Home
BALANZA ELECTRÓNICA CUENTAPIEZAS ELECTRONIC
Contents
1. 5g 55050430 30000 g 3000 10g 6000 5g 15000 2g 30000 1g The balance will be ready to start weighting Turn off 13 Recharging the batteries Try recharging the batteries once is completely discharged low battery indicator 3 will turn on By doing so you will increase the battery duration TA Ld BENE ene a Page 12 Instruction manual 55050XXX Version 1 June 03 5 FUNCTIONS OF THE BALANCE Tare Function Tare function is used when you want to wheight any substance without but not the reci pient containing it For instance when you want to weight liquids or solid reagents that you are going to dissolve afterwards You should do the following Make sure there is nothing on the pan 14 and check the display shows value 0 or 0 0 depending on gradation you choose Put the recipient on the balances pan 14 and then press TARE key 8 After this you will read 0 or 0 0 on the weight display depend gradation you choose The balance will be now ready to start weighing Once the weighting proccess is finished remove the recipient from the balance You will be able to read the recipient s weight with a negative value on the display To recover its usual mode press TARE key 8 again The display should show 0 or 0 0 again Piece counting Function Make sure there is nothing on the pan 14 check weight display 4 reads 0 0 0 depending on the gradation you choose If you need to put some recip
2. BALANZA ELECTR NICA CUENTAPIEZAS ELECTRONIC COUNTING BALANCE ahita Modelo 5050 5050 Model Este manual es parte inseparable del aparato por lo que debe estar disponible a todos los usuarios del equipo Le recomenda mos leer atentamente el presente manual y seguir rigurosamen te los procedimientos de uso para obtener las m ximas presta ciones y una mayor duraci n del mismo This manual should be available for all users of these equipments To get the best results and a higher duration of this equipment it is advisable to read carefully this manual and follow the processes of use Revisi n 1 de Junio 03 Manual de instrucciones 55050XXX P g 1 e Z x UN Ea Gracias por elegir una balanza NAHITA su alta calidad mec nica le permitir disponer de este instrumento por muchos a os no obstante le recomendamos leer atentamente el pre sente manual y seguir rigurosamente los procedimientos de uso para obtener las m ximas prestaciones y una mayor duraci n de la misma LEA DETALLADAMENTE ESTE MANUAL DE INSTRUCCIONES ANTES DE CONECTAR Y OPERAR CON ESTE EQUIPO Tenga especialmente presente lo siguiente Este manual es parte inseparable del aparato por lo que debe estar disponible a todos los usuarios del equipo Guarde el manual para posteriores consultas Cualquier duda puede ser aclarada contactando con el servicio t cnico de NAHITA Como instrumento de precisi n debe manipularse siempre con cuida
3. Pol gono Morea Norte 8 31191 BERIAIN Navarra ahita Tel 948 310 513 Fax 948 310 500 312 071 e mail asistencia auxilab com http www auxilab es pa Version 1 June 03 Instruction manual 55050XXX Page 15 ef m Z O Y z
4. T 4 Pantalla de peso 11 ACCU 5 Pantalla de peso unidad 12 SAMP 6 Teclado num rico 13 Interruptor ON OFF 7 ZERO 14 Plato Referencia Capacidad Sensibilidad 55050330 3000 g 0 1 g 55050360 6000 g 0 2 g 55050410 15000 0 5 55050430 30000 1 Medidas del plato 335 X 235 mm Tiempo estabilizaci n 10 segundos Temperatura de trabajo 5 a 40 C Alimentacion 220V 50 HZ Revision 1 de Junio 03 Manual de instrucciones 55050XXX Pag 3 Cia oO Z x UN m 4 INSTALACI N Inspecci n preliminar Desembale la balanza y aseg rese de que no presenta ning n da o debido al transporte De ser as comuniquelo inmediatamente a su transportista o suministrador Guarde el embalaje siempre se deben realizar las devoluciones en su embalaje original con todos los accesorios suministrados Instalaci n Antes de comenzar a utilizar el instrumento es conveniente familiarizarse con sus com ponentes y fundamentos b sicos as como con las funciones de sus controles LEA DETALLADAMENTE ESTE MANUAL DE INSTRUCCIONES ANTES DE CONECTAR Y OPERAR CON ESTE EQUIPO Col quelo sobre una mesa plana horizontal manteni ndolo alejado de la humedad calor polvo luz y vibraciones Mantenerlo sin ninguna fuerza magn tica campo el ctrico O aparato el ctrico que pueda generar campo de alta frecuencia Coloque el plato en su lugar tiene que insertar en los cuatro agujeros que tiene la carcasa Compruebe que el nivel est e
5. a balanza de movimientos bruscos y golpes as como de la luz directa del sol o corrientes de aire Trate la balanza con cuidado como un instrumento de precisi n que es Prot jala del polvo No desmonte la balanza adem s de perder la garant a podr a producir un da o impor tante en la balanza No tire el embalaje guardelo para transportarla o cuando no vaya a ser utilizada duran te cierto tiempo o haya que enviarla a revisar No eliminar los dispositivos de protecci n del sistema de mando no realizar presi n sobre la pantalla no presionar los mandos con objetos punzantes Utilice un pa o suave ligeramente humedecido con una soluci n detergente poco con centrada para limpiar la superficie accesible del instrumento No sumerja la balanza ni arroje l quido sobre ella Nunca use productos corrosivos Nota Seg n la legislaci n vigente en el campo de Instrumentos de pesaje de funciona miento no autom tico en el que se incluyen las balanzas mediante la Orden del 22 de diciembre de 1994 BOE 3 1 95 estas balanzas no se pueden utilizar para Realizaci n de transacciones comerciales C lculo de tasas Aranceles impuestos remuneraciones indemnizaciones y otros tipos de c nones similares Peritajes judiciales Preparaci n farmac utica de medicamentos por encargo as como realizaci n de an li sis efectuados en los laboratorios m dicos y farmac uticos Determinaci n del precio o impor
6. anty ATTENTION IF AN EQUIPMENT IS NOT PROPERLY CLEAN AND DISINFECTED IT WOULD NOT BE ALLOWED TO REPAIR BY OUR TECHNICAL SERVICE CONTENTS 1 USES OF THE INSTRUMENT tlc eas tiatin sap dlaas anced is 10 2 DESCRIPTION sida 10 3 TECHNICAL SPECIFICATIONS cocinan is 10 4 OPERATING INSTRUCTIONS cnica 11 5 FUNCTIONS OF THE BALANCE vecinos 13 6 MAINTENANCE cece hacen ulea tt aece acer eerie de anann 14 ANNEX I WARRANTY INFORMATION ninio 15 pa Version 1 June 03 Instruction manual 55050XXX Page 9 ef m Z O Y Z an 2 Z El 1 USES OF THE INSTRUMENT NAHITA electronic balances are basic instruments in weighing tasks in every laboratory They have been developed with the latest technology They are of a great reliability and durability Their solid clean and ergonomic design is very suitable for any industrial usage It s smooth surface makes the cleaning easier They are designed for every kind of uses in lots of fields thanks to the function to count pieces They are used in teaching laboratories pharmacy and industry chemistry etc 2 DESCRIPTION 1 Number Display 8 TARE Key 2 Level 9 CLEAR Key 3 Low battery indicator 10 SET Key 4 Weight Display 11 ACCU Key 5 Unit weight Display 12 SAMP Key 6 Number Key 13 Power ON OFF 7 ZERO Key 14 Pan Code Capacity Readability 55050330 3000 0 1 55050360 6000 g 0 2 g 55050410 15000 g 0 5 g 55050430 30000 g 1
7. do evitando los movimientos bruscos y los golpes Nunca desmonte las diferentes partes de la balanza para repararlas usted mismo adem s de perder la garant a podr a producir un funcionamiento deficiente de todo el conjunto ATENCION NO SE ADMITIRA NINGUN APARATO PARA REPARAR QUE NO ESTE DEBIDAMENTE LIMPIO Y DESINFECTADO INDICE DE CONTENIDOS 1 APLICACIONES siinne 3 2 DESCRIPCI N nn 3 3 ESPECIFICACIONES T CNICAS nn 3 A INSTALACI N uinumise nnii EA En 4 5 FUNCIONES DE LA BALANZA 6 MANTENIMIENTO Y LIMPIEZA ANEXO I GARANTIA Uf P g 2 Manual de instrucciones 55050XXX Revisi n 1 de Junio 03 1 APLICACIONES Las balanzas electr nicas Nahita son unos instrumentos b sicos en cualquier laboratorio para procesos de pesado est n desarrolladas con la ltima tecnolog a son de gran fiabilidad y durabilidad su s lido limpio y ergon mico dise o es muy apropiado para uso industrial La superficie lisa de la balanza permite su f cil limpieza Est n dise adas para todo tipo de aplicaciones en una gran variedad de campos ya que dispone de funci n cuenta piezas Su utilizaci n se extiende desde ense anza laboratorios farmacia hasta industria qu mica etc 2 DESCRIPCI N m 3 gt Z le i MAAM aJs 6 CAL pl ro Tare clear Ze 1 Pantalla de conteo 8 TARA 2 Nivel 9 CLEAR 3 Indicador de bater a baja 10 SE
8. e completely charged In order to do so insert the supplied cable in the schucko pin the plug it in to an intake earth conection The batteries is charged when the indicator of low battery is turned off Approximatel within two hours Neither the manufacturer nor the distributor will take any responsibility on damaged equipments or personal injuries due to an inappropriate connection to electricity Environmental work conditions Working temperature range 5 40 C Relative humidity 50 85 pa Version 1 June 03 Instruction manual 55050XXX Page 11 ef m Z O Y z Starting Switch on the power ON OFF 13 on the right hand side Check the level the balance incorporates in its back side 2 is in the appropriate position in the centre If it is in a wrong position try centering the bubble with the knobs close to the balance legs in the front and rear parts Balance begin self testing until getting normal weighting condition The displays will turn on and the balance will carry out a selftesting To choose the graduation sensibility you want to work withuse the SET key 10 Model capacity divided into graduation gives the weighting sensibility The higher gradation the better sensitivity the balance will work with Code Capacity Gradation Readability 55050330 3000 g 3000 1g 6000 0 5g 15000 0 2 g 30000 0 1 55050360 6000 g 3000 28 6000 lg 50000 30000 0 2 55050410 15000 g 3000 5g 6000 2 15000 1g 30000 0
9. e pesada Si trabajamos a la mayor graduaci n la balanza trabajara con la mejor sensibilidad m 3 gt Z ie i Referencia Capacidad Graduaci n Sensibilidad 55050330 3000 g 3000 1g 6000 0 5 g 15000 0 2 g 30000 0 1 55050360 6000 g 3000 2g 6000 Tg 50000 S O 30000 02g 55050410 15000 g 3000 5g 6000 2 15000 Tg 30000 0 5g 55050430 30000 g 3000 10g 6000 5g 15000 28 30000 Tg Ya tiene lista la balanza para su uso Apagar la balanza una vez acabado el trabajo Pulse el interruptor ON OFF situado en el lateral derecho 13 Recarga de la bater a Procure cargar la bater a s lo cuando este totalmente descargada el indicador bater a baja 3 se enciende De esta manera prolongar la vida de la bater a Revisi n 1 de Junio 03 Manual de instrucciones 55050XXX P g 5 Cia a ie Z S UN as 5 FUNCIONES DE LA BALANZA Funci n Tara La tara se emplea cuando se desea pesar sustancias pero no el recipiente que lo contiene por ejemplo cuando se quiere pesar l quidos o reactivos s lidos que luego se van a disolver Para su uso Asegurarse de que no haya nada en el plato 14 y comprobar que en la pantalla de peso 4 este a 0 0 0 dependiendo de graduaci n elegida Coloque el recipiente en el plato 14 de la balanza pulse TARA 8 y la pantalla de peso 3 mostrar 0 6 0 0 dependiendo de graduaci n elegida la balanza ya est preparada para pesar Una vez terminada la op
10. enimiento del aparato ni las piezas o los da os producidos por desgaste natural del uso normal del equi po Para facilitar un mejor servicio cuando nos env en un aparato al Servicio T cnico les agra decer amos nos indiquen los siguientes datos Distribuidos OOOO S Breve descripci n de la aver a AUXILAB S L 0 Pol gono Morea Norte 8 31191 BERIAIN Navarra ahita Tel 948 310 513 Fax 948 310 500 312 071 e mail asistencia auxilab com http www auxilab es 7 P g 8 Manual de instrucciones 55050XXX Revisi n 1 de Junio 03 Thanks for choosing a NAHITA Electronic Balance its high mechanical quality will allow you to make use of this equipment for a long years Nevertheless to get the best results and a higher duration out of this instrument it is highly advisable to read this manual and follow the instructions of use BEFORE CONNECTING OPERATING THIS INSTRUMENT READ THESE INSTRUCTIONS THOROUGHLY In order to use this equipment bear in mind the following points This manual is inseparable from the balance and must be available for all users of this equipment Any doubts can be clarified by getting in touch with the NAHITA service As an accuracy instrument it should be handled carefully avoiding the sudden move ments and knocks Never dismantle the different pieces of the balance to repair them yourself since it could produce a defective use of the whole equipment and a loss of the product warr
11. eraci n de pesada retire el recipiente del plato de la balanza en la pantalla quedar el peso del recipiente con valor negativo Para que se pueda seguir su manejo normal se debe poner a 0 6 0 0 con la tecla TARA 8 Funci n cuentapiezas Aseg rese de que no haya nada en el plato 14 compruebe que la pantalla de peso 4 este a 0 6 0 0 dependiendo de graduaci n elegida Si necesita colocar alg n tipo de recipiente utilice el modo TARA antes de trabajar con la balanza Coloque una unidad del producto a contar tenga en cuenta la sensibilidad que depen der seg n modelo Si el peso de la pieza es menor de lo indicado colocar 10 productos Cuando la balanza se encuentre estable marque con el teclado num rico 12 el peso de la unidad En la pantalla de peso unidad 5 aparece lo marcado Pulse ACCU 11 retire la pieza Ya esta preparada para el conteo coloque las piezas que quiera contar en pantallas apa recer Pantalla de conteo 1 le indica el numero de piezas Pantalla de peso unidad 5 le indica el peso de cada pieza Pantalla de peso 4 le indica el peso total de las piezas Una vez acabado el trabajo para borrar los datos pulse CLEAR 9 ACU 11 espere unos segundos y pulse de nuevo CLEAR 9 De esta manera borra los datos anteriores y puede comenzar de nuevo F ENE INV see 4 Uf P g 6 Manual de instrucciones 55050XXX Revisi n 1 de Junio 03 6 MANTENIMIENTO Evite a l
12. g Pan s size 335 X 235 mm Stabilization time 10 seconds Working temperature 5 to 40 C Power source 220V 50 HZ TA Wu Page 10 Instruction manual 55050XXX Version 1 June 03 4 OPERATING INSTRUCTIONS Preliminary examination Remove the instrument from the packing material and examine it carefully to make sure no damage has occurred during shipping If there is any damage notify to your dealer Keep all packing material until you are sure that the instrument works correctly All defective items must be returned in the original packing together with any other supplied accessories Installation Before using this instrument please carefully read this manual for its correct use BEFORE CONNECTING OPERATING THIS INSTRUMENT READ THESE INSTRUCTIONS THOROUGHLY The instrument must be placed on a flat horizontal desk Avoid wetness heat vibrations and airflows The environmental lighting must not be too bright Keep away from any mag netic force electric field or gadget with can produce a high frecuency fiel Place the pan on its place it must be inserted in the four holes that the balance has for this purpose Check the level the balance incorporates in its back side is in the appropriate position in the centre If it is in a wrong position try centering the bubble with the knobs close to the balance legs in the front and rear parts Charging the batteries Before using the balance its battery must b
13. ient you will use tare function Place a unit of product to be counted Bear in mind sensitivity that will depend on the balace model If the weight of the piece is smaller than indicated then place 10 units When the balance is stable introduce the unit weight by pressing the numbers keys 6 On the unit weight display you can read the weight as you press the key Press ACCU 11 Remove the piece The balance is now ready to start counting Place the product you want to count On dis plays you will read Number display 1 shows the number piece Unit Weight display 5 shows the weight piece Weight display 4 shows the total weight piece Once the work is finished for clearing data press CLEAR key 9 press ACCU key 11 and them wait for some seconds Press again CLEAR key 9 Now previous data is deleted and you can start again al Version 1 June 03 Instruction manual 55050XXX Page 13 ef m Z O Y zZ an 2 O Z m 6 MAINTENANCE Preserve the balance from heavy shocks and look for a dry place away from dust direct sun beams or air flows Handle the balance gently since it is an accurate instrument Use a smooth gauze with a soapy solution to clean it Never remove its mechanical components You will not only lose your warranty but also you can damage your balance seriously Don t throw away the package It might be useful in case you need to move it to send it if it needs re
14. n la posici n correcta centrado si no es asi centre la bur buja con los mandos situados en las patas delanteras y traseras de la balanza Carga de la bater a Antes de comenzar a usar la balanza deber cargar completamente la bater a Para ello inserte en la clavija shuko el cable que viene suministrado y enchufe a una toma de corriente que disponga de tierra La bater a se encontrar cargada cuando el indicador de bater a se encuentre apagado Aproximadamente dos horas Ni el fabricante ni el distribuidor asumir n responsabilidad alguna por los da os oca sionados al instrumento o por las lesiones producidas por cualquier persona debido a la inobservancia del correcto procedimiento de conexi n Condiciones ambientales de trabajo Temperatura de 5 40 C Humedad relativa 50 85 Uf P g 4 Manual de instrucciones 55050XXX Revisi n 1 de Junio 03 Puesta en marcha Presionar el interruptor ON OFF situado en el lateral derecho 13 Compruebe que el nivel 2 est en la posici n correcta centrado si no es asi centre la burbuja con los mandos situados en las patas delanteras y traseras de la balanza Se enciende las pantallas y la balanza realiza un autotest en las pantallas aparece 99999 hasta que se visualizar O 0 0 seg n graduaci n Elija con el bot n SET 10 la graduaci n sensibilidad con la que quiere trabajar La capa cidad del modelo dividido por la graduaci n nos da la sensibilidad d
15. oca tion The purchaser is responsible for insuring any returned product and assumes the risk of loss during shipping All replaced parts become the property of AUXILAB This limited warranty does not extend to any products which have been damaged as a result of accident misuse abuse or as a result of service or modification by anyone other than AUXILAB an authorised dealer or an authorised service location Except as expressly set forth above no other warranties are expressed or implied inclu ding but not limited to any implied warranties of merchantability or fitness for a particular purpose AUXILAB expressly disclaims all expressed or implied warranties not stated herein In order to obtain a free reparation or a free piece replacement by our Technical Service over the above mentioned period of time it is absolutely necessary to submit the Warranty Certificate This warranty doesn t apply for the maintenance of the equipment or for dama ged caused by a natural everyday use Some states do not allow the exclusion or limitation of incidental or consequential dama ges for consumer products and some states do not allow limitations on how long an implied warranty lasts so the above limitations or exclusions may not apply to you This limited warranty gives you specific legal rights and you may also have other rights which vary from state to state DC Sd Se al Number CC IS Brief failure description AUXILAB S L 0
16. pairing or you stop using it for a long time in the future Save all packing material until you are sure that the instrument works correctly All defec tive items must be returned in the original packing toghether with the supplied accessories Itis prohibited to use strong chemical solvent to clean the surface Do not leave the balance exposed to direct sunlight for long periods of time This may deform or discolor the cabinet and may also cause malfunctioning Please take out the dry batteries if it s to be left unused for a long time wipe the balance enclose it with dryer in a plastic pocket Do not press display Do not press front panel with sharp objects Don t dip the balance into water don t leave it out in the rain or even don t wash it with water In case some water drops please dry it inmediatly with a cloth f a d Page 14 Instruction manual 55050XXX Version 1 June 03 WARRANTY AUXILAB S L warrants this equipment be free from defects in material and workmans hip for a period of one year from date of purchase from AUXILAB S L or an authorised AUXILAB S L dealer This warranty is limited to such purchaser and is not transferable During the year warranty period AUXILAB S L will repair or replace at its option any defective equipments or pieces at no additional charge provided that the product is retur ned shipping prepaid to AUXILAB S L an authorised dealer or an authorised service l
17. te total en la venta directa al p blico y el la prepara ci n de preenvasados Ale Revision 1 de Junio 03 Manual de instrucciones 55050XXX Pag 7 Y m lt gt Z E e Z x 02 Ea GARANTIA AUXILAB S L garantiza este equipo por un periodo de doce meses a partir de la fecha de adquisici n contra cualquier defecto de fabricaci n que afecte a su funcionamiento com prometi ndose a reponer las piezas cuya rotura se deba a defecto de fabricaci n El canje durante el per odo de garant a de estas piezas ser gratuito y no implicar prolongaci n de la misma Esta garant a quedar sin efecto cuando el aparato haya sido sometido a un uso indebi do o manipulado por persona ajena a nuestro Servicio Oficial as como por haber sido ins talado incorrectamente o por haber utilizado recambios y accesorios no originales Quedan asimismo excluidas de la Garant a las aver as producidas por causas catastr fi cas fuego inundaci n atmosf ricas golpes y ca das Los gastos ocasionados como consecuencia de esta reparaci n tales como el transporte de los aparatos a nuestros Servicios Oficiales y su posterior devoluci n ser n por cuenta del usuario Es necesaria la presentaci n del Certificado de Garant a debidamente cumplimentado sin enmiendas ni tachaduras para obtener cualquier intervenci n de nuestro Servicio Oficial sin cargo durante el per odo indicado Esta garant a no cubre ni el mant