Press the Modbus TCP button 6 The test program will appear on the right side of the ezManager me In the case of using previous versions of firmware than 3 1F the test program is shown automatically when you success in searching the product Sut Sollae Systems Co Ltd 16 http www ezTCP com CIE H10 User s Manual Ver 3 1 Modbus TCP test Ri Modbus TCP xj I O Port Wi Modbus TCP X 1 0 Port 34 Dio Dod Dil TCP IP Connection Peer Address 10 1 0 1 Peer Port 502 1 a oi Lee COM Port COM Port con 7 Los 7 Gpen Close Read Poll Interval Start 1000 ms Stop Start Figure 2 4 Modbus TCP test Input the IP address of the CIE H10 Input the local port for Modbus TCP of the CIE H10 Ina local area network D and 2 steps can be omitted Try to connect by pressing Connect button Under the connection chec
31. een established Data communication on both sides S2 Sollae Systems Co Ltd 32 http www ezTCP com CIE H10 User s Manual Ver 3 1 6 2 TCP Client In this mode the CIE H10 functions as a TCP client The CIE H10 sends request segments to a remote host with information of Peer Address and Peer Port Under situation that the TCP server works fine with the specific port the connection will be established After then the CIE H10 converts the raw data from the serial port to TCP IP data and sends them to the network and vice versa 6 2 1 Key parameters Peer Address This item should be an address of a remote host who is waiting requests of a TCP connection Peer Port Peer Port should be the port number which is designated by the remote host Event Byte The CIE H10 decides the time to send request segments for the TCP connection with this parameter Table 6 3 the operation of Event Byte 1 Description CIE H10 sends a request segment of the TCP connection right after it boots up Otherwise CIE H10 sends the segment right after it received amount of data 512 or under which is set to the Event Byte from the serial port In addition users can handle the serial data before a TCP connection is established with this parameter Table 6 4 the operation of Event Byte 2 Value Description 0 CIE H10 doesn t send the data Otherwise CIE H10 sends the data right after
32. en your PC and the CIE H10 using a RS232 cross cable The CIE H10 has to be operating in the Serial Configuration mode You make the CIE H10 operates in the serial configuration mode by pressing the ISP button less than 1 second After then read the setting on the Serial tab 1 Switching modes Change the mode to the serial configuration mode 2 Reading Read the stored setting by pressing the Read button 3 Setting Set the values of the parameters e UV x O e oO c A D Lo Store the setting with the Write button Figure 3 3 procedures for configuration via serial port Step 2 Reading Search ezTCP r Search ezTCP pc xp DO mc IP Serial COM Port COM Port omp demo LES ss doe cepe fe Led Figure 3 4 reading procedure via serial Choose the Serial tab Select the COM port which is the device is connected 3 Open the COM port pressing the Open button Load the setting with the Read button If you want to know more specific manners of setting please refer to the document ezManager Users Manual on the Download gt gt Technical Documents page of our website S2 Sollae Systems Co Ltd 20 http www ezTCP com CIE H10 User s Manual Ver 3 1 3 2 AT command In the AT command mode you can change some parameters through the serial port Checklists Make sure of the connection between your PC and the CIE H10 us
33. ettings mhyuniDesktop cie hl0 2011 07 07 hl0 g off jpg and Set ROEDER ES and Set and Set Local IP Address C Change Firmware Change HTML 80KB Set 10 1 0 Open Firmware HTML Send Close C 115 200 bps 230 400 bps 460 800 bps TT H e2TCP Manager v3 1H 201 1 07 20 x C Document C Document C Document Figure 7 4 sending firmware file Check if the name and path of the firmware file are correct Q Click the Send button Confirm the completed message Souad Sollae Systems Co Ltd 46 http www ezTCP com CIE H10 User s Manual Ver 3 1 7 3 Status Monitoring 7 3 1 Using TELNET Once the TELNET option is activated users can remotely log in to the CIE H10 If a password is set users should input the password After then messages from the CIE H10 appear like the figure below CIE H10 Management Console v1 3E Sollae Systems Ep Figure 7 5 log in to the CIE H10 on TELNET You can check multiple states with the following commands Table 7 1 commands for checking states command option description usage net Network Status Ish st net sio Serial Port Status Ish st sio uptime System Uptime Ish gt st uptime OP1 OP2 Session Control Ish gt sc com1 close OP1 OP2 st net Capturing Serial Data Ish gt sd 1 100 st net command displays present network states of all sessions Ish st
34. ing a RS232 cross cable All the parameters of the serial port between the CIE H10 and the Terminal of your PC should be the same In the AT command mode you can change some parameters through the serial port TCP IP Communication Mode Peer Address Peer Port 0 Local Port 1470 mi TCP Server Figure 3 5 setting the communication mode to the AT command Procedures 1 Configuring modes Set the communication mode to the AT command 2 Running Terminal Run a serial terminal program Ex HyperTerminal 3 Setting Set the values of the parameters using AT commands I Store the setting with the AT PWP command Figure 3 6 procedures for configuration with AT command Table 3 1 parameters which are available to change with AT command Division Available parameters Local IP Address DHCP PPPoE Subnet Mask Gateway IP Address DNS IP Address Local Port Peer Address IP Address or Host name Peer Port IP Address related items A TCP connection related items Option ESC code sending option timeout Including above items rest of parameters can be set by ezManager a Sollae Systems Co Ltd 21 http www ezTCP com wu CIE H10 User s Manual Ver 3 1 4 Operation Modes 4 1 What is the Operation Mode Fach of three operation modes are designed for specific purposes and those are as follows Normal mode This mode is for normal data communication and ha
35. ion in the status window the status is automatically updated in every second LEFT ij x Status FIRMWARE VERSION CIE H10 1 4 Rev B SYSTEM UPTIME D days 00 00 03 45 P4 NETWORK NEOPMA ON MAC Address 00 30 9 07 80 15 Device IP address 10 1 0 1 Subnet mask 255 0 0 0 Gateway 0 0 0 0 Name Server 0 0 0 0 P STATE COM1 LISTEN MODBUS EN SERIAL STATUS COMI sio rx O0 net tx 0 net rx 0 Sio tx 0 V IO PORT STATUS IN 000000200 OUT 00000000 J RP TABLE TCP IP Connection LISTEN 23 LISTEN 80 LISTEN 80 LISTEN 80 Refresh Every 1 Second Figure 7 11 status window of ezManager FIRMWARE VERSION The name of model name and the version of firmware are displayed here SYSTEM UPTIME Amount of time is displayed since the CIE H10 boots up e IP4 NETWORK INFORMATION All information about related items with IP Address including the MAC address is shown here It works even if the IP address is assigned from DHCP or PPPoE S2 Sollae Systems Co Ltd 49 http www ezTCP com CIE H10 User s Manual Ver 3 1 TCP STATE TCP status of each port is shown in this section Table 7 2 TCP STATE Message Description LISTEN waiting for requests of a TCP connection CLOSE a TCP connection is closed SYN_SENT send SYN segment to make a TCP connection ESTABLISHED When a TCP connection is establ
36. ished N A In UDP mode SERIAL STATUS Amount of data in every buffer is displayed The unit is byte Table 7 3 SERIAL STATUS Buffer Description sio rx The number of data which is received from the COM port net tx The number of data which is sent to the remote host net rx The number of data which is received from the remote host sio tx The number of data which is sent to the COM port LO PORT STATUS This represents I O ports status 1 means HIGH ON and 0 means LOW OFF ARP TABLE This part shows ARP table on the CIE H10 When a TCP connection is established or UDP data communication is performed the information of IP and MAC address is automatically stored in the ARP table This information is held for 1 minute When 50 seconds is passed the CIE H10 starts broadcasting the ARP packet again If there is no response until the time is 0 the information is removed If there is a response the time is updated 60 seconds again TCP IP Connection In this section the same information with TCP STATE is displayed with IP address and port number A difference is that users can terminate a TCP connection When right click on a session a small pop up window is created Password This text box is activated when the CIE H10 has a password If users want to close the TCP connection this password has to be correctly filled Refresh Every 1 Second If this option is checked e
37. k if the Di LEDs are turned on or off with signal input Check if Do LEDs are turned on or off with clicking the LEDs Click the Disconnect button after the test is completed Souad Sollae Systems Co Ltd 17 http www ezTCP com CIE H10 User s Manual Ver 3 1 2 2 2 HTTP Test with a WEB browser This is for testing the operation of Input and output ports of the CIE H10 via HTTP The test was implemented with a WEB browser You can use WEB browsers such as MS Internet Explorer Google Chrome and Mozilla Firefox sl Ele Edt view Favorites Tools Help Ld Le ux Cp Back ED x IE T JO search Se Favorites EP media 63 CIE H10 Sollae Systems RELAY OUTPUT Doo UNE MED OMS Eo Figure 2 5 HTTP test Input the IP address of your CIE H10 on the address field Ex 10 1 0 1 Check if the DI LEDs are turned on or off with HIGH signal Check if DO LEDs are turned on or off with clicking the each of LEDs Press the Reload button to update the status S2 Sollae Systems Co Ltd 18 http www ezTCP com CIE H10 User s Manual Ver 3 1 3 Configuration 3 1 Configuration with ezManager Wi ezTCP Manager v3 1K 2012 05 31 10 1 0 100 Intel 21140 Based PCI Fast Ethernet Adapter Generic 42 Packet Scheduler Minipont Search estep Netvork serial Port 1 0 Pore option mc rp sean Product kee ver 3
38. lae Systems Co Ltd 57 http www ezTCP com CIE H10 User s Manual Ver 3 1 9 2 Connection Problem over Modbus TCP Checking parameters related with TCP IP When the CIE H10 has a private network IP address personal computer s IP address has to be the same sub network Check if the IP address and local port number are correct In case of a fixed IP address the subnet mask gateway IP address and DNS IP address should be configured Table 9 1 major parameters related with Modbus TCP Slave or Master Local IP Address the connection mode Active Passive Peer Address and Peer Port Subnet Mask Gateway IP Address DNS IP Address DDNS option and etc PING Test Confirm the connection over the network by PING test If the CIE H10 doesn t send any reply from the request check the network environment e Firewall In case the networks which need strong security the access may be denied by their firewall Under this circumstance users should ask the person in charge of their network to release ports which will be used Ex TCP 502 UDP 50005 Operation Mode A TCP connection is not possible when the CIE H10 is operating in the ISP or Serial Configuration mode Connection Mode To make a TCP connection both a server passive mode and a client active mode should exist If there are only servers or clients The TCP connection can t be established ezICP Firewall When users set the ezTCP firewall with
39. n 10ms the designated values are rounded down in units of 10ms Tf the timer for the Delay is already running all the subsequent orders for giving signals to the output ports are ignored gm Sollae Systems Co Ltd 56 http www ezTCP com wu CIE H10 User s Manual Ver 3 1 9 Self Test in Trouble When users are in trouble with the CIE H10 make sure of the following steps first 9 1 Searching problem with ezManager Confirming types of configuration utility The CIE H10 can be configured by ezManager Cancelling the Firewall operation In case of being blocked by firewalls of personal computer or network block you must cancel all the firewalls before searching the CIE H10 Most of vaccine programs have firewall functions so it can cause some trouble to search the CIE H10 Close or pause these programs before searching the products Stable supply of the power Check if the power is supplied continually The red LED on the body shows that the power is switched on Connection with the network Make sure that the network connection is fine including Ethernet cable In this step we recommend that users connect the CIE H10 with PC directly or in the same network hub Checking options of restriction In case that restriction of access is activated the communication with ezManager will be unavailable When users are in this situation make the CIE H10 operate in ISP mode 2 Sol
40. n the parenthesis have the Parenthesis highest priority they will be calculated first Parenthesis may be nested used Operand that follows NOT operator is toggled If NOT operand is 0 it will be changed to 1 If it is 1 it will be changed to 0 If Operand values that surrounds AND operator AND all 1 the result value will be 1 If either one of them is 0 the result will be O as well If Operand values that surrounds AND operator all 0 the result value will be 0 If either one of them is 1 the result will be 1 5 3 2 Operand Operands used in macro mode are each input port Each input port is designated with i0 i7 symbol based on their sequence Since capital letters are not recognized they can also be written as IO I7 The output ports couldn t be used as an operand dm Sollae Systems Co Ltd 27 http www ezTCP com wu CIE H10 User s Manual Ver 3 1 5 3 3 Expression example Here are some examples In the expressions spaces between the two operands will be ignored Table 5 5 an example of equation oi Perform OR for iO and i1 10 Spaces in between two operands may be ignored Perform NOT with value from performing OR for i1 Do2 iO i1 i7 and i7 Then perform AND with that value and iO Based on input values from three input ports the output values are as follows Table 5 6 the logic table of the table 5 5 Input port value Output port value H Do0 Do2
41. net proto name http3 http2 httpl http modbus 2 Sollae Systems Co Ltd local address Figure 7 6 st net command 47 peer address 10 16 0 56 3076 0 senda state 140 ESTABLISHED 0 LISTEN 0 LISTEN 0 LISTEN 0 LISTEN 0 LISTEN 0 LISTEN http www ezTCP com CIE H10 User s Manual Ver 3 1 st sio st sio command displays the number of bytes for the serial port Ish gt st sio port fmax rbmax rxbuf txbuf rx count tx count Figure 7 7 st sio command st uptime st uptime command shows amount of time since H10 has booted up Ish gt st uptime 00 04 21 79 up 0 days Era Figure 7 8 st uptime command sc sc command is used when users close a session OP1 means the name of session and OP2 should be CLOSE Ish gt sc com close com closed sh gt Figure 7 9 sc command Jn the case of the sc command you should use only small letters e sd sd command is for capturing serial data OP1 means name of the session OP2 means period which has a 10ms unit for the capture 100 coml dump buffering time 1000ms eh re lt 61 73 txl 69 66 if Figure 7 10 sd command Souad Sollae Systems Co Ltd 48 http www ezTCP com CIE H10 User s Manual Ver 3 1 7 3 2 Using ezManager Status of the CIE H10 can be monitored by Status button on ezManager By using the Refresh Every 1 Second opt
42. nt parameters through the RS232 port If the button is pressed over a second or the power is supplied when you are pressing the button the CIE H10 is operated as ISP mode CIE H10 Figure 1 11 ISP switch In the ISP and Serial Configuration mode the designed password and access restriction could be restored or reset Use these modes when you are faced with the problems m Sollae Systems Co Ltd 13 http www ezTCP com wu CIE H10 User s Manual Ver 3 1 2 Installation and Test 2 1 Installation Let s look into the operation of the CIE H10 Basically the set of input ports and output ports are independently used Thus you can use the input ports only or the output ports only On the other hand you can also correlatively use those ports by using the MACRO mode on the output ports Before testing the CIE H10 you should connect the Ethernet port to a PC It will be no problem that the Ethernet connection is established through network hubs e RJ45 LAN RJ45 Figure 2 1 the connection between H10 and a PC 2 1 1 Setting Network Aera This step is for setting both the CIE H10 and your PC to be located the same network If only they are the TCP connection between them can be established Setting of the PC Add or change the IP address of the network adapter on your PC Get into the menu of Windows Control Panel Network Connections Properties of the Network Adapter with right click
43. orrect some expressions O The style of document has been changed O Application Diagrams have been added O Operating Storage temperature have been added O The form of history has been modified 2009 12 02 2 1 O Most of figures have been updated O Description of sc command has been modified O Maximum value of Event byte has been added O Description of Sending MAC Address and RFC2217 option have been modified 2009 12 14 O The table 4 1 has been changed Roy LEE AP Sollae Systems Co Ltd E http www ezTCP com er 2 5 0 d 2 3 14 15 1 6 17 18 CIE H10 User s Manual Ver 3 1 2010 08 30 2011 01 20 2011 08 01 O The description of the CIE H10 has been changed GEWEER o O Major icons have been inserted on the front cover d O Descriptions about input output ports have been added O Diagram of Macro mode has been added O The name of caption for figures is changed O Some expressions have been corrected or modified O A caution has been added about using MACRO O A figure of location of the ISP switch has been added O Pictures of the configuration tool have been updated 2 5 O A picture of the default web server has been updated O Descriptions about the new functions have been added FC 05 Multiple connections write pulse and etc O Chapter 8 has been reconstructed O The link for the support page has been corrected Maximum value of Event Byte has been corrected O Figure 4 1 h
44. s 5 different communication modes Configuring parameters is also available in this mode Serial configuration mode This mode is for configuring environmental parameters through the RS 232 port ISP mode This mode is for upgrading firmware In addition you can set environmental parameters even though the security options are activated and you can also reset the security options 4 2 How to chage the mode to another Initial state Reser OP Put e Press the ISP button over 1 second e Configuration mode Figure 4 1 how to initiate each operation mode S2 Sollae Systems Co Ltd 22 http www ezTCP com CIE H10 User s Manual Ver 3 1 4 3 Comparison of the each mode The following table shows summaries of the each mode Table 4 1 comparison of the each mode name entering serial port Configured Normal Supply the power value Serial Press the ISP button shortly between 10ms and 1s 115200 N 8 1 Configuration Supply the power with pressing the ISP button or ISP pest SE E 115200 N 8 1 press the ISP button over 1 sec in other modes 4 4 Normal Mode In normal mode there are four types of ways to monitor and control I O and of additional operations as a serial Ethernet converter 1 0 controller Table 4 2 digital I O control types description Control and monitor the I O of the CIE H10 via Modbus TCP Modbus TCP It supports both master and slave mode Seri
45. se Systems Co Ltd Em http www ezTCP com y i CIE H10 User s Manual Ver 3 1 8 2 Option Tab Functions 8 2 1 Notify IP Change The CIE H10 can be a TCP server even though it is assigned the IP address automatically Using Notify IP Change function it sends its IP address with the host name to the specific server There are 3 types DDNS TCP and UDP of functions provided Dynamic Domain Name Service DDNS The CIE H10 supports DDNS function offered by DynDNS to manage its changed IP address as a host name Therefore you have to make an account and create host names on the website of DynDNS before use this All about service usage of an account could be changed according to the policy of DynDNS Homepage of DynDNS http dyn com dns r Notify IP Change Protocol Interval DNS dyndns o 40320 Minute s 8 9 2 Port DDNS ID DDNS Password amp ccounc ee eee e a Host Name dyndns rournostnane dyndns orgq E 6 Figure 8 1 setting DDNS Select the DDNS dyndns org item 40 320 is a fixed value Input the ID of DDNS account Input the password of the account Input one of the host names which you created on your account e TCP UDP In case you have an own server and want to manage the information about changed IP addresses you are allowed to use TCP UDP for using this option The Data Type can be selected as ASCII or hexadecimal and the
46. tput ports of the master AND OR AND OR Peer Address Peer s IP address when the CIE H10 performs active connections Peer Port Active Peer s local port when the CIE H10 performs active connections Input Change A function for immediate notification with changing the IP Notification address Macro Applying macro function on the output port Initial State Output port value when the CIE H10 boots up The difference between the values of Input port base address and Output port base address should be at least 8 MI Sollae systems Co Ltd E http www ezTCP com x 2 CIE H10 User s Manual Ver 3 1 5 1 2 Modbus TCP Slave Mode According to the standard Modbus TCP users can use a Modbus TCP manager to control and monitor their I O devices Like this standard you can set the CIE H10 to the Slave item to Slave mode The Passive connection would be better than the Active in this mode and the Peer Port should be 502 Table 5 2 values for standard Modbus TCP TCP Port 502 Configure the proper values of Unit ID Input Port Base Address and Output Port Base Address 5 1 3 Modbus TCP Master Mode In this mode the CIE H10 operates as a Modbus TCP master As a master the CIE H10 sends queries which read the values of the input ports and which change the values of the output ports to the Modbus TCP slave devices At this time the CIE H10 controls the output ports with not only bit unit individually but
47. tus Monitoring ENEE 434 Using TELNET urne sp Sollae Systems Co Ltd EA wu Mn 27 AE OG 29 http www ezTCP com CIE H10 User s Manual Ver 3 1 3 2 Using EE I E 49 8 Additional FunctiONnS sissies ese lie esse soes gegil Ge poo toes tro Peine eee N sede ee ge REGERE ge Ee Donee ES Ee UR 51 Ul SSS lu E 51 8 1 1 Restriction of Access ezTCP Firewall ee ee Ee ER 5 812 Setting D ser 51 8 2 Option Tab Functions ENEE 52 821 Notify IP Change 52 822 Sending MAC Address eher 53 623 Debugging Message d e pb rt rettet itte ce reed eet taies 53 8 3 Serial Port Tab FunctiONS sessie Ses ER SEER aa EA iie AEA 55 8 3 1 TELNET COM port Control Option RFC 2217 D 55 8 3 2 Disable TCP Transmission Delay i e 55 833 Data Frame Interval use se ese se ee ee ee ee ee ee ee ee ee ee ee ee 55 BB EE 55 835 TCP Server Client mode vescsscessescvessesssecsessesssecsesssssessessusssessessusssessussuscsessessuccsessussuecsessacssecees 56 84 Digital 1 Oe dele rct 56 SAL VINA E 56 de Eet 56 EET OUI OE EE vasaris ressas is ussas iess visza 57 9 1 Searching problem with ezMangger ENEE 57 9 2 Connection Problem over Modbus ch ee ee ee ene RR ee ee RR RR RR ee 58 9 3 Communication Problem over Modbus Ch teen eek Rea 59 10 Technical Support Warranty and Precaution se see ee ee ee Ge ee Ge Ge ee
48. u get some simple syntax it is possible to monitor and control the I O ports with your homepage interface Upgrading Boot and Firmware To use this function it is needed for users who have been using 1 5 version of boot and 1C version of firmware or lower versions If you have already got the updated products you don t need this process en LAN CIE H10 Read 0101234567 CIE H10 CIE HIO 0001234567 Solise Systems Q o OSOOOOODODD Sollae Systems CIE H10 On S Figure 5 3 examples of web page Default image Q Default text No comment Sample01 6 Sample02 Simple image Simple text f you cannot use this function you should upgrade the version of boot even though your CIE H10 has the latest version of F W For more information about the upgrading boot please refer to the CIE H10 upgrading Boot and F W document on the Download gt gt Technical Documents page sm Sollae Systems Co Ltd 30 http www ezTCP com wu CIE H10 User s Manual Ver 3 1 6 Communication Modes The CIE H10 provides RS232 lt TCP IP conversion function along with input output port monitoring and controlling function 6 1 TCP Server In this mode the CIE H10 functions as a TCP server The CIE H10 waits for a TCP connection from remote hosts Once a host tries to connect to the CIE H10 it responses to that request After the connection is established the CIE H10 converts the ra
49. ver setting parameters and a passive connection remote ho Figure 6 5 a passive TCP connection Table 6 8 descriptions of each state Point State Set parameters in the AT command mode H10 waits request segments of a TCP connection with the ATA command H10 is waiting for requests of a TCP connection A remote host has sent SYN segment to H10 Processes of the TCP connection TCP connection has been established The CIE H10 sends CONNECT message to the serial port Most of the response messages from the serial port of the CIE H10 are omitted on above figure Souad Sollae Systems Co Ltd 38 http www ezTCP com CIE H10 User s Manual Ver 3 1 TCP Client setting parameters and an active connection Figure 6 6 an active TCP connection Table 6 9 descriptions of each state State Set parameters in the AT command mode H10 sends a reguest segment of a TCP connection with the ATD command Processes of the TCP connection The TCP connection has been established The CIE H10 sends CONNECT message to the serial port A For more information about this please refer to the ATC mode on the Download gt gt Technical Documents menu of our web site Souad Sollae Systems Co Ltd 39 http www ezTCP com CIE H10 User s Manual Ver 3 1 6 4 UDP UDP has no processes of a connection In this mode data is sent in
50. w data from the serial port to TCP IP packets and sends the packets to the network and vice versa 6 1 1 Key parameters local Port This is a server s port number which is used in the TCP connection Event Byte With setting event bytes users can handle the serial data before a TCP connection is established Table 6 1 Event Byte Value Description 0 CIE H10 doesn t send the data Otherwise CIE H10 sends the data right after a connection is established 512 or under 512 or under bytes are strongly recommended Timeout If there is no transmission of data for amount of time which is set to this parameter the CIE H10 tries to terminate established a TCP connection Notify IP Change This function is for notifying information about changed IP address to a server Not only the TCP UDP protocol but Dynamic Domain Name Service DDNS can be used Restriction of Access ezTCP Firewall Users can block TCP connections from unauthorized hosts by using this option Both IP and MAC address are available MI cose Systems Co Ltd 31 http www ezTCP com ECH y i CIE H10 User s Manual Ver 3 1 6 1 2 An Example An example as a TCP server Figure 6 1 TCP server Table 6 2 descriptions of each state State H10 is waiting for request segments of a TCP connection Remote host has sent a request SYN segment Processes of the connection The connection has b
51. ypes for giving input The type of the input ports is the wet contact by photo couplers This type needs two wires which have difference of voltage level for making an input signal However there is an accessory which changes the input type to dry contact By using this accessory you can give an input signal ON or HIGH with switch relay interface The input ports are designed only for monitoring signals dm Sollae Systems Co Ltd 9 http www ezTCP com wu CIE H10 User s Manual Ver 3 1 1 5 2 Output Ports The output ports of the CIE H10 are interfaced to relays as shown below The EXTERNAL OUTPUT1 and EXTERNAL OUTPUT2 port should be interfaced with the user device 20 i 4 3 EXTERNAL OUTPUT2 VOC 5V o T3 FROM PROCESSOR amp RELAY SPST Figure 1 8 a circuit of the output port The output port operates are as in the following Table 1 2 values of the output port value relay contact 0 RE ON geg The allowed output ports electrical current of voltage conditions are as in the following Table 1 3 voltage conditions of the output port Voltage Condition Allowed current The output ports are interfaced with a 5mm terminal block use a shaped screwdriver to connect it with users devices Sollae Systems Co Ltd 10 http www ezTCP com CIE H10 User s Manual Ver 3 1 1 5 3 RS232 Port DB9M The CIE H10 has an RS232 port supporting from 300
52. zManager sends query in every second dm Sollae Systems Co Ltd 50 http www ezTCP com wu CIE H10 User s Manual Ver 3 1 8 Additional Functions 8 1 Security 8 1 1 Restriction of Access ezTCP Firewall On the Option tab of ezManager users can set restriction of access function with filtering MAC and IP address Allowed MAC Address If this option has a value of MAC address the device which has the MAC address is only permitted to access Allowed IP Address This is for qualifying hosts with IP address or range of IP address The range is defined by multiplying IP address and Network Mask in bit unit Examples Table 8 1 examples of defining allowed IP range IP Address Network Mask Allowed IP Address Range 10 1 0 1 255 0 0 0 10 1 0 1 10 255 255 254 10 1 0 1 255 255 255 0 10 1 0 1 10 1 0 254 192 168 1 4 255 255 255 255 192 168 1 4 Apply to ezManager Apply to ezManager is for applying above two restrictions to ezManager functions like Search Read Write and etc 8 1 2 Setting Password A password can be used for protecting the CIE H10 from TELNET login or changing environmental parameters by hosts which are not qualified The maximum length is 8 bytes of Alphabet or number e When you want to revoke all of these restrictions change the mode of the CIE HIO to the ISP mode All restrictions are removable and communication with ezManager is revoked in the ISP mode MI co

Download Pdf Manuals

image

Related Search

Related Contents

Emerson 24000F Instruction Manual  Users Manual  Manuel de l`utilisateur Gesall    Polaroid PhotoMax MP3 Digital Camera  Software User`s Manual - Software Engineering I  Z10000 Installation & Maintenance Manual  ET 200S distributed I/O IM 151-8 PN/DP CPU interface  

Copyright © All rights reserved.
Failed to retrieve file