VECTOR et 2.140 Patient kurz-eng-280711-01

image

Contents

1. cleaning IMPORTANT If there is water remaining in the measuring tube pressure measuring may nega tively affect the therpay WEEKLY CLEANING OF THE DEVICE 1 Disconnect the power plug from the socket 2 Wipe the device with a cloth slightly moistened with soapy water Then use a dry cloth to wipe the device dry CLEANING THE HEAD GEAR Clean the head gear as required 1 Disconnect the head gear from the mask 2 Clean the head gear as described in the head gear manufacturer s user s manual HOFFRICHTER GmbH Mettenheimer Stra e 12 14 19061 Schwerin Germany pal Phone 49 385 39925 0 Fax 49 385 39925 25 E Mail info hoffrichter de Web www hoffrichter de VECTOR et 2 140 Patient kurz eng 2807 11 01 Art no 5000 0455 01 23
2. This document does not replace the manufacturer s user s manual Follow the user s manual Quality makes the Difference mm E m Display Programing keys Heater LED Filter cassette Heater key Unlocking button for humidifier Enter key h ie xe seb 9 gt ol 72 o on e a Q o S O O n o o N ou A jo Connection for measuring tube Connection for therapy tube Contact socket for humidifier on off key SUOHINASU PHT JO YUOLOIAN Insert SD card Rating plate RS232 interface Power connection 24V DC START END THERAPY To start or end the therapy press the on off key SETTING THE PARAMETERS The following 3 keys are available to set parameters at the device Programing key amp fs Enter key 2 s Exit Menu Programing key W 1 Press the enter key for approx 1 second 2 Switch to the next parameter with the programing key A in following sequence rilake Time G7 00 A Delete Filter A CHAS E VA A CE mea A pme A Exit Menu Exit Menu Exit Menu Exit Menu Exit Menu PAULO eee Start A Display UT 0NPY bBrishtness 100 A Date 25 May 11 A Time 13 00 i Exit Menu Exit Menu Exit Menu Exit Menu Exit Menu A flashing arrow k shows the active parameter 3 Press the enter key to change a parameter Adjust the desired value with the programing key A and V 5 Confirm the new valu
3. e by pressing the enter key only VECTOR et AUTO ALARM CLOCK ON OFF e Activate the alarm clock by using the programing key A The bell symbol appears at the display e Using the progaming key W the alarm clock will be deactivated The bell symbol disappears at the display SETTING THE WAKE UP TIME 1 Press the enter key for approx 1 second 2 Select Wake Time by using the programing keys A and V 8 Confirm by pressing the enter key 4 Set the wake up time by using the programing keys A and V 5 Confirm the wake up time by pressing the enter key INFO MENU Enter the Info Menu by pressing the info key i Here all adjusted parameters can be recalled Changes of these parameters can only be done by your physician or authorized dealer REPLACING THE FILTER CASSETTE If the filter is polluted or the display shows the message Change Filter the filter cassette must be replaced 1 To replace the filter cassette pull it out of the device 2 Replace filter cassette and filter frame cover 3 Replace the filter cassette by a new one 4 Insert the new filter cassette onto the filter frame cover Make sure the upper part slit and the filter cassette pin are in the correct position 5 Reset the filter counter Press the enter key Then select Delete Filter with the programing keys A and V Press the enter key twice 2 A CAUTION De Never op
4. erate the device without filter cassette Only o and exclusively use original HOFFRICHTER filter cas JUS settes de i Hi H 4 W H y HUMIDIFIER AquaDROP et optional Connect the humidifier Detach the humidifier from the device Setting heating level 1 Press the heater key until the heater menu is shown PHeatGNT Zz 2 Press the enter key The display of the heating level starts Exit Menu flashing PHEALING cece 2 3 Using the programing keys A and to set the desired hea WMZAtScu ting level Level 1 represents the lowest and level 5 the maxi mum heat output 4 Confirm the setting using the enter key Press the heating key j to switch on the humidifier s heating The display now shows the currently set heating level and the heater LED lights Press the heating key 1 again to switch off the humidifier s heating The heater LED goes off For more information please see AquaDROP et user s manual CLEANING DAILY CLEANING OF THE MASK 1 Separate mask and therapy tube 2 Use mild soap water dont use other additives for cleaning thoroughly rinse with clear water and let the mask dry at the air Protect it from direct sunlight exposure WEEKLY CLEANING OF THE THERAPY TUBE 1 Before cleaning close the measuring tube using the stoppers 2 Use mild soapy water for cleaning thoroughly rinse with clear water and let the tube dry at the air 3 Remove the two stoppers from the measuring tube after

Download Pdf Manuals

image

Related Search

Related Contents

GE HO97796 User's Manual  Philips Half-body solarium HB404    Manual de Usuario Quipux - Bandeja de Salida  Chambres d`hôtes - Office de Tourisme du Sud Charente  Samsung Duos Touch manual do usuário  Chromofy user manual - Gene  USER MANUAL - Oregon Scientific  ROI général de l`asbl COALA  HC2 HCK2 - Duplomatic Oleodinamica  

Copyright © All rights reserved.
Failed to retrieve file