Home

Colony Counter Man SC6

image

Contents

1. Hold the lt save gt key down and switch the unit ON at the mains ON OFF switch Select either ON or OFF using the lt correct reset gt key To confirm press the lt average gt key The colony counter is now ready to use To turn the bleep on repeat steps 1 to 5 Cleaning the receiver plate The receiver plate can easily be removed for cleaning To remove make sure that the instrument is switched off at the mains Tip the colony counter upside down to remove the plate Clean the plate using a damp cloth only Once cleaned the plate should be returned to the colony counter Replacement plates are available see Spares and Accessories section Maintenance amp Servicing WARNING Ensure the unit is disconnected from the mains electricity supply before attempting maintenance or servicing Periodically clean the instrument using a damp cloth and mild detergent solution Do not use harsh or abrasive cleaning agents Any repairs or replacement of parts MUST be undertaken by suitably qualified personnel Spares and Accessories The following spares and accessories are available from your laboratory dealer Description Catalogue Number x1 7 magnifier SC6 1 x3 magnifier SC6 1 3 Wolffhuegel graticule amp segmentation disk pack of 10 SC6 2 Centering adapter pack of 2 SC6 3 Clear protective discs pack of 10 SC6 4 Receiver plate SC6 5 For a comprehensive list of parts required by service engineers
2. Colony Counter SC6 y SC6 100V 50 SC6 100V 60 SC6 120V 60 SC6 220V 50 SC6 220V 60 Instructions for use Manuel d utilisation Istruzioni per l uso Instrucciones de funcionamiento Bedienungsanweisung Bibby Scientific English Control panel Magnifier position Receiver Sensitivity adjustment plate Mains ON OFF switch Figure 1 SC6 controls Background djust t re Thank you for purchasing this piece of Bibby Scientific equipment To get the best performance from the equipment and for your own safety please read these instructions carefully before use This equipment is designed to operate under the following conditions lt For indoor use only Use in a well ventilated area lt Ambient temperature range 5 C to 40 C Altitude to 2000m Relative humidity not exceeding 80 Mains supply fluctuation not exceeding 10 Overvoltage category Il IEC60364 4 443 Pollution degree 2 IEC664 Dish adapters If the equipment is not used in the manner described in this manual the protection provided Figure 2 Underneath the SC6 by the equipment may be impaired AN Electrical Installation D THIS EQUIPMENT MUST BE EARTHED Before connection please read and understand this instruction manual and ensure that the line supply corresponds to that shown on the rating plate Power consumption is Model Power Frequency Fuses SC6 70W 50Hz 2xF3 15A SC6 100V 50 70W 50Hz 2xF3
3. Ersatzteile und Zubeh r 22 Wartung amp Reparatur WARNUNG Stellen Sie sicher dass das Ger t vom Netzanschlu getrennt wurde bevor Sie Wartungs oder Reparaturarbeiten durchf hren Reinigen Sie das Ger t regelm ig mit einem feuchten Tuch und einer milden Waschl sung Verwenden Sie keine starken oder abrasiven Reinigungsmittel Sowohl die Reparaturen als auch der Einbau von Ersatzteilen MUSS von ausreichend qualifiziertem Personal ausgef hrt werden Ersatzteile und Zubeh r Die folgenden Ersatz und Zubeh rteile sind bei Ihrem H ndler f r Laborartikel erh ltlich Beschreibung Bestellnummer x1 7 Vergr erungslupe SC6 1 x3 Vergr erungslupe SC6 1 3 Wolffh gelraster Segmentscheiben 10er Pack SC6 2 Reduzierringe 2er Pack SC6 3 Klarschutzscheiben 10er Pack SC6 4 Receiver Platte SC6 5 Eine ausf hrliche Liste der Ersatzteile auch f r technisches Personal erhalten Sie ber die Verkaufsabteilung von Bibby Scientific Ltd Bitte Modell und Seriennummer angeben Es sollten ausschlie lich die von Bibby Scientific Ltd oder seinen Agenten empfohlenen Ersatzteile verwendet werden Das Anbringen von nicht genehmigten Teilen kann die Leistung und die Sicherheitsfunktionen des Instrumentes negativ beeintr chtigen Falls Zweifel bestehen sollten wenden Sie sich an die Technische Serviceabteilung von Bibby Scientific Ltd oder an Ihren Handler Bibby Scientific Ltd Stone Staffordshi
4. 2 illustra la parte sottostante dell apparecchio Funzionamento Messa a punto del contacolonie SC6 Per scegliere tra sfondo bianco o nero spostare il pannello sotto l apparecchio verso destra o verso sinistra fino a quando si avverte un clic Per utilizzare una capsula Petri dal diametro inferiore ai 90 mm scegliere il riduttore idoneo reperibile nella parte sottostante dell apparecchio e sistemarlo sul piano di appoggio Il contacolonie SC6 viene fornito con una confezione di dischetti trasparenti destinati a proteggere il piano di appoggio da eventuali graffiature Sistemare un disco protettivo sul piano di appoggio Qualora il disco venga successivamente danneggiato toglierlo e sostituirlo con un disco nuovo Qualora sia necessario utilizzare una graticola Wolffhuegel o un disco di separazione poggiarli sopra il disco protettivo trasparente sistemato sul piano di appoggio Posizionare l apparecchio su una superficie in piano La manopola di regolazione della sensibilit posta sul retro dell apparecchio serve per regolare la pressione da esercitare per registrare il conteggio Ruotare la manopola in senso orario per aumentare la sensibilit in senso antiorario per diminuirla In caso di conteggio di colonie particolarmente piccole disponibile una lente d ingrandimento che si monta avvitando l astina di supporto snodabile nell area prevista nella parte superiore dell apparecchio Orientare l astina fino a
5. Ponga un disco en la placa receptora Si est da ada extr igala y sustit yala por otra placa Si es necesario instalar la ret cula Wolffhuegel o el disco de segmentaci n p ngalos encima del disco de protecci n transparente sobre la placa receptora 15 Ponga el dispositivo sobre una superficie nivelada firme El pomo de control de sensibilidad situado en la parte posterior de la unidad permite ajustar la presi n necesaria para registrar un recuento Si se gira en el sentido de las agujas del reloj se aumentar la sensibilidad y si se gira en sentido contrario se disminuir Si se van a contar colonias peque as existe disponible un accesorio de lupa Para montarla enrosque el brazo de soporte flexible en el rea espec fica situada en la parte superior de la unidad Ajuste el brazo de soporte flexible hasta obtener el aumento y el campo de visi n necesario Encienda la unidad con el interruptor ON OFF situado en la parte posterior de la unidad Recuento Coloque la placa de cultivo sobre la placa receptora con el adaptador de centrado si es necesario Aseg rese de que la pantalla est ajustada en cero antes de continuar manteniendo pulsada la tecla lt correct reset gt corregir reajustar Marque cada colonia con un rotulador Cada vez que se marca una colonia el aparato registrar el n mero con un pitido y avance del contador Si se realiza un recuento no deseado se puede borrar de la pantalla pulsando
6. de la l nea corresponde al mostrado en la placa de r gimen de trabajo Este modelo requiere un suministro con r gimen a 220 240V 50 Hz monof sico Requerimientos energ ticos Modelo Vatiaje SC6 22W Hay una toma IEC en la parte posterior del instrumento para la conexi n al suministro de la red El instrumento se envia con dos cables de la red provistos de enchufes IEC para efectuar la conexi n Uno de los cables incorpora un enchufe de 3 clavijas tipo Reino Unido mientras que el otro incorpora un enchufe de 2 clavijas tipo Shuko para efectuar la conexi n a la red Seleccione el cable apropiado para su instalaci n el ctrica y deseche el otro Si ninguno de los cables fuese adecuado tome el cable con el enchufe tipo Reino Unido y sustituya ste por uno alternativo adecuado Vea la hoja de datos adjunta c mo efectuar esta operaci n Si es preciso recambiar el cable de la red deber ps 2 utilizarse un cable de 1mm homologado de c digo HO5W F conectado a un enchufe IEC 320 EN CASO DE DUDAS CONSULTE A UN ELECTRICISTA PROFESIONAL EI cable de red la deber conectarse al instrumento ANTES de ser conectado al suministro de la red Descripci n General La unidad consta de una placa receptora iluminada y una pantalla LED grande La presi n del marcado de una colonia con un rotulador registra un n mero mediante un pitido y lo presenta en una pantalla digital Una funci n incorporada de promediado permi
7. di codice HO5W F armonizzato connesso ad una spina CEI 320 IN CASO DI DUBBIO CONSULTARE UN ELETTRICISTA QUALIFICATO Si deve connettere il cavo da rete allo strumento PRIMA di eseguire la connessione all alimentazione da rete Generalit L apparecchio composto da un piano di appoggio illuminato e da un display LED di grandi dimensioni La pressione esercitata dal pennarello utilizzato per marcare una colonia registra il 10 conteggio con un segnale acustico e incrementa il numero sul display digitale La funzione di calcolo della media incorporata consente di conteggiare pi di una capsula e di calcolare la media della colonia La pressione esercitata per registrare il conteggio regolabile Lo sfondo disponibile in bianco e in nero e l apparecchio prevede la dotazione di serie di una graticola Wolffhuegel di un disco di segmentazione e di riduttori di centraggio per capsule da 50 a 90 mm anche disponibile su richiesta una lente d ingrandimento per il conteggio di colonie particolarmente piccole Norme di sicurezza da osservare prima dell uso Trasportare l apparecchio con entrambe le mani Non trasportare mai l apparecchio quando in funzione o collegato all alimentazione elettrica In caso di interruzione dell erogazione di corrente di avaria o guasto elettrico l apparecchio riprender a funzionare una volta eliminato il problema Comandi La Figura 1 illustra i comandi del SC6 La Figura
8. la enfonc e jusqu ce que l afficheur revienne z ro Ceci va effacer de la m moire les num rations sauvegard es Une fois toutes les num rations termin es mettez l appareil hors tension Allumer ou teindre le bip sonore de comptage Eteignez l appareil sur l interrupteur secteur Marche Arr t Maintenez la touche lt save gt enfonc e et mettez l appareil sous tension gr ce l interrupteur secteur Marche Arr t S lectionnez soit ON marche soit OFF arr t l aide de la touche lt correct reset gt Pour confirmer appuyez sur la touche lt average gt Le compteur de colonies est maintenant pr t l emploi Pour activer le bip r p tez les tapes 1 5 Nettoyage de la platine r ceptrice La platine r ceptrice se d monte facilement pour le nettoyage Pour la d monter v rifiez que l appareil est teint et hors tension Retournez le compteur de colonie sens dessus dessous pour d poser la platine Nettoyez la platine l aide d un chiffon humide uniquement Une fois nettoy e la platine devra tre replac e sur le compteur de colonies Des platines de rechange sont disponibles consulter le chapitre Pi ces de rechange et accessoires Entretien et maintenance ATTENTION V rifier que l appareil est d connect de son alimentation lectrique avant toute op ration de maintenance ou d entretien Les surfaces de l appareil et les accessoires peuvent tre nettoy
9. non superiori a 10 Categoria di sovratensione Il CEI60364 4 443 Grado di contaminazione 2 CEl664 Riduttori per capsule Se l apparecchio non usato come specificato nel Figure 2 presente manuale la protezione offerta Parte sottostante del contacolonie SC6 dall apparecchio stesso pu essere ridotta AN Installazione Elettrica QUESTO APPARECCHIO DEVE ESSERE MESSO A TERRA Prima di connetterlo assicurarsi che l alimentazione di linea corrisponda a quella indicata sulla targhetta con i dati caratteristici dell apparecchio Questo modello richiede un alimentazione nominale monofase di 220 240V 50 Hz in c a Requisiti di energia Modelli Potenza nominale SC6 22W Al retro dello strumento esiste una presa CEI di connessione all alimentazione da rete L unit viene fornita con due cavi d alimentazione dotati di spine CEI per connessione allo strumento Un cavo ha una spina con terra standard del Regno Unito e l altro ha una spina Shuko a due piedini soli per connessione a rete Scegliere il cavo adatto all installazione elettrica del posto e gettar via l altro In caso nessuno dei due cavi sia adatto prendere il cavo con la spina standard del Regno Unito e sostituire la spina con un tipo adatto al caso Vedere la scheda di istruzioni inclusa che contiene consigli sulle modalit per effettuare tale sostituzione Se occorre sostituire il cavo da rete occorre impiegare un cavo di sezione 1mm
10. operazione fino a quando si avr eseguito il conteggio per tutte le capsule Al termine dell operazione premere il tasto lt average gt per visualizzare la media che viene calcolata dai conteggi memorizzati in precedenza Volendo possibile visualizzare la media durante il conteggio delle singole capsule Petri premendo il tasto lt average gt quando appaiono le tre lineette sul display L attivazione della funzione calcolo della media viene segnalata dall accensione della spia LED rossa nell angolo superiore sinistro del display 11 AVERAGE Lit pe Figura 5 Funzione calcolo della media attiva sul contacolonie SC6 Per ripristinare il conteggio premere di nuovo il tasto lt average gt A conteggio ultimato premere e tenere premuto il tasto lt correct reset gt fino a quando appare la cifra zero sul display Cosi facendo si cancellano dalla memoria tutti conteggi memorizzati in precedenza A conteggio ultimato spegnere l apparecchio agendo sull interruttore di accensione ON OFF Attivazione e disattivazione del segnale acustico di conteggio Spegnere l apparecchio agendo sull interruttore di accensione ON OFF Tenere premuto il tasto lt save gt ed accendere l apparecchio agendo sull interruttore di accensione ON OFF Scegliere ON attivazione o OFF disattivazione agendo sul tasto lt correct reset gt Premere il tasto lt average gt per confermare Il contacolonie pronto per l uso
11. s l aide d un linge doux et humide et un d tergent appropri La lentille peut tre d mont e de son support pour le nettoyage Pour retirer la fen tre de protection du bloc chauffant glisser le clip de retenue avec de fine pinces et nettoyer avec un chiffon tr s doux Pi ces d tach es et accessoires Pour obtenir une liste exhaustive des pi ces n cessaires aux techniciens de maintenance qui effectuent des r parations internes veuillez contacter le Service des Ventes de Bibby Scientific Ltd en mentionnant le mod le et le num ro de s rie 8 Description R f rence catalogue Loupe x1 7 SC6 1 Loupe x3 SC6 1 3 R ticule de Wolffhuegel et disque de segmentation paquet de 10 SC6 2 Adaptateur de centrage paquet de 2 SC6 3 Disques de protection translucides paquet de 10 SC6 4 Platine r ceptrice SC6 5 Seules les pi ces de rechange fournies ou indiqu es par Bibby Scientific France ou ses revendeurs doivent tre employ es L utilisation de pi ces non approuv s peut affecter le fonctionnement et la s curit de l instrument En cas de doute contacter avec le service technique de Bibby Scientific France ou votre revendeur T l 33 1 64 45 13 13 Fax 33 1 64 45 13 00 Garantie Bibby Scientific Ltd garantit cet instrument comme exempt de d fauts de mat riaux et de fabrication s il est utilis dans les conditions habituelles du laboratoire pendant une p riode de trois 3 ans
12. teunterseite Bedienung Einrichten des SC6 Kolonienz hlger ts Die auf der Unterseite befindliche Scheibe bis zum Einrasten nach rechts oder nach links schieben um einen hellen oder dunklen Hintergrund zu w hlen F r Petrischalen mit einem Durchmesser unter 90 mm muss der entsprechende Adapter auf den Z hlteller aufgesetzt werden Dieser Teller befindet sich ebenfalls auf der Ger teunterseite Das SC6 wird mit einer Packung klarer Scheiben geliefert die dazu dienen den Z hlteller vor Staub und Kratzern zu sch tzen Eine solche Scheibe in den Z hlteller einsetzen Sollte diese Scheibe besch digt werden ist sie gegen eine neue Scheibe auszutauschen Ein evtl verwendetes Wolffh gelraster bzw die Segmentscheibe muss oben auf die Klarscheibe die sich auf dem Z hlteller befindet aufgelegt werden Das Ger t auf einer festen ebenen Oberfl che aufstellen Mit dem Empfindlichkeitsregler auf der Ger ter ckseite kann die Druckempfindlichkeit zur Z hlimpulsausl sung eingestellt werden Bei Drehung im Uhrzeigersinn erh ht sich die Empfindlichkeit in umgekehrter Richtung verringert sie sich F r die Z hlung kleiner Kolonien ist eine Lupe als Zubeh r erh ltlich Dazu den biegsamen Arm in die Halterung oben am Ger t einschrauben Dann den biegsamen Arm so einstellen dass die gew nschte Vergr erung bzw das erforderliche Gesichtsfeld erreicht wird Das Ger t mit dem EIN AUS Schalter auf der Ger ter cksei
13. una vez la tecla lt correct reset gt para cada recuento Cuando se haya completado el recuento ajuste la pantalla en cero con la tecla lt correct reset gt o apague la unidad del suministro el ctrico CORRECT SAVE AVERAGE Figura 3 SC6 Panel de control 16 Promediado Para utilizar la funci n de promediado coloque la placa de cultivo sobre la placa receptora Al final del recuento pulse la tecla lt save gt guardar para guardar el recuento en la memoria lo cual vendr indicado por tres rayas en la pantalla CORRECT SAVE AVERAGE Figura 4 Guardar recuentos en la SC6 Coloque la placa de cultivo sobre la siguiente y pulse lt save gt para reanudar el recuento Repita hasta que se hayan contado todas las placas Al final de la operaci n pulse la tecla lt average gt promedio para mostrar el recuento promedio Se calcular el recuento promedio de todos los recuentos guardados anteriormente y se podr ver en cualquier momento durante el recuento de lotes de las placas de cultivo pulsando la tecla lt average gt cuando se muestren las tres rayas en la pantalla Cuando la funci n de promediado est activa se mostrar un punto LED en la esquina superior izquierda de la pantalla CORRECT SAVE AVERAGE Figura 5 Funci n de promediado activa en la SC6 Para reanudar el recuento pulse de nuevo la tecla lt average gt Cuando el recuento se haya completado mantenga pulsada la tecl
14. 15A SC6 100V 60 70W 60Hz 2xF3 15A SC6 120V 60 70W 60Hz 2xF3 15A SC6 220V 50 70W 50Hz 2xF3 15A SC6 220V 60 70W 60Hz 2xF3 15A The SC6 model is supplied with two mains leads fitted with IEC plugs for connection to the instrument One has a UK 3 pin plug and the other has 2 pin Shuko plug for connection to the mains Choose the lead appropriate for your electrical installation and discard the other Should neither lead be suitable take the lead with the UK plug and replace the plug with a suitable alternative This involves cutting off the moulded plug preparing the cable and connecting to the rewireable plug in accordance with its instructions IT IS IMPORTANT THAT THIS OPERATION SHOULD ONLY BE UNDERTAKEN BY A QUALIFIED ELECTRICIAN NOTE Refer to the equipment s rating plate to ensure that the plug and fusing are suitable for the voltage and wattage stated The wires in the mains cable are coloured as follows Live Brown Neutral Blue Earth Green yellow The instruments are fitted with an IEC socket at the rear of the instrument for connection of the mains lead The appropriate mains lead should be connected BEFORE connection to the mains supply Should the mains lead need replacement a cable of 1mm of harmonised code HO5W F connected to an IEC320 plug should be used N B the UK mains lead is protected by a 10A fuse mounted in the plug top IF IN DOUBT CONSULT A QUALIFIED ELECTRICIAN General Description Th
15. 80 Schwankungen der Netzstromversorgung nicht Uber 10 Uberspannungskategorie Il IEC 60364 4 443 lt Verschmutzungsgrad 2 IEC 664 Schalenadapter Der Einsatz des Gerates auf eine im Handbuch Abbildung 2 Ger teunterseite SC6 nicht vorgesehene Weise kann eine Beeintrachtigung des durch dieses Ger t gegebenen Schutzes zur Folge haben 19 Elektrische Installation DIESES GERAT MUSS GEERDET WERDEN Vergewissern Sie sich vor dem AnschluB des Ger tes dass es sich um eine Netzstromversorgung gem B Typenschild handelt Dieses Modell ben tigt eine einphasige Netztstromversorgung mit 220 240V 50 Hz Strombedarf Modell Wattleistung SC6 22W An der R ckseite des Ger tes befindet sich eine IEC Buchse zur Verbindung mit der Netzstromversorgung Das Ger t verf gt ber zwei Netzkabel mit IEC Steckern zur Verbindung mit dem Instrument Ein Kabel besitzt einen 3 stiftigen Stecker GB w hrend der andere ber einen 2 stiftigen Schuko Stecker zur Verbindung mit dem Netz verf gt Verwenden Sie das f r Ihre elektrische Anlage geeignete Kabel und entsorgen Sie das andere Kabel Sollten beide Kabel ungeeignet sein verwenden Sie das Kabel mit dem GB Stecker und ersetzen Sie den Stecker durch eine geeignete Alternative Dieses Verfahren wird auf dem beigef gten Informationsblatt beschrieben Falls ein Austausch des NetzanschluBkabels erforderlich ist sollte ein Kabel mit 1mm des Harmonisierungsco
16. En cas de r clamation justifi e Bibby Scientific remplacera tout composant d fectueux ou proc dera l change de l appareil gratuitement Cette garantie NE S APPLIQUE PAS en cas de d g ts provoqu s par un incendie un accident une erreur d utilisation une n gligence un r glage ou une r paration incorrects en cas de d g ts provoqu s par l installation l adaptation la modification le montage de pi ces non approuv es ou la r paration par un personnel non autoris Caract ristiques techniques DEL 3 chiffres 0 999 Jusqu 90 mm 310 x 300 x 140 mm 1 5 kg Afficheur num rique Compteur Taille des bo tes Dimensions I x L x h Poids net Italiano Quadro di comando Posizione lente d ingrandimento Piano di Regolazione sensibilita appoggio Interruttore di accensione Figure 1 Comandi del contacolonie SC6 Regolazione Vi ringraziamo per aver acquistato questo sfondo apparecchio Bibby Scientific Per ottenerne le migliori prestazioni e per la vostra sicurezza vogliate leggere con cura queste istruzioni prima di adoperarlo L apparecchio stato progettato per un funzionamento nelle seguenti condizioni Da usarsi solo all interno Da usarsi in un area ben ventilata lt In un campo di variazione di temperatura da 5 C a 40 C Ad un altitudine massima di 2000 metri Con una umidit relativa non superiore a 80 Con fluttuazioni dell alimentazione da rete
17. Per disattivare il segnale acustico di conteggio se lo si era attivato nell operazione suindicata eseguire le operazioni descritte nei punti da 1 a 5 Pulizia della piastra di supporto La piastra di supporto pu essere facilmente rimossa per la pulizia Per la rimozione assicurarsi che lo strumento sia spento e scollegato dall alimentazione di rete Rovesciare il contacolonie per rimuovere la piastra Pulire la piastra usando esclusivamente un panno umido Dopo la pulizia collocare 12 nuovamente la piastra nel contacolonie Sono disponibili piastre sostitutive v sezione Ricambi e accessori Manutenzione e riparazioni ATTENZIONE Assicurarsi che l unit sia scollegata dall alimentazione elettrica prima di effettuare manutenzione o riparazioni Pulire lo strumento ad intervalli regolari con un panno umido ed una soluzione di detersivo leggero Non impiegare detersivi troppo forti o abrasivi Riparazioni o sostituzioni di parti DEVONO essere eseguite da personale opportunamente qualificato Ricambi e accessori Dal vostro concessionario di apparecchiature per laboratorio sono disponibili le seguenti parti di ricambio ed i seguenti accessori Denominazione Codice catalogo Lente di ingrandimento x 1 7 SC6 1 Lente di ingrandimento x3 SC6 1 3 Graticola Wolffhuegel amp dischetto di separazione confezione da 10 pezzi SC6 2 Riduttore di centraggio confezione da 2 pezzi SC6 3 Dischetti protettivi t
18. a lt correct reset gt hasta que la pantalla regrese a cero lo que borrar los recuentos guardados la memoria Cuando se haya completado todo el recuento desconecte el suministro el ctrico de la unidad Encender o apagar el pitido de recuento Apague la unidad en el interruptor ON OFF de suministro el ctrico Mantenga pulsada la tecla lt save gt y encienda la unidad con el interruptor ON OFF de suministro el ctrico Seleccione ON u OFF con la tecla lt correct reset gt Para confirmar pulse la tecla lt average gt El contador de colonia estar listo para utilizarse Para encender el pitido repita los pasos 1 a 5 Limpieza de la placa receptora La placa receptora puede ser desmontada f cilmente para su limpieza Antes de desmontar la placa asegure que el instrumento haya sido desenchufado de la red Vuelva el contador de colonias boca abajo para desmontar la placa Limpie la placa con un trapo h medo solamente Despu s de la limpieza la placa deber retornarse al contador de colonias Hay disponibles placas de repuesto vea la secci n de Repuestos y accesorios Mantenimiento y servicio AVISO Asegure que el instrumento est desconectado del suministro de la red entes de efectuar cualquier trabajo de mantenimiento o servicio Limpie peri dicamente el instrumento con un trapo h medo y una soluci n detergente suave No use productos de limpieza speros o abrasivos Todo el trabajo de repa
19. abricaci n cuando se utiliza en condiciones normales de laboratorio durante un per odo de tres 3 a os En caso de una reclamaci n justificada Bibby Scientific sustituira los componentes defectuosos o toda la unidad sin cargo alguno Esta garantia NO cubre los da os ocasionados por incendio accidente uso incorrecto negligencia ajuste o reparaci n incorrectos da os producidos por la instalaci n adaptaci n modificaci n montaje de piezas no autorizadas o reparaci n efectuada por personal no autorizado Especificaciones t cnicas Pantalla digital LED de 3 digitos Recuento 0 a 999 Tama o de placa Hasta 90 mm Dimensiones anchura x profundidad x altura 310 x 300 x 140 mm Peso neto 1 5 Kg 18 Deutsch Bedienfeld Aufnahme f r L urna ur Lupe Zahiteller Empfindlichkeitseinstellung Netz EIN AUS Schalter Abbildung 1 SC6 Bedienelemente Vielen Dank dass Sie sich f r dieses Ger t von Bibby Scientific entschieden haben Damit bei der Nutzung des Ger tes Ihre eigene Sicherheit gew hrleistet ist und die optimale Leistung erzielt werden kann sollten Sie diese Anweisungen vor der Verwendung aufmerksam lesen Einstellung des Hintergrunds Dieses Ger t ist f r die folgenden Betriebsbedingungen ausgelegt Nur zur Verwendung im Innenbereich Nutzung in einem gut bel fteten Bereich Umgebungstemperaturbereich 5 C bis 40 C H he bis 2000m Relative Luftfeuchtigkeit nicht ber
20. cientific France SAS fe ZI du Rocher Vert BP 79 Bibby Scientific 17732 Nemours Cedex rance Tel 33 1 64 45 13 13 Fax 33 1 64 45 13 00 e mail bsf bibby scientific fr www bibby scientific com Bibby Scientific Ltd Bibby Scientific US Ltd Beacon Road Stone 3 Terri Lane Suite 10 Staffordshire ST15 OSA Burlington NJ 08016 United Kingdom USA Tel 44 0 844 936 0234 Tel 800 225 9243 Fax 44 0 844 936 0235 Fax 609 589 2571 email info bibby scientific com www bibby scientific com www bibby scientific com Bibby Scientific talia Srl Via Alcide de Gasperi 56 20077 Riozzo di Cerro al Lambro Milano ltalia Tel 39 0 2 98230679 Fax 39 0 2 98230211 e mail marketing bibby scientific it www bibby scientific it Afora S A Calle Aribau 240 08006 Barcelona Spain Tel 343 93 306 98 00 Fax 343 93 306 98 23 e mail marketing afora com www afora com
21. conducting internal repairs please contact the Sales Department at Bibby Scientific Ltd quoting both the model and serial number Only spare parts supplied or specified by Bibby Scientific Ltd or its agents should be used Fitting of non approved parts may affect the performance and safety features designed into the instrument If in any doubt please contact the Technical Service Department of Bibby Scientific Ltd or the point of sale Bibby Scientific Ltd Stone Staffordshire ST15 OSA United Kingdom Tel 44 0 844 936 0234 Fax 44 0 844 936 0235 e mail info bibby scientific com www bibby scientific com Warranty Bibby Scientific Ltd warrants this instrument to be free from defects in material and workmanship when used under normal laboratory conditions for a period of three 3 years In the event of a justified claim Bibby Scientific will replace any defective component or replace the unit free of charge This warranty does NOT apply if damage is caused by fire accident misuse neglect incorrect adjustment or repair damage caused by installation adaptation modification fitting of non approved parts or repair by unauthorized personnel Technical Specification Digital display 3 digit LED Count 0 to 999 Dish size Up to 90 mm Dimensions w x d x h 310 x 300 x 140 mm Net weight 1 5Kg Fran ais Panneau de commande Position de la loupe Plaque R glage de sensibilit receptrice Interru
22. des HO5W F verwendet werden das an einen IEC 320 Stecker angeschlossen wurde FALLS ZWEIFEL BESTEHEN WENDEN SIE SICH AN EINEN QUALIFIZIERTEN ELEKTRIKER Das Netzkabel sollte VOR dem AnschluB an die Netzstromversorgung mit dem Instrument verbunden werden 20 Allgemeine Beschreibung Das Ger t besteht aus einem beleuchteten Z hlteller und einem gro en LED Display Der Druck beim Markieren einer Kolonie mit dem Filzstift l st einen Z hlimpuls mit akustischem Signal aus und wird auf dem Digital Display angezeigt Mit Hilfe der eingebauten Durchschnittsberechnung k nnen mehrere Teller gez hlt werden um dann den Durchschnitt der Kolonienz hlung zu bilden Der erforderliche Druck f r die Ausl sung einer Z hlung ist einstellbar Es stehen helle und schwarze Kontrastscheiben zur Verf gung Das Ger t wird mit einem Wolffh gelraster einer Segmentscheibe und Reduzierringen f r Schalen von 50 90 mm Durchmesser geliefert F r die Z hlung sehr kleiner Kolonien ist eine Lupe als Zubeh r erh ltlich Sicherheitshinweis Das Ger t muss mit beiden H nden getragen werden lt Das Ger t niemals transportieren wenn es in Betrieb oder an die Stromversorgung angeschlossen ist lt Im Fall eines Stromausfalls einer St rung oder eines elektrischen Fehlers schaltet sich das Ger t nach Beheben der St rung wieder ein Bedienelemente Abbildung 1 zeigt die Bedienelemente f r das SC6 Abbildung 2 zeigt die Ger
23. e SC6 is provided with a pack of clear discs designed to protect the receiver plate from dust and scratches Place a disc in the receiver plate If this becomes damaged remove and replace with another If the Wolffhuegel graticule or segmentation disc is required place on top of the clear protective disc on the receiver plate Position the apparatus on a firm level surface The sensitivity control knob located at the back of the unit can adjust the pressure required to register a count Turning it clockwise will increase the sensitivity turning it anti clockwise will decrease the sensitivity If small colonies are to be counted a magnifier is available as an accessory To assemble screw the flexible support arm in to the designated area located on top of the unit Adjust the flexible support arm until the required magnification and field of view is achieved Turn the unit ON at the ON OFF switch located at the back of the unit Counting Position the Petri dish on the receiver plate using the centering adapter if required Ensure the display is set to zero before counting by pressing and holding the lt correct reset gt key Mark each colony with a felt tip pen Every time a colony is marked the apparatus will register the count with a bleep and counter advance If unwanted counts are made they can be removed from the display by pressing the lt correct reset gt key once for each count When the count is complete
24. e unit consists of an illuminated receiver plate and a large LED display The pressure of marking a colony with a felt tip pen registers a count by an audible bleep and advance on a digital display A built in averaging facility allows multiple plates to be counted and then the average colony count calculated The pressure required to register a count can be adjusted A choice of light or black background is available and the unit is supplied complete with one Wolffhuegel graticule segmentation disc and centering adapters for 50 90mm dishes A magnifier for counting very small colonies is available as an accessory Safety Advice Before Use lt The unit should be carried using both hands Never move or carry the unit when in use or connected to the mains electricity supply In the case of mains interruption a fault or electrical failure the unit will continue to operate on removal of the fault Controls Figure 1 shows the controls for the SC6 Figure 2 shows the underside of the unit Operation Setting up the SC6 Colony Counter NOTE All voltage variants operate in the same Way To select either the dark or white background slide the panel which can be found underneath the unit to the left or right until the background clicks home in to place To use a petri dish of less than 90mm in diameter select the appropriate adapter which can also be found on the underside of the unit and place on the receiver plate Th
25. either set the display to zero using the lt correct reset gt key or switch the unit OFF at the mains CORRECT AVERAGE Figure 3 SC6 Control Panel Averaging To use the averaging facility place the first Petri dish on the receiver plate At the end of the count press the lt save gt key to store the count in the memory This will be indicated by three dashes on the display CORRECT ave RESET 4 SC6 Figure 4 Saving counts on the SC6 Replace the Petri dish with the next and press lt save gt to resume the count Repeat until all dishes have been counted At the end of the run press the lt average gt key to display the average count The average count will be calculated from all previously saved counts The average count may be viewed at any time during the batch counting of Petri dishes by pressing the lt average gt key when the three dashes are visible on the display When the average facility is active a red LED spot at the top left hand corner of the display will be visible Figure 5 Active averaging facility on the SC6 To resume counting press the lt average gt key again When the count is complete press and hold the lt correct reset gt key until the display returns to zero This will clear the memory of saved counts When all counting is completed switch the unit OFF at the mains Turning the audible counting bleep ON or OFF Turn the unit off at the mains ON OFF switch
26. i non autorizzati o da riparazioni effettuate da personale non autorizzato Dati tecnici Display digitale LED a 3 caratteri Conteggio Da 0 a 999 Dimensione della capsula Fino a 90 mm Ingombro dell apparecchio largh x prof x alt 310 x 300 x 140 mm Peso netto 1 5 Kg 13 Espanol Panel de control Posici n de la lupa Placa Ajuste de sensibilidad receptora Interruptor de encendido apagado de alimentaci n Figura 1 Controles de la unidad SC6 Gracias por haber comprado este instrumento Bibby Scientific Si desea aprovechar al m ximo lo que le ofrece el instrumento rogamos lea detenidamente estas instrucciones antes de usarlo Ajuste de fondo Este instrumento ha sido dise ado para funcionar en las condiciones siguientes Lugares a cubierto solamente Zonas bien ventiladas solamente Gama de temperaturas ambientes de 5 C a 40 C Altitud hasta 2000m Humedad relativa no superior al 80 Fluctuaciones del suministro de la red no superiores al 10 Categoria de sobrevoltaje Il IEC60364 4 443 Grado de contaminaci n 2 IEC664 Adaptadores de placa Si el instrumento no se usa de acuerdo como se describe en este manual podr perjudicarse la Figura 2 Parte inferior de la unidad SC6 protecci n que aporta 14 AN Instalacion El ctrica ESTE INSTRUMENTO DEBE SER CONECTADO A TIERRA Antes de efectuar la conexi n por favor asegure que el suministro
27. il hors tension CORRECT SAVE AVERAGE Figure 3 Panneau de commande du SC6 Calcul de moyenne Pour utiliser la fonction de moyenne placez la premi re bo te de P tri sur la plaque r ceptrice A la fin de la num ration appuyez sur la touche lt save gt pour stocker la num ration dans la m moire Ceci va tre indiqu par trois tirets sur l afficheur CORRECT SAVE AVERAGE Figure 4 Sauvegarde des num rations sur le SC6 Remplacez la bo te de P tri par la suivante et appuyez sur lt save gt pour reprendre la num ration R p tez l op ration jusqu ce que toutes les bo tes aient t compt es A la fin du cycle appuyez sur la touche lt average gt pour afficher la num ration moyenne La num ration moyenne va tre calcul e partir de toutes les num rations sauvegard es auparavant La num ration moyenne peut tre visualis e tout moment lors du comptage en lot des bo tes de P tri en appuyant sur la touche lt average gt lorsque les trois tirets sont visibles sur l afficheur Lorsque la fonction de moyenne est active un point rouge mat rialis par une DEL est visible dans l angle en haut gauche de l afficheur CORRECT SAVE AVERAGE Figure 5 Fonction de calcul de moyenne active sur le SC6 Pour reprendre le comptage appuyez de nouveau sur la touche lt average gt Lorsque la num ration est termin e appuyez sur la touche lt correct reset gt et maintenez
28. il sur une surface stable et de niveau La molette de commande de sensibilit situ e l arri re de l appareil permet d ajuster la pression n cessaire pour enregistrer un coup Tournez la dans le sens des aiguilles d une montre pour augmenter la sensibilit et dans le sens inverse des aiguilles d une montre pour diminuer la sensibilit Si les colonies a compter sont de petite taille une loupe est disponible comme accessoire Pour la monter vissez le bras porteur souple l emplacement d sign situ en haut de l appareil Ajustez le bras porteur souple jusqu obtenir le grossissement et le champ de vision voulus Mettez l appareil sous tension l aide de l interrupteur Marche Arr t situ l arri re de l appareil Comptage Positionnez la bo te de P tri sur la plaque r ceptrice l aide de l adaptateur de centrage si n cessaire V rifiez que l afficheur est r gl z ro avant de compter en appuyant sur la touche lt correct reset gt et en la maintenant enfonc e Marquez chaque colonie l aide d un crayon feutre Chaque fois q une colonie est marqu e l appareil enregistre le coup avec un bip et une avance du compteur Si des coups involontaires sont r alis s ils peuvent tre retir s de l afficheur en appuyant sur la touche lt correct reset gt une fois par coup Une fois la num ration termin e r glez l afficheur sur z ro l aide de la touche lt correct reset gt ou mettez l appare
29. m man die Taste lt average gt dr ckt wenn die drei Balken auf dem Display erscheinen Bei aktivierter Durchschnittsfunktion wird dies durch eine rote LED oben links auf dem Display angezeigt 21 Abbildung 5 Aktivierte Durchschnittsfunktion auf dem SC6 Der Zahlvorgang wird durch erneutes Driicken der Taste lt average gt wieder aufgenommen Am Abschluss der Z hlung die Taste lt correct reset gt gedr ckt halten bis sich das Display auf Null zur ck stellt Dadurch wird der Speicher gel scht Nach Abschluss aller Z hlvorg nge das Ger t abschalten Akustisches Signal ein oder ausschalten Das Ger t mit dem ON OFF Schalter ausschalten Die Taste lt save gt gedr ckt halten und das Ger t mit dem ON OFF Schalter einschalten Mit der Taste lt correct reset gt entweder ON oder OFF wahlen Zur Bestatigung die Taste lt average gt drucken Das Koloniez hlger t ist nun einsatzbereit Um das akustische Signal wieder einzuschalten wiederholen Sie die Schritte 1 bis 5 Reinigen der Receiver Platte Die Receiver Platte kann zum Reinigen leicht herausgenommen werden Dazu sicherstellen dass das Ger t vom Netz getrennt ist Den Kolonienz hler nach unten kippen so dass die Platte herausgenommen werden kann Die Platte darf nur mit einem feuchten Tuch gereinigt werden Nach der Reinigung muss die Platte wieder in den Kolonienz hler eingesetzt werden Es sind Ersatzplatten erh ltlich siehe Abschnitt
30. pteur secteur Marche Arr t Figure 1 Commandes du SC6 R glage du fond Merci d acheter ce produit de Bibby Scientific Pour obtenir le bon fonctionnement de l quipement et pour votre s curit lire avec attention les instructions ci dessous avant l utilisation Le mat riel Bibby Scientific est con u pour fonctionner dans les conditions suivantes Pour l usage en int rieur seulement Utilisation dans une pi ce bien a r e Temp rature ambiante 5 C 40 C Altitude inf rieure 2000m Humidit relative n exc dant pas 80 Fluctuations de l alimentation lectrique n exc dant pas 10 de la valeur nominale Cat gorie Il IEC60364 4 443 de surtension Degr 2 IEC664 de pollution Adaptateurs pour bo tes Si l quipement n est pas utilis de la fa on d crite dans ce manuel les diff rentes fonctions Figure 2 Sous face du SC6 de l appareil peuvent tre alt r es AN Installation lectrique CET EQUIPEMENT DOIT ETRE RELIE A LA TERRE Avant le raccordement s assurer que l alimentation lectrique convient Cet appareil exige une alimentation 230V 50 60Hz monophas La puissance est de 22W Une embase CEE est situ e l arri re de l instrument pour le raccordement l alimentation lectrique L instrument est fourni avec deux c bles secteur quip s d une prises CEE pour le raccordement l instrument Sur un se trouve une prise aux normes anglaise
31. quando si ottengono l ingrandimento e il campo visivo ottimali Accendere l apparecchio agendo sull interruttore di accensione ON OFF posto sul retro dell apparecchio Conteggio Sistemare la capsula Petri sul piano di appoggio servendosi eventualmente del riduttore di centraggio Verificare che il display sia stato azzerato prima di procedere al conteggio delle colonie premendo e tenendo premuto il tasto lt correct reset gt Marcare le singole colonie con un pennarello Ogni volta che viene marcata una colonia l apparecchio ne registra il numero attivando un segnale acustico e incrementando il numero visualizzato sul display In caso di errori di conteggio possibile cancellare dal display i conteggi errati premendo una volta il tasto lt correct reset gt per ogni conteggio Una volta ultimato il conteggio azzerare il display agendo sul tasto lt correct reset gt o spegnere l apparecchio AVERAGE Figura 3 Quadro di comando del contacolonie SC6 Calcolo della media Per utilizzare la funzione di calcolo della media sistemare la prima capsula Petri sul piano di appoggio Al termine del conteggio premere il tasto lt save gt per memorizzare il conteggio Appaiono tre lineette sul display CORRECT SAVE AVERAGE Figura 4 Memorizzazione dei conteggi sul contacolonie SC6 Sostituire la capsula Petri con quella successiva e premere lt save gt per ripristinare il conteggio delle colonie Ripetere l
32. raci n o recambio de piezas DEBERA ser realizado por personal capacitado a nivel profesional Recambios y accesorios Los repuestos y accesorios siguientes podr obtenerlos a trav s de su concesionario de productos de laboratorio habitual Descripci n N mero de cat logo Lente de 1 7 aumentos SC6 1 Lente de 3 aumentos SC6 1 3 Reticula Wolffhuegel y disco de segmentaci n paquete de 10 SC6 2 Adaptador de centrado paquete de 2 SC6 3 Discos de protecci n transparentes paquete de 10 SC6 4 Placa receptora SC6 5 Para obtener una lista completa de las piezas necesarias por los ingenieros de mantenimiento que realicen reparaciones internas p ngase en contacto con el Departamento de Ventas en Bibby Scientific Ltd indicando el modelo y el n mero de serie Solamente deber n ser usadas piezas de repuesto suministradas o especificadas por Bibby Scientific Ltd o sus agentes autorizados La instalaci n de piezas no aprobadas puede afectar el buen funcionamiento y las caracter sticas de seguridad inherentes en el instrumento 17 En caso de dura por favor p ngase en contacto con Departamento de Servicio T cnico de Bibby Scientific Ltd o con el agente de venta Afora S A Calle Aribau 240 08006 Barcelona Spain Tel 343 93 306 98 00 Fax 343 93 306 98 23 e mail marketing afora com www afora com Garantia Bibby Scientific Ltd garantiza que este equipo esta libre de defectos en el material y la f
33. rasparenti confezione da 10 pezzi SC6 4 Piastra di ricevimento SC6 5 Per richiedere l elenco completo dei ricambi necessari per eseguire gli interventi di riparazione in sede contattare l ufficio commerciale della Bibby Scientific Ltd citando il modello e il numero di matricola dell apparecchio Si devono usare solo parti fornite o specificate dalla Bibby Scientific Ltd o dai suoi rappresentanti Il montaggio di parti non omologate pu ridurre le prestazioni e le funzioni di sicurezza intese alla progettazione dello strumento In caso di dubbio porsi in contatto con l Ufficio d assistenza tecnica della Bibby Scientific Ltd o il punto di vendita Bibby Scientific Italia Srl Via Alcide de Gasperi 56 20077 Riozzo di Cerro al Lambro Milano Italia Tel 39 0 2 98230679 Fax 39 0 2 98230211 e mail marketing bibby scientific it www bibby scientific it Garanzia Bibby Scientific Ltd garantisce che questo strumento privo di difetti di materiale e fabbricazione per un periodo di tris 3 anni se utilizzato nelle normali condizioni di laboratorio Di fronte a una richiesta giustificata Bibby Scientific sostituir gratuitamente gli eventuali componenti difettosi o tutta l unit La presente garanzia NON si applica per danni provocati da incendio incidente uso improprio negligenza messa a punto o riparazione scorretta danni provocati dall istallazione l adattamento la modifica l inserimento di component
34. re ST15 OSA United Kingdom Tel 44 0 844 936 0234 Fax 44 0 844 936 0235 e mail info bibby scientific com www bibby scientific com Garantie Bibby Scientific Ltd gew hrleistet die einwandfreie Material und Herstellungsqualitat dieses Instruments bei Verwendung unter normalen Laborbedingungen ber einen Zeitraum von drei 3 Jahren Im Fall einer berechtigen Reklamation ersetzt Bibby Scientific die defekte Komponente n bzw das Ger t kostenfrei Diese Garantie gilt NICHT falls der Schaden durch Feuer Unfall unsachgemaBe Verwendung Fahrl ssigkeit inkorrekte Einstellung oder Reparatur sowie durch Installation Anderung Modifikation Anbringen nicht zul ssiger Teile oder Reparatur durch unbefugtes Personal entstanden ist Technische Daten Digitalanzeige 3 stelliges LED Display Z hlung 0 bis 999 Schalengr Be Bis zu 90 mm Abmessungen B x T x H 310 x 300 x 140 mm Nettogewicht 1 5 kg 23 Notes These products meet the relevant EC harmonised standards for radio frequency interference and may be expected not to interfere with or be affected by other equipment with similar qualifications We cannot be sure that other equipment used in their vicinity will meet these standards and we cannot guarantee that interference will not occur in practice Where there is a possibility that injury damage or loss might occur if equipment malfunctions due to radio frequency interference or for general advice before
35. s bo tes de 50 90mm Une loupe est disponible comme accessoire pour compter les tr s petites colonies Conseil de s curit avant utilisation l appareil devra tre port deux mains Ne jamais d placer ou transporter l appareil lorsqu il est en service ou branch l alimentation lectrique sur secteur Dans le cas d une coupure secteur d un d faut ou d une panne lectrique l appareil va continuer fonctionner une fois le probl me r solu Commandes La Figure 1 pr sente les commandes du SC6 La Figure 2 montre la sous face de l appareil Fonctionnement Configuration du compteur de colonies SC6 Pour s lectionner le fond sombre ou blanc faites coulisser le panneau qui se trouve au dessous de l appareil sur la gauche ou sur la droite jusqu ce que le fond se verrouille d un clic en position Pour utiliser une bo te de P tri de moins de 90mm de diam tre s lectionnez l adaptateur appropri qui se trouve galement en sous face de l appareil et placez le sur la plaque r ceptrice Le SC6 est livr avec un paquet de disques translucides con us pour prot ger la plaque r ceptrice de la poussi re et des rayures Placez un disque sur la plaque r ceptrice S il est endommag retirez le et remplacez le par un autre Si le r ticule de Wolffhuegel ou le disque de segmentation est n cessaire placez le sur le dessus du disque protecteur translucide sur la plaque r ceptrice Positionnez l appare
36. s et sur l autre une prise de europ en 2P T Choisir le c ble appropri pour votre installation lectrique et jeter l autre Si ni l un ni l autre ne conviennent vous devrez alors obtenir le bon c ble localement Si ce n est pas possible prendre celui avec la prise anglaise la couper et la remplacer par celle correspondante au pays d utilisation Voir la feuille d instruction incluse pour le montage de cette prise Si l tat du c ble secteur exige son remplacement un c ble de 1mm norme HO5W F reli une prise CEE 320 devra tre employ N B Le c ble anglais est prot g par un fusible 10A mont dans la prise Le c ble doit tre reli l instrument AVANT le raccordement l alimentation lectrique EN CAS DE DOUTE CONSULTER UN LECTRICIEN QUALIFI Description g n rale L appareil consiste en une plaque r ceptrice clair e et un grand afficheur diodes lectrolu minescentes La pression de marquage d une colonie avec un crayon feutre enregistre un coup par un bip sonore et l avance sur un afficheur num rique Une fonction de moyenne incorpor e 6 permet de compter de multiples plaques puis de calculer la num ration moyenne des colonies La pression n cessaire pour enregistrer un coup peut tre ajust e Le choix est disponible entre fond clair et fond noir et l appareil est livr avec un r ticule de Wolffhuegel un disque de segmentation et des adaptateurs de centrage pour de
37. te contar multiples placas y luego calcular el promedio del recuento de colonia Se puede ajustar la presi n necesaria para registrar un recuento Se puede elegir entre un fondo claro o negro y la unidad se suministra con una cuadricula Wolffhuegel un disco de segmentaci n y adaptadores de centrado para platos de 50 90 mm Existe disponible a modo de accesorio una lupa para contar colonias muy peque as Consejos de seguridad antes del uso La unidad se debe llevar con las dos manos lt Nunca mueva o transporte la unidad cuando est en uso o conectada al suministro el ctrico principal lt En caso de una interrupci n del suministro el ctrico una aver a o un fallo el ctrico la unidad seguir funcionando cuando se solucione el fallo Controles La Figura 1 muestra los controles de la unidad SC6 La Figura 2 muestra la parte inferior de la unidad Funcionamiento Configuraci n del contador de colonias SC6 Para seleccionar el fondo oscuro o blanco deslice hacia la izquierda o derecha el panel situado en la parte inferior de la unidad hasta que el fondo se acople en la posici n inicial Para utilizar una placa de cultivo de un di metro inferior a 90 mm seleccione el adaptador correspondiente que tambi n se puede encontrar en la parte inferior de la unidad y sit elo en la placa receptora La SC6 incluye un paquete de discos claros dise ados para proteger la placa receptora del polvo y los ara azos
38. te einschalten Z hlvorgang Die Petrischale auf den Z hlteller setzen ggf Adapter verwenden Darauf achten dass das Display auf Null gesetzt ist Hierzu die Taste lt correct reset gt Korrektur R cksetzen gedr ckt halten Alle Kolonien mit einem Filzstift markieren Bei jeder Markierung wird ein akustisches Signal ausgegeben und der Z hler erh ht Versehentliche Z hlungen k nnen durch jeweils einmaliges Dr cken der Taste lt correct reset gt gel scht werden Nach Abschluss der Z hlung entweder das Display durch Dr cken der Taste lt correct reset gt auf Null setzen oder das Ger t ausschalten Abbildung 3 SC6 Bedienfeld Durchschnittsfunktion Zum Einsatz der Durchschnittsfunktion zuerst die Petrischale auf den Z hlteller setzen Am Ende der Z hlung die Taste lt save gt Speichern dr cken um den Z hlwert zu speichern Dies wird mit drei Balken auf dem Display angezeigt CORRECT ave RESET a SC6 Abbildung 4 Z hlwertspeicherung auf dem SC6 Nun die n chste Petrischale aufsetzen und erneut auf lt save gt dr cken um die Z hlung fortzusetzen Diesen Vorgang wiederholen bis alle Schalen gez hlt worden sind Ganz am Schluss die Taste lt average gt Durchschnitt dr cken um den Durchschnittswert zu erhalten Der Durchschnittswert wird aus den vorhergehenden abgespeicherten Z hlungen berechnet Der Durchschnittswert kann auch w hrend der Z hlung abgelesen werden inde
39. use please contact the Technical Service Department of Bibby Scientific Ltd standards Control and Laboratory use Control and Laboratory use Compliance Certificates and Full Reports Ref RETS0620 A 1 and RETS0620 A 2 CE mark affixed 03 DofC_43_Rev02 Declaration of Conformity Colony Counter Models SC6 SC6 100V 50 SC6 100V 60 SC6 120V 60 C6 220V 50 SC6 220V 60 These products comply with the requirements of the EU Directives listed below 89 336 EEC Electromagnetic Compatibility Directive amended by 93 68 EEC 73 23 EEC Low Voltage Directive amended by 93 68 EEC Compliance with the requirements of these Directives is claimed by meeting the following EN 61326 1997 Amendments A1 1998 Electrical Equipment for Measurement EN61010 1 2001 Safety Requirements for Electrical Equipment for Measurement From Epsilon Technical Services an Independent Accredited Test House showing compliance to the above standards are available on request Signed Mr D E Hicks Authority Technical Development Manager for Barloworld Scientific Ltd Stone Staffs ST15 OSA UK Tel 44 0 1785 812121 Fax 44 0 1785 813748 INSPECTION REPORT MODEL SC6 ELECTRICAL SAFETY 1 Earth continuity 2 Insulation 3 Flash test FUNCTIONAL 1 Indicators 2 Counting function 3 Visual acceptance QUALITY CONTROL INSPECTOR O O Q O O RS Bibby S