1. 0 5 10 15 20 25 30 35 40 45 50 55 60 Battery temperature 3 6 3 Remote Control panel amp remote on off switch The product can be operated remotely in two ways Use of only an external switch With the aid of a remote control panel Observe the following when using only an external switch Only functions if the switch on the product is switched to the on position Not to be connected if a remote control is connected Observe the following when using a remote control Only functions if the switch on the product is switched to the on position 3 6 4 External Alarm Relay and Virtual Switch An open collector output is available to connect a relay that can be used for remote alarm and other purposes a o generator start signal The maximum voltage current that can be switched open collector transistor 66V 40mA The open collector output can be programmed with VEConfigure victron energy 13 Gul y 4 SETTINGS Settings may only be changed by a qualified engineer Carefully read the instructions before changes are made Batteries should be placed in a dry and well ventilated area during charging 4 1 Default Settings Inverter Voltage 230 Vac Charger on off on Charge curve Adaptive charging gel cell Charging Current 75 of maximum charging current Absorption Voltage 14 4V 28 8V 57 6 Vdc Absorption Time Maximum Absorption Time 4 hours Float Voltage 13 8V 27 6V 55 2 Vdc Repeated Absorpt
2. Pour le raccordement du tableau de commande distance voir appendice A Si un tableau de commande distance est install tenir compte des indications suivantes N est op rationnel que si le commutateur de l appareil est sur on 3 6 4 Relais d Alarme externe et Commutateur Virtuel Une sortie collecteur ouvert est disponible pour raccorder un relayer un signal d alarme et d autres fonctions par exemple un signal de d marrage pour groupe lectrog ne La puissance maximale transistor collecteur ouvert est de 66V 40mA Les fonctions de la sortie collecteur ouvert sont param trables l aide de VEConfigure victron energy 15 Gul y 4 REGLAGES Lire attentivement les instructions avant toute modification La modification des r glages doit tre effectu e par un technicien qualifie Le batteries doivent tre install es dans un lieu sec et bien ventil pendant la charge 4 1 R glages par d faut usine Tension du convertisseur Chargeur on off Caract ristiques de Charge batteries au gel Courant de Charge 230 Vac on Charge Adaptative 75 du courant maxi Tension Absorption 14 4 28 8 57 6 Vdc Dur e d absorption Dur e d absorption maxi 4 heures Tension Float 13 8 27 6 55 2 Vdc Dur e d Absorption R p t e 1 heure Intervalle d absorption R p t e 7 jours Protection Bulk on AC Waveform Check on PowerAssist MultiPlus uniquement on Limite de courant d en
3. 38 0 64 4 bereich V 9 5 16 1 19 0 32 2 Mindesteinschalt 10 9 218 43 6 spannung IN Untere Ausschalt 9 0 18 0 56 spannung V Obere Ausschalt 16 1 32 2 64 4 spannung V Brummspannung V Max 1 25V effektiv effektiv Eingangsnennstrom 65 100 130 35 50 65 25 35 A Eingangsstrom 85 130 170 40 65 85 30 40 Maximal A Eigenverbrauch W 8 8 8 12 12 12 15 15 Spar Modus 5 5 5 9 9 9 12 12 Gleichstromeingangs 200 250 250 80 200 200 150 150 sicherung A Ausgangsspannung V 230 1 Ausgangsspan 185 245 nungsbereich V Frequenz Hz 50 60 0 01 quartzstabilisiert Ausgangsspan Reine Sinuswelle nungsform Klirrfaktor Max 5 Leistungsfaktor F r alle Verbraucher Sparmodus DS5 on Last lt 25W 145V Max 300V Speziell angepasst f r SL PL und R hren Lampen nominale Helligkeit und Uhren Nicht lineare Last Scheitelfaktor 3 1 VA 25 C 800 1200 1600 800 1200 1600 1200 1600 Nennleistung W cos 9 1 0 25 C 650 1000 1300 650 1000 1300 1000 1300 Nennleistung W cos 9 1 0 40 C 600 900 1100 600 900 1100 900 1100 Einschaltleistung W 1900 2000 2300 1900 2600 3000 2600 3000 Einschaltverhalten Die nominale Ausgangsspannung wird innerhalb 20 ms erreicht Wirkungsgrad bei Nennleistung 87 86 84 88 87
4. 86 87 86 Wirkungsgrad bei Ye Nennleistung 90 88 87 90 89 87 90 88 Ausgangskurz schlussstrom 10 12 13 10 12 13 13 15 victron energy N y 27 6 3 Lader 12 1200 150 12 800 135 12 1600 170 24 800 16 24 1200 125 24 1600 140 48 1200 112 48 1600 20 Eingangsspannung V 200 250 Ausschaltspannung V lt 180 und gt 270 Frequenz Hz 45 55 or 55 65 Maximaler Eingangstrom A Bei 230 V Eingangsspannung keine Verbraucher am Ausgang 2 7A 3 9A 5 6A 2 5A 3 8A 6 3A Eingangssicherung sautomat 250 V 16A 16A 16A 16A 16A 16A 16A 16A Wirkungsgrad 84 82 81 85 84 83 85 84 Cos q Leistungsfaktor 1 0 Absorptions spannung Grundeinstellung V 14 4 28 8 57 6 Ladeerhaltungs spannung Grundeinstellung V 13 8 27 6 55 2 Ausgangs spannungsbereich V Min max 8 16 11 32 22 64 Ladecharakteristik Adaptive 4 Stufenladung Startbatterien ennstrom A 4 Erlaubte Brummspannung V effektiv Max 1 25 Batterieleckstrom bei ausgeschaltetem Ger t mA lt 1mA 28 victron energy N y 6 4 Umschaltautomat Durchgeschaltete Spitzenleistung W 6900W begr
5. 200 150 150 Tensi n de salida VCA 230 1 Rango de tensi n de salida VCA 185 245 Frecuencia Hz 50 60 0 01 cuarzo Tensi n de salida Sinusoidal pura THD Max 5 Factor de potencia Todas las cargas Ahorro DS6 on potencia lt 145VAC cresta 300V especialmente adaptado para l mparas SL PL y ne n luminosidad nominal y 25W relojes Carga no lineal 800 1200 1600 800 1200 1600 1200 1600 factor de cresta 3 1 VA 25 C Potencia nominal 650 1000 1300 650 1000 1300 1000 1300 W cos 1 0 25 C Potencia nominal 600 900 1100 600 900 1100 900 1100 W cos 1 0 40 C Corriente de 1900 2000 2300 1900 2600 3000 2600 3000 irrupci n W Respuesta ala Tensi n nominal de salida en 20 mS puesta en marcha Rendimiento a la 87 86 84 88 87 86 87 86 Pnom Rendimiento a 90 88 87 90 89 87 90 88 Y Pnom Corriente de 10 12 13 10 12 13 13 15 cortocircuito victron energy O y 25 6 3 Cargador 12 800 12 1200 12 1600 24 800 24 1200 24 1600 48 1200 48 1600 135 150 170 116 125 40 112 20 Tensi n de entrada VCA 200 250 L mites de apagado Vac lt 180 en gt 270 Frecuencia Hz 45 55 de 55 65 Corriente m xima de entrada A La tensi n de red de entrada es de 230 Vac sin consumo CA a la salida 2 7A
6. AC in aansluiting spanning wordt aangesloten zal deze na controle en goedkeur worden doorgeschakeld naar de AC out aansluiting De omvormer wordt uitgeschakeld de gele LED charger zal branden en de lader treedt in werking Afhankelijk van de laadmode die op dat moment van toepassing is zal de gele LED branden bulk en of absorption of de gele LED knippert float Als de spanning op de AC in aansluiting wordt afgekeurd zal de omvormer worden ingeschakeld Wanneer de schakelaar op charger only wordt gezet zal alleen de acculader van de Phoenix Multi Compact aanschakelen indien er netspanning aanwezig is Deze spanning wordt doorgeschakeld naar de AC out aansluiting TIP Als u uw Phoenix Multi Compact gebruikt op een schip zorg er dan voor dat als u het schip verlaat de schakelaar in de positie charger only wordt gezet Hiermee voorkomt u dat bij het wegvallen van de netspanning de omvormer inschakelt en uw accu s leeg raken 2 2 Afstandsbediening De Phoenix Multi Compact kan optioneel met het Phoenix Multi Control paneel worden bediend Met dit paneel kunt u status en of alarmen van Multi Compact aflezen Omdat de beschikbare walstroom vaak beperkt is kan men met het paneel de maximale laadstroom instellen De Phoenix Multi Compact beperkt het eigen verbruik voor het laden wanneer de totale walstroom over het ingestelde maximum dreigt te gaan Het laadgedeelte van de Phoenix Multi Compact kan buiten
7. Opslaan druk schakelaar DS 8 naar on en weer terug naar off De instelling van DS7 is nu actief N y victron energy 17 4 3 De adaptive charging laad curve Charge current 120 100 80 Amps 60 40 20 0 Volts H i Charge voltage 16 H i 64 32 Battery Safe 45 mode 14 20 x Bulk uren of i Max Absorption time 13 60 30 12 11 10 56 28 Time Bulk uren Absorptie 1 dag 7 dagen 7 dagen float reduced float reduced ee 1 uur Repeated Absorption 4 laad karakteristieken Bulk mode Eerste deel van de laadcurve Constante stroom wordt toegevoerd tot de gasspanning wordt bereikt 14 4V resp 28 8V temperatuur gecompenseerd Battery Safe Mode Indien om de laadtijd te verkorten gekozen wordt voor een hoge laadstroom en ook een verhoogde laadspanning dan zal de Phoenix Multi Compact MultiPlus Compact nadat de gasspanning bereikt is de stijgsnelheid van de spanning begrenzen Zo wordt overmatig gassen voorkomen Absorptie mode De accu wordt met een constante spanning geladen De absorptie tijd is 20x de bulk tijd tenzij de ingestelde maximum absorptie tijd wordt bereikt Float mode Float spanning wordt toegevoerd om de accu volledig geladen te houden Reduced Float Na een dag Float laden wordt overgeschakeld naar reduced Float Deze is 13 2V resp 26 4V voor 12V en 24V laders Dit voorkomt water verlies tot een
8. on staan en dat er niet een schakelaar op de stand charger only staat Om de Phoenix Multi Compact in deze toestand te brengen dient u de stappen te volgen zoals hierna beschreven LET OP het omschakelen van on naar charger only en andersom zoals hieronder beschreven dient op een snelle manier te gebeuren De schakelaar moet zodanig omgeschakeld worden dat de middenstand als het ware overgeslagen wordt Als de desbetreffende schakelaar ook maar even in de stand off blijft staan loopt u het risico dat het apparaat uitgezet wordt In dat geval dient u weer bij stap 1 te beginnen Met name bij gebruik van de front schakelaar is enige oefening gewenst Bij gebruik van het remote control is dit geen probleem 1 Let erop dat alle schakelaars dus front schakelaar remote schakelaar of remote control schakelaar voor zover aanwezig in de stand on staan 2 Zorg ervoor dat de Phoenix Multi Compact laadt Er dient dus een AC ingangsspanning te zijn controleer of de gele LED charger branat 3 Zet de schakelaar achtereenvolgens op charger only on en charger only Let op het omschakelen zelf moet snel gebeuren maar de tijd tussen het omschakelen moet liggen tussen 1 2 seconde en 2 seconden 4 De groene LED on bulk gele LED charger absorption en rode LED alarm float LED zullen nu 5 keer knipperen Daarna zullen achtereenvolgens de bulk absorption en float
9. LUE POWER My victron energy Manual Handleiding ME Manuale Anleitung Manual DOI EN EN EN Phoenix Multi Compact 12 800 35 24 800 16 12 1200 50 24 1200 25 48 1200 12 12 1600 70 24 1600 40 48 1600 20 Phoenix MultiPlus Compact 12 1200 50 24 1200 25 12 1600 70 24 1600 40 48 1600 20 Phoenix MultiPlus Compact 12 1200 24 1200 12 1600 24 1600 48 1600 Copyrights O 2008 Victron Energy B V All Rights Reserved This publication or parts thereof may not be reproduced in any form by any method for any purpose For conditions of use and permission to use this manual for publication in other than the English language contact Victron Energy B V VICTRON ENERGY B V MAKES NO WARRANTY EITHER EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE REGARDING THESE VICTRON ENERGY PRODUCTS AND MAKES SUCH VICTRON ENERGY PRODUCTS AVAILABLE SOLELY ON AN AS IS BASIS IN NO EVENT SHALL VICTRON ENERGY B V BE LIABLE TO ANYONE FOR SPECIAL COLLATERAL INCIDENTAL OR CONSEQUENTIAL DAMAGES IN CONNECTION WITH OR ARISING OUT OF PURCHASE OR USE OF THESE VICTRON ENERGY PRODUCTS THE SOLE AND EXCLUSIVE LIABILITY TO VICTRON ENERGY B V REGARDLESS OF THE FORM OF ACTION SHALL NOT EXCEED THE PURCHASE PRICE OF THE VICTRON ENERGY PRODUCTS DESCRIBED HERE IN Victron Energy B V reserves the right to revise a
10. 3 9A 5 6A 2 5A 3 8A 6 3A Fusible de entrada TCB 250 Vac 16A 16A 16A 16A 16A 16A 16A 16A Rendimiento 84 82 81 85 84 83 85 84 Cos q factor de potencia 1 0 Tensi n de carga de absorci n por defecto VCC 14 40 28 80 Tensi n de carga de flotaci n por defecto VCC 13 80 27 60 Tensi n de carga de salida VCC Min max 8 16 11 32 Caracteristicas de carga 4 etapas variable Corriente nominal de bater a de arranque A 4 Ondulaci n de tensi n m xima CC Vrms Max 1 25 Fuga de corriente con el inversor parado mA lt 1mA 26 victron energy N y 6 4 Conmutador de entrada CA Potencia m xima de CA conmutada 3600 W limitada por un disyuntor t rmico de 16 A Tiempo de conmutaci n entre el inversor y la entrada CA Oms Tiempo de conmutaci n entre la entrada CA y el inversor Oms Bateria gt 10 5 V Tiempo de detecci n de un fallo en la entrada CA 4 ms a 20 ms Tensi n de conmutaci n de red a inversor 180 VCA Tensi n de conmutaci n de inversor a red 187 VCA Rango de frecuencia min max 50 Hz 60 Hz 45 55 Hz 0 55 65 Hz 1 El inversor funciona en paralelo con la entrada CA 6 5 Mecanica 12 800 12 1200 12 1600 24 800 24 1200 24
11. DC Ingangsrimpel te hoog Temperatuur beveiligd transformator Electronic amp Powerstage Batterij als de sensor is aangesloten Relatieve vochtigheid 0 95 EMC Elektromagnetische compatibiliteit volgens EMC richtlijn EMC 89 336 EEC Emissie EN 55014 1993 en EN50081 1 EN61000 3 2 EN61000 3 3 Immuniteit EN 55104 1995 Veiligheid Laagspannings norm 73 23 EEG en 93 68 EEG EN60335 1 en EN60335 2 29 Automotive 95 54 EC 24 victron energy N y 6 2 Omvormer 12 800 12 1200 12 1600 24 800 24 1200 24 1600 48 1200 48 1600 135 50 170 116 125 140 112 120 12 800 12 1200 12 1600 24 800 24 1200 24 1600 48 1200 48 1600 Ingangsspanning a 38 0 64 4 bereik Vdc 9 5 16 1 19 0 32 2 Inschakelspanning 43 6 Vdo 10 9 21 8 Uitschakel 56 spanninglaag Vdc 9 0 18 0 Uitschakel spanning 64 4 hoog Vdc 16 1 32 2 rimpelspanning Max 1 25Vrms Vrms Ingangsstroom 65 100 130 35 50 65 25 35 Nominaal A Ingangsstroom 85 130 170 40 65 85 30 40 Maximaal_ A Vermogens verbruik 8 8 8 12 12 12 15 15 onbelast W Economy 5 5 5 9 9 9 12 12 DC veiligheids 200 250 250 80 200 200 150 150 zekering A Output Vac 230 1 Output Voltage 185 245 Range Vac Frequentie Hz 50 60 0 01 kristal Uitgangs spanning Pure sinewave THD Max 5 Arbe
12. LED elk gedurende 2 seconden branden Indien de schakelaar tijdens het branden van de LED groen bulk naar on gezet wordt wordt de lader in Equalizing gezet Indien de schakelaar tijdens het branden van de LED geel absorption naar on gezet wordt wordt de lader in Forced Absorption gezet Indien er niet geschakeld wordt in voorgaande lader gaat over op float mode Indien na deze stappen de schakelaar niet in de gewenste positie staat on kan de schakelaar eenvoudig nog eenmaal snel omgeschakeld worden naar charger only Dit zal de laadtoestand niet wijzigen 6 AD y victron energy 2 4 LED aanduidingen O LED uit X LED knippert O LED brandt Omvormer Omvormer inverter O on charger O off alarm O charger only inverter O on charger O off alarm TE charger only inverter O on charger O off alarm charger only Batterij bedrijf De omvormer staat aan en levert vermogen aan de belasting De omvormer is ingeschakeld en levert vermogen aan de belasting Voor alarm overbelasting of accu spanning te laag of omvormer temperatuur hoog De omvormer is uitgeschakeld Alarm overbelasting of accu spanning te laag of omvormer temperatuur te hoog of DC rimpelspanning was te hoog slechte verbinding victron ener A y K ES Acculader inverter on charger J i off alarm O cha
13. bis der Verbraucherstrom das 1 5 fache der Eingangsstrombegrenzung erreicht hat Grund daf r ist dass sich der Inverter nicht unn tig einschaltet wenn ein gro er Verbraucher eingeschaltet wird und die Eingangsspannung dadurch kurzzeitig einbricht PowerControl Arbeiten mit begrenzter Generatorleistung oder eingeschranktem Landstrom nur Phoenix Multi Compact MultiPlus Compact Der Phoenix Multi Compact MultiPlus Compact verf gt ber ein Batterieladeger t mit hoher Leistung Deshalb zieht er eine Menge Strom vom Generator oder Landanschluss fast 5 A am 230 V Netz Mit dem Phoenix Multi Control kann der maximal zu entnehmende Netz bzw Generatorstrom eingestellt werden Der Phoenix Multi Compact Multi Plus Compact nimmt dann R cksicht auf weitere angeschlossene Stromverbraucher und nutzt zum Laden nur den Strom der noch brig ist So wird verhindert dass der Generator oder der Landstromanschluss berlastet wird Der Generator Landanschlussstrom kann zwischen 2 und 30 A eingestellt werden Die Einstellungen am Phoenix Multi Control Panel berschreiben die internen Einstellungen PowerAssist Leistungssteigerung von Generatoren und Landanschlussunterst tzung Dieses Leistungsmerkmal unterscheidet den Phoenix Multi Plus Compact vom Multi Compact Mit dieser Funktion erh lt das Prinzip der Netzkontrolle eine neue Dimension da der Multi Plus Compact jedes zu schwach ausgelegte Netz st tzt Damit kann wenn hoher S
14. ble 3 conducteurs pour les raccordements AC 3 4 Raccordement des c bles de batterie Pour b n ficier de la puissance maximale de l appareil il faut l utiliser avec des c bles de section suffisante et des batteries de capacit suffisante Voir tableaux 24 800 24 1200 12 800 12 1200 12 1600 Mod le 48 1600 24 1600 48 1200 Section minimale des c bles batterie mm 1 5 5 m tres 16 25 35 50 70 5 10 m tres 35 50 70 100 140 1 1 5 m mont en standard sur les appareils 24 800 24 1200 12 800 12 1200 12 1600 Mod le 48 1600 24 1600 48 1200 Capacit de batterie 40 299 40 400 100 400 150 700 200 700 recommand e Ah Remarque la r sistance interne est d terminante si vous utilisez des batteries de petite capacit Consultez votre fournisseur ou les chapitres correspondants dans notre livre I Electricit Bord en t l chargement libre sur notre site Web Proc dure Pour le raccordement des c bles de batterie proc dez comme suit IN Voir appendice Raccorder le c ble rouge gauche au batterie Raccorder la c ble noir droite au batterie Une inversion de polarit pourra endommager l appareil fusible de s curit interne Serrer fortement les raccordements pour r duire les partes de tension sur les connections Danger de courts circuits Utilisez exclusivement des outils isol s Ne pas mettre les c ble
15. en uso modo Almacenamiento El modo de almacenamiento se activa cuando la bater a no ha sufrido ninguna descarga en 24 horas En el modo de almacenamiento la tensi n de flotaci n se reduce a 2 2 V acumulador 13 2 V para bater as de 12 V para reducir el burbujeo y la corrosi n de las placas positivas Una vez a la semana se vuelve a subir la tensi n a nivel de absorci n para igualar la bater a Esta funci n evita la estratificaci n del electrolito y la sulfataci n las causas principales de los fallos en las bater as Dos salidas para cargar 2 bancadas de bater as El Multi Compact MultiPlus Compact dispone de 2 salidas de las cuales 1 puede suministrar toda la corriente de salida La segunda salida limitada a aproximadamente 4 A y con una tensi n de salida ligeramente m s baja est pensada para mantener una bater a de arranque Para una mayor duraci n de la bater a compensaci n de temperatura Los Multi Compact MultiPlus Compact se suministran con un sensor de temperatura de la bater a Al conectarlo la tensi n de carga disminuir autom ticamente a medida que aumente la temperatura de la bater a Esta funci n se recomienda especialmente para bater as selladas y o cuando se esperan grandes fluctuaciones de temperatura en la bater a Aprenda m s sobre bater as y cargas Para saber m s sobre bater as y sobre c mo cargar las mismas le rogamos consulte nuestro libro Electricidad a Bordo disp
16. lo funcionar el cargador de bater a del Phoenix Multi Compact si dispone de tensi n de la red En este modo la tensi n de entrada tambi n se conmuta al terminal de salida AC out NOTA Cuando s lo necesite la funci n de carga aseg rese de que el conmutador est en charger only Esto har que no se active el inversor si se pierde la tensi n de la red evitando as que sus bater as se queden sin carga 2 2 Control remoto El Phoenix Multi Compact puede controlarse desde el panel denominado Phoenix Multi Control El control remoto tiene un conmutador de encendido apagado y los LED del aparato La funci n de cargador del Phoenix Multi Compact puede desactivarse Esto puede hacerse cambiando la configuraci n y conectando el control remoto del Phoenix Inverter ajustar la corriente de entrada CA a 0 o conectando un ordenador al Phoenix Multi Compact utilizar MK 1 con VEConfigure Para controlar a distancia el Phoenix Inverter Compact deber utilizarse el panel de control del Phoenix Inverter 2 3 Modos de carga especiales igualaci n Algunas bater as podr an necesitar peri dicamente una carga de igualaci n Para llevar a cabo una carga de igualaci n el Phoenix Multi Compact puede cargar durante un periodo de una hora con una tensi n mayor 1 V por encima de la tensi n de absorci n para una bater a de 12 V y 2 V para una de 24 V La corriente de carga se limita despu s a del valor establecido Du
17. m ximo de absorci n puede establecerse entre 1 y 8 horas Tensi n de flotaci n por defecto 14 4 V 28 8 V La tensi n de flotaci n puede establecerse entre 12 V y 16 V respectivamente desde 24 V a 32 V en incrementos de 0 05 V Absorci n repetida Cuando est en flotaci n el cargador volver peri dicamente a absorci n para refrescar la bater a Tiempo de absorci n repetida por defecto 1 hora El tiempo de absorci n repetida puede establecerse entre 1 y 72 cuartos de hora Intervalo de absorci n repetida por defecto 7 d as El intervalo de absorci n puede establecerse entre 1 y 45 d as victron energy 19 O y 4 5 Ajustes especiales s lo pueden cambiarse con el VEConfigure Protecci n de carga bulk On Off por defecto on Si el cargador no ha alcanzado la tensi n de absorci n despu s de 10 horas de carga en modo bulk puede que la bater a est defectuosa Para evitar da os mayores el cargador se apagar autom ticamente despu s de 10 horas de carga inicial El LED bulk empezar a parpadear Phoenix Inverter Control Comprobaci n de curva de CA por defecto on El Phoenix Multi Compact comprueba no s lo que la tensi n de la red sea la correcta sino tambi n que tenga la forma de curva adecuada Si el Phoenix Multi Compact no funciona correctamente en un generador esta funci n puede desactivarse Nota Adem s al deshabilitar la comprobaci n de curva CA se i
18. on victron energy O y 30 29 28 27 26 25 24 23 22 21 20 Volts 13 3 6 4 Rel de alarma externa y conmutador virtual Hay una salida de colector abierto disponible para conectar un rel que puede utilizarse para una alarma remota y para otras funciones como una se al de arranque del generador La tensi n corriente m xima conmutable transistor de colector abierto 66V 40mA La salida de colector abierto puede programarse con el VEConfigure 14 victron energy n N y 4 AJUSTES Los ajustes s lo puede modificarlos un ingeniero cualificado Lea las instrucciones detenidamente antes de realizar cambios Las bater as deber n colocarse en un lugar seco y bien ventilado durante la carga 4 1 Valores predeterminados Tensi n del inversor 230 VCA Cargador on off on Curva de carga Carga variable bater as de gel Corriente de carga 75 de la corriente de carga m xima Tensi n de absorci n 14 4V 28 8V 57 6 VCC Tiempo de absorci n Tiempo de absorci n m ximo 4 horas Tensi n float 13 8V 27 6V 55 2 VCC Tiempo de absorci n repetida 1 hora Intervalo de absorci n repetida 7 d as Protecci n bulk on Comprobaci n de curva de CA on PowerAssist s lo MultiPlus on Corriente del generador pantal n 12A Frecuencia del sistema Multi Compact MultiPlus Compact Autom tica Inverter Compact 50 Hz AES conmutador de ahorro autom tico off 4 2 Ajustes que pueden c
19. 900 1100 600 900 1100 900 1100 cos 1 0 40 C Inrush power W 1900 2000 2300 1900 2600 3000 2600 3000 Switch on Nominal Output voltage within 20mS behavior efficiency Pnom 87 86 84 88 87 86 87 86 efficiency 90 88 87 90 89 87 90 88 Ye Pnom Short circuit output 10 12 13 10 12 13 13 15 current victron energy Gul y 23 6 3 Charger 12 800 35 12 1200 50 12 1600 70 24 800 16 24 1200 125 24 1600 40 48 1200 112 48 1600 20 Input Voltage VAC 200 250 Switch off limits Vac lt 180 and gt 270 Frequency Hz 45 55 or 55 65 Maximum input current A Main input vo tage is 230 Vac AC no load on outpu 2 7A 3 9A 5 6A 2 5A 3 8A 6 3A Input fuse TBC 250 Vac 16A 16A 16A 16A 16A 16A 16A 16A Efficiency 84 82 81 85 84 83 85 84 Cos q power factor 1 0 Absorption charge voltage default Vdc 14 4 28 8 57 6 Float charge voltage default Vdc 13 8 27 6 55 2 Output charge voltage Vdc Min max 8 16 11 32 22 64 Charge characteristic 4 stage adaptive Nominal start battery current A 4 Maximum DC voltage ripple Vrms Max 1 25 Battery leakage current inverter is switched off mA lt 1mA 24 victron ener
20. AES Automatic Economy Switch off 4 2 Instellingen die met de dipswitches gewijzigd kunnen worden Type Accu Type Absorption spanning Float spanning Maximum absorption tijd 1 Sonnenschein 14 4 V 28 8 V 57 6V 13 8V 27 6 V 55 2V 4 uur standaard Dryfit A200 13 2V 26 4V 52 8V Gel 2 Tractie 15 0 V 30 0V 60 0V 13 8V 27 6 V 55 4V 6 uur buisjesplaat 13 2V 26 4V 52 8V 3 Semi Tractie 14 4 V 28 8V 57 6V 14 0 V 28 0 V 56V 5 uur vlakke plaat 13 2V 26 4V 52 8V 4 Alt 14 8 V 296V 59 2V 14 0 V 28 0 V 56V 5 uur 13 2V 26 4V 52 8V De optimale absorption spanning van vlakke plaat loodzuur accu s hang af van mechanische en chemische eigenschappen Accu s met een hoog antimoon gehalte kunnen in het algemeen geladen worden met een lagere absorption spanning dan accu s met een laag antimoon gehalte Zie het boek Electriciteit aan boord van jachten op www victronenergy com De lader staat standaard afgeregeld voor het laden van gel accu s zoals de Sonnenschein Dryfit A200 accu Vraag bij gebruik van andere Typn accu s aan uw acculeverancier de juiste laadspanningen en laat zonodig de Phoenix Multi Compact hierop met behulp van VEConfigure aanpassen De Laadstroom staat ingesteld op 75 van nominale laadstroom Vaak is dit een te hoge laadstroom De meeste accu s dienen geladen te worden met een stroom van 0 1 tot 0 2x de capaciteit vic
21. Dieses Leistungsmerkmal unterscheidet den Phoenix MultiPlus Compact vom Phoenix Multi Compact Mit dieser Funktion erh lt das Prinzip der Netzkontrolle eine neue Dimension da der Multi Plus Compact jedes zu schwach ausgelegte Netz st tzt Damit kann wenn hoher Strom f r nur kurze Zeit ben tigt wird der Generator eine Nummer kleiner gew hlt und ein eigentlich zu schwach ausgelegter Landstromanschluss gest tzt werden Wird die Last reduziert d h werden Verbraucher ausgeschaltet kann die dann wieder ausreichend vorhandene Energie zum Laden der Batterien genutzt werden Note 1 The rating of the generator should be 75 or higher compared to the VA rating of the MultiPlus Compact for ex a genset of at least 1500 VA will be required to operate in parallel with a Multi Compact 12 2000 80 Note 2 The output waveform of a generator can be heavily distorted In that case the AC waveform check should be disabled victron energy 3 N y 1 2 Ladeger t nur Phoenix Multi Compact MultiPlus Compact Adaptive vierstufige Ladekennlinie Konstantstrom bulk Phase Konstantspannungs absorption Phase Ladeeerhaltungsspannungs float Phase Lagerspannungs storage Phase Das mikroprozessorgesteuerte adaptive Batterie Managementsystem kann auf die unterschiedlichen Batterietypen abgestimmt werden Adaptiv bedeutet dass die Ladekennlinie automatisch der Art der Batterienutzung angepasst wird Die richtige Ladungs
22. Emission EN 55014 1993 en EN50081 1 EN61000 3 2 EN61000 3 3 Immunit EN 55104 1995 S curit Directive basse tension 73 23 EEC et 93 68 EECG EN60335 1 et EN60335 2 29 Directive automobile 95 54 EC 26 victron energy A y 6 2 Convertisseur r glages usine 12 800 12 1200 12 1600 24 800 24 1200 24 1600 48 1200 48 1600 135 150 170 116 125 135 112 120 12 800 12 1200 12 1600 24 800 24 1200 24 1600 48 1200 48 1600 Plage de tension 8 E _ d entr e Vdo 9 5 16 1 19 0 32 2 38 0 64 4 Tension de d marrage Vdc 10 9 21 8 43 6 Tension d arr t basse Vdc 9 0 18 0 56 Tension d arr t 16 1 32 2 64 4 haute Vdc Ondulation de tension Vrms 1 25Vrms maxi Courant d entr e 65 100 130 35 50 65 25 35 nominal A Courant d entr e maxi A 85 130 170 40 65 85 30 40 Consommation a vide W 8 8 8 12 12 12 15 15 ik Economy 5 5 5 9 9 9 12 12 foe e d entr e 200 250 250 80 200 200 150 150 Tension de sortie 230 1 Vac Plage de tension 185 245 de sortie Vac Fr quence Hz 50 ou 60 0 01 quartz Forme d onde Sinusoide pure Distorsion TDH Max 5 Facteur de puissance Indifferent Economy DS6 on Puissance lt 25W 145VAC cr te 300V convient pour lampes SL PL et n on uminosit normale et horloges Charge non lin aire facteur cr te 3 1 VA 25 C
23. MultiPlus Compact aus Stellen Sie den Phoenix Multi Compact MultiPlus Compact zur ck indem Sie ihn ausschalten 4 Sek warten und dann wieder einschalten L dt er nun wieder normal muss der Temperaturf hler ausgetauscht werden victron energy N y 25 6 TECHNISCHE DATEN 6 1 Allgemeines K hlung Interne dynamische K hlung Temperaturbereich Betriebstemperatur 20 50 C Lagertemperatur 25 60 C Schutzeinrichtungen Ausgang kurzschlussfest Uberlast Zu hohe Batteriespannung Zu niedrige Batteriespannung 230V Ausgangsspannung des Inverters Brummspannung ber der Eingangsgleichspannung Temperatur gesch tzt Transformator Elektronik amp Leistungsteil Batterie wenn der Sensor angeschlossen ist Relative Feuchtigkeit 0 95 EMV Elektromagnetische Vertr glichkeit nach EMV Richtlinie 89 336 EEC Emission EN 55014 1993 en EN50081 1 EN61000 3 2 EN61000 3 3 Immission EN 55104 1995 Sicherheit Niederspannungsrichtlinie 73 23 EEG und 93 68 EEG EN60335 1 und EN60335 2 29 KFZ Richtlinie 95 54 EC 26 victron energy N y 6 2 Inverter 12 800 12 1200 12 1600 24 800 24 1200 24 1600 48 1200 48 1600 135 150 170 116 125 135 112 120 12 800 12 1200 12 1600 24 800 24 1200 24 1600 48 1200 48 1600 Eingangsspannungs
24. accukabel aan de zwart aan rechterzijde zie Anhang A Draai de moeren stevig aan om overgangsweerstanden zo laag mogelijk te maken victron energy 11 O y 3 5 Aansluiten AC kabels 12 Dit is een product uit veiligheidsklasse dat wordt geleverd met een aardklem ter beveiliging De in en of uitgangsklemmen en of het aard punt aan de buitenkant van het product moeten zijn voorzien van een ononderbreekbare aarding ter beveiliging Zie hiervoor de volgende instructies a De Phoenix Inverter Compact heeft een vrij zwevende uitgangspanning De behuizing moet geaard worden met het aard punt aan de buitenkant van het product De N uitgang moet geaard worden om verzekerd te zijn van de goede werking van een aardlek schakelaar b De Phoenix Multi MultiPlus Compact is voorzien van een aard relais zie Aappedix 2 dat de N uitgang automatisch met de behuizing verbint wanneer geen externe wisselspanning voeding beschikbaar is Wanneer een externe wisselspanning voeding wordt aangeboden zal het aard relais openen voordat het ingang veiligheids relais sluit zie appendix 2 Dit is om goede werking van een op de uitgang aangesloten aardlekschakelaar te verzekeren In een vaste installatie kan een ononderbreekbare aarding vezekerd worden met de aard draad van de wisselspanning ingang Zoniet dan dan moet de behuizing geaard worden In een mobiele installatie bijvoorbeeld met walstroom stekker zal onderbreking van de walaans
25. as follows to connect the AC cables The AC output cable can be connected directly to the G ST18i male connector the connector pulls out The terminal points are indicated clearly From left to right N neutral earth and L1 phase The AC input cable can be connected directly to the G ST18l female connector the connector pulls out The terminal points are indicated clearly From left to right L1 phase earth and N neutral Push the G ST18i input connector into terminal connector near to rear side Push the G ST18i output connector into terminal connector near to front side 3 6 Optional Connections A number of optional connections are possible Undo the four screws at the front of the enclosure and remove the front panel 3 6 1 Second Battery The Phoenix Multi Compact MultiPlus Compact has a connection for charging a starter battery For connection see appendix 1 12 victron energy Gul y 3 6 2 Temperature Sensor Multi Compact MultiPlus Compact The temperature sensor supplied with the product may be used for temperature compensated charging The sensor is insulated and must be mounted on the batteries minus pole Default output voltages for Float and Absorption are at 25 C In adjust mode temperature compensation is disabled 15 0 30 14 5 29 14 0 28 13 5 27 13 0 26 Volts 12 5 25 Volts 12 0 24 11 5 23 11 0 22 10 5 21 10 0 t 20
26. baja 230 V de salida del inversor Ondulaci n de la tensi n CC de entrada demasiado alta Temperatura demasiado alta transformador Electr nica y etapa de potencia Bater a si est conectado el sensor Humedad relativa 0 95 EMC Compatibilidad electromagn tica seg n la directiva EMC EMC 89 336 EEC Emisi n EN 55014 1993 en EN50081 1 EN61000 3 2 EN61000 3 3 Inmunidad EN 55104 1995 Seguridad Normativa de baja tensi n 73 23 EEG en 93 68 EEG EN60335 1 en EN60335 2 29 Automoci n 95 54 EC 24 victron energy O y 6 2 Inversor 12 800 135 12 1200 50 12 1600 70 24 800 16 24 1200 125 24 1600 40 48 1 12 200 48 1600 20 12 800 12 1200 12 1600 24 800 24 1200 24 1600 48 1 200 48 1600 Rango de tensi n de entrada Vdc 9 5 16 1 19 0 32 2 38 0 64 4 Tensi n de arranque Vdc 10 9 21 8 43 6 Tensi n de desconexi n baja Vdc 9 0 56 Tensi n de desconexi n alta Vdc 64 4 Ondulaci n de tensi n Vrms 1 25Vrms Tensi n nominal de entrada A 65 100 130 35 50 65 25 35 Tensi n m xima de entrada A 85 130 170 40 65 85 30 40 Consumo en vacio W 8 8 12 12 Modo ahorro 5 5 12 12 Fusible de entrada 200 250 250 200
27. be set at from 2 to 30A The remote control panel setting overrides the internal setting PowerAssist Boosting the capacity of shore or generator power MultiPlus only default on The feature that distinguishes the Phoenix MultiPlus Compact from the standard Multi Compact is PowerAssist This feature takes the principle of PowerControl to a further dimension allowing the MultiPlus Compact to supplement the capacity of the alternative source Where peak power is so often required only for a limited period it is possible to reduce the size of generator needed or conversely enable more to be achieved from the typically limited shore connection When the load reduces the spare power is used to recharge the battery Note 1 Minimum shore current 2 A or generator capacity equal to the Multi rating required for proper operation of PowerAssist Note 2 Some modern AC generators use a static inverter to generate the AC output Some of these generators also reduce rpm when operating with reduced load By enabling the Dynamic Current Limit function VEConfigure the MultiPlus Compact can be used to assist the generator when suddenly a high load is connected External Alarm Relay and Virtual Switch default disabled An open collector output is available to connect a relay that can be used for remote alarm and other purposes a o generator start signal The maximum voltage current that can be switched open collector transistor 66V 40mA The
28. bevat de volgende zaken Phoenix Multi Compact Gebruikershandleiding amp lnstallatiehandleiding Zakje met aansluitmateriaal met daarin Temperatuursensor Vijf bevestigingsschroeven Bevestigingsplaat Waarschuwingssticker laadstroom 3 2 Locatie De Phoenix Multi Compact dient in een droge goed geventileerde ruimte te worden geinstalleerd zo dicht mogelijk bij de accu s Rondom het apparaat dient een ruimte van tenminste 50mm te worden vrijgehouden voor koeling Een te hoge omgevingstemperatuur heeft de volgende consequenties Kortere levensduur Lagere laadstroom Lager piek vermogen of geheel afschakelen van de omvormer Plaats het apparaat nooit direct boven de accu s De Phoenix Multi Compact is geschikt voor wandmontage Voor de montage zijn aan de achterzijde van de behuizing gaten en een beugelbevestiging aangebracht zie Anhang A Het apparaat kan zowel horizontaal als verticaal gemonteerd worden maar verticaal monteren is de beste montage In deze positie is de koeling namelijk optimaal d De binnenzijde van het apparaat dient ook na installatie goed bereikbaar te blijven Zorg ervoor dat de aansluitkabels zijn voorzien van zekeringen en stroomonderbrekers Houd de afstand tussen de Phoenix Multi Compact en de accu zo kort mogelijk om het spanningsverlies over de kabels tot een minimum te beperken In alle apparatuur waarin sprake is van het omvormen van een groot elektrisch vermogen moet uit voorzorg dit produ
29. caso deber desactivarse la comprobaci n de curva de corriente alterna 1 2 Cargador de bater as s lo Multi Compact MultiPlus Compact Sistema de carga variable de 4 etapas inicial absorci n carga lenta almacenamiento El Phoenix Multi Compact MultiPlus Compact dispone de un sistema de gesti n de bater as variable controlado por microprocesador que puede configurarse para los distintos tipos de bater a Su funci n variable optimizar autom ticamente el proceso en base al uso que se le d a la bater a victron energy 3 O y La cantidad de carga adecuada tiempo de absorci n variable Cuando la descarga es poca por ejemplo un yate conectado a la red del pantal n la fase de carga de absorci n se acorta para as evitar una sobrecarga de la bater a En los casos de una descarga profunda el tiempo de carga de absorci n aumenta autom ticamente para garantizar que la bater a se recargue completamente Prevenci n de da os debido a un exceso de burbujeo el modo BatterySafe Si para cargar una bater a r pidamente se ha elegido una combinaci n de alta corriente de carga con una tensi n de absorci n elevada Multi Compact MultiPlus Compact evitar que se produzcan da os por exceso de burbujeo limitando autom ticamente el ritmo de incremento de tensi n una vez se haya alcanzado la tensi n de burbujeo Menor envejecimiento y necesidad de mantenimiento cuando la bater a no est
30. charge current setting is 75 of the maximum charge current This current will be too high for most applications For most battery Types the optimal charge current is 0 1 0 2x the battery capacity 14 victron energy Gul y Using the dipswitches Set up E DS 1 DS 1 Hoff DS2 f DS 2 Be on Ds 3 MH DS 3 TR DS 4 N DS 4 eh DS 5 DS 5 Ds 6 DS 6 DS 7 MW DS 7 DS 8 M DS 8 DS1 off See note DS 1 not used and must be switched to Off Note about DS 2 DS 2 should be switched on default setting when no remote panel or remote on off switch is used activate the setting switches DS 3 to DS 8 DS 2 should also be switched off to use a remote control panel or remote on off switch DS 8 DS 8 Battery charge Type DS 1 ff DS 1 DS 2 M on DS 2 DS 3 DS 3 DS 4 DS 4 Gest DS 5 DS 6 MH DS 6 DS 7 0 DS 7 DS3 off DS4 off Type 1 gel Store the settings DS3 DS4 by changing the DS8 DS3 on DS4 off Type 2 switch position off to on and then back to off DS3 off DS4 on Type 3 DS3 on DS4 on Type 4 victron energy Gul y Inverter frequency DS 7 DS 8 DS 1 DS 2 f on DS 3 A DS 4 DS 5 DS 6 o DS 1 DS 2 DS 3 DS 4 DS 5 DS 6 DS 7 DS 8 DS5 off 50Hz Store the settings DS5 by changing the DS8 switch DS5 on 60Hz position off to on and then back to off Economy DS 1 Hoff DS 1 DS 2 on Ds 3 p
31. cualquier da o ocasionado al equipo durante el transporte si este no lleva su embalaje original Guarde el producto en un entorno seco la temperatura de almacenamiento debe oscilar entre 20 C y 60 C Consulte el manual del fabricante de la bater a para obtener informaci n sobre el transporte almacenamiento recarga y eliminaci n de la bater a 2 victron energy O y 1 DESCRIPCI N 1 1 General Multifunciones s lo Multi Compact MultiPlus Compact El Multi Compact debe su nombre a las m ltiples funciones que puede realizar Re ne en una sola carcasa compacta un poderoso inversor sinusoidal un sofisticado cargador de bater as con tecnolog a de carga variable y un conmutador de transferencia de CA de alta velocidad Adem s de estas funciones b sicas el Multi Compact dispone de varias funciones avanzadas que proporcionan una gama de nuevas aplicaciones tal y como se explica a continuaci n Alimentaci n CA ininterrumpida s lo Multi Compact MultiPlus Compact En caso de apag n o de desconexi n del pantal n o del generador el inversor del Multi Compact se activa autom ticamente y asume el suministro para alimentar las cargas conectadas Esto ocurre tan r pido menos de 20 milisegundos que los ordenadores y dem s equipos electr nicos contin an funcionando sin interrupci n PowerControl Potencia limitada del generador o del pantal n s lo Multi Compact MultiPlus Compact El Multi Compact es u
32. de charge fixe ce r glage d termine la dur e de la phase de charge en mode Absorption En courbe de charge adaptative ce r glage d termine la dur e maximale de la phase de charge en mode Absorption ind pendamment des calculs automatiques du chargeur La dur e maximum d absorption peut tre r gl e de 1 a 12 heures victron energy 21 Gul y Tension de charge Absorption et Float Si les valeurs r gl es en usine ne conviennent pas l application il est possible de les modifier Intervalle et dur e d Absorption r p t e usine 1 heure tous les 7 jours Si les valeurs r gl es en usine ne conviennent pas l application il est possible de les modifier 4 5 R glages sp ciaux Les r glages suivants sont modifiables uniquement avec VEConfigure Bulk Protection protection volum trique usine on Si apr s 10 heures de charge en mode Bulk le chargeur n a pas atteint la tension d absorption il se peut que la batterie soit d fectueuse Par s curit le chargeur s arr te automatiquement au bout de 10 heures de charge en mode Bulk Le voyant rouge alarme sur l appareil s allume ou le voyant Bulk sur le tableau de commande Phoenix Multi Control AC Waveform Check v rification de la forme d onde usine on L appareil v rifie non seulement la valeur de sa tension d alimentation mais aussi la qualit de l onde sinuso dale Si appareil fonctionne mal quand il est aliment par un groupe
33. de la batterie a tension constante La dur e est variable et sera de 20x la dur e Bulk sauf si une dur e inf rieure a t r gl e Mode Float La tension r duite Float sert maintenir la batterie charg e et a compenser son autod charge Mode Veille Apr s 1 journ e en mode Float la tension du chargeur ramen e a 13 2V 26 4V 52 8V Ceci permet de limiter les pertes d eau lorsque le chargeur est en marche pour une longue p riode Le chargeur repasse ensuite en mode Absorption a intervalles r guliers r glables valeur par d faut 7 jours et pendant une dur e galement r glable valeur par d faut 4 quarts d heure 20 AD y victron energy 4 4 R glages du chargeur Multi MultiPlus Compact uniquement Les r glages suivants sont modifiables uniquement avec VEConfigure Arr t du chargeur usine marche Pour une utilisation de l appareil en uniquement en convertisseur il est possible de d sactiver le chargeur Le commutateur de transfert rapide reste op rationnel 4 4 1 Les trois courbes de charge pr programm es Pour plus de pr cisions sur la charge de batteries voir notre livre Electrivity on Board disponible en t l chargement libre sur www victronenergy com Consulter le fournisseur des batteries ou la documentation fournie pour conna tre les valeurs pr conis es Le Phoenix Multi MultiPlus Compact propose en standard trois courbes de charge voir aussi les explications et graphiques au 4 3 page
34. een deel van de belasting of belasting plaats accu s met een hogere capaciteit Monteer kortere en of dikkere accukabels Controleer de dynamo De LED alarm Voor alarm alt 3 Controleer de accukabels en knippert rimpelspanning op de DC accuaansluitingen Wees er aansluiting overschrijdt zeker van dat de 1 25Vrms accucapaciteit voldoende is verhoog deze eventueel De LED lalarm De omvormer is uitgeschakeld Zie de bovenstaande branat als gevolg van voortduring van oplossingen een van bovenstaande voor alarm omstandigheden 22 victron energy N y Probleem Oorzaak Oplossing De lader werkt niet De netspanning of frequentie is buiten het bereik Zorg dat de netspanning tussen 185 VAC en 265 VAC komt te liggen en dat de frequentie overeenkomt met de instelling De thermische onderbreker is geactiveerd Reset de 30 A thermische onderbreker De accu wordt niet volledig opgeladen Verkeerde laadstroom Stel de laadstroom in tussen 0 1 en 0 2x de accucapaciteit Een slechte accuaansluiting Controleer de accuaansluitingen De absorptionspanning is op een verkeerde waarde ingesteld Regel de absorptionspanning af op een goede waarde De floatspanning is op een verkeerde waarde ingesteld Regel de floatspanning af op een goede waarde De capaciteit van de accu is te groot Sluit een accu aan met een kleinere capaciteit en verhoog de laadst
35. el producto de la humedad y de los gases de combusti n y mant ngalo limpio victron ener A y W 21 5 TABLA DE RESOLUCI N DE PROBLEMAS Proceda de la manera siguiente para detector r pidamente los fallos m s comunes Las cargas CC deber n desconectarse de las bater as y las cargas CA deber n desconectarse del inversor antes de comprobar el inversor y o el cargador de bater as Consulte a su distribuidor de Victron Energy si no puede resolver el fallo Problema Causa Soluci n El inversor no La tensi n de la bater a es muy Compruebe que la tensi n de funciona al alta o muy baja la bater a sea la correcta ponerlo en marcha El inversor no El procesador est en modo Desconecte la tension de red funciona parada Ponga el conmutador frontal en off espere 4 segundos y vuelva a poner el conmutador en on El LED de alarma Prealarma 1 La tensi n CC de Cargue la bater a o compruebe parpadea entrada es baja las conexiones de la misma El LED de alarma Prealarma 2 La temperatura Coloque el inversor en una parpadea ambiente es demasiado alta habitaci n fresca y bien ventilada o reduzca la carga El LED de alarma parpadea Prealarma 3 La carga del inversor supera la carga nominal Reducir la carga El LED de alarma parpadea Prealarma 4 La tensi n de ondulaci n en la entrada CC supera 1 25 Vrms Compruebe los cables de la bater a y los terminal
36. face 3 6 Raccordement d options En plus des raccordements standard plusieurs raccordements optionnels sont possibles 3 6 1 Batterie auxiliaire de d marrage Le Phoenix Multi Compact est quip d une sortie auxiliaire pour la charge d une batterie de d marrage Pour le raccordement voir appendice 1 14 AM y victron energy 3 6 2 Sonde de temp rature Multi MultiPlus Compact La sonde de temp rature livr e avec l appareil permet de corriger la tension de charge voir appendice A La sonde est isol e et doit tre mont e sur le p le n gatif de la batterie Les tensions de charge Absorption et Float sont r gl es en usine pour 25 C La correction de temp rature n est pas op rationnelle en mode param trage 15 0 30 14 5 29 14 0 28 13 5 27 13 0 26 Volts 12 5 25 Volts 12 0 24 11 5 23 11 0 22 10 5 21 10 0 20 0 5 10 15 20 25 30 35 40 45 50 55 60 Battery temperature 3 6 3 Commande a distance L appareil peut tre command distance de deux fa ons Par un interrupteur externe Par un tableau de commande distance Pour le raccordement d un interrupteur voir appendice A Si un interrupteur externe est seul utilis tenir compte des indications suivantes N est op rationnel que si le commutateur de l appareil est sur on Ne doit PAS tre raccord si un tableau de commande distance est install
37. hebben geladen de absorption spanning nog niet heeft bereikt kan het zijn dat de accu defect is Om verdere schade te voorkomen zal de lader na 10 uur bulk automatisch worden uitgeschakeld De rode LED alarm gaat dan branden AC Waveform Check standaard aan De Phoenix Multi Compact controleert of the netspanning niet alleen de juiste voltage heeft maar ook de juiste sinus vorm Indien de Phoenix Multi Compact niet goed functioneert op een generator kan deze functie worden uitgeschakeld PowerContol omgaan met beperkte generator walstroom Ter bescherming van de generator of van de walstroomaansluiting wordt de laadstroom zodanig ingesteld dat de gezamenlijk afgenomen stroom door de lader en de AC verbruikers niet boven de ingestelde stroom komt Als het AC verbruik boven de ingestelde stroom komt zal de lader uitschakelen en de mains on LED gaan knipperen Het is nu mogelijk dat de walzekering doorslaat of de generator door overbelasting uitschakelt In dat geval zal de Multi Compact proberen om te schakelen naar omvormerbedrijf De generator walstroom kan worden ingesteld van 2 tot 30A De stapgrootte is 1A Bij gebruik van het Remote Control paneel wordt de walstroom instelling bepaald door dit paneel Wanneer de aan de Phoenix Multi Compact aangeboden spanningsvorm niet zuiver sinusvorming is bestaat de kans dat de Phoenix Multi Compact deze niet zal accepteren U kunt deze detectie uitschakelen door de shore current l
38. kan geprogrammeerd worden met VEConfigure 4 6 Onderhoud De Phoenix Multi Compact vereist geen specifiek onderhoud Het volstaat alle verbindingen eenmaal per jaar te controleren Voorkom dat de Phoenix Multi Compact vochtig wordt en houd het apparaat schoon victron ener 21 y J Ss 5 FOUTZOEKSCHEMA Met behulp van onderstaande stappen kunnen de meest voorkomende storingen snel worden opgespoord Voordat testen met de omvormer en of acculader worden uitgevoerd dienen de DC belastingen te worden losgekoppeld van de accu s en de AC apparatuur dient te worden losgekoppeld van de omvormer Indien de fout niet opgelost kan worden raadpleeg uw Victron Energy distributeur Probleem Oorzaak Oplossing De omvormer De accuspanning is te hoog of Zorg dat de accuspanning werkt niet te laag binnen de juiste waarde is wanneer deze wordt ingeschakeld De omvormer Processor staat in uit mode Ontkoppel de netspanning werkt niet Schakel de omvormer uit Wacht 4 seconden Schakel de omvormer weer aan De LED alarm Voor alarm alt 1 de Laad de accu op of controleer knippert accuspanning is laag de accu aansluitingen De LED alarm Voor alarm alt 2 de belasting Ontkoppel een deel van de knippert op de omvormer is hoger dan belasting de nominale belasting De LED alarm Voor alarm alt 3 lage Laad de accu s op ontkoppel knippert accuspanning en te hoge
39. la batterie et la remplacer Capacit batterie insuffisante R duire le courant de charge Augmenter la capacit totale des batteries La batterie est expos e a la chaleur Raccorder la sonde de temp rature Le courant de charge tombe a 0 quand le mode Absorption est atteint La batterie est surchauff e gt 50 C Choisir un endroit plus frais pour la batterie r duire le courant de charge v rifier s il n y a pas d l ments en court circuit La sonde de temp rature est d fectueuse D connecter la sonde a l int rieur d l appareil r initialiser l appareil en l arr tant pendant plus de 4 secondes si le chargeur fonctionne a la remise en marche la sonde doit tre remplac e victron energy 25 Gul y 6 SPECIFICATIONS TECHNIQUES 6 1 G n ralit s Ventilation Convection forc e interne asservie a la temp rature Temp ratures admises En fonctionnement 20 50 C En stockage 25 60 C Protections Court circuit en sortie Surcharge Tension batterie trop haute Tension batterie trop basse 230V sur la sortie du convertisseur Ondulation trop forte sur alimentation DC Temp rature Transformateur Electronique amp Puissance Batterie si sonde install e Humidit relative 0 95 sans ruissellement EMC Compatibilit lectromagn tique selon la directive EMC EMC 89 336 EEC
40. lich von qualifizierten Fachkr ften ausgef hrt werden Benutzen Sie das Ger t niemals in R umen wo die Gefahr einer Gas oder Staubexplosion besteht Lesen Sie die Angaben des Batterieherstellers und vergewissern Sie sich dass die Batterie f r das Ger t geeignet ist Die Sicherheitsvorschriften des Batterieherstellers sind immer einzuhalten VORSICHT Heben Sie schwere Lasten nie ohne Hilfe Installation Lesen Sie erst die Installationshinweise in der Bedienungsanleitung bevor Sie das Ger t anschlie en Dies ist ein Ger t der Sicherheitsklasse Geh use geerdet Die Schutzerde an den Wechselspannungs Ein und Ausgangsklemmen darf aus Sicherheitsgr nden nicht unterbrochen werden Alternativ kann der au enliegende Erdungspunkt am Geh use benutzt werden Wenn die Vermutung besteht dass die Schutzerdung unterbrochen ist muss das Ger t au er Betrieb gesetzt werden und gegen jedes unbeabsichtigte Betreiben gesichert werden ziehen Sie einen Fachmann zu Rate Sorgen Sie daf r dass die Anschlusskabel abgesichert und mit Leistungsschaltern ausgestattet sind Wechseln Sie nie ein Sicherungselement gegen eines mit unterschiedlichem Wert aus Lesen Sie in der Gebrauchsanweisung nach welche Typenkennwerte geeignet sind Vergewissern Sie sich vor dem Einschalten des Ger ts dass die Anschlusswerte des Netzes mit den in der Bedienungsanleitung angegebenen Werten bereinstimmen Sorgen Sie daf r dass das Ger t nur innerhalb de
41. pr c dente Courbe fixe 3 tapes de charge La dur e de la phase de charge d Absorption est fixe et r glable Apr s la phase d Absorption le chargeur passe en mode Float pour une dur e galement r glable et revient ensuite p riodiquement en mode Absorption pour des dur es g n ralement courtes Courbe Adaptative a 4 tapes de charge La dur e de la phase de charge d Absorption est d termin e par le chargeur en fonction du d roulement de la phase de charge Bulk Vient ensuite le mode Float pendant 24 heures suivie d un mode Veille o la tension est r duite 13 26 52 V Comme pour la courbe fixe le chargeur revient ensuite en mode Absorption a intervalles r guliers intervalles et dur e r glables Courbe Adaptative avec mode BatterySafe r glage usine Si une tension et une intensit lev es ont t choisies pour obtenir une charge rapide le Multi Compact MultiPlus r duit la vitesse de mont e en tension lorsque la tension de gazage est atteinte Ceci afin d viter un gazage excessif et pour prot ger la batterie 4 4 2 Autres r glages Courant de charge usine 75 Le courant de charge est r gl en usine a 75 du maximum Cette intensit sera dans certains cas trop lev e En r gle g n rale l intensit de charge d une batterie doit tre situ e entre 0 1 et 0 2 fois la capacit totale de la batterie Dur e d absorption dur e d absorption maximum usine 4 heures En courbe
42. siehe Anhang A Wenn Sie eine Phoenix Multi Control einsetzen gilt das Gleiche wie zuvor beim Fernbedienungsschalter der Frontschalter des Phoenix Multi Compact Multiplus Compact muss auf on stehen 3 6 4 Externes Alarm Relais und Schaltausgang Um z B ein Alarm Relais z B Generator Startsignal zu schalten steht ein Transistorausgang zur Verf gung Der maximale Schaltstrom betr gt 40mA bei maximal 66 V Der Transistorschaltausgang kann mithilfe von VEConfigure programmiert werden victron energy N y 15 4 EINSTELLUNGEN Die Einstellungen d rfen nur von einer qualifizierten Elektrofachkraft ge ndert werden Lesen Sie vor eventuellen Anderungen erst die Anweisungen Die Batterien m ssen w hrend des Ladevorgangs in einem trockenen gut ventilierten Raum stehen 4 1 Standardeinstellungen Inverterspannung 230 V Wechselspannung Lader an aus an Ladecharakteristik adaptive Ladekennlinie f r Gel Batterien Ladestrom 75 vom maximalen Ladestrom Gasungs absorption Spannung 14 4 V 28 8V 57 6 V Konstantspannungsphase 4 Stunden Ladeerhaltungsspannung 13 8 27 6 55 2 V Dauer der wiederkehrenden Konstantspannungsphase 1 Stunde Intervall der wiederkehrenden Konstantspannungsphase 7 Tage Konstantstromzeit berwachung 10 Stunden Eingangssinus berpr fung an Netzunterst tzung nur mit Multi Plus Compact an Generator Land Strom 12A Systemfrequenz Multi Compact MultiPlus Compact Automatisch Inv
43. tableau ci dessous permet d identifier rapidement certains d fauts Avant de tester le l appareil les utilisations en DC doivent tre d connect es de la batterie et les appareils AC doivent tre d connect s du convertisseur Si le d faut n est pas r solu consultez votre distributeur Victron Energy Probleme Cause possible Solution possible Le convertisseur ne fonctionne pas alamise en marche La tension de batterie est trop haute ou trop basse Assurer une tension batterie correcte Le convertisseur ne fonctionne pas Processeur en mode arr t D connecter l alimentation AC arr ter le convertisseur attendre 4 secondes d marrer le convertisseur La LED Alarm Pr alarme 1 possibilit Charger la batterie et ou clignote Tension batterie trop basse v rifier les raccordements La LED Alarm Pr alarme 2 possibilit D connecter tout ou partie clignote Surcharge en sortie du des consommateurs en convertisseur sortie La LED Alarm Pr alarme 3 possibilit Charger la batterie et ou clignote Tension batterie trop basse et v rifier les raccordements surcharge en sortie du d connecter tout ou partie convertisseur des consommateurs en sortie v rifier le s alternateur s La LED Alarm Pr alarme 4 possibilit V rifier les raccordements clignote Ondulation r siduelle sur la batterie section et l alimentation DC sup r
44. und N sse 22 AD y victron energy 5 ST RUNGSSUCHE Anhand der unten stehenden Tabelle k nnen die meisten St rungen schnell gefunden werden Bevor Sie den Inverter und oder das Batterieladeger t testen m ssen die Verbraucher an den Batterien und die Wechselstrom Ger te am Inverter ausgeschaltet werden Wenden Sie sich an Ihren Victron Energy H ndler wenn der Fehler nicht behoben werden kann Problem Ursache L sung Nach dem Einschalten l uft der Inverter nicht an Die Batteriespannung ist zu hoch oder zu niedrig Sorgen Sie daf r dass die Batteriespannung innerhalb der korrekten Werte liegt Der Inverter l uft nicht Der Prozessor ist im Au er Betrieb Modus Schalten Sie die Netz spannung ab Schalten Sie das Ger t aus und warten Sie 4 Sekunden Schalten Sie es dann wieder ein Die Alarm LED Anzeige blinkt Voralarm 1 Die Batterie spannung ist zu niedrig Laden Sie die Batterie auf und kontrollieren Sie die Batterieanschl sse Die Alam LED Anzeige blinkt Voralarm 2 Die Umgebungstemperatur ist zu hoch Bringen Sie den Inverter in einen k hlen und gut bel fteten Raum oder verringern Sie die Anzahl der angeschlossenen Verbraucher Die Alam LED Anzeige blinkt Voralarm 3 Die angeschlossenen Verbraucher bersteigen die Nennleistung des Inverters Verringern Sie die Anzahl der angeschlossenen Verbraucher Die Alam LED Anzeig
45. werking worden gesteld Dit kan door middel van een instelling VE configure of door gebruik te maken van het Phoenix Multi Control paneel AC ingangsstroom op 0 zetten Voor de Phoenix Inverter Compact dient u het Phoenix Inverter Control paneel te gebruiken 2 3 Speciale laad mode Equalizing Het dient de aanbeveling dat bepaalde Typ batterijen eens in de maand extra nageladen te worden In de Equalizing modus gaat de Phoenix Multi Compact gedurende een uur met een verhoogde spanning laden 1V boven de Absorptionspanning voor een 12V accu 2V voor een 24V accu De laadstroom is dan begrensd op 1 4 van de ingestelde waarde Indien er een Multi Control aangesloten heeft zal het bulk en absorption LED afwisselend gaan knipperen De Equalizing modus geeft een hogere laadspanning dan de meeste gelijkstroomverbruikers aankunnen Deze moeten worden losgekoppeld voordat er extra wordt nageladen victron energy N y zZ rm Forced absorption In sommige omstandigheden kan het wenselijk ziin om de accu voor een vaste tijd met een Absorption spanning te laden In de Forced Absorption modus gaat de Phoenix Multi Compact gedurende de ingestelde maximale absorption tijd met de normale Absorption spanning laden De gele led Charger brandt De Phoenix Multi Compact is zowel vanaf het remote control als met de frontschakelaar in deze toestanden te brengen Voorwaarde is wel dat alle schakelaars front remote control op de stand
46. y despu s otra vez a off Conmutador de ahorro DS 1 DS 2 DS 3 DS 4 DS 5 DS 6 DS 7 DS 8 DS 1 bot DS 2 on DS 3 Be DS 4 DW DS 5 DS 6 Bx x DS 7 DS 8 Een DS6 off DS6 on normal ahorro Guarde los ajustes DS6 cambiando la posici n off del conmutador DS8 a on y despu s otra vez a off L mite de la corriente CA de entrada DS 1 DS 2 DS 3 DS 4 DS 5 DS 6 DS 7 DS 8 ES DS 1 Hoff DS 2 on DS 3 Git DS 4 DS 5 DS 6 DS 7 Mx x DS 8 DS7 off DS7 on L mite CA 16 Amp L mite CA 6 Amp Guarde los ajustes DS7 cambiando la posici n off del conmutador DS8 a on y despu s otra vez a off victron ener A y W 17 4 3 La curva de carga variable Charge current 120 100 80 Amps 60 40 20 0 Time Volts H Charge voltage 64 32 60 30 56 28 Bulk hours Absorption 1 day 7 days reduced 7 days float Carga de 4 etapas 1 hour Repeated Absorption 18 Modo bulk Introducido al arrancar el cargador Se aplica una corriente constante hasta alcanzar la tensi n de burbujeo 14 4 V resp 28 8 V compensaci n de temperatura Modo BatterySafe Si para cargar una bateria r pidamente se ha elegido una combinaci n de alta corriente de carga con una tensi
47. 1600 48 1200 48 1600 135 150 170 116 125 40 112 120 12 800 12 1200 12 1600 24 800 24 1200 24 1600 48 1200 48 1600 Armario aluminio protecci n de clase IP21 color Azul RAL 5012 Dimensiones 375 mm x 215 mm x 115mm ver ap ndice A Al x An x P peso kg 9 10 10 9 10 10 10 10 Cable de 1 5m 15m 15m 15m 15m 15m 15m 1 5 m conexi n de la bater a Conexi n de Entrada Salida 2 conectores G ST18i 2 5 mm CA Conexi n de la Terminales en el circuito impreso bater a de conector adecuado para cables de 1 mm arranque Conexi n Conmutador remoto conector para 3 hilos de Y mm externa sensor Sensor de temperature de la bater a conector para 2 hilos de 1mm conmutador remoto Alarma transistor colector abierto 66 40 mA conector para 2 hilos de Y 0 5 mm Interfaz serie Para control remoto de Phoenix conector UTP Para Mk 1 con software VEConfigure victron energy N y ons Overview connections A B Dipswitch AC input Circuit breaker C Comm port UTP VEConfiaure D Temperature sensor 1 Red sensor sk 2 black sensor EEE E Alarm contact open collector driver 1 collector G Auxiliary battery Fast on terminal 2 gnd Max power 150mA 66V Remote switch 1 charger only 2 middle terminal gnd Relay coil KA Auxiliary sk Battery _o Did M victron energy Y xi
48. 2 800 12 1200 12 1600 48 1600 24 1600 48 1200 Capacidad de bateria 40 200 40 400 100 400 150 700 200 700 recomendada Ah Observaci n La resistencia interna es el factor determinante al trabajar con baterias de poca capacidad Consulte a su proveedor o las secciones relevantes de nuestro libro Electricidad a Bordo que puede descargarse de nuestro sitio web Procedimiento Conecte los cables de bater a de la manera siguiente A Utilice una llave de tubo aislada para no cortocircuitar la bater a No ponga los cables de la bater a en contacto entren ellos Conecte los cables de bater a el rojo a la izquierda y el negro a la derecha de la bater a ver Ap ndice A Si se conectan los cables al rev s a y a se podr an causar da os al Phoenix Multi Compact El fusible de seguridad interno del Multi Compact podr a da arse Apriete bien las tuercas para reducir la resistencia de contacto todo lo posible victron energy A y 11 3 5 Conexi n del cableado CA Este producto es un dispositivo de clase de seguridad suministrado con terminal de puesta a tierra Los terminales de entrada y o salida CA y o el punto de puesta a tierra de la carcasa ubicado en el exterior del producto deber n conectarse a tierra de manera permanente Consulte las instrucciones siguientes a El Phoenix Inverter Compact dispone de una salida CA de libre flotaci n El punto
49. 6 EEC Emission EN 55014 1993 en EN50081 1 EN61000 3 2 EN61000 3 3 Immunity EN 55104 1995 Safety Low voltage norm 73 23 EEG en 93 68 EEG EN60335 1 en EN60335 2 29 Automotive 95 54 EC 22 victron energy Gul y 6 2 Inverter 12 800 12 1200 12 1600 24 800 24 1200 24 1600 48 1200 48 1600 135 150 170 116 125 140 112 120 12 800 12 1200 12 1600 24 800 24 1200 24 1600 48 1200 48 1600 Input voltage range 38 0 64 4 Vdc 9 5 16 1 19 0 32 2 Start voltage Vdc 10 9 21 8 43 6 Input low switch off 56 voltage Vdc 9 0 18 0 Input high switch off 64 4 voltage Vdc 161 32 2 Voltage ripple Vrms 1 25Vrms Input current nominal 65 100 130 35 50 65 25 35 A Input current 85 130 170 40 65 85 30 40 maximum A Zero load power W 8 8 8 12 12 12 15 15 Economy 5 5 5 9 9 9 12 12 Input safety fuse 200 250 250 80 200 200 150 150 Output Vac 230 1 Output Voltage 185 245 Range Vac Frequency Hz 50 60 0 01 crystal Output Voltage Pure sinewave THD Max 5 Power factor All loads Economy DS6 on 145VAC top 300V load lt 25W special adapted for SL PL and tube lamps nominal brightness and clocks Non linear load crest 800 1200 1600 800 1200 1600 1200 1600 factor 3 1 VA 25 C Nominal power W 650 1000 1300 650 1000 1300 1000 1300 cos p 1 0 25 C Nominal power W 600
50. 800 1200 1600 800 1200 1600 1200 1600 Puissance nominale W cos 1 0 25 C 650 1000 1300 650 1000 1300 1000 1300 Puissance nominale W cos 1 0 40 C 600 900 1100 600 900 1100 900 1100 Puissance instantan e W 1900 2000 2300 1900 2600 3000 2600 3000 Comportement a la Mise en marche Tension nominale atteinte en moins de 20mS Rendement a Gen 87 86 84 88 87 86 87 86 a g 90 88 87 90 89 87 90 88 2 Pnom Courant de court E 10 12 13 10 12 13 13 15 victron energy 27 Gul y 6 3 Chargeur r glages usine 12 800 12 1200 12 1600 24 800 24 1200 24 1600 48 1200 48 1600 135 150 170 116 125 135 112 20 Tension d entr e 200 250 Vac Limites de tension lt 180 en gt 270 Vac Fr quence Hz 45 55 ou 55 65 Courant d alimentation Tension d alimentation 230 Vac Pas de consommation AC en sortie maxi A 2 7A 3 9A 5 6A 2 5A 3 8A 6 3A Fusible d entr e Thermique 250 Vac 16A 16A 16A 16A 16A 16A 16A 16A Rendement 84 82 81 85 84 83 85 84 Cos q facteur de 10 puissance 2 Tension de charge Absorption par defaut 14 40 28 80 57 6 Vdc Tension de charge Float par d faut Vdc 13 80 27 60 55 2 Limites tension de sortie Vdc 8 16 11 32 22 64 Mini maxi Courbe de charge 4 tapes adaptative Courant nominal
51. 9 victron energy A y NORMAS DE SEGURIDAD General Antes de utilizar este equipo lea la documentaci n suministrada con este producto para familiarizarse con las instrucciones y medidas de seguridad Este producto ha sido dise ado y comprobado de acuerdo con las normas internacionales El equipo debe utilizarse exclusivamente para los fines para los que ha sido dise ado ADVERTENCIA PELIGRO DE DESCARGA EL CTRICA El producto se usa junto con una fuente de alimentaci n permanente bater a Los terminales de entrada y o salida podr an contener energ a peligrosa incluso cuando el equipo est apagado Deber desenchufarse siempre la alimentaci n CA y la bater a antes de llevar a cabo el mantenimiento o reparaci n del producto El producto no tiene componentes internos que puedan ser manipulados por el usuario No retire el panel frontal ni encienda el producto si cualquiera de los paneles ha sido retirado Cualquier reparaci n deber llevarla a cabo personal cualificado No utilice este producto en lugares con riesgo de explosi n de gas o polvo Consulte la informaci n del fabricante de la bater a para asegurarse de que el producto es compatible para su uso con la bater a Deber n cumplirse siempre las instrucciones de seguridad del fabricante ADVERTENCIA No levante cargas pesadas sin ayuda Instalaci n Lea atentamente las instrucciones de instalaci n en el manual de instalaci n antes de instalar el equipo
52. A rating of the MultiPlus Compact for ex a genset of at least 1500 VA will be required to operate in parallel with a Multi Compact 12 2000 80 Note 2 The output waveform of a generator can be heavily distorted In that case the AC waveform check should be disabled victron energy 3 Gul y 1 2 Chargeur de batteries Multi MultiPlus Compact uniquement Caract ristique de charge adaptative en 4 tapes Bulk Absorption Float Veille Le Multi MultiPlus Compact innove par son syst me de gestion de charge adaptative pilot e par microprocesseur et param trable selon les diff rents Typs de batteries La fonction adaptative optimise automatiquement le processus de charge l utilisation faite de la batterie La bonne dose de charge dur e d absorption variable Lorsque la batterie est peu sollicit e par exemple sur un bateau raccord au quai la phase de charge d absorption est raccourcie pour viter toute surcharge Apr s une d charge profonde la dur e de la charge d absorption est automatiquement allong e pour assurer une recharge compl te de la batterie Pr vention des d t riorations dues au gazage progression limit e de la tension Si pour obtenir une recharge rapide un courant lev a t associ une tension d absorption lev e le Multi MultiPlus Compact vite une d t rioration due au gazage en limitant automatiquement la progression de la tension d s que la tension de gazage e
53. DS 2 ps 4 DS 3 pes DS 4 DS 6 Hoff DS 5 DS 7 DS 6 pss DS 7 DS 8 DS6 off normal Store the settings DS6 by changing the DS8 switch DS6 on economy position off to on and then back to off AC input current limit DS 1 DS 2 DS 3 DS 4 DS 5 DS 6 DS 7 DS 8 on me DS 1 DS 2 DS 3 DS 4 DS 5 DS 6 DS 7 E on x DS 8 DS7 off DS7 on limit 30 Amp limit 6 Amp Store the settings DS7 by changing the DS8 switch position off to on and then back to off 16 AD y victron energy 4 3 The adaptive charge curve Charge current 120 100 80 Amps 60 40 20 0 Time Volts H E Charge voltage 16 E 64 32 Battery Safe 15 i inode Max Absorption time 60 30 56 28 i f Ge gt Time gt e e gt gt Bulk hours Absorption 1 day 7 daysreduced 7days float float reduced gt i 1 hour Repeated Absorption 4 stage charging p E Bulk mode Entered when charger is started Constant current is applied until the gassing voltage is reached 14 4V resp 28 8V temperature compensated Battery Safe Mode If in order to quickly charge a battery a high charge current in combination with a high absorption voltage has been chosen the Multi Compact MultiPlus Compact will prevent damage due to excessive gassing by automatically limiting the rate of voltage incre
54. Die Gasungsspannung ist auf einen falschen Wert eingestellt Stellen Sie die Gasungsspannung auf den f r Ihren Batterietyp richtigen Wert ein Die Ladeerhaltungsspannung ist auf einen falschen Wert eingestellt Stellen Sie die Ladeerhaltungsspannung auf den f r Ihren Batterietyp richtigen Wert ein Die Gleichstromausgangs sicherung ist durchgebrannt Der Inverter ist beschadigt Wenden Sie sich an einen Victron Energy Handler Die Batterie wird berladen Die Gasungsspannung ist auf einen falschen Wert eingestellt Stellen Sie die Absorptionsspannung auf den f r Ihren Batterietyp richtigen Wert ein Die Ladeerhaltungsspannung ist auf einen falschen Wert eingestellt Stellen Sie die Ladeerhaltungsspannung auf den f r Ihren Batterietyp richtigen Wert ein Die Batterie ist beschadigt Wechseln Sie die Batterie aus Die Batterie ist zu klein Verringern Sie den Ladestrom oder setzen Sie eine Batterie mit h herer Kapazit t ein Die Batterie ist zu warm Schlie en Sie einen Temperaturf hler an Der Ladestrom f llt auf 0 sobald die Gasungsspannung erreicht ist 1 Batterietemperatur ber 50 C Lassen Sie die Batterie abk hlen Stellen Sie die Batterie in eine k hlere Umgebung berpr fen Sie die Batterie auf Zellenkurzschl sse 2 Batterief hler ist ausgefallen Stecken Sie den Batterietem peraturf hler am Phoenix Multi Compact
55. Este producto es un dispositivo de clase de seguridad suministrado con terminal de puesta a tierra Los terminales de entrada y o salida CA deber n conectarse a tierra de manera permanente Tambi n se podr utilizar el punto de puesta a tierra ubicado en la parte externa del producto Si sospecha que la puesta a tierra pueda estar da ada deber desconectar el equipo y asegurarse de que no se puede poner en marcha de forma accidental p ngase en contacto con personal t cnico cualificado Compruebe que los cables de entrada CC y CA disponen de fusibles y de disyuntores No sustituya nunca un componente de seguridad con uno de otro tipo Consulte el manual para determinar cu l es el componente adecuado Antes de conectarlo a la corriente aseg rese de que la fuente el ctrica disponible coincide con la configuraci n del producto descrita en el manual Compruebe que el equipo se utiliza en las condiciones ambientales correctas No utilice el producto en un ambiente h medo o polvoriento Compruebe que hay suficiente espacio alrededor del producto para su ventilaci n y que los orificios de ventilaci n no est n bloqueados Compruebe que la tensi n necesaria para el sistema no exceda la capacidad del producto victron energy 1 O y Transporte y almacenamiento Aseg rese de que los cables de alimentaci n y los de la bater a han sido desconectados para su almacenamiento o transporte No se aceptar ninguna responsabilidad por
56. Plus Compact eine Reihe von wegweisenden Leistungsmerkmalen mit denen ganz neue Anwendungsbereiche abgedeckt werden k nnen Automatisch und unterbrechungsfrei umschalten nur Phoenix Multi Compact MultiPlus Compact Im Falle eines Netzfehlers oder einer Unterbrechung des Landstroms oder Bordgenerators wird der Wechselrichter des Phoenix Multi Compact MultiPlus Compact automatisch eingeschaltet und bernimmt die Versorgung der angeschlossenen Verbraucher Die Umschaltung geschieht so schnell in weniger als 20 Millisekunden dass ein unterbrechungsfreier Betrieb von Computern und anderen elektronischen Ger ten gew hrleistet ist PowerControl Arbeiten mit begrenzter Generatorleistung oder eingeschr nktem Landstrom nur Phonix Multi Compact MultiPlus Compact Der Phonex Multi Compact MultiPlus Compact Multi Compact verf gt ber ein Batterieladeger t mit hoher Leistung Deshalb zieht er eine Menge Strom vom Generator oder Landanschluss fast 8 A am 230V Netz Mit dem Fernbedienungspanel Phoenix Multi Control kann der maximal zu entnehmende Netz bzw Generatorstrom eingestellt werden Der Phoenix Multi Compact MultiPlus Compact nimmt dann R cksicht auf weitere angeschlossene Wechselstromverbraucher und nutzt zum Laden nur den Strom der noch brig ist So wird verhindert dass der Generator oder der Landstromanschluss berlastet wird PowerAssist Leistungssteigerung von Generatoren und Landanschlussunterst tzung
57. a 3 6 Opciones de conexi n Existen varias opciones de connexion distintas Quite los cuatro tornillos de la parte frontal de la carcasa y retire el panel frontal 3 6 1 Bater a auxiliar El Phoenix Multi Compact MultiPlus dispone de una conexi n para cargar una bater a de arranque Para su conexi n ver Ap ndice 1 3 6 2 Sensor de temperatura Multi Compact MultiPlus Compact El sensor de temperatura suministrado con el producto puede utilizarse para cargas compensadas por temperatura El sensor est aislado y debe montarse en la polaridad negativa de la bater a Las tensiones de salida por defecto para Float y Absorption est n a 25 C En el modo de ajuste la compensaci n de temperatura est deshabilitada 15 0 145 14 0 13 5 13 0 Volts 12 5 12 0 11 5 11 0 10 5 10 0 0 5 10 15 20 25 30 35 40 45 50 55 60 Battery temperature 3 6 3 Panel de control remoto y conmutador on off remoto El producto puede manejarse de forma remota de dos maneras Por medio de un conmutador externo solamente Por medio del panel de control remoto Tenga en cuenta lo siguiente al usar s lo un conmutador externo S lo funciona si el conmutador del producto est en posici n on No debe conectarse si ya hay un control remoto conectado Tenga en cuenta lo siguiente al usar un control remoto S lo funciona si el conmutador del producto est en posici n
58. a en la posici n deseada despu s de estos pasos se puede volver a conmutar r pidamente una vez m s Esto no modificar el estado de carga 6 victron energy n N y 2 4 Indicadores LED O LED apagado xX LED intermitente O LED encendido Inversor inverter O on charger O off alarm O charger only inverter J on charger O i off alarm Le charger only inverter on charger O H off alarm charger only El inversor est en marcha y alimenta la carga Funciona con la bateria El inversor est en marcha y alimenta la carga Prealarma sobrecarga o tension de la bateria baja o temperatura del inversor baja El inversor est apagado Alarma sobrecarga o tension de la bater a baja o temperatura del inversor alta o Ondulaci n residual en el terminal de la bater a demasiado alta victron energy O y Cargador inverter O on charger J off alarm O charger only inverter on charger J off alarm J charger only inverter O o charger 2 off alarm O charger only inverter O on charger Eed off alarm O charger only 8 La tension de la red est transferida y el cargador funciona en modo bulk o absorption La tension de la red est transferida y el cargador est apagado El cargador de bater as no alcanza la bater a de fin de carga modo protecci n de bulk La tension de la red est transfe
59. aansprakelijkheid worden aanvaard voor transportschade indien de apparatuur wordt vervoerd in een andere dan de originele verpakking Sla het product op in een droge omgeving de opslagtemperatuur moet tussen de 20 C en 60 C liggen Raadpleeg de handleiding van de fabrikant van de batterij met betrekking tot vervoer opslag opladen herladen en verwijderen van de batterij 2 Ay y victron energy 1 BESCHRIJVING 1 1 Algemeen Multi Compact functioneel alleen Multi Compact MultiPlus Compact De basis van de Multi Compact is een zeer krachtige sinusomvormer acculader en omschakelautomaat in een compacte behuizing Daarnaast heeft de Multi Compact MultiPlus Compact een groot aantal vaak unieke mogelijkheden o a PowerControl en PowerAssist Automatisch en onderbrekingsvrij omschakelen alleen Multi Compact MultiPlus Compact In geval van een netspanningstoring of wanneer het aggregaat wordt uitgeschakeld zal de Multi Compact overschakelen van lader bedrijf op omvormer bedrijf en de voeding van de aangesloten apparaten overnemen Dit gaat zo snel dat computers en andere elektronische apparaten ongestoord blijven functioneren De maximale stroom die geschakeld kan worden bedraagt 30 A Multi Compact PowerControl Maximaal benutten van beperkte walstroom alleen Multi Compact MultiPlus Compact De Multi Compact kan enorm veel laadstroom leveren en dus grote accubatterijen laden Dat betekent een zware belasting voor de wa
60. acement Le Phoenix Multi Compact doit tre install dans un endroit sec et bien ventil le plus pr s possible des batteries M nagez autour de l appareil un espace minimum de 10 cm pour son refroidissement Une temp rature ambiante trop lev e aura pour cons quences Moindre dur e de vie Courant de charge r duit Puissance de pointe r duite ou un arr t total du convertisseur Ne jamais placer l appareil directement au dessus des batteries Le Phoenix Multi Compact est pr vu pour montage mural Voir appendice 0A L appareil peut tre mont horizontalement ou verticalement mais le montage vertical est pr f rable Le refroidissement est meilleur dans cette position A L int rieur de l appareil doit rester accessible m me apr s installation Assurez vous que les c bles de branchement soient quip s de fusibles et disjoncteur Maintenir la distance entre le Phoenix Multi Compact et les batteries aussi courte que possible afin de r duire les pertes de tension dans les c bles Pour des raisons de s curit cet appareil doit tre install dans un environnement r sistant la chaleur Ne pas utiliser l appareil proximit de produits chimiques carburants objets en mati re plastique mati res textiles ou toute autre mati re sensible la chaleur victron energy 11 Gul y 3 3 Outillage n cessaire Un tournevis cruciforme PH 2 Un tournevis plat 0 6x3 5 pour le raccordement des c bles AC C
61. acer DS8 de off a on puis a off Limitation du courant d alimentation DS7 DS 1 DS 2 DS 3 DS 4 DS 5 DS 6 DS 7 DS 8 DS 1 DS 2 DS 3 DS 4 DS 5 DS 6 DS 7 pese on ES DS 8 DS7 off DS7 on Limite 30 Amp Limite 6 Amp Validation D placer DS8 de off on puis a off victron energy Gul y 19 4 3 La courbe de charge Adaptative Charge current 120 100 80 Amps 60 40 20 0 Volts Charge voltage 64 32 20x dur e Bulk ou i dur e d Absorptiort maxi i 13 60 30 56 28 10 Y Time Dur e Bulk 1 jour 7 jours veille Float Absorption 7 jours veille NEEN dE q 1 heure Absorption r p t e Caract ristiques de la Charge a 4 tapes Mode Bulk Engag a la mise en marche du chargeur Charge courant constant jusqu la tension de gazage de la batterie 14 4V 28 8V 57 6V corrig e selon temp rature dur e variable selon tat de charge au d part Ensuite Mode Battery Safe Si une tension et une intensit lev es ont t choisies pour obtenir une charge rapide le Multi Compact MultiPlus r duit la vitesse de mont e en tension lorsque la tension de gazage est atteinte Ceci afin d viter un gazage excessif et pour prot ger la batterie Le mode BatterySafe est compt dans la dur e du Mode Absorption Mode Absorption Charge finale
62. acio de tiempo como pasa a menudo es posible reducir la potencia de generador necesaria o al contrario aumentarla para compensar la conexi n del pantal n casi siempre limitada Cuando se reduce la carga la potencia sobrante se utiliza para recargar la bater a Nota 1 Para un correcto funcionamiento del PowerAssist se requiere una corriente m nima del pantal n de 2 A o una capacidad del generador igual a la del Multi Nota 2 Algunos generadores CA modernos utilizan un inversor est tico para generar la CA de salida Algunos de estos generadores tambi n reducen las rpm al funcionar con una carga reducida Al habilitar la funci n Dynamic Current Limit l mite de la corriente din mica VEConfigure se puede utilizar el Multi Plus Compact para que ayude al generador en caso de conectarse una gran carga s bitamente Rel de alarma externa y conmutador virtual por defecto deshabilitado Hay una salida de colector abierto disponible para conectar un rel que puede utilizarse para una alarma remota y para otros fines como una se al de arranque del generador La tensi n corriente m xima conmutable transistor de colector abierto 66V 40mA La salida de colector abierto puede programarse con el VEConfigure 20 victron energy O y 4 6 Mantenimiento El Phoenix Multi Compact no necesita un mantenimiento espec fico Es sufienciente con comprobar anualmente todas las conexiones y eventualmente quitarle el polvo Proteja
63. ambiarse con los conmutadores DIP Tipo Tipo de bateria Tensi n absorption Tensi n float Tiempo m ximo de absorci n 1 Sonnenschein 14 4 V 28 8 V 57 6V 13 8 V 27 6 V 55 2 V 4 horas defecto Dryfit A200 Gel 13 2V 26 4 V 52 8 V 2 Tracci n 15 0 V 30 0 V 60 0 V 13 8 V 27 6 V 55 4 V 6 horas placa tubular 13 2 V 26 4 V 52 8 V 3 Semi tracci n 14 4V 28 8 V 57 6V 14 0V 28 0 V 56 V 5 horas placa plana 13 2 V 26 4 V 52 8 V 4 Bajo en 14 8 V 29 6 V 59 2 V 14 0 V 28 0 V 56 V 5 horas antimonio 13 2 V 26 4 V 52 8 V La tensi n optima de absorci n para bater as de plomo y cido de placa plana depende de las propiedades mec nicas y qu micas Las bater as con un alto contenido de antimonio normalmente pueden cargarse con una tensi n de absorci n m s baja que las bater as con bajo contenido de antimonio Le rogamos consulte nuestro libro Electricidad a Bordo que puede descargarse desde nuestro sitio web www victronenergy com para obtener m s datos y consejos sobre cargas de bater as P ngase en contacto con su proveedor de bater as para que le indique las tensiones de carga correctas y cambie con el VE configure las tensiones si fuese necesario El par metro de carga por defecto es el 75 de la corriente de carga m xima Esta corriente ser demasiado alta para la mayor a de las aplicaciones Para casi todos los tipos de bater a la corrien
64. ase once the gassing voltage has been reached The Battery Safe Mode is part of the calculated absorption time Absorption mode A constant voltage period to fully charge the battery The absorption time is equal to 20x bulk time or the set maximum absorption time whichever comes first Float mode Float voltage is applied to keep the battery fully charged and to protect it against self discharge Reduced Float After one day of Float charge a reduced Float charge is applied This is 13 2V resp 26 4V for 12V and 24V charger This will limit water loss to a minimum when the battery is stored for the winter season After an adjustable time default 7 days the charger will enter Repeated Absorption mode for an adjustable time default 1 hour victron ener Gul y gy 17 4 4 Setting the Charger Multi Compact MultiPlus Compact only 4 4 1 Preprogrammed charge curves can be changed with VEConfigure only Please refer to our book Electricity on Board downloadable from our website www victronenergy com for details and suggestions about charging batteries The Phoenix Multi Compact MultiPlus Compact has 3 pre programmed charge curves Fixed 3 state charge curve The absorption period is a fixed preset period Following the absorption mode the charger switches to float In order to refresh the battery the charger periodically switches back to absorption Adaptive charge curve The absorption period depends on the lengt
65. assis eines Fahrzeugs oder an der Erdungsplatte oder dem Rumpf eines Bootes angeschlossen werden Marine Anwendung Aufgrund der Gefahr galvanischer Korrosion ist es eigentlich unerw nscht die Landerde mit der Erdungsplatte oder dem Rumpf eines Bootes zu verbinden Eine gute und sichere L sung ist der Einbau eines Trenntrafos victron energy N y Der Netzeingangs und Ausgangsanschluss mit den den Steckern G ST18i befindet sich am Boden des Multi Compact S Anhang 1 Das Netz wird mit einem flexiblen Kabel 3 x 1 5 mm 600VA oder 3 x 2 5 mm 1600VA an den Stecker G ST18i angeschlossen Vorgehensweise Gehen Sie beim Anschlie en der Kabel wie folgt vor Das Kabel f r den Wechselstromausgang kann direkt mithilfe der G ST18i Stecker angeschlossen werden Die Anschlusspunkte sind deutlich gekennzeichnet Von links nach rechts N Neutral PE Erde und L1 Leiter Das Netzanschlusskabel kann direkt mit der G ST18i Anschlussdose angeschlossen werden Die Anschlusspunkte sind deutlich gekennzeichnet Von links nach rechts L1 Leiter PE Erde und N Neutral Stecken Sie die Netzanschluss G ST18i Steckerdose in den Einbausteckereingang n chst der R ckfront Stecken Sie den Wechselstromausgang Stecker in den Einbausteckdosen Ausgang n chst der Vorderfront 3 6 Weitere Anschlussm glichkeiten Eine Reihe weiterer Anschl sse ist m glich Dazu die vier Schrauben der Frontpanels des Geh uses l s
66. atisch Nominale startaccu 4 stroom A Toegestane accu rimpel Max 1 25 Vrms Acculekstroom wanneer lt 1mA de Multi Compact is uitgeschakeld mA 26 victron energy N y 6 4 Schakelen tussen omvormer en AC ingang Maximaal doorgeschakeld vermogen 6900W begrensd door een 30 A Thermal Circuit Breaker Omschakeltijd van omvormer naar netspanning Oms Omschakeltijd van netspanning naar omvormer 0 ms U batt gt 10 5V Netspanningfout detectie tijd 4ms tot 20ms Omschakelspanning AC ingang naar omvormer 180Vac Omschakelspanning van omvormer naar AC ingang 187Vac Min Max frequentie bereik 50Hz 60Hz 45 55Hz of 55 65Hz T Doordat de omvormer en netspanning een korte tijd parallel werken is er geen omschakeltijd 6 5 Mechanisch 12 800 12 1200 12 1600 24 800 24 1200 24 1600 48 1200 48 1600 135 50 70 116 125 140 112 120 12 800 12 1200 12 1600 24 800 24 1200 24 1600 48 1200 48 1600 Behuizing aluminium beschermingsklasse IP21 kleur blue RAL 5012 Afmetingen H x 375 mm x 215 mm x 115mm zie Anhang A W xD gewicht kg 9 10 10 9 10 10 10 10 Batterij 1 5m 1 5m 1 5m 1 5m 1 5m 1 5m 1 5m 1 5m aansluitkabel AC in out aansluiting 2 G ST18i connector 2 5 mm Startbatterij 1 5 mm draden Aansluitingen op printplaat aansluiting connector geschikt vo
67. batterie auxiliaire A 4 Ondulation de tension DC maxi Vrms Max 1 25 Courant de fuite batterie en position arr t mA lt 1mA 28 victron energy O y 6 4 Commutation automatique entre secteur AC et convertisseur Puissance maximale commut e W limit e par disjoncteur thermique 30 A 6900W D lai de commutation de convertisseur secteur Ooms D lai de commutation de secteur a convertisseur Batterie gt 10 5V Ooms D lai de d tection de d faut secteur 4a20mS Tension de commutation de secteur a convertisseur 180Vac Tension de commutation de convertisseur a secteur 187Vac Plage de fr quence mini maxi Hz 45 55Hz ou 55 65Hz Y En raison d un court fonctionnement en parall le du convertisseur et du secteur il n y a pas de d lai de commutation 6 5 M canique 12 800 12 1200 12 1600 24 800 24 1200 24 1600 48 1200 48 1600 135 50 170 116 125 135 112 120 12 800 12 1200 12 1600 24 800 24 1200 24 1600 48 1200 48 1600 Boitier Aluminium degr amp de protection IP21 Couleur Bleu RAL 5012 Dimensions e HxLxP mm 375 x 215 x 115 voir appendice A Poids kg 9 10 10 9 10 10 10 10 C ble de raccordement 1 5m 1 5 m 1 5 m 1 5 m 1 5 m 1 5 m 1 5 m 1 5 m batterie Raccordement entr e sortie 2 fiches G ST18i 2 5 mm 2P T AC Raccordement batterie Sur circuit imprim bor
68. carry the full output current The second output limited to approximately 4A and with a slightly lower output voltage is intended to top up a starter battery To increase battery life temperature compensation Every Multi Compact MultiPlus Compact comes with a battery temperature sensor When connected charge voltage will automatically decrease with increasing battery temperature This feature is especially recommended for sealed batteries and or when important fluctuations of battery temperature are expected Learn more about batteries and battery charging To learn more about batteries and charging batteries please refer to our book Electricity on Board available free of charge from Victron Energy and downloadable from www victronenergy com For more information about adaptive charging please look under Technical Briefs on our website 1 3 List of Article Numbers for Accessories Phoenix Multi control REC020002000 Phoenix Inverter control RECO30001000 Temperature sensor Tl ASS000001000 UTP Patch lead 5m ASS030065000 UTP Patch lead 10 m ASS030065010 UTP Patch lead 15 m ASS030065020 PC interface MK1 b ASS0301B0000 USB adapter ASS030200000 VEConfigure software Can be downloaded from our website 4 victron energy Gul y 2 OPERATION 2 1 On Off Charger Only Switch When the front switched to on the product is fully functional The inverter will come into operation and the LED inverter on will light up Multi Compact Mu
69. charger only and back The switch must be switched in such a way that the intermediate position is as it were skipped If the relevant switch remains in the off position for any length of time you may run the risk that the appliance will be switched off In that case you will need to start again Use a remote control for best results 1 Ensure that all switches i e front switch remote or remote control switch if present are switched to the on position 2 Ensure that the Phoenix Multi Compact is charging an AC input voltage must be present check that the charger LED is one only remote control mains of either the bulk absorption or float LEDs is illuminated 3 Switch the switch successively to charger only on and charger only NOTE the switching itself should be done quickly but the interval between switching should be from 1 2 to two seconds 4 The green front led bulk yellow front led absorption and red front led float LEDs will flash five times only remote control the bulk absorption and float LEDs will flash five times e _ Subsequently the green front led bulk yellow front led absorption and red front led float LEDs will each light up for a period of two seconds e Ifthe switch is switched to on while the green front led bulk LED illuminates the charger switches to the equalizing mode If the switch is switched to on while the yellow led absorption LED illuminates t
70. cial Settings can be changed with VEConfigure only Bulk Protection On Off default on If the charger has not reached the absorption voltage after 10 hours charging in the bulk phase the battery may be defective In order to prevent further damage the charger will automatically cut out after 10 hours bulk The bulk LED will start to flash Phoenix Inverter Control AC Waveform Check default on The Phoenix Multi Compact checks if the mains voltage has not only the correct voltage but also the correct shape When the Phoenix Multi Compact does not function properly on a generator this function can be disabled Note Additionally by disabling AC waveform check the AC low disconnect is ignored when the load current is higher than 1 5 times the AC input current limit This to prevent unnecessary switching to inverter due to a voltage drop when a high load is connected PowerControl Dealing with limited generator or shore side power The Multi Compact is a very powerful battery charger It will therefore draw a lot of current from the generator or shore side supply With the Phoenix Multi Control Panel PMV a maximum generator or shore current can be set The Multi Compact will then take account of other AC loads and use whatever is extra for charging thus preventing the generator or shore supply from being overloaded It is also possible to set the max generator shore current internally The generator shore current limit can
71. ct in een hittebestendige omgeving geinstalleerd worden Voorkom daarom de aanwezigheid van bijvoorbeeld chemicali n kunststof onderdelen gordijnen of ander textiel etc in de directe omgeving 10 A y victron energy 3 3 Benodigdheden Een kruiskop schroevendraaier PH 2 voor het verwijderen van het front Drie aderige kabel z 3 4 Aansluiten accukabels Om de capaciteit van de Phoenix Multi Compact volledig te kunnen benutten dient uitsluitend gebruik te worden gemaakt van accu s met voldoende capaciteit en van accukabels met de juiste dikte Zie tabel 24 800 24 1200 12 800 12 1200 12 1600 48 1600 24 1600 48 1200 Aanbevolen kabeldikte mm 15 gt 5m 16 25 35 50 70 5 gt 10m 35 50 70 100 140 1 standaard voorzien van 1 5m kabel 24 800 24 1200 12 800 12 1200 12 1600 48 1600 24 1600 48 1200 Aanpevoen 40 200 40 400 100 400 150 700 200 700 accucapaciteit Ah Opmerking Interne weerstand is een belangrijke factor als U werkt met lage capacitiet accu s Raadpleeg uw leverancier of relevante secties uit onze boek electriciteit aan boord downloadbaar van onze website Procedure Ga bij het aansluiten van de accukabels als volgt te werk Om het gevaar van kortsluiting van de accu te voorkomen dient u een ge soleerde pijpsleutel te gebruiken Voorkom kortsluiting van de accukabels Sluit de accukabel aan de rood aan linkerzijde Sluit de
72. de puesta a tierra ubicado en el exterior del producto deber usarse para poner a tierra la carcasa El cable de salida neutro deber conectarse a tierra para garantizar un buen funcionamiento del GFCI conmutador de circuito por fallo de puesta a tierra b Phoenix Multi MultiPlus Compact el cable neutro de salida se conectar autom ticamente al chasis con el rel de puesta a tierra de salida ver Ap ndice 2 cuando no haya disponible una fuente CA externa rel de retroalimentaci n seguridad abierto y el producto funcionando en modo inversor ver Ap ndice Cuando hay una fuente CA disponible el rel de puesta a tierra se abre antes de que el rel de retroalimentaci n seguridad se cierre Una vez cerrado el rel de retroalimentaci n seguridad garantiza que la conexi n entre neutro y tierra la efect e la conexi n CA externa Esto sirve para garantizar el funcionamiento correcto del GFCI que deber instalarse en la salida AC del Multi MultiPlus En una instalaci n fija como las terrestres la puesta a tierra permanente de la carcasa puede realizarse utilizando el cable de tierra de la entrada CA En el caso de las instalaciones m viles connexion a la entrada CA de un cable de red de pantal n la conexi n a tierra se pierde cuando se desconecta el cable de pantal n En este caso la carcasa del producto o la secci n de a bordo del cable de tierra de entrada debe desconectarse del bastidor del veh culo o de la p
73. de quai o la position du neutre est incertaine la coupure de l alimentation en entr e coupera galement la liaison la terre Dans ce cas le bo tier doit tre reli au chassis du v hicule ou la coque ou plaque de masse du navire La liaison la terre du quai d crite ci dessus est en g n ral d conseill e en vue des risques de corrosion galvanique Une bonne solution sera la mise en place d un transformateur d isolement victron energy 13 Gul y Le Phoenix Multi Compact est quip de fiches d entr e et de sortie de Typ G ST18i situ es sous l appareil Utiliser des c bles de raccordement souples 3 conducteurs Typ HO5RN F de section suffisante 1 5 mm jusqu 800VA et 2 5mm pour les puissances sup rieures Proc dure Proc der comme suit pour les raccordements AC Le c ble de sortie AC se raccorde sur la fiche m le G ST18i Utiliser un cable a trois conducteurs Les raccordements sont rep r s a l int rieur de la prise Gauche N neutre milieu terre droite L1 phase Le c ble d alimentation AC se raccorde sur la fiche femelle G ST18i Utiliser un c ble trois conducteurs Les raccordements sont rep r s a l int rieur de la prise Gauche L1 phase milieu terre droite N neutre Ins rer la fiche G ST18i d alimentation sur la prise m le de l appareil c t arri re Ins rer la fiche G ST18i de sortie sur la prise femelle de l appareil c t
74. den voor verschillende soorten accu s De adaptieve functie past het laadproces automatisch aan het gebruik van de accu De juiste hoeveelheid lading aangepaste absorptie tijd Bij geringe ontlading van de accu wordt de absorptie kort gehouden om overlading en overmatig gassen te voorkomen Na een diepe ontlading wordt de absorptie tijd automatisch verlengd teneinde de accu volledig te laden pa rm m victron energy 3 yy Beperking van veroudering door overmatig gassen begrensde spanningsstijging Indien om de laadtijd te verkorten gekozen wordt voor een hoge laadstroom en ook een verhoogde laadspanning dan zal de Phoenix Multi Compact MultiPlus Compact nadat de gasspanning bereikt is de stijgsnelheid van de spanning begrenzen Zo wordt overmatig gassen in de eindfase van de laadcyclus voorkomen Minder onderhoud en veroudering wanneer de accu niet gebruikt wordt de opslag functie De Phoenix Multi Compact MultiPlus Compact schakelt over op opslag wanneer er gedurende meer dan 24 uur geen ontlading plaatsvindt De spanning wordt dan verlaagd tot 2 2 V cel 13 2 V voor een 12 V accu De accu zal dan nauwelijks meer gassen en corrosie van de positieve platen wordt zoveel mogelijk beperkt Eens per week wordt de spanning verhoogd tot absorptie niveau om de accu weer bij te laden dit voorkomt stratificatie van het elektrolyt en sulfatering Twee uitgangen om 2 accu s te laden De Phoenix Multi Compact MultiPlus Compact h
75. dieningspaneel is aangesloten Voor het aansluiten van een afstandsbedieningspaneel zie Bijlage A Indien gebruik wordt gemaakt van een afstandsbedieningspaneel dient u met het volgende rekening te houden Werkt alleen als de schakelaar van de Phoenix Multi Compact op on staat 3 6 4 Extern Alarm Relais en Virtual Switch Er is een open collector uitgang beschikbaar waarop en relais aangesloten kan worden tbv alarm en andere signaleringen o a een generator start signaal De maximum belasting is 66V 40mA De functie van de open collector uitgang kan geprogrammeerd worden met VEConfigure 14 Md y victron energy 4 INSTELLINGEN Het wijzigen van de instellingen mag alleen worden uitgevoerd door een gekwalificeerde elektrotechnicus Lees voor het wijzigen goed de instructies E Tijdens het laden moeten accu s in een droge goed geventileerde ruimte staan m 4 1 Standaard instellingen Omvormer spanning 230 Vac Lader aan of uit aan on Laadcurve Adaptive charging gel accu s Laadstroom 75 van de nominale laadstroom Absorption spanning 14 4V 28 8V 57 6 Vdc Absorption Tijd Maximale Absorption tijd 4 uur Float spanning 13 8V 27 6V 55 2 Vdc Repeated Absorption Tijd 1 uur Repeated Absorption Interval 7 dagen Bulk Beveiliging on AC Waveform Check on PowerAssist alleen MultiPlus on Generator Shore Current 12A Systeem frequentie Multi Compact MultiPlus Compact automatisch Inverter Compact 50 Hz
76. du fabriquant des batteries pour vous assurer de la compatibilit des batteries avec l appareil Les consignes de s curit du fabriquant des batteries doivent toujours tre respect es ATTENTION Ne jamais soulever de charges lourdes sans aide Installation Lisez attentivement les consignes d installation avant de mettre l appareil en service Ce produit est class dans la classe de s curit livr avec prise mise la terre Une mise la terre permanente doit tre r alis e sur les bornes d entr e et ou de sortie du courant alternatif ou sur la borne de mise a la terre externe Si vous suspectez la protection par prise de terre d tre endommag e l appareil doit tre mis hors tension et prot g contre toute mise en service involontaire Adressez vous une personne qualifi e Assurez vous que tous les c bles de raccordement sont quip s de fusibles et disjoncteurs Ne jamais remplacer les protections par d autres d un Typ different Consultez les manuels pour utiliser protections appropri es Avant de mettre l appareil en service contr lez que la source de courant corresponde la configuration de l appareil tel que d crite dans le manuel Assurez vous que l appareil est utilis dans les conditions ambiantes correctes Ne jamais utiliser l appareil dans un environnement humide ou poussi reux victron energy 1 Gul y Conservez toujours suffisamment d espace libre autour de l appareil pour la vent
77. e 3 6 Aansluitopties Naast de standaardaansluitingen kunnen er nog een aantal opties worden aangesloten 3 6 1 Startaccu De Phoenix Multi Compact heeft een aansluiting voor het laden van een startaccu Zie voor het aansluiten appendix 1 victron ener 13 N y K 3 6 2 Temperatuursensor Multi Compact MultiPlus Compact Voor het temperatuur gecompenseerd laden kan de bijgeleverde temperatuursensor worden aangesloten zie Anhang A De sensor is geisoleerd en moet op de min pool van de accu worden gemonteerd De standaard uitgangsspanningen voor Float en Absorptie zijn 25 C Reduced Float spanning volgt de Float spanning en Raised Absorptie spanning volgt Absorptie spanning In de instel mode werkt de temperatuur compensatie niet 15 0 30 145 29 14 0 28 27 26 13 5 13 0 Volts 12 5 25 Volts 12 0 24 11 5 23 22 21 11 0 10 5 10 0 422 20 0 5 10 15 20 25 30 3 40 45 50 55 60 Battery temperature 3 6 3 Afstandsbediening De Phoenix Multi Compact is op twee manieren op afstand te bedienen Met alleen een externe schakelaar Met een Remote Control ofwel afstandsbedieningspaneel Voor het aansluiten van de schakelaar zie Bijlage A Indien gebruik wordt gemaakt van alleen een externe schakelaar dient u met het volgende rekening te houden Werkt alleen als de schakelaar van de Phoenix Multi Compact op on staat Mag niet worden aangesloten als er een afstandsbe
78. e des surcharges momentan es Toute puissance exc dentaire disponible en entr e est automatiquement utilis e pour la re charge de la batterie 22 AD y victron energy Note 1 Pour le bon fonctionnement de PowerAssist il faut disposer d au moins 2A au secteur quai ou d un groupe lectrog ne d une puissance au moins gale a celle du MultiPlus Note 2 Certains groupes lectrog nes modernes utilisent un convertisseur pour produire leur tension de sortie Inverter technology Certains de ces groupes diminuent aussi de r gime en cas de faible charge La fonction Dynamic current limit dans VEConfigure permet au MultiPlus d effacer des augmentations de puissance soudaines en attendant qu un groupe de ce Typ remonte en r gime Relais d Alarme externe et Commutateur Virtuel Une sortie collecteur ouvert est disponible pour raccorder un relayer un signal d alarme et d autres fonctions par exemple un signal de d marrage pour groupe lectrog ne La puissance maximale transistor collecteur ouvert est de 66V 40mA Les fonctions de la sortie collecteur ouvert sont param trables a l aide de VEConfigure 4 6 Entretien Le Phoenix Multi Compact ne n cessite pas d entretien sp cifique Contr ler l ensemble des connexions une fois par an et d poussi rez si n cessaire Prot ger l appareil contre l humidit les salissures et les fum es grasses victron energy 23 Gul y 5 RECHERCHE DE DEFAUTS Le
79. e blinkt Voralarm 4 Die Brummspannung ber der Eingangsgleichspannung ist h her als 1 25 V effektiv berpr fen Sie die Batteriekabel und deren Anschlussklemmen berpr fen Sie die Batteriekapazit t und erh hen Sie diese gegebenenfalls Die Alam LED Anzeige blinkt im Intervall Voralarm 5 Zu niedrige Batteriespannung und zu viele Verbraucher Laden Sie die Batterien und schalten Sie Verbraucher ab oder erweitern Sie Ihre Batteriekapazit t Verk rzen und oder verst rken Sie den Querschnitt Ihrer Batterie kabel victron energy N y 23 Problem Ursache L sung Die Alarm LED Der Inverter hat sich nach Gehen Sie noch einmal die Leuchtet einem Voralarm ausgeschaltet Fehlersuchtabelle durch Das Laderteil Die Eingangsspannung oder Stellen Sie sicher dass die funktioniert nicht Frequenz liegen au erhalb der vorgegebenen Werte Netzspannung zwischen 185 V und 265 V Wechselspannung liegt und dass die Frequenz den Einstellungen entspricht Der Sicherungsautomat hat ausgel st Stellen Sie den thermischen 30 A berstromschutzschalter zur ck 24 victron energy N y Problem Ursache L sung Die Batterie wird nicht voll geladen Falscher Ladestrom Stellen Sie den Ladestrom auf den 0 1 0 2 fachen Wert der Batteriekapazit t ein Schlechter Batterieanschluss Kontrollieren Sie die Batterieanschl sse
80. e must be between 20 C and 60 C Consult the battery manufacturer s manual in respect of transport storage charging recharging and disposal of the battery 2 victron energy Gul y 1 DESCRIPTION 1 1 General Multi Compact functional Multi Compact MultiPlus Compact only The Multi Compact gets its name from the multiple functions it can perform lt is a powerful true sine wave inverter a sophisticated battery charger that features adaptive charge technology and a high speed AC transfer switch in a single compact enclosure Beside these primary functions however the Multi Compact has several advanced features that provide a range of new applications as outlined below Uninterrupted AC power Multi Compact MultiPlus Compact only In the event of a grid failure or shore or generator power being disconnected the inverter within the Multi Compact is automatically activated and takes over supply to the connected loads This happens so fast less than 20 milliseconds that computers and other electronic equipment will continue to operate without disruption PowerControl Dealing with limited generator or shore side power Multi Compact MultiPlus Compact only The Multi Compact is a very powerful battery charger lt will therefore draw a lot of current from the generator or shore side supply nearly 8 A per Multi Compact at 230 VAC With the Phoenix Multi Control PMV a maximum generator or shore current can be set The Mult
81. ecarga de la bater a La tensi n de absorci n se ha fijado en un nivel incorrecto Fije la tensi n de absorci n al nivel correcto La tensi n de flotaci n se ha fijado en un nivel incorrecto Fije la tensi n de flotaci n al nivel correcto La bater a est defectuosa Cambie la bater a La bater a es demasiado Reduzca la corriente de carga o peque a utilice una bater a de mayor capacidad La bater a est demasiado Conecte un sensor de caliente temperatura La corriente de carga de la bater a cae a 0 al alcanzar la tensi n de absorci n Alt 1 Sobrecalentamiento de la bater a gt 50 C Deje que la bateria se enfrie Coloque la bater a en un lugar fresco Compruebe que no haya elementos cortocircuitados Alt 2 Sensor de temperatura defectuoso Desenchufe el sensor de temperatura del Multi Restablezca el Multi apag ndolo esperando 4 segundos y volvi ndolo a enchufar Si el Multi carga ahora normalmente el sensor de temperatura de la bater a est defectuoso y debe sustituirlo victron energy O y 23 6 INFORMACI N T CNICA 6 1 GENERAL Ventilaci n Convecci n forzada interna Temperaturas admitidas en funcionamiento 20 50 C en almacenamiento 25 60 C Protecci n Cortocircuito de salida Sobrecarga Tensi n de la bater a demasiado alta Tensi n de la bater a demasiado
82. eeft 2 uitgangen waarvan er 1 de volle uitgangsstroom kunnen leveren De tweede uitgang bedoeld voor het laden van een startaccu is begrensd op 4 A en heeft een iets lagere uitgangsspanning Verhogen van de levensduur van de accubatterij temperatuur compensatie Bij iedere Phoenix Multi Compact MultiPlus Compact wordt een temperatuursensor meegeleverd De temperatuur sensor zorgt ervoor dat de laadspanning afneemt wanneer de accutemperatuur stijgt Dit is bijzonder belangrijk voor onderhoudsvrije accu s die anders mogelijk door overladen uitdrogen Meer over accu s en acculaden In ons boek Elektriciteit aan boord kan U meer lezen over accu s en het laden van accu s gratis verkrijgbaar bij Victron Energy en beschikbaar op www victronenergy com Voor de adaptieve laadkarakteristiek zie ook onder Technical Information op onze website 1 3 Overzicht artikelnummers accessoires Phoenix Multi control REC020002000 Phoenix Inverter control REC030001000 Temperatuursensor ASS000001000 UTP Patch lead 5m ASS030065000 UTP Patch lead 10 m ASS030065010 UTP Patch lead 15 m ASS030065020 PC interface MK1 b ASS0301B0000 USB adapter ASS030200000 VEConfigure software Kunt u vanaf onze website downloaden 4 AD y victron energy 2 BEDIENING 2 1 On off charger only schakelaar Wanneer de schakelaar op on wordt geschakeld werkt het apparaat volledig De omvormer zal aanschakelen en de LED inverter on zal gaan branden Als er op de
83. elay open and product running in inverter mode see appendix 2 When an external AC source is provided the ground relay opens before closure of the backfeed safety relay Once closed the backfeed safety relay ensures that the neutral to ground bond is provided by the external AC source This is to ensure proper functioning of a GFCI to be installed in the AC output of the Multi MultiPlus In a fixed for example terrestrial installation an uninterrupted chassis ground may be provided by the AC input ground wire In case of a mobile installation connection to input AC with a shore power cord the ground connection is lost when the shore power cord is unplugged In this case the chassis of the product or the on board section of the input ground wire must be connected to the frame of the vehicle or the ground plate or hull of a boat Marine applications due to the potential for galvanic corrosion it is in general not acceptable to connect the shore side ground to the ground plate or hull of the boat The proper and safe solution is to install an isolation transformer victron ener Gul y gy 11 The mains input amp output terminal connector G ST18i can be found on the bottom of the Multi Compact see appendix 1 The shore or mains cable must be connected to the G ST18i connector with a three wire cable Use a three wire cable with a flexible core and a cross section of 1 5 mm 800VA to 2 5 mm 1600VA Procedure Proceed
84. ellt werden Wiederkehrende Konstantspannungsphase Um die Batterie aufzufrischen wird in der Ladeerhaltungsphase periodisch auf die Konstantspannung zur ckgeschaltet Wiederkehrende Konstantspannungszeit Grundeinstellung 1 Stunde Die Konstantspannungszeit kann in Schritten von 1 bis 72 Viertelstunden eingestellt werden Wiederkehrendes Konstantspannungszeitintervall Grundeinstellung 7 Tage Das wiederkehrende Konstantspannungszeitintervall kann in Tagesschritten von 1 bis 45 eingestellt werden 20 AD y victron energy 4 5 Spezielle Einstellungen kann nur mit VEConfigure ge ndert werden Konstantstromzeitbegrenzung ein aus Grundeinstellung ein Wenn der Lader nach 10 Stunden in der Konstantstromphase noch nicht die Gasungsspannung erreicht hat kann es sein dass die Batterie schon besch digt ist Um weitere Sch den zu verhindern wird der Lader nach 10 Stunden Konstantstrom automatisch ausgeschaltet In diesem Falle blinkt die gelbe LED Anzeige Netzeingangsspannungskontrolle Grundeinstellung ein Die Phoenix Multi Compact MultiPlus Compact kontrolliert nicht nur die korrekte Spannungsh he sondern auch die Sinus Form der Eingangswechselspannnung Arbeitet der Phoenix Multi Compact MultiPlus Compact nicht richtig mit einem Generator kann diese Funktion ausgeschaltet werden Achtung Wird die Netzeingangsspannungskontrolle ausgeschaltet so wird auch die Abschaltung bei zu niedriger Eingangsspannung nicht wirksam
85. empezar de nuevo desde el paso 1 Utilice un control remoto para obtener mejores resultados 1 Compruebe que todos los conmutadores es decir conmutador frontal remoto o el control remoto en su caso est n en la posici n on 2 Aseg rese de que el Phoenix Multi Compact est cargando A la entrada CA deber llegarle corriente compruebe que el LED mains on y uno de los LED bulk absorption o float est encendido 3 Cambie el conmutador sucesivamente a charger only on y charger only NOTA la conmutaci n en s debe hacerse r pidamente pero el intervalo entre cada conmutaci n deber tener una cadencia de entre medio segundo y dos segundos 4 El led frontal verde bulk led frontal amarillo absorci n y led frontal rojo float parpadear n cinco veces s lo en el control remoto los LED bulk absorption y float parpadear n cinco veces e A continuaci n cada uno de los LED led frontal verde bulk led frontal amarillo absorci n y led frontal rojo float se encender n durante un periodo de dos segundos e Si el conmutador est en posici n on mientras el led frontal verde bulk se ilumina el cargador cambia al modo igualaci n e Siel conmutador est en posici n on mientras se enciende el LED led frontal amarillo absorci n el cargador cambia a absorci n forzada Si el conmutador no estuvier
86. en 3 6 1 Starterbatterie Der Phoenix Multi Compact Multi Plus Compact ist mit einem Anschluss zum Laden von Starterbatterien ausgestattet Zum Anschlie en siehe Anhang 1 14 My y victron energy 3 6 2 Temperaturf hler Multi Compact MultiPlus Compact Um beim Laden unterschiedliche Temperaturen zu ber cksichtigen zu k nnen liegt dem Ger t ein Temperaturf hler bei Der F hler ist isoliert ausgef hrt und muss am Minuspol befestigt werden Die voreingestellten Spannungswerte f r die Gasungs und Ladeerhaltungsspannung beziehen sich auf 25 Celsius W hrend des Einstellens bleibt die Temperaturkompensation ausgeschaltet 15 0 14 5 14 0 13 5 13 0 Volts 12 5 12 0 11 5 11 0 10 5 10 0 0 5 10 15 20 25 30 35 40 45 50 55 60 Battery temperature 30 29 28 27 26 25 24 23 22 21 20 Volts 3 6 3 Fernbedienungsschalter und Phoenix Multi Control Fernbedienungsschalttafel Das Ger t l sst sich auf zweierlei Art und Weise fernbedienen Entweder nur mit einem externen Schalter oder mithilfe des Phoenix Multi Control Fernbedienungspanels Wenn Sie nur mit einem externen Schalter arbeiten sollten Sie Folgendes ber cksichtigen Diese Betriebsart ist nur m glich wenn der Schalter am Ger t auf on steht Er darf nicht angeschlossen werden wenn bereits eine Phoenix Multi Control angeschlossen ist Zum Anschlie en der Fernbedienungsschalttafel
87. enzt durch 30 A Sicherungsautomat Umschaltzeit von Inverter auf Netzspannung O ms Umschaltzeit von Netzspannung auf Inverter Oms Batteriespannung gt 10 5V Reaktionszeit bei Ausfall der Eingangsspannung ms to 20ms Umschaltspannung Netzspannung auf Inverter 180 V Umschaltspannung Inverter auf Netzspannung 187 V Frequenzbereich 45 55Hz of 55 65Hz Der Inverter lauft parallel mit der Netzspannung 6 5 Gehausedaten und Anschlusstechnik 12 800 12 1200 12 1600 24 800 24 1200 24 1600 48 1200 48 1600 135 150 170 116 125 135 112 120 12 800 12 1200 12 1600 24 800 24 1200 24 1600 48 1200 48 1600 Geh use Aluminium Schutzklasse IP21 Farbe blau RAL 5012 Abmessungen 375 mm x 215 mm x 115 mm siehe Anhang A HxBxT Gewicht kg 9 10 10 9 10 10 10 10 Batterie 1 5 m 1 5 m 1 5 m 1 5 m 1 5 m 1 5 m 1 5 m 1 5 m anschlusskabel Wechselstroman schl sse Ein 2 G ST18 Stecker 3 Anschlussklemmen bis 2 5 mm Ausgang Starterbatterie 2 Anschlussklemmen auf der Leiterplatte bis 1 mm anschluss Anschl sse f r Fernbedienungsschalter 3 Anschlussklemmen bis 1mm F hler Fern bedienungs Batterietemperaturf hler 2 Anschlussklemmen bis 1mm schalter Alarm Transistorschaltausgang 66V 40mA 2 Anschlussklemmen bis 0 5mm Serielle F r Phoenix Remote Control oder Schnittstelle F r MK1 b mit VEConfigure Software UTP Anschluss 2
88. er Batteriekapazit t als optimal angesehen Einstellen der Dip Switch Schalter DS 1 DS 2 DS 3 DS 4 DS 5 DS 6 DS 7 DS 8 GE Ess Bee o o mn DS 1 Hoff DS 2 DS 3 DS 4 DS 5 DS 6 DS 7 DS 8 DS1 off Bei Verwendung von Phoenix Multi Control DS 2 off DS 1 wird nicht verwendet und soll in der off Position stehen Auswahl des Batterietyps DS 1 DS 2 f on DS 3 DS 4 Moff DS 5 DS 6 DS 7 DS 8 DS 1 DS 2 DS 3 DS 4 DS 5 DS 6 DS 7 DS 8 DS3 0ff DS4 off DS3 on DS4 off DS3 off DS4 on DS3 on DS4 on Typ 1 Gel Sie k nnen die Einstellungen DS3 DS4 speichern Typ 2 Typ 3 Typ 4 indem Sie die Position des Schalters DS8 zuerst von off nach on und dann wieder zur ck nach off stellen victron ener A y ai 17 Inverterfrequenz DS 1 DS 2 DS 3 DS 4 DS 5 DS 6 DS 7 DS 8 on f BEER EN DS 1 DS 2 DS 3 DS 4 DS 5 DS 6 DS 7 DS 8 DS5 off DS5 on 50Hz 60Hz Sie k nnen die Einstellungen DS5 speichern indem Sie die Position des Schalters DS8 zuerst von off nach on und dann wieder zur ck nach off stellen Economy Spar Betrieb DS 1 DS 2 DS 3 DS 4 DS 5 DS 6 DS 7 DS 8 o o DS 1 DS 2 DS 3 DS 4 DS 5 DS 6 DS 7 DS 8 DS6 off DS6 on normal economy Sie k nnen die Einstellungen DS6 speichern indem Sie die Position des Schalter
89. erter 50 Hz Sparschaltung aus 4 2 Einstellungen die mit den Dipswitch Schaltern ge ndert werden k nnen Typ Batterietyp Gasungsspannung Ladeerhaltungsspannung Maximale Konstants pannungs phase 1 Sonnenschein 144V 288 57 6 13 8 27 6 V 55 2V 4 Stunden Grund Dryfit A200 Gel V Vv VI 26 4V 52 8V einstellung 13 2V 2 Traktionsbatterie 15 0 V 30 0 60 0 13 8 27 6 V 55 4V 6 Stunden R hrchen V V Vi 26 4V 52 8V batterie 13 24 3 Semitraktions 144V 288 57 6 140 28 0 V 56V 5 Stunden Batterie Gitter V V Vi 26 4V 52 8V Platte 13 2V 4 Antimonarme 148V 296 59 2 14 0 28 0 V 56V 5 Stunden Batterie V V Vi 26 4V 52 8V 13 2V Die optimale Absorptionsspannung f r Bleis urebatterien mit Plattenaufbau h ngt von deren mechanischen und chemischen Eigenschaften ab Batterien mit einem hohen Antimongehalt k nnen im Allgemeinen mit einer niedrigeren Gasungsspannung geladen werden als Batterien mit einem niedrigen Antimongehalt Siehe das Buch Strom an Bord auf der Webseite www victronenergy com Fragen Sie Ihren Batterielieferanten nach der empfohlenen Spannung und korrigieren Sie mit VEConfigure ggf die Einstellungen wenn notwendig Die Grundeinstellung f r den Ladestrom betr gt 75 des 16 My y victron energy Maximalstroms F r viele Anwendungen ist dieser Strom immer noch zu hoch F r die meisten BatterieTypn wird ein Strom von 10 20 ihr
90. es Compruebe la capacidad de la bater a aum ntela si fuese necesario El LED de alarma parpadea de manera intermitente Prealarma 5 Baja tensi n de bater a y carga excesiva Cargue las bater as reduzca la carga o instale bater as de mayor capacidad Use cables de bater a m s cortos y o m s gruesos El LED de alarma est encendido El inversor se cort despu s de una prealarma Compruebe la tabla para tomar la acci n m s apropiada 22 victron energy O y Problema El cargador no funciona Causa Soluci n La tensi n o frecuencia CA de entrada est fuera de l mites Aseg rese de que la tensi n de entrada est entre 185 VCA y 265 VCA y que la frecuencia coincide con la establecida El disyuntor t rmico ha saltado Restablezca el disyuntor t rmico de 16 A La bater a no se est cargando completamente Corriente de carga incorrecta Establezca la corriente de carga entre 0 1 y 0 2 veces la capacidad de la bater a Una conexi n de la bater a est defectuosa Compruebe las conexiones de la bater a La tensi n de absorci n se ha fijado en un nivel incorrecto Fije la tensi n de absorci n al nivel correcto La tensi n de flotaci n se ha fijado en un nivel incorrecto Fije la tensi n de flotaci n al nivel correcto El fusible CC interno est defectuoso El inversor est estropeado Sobr
91. est si rapide moins de 20 millisecondes que le fonctionnement d ordinateurs ou d autres quipements lectroniques sensibles raccord s ne seront pas perturb s PowerControl La parade aux puissances limit es du quai ou d un groupe Multi Compact MultiPlus Compact seulement Le Multi Compact comporte un chargeur de batterie tr amp s puissant qui demande de fortes intensit s aux branchements quai pr s de 8 A en 230 Vac par Multi Compact Le tableau de commande Phoenix Multi Control PMV permet de limiter la puissance a fournir par le quai Le Multi Compact prend alors en compte la demande de puissance AC en sortie et n utilisera que l exc dent pour la charge vitant ainsi toute surcharge du quai ou d un groupe lectrog ne PowerAssist Davantage de puissance que le quai ou le groupe PowerAssist est une fonction suppl mentaire qui distingue le MultiPlus Compact du Multi Compact Le MultiPlus travaille en parall le avec la source d alimentation groupe lectrog ne prise de quai et permet de doubler la puissance disponible lorsque la limite fix e voir PowerControl est d pass e le convertisseur du MultiPlus fournit le compl ment partir de la batterie Il est ainsi possible de faire face des surcharges momentan es Toute puissance exc dentaire disponible en entr e est automatiquement utilis e pour la re charge de la batterie Note 1 The rating of the generator should be 75 or higher compared to the V
92. evariante l dt der Phoenix Multi Compact MultiPlus Compact w hrend der eingestellten maximalen Konstantspannungszeit mit der jeweiligen Gasungsspannung Die LED Anzeige absorption leuchtet auf nur an der Phoenix Multi Control E Auf diese Ladekennlinie kann der Phoenix Multi Compact MultiPlus Compact sowohl mit den Fernbedienungen als auch mit dem Schalter auf der Frontabdeckung eingestellt werden Voraussetzung daf r ist dass alle Schalter Front Fernbedienung und Phoenix Remote Control auf on stehen und keiner in der charger only Position Um den Phoenix Multi Compact MultiPlus Compact entweder auf Konstantspannungs oder Augleichsladen einzustellen m ssen Sie die nachfolgend beschriebenen Schritte durchf hren ACHTUNG Das unten beschriebene Umschalten von on auf charger only und zur ck muss schnell geschehen Dabei muss der Schalter so umgelegt werden dass die mittlere Stellung Ubersprungen wird Wenn der betreffende Schalter auch nur kurz in Stellung off steht kann sich das Ger t ausschalten In diesem Fall m ssen Sie wieder bei Schritt 1 beginnen Am besten geht es mit der Phoenix Remote Control 1 Achten Sie darauf dass alle Schalter also Frontschalter Fernbedienungsschalter oder Phoenix Remote Control Schalter sofern vorhanden auf on stehen 2 Sorgen Sie daf r dass der Phoenix Multi Compact Multi Plus Compact l dt Es muss eine Eingangswechselspannung vorhanden sein und Sie m ssen sich vergewisse
93. fnet DC zekering Fusible DC ANL Gleichstrom Fusible CC sicherung J Dubbelwerkende Convertisseur Wandler Lader Conversor bidireccional omvormer bidirectionnel verbindung K Behuizing moet Mise la terre Schutzerdungs Puesta a tierra permanent met de aarde zijn verbonden permanente du bo tier anschluss am Geh use muss mit dem Chassis eines Fahrzeugs oder dem Erdungspunkt eines Bootes verbunden sein permanente de la carcasa victron ener A y 2 xipuaddy Dimensions Afmetingen Dimensions Abmessungen tonnes 75mm Mounting hole E Bevestigings gaten Trous de fixation Befestigungsl che 6mm max Mounting plate e Montageplaat Plaque de montage 50mm Montageplatte gt My victron energy Victron Energy Blue Power Distributor Serial number Version 05 Date 11 August 2006 Victron Energy B V De Paal 35 1351 JG Almere PO Box 50016 1305 AA Almere The Netherlands General phone 31 0 36 535 97 00 Customer support desk 31 0 36 535 97 03 Fax 31 0 36 535 97 40 E mail sales victronenergy com www victronenergy com
94. gnora la desconexi n por CA baja cuando la corriente de carga sea superior a 1 5 veces el l mite de corriente de entrada CA Esto se hace para evitar conmutar innecesariamente al inversor debido a una ca da de la tensi n cuando se conecta una carga alta PowerControl Potencia limitada del generador o del pantal n El Multi Compact es un cargador de bater as muy potente Por lo tanto demandar una gran cantidad de corriente del generador o del pantal n En el panel Phoenix Multi Control PMV puede establecerse una corriente m xima proveniente del generador o del pantal n El Multi Compact tendr en cuenta las dem s cargas CA y utilizar la corriente sobrante para la carga evitando as sobrecargar el generador o la red del pantal n Tambi n es posible establecer la corriente m xima proveniente del generador pantal n internamente El l mite de corriente del generador pantal n puede establecerse entre 2 y 16 A Los ajustes realizados con el panel de control remoto anula los ajustes internos PowerAssist Capacidad el ctrica complementaria para el pantal n o generador s lo MultiPlus por defecto on La caracter stica que distingue al Phoenix MultiPlus Compact del MultiPlus Compact est ndar es la funci n PowerAssist Esta funci n lleva el principio de PowerControl a otra dimensi n permitiendo que MultiPlus complemente la capacidad de la fuente alternativa Cuando se requiera un pico de potencia durante un corto esp
95. gy Gul y 6 4 AC input switch Maximum AC switch power 6900 W protected by 30 A Thermal Circuit Breaker Switch over time inverter to AC input Oms Switch over time AC input to inverter U batt gt 10 5 V Oms Detection time AC input fault 4 ms to 20 ms Trip level mains to inverter 180 VAC Trip level inverter to mains 187 VAC Min Max frequency range 50 Hz 60 Hz 45 55 Hz or 55 65 Hz Inverter runs parallel with the AC input 6 5 Mechanical 12 800 12 1200 12 1600 24 800 24 1200 24 1600 48 1200 48 1600 135 50 170 116 125 40 112 120 12 800 12 1200 12 1600 24 800 24 1200 24 1600 48 1200 48 1600 Cabinet Aluminum protectin class IP21 Color Blue Ral 5012 Dimensions HxWxD 375 mm x 215 mm x 115 mm see App A Weight kg 9 10 10 9 10 10 10 10 Battery connection 15m 1 5m 1 5m 1 5m 1 5m 1 5m 1 5m 1 5m cable AC in out Connection 2 G ST18i connector 2 5 mm Start battery Terminals on printe board connector suitable for 1mm wires connection External connection Remote switch connector for 3 wire 1mm sensing Battery temperature sensor connector for 2 wire 1mm remote switch Alarm transistor open collector 66 40mA connector for 2 wire 0 5 mm Serial interface UTP For Phoenix Remote Control connector For Mk 1 with VEConfigure software 25 victron energy Gu
96. h of the bulk charge period see par 4 3 This is followed by a float phase lasting 24 hours after which the voltage is reduced by an additional 0 8 V resp 1 6 V for 12 V resp 24 V batteries reduced float As with the Fixed charge curve the charger will periodically switch back to absorption Adaptive charge curve with BatterySafe mode default setting If in order to quickly charge a battery a high charge current in combination with a high absorption voltage has been chosen the Phoenix charger will prevent damage due to excessive gassing by automatically limiting the rate of voltage increase once the gassing voltage has been reached 4 4 2 Other settings Absorption time default 4 hours The Absorption setting defines the fixed absorption period in the case of the fixed charge curve and the maximum absorption time in the case of the adaptive charge curve The maximum absorption time can be set from 1 to 8 hours Float Voltage default 14 4V 28 8V The float voltage can be set from 12V to16V respectively from 24V to 32V in 0 05V increments Repeated Absorption When in float the charger will periodically switch back to Absorption to refresh the battery Repeated Absorption Time default 1 hour The repeated absorption time can be set from 1 to 72 quarters of an hour Repeated Absorption Interval default 7 days The repeated absorption interval can be set from 1 to 45 days 18 AD y victron energy 4 5 Spe
97. he AC input voltage is switched through off and the charger operates in float mode alarm O charger only Phoenix Remote Control panel optional PowerControl inverter on re mains on overload O bulk low battery O absorption temperature O float on O charger only off Note When the LED s overload and low battery are on simultaneously the Multi Plus or Inverter Compact has switched off due to excessive DC ripple voltage 8 AD y victron energy 3 INSTALLATION AN This product should be installed by a qualified electrician 3 1 Box Contents Phoenix Multi Compact MultiPlus Compact or Inverter Compact User manual Installation manual Bag containing connection items i e Mounting plate Screws 5 Temperature sensor Charging current warning sticker 3 2 Location The product must be installed in a dry and well ventilated area as close as possible to the batteries There should be a clear space of at least 10 cm around the appliance for cooling Excessively high ambient temperature will result in the following Reduced service life AN Reduced charging current Reduced peak capacity or shutdown of the inverter Never mount the appliance directly above the batteries The product is suitable for wall mounting For mounting see Anhang A The appliance can be mounted horizontally as well as vertically vertical mounting is preferable The vertical position offers optimum cooling The
98. he charger switches to Forced Absorption If the switch is not in the required position after these steps H can be simply switched one more time This will not change the charging status 6 AD y victron energy 2 4 LED Indications O LED off Xe LED flashes O LED illuminated Inverter inverter O on charger O off alarm O charger only inverter J on charger O 8 off alarm Ee 3 charger only inverter on charger O off alarm charger only The inverter is switched on and supplies power to the load Battery operation The inverter is switched on and supplies power to the load Pre alarm overload or battery voltage low or inverter temperature high The inverter is switched off Alarm overload or battery voltage low or inverter temperature hig or DC ripple voltage on battery terminal was too high victron energy Gul y Charger inverter O on The AC input voltage is switched through charger ff and the charger operates in bulk or alarm O Q absorption mode charger only inverter on The AC input voltage is switched through charger o il and the charger is switched off off The battery charger can not reach battery alarm o end voltage bulk protection mode charger only inverter O on The AC input voltage is switched through charger o ff and the charger operates in bulk or alarm O 9 absorption mode charger only inverter O n charger xe fl T
99. i Compact will then take account of other AC loads and use whatever is extra for charging thus preventing the generator or shore supply from being overloaded PowerAssist Boosting the capacity of shore or generator power The feature that distinguishes the Phoenix MultiPlus Compact from the standard Multi Compact is PowerAssist This feature takes the principle of PowerControl to a further dimension allowing the MultiPlus Compact to supplement the capacity of the alternative source Where peak power is so often required only for a limited period it is possible to reduce the size of generator needed or conversely enable more to be achieved from the typically limited shore connection When the load reduces the spare power is used to recharge the battery Note 1 The rating of the generator should be 75 or higher compared to the VA rating of the MultiPlus Compact for ex a genset of at least 1500 VA will be required to operate in parallel with a Multi Compact 12 2000 80 Note 2 The output waveform of a generator can be heavily distorted In that case the AC waveform check should be disabled 1 2 Battery Charger Multi Compact MultiPlus Compact only Adaptive 4 stage charge characteristic bulk absorption float storage The Phoenix Multi Compact MultiPlus Compact features a microprocessor controlled adaptive battery management system that can be preset to suit different Typs of batteries The adaptive feature
100. i Control Panel betrieben werden Diese Bedientafel hat einen Schalter und weitere Anzeigen Die Ladefunktion des Phoenix Multi Compact MultiPlus Compact kann auch ausgeschaltet werden Dies ist ber eine Einstellung m glich oder ber die Phoenix Inverter Control Fernbedienung Eingangswechselstrom auf O setzen oder beim Anschluss eines Computers an den Phoenix Multi Compact MultiPlus Compact Mit MK1 b mit VEConfigure F r die Fernbedienung des Phoenix Inverter Compact muss ein eigenes das Phoenix Inverter Control Panel verwendet werden 2 3 Spezielle Ladekennlinie mit Ausgleichsladespannungsphase equalizing Manche Batterien brauchen regelm ig eine Ausgleichsladung Der Phoenix Multi Compact kann zu diesem Zweck mit h herer Spannung 1 V ber der Gasungsspannung f r eine 12 V Batterie 2 V f r eine 24 V Batterie f r die Zeitdauer einer Stunde arbeiten Der Ladestrom ist dann auf 1 4 des eingestellten Wertes begrenzt Ist eine Phonenix Multi Control angeschlossen blinken die LED Anzeigen bulk und absorption abwechselnd 6 My y victron energy W hrend einer Ausgleichsladung wird eine h here Ladespannung abgegeben als die meisten Gleichstromverbraucher vertragen k nnen Sie m ssen daher erst abgeschaltet werden bevor mit der Ausgleichsladung begonnen wird Laden mit Konstantspannung Manche Betriebsweisen erfordern es die Batterie f r einen bestimmten Zeitraum mit konstanter Spannung zu laden In dieser Lad
101. i Plus Compact die Geschwindigkeit des Spannungsanstiegs Konstantspannungsphase Absorption Mode Die Konstantspannungsphase gew hrleistet die Vollladung einer Batterie Die Konstantspannungsphasenzeit 20 x Konstantstromphasenzeit oder einer vorbestimmten maximalen Konstantspannungszeit Ladeerhaltungsphase Float Mode Ladeerhaltungsspannung h lt die Batterie im vollgeladenen Zustand und verhindert die Selbstentladung Die reduzierte Ladeerhaltungspannung Nach einem Tag im Ladeerhaltungs Modus ohne Stromentnahme wird eine reduzierte Ladeerhaltungsspannung von 13 2V resp 26 4V f r 12V und 24V Lader angelegt Hierdurch wird Wasserverlust minimiert wenn die Batterie z B w hrend der Winterzeit au er Betrieb genommen wird Nach einer vorbestimmbaren Zeit Grundeinstellung 7 Tage wird wiederum f r eine vorher zu bestimmende Zeit Grundeinstellung 1 Stunde mit Konstantspannung geladen victron ener 19 N y W 4 4 Einstellung des Ladeteils f r Phoenix Multi Compact MultiPlus Compact 4 4 1 Vorprogrammierte Ladekennlinien k nnen nur mit VEConfigure ge ndert werden Lesen Sie in unserer Brosch re Strom an Bord die Sie auf unserer Webseite www victronenergy com runterladen k nnen nach wie Sie am besten Ihre Batterien laden k nnen Beim Phoenix Multi Compact Multi Plus Compact haben Sie die Auswahl aus 3 vorprogrammierten Ladekennlinien Festgelegte Ladekennlinie ist gekennzeichnet durch eine bestimmte fe
102. idsfactor Alles toegestaan Economy DS6 on 145VAC top 300V load lt 25W speciaal aangepast voor SL PL and TL lampen normale lichtsterkte and klokken Geen lineaire 800 1200 1600 800 1200 1600 1200 1600 belasting crest factor 3 1 VA 25 C Nominaal vermogen 650 1000 1300 650 1000 1300 1000 1300 W cos 1 0 25 C Nominaal vermogen 600 900 1100 600 900 1100 900 1100 W cos 1 0 40 C Opstart vermogen W 1900 2000 2300 1900 2600 3000 2600 3000 Inschakelgedrag De nominale uitgangsspanning is aanwezig binnen 20mS Rendement Pnom 87 86 84 88 87 86 87 86 efficiency 90 88 87 90 89 87 90 88 Ye Pnom kortsluitstroom 10 12 13 10 12 13 13 15 victron energy N y 25 IN 6 3 Accu lader 12 800 12 1200 12 1600 24 800 24 1200 24 1600 48 1200 48 1600 135 150 170 116 125 140 112 120 Ingangsspanning Vac 200 250 Afschakel spanning lt 180 en gt 270 Vac Frequentie Hz 45 55 of 55 65 Maximale ingangstroom Bij 230 Vac AC uit onbelast A 2 7A 3 9A 5 6A 2 5A 3 8A 6 3A Ingangs zekering TCB 16A 16A 16A 16A 16A 16A 16A 16A 250 Vac Rendement 84 82 81 85 84 83 85 84 Cos q power factor 1 0 Absorption 14 40 28 80 57 6 Laadspanning default Vdc Float laadspanning 13 80 27 60 55 2 default Vdc Uitgang oplaadspanning 8 16 11 32 22 64 Vdc Min max Laad karakteristiek 4 staps autom
103. ieure a longueur 1 25Vrms V rifier la capacit de la batterie et l augmenter si n cessaire La LED Alarm L appareil s est arr t suite a Vois les solutions est allum e fixe la persistance de l une des origines de pr alarme ci dessus possibles ci dessus 24 victron energy A y Probleme Origine Solution Le chargeur ne fonctionne pas La tension et ou la fr quence d alimentation AC sont hors limites Assurer un tension AC comprise entre 185 et 265V et v rifier la fr quence par rapport au r glage La batterie n est pas charg e compl tement Courant de charge mal r gl Regler le courant de charge entre 0 1 et 0 2 x la capacit de la batterie Raccordement s d fectueux V rifier les raccordements Tension Absorption mal r gl e Regler la tension Absorption qui correspond au Typ de batterie Tension Float mal r gl e Regler la tension Float qui correspond au Typ de batterie Capacit batterie trop grande Augmenter si possible le courant de charge Reduire la capacit totale des batteries Fusible DC interne coup Le convertisseur est en panne La batterie est surcharg e Tension Absorption mal r gl e R gler la tension Absorption qui correspond au Typ de batterie Tension Float mal r gl e R gler la tension Float qui correspond au Typ de batterie Batterie en mauvais tat V rifier
104. ilation et assurez vous que les orifices de ventilation ne sont pas obstru s Assurez vous que la puissance souhait e ne soit pas sup rieure a la capacit de l appareil Transport et stockage Assurez vous que les c bles de secteur et de batterie sont d connect s pour le transport et le stockage Aucune responsabilit ne sera accept e pour dommages de transport si l appareil est transport dans un autre emballage que celui d origine Stockez l appareil dans un endroit sec la temp rature de stockage doit tre comprise entre 20C et 60 C Consultez le mode d emploi des batteries en ce qui concerne le transport le stockage la charge et la mise au rebut des batteries 2 AD y victron energy 1 DESCRIPTION 1 1 G n ralit s Multifonctions Multi MultiPlus Compact uniquement Le Multi Compact doit son nom aux nombreuses fonctions qu il assure il rassemble un convertisseur sinusoidal puissant un chargeur sophistiqu a technologie de charge adaptative et un commutateur de transfert ultra rapide En plus de ces fonctions de base le Multi Compact offre de nombreuses caract ristiques avanc es d crites ci dessous qui ouvrent la voie vers des applications nouvelles Alimentation AC ininterrompue Multi Compact MultiPlus Compact seulement En cas de coupure secteur ou de d connexion du quai ou du groupe le convertisseur du Multi Compact reprend automatiquement l alimentation du r seau en sortie Ce transfert
105. imiter naar 0 te draaien PowerAssist Doe meer met Uw aggregaat of walstroom de unieke meehelp functie van de MultiPlus Compact standaard aan Met de MultiPlus Compact kunt U nog een stap verder gaan De MultiPlus Compact werkt parallel met het aggregaat of de walaansluiting en verdubbelt het beschikbare vermogen Tijdelijk te weinig stroom De MultiPlus Compact haalt extra energie uit de accu en helpt mee Nog stroom over De MultiPlus Compact maakt er gebruik van om de accu te laden U stelt de walstroom in met een simpele 0 tot 30 A draaiknop op het Phoenix Multi Control paneel Noot 1 Voor de goede werking van PowerAssist dient minstens 2A netvoeding of een aggregaat met ten minste hetzelfde vermogen als de MultiPlus beschikbaar te zijn Noot 2 Sommige moderne generatoren generen de wisselstroom m b v een statische omvormer Het toerental van deze generatoren wordt meestal teruggeregeld bij geringe belasting Indien met VEConfigure de Dynamic Current Limit functie aangezet wordt zal de MultiPlus een plotselinge belastingsprong opvangen totdat de motor van het aggregaat weer op volle toeren draait 20 Ay y victron energy Extern Alarm Relais en Virtual Switch standaard uitgeschakeld Er is een open collector uitgang beschikbaar waarop en relais aangesloten kan worden tbv alarm en andere signaleringen o a een generator start signaal De maximum belasting is 66V 40mA De functie van de open collector uitgang
106. interior of the product must remain accessible after installation gt Ensure that the AC and DC input cables are fitted with fuses and circuit breakers Try and keep the distance between the product and the battery to a minimum in order to minimize cable voltage losses For safety purposes this product should be installed in a heat resistant environment if it is used with equipment where a substantial amount of power is to be converted You should prevent the presence of e g chemicals synthetic components curtains or other textiles etc in the immediate vicinity victron energy Gul y 3 3 Requirements Philips screwdriver PH2 for removing the front Flat screwdriver 0 6x3 5 for connecting the AC leads Three wire cable 3 4 Connection of Battery cables In order to fully utilize the full capacity of the product batteries with sufficient capacity and battery cables with sufficient cross section should be used See table 24 800 24 1200 12 800 12 1200 12 1600 48 1600 24 1600 48 1200 Recommended cross section mm 1 57 gt 5m 16 25 35 50 70 5 gt 10m 35 50 70 100 140 1 preassembled cable length 1 5 m 24 800 24 1200 12 800 12 1200 12 1600 48 1600 24 1600 48 1200 merommended 40 200 40 400 100 400 150 700 200 700 battery capacity Ah Remark Internal resistance is the important factor when working with low capacity batteries Please consult you
107. ion Time 1 hour Repeated Absorption Interval 7 days Bulk Protection on AC Waveform Check on PowerAssist MultiPlus only on Generator Shore Current 12A System frequency Multi Compact MultiPlus Compact Automatic Inverter Compact 50 Hz AES automatic economy switch off 4 2 Settings which can be changed with the dipswitches Type Battery Type Absorption voltage Float voltage Maximum absorption time 1 Sonnenschein 14 4 V 28 8 V 57 6V 13 8 V 27 6 V 55 2V 4 hours default Dryfit A200 Gel 13 2V 26 4V 52 8V 2 Traction 15 0 V 30 0 V 60 0V 13 8 V 27 6 V 55 4V 6 hours tubular cell 13 2V 26 4V 52 8V 3 Semi Traction 14 4 V 28 8 V 57 6V 14 0 V 28 0 V 56V 5 hours flat plate 13 2V 26 4V 52 8V 4 Low antimony 14 8 V 29 6 V 59 2V 14 0 V 28 0 V 56V 5 hours 13 2V 26 4V 52 8V The optimal absorption voltage for flat plate lead acid batteries is subject to mechanical and chemical properties Batteries with high antimony content can typically be charged with a lower absorption voltage than batteries with low antimony content Please refer to our book Electricity on Board downloadable from our website www victronenergy com for details and suggestions about charging batteries Contact your battery supplier for the correct charge voltages and change with VE configure the voltage settings if required The default
108. kelt Dit is een product uit veiligheidsklasse dat wordt geleverd met een aardklem ter beveiliging De in en of uitgangsklemmen van de wisselstroom moeten zijn voorzien van een ononderbreekbare aarding ter beveiliging Aan de buitenkant van het product bevindt zich een extra aardingspunt Als het aannemelijk is dat de aardbeveiliging is beschadigd moet het product buiten werking worden gesteld en worden beveiligd tegen iedere onopzettelijke inwerkingstelling neem contact op met gekwalificeerd onderhoudspersoneel Zorg ervoor dat de aansluitkabels zijn voorzien van zekeringen en stroomonderbrekers Vervang een beveiligingsonderdeel nooit door een ander Typ Raadpleeg de handleiding voor het juiste onderdeel Controleer voordat u het apparaat inschakelt dat de beschikbare spanningsbron overeenkomt met de configuratie instellingen van het product zoals beschreven in de handleiding Zorg ervoor dat de apparatuur onder de juiste bedrijfsomstandigheden wordt gebruikt Stel het product nooit in bedrijf in de regen of in een stoffige omgeving Zorg ervoor dat er altijd voldoende vrije ruimte rondom het product is voor ventilatie en dat de ventilatie openingen niet ziin geblokkeerd Verzeker u ervan dat de vereiste spanning niet hoger is dan de capaciteit van het product victron energy 1 O y ES Vervoer en opslag Zorg ervoor dat de netspanning en batterijkabels zijn losgekoppeld bij opslag of vervoer van het product Er kan geen
109. l Ap ndice A El aparato puede montarse horizontalmente o verticalmente aunque es preferible el montaje vertical Se refrigera mucho mejor en esta posici n A La parte interior del producto debe quedar accesible tras la instalaci n Aseg rese de que los cables de conexi n est n equipados de fusibles y disyuntores Intente que la distancia entre el producto y la bater a sea la menor posible para minimizar la p rdida de tensi n por los cables Por motivos de seguridad este producto deber instalarse en un entorno resistente al calor si se utiliza con equipos en los que se va a convertir una cantidad de electricidad importante Debe evitarse en su proximidad la presencia de productos qu micos componentes sint ticos cortinas u otros textiles etc 10 victron energy n N y 3 3 Herramientas necesarias Destornillador de estrella PH2 para retirar la parte frontal Destornillador plano 0 6x3 5 para conectar los cables de CA Cable de tres hilos 3 4 Conexi n de los cables de bater a Para utilizar la capacidad del producto en su totalidad deben utilizarse bater as con capacidad suficiente y cables de bater a de secci n adecuada Consulte la tabla siguiente 24 800 24 1200 12 800 12 1200 12 1600 48 1600 24 1600 48 1200 Secci n de cable recomendada mm 157 gt 5m 16 25 35 50 70 5 gt 10m 35 50 70 100 140 1 longitud del cable pre ensamblado 1 5 m 24 800 24 1200 1
110. l aansluiting of het aggregaat Met het Phoenix Multi Control bedieningspaneel kan een maximale wal of aggregaatstroom ingesteld worden De Multi Compact houdt dan rekening met andere stroomverbruikers en gebruikt voor het laden alleen de stroom die nog over is PowerAssist Doe meer met Uw aggregaat of walstroom de unieke meehelp functie van de MultiPlus Compact Met de MultiPlus Compact kunt U nog een stap verder gaan De MultiPlus Compact werkt parallel met het aggregaat of de walaansluiting en verdubbelt het beschikbare vermogen Tijdelijk te weinig stroom De MultiPlus Compact haalt extra energie uit de accu en helpt mee Nog stroom over De MultiPlus Compact maakt er gebruik van om de accu te laden U stelt de walstroom in met een simpele 0 tot 30 A draaiknop op het Phoenix Multi Control Opm 1 Igv parallel bedrijf met een generator mag het vermogen van de generator niet minder zijn dan 75 van het vermogen van de Multi Plus Compact voorbeeld een generator geschikt voor parallel bedrijf met een Multi Plus Compact 12 2000 80 moet een vermogen van minstens 1500 VA hebben Opm 2 De uitgangsspanning van een generator kan sterk vervormd zijn In dat geval moet de AC waveform check uitgezet worden 1 2 Acculader alleen Multi Compact MultiPlus Compact Adaptieve 4 traps laadkarakteristiek bulk absorption float opslag Het microprocessor gestuurde adaptieve accu management systeem kan afgeregeld wor
111. l horizontal wie auch vertikal montiert werden Allerdings sollte es wenn m glich vertikal montiert werden da dies eine optimale K hlung des Ger ts gew hrleistet A Das Innere des Ger ts muss nach der Installation noch gut zug nglich sein Sorgen Sie daf r dass sowohl Netz als auch die Batterie Anschlusskabel ber Sicherungen oder Leistungsschalter abgesichert sind Um den Spannungsverlust ber die Kabel m glichst gering zu halten sollte der Abstand zwischen dem Ger t und der Batterie m glichst kurz sein victron energy 11 N y Aus Sicherheitsgr nden sollte dieses Ger t wie alle elektrischen Verbraucher die eine bestimmte elektrische Leistung umsetzen in einer hitzebest ndigen Umgebung installiert werden So sollten sich zum Beispiel Chemikalien Kunststoffgegenst nde Gardinen oder andere Textilien usw m glichst nicht in der direkten Umgebung befinden 3 3 Erforderliches Werkzeug und Kabel Kreuz Schlitz Schraubenzieher PH 2 zum Abnehmen der Vorderfront Schlitz Schraubenzieher 0 6 x 3 5 zum Anschluss der Wechselspannungskabel Dreiadriges Kabel 3 4 Batteriekabel anschlie en Um die Leistung des Phoenix Multi Compact Multi PlusCompact voll ausn tzen zu k nnen sollten nur Batterien mit ausreichender Kapazit t und Batteriekabel mit dem richtigen Querschnitt verwendet werden Siehe Tabelle 24 800 24 1200 12 800 12 1200 12 1600 48 1600 24 1600 48 1200 Empfohlener Kabelq
112. l y VEILIGHEIDSVOORSCHRIFTEN Algemeen Lees eerst de bij dit product geleverde documentatie zodat u bekend bent met de veiligheidsaanduidingen en aanwijzingen voordat u de apparatuur in gebruik neemt Dit product is ontworpen en getest overeenkomstig internationale normen De apparatuur dient uitsluitend voor de bestemde toepassing te worden gebruikt WAARSCHUWING KANS OP ELEKTRISCHE SCHOKKEN Het product wordt gebruikt in combinatie met een permanente energiebron batterij Zelfs als de apparatuur is uitgeschakeld kan een gevaarlijke elektrische spanning optreden bij de in en of uitgangsklemmen Schakel altijd de wisselstroomvoeding en de batter uit voor het plegen van onderhoud Het product bevat geen interne onderdelen die door de gebruiker kunnen worden onderhouden Haal het paneel aan de voorkant er niet af en stel het product niet in werking als niet alle panelen zijn gemonteerd Al het onderhoud dient door gekwalificeerd personeel te worden uitgevoerd Gebruik het product nooit op plaatsen waar gas of stofexplosies kunnen optreden Raadpleeg de gegevens van de fabrikant van de batterij om u ervan te verzekeren dat het product bestemd is voor gebruik in combinatie met de batterij De veiligheidsvoorschriften van de fabrikant van de batterij dienen altijd te worden opgevolgd WAARSCHUWING Til geen zware lasten zonder hulp Installatie Lees de installatievoorschriften in de bedieningshandleiding voordat u de apparatuur inscha
113. laca de toma de tierra o del casco de un barco Aplicaciones mar timas debido a la posible corrosi n galv nica en general no es aceptable conectar la parte de tierra del pantal n a la placa de toma de tierra O al casco del barco La soluci n m s adecuada y segura es la instalaci n de un transformador de aislamiento El conector G ST18i de conexi n del terminal de entrada y salida de la red se ubica en la parte inferior del Multi Compact ver Ap ndice 1 El cable del pantal n o de red el ctrica deber conectarse al conector G ST18i con un cable de tres hilos Utilice un cable de tres hilos de n cleo flexible y una secci n de entre 1 5 800VA y 2 5 mm 1600VA Procedimiento Conecte los cables CA de la manera siguiente El cable de salida CA puede conectarse directamente al conector macho G ST18i el conector sale tirando de l Los puntos de terminal est n claramente indicados De izquierda a derecha N neutro tierra y L1 fase El cable de entrada AC puede conectarse directamente al conector hembra G ST18i el conector sale tirando de l Los puntos de terminal est n claramente indicados De izquierda a derecha L1 fase tierra y N neutro 12 victron energy n Yy y Introduzca el conector de entrada G ST18i en el conector del terminal cerca de la parte trasera Introduzca el conector de salida G ST18i en el conector del terminal cerca de la parte delanter
114. lectrog ne cette fonction peut tre d sactiv e PowerControl s adapter au limites d un groupe ou du quai usine 30A Pour la prot ger la source d alimentation de l appareil groupe lectrog ne prise de quai le courant de charge disponible pour les batteries est automatiquement r gl de mani re ce que la puissance totale demand e par l appareil soit les puissances additionn es du chargeur et des utilisations en sortie ne d passe pas un niveau d termin Si la consommation AC d passe ce niveau le chargeur est d sactiv et la LED mains on clignote Il est alors possible que le disjoncteur secteur quai saute ou que le g n rateur s arr te en raison de surcharge Le Multi Compact tentera de passer en mode convertisseur La puissance g n rateur courant secteur peut tre r gl e de 1 30A Le r glage sur le tableau de commande distance annule le r glage interne PowerAssist fourniture de puissance suppl mentaire par le convertisseur MultiPlus uniquement usine on PowerAssist est une fonction suppl mentaire qui distingue le MultiPlus Compact du Multi Compact Le MultiPlus travaille en parall le avec la source d alimentation groupe lectrog ne prise de quai et permet de doubler la puissance disponible lorsque la limite fix e voir PowerControl est d pass e le convertisseur du MultiPlus fournit le compl ment partir de la batterie Il est ainsi possible de faire fac
115. lisation le Phoenix Multi Compact charge pendant une heure en tension sur lev e 1V au dessus de la tension d absorption pour une batterie 12V 2V pour une batterie 24V Le courant de charge est alors limit 1 4 de la valeur pr r gl e Les LED bulk et absorption clignotent en alternance 6 AD y victron energy La tension d galisation est sup rieure a ce que peut supporter la plupart des quipements install s Ces derniers doivent tre d branch s avant de d clencher un cycle d galisation Absorption forc e Dans certains cas il peut tre n cessaire de charger la batterie pour une p riode d termin e en mode Absorption En mode Forced Absorption le Phoenix Multi Compact charge avec la tension d absorption normale pendant la pr r gl e La LED absorption s allume seulement sur Phoenix Multi Control Le Phoenix Multi Compact peut tre mis sur ce mode soit par la commande a distance soit par son propre commutateur en face avant La condition est que tous les commutateurs face avant tableau de commande et commande a distance soient sur ON et qu aucun des commutateurs ne soit positionn sur charger only Pour mettre le Phoenix Multi Compact sur ce mode suivez la proc dure d crite ci dessous ATTENTION La Commutation de On a charger only et inversement tel que d crit ici doit se faire rapidement Le commutateur doit tre actionn de fa on ce que la p
116. lling the equipment This is a Safety Class product supplied with a protective grounding terminal Uninterruptible protective grounding must be provided at the AC input and or output terminals Alternatively the grounding point located externally on the product may be used Whenever it is likely that the grounding protection has been damaged the product must be turned off and secured against unintended operation please contact qualified service staff Ensure that the DC and AC input cables are fused and fitted with circuit breakers Never replace a safety component with a different Typ Consult the manual to determine the correct component Before applying power ensure that the available power source matches the configuration settings of the product as described in the manual Ensure that the equipment is used under the correct ambient conditions Never operate the product in a wet or dusty environment Ensure there is adequate free space for ventilation around the product and check that the ventilation vents are not blocked Ensure that the required system voltage does not exceed the product s capacity victron energy 1 Gul y Transport and Storage Ensure that the mains power and battery leads have been disconnected before storing or transporting the product No liability can be accepted for any transport damage if the equipment is shipped in non original packaging Store the product in a dry environment the storage temperatur
117. lon le mode de charge du moment la LED sera allum e permanente bulk absorption ou en clignotant float Si la tension sur AC in est incorrecte elle sera d connect e et le convertisseur est mis en marche Lorsque le commutateur est positionn sur charger only seul le chargeur sera en service si le courant secteur est pr sent Cette tension est galement dirig e sur la sortie AC out CONSEIL Si vous utilisez le Phoenix Multi Compact sur un bateau ou d une mani re g n rale sans surveillance assurez vous que le commutateur soit en position charger only Ceci emp chera la mise en marche du convertisseur en cas de panne secteur ce qui viderait les batteries 2 2 Commande distance Le Phoenix Multi Compact peut tre utilis en option avec une commande distance d nomm e Phoenix Multi Control Cette commande comporte le m me commutateur et reprends les LED de l appareil La fonction chargeur du Phoenix Multi Compact peut tre d sactiv e Ceci peut se faire au moyen du tableau de commande distance en r glant le courant d entr e 0 ou par le menu de param trage avec un PC utiliser l interface MK1 b et le programme VE configure Pour le Phoenix Inverter vous devez utiliser le panneau commande distance Phoenix Inverter Control 2 3 Mode de charge sp cial galisation Certaines batteries n cessitent r guli rement une charge dite d galisation En mode ga
118. ltage ripple on the DC input exceeds 1 25Vrms Check the battery cables and terminals Check the battery capacity increase if necessary The alarm LED flashes intermittantly Pre alarm alt 5 Low battery voltage and excessive load Charge the batteries reduce the load or install batteries with a higher capacity Use shorter and or thicker battery cables The alarm LED is on The inverter did cut out following a pre alarm Check the table for the appropriate course of action 20 victron energy Gul y Problem The charger is not functioning Cause Solution The AC input voltage or frequency is out of range Ensure that the input voltage is between 185 Vac and 265 Vac and that the frequency matches the setting The thermal circuit breaker has tripped Reset the 30 A thermal circuit breaker The battery is not being charged fully Incorrect charging current Set the charging current at between 0 1 and 0 2x battery capacity A defective battery connection Check the battery terminals The absorption voltage has been set to an incorrect value Adjust the absorption voltage to the correct value The float voltage has been set to an incorrect value Adjust the float voltage to the correct value The internal DC fuse is defective Inverter is damaged The battery is The absorption voltage has been Adjust the absorption
119. ltiPlus Compact only An AC voltage connected to the AC in connector will be switched through to the AC out connector if within specifications The inverter will switch off the charger LED will light up and the charger commences charging The charger LED will light up depending on the charger mode on bulk absorption or blinks float If the voltage of the AC in terminal is too high or too low the AC input voltage will switch off and the inverter will be starting When the front switch is switched to charger only only the battery charger of the Phoenix Multi Compact will operate if mains voltage is present In this mode input voltage also is switched through to the AC out terminal NOTE When only the charger function is required ensure that the switch is switched to charger only This prevents the inverter from being switched on if the mains voltage is lost thus preventing your batteries from running flat 2 2 Remote Operation The Phoenix Multi Compact can be operated with the Phoenix Multi control panel The remote control has an on off switch and more indication The charger of the Phoenix Multi Compact can be turned off This can be done by changing the set up configuration by connecting the Phoenix Inverter remote control set the AC input current to 0 or by connecting a computer to the Phoenix Multi Compact use MK 1 with VEConfigure For remote control of the Phoenix Inverter Compact the Phoenix Inverter con
120. luiting tegelijk ook de aard verbinding verbreken In dat geval moet de behuizing verbonden worden met het chassis van het voertuig of met de romp of aardplaat van de boot Op boten is de hierboven beschreven verbinding met de aarde van de walaansluiting i h a niet aan te bevelen v m galavanische corrosie De oplossing hiervoor is plaatsing van een isolatie tranformator victron energy N y Phoenix Multi Compact is voorzien van in en uitgang connector aan de onderkant van de Multi Compact zie appendix 1 De wal of netaansluiting dient met behulp van een drie aderige kabel op de connector te worden aangesloten Maak gebruik van een drie aderige kabel met een soepele kern en een doorsnede van 2 5 mm Procedure Ga voor het aansluiten van de AC kabels als volgt te werk De AC apparatuur kan direct op G ST18i male connector worden aangesloten eerst de connector los trekken Gebruik een drie aderige kabel De aansluitpunten zijn duidelijk gecodeerd Van links naar rechts N nulleider aarde en L1 fase De AC netspanning kan direct worden aangesloten op de GOst18i female connector Gebruik een drie aderige kabel De aansluitpunten zijn duidelijk gecodeerd Van links naar rechts L1 fase aarde N nulleider Druk de netspannings connector G ST18i Female connector in de contra male connector achterste Druk de belastings connector G ST18i male connector in de contra female connector voorst
121. m O Batteriebetrieb charger only Der Inverter ist eingeschaltet und liefert inverter o on Wechselstrom an die Verbraucher charger O z Voralarm Uberlast oder zu niedrige off Batteriespannung oder zu alarm xe hohe Temperatur des Inverters charger only Der Inverter ist ausgeschaltet inverter O on Alarm Batteriespannung zu niedrig charger O TA Temperatur des Inverters zu hoch off Nennleistung berschritten oder alarm Brummspannung an den Batterie charger only klemmen ist zu hoch 8 My y victron energy Ladebetrieb inverter Q on charger e off alarm O charger only inverter on charger 8 off alarm O charger only inverter O on charger J off alarm O charger only inverter O on charger xe off alarm O charger only Die Netzspannung ist durchgeschaltet und das Ladeteil liefert Konstantstrom bulk phase oder Konstantspannung absorption phase Die Netzspannung ist durchgeschaltet und das Ladeteil ist ausgeschaltet Der Lader kann die Gasungsspannung der Batterie nicht innerhalb der vorgegebenen Konstantstromzeit erreichen Die Netzspannung ist durchgeschaltet und das Ladeteil liefert Konstantstrom bulk phase oder Konstantspannung absorption phase Die Netzspannung ist durchgeschaltet und das Ladeteil l dt mit Ladeerhaltungsspannung float Modus victron energy A y Fernbedienung Phoenix Multi Control optional Fernbedienungspanel inverter on Fe mains
122. m ZX charger only inverter O n charger O off alarm O charger only La tension r seau est transf r e et le chargeur est arr t Le chargeur ne parvient pas atteindre la tension de fin de charge Mode protection La tension r seau est transf r e et le chargeur fonctionne en mode bulk ou absorption La tension r seau est transf r e et le chargeur fonctionne en mode float Le convertisseur est en marche et alimente les utilisations Pr alarme Surcharge Temp rature chargeur Le convertisseur chargeur est arr t Les utilisations ne sont pas aliment es victron energy Gul y Indications du tableau Phoenix Multi Control option PowerControl inverter on Fe mains on overload O bulk low battery O absorption temperature O float on charger only off Note When the LED s overload and low battery are on simultaneously the Multi Plus or Inverter Compact has switched off due to excessive DC ripple voltage 10 AD y victron energy 3 INSTALLATION AN Le Phoenix Multi Compact doit tre install par un technicien qualifi 3 1 Contenu de l emballage L emballage du Phoenix Multi Compact contient les articles suivants Phoenix Multi ou MultiPlus Compact Manuel d utilisation et d installation Sachet de mat riel de connexion comprenant Plaque de fixation Vis 5 Sonde de temp rature Autocollant d avertissement Courant de charge 3 2 Empl
123. m abgeben kann Der zweite Ausgang ist zum Laden der Starterbatterie vorgesehen Folglich ist er auf 4 A begrenzt und hat eine etwas niedrigere Ausgangsspannung zur Ladeerhaltung der in der Regel vollen Starterbatterie H here Batterie Lebensdauer durch Temperaturkompensation Zu jedem Phoenix Multi Compact MultiPlus Compact wird ein Temperatursensor mitgeliefert Der Temperatursensor sorgt f r eine aonehmende Ladespannung bei steigender Batterietemperatur Besonders wichtig ist dies bei Gel Batterien oder wenn st ndig hohe Temperaturschwankungen erwartet werden Weitere Informationen ber Batterien und ihre Ladung In unserer Brosch re Strom an Bord erfahren Sie mehr ber Batterien und ihre Ladung Sie erhalten die Brosch re kostenlos bei Victron Energy oder unter www victronenergy com im Internet N here Einzelheiten ber die adaptive Ladekennlinie finden Sie unter Technical Information auf unserer Website 4 AD y victron energy 1 3 bersicht Artikelnummern f r Zubeh r Phoenix Multi Control Phoenix Inverter Control Temperaturf hler TI UTP Verl ngerungskabel 5 m UTP Verl ngerungskabel10 m UTP Verl ngerungskabel15 m PC Interface MK1 b USB Adapter VEConfigure Software REC020002000 RECO30001000 ASS000001000 ASS030065000 ASS030065010 ASS030065020 ASS0301B0000 ASS030200000 Download von unserer Webseite victron ener A y s 2 Betriebsweisen 2 1 On off charger only Schalter Nur Phoenix Mul
124. menge angepasste Konstantspannungszeit Bei geringer Batterieentladung wird eine kurze Konstantspannungsphase gew hlt um eine berladung und berm ige Gasentwicklung zu vermeiden Nach einer Tiefentladung wird die Konstantspannungsphase automatisch verl ngert um die Batterie vollst ndig zu laden Verhindern von Sch den durch berm ige Gasentwicklung Batterieschonmodus Um die Ladezeit zu verk rzen wird ein m glichst hoher Ladestrom bis zum Erreichen der Gasungsspannung angestrebt Damit aber eine berm ige Gasentwicklung gegen Ende der Konstantstromphase vermieden wird begrenzt der Multi Compact Multi Plus Compact die Geschwindigkeit des Spannungsanstiegs Weniger Wartung und Alterung im Ruhezustand der Batterie der Lager Modus Der Lager Modus wird immer dann aktiviert wenn innerhalb von 24 Stunden keine Entladung erfolgt ist Die Ladeerhaltungsspannung wird dann auf 2 2 V Zelle 13 2 V f r eine 12 V Batterie gesenkt um die Gasentwicklung zu minimieren und damit eine Korrosion an den positiven Platten zu verhindern Einmal pro Woche wird die Spannung auf den Level der Gasungsspannung erh ht Dadurch wird eine Art Ausgleichsladung erzielt die die Elektrolytschichtung und die Sulfatierung die beiden Hauptgr nde f r vorzeitigen Batterieausfall verhindert Zwei Ausg nge zum Laden von zwei Batterieb nken Der Phoenix Multi Compact MultiPlus Compact verf gt ber 2 Ausg nge von denen einer den vollen Ausgangsstro
125. mesure directe de la tension aux bornes de la batterie permet au chargeur de compenser les pertes de tension dans le c blage principal Pour tout savoir sur les batteries Notre livre L Electricit a Bord traite en d tail des diff rents Typs de batterie et des techniques de charge Distribu gratuitement et t l chargeable sur notre site www victronenergy com Pour plus de d tails sur la technologie de charge adaptative voir la rubrique infos techniques sur notre site 1 3 Liste et r f rences des accessoires disponibles en option Tableau Phoenix Multi control REC020002000 Tableau Phoenix Inverter control REC030001000 Sonde de temp rature Tl ASS000001000 Cordon UTP Patch lead 5 m ASS030065000 Cordon UTP Patch lead 10 m ASS030065010 Cordon UTP Patch lead 15 m ASS030065020 Interface pour PC MK1 b ASS0301B0000 Adaptateur USB ASS030200000 VEConfigure programme de param trage T l chargement victron energy 5 Gul y 2 UTILISATION 2 1 Commutateur On Off charger only Lorsque le commutateur est positionn sur On l appareil fonctionne int gralement Le convertisseur est mis en marche et la LED inverter on s allume Multi MultiPlus Compact uniquement Si l entr e AC in est mise sous tension l appareil redirige cette tension sur la sortie AC out si elle est l int rieur des limites param tr es Le convertisseur est arr t la LED charger s allume et le chargeur se met en marche Se
126. minimum wanneer de accu langere tijd niet wordt gebruikt Na een ingestelde tijd standaard 7 dagen zal de lader overgaan in de Repeated Absorption mode voor een ingestelde tijd standaard 4 kwartieren 18 De y victron energy 4 4 Instelling lader alleen Multi Compact MultiPlus Compact De nu volgende instellingen kunnen alleen gewijzigd worden met VEConfigure software Lader aan uit standaard aan z De lader van de Phoenix Multi Compact kan desgewenst ook uitgeschakeld worden Fr 4 4 1 De 3 voorgeprogrameerde laadcurves De Fixed laadkarakteristiek biedt de absorption spanning voor een bepaalde vast instelbare tijd aan Na de absorptionfase wordt een bepaalde wederom vast instelbare tijd de floatspanning aangeboden om daarna periodiek gedurende een meestal kortere tijd weer de absorptionspanning aan te bieden De Adaptieve laadkarakteristiek biedt de absorptionspanning aan gedurende een tijd afhankelijk van de lading die tijdens bulk is geleverd Daarna volgt een floatfase van 24 uur waarna naar 13 26V gereduceerd float wordt teruggeschakeld Net als bij de Fixed laadkarakteristiek wordt ook hier periodiek een absorptionfase aangehouden Adaptieve laadkarakteristiek met BatterySafe mode standaard instelling Indien om de laadtijd te verkorten gekozen wordt voor een hoge laadstroom en ook een verhoogde laadspanning dan zal de Phoenix Multi Compact MultiPlus Compact nadat de gasspanning bereikt is de stijgsnelheid
127. n cargador de bater as muy potente Por lo tanto usar mucha corriente del generador o de la red del pantal n casi 5 A por Multi Compact a 230 VCA En el Phoenix Multi Control PMV puede establecerse una corriente m xima proveniente del generador o del pantal n El Multi Compact tendr en cuenta las dem s cargas CA y utilizar la corriente sobrante para la carga evitando as sobrecargar el generador o la red del pantal n PowerAssist Aumento de la capacidad el ctrica del pantal n o del generador La caracter stica que distingue al Phoenix MultiPlus Compact del MultiPlus Compact normal es la funci n PowerAssist Esta funci n lleva el principio de PowerControl a otra dimensi n permitiendo que el MultiPlus Compact complemente la capacidad de la fuente alternativa Cuando se requiera un pico de potencia durante un corto espacio de tiempo como pasa a menudo es posible reducir la potencia de generador necesaria o por el contrario aumentarla para compensar la conexi n del pantal n casi siempre limitada Cuando se reduce la carga la potencia sobrante se utiliza para recargar la bater a Nota 1 La capacidad del generador deber a ser de 75 o m s en comparaci n con la capacidad VA del MultiPlus Compact por ejemplo para funcionar en paralelo con un Multi Compact 12 1200 50 ser necesario un generador de al menos 900 VA Nota 2 La curva de corriente de salida de un generador puede verse seriamente distorsionada En este
128. n de absorci n elevada Multi Compact MultiPlus Compact evitar que se produzcan da os por exceso de burbujeo limitando autom ticamente el ritmo de incremento de tensi n una vez se haya alcanzado la tensi n de burbujeo El modo BatterySafe forma parte del tiempo de absorci n calculado Modo absorption Un periodo de tensi n constante para cargar completamente la bater a El tiempo de absorption es igual a 20 veces el tiempo bulk o al tiempo de absorci n m ximo cualquiera que se d en primer lugar Modo float La tensi n de flotaci n se aplica para mantener la bater a completamente cargada y para protegerla contra la autodescarga Flotaci n reducida Tras un d a de carga de flotaci n se aplica una carga de flotaci n reducida Esto es 13 2V resp 26 4V para cargadores de 12V y 24V Esto mantendr la p rdida de agua al m nimo cuando la bater a se almacene para la temporada de invierno Tras un periodo de tiempo que puede ajustarse por defecto 7 d as el cargador entrar en modo Repeated Absorption absorci n repetida durante un periodo de tiempo que se puede ajustar por defecto 1 hora victron ener N y Wi 4 4 Ajustes del cargador s lo Multi Compact MultiPlus Compact 4 4 1 Curvas de carga preprogramadas s lo puede cambiarse con VEConfigure Le rogamos consulte nuestro libro Electricidad a Bordo que puede descargarse desde nuestro sitio web www victronenergy c
129. nd improve its products as it sees fit This publication describes the state of this product at the time of its publication and may not reflect the product at all times in the future SAFETY RULES General Please familiarize yourself with the safety features and instructions by first reading the documentation supplied with this product before using the equipment This product has been designed and tested in accordance with international standards The equipment must be used exclusively for the purpose for which it was designed WARNING ELECTRIC SHOCK HAZARD The product is used in conjunction with a permanent energy source battery Input and or output terminals may still be dangerously energized even when the equipment is switched off Always switch off the AC supply and the battery before carrying out maintenance or servicing the product The product has no internal user serviceable components Do not remove the front plate or operate the product if any panels have been removed All servicing must be undertaken by qualified personnel Never use the product where there is a risk of gas or dust explosions Consult the battery manufacturer s information to ascertain that the product is intended for use in conjunction with the battery Always comply with the battery manufacturer s safety instructions WARNING Do not lift heavy loads without assistance Installation Read the installation instructions in the installation manual before insta
130. nier 2 x 1 5mm auxiliaire Raecordements Marche arr t distance sur circuit imprim bornier 3 x 1mm externes M A sonde 7 Sonde temp rature batterie sur circuit imprim bornier 2 x 1mm distance Alarme transistor a collecteur ouvert 66V 40mA connecteur pour 2 fils 0 5 mm Port s rie UTP 8 p les Pour tableau de commande distance Pour interface MK 1 et software VEConfigure victron energy 29 Gul y SICHERHEITSVORSCHRIFTEN Allgemeines Lesen Sie erst die mitgelieferte Beschreibung sorgf ltig durch bevor Sie das Ger t in Betrieb nehmen und machen Sie sich mit den Sicherheitsvorschriften vertraut Dieses Produkt wurde in Ubereinstimmung mit internationalen Normen entworfen und getestet Das Ger t darf ausschlie lich f r den vorgesehenen Verwendungszweck benutzt werden VORSICHT ES BESTEHT DIE GEFAHR EINES ELEKTRISCHEN SCHLAGS Das Ger t wird in Verbindung mit einer st ndigen Energiequelle Batterie betrieben Dadurch k nnen die Ein und oder Ausgangsanschl sse gef hrliche elektrische E Spannungen f hren auch wenn das Ger t ausgeschaltet ist Trennen Sie das Ger t immer erst vom Netz und von der Batterie wenn Sie an ihm arbeiten Im Ger t gibt es keine Teile die der Verbraucher selbst warten k nnte Nehmen Sie das Paneel an der Vorderseite nicht ab und schalten Sie das Ger t nicht ein wenn nicht alle Paneele montiert sind Arbeiten daran gleich welcher Art sollten ausschlie
131. om para obtener m s datos y consejos sobre cargas de bater as El Phoenix Multi Compact MultiPlus Compact tiene 3 curvas de carga preprogramadas Curva de carga fija de 3 etapas El periodo de absorci n tiene una duraci n preestablecida fija Tras el modo de absorci n el cargador cambia a flotaci n Para refrescar la bater a el cargador vuelva a cambiar peri dicamente a absorci n Curva de carga variable El periodo de absorci n depende de la duraci n del periodo de carga inicial ver p rrafo 4 3 Esto viene seguido de una fase de flotaci n que dura 24 horas tras la cual la tensi n se reduce en un adicional 0 8 V resp 1 6 V para 12 V resp bater as de 24 V flotaci n reducida Al igual que con la curva de carga fija el cargador regresar peri dicamente a la carga de absorci n Curva de carga variable con el modo BatterySafe por defecto Si para cargar una bater a r pidamente se ha elegido una combinaci n de alta corriente de carga con una tensi n de absorci n alta el cargador Phoenix evitar que se produzcan da os por exceso de burbujeo limitando autom ticamente el ritmo de incremento de tensi n una vez se haya alcanzado la tensi n de burbujeo 4 4 2 Otros ajustes Tiempo de absorci n por defecto 4 horas El ajuste de la absorci n define el periodo fijo de absorci n en el caso de la curva de carga fija y el tiempo m ximo de absorci n en el caso de la curva de carga variable El tiempo
132. on overload O bulk low battery O absorption temperature O float on O charger only off Note When the LED s overload and low battery are on simultaneously the Multi Plus or Inverter Compact has switched off due to excessive DC ripple voltage 10 My y victron energy 3 MONTAGE Der Phoenix Multi Compact Multi Plus Compact darf nur von einer qualifizierten Elektrofachkraft installiert werden 3 1 Verpackungsinhalt Die Verpackung des Phoenix Multi Compact Multi Plus Compact enth lt folgende Einzelteile Phoenix Multi Compact Phoenix Multi Plus Compact oder Inverter Compact Bedienungsanleitung Montageanleitung T te mit Montagematerial Befestigungsplatte Schrauben 5 Temperaturf hler Aufkleber mit Warnhinweis f r den Ladestrom 3 2 Aufstellungsort Der Phoenix Multi Compact MultiPlus Compact muss in einem trockenen gut ventilierten Raum installiert werden m glichst nahe an den Batterien Zur besseren K hlung muss um das Ger t 10 cm Luft gelassen werden Eine zu hohe Raumtemperatur kann folgende Auswirkungen haben k rzere Lebensdauer geringerer Ladestrom geringere Spitzenleistung oder komplettes Abschalten des Inverters Montieren Sie das Ger t niemals direkt ber den Batterien Der Phoenix Multi Compact MultiPlus Compact ist auch zur Wandmontage geeignet Zum Befestigen des Ger ts sind an der R ckseite des Geh uses zwei L cher angebracht Siehe Anhang A Das Ger t kann sowoh
133. onible y descargable gratuitamente desde www victronenergy com Para m s informaci n sobre la carga variable le rogamos vaya a la secci n sobre informaci n t cnica de nuestro sitio web 1 3 Listado de n meros de referencia de accesorios Panel Phoenix Multi control REC020002000 Panel Phoenix Inverter control REC030001000 Sensor de temperatura TI ASS000001000 Cable de conexi n de 5 m ASS030065000 Cable de conexi n de 10 m ASS030065010 Cable de conexi n de 15 m ASS030065020 Interfaz para PC MK1 b ASS0301B0000 Adaptador USB ASS030200000 Programa VEConfigure Puede descargarse desde nuestro sitio web 4 victron energy My y 2 FUNCIONAMIENTO 2 1 Conmutador On Off Cargador s lo Al poner el conmutador frontal en on el producto es totalmente operativo El inversor se pone en marcha y el LED inverter on se enciende S lo en Multi Compact MultiPlus Compact Si la entrada AC in tiene tensi n esta ser redirigida a trav s del conector AC out si est dentro de las especificaciones El inversor se apagar el LED charger se encender y el cargador empezar a cargar El LED charger cargador se encender seg n el modo de carga fijo inicial absorci n o parpadeo flotaci n Si la tension del terminal AC in es demasiado alta o demasiado baja la tensi n de entrada CA se interrumpir y el inversor arrancar Cuando el conmutador frontal se pone en charger only s
134. open collector output can be programmed with VEConfigure 4 6 Maintenance The Phoenix Multi Compact does not require specific maintenance Annual checking of all connections and eventually removal of dust suffices Protect the product from humidity and oil fumes and keep it clean victron ener Gul y gy 19 5 TROUBLE SHOOTING TABLE Proceed as follows for quick detection of common faults DC loads must be disconnected from the batteries and the AC loads must be disconnected from the inverter before the inverter and or battery charger is tested Consult your Victron Energy dealer if the fault cannot be resolved Problem Cause Solution The inverter fails to operate when The battery voltage is too high or too low Ensure that the battery voltage is within the correct value switched on The inverter fails Processor in no function mode Disconnect mains voltage to operate Switch Front switch off wait 4 seconds Switch front switch on The alarm LED flashes Pre alarm alt 1 The DC input voltage is low Charge the battery or check the battery connections The alarm LED flashes Pre alarm alt 2 The ambient temperature is too high Place the inverter in a cool and well ventilated room or reduce the load The alarm LED flashes Pre alarm alt 3 The load on the inverter is higher than the nominal load Reduce the load The alarm LED flashes Pre alarm alt 4 Vo
135. or 1 mm draden Externe Remote switch connector voor 3 draden 1mmf connection eg remote Batterij temperatuur sensor connector for 2 wire 1mm Alarm transistor open collector 33V 40mA connector voor 2 draden 0 5 mm Seri le interface Voor Phoenix Remote Control Voor MK met VE configure software 27 victron energy O y IN CONSIGNES DE SECURITE G n ralit s Lisez toute la documentation fournie avec l appareil afin de vous familiariser avec les r gles de s curit avant toute utilisation Ce produit a t concu et test selon les normes internationales Cet appareil ne doit tre utilis que pour l application a laquelle il est destin ATTENTION DANGER DE CHOC ELECTRIQUE L appareil est utilis conjointement avec une source d nergie permanente batterie M me lorsque l appareil est hors tension une tension dangereuse peut tre pr sente sur les bornes d entr e et de sortie Toujours d brancher l alimentation de courant alternatif et la batterie avant toute manipulation d entretien Cet appareil ne comprend aucun l ment interne pouvant tre r par ou entretenu par l utilisateur Ne jamais retirer le panneau frontal et ne jamais mettre l appareil en service si tous les panneaux ne sont pas mont s Tout entretien doit tre effectu par un personnel qualifie Ne jamais utiliser l appareil l o des explosions de gaz ou de poussi re peuvent se produire Consulter les indications
136. osition interm diaire soit en quelque sorte omise Si le commutateur reste un tant soit peu en position OFF vous risquez de mettre l appareil hors fonction Dans ce cas vous devez recommencer l tape 1 Cette op ration au moyen du commutateur en face avant demande un peu d exercice L utilisation de la commande distance permet de meilleurs r sultats 1 Assurez vous que tous les commutateurs face avant tableau de commande et commande a distance selon le cas soient positionn s sur ON 2 Assurez vous que le Phoenix Multi Compact charge L entr e AC doit donc tre sous tension assurez vous que la LED mains on et une des LED bulk absorption ou float sont allum es sur le tableau de contr le 3 Mettez le commutateur successivement sur charger only On et charger only Attention La commutation elle m me doit tre rapide mais l intervalle entre les deux commutations doit tre d une demie seconde 2 secondes 4 Les LED bulk absorption et float clignotent alors 5 fois Ensuite les LED bulk absorption et float s allument l une apr s l autre pendant 2 secondes e Sile commutateur est mis sur on alors que la LED bulk est allum e le chargeur passe en mode Egalisation e _ Si le commutateur est mis sur on alors que la LED absorption est allum e le chargeur est mis en mode Absorption forc e vict
137. ound relay Ground in closed when backfeed and output Backfeed is open connected Safety relay to chassis Bidirectional converter Kass to disconnect Ground relay permanently L cut Eha sis o yellow green wire input output ground terminals should be permanently connected to ground M victron energy W Appendix 2 Installation information NL F D ES A Scheidingstransformator Transfo d solement Trenntrafo Transformador de aanbevolen op recommand sur aislamiento schepen bateaux recomendado en barcos B Altijd een Toujours installer un Immer Fehlstrom FI Instalar siempre un scheidingstrafo disjoncteur diffentiel schutzschalter einbauen disyuntor diferencial installeren C Thermische Fusible d entree Thermischer berstrom Fusible de entrada ingangszekering thermique schutzschalter t rmico D Ingang Entr e Netzeingang Entrada E Uitgang Sortie Verbracherausgang Salida F Aardverbinding naar Liaison la terre du Verbindung Conexi n a tierra de la behuizing boitier Landstromerde carcasa geh use Veiligheidsrelais AC Relais de s curit R ckstromschutzrelais Rel de segurida ingang antie retour entr e H Aardrelais sluit Relais de mise la terre Erdungsrelais Kontakt Rel de puesta a tierra wanneer G opent ferm quand G est geschlossen wenn cerrado cuando G est ouvert Kontakt des R ckstrom abierto schutzrelais f
138. puaddy APPENDIX 1 Overview connections J Mains Inverter K Main Battery F Main Battery Female Male GST 18 GST 18 connector connector M victron energy Y Appendix 1 overview connections NL F D ES A Dipswitch schakelaar Commutateur Dipswitch Dipswitch Schalter Conmutador Dipswitch B Ingangs zekering Disjoncteur entr e Eingangssicherung Disyuntor de entrada C Communicatiepoort Port de communication Kommunikationsanschlu Puerto de ss comunicaciones D Temperatuursensor Sonde de temperature Temperaturf hler Sensor de temperatura E Alarm contact Contact d alarme Alarmkontakt Contacto de alarma F Accu Minus N gatif batterie Batterie Minus Negativo de la bateria G Startaccu Plus Positif batterie auxiliaire Starterbatterie Plus N de la bateria auxiliar H Afstandsbediening Commande distance Fernbedienung Control remoto Net IN Alimentation secteur Netz Ein Alimentaci n de red J Net omvormer UIT Sortie secteur conv pie Wechselrichter Salida red conversor K Accu Plus Positif batterie Batterie Plus Positivo de la bateria victron ener A y 2 xipuaddy A Isolation transformer Phoenix Multi Appendix 2 Installation information recommended on boats Compact chassis B Always install a GFCI ground fault circuit interrupter C ac input shore supply thermal circuit breaker Gr
139. r supplier or the relevant sections of our book electricity on board downloadable from our website Procedure Proceed as follows to connect the battery cables A Connect the battery cables the red on the left and the black on the right to the battery see Anhang A Reverse polarity connection to and to will cause damage to the Phoenix Multi Compact Safety fuse inside the Multi Compact can be damaged Secure the nuts tightly in order to reduce the contact resistance as much as possible Use an insulated box spanner in order to avoid shorting the battery Avoid shorting the battery cables 10 AD y victron energy 3 5 Connection of the AC cabling Uninterruptible protective grounding must be provided at the AC input and or output terminals and or chassis grounding point located externally on the product See the following instructions This is a Safety Class product supplied with a protective grounding terminal El a The Phoenix Inverter Compact has a free floating AC output The grounding point located externally on the product must be used to ground the chassis The neutral output wire must be connected to ground to ensure proper functioning of a GFCI Ground Fault Circuit Interrupter b Phoenix Multi MultiPlus Compact the output neutral wire will automatically be bonded to the chassis with the output ground relay see appendix 2 when no external AC source is available backfeed safety r
140. r zul ssigen Betriebsbedingungen genutzt wird Betreiben Sie das Ger t niemals im Regen in feuchter oder staubiger Umgebung Sorgen Sie daf r dass Luft frei um das Ger t zirkulieren kann und dass die Ventilations ffnungen frei gehalten werden victron energy 1 N y Stellen Sie sicher dass die geforderte Systemspannung der des Ger ts entspricht Transport und Lagerung Sorgen Sie daf r dass das Ger t bei der Lagerung oder beim Transport vom Netz und der Batterie getrennt ist Es wird keine Haftung f r Transportsch den bernommen wenn das Ger t nicht in der Originalverpackung transportiert wird Lagern Sie das Ger t an einem trockenen Ort die Lagertemperatur muss zwischen 20 C und 60 C liegen Informieren Sie sich in der Bedienungsanleitung des Batterieherstellers ber den Transport die Lagerung das Aufladen Wiederaufladen und das Entsorgen der Batterie 2 AM y victron energy 1 BESCHREIBUNG 1 1 Allgemeines Phoenix Multi Compact Multi funktional nur Phoenix Multi Compact MultiPlus Compact Der Multi Compact hat seinen Namen aufgrund der vielen Funktionen die er erf llen kann Er ist ein leistungsf higer Wechselrichter mit reiner Sinuswelle ein fortschrittlicher Batterielader der die adaptive Ladetechnologie nutzt und ein Hochgeschwindigkeits Wechselspannungs Transferschalter in einem einzigen kompakten Geh use Aber neben diesen grunds tzlichen Funktionen hat der Phoenix Multi Compact Multi
141. rante este ciclo los LED bulk y absorption parpadear n de manera alterna s lo Phoenix Multi Control La tensi n de igualaci n es superior a la que pueden soportar la mayoria de los equipos instalados que consumen CC Estos ltimos deber n desconectarse al realizar una carga de igualaci n victron energy 5 O y Absorci n forzada En ciertos casos podr a ser necesario cargar la bater a en modo de absorci n durante un periodo de tiempo determinado En el modo Forced Absorption el Phoenix Multi Compact cargar a la tensi n de absorci n normal durante el periodo de absorci n m ximo preestablecido El LED absorption se encender s lo en el Phoenix Multi Control El Phoenix Multi Compact puede ponerse en cualquiera de estos modos desde el control remoto as como desde el panel frontal Es necesario que todos los conmutadores frontal remoto control remoto est n en on y que ninguno de estos est en la posici n charger only Proceda de la manera siguiente para cambiar el Phoenix Multi Compact ya sea al modo ecualizador o al modo absorci n forzada NOTA cambie el conmutador de on a charger only y otra vez a on r pidamente El conmutador debe accionarse de forma que se omita la posici n intermedia Si el conmutador pertinente permanece en posici n off aunque sea por muy poco tiempo corre el riesgo de que apague la aplicaci n En este caso deber
142. rger only inverter O Sh charger Xe off alarm O charger only inverter on charger J A off alarm charger only inverter O oh charger O i off alarm O charger only inverter O on charger Xe El off alarm O charger only inverter O on charger LE i off alarm ZX charger only 8 De netspanning is doorgeschakeld en de lader laadt in de bulk mode en of absorption mode De netspanning is doorgeschakeld en de lader laadt in de float mode De netspanning is doorgeschakeld en de en de lader is uitgeschakeld De lader kan niet in een bepaalde tijd zijn eindwaarde accu spanning bereiken Lader staat in bulk protection Mode De netspanning is doorgeschakeld en de lader staat in bulk of absorption mode De netspanning is doorgeschakeld en de lader staat in float mode De netspanning is doorgeschakeld en er is een vooralarm overbelast of de lader is warm victron energy N y Phoenix Remote Control indicatie optioneel PowerControl inverter on ce overload O low battery O temperature O on off mains on bulk absorption float charger only Opm Wanneer de LED s overload en low battery tegelijk branden is apparaat uitgeschakeld tgv te hoge rimpel op de gelijkspanning victron ener A y Ss Cal 3 INSTALLATIE Dit product mag alleen door een gekwalificeerde elektrotechnicus worden geinstalleerd 3 1 Inhoud van de doos De doos van de Phoenix Multi Compact
143. rida y el cargador funciona en modo bulk o absorption La tension de la red est transferida y el cargador funciona en modo float victron energy O y Phoenix Panel de control remoto Phoenix opcional PowerControl inverter on X mains on overload O bulk low battery O absorption temperature O float on O charger only off Nota Cuando los LED overload y low batery est n encendidos simult neamente el Multi Plus o el Inverter Compact se ha apagado debido a un exceso de ondulaci n de tensi n CC victron ener A y W 3 INSTALACI N AN El producto deber ser instalado por un electricista cualificado 3 1 Contenido de la caja Phoenix Multi Compact MultiPlus Compact o Inverter Compact Manual de usuario manual de instalaci n Bolsa con piezas de conexi n es decir Placa de montaje Tornillos 5 Sensor de temperatura Pegatina de aviso Corriente de carga 3 2 Ubicaci n El producto debe instalarse en una zona seca y bien ventilada tan cerca como sea posible de las bater as Debe dejarse un espacio de al menos 10 cm alrededor del aparato para refrigeraci n Una temperatura ambiente demasiado alta tendr como resultado Una menor vida til Una menor corriente de carga Una menor capacidad de pico o que se apague el inversor Nunca coloque el aparato directamente sobre las bater as El producto est pensado para montarse en la pared Consulte e
144. rn dass die LED Anzeige charger leuchtet nur bei Phoenix Remote Control die LED Anzeige mains und entweder bulk absorption oder float Anzeigen m ssen leuchten 3 Stellen Sie den Schalter nacheinander auf charger only on und wieder charger only Achtung Sie m ssen schnell umschalten und die Zeit zwischen dem Umschalten muss zwischen 1 2 Sekunde und 2 Sekunden liegen 4 Die LED Anzeigen gr n gelb und rot in der Frontabdeckung blinken nun f nf mal auf wenn ein Phoenix Multi Control Panel vorhanden ist blinken bulk absorption und float LEDs f nf mal Danach leuchten die LED Anzeigen gr n gelb und rot in der Frontabdeckung nacheinander jeweils 2 Sekunden lang e Wenn der Schalter auf on gestellt wird w hrend die gr ne LED Anzeige leuchtet wird das Ladeteil in den Equalize Modus geschaltet e Wenn der Schalter auf on gestellt wird w hrend die gelbe LED Anzeige leuchtet wird das Ladeteil in den Forced Absorption Modus geschaltet victron energy 7 N y Sollte der Schalter nach diesen Schritten nicht in der gew nschten Position stehen schalten Sie einfach weiter An der nun eingestellten Ladekennlinie wird sich dadurch nichts ndern 2 4 LED Anzeigen und ihre Bedeutung O LED aus X LED blinkt O LED leuchtet Inverter Wechselrichter Betrieb invertor e on Der Inverter ist eingeschaltet und liefert charger O ott Wechselstrom an die Verbraucher alar
145. ron energy 7 Gul y Si apr s ces tapes le commutateur n est pas dans la position souhait e il peut encore tre rapidement bascul Ceci ne modifiera pas le mode de charge 2 4 Indications et signification des voyants LED O LED teinte X LED clignotante O LED allum e Convertisseur inverter J on charger O off alarm O charger only inverter O on charger O off alarm Fe charger only inverter O on charger O off alarm O charger only inverter O on charger O off alarm O charger only inverter O on charger xe off alarm O charger only 8 Le convertisseur est en marche et alimente les utilisations Fonctionnement sur batterie Le convertisseur est en marche et alimente les utilisations Pr alarme Surcharge Tension batterie basse Temp rature convertisseur Le convertisseur est arr t Alarme Tension batterie trop basse Temp rature convertisseur Surcharge Ondulation r siduelle sur batterie Trop forte mauvais raccordement La tension r seau est transf r e et le chargeur fonctionne en mode bulk ou absorption La tension r seau est transf r e et le chargeur fonctionne en mode float victron energy O y inverter on charger 2 off alarm Oo charger only inverter O n charger J off alarm O charger only inverter O bn charger xe off alarm O charger only inverter O on charger ZX off alar
146. roominstelling De interne DC zekering is kapot Omvormer is defect De accu wordt overladen De absorptionspanning is op een verkeerde waarde ingesteld Regel de absorptionspanning af op een goede waarde De floatspanning is op een verkeerde waarde ingesteld Regel de floatspanning af op een goede waarde Een slechte accu Vervang de accu Een te kleine accu Reduceer de laadstroom of gebruik een accu met een hogere capaciteit De accu staat te warm Sluit een temperatuursensor aan De laadstroom zakt terug naar 0 zodra de absrptie fase ingaat De accu is oververhit gt 50 C Plaats de accu in een koelere ruimte Verlaag de laadstroom Kijk of een van de accucellen een interne sluitng heeft De accu temperatuur sensor is stuk Maak het stekkertje van de temperatuur sensor in de Multi los Reset de Multi door deze uit te schakelen en na minstens 4 seconden wachten weer aan te zetten Indien de laad functie nu weer goed is moet de temperatuur sensor vervangen worden victron energy O y 23 ES 6 TECHNISCHE SPECIFICATIES 6 1 ALGEMEEN Ventilatie Geforceerde convectie intern Temperatuurbereik Tiidens werking 20 50 C Bij opslag 25 60 C Beveiligd Uitgang kortsluitvast Overbelasting Accuspanning te hoog Accuspanning te laag 230V netspanning op de uitgang van de omvormer
147. s DS8 zuerst von off nach on und dann wieder zur ck nach off stellen Eingangswechselstrom Begrenzung ES DS 1 DS 1 DS 2 on DS 2 on ps3 DS 3 SH ps4 DS 4 Gest DS 5 Ds 6 D DS 6 DS 7 DS 7 sa DS 8 DS 8 DS7 off max 30A Sie k nnen die Einstellungen DS7 speichern indem DS7 on max 6 A Sie die Position des Schalters DS8 zuerst von off nach on und dann wieder zur ck nach off stellen 18 victron ener A y 4 3 Die adaptive Ladekurve Charge current 120 100 80 Amps 60 40 20 0 Volts A Charge voltage 16 64 32 Batterie 15 i Schonmodus 14 4 3 20x Konstantstrom L Stunden oder 13 Max 60 30 12 11 10 56 28 Time Konstantstrom Konstant 1Tag 7 Tage 7 Tage Ladeer reduzierte reduzierte e 1Stunde 4 Phasen Ladung Konstantspannungs Phase Konstantstromphase Bulk Modus Wenn das Ladeger t eingeschaltet wird beginnt es mit der Konstantstromphase bis die Gasungsspannung erreicht ist 14 4 V bzw 28 8 V temperaturkompensiert Batterieschonmodus Battery Safe Mode Um die Ladezeit zu verk rzen wird ein m glichst hoher Ladestrom bis zum Erreichen der Gasungsspannung absorption voltage angestrebt Damit aber eine berm ige Gasentwicklung gegen Ende der Konstantstromphase bulk phase vermieden wird begrenzt der Multi Compact Mult
148. s batterie en contact entre eux 12 AD y victron energy 3 5 Connexion des c bles AC Ce produit est issu de la classe s curit I livr avec une prise de mise a la terre de protection Une liaison permanente a la terre doit tre r alis e au niveau de la ou des prises de raccordement AC ou sur la borne de raccordement situ sur Pext rieur du bo tier Voir les instructions suivantes a Le Phoenix Inverter Compact a une tension de sortie flottante Le boitier doit imp rativement tre reli a la terre par la borne de raccordement situ e sur l ext rieur du bo tier Pour le bon fonctionnement d un disjoncteur diff rentiel le neutre de sortie N doit galement tre reli la terre b Le Phoenix Multi MultiPlus Compact est quip d un relais de mise la terre voir appendice 2 qui relie automatiquement le neutre de sortie N la terre en cas d absence d alimentation AC sur l entr e D s qu une alimentation AC est pr sente sur entr e le relais de mise la terre s ouvre avant la fermeture du relais de s curit en entr e Ce dispositif permet d assurer le bon fonctionnement d un disjoncteur diff rentiel en sortie Dans une installation fixe avec neutre identifi une liaison permanente la terre pourra tre r alis e avec le conducteur de terre de l alimentation AC Dans le cas contraire c est le bo tier qu il faut relier la terre Dans une installation mobile par exemple avec prise
149. st atteinte Moins d entretien et de vieillissement quand la batterie ne sert pas le mode Veille Le mode veille intervient lorsque la batterie n a pas t sollicit e pendant 24 heures En mode veille la tension Float est ramen e 2 2V l ment 13 2V pour une batterie 12V pour minimiser le gazage et la corrosion des plaques positives Ensuite la tension est relev e au niveau d absorption une heure par semaine pour galiser la batterie Ce proc d emp che la stratification de l lectrolyte et la sulfatation causes majeures de vieillissement pr matur d une batterie Deux sorties pour charger 2 bancs de batteries Le Multi MultiPlus Compact est quip de 2 sorties isol es dont une peut fournir la puissance totale La seconde sortie destin e l entretien d une batterie auxiliaire d marrage est limit e environ 4 amp res sous une tension l g rement plus basse Pour une meilleure long vit de la batterie compensation en temp rature Le Multi MultiPlus Compact est livr avec une sonde de temp rature de batterie qui fera automatiquement diminuer la tension de charge lorsque la temp rature de la batterie augmente Cette fonction est particuli rement importante pour des batteries tanches ou lorsque des variations de temp rature importantes peuvent se produire 4 AD y victron energy Sonde de tension batterie Pour am liorer encore la qualit de le Multi MultiPlus Compact la possibilit de
150. st einstellbare Zeit der Konstantspannungsphase Nach der Konstantspannungsphase schaltet der Lader herunter auf die Ladeerhaltungsspannung Um die Batterie aufzufrischen schaltet der Lader periodisch zur ck in die Konstantspannungsphase Adaptive Ladekennlinie Die Zeitdauer f r die Konstantspannungsphase ist abh ngig von der Dauer der Konstantstromphase s 4 3 Anschlie end folgt die 24 st ndige Ladeeerhaltungsphase nach der mit verminderter Spannung von 0 8 V bzw 1 6 V f r 12 V bzw 24V Batterien geladen wird Wie bei der vorangegangenen festen Ladekennlinie schaltet der Lader periodisch zur ck zur Konstantspannungsphase Batterieschonmodus Grundeinstellung Um die Ladezeit zu verk rzen wird ein m glichst hoher Ladestrom bis zum Erreichen der Gasungsspannung angestrebt Damit aber eine berm ige Gasentwicklung gegen Ende der Konstantstromphase vermieden wird begrenzt der Phoenix Multi Compact MultiPlus Compact die Geschwindigkeit des Spannungsanstiegs 4 4 2 Weitere Einstellungen Konstantspannungszeit Grundeinstellung 4 Stunden Die Konstantspannungsszeit Einstellung legt die Zeit sowohl in der festgelegten Kennlinie als auch die der maximalen Zeit in der adaptiven Ladekennlinie fest Die maximale Konstantspannungszeit kann zwischen 1 und 8 Stunden eingestellt werden Die Ladeerhaltungsspannung Grundeinstellung 14 4 V 28V Die Ladeerhaltungsspannung kann zwischen 12 16V bzw 24 32V in 0 05 V Schritten eingest
151. tandard a l aide de VEConfigure si n cessaire L intensit de charge est r gl e en usine 75 de l intensit maximale Cette intensit sera dans certains cas trop lev e En r gle g n rale l intensit de charge d une batterie doit tre situ e entre 0 1 et 0 2 fois la capacit totale de la batterie R glages du dipswitch DS1 DS2 DS 1 Hoff DS 1 Hoff DS 2 DS 2 He on DS 3 DS 3 DS 4 DS 4 DS 5 DS 5 zei DS 6 DS 6 DS 7 DS 7 Fij DS 8 DS 8 DS1 off Avec commande a distance DS 2 off DS 1 n est pas utilis et doit toujours tre sur off victron energy 17 Gul y Tensions standard pr r gl es disponibles selon le Typ de batterie DS3 DS4 DS 1 DS 1 DS 2 DS 2 DS 3 DS 3 DS 4 DS 4 DS 5 DS 5 DS 6 DS 7 DS 8 DS 6 DS 7 DS 8 DS3 off DS4 off Typ 1 gel Validation DS3 on DS4 off Typ 2 D placer DS8 de off a on puis a off DS3 off DS4 on Typ 3 Le r glage de DS3 DS4 est active DS3 on DS4 on Typ4 Fr quence du Convertisseur DS5 DS 1 DS 1 DS 2 DS 2 DS 3 DS 3 DS 4 DS 4 DS 5 DS 5 DS 6 DS 6 DS 7 DS 7 DS 8 DS 8 DS5 off 50Hz Validation DS5 on 60Hz D placer DS8 de off on puis a off 18 AD y victron energy AES automatic Economy Switch DS6 DS 1 DS 1 DS 2 DS 2 DS 3 DS 3 DS 4 DS 4 DS 5 DS 5 DS 6 DS 6 DS 7 DS 7 DS 8 DS 8 DS6 off d sactiv Validation DS6 on activ D pl
152. te de carga ptima es del 0 1 0 2 veces la capacidad de la bater a victron energy 15 A y Uso de los conmutadores DIP Configuraci n EER DS 1 DS 1 Hoff DS 2 DS 2 Ex on DS 3 DS 3 DS 4 DS 4 DS 5 DS 5 DS 6 DS 6 DS 7 DS 7 DS 8 DS 8 _ a DS1 off Ver nota El DS 1 no se usa y debe ponerse en Off Nota sobre el DS 2 El DS 2 debe estar en posici n on posici n por defecto cuando no se utilice el panel remoto o el conmutador remoto on off Active los conmutadores DS 3 a DS 8 El DS 2 tambi n debe estar en posici n off cuando se vaya a usar un panel de control remoto o un conmutador remoto on off Tipo de carga de la bater a EEn DS 1 DS 1 Moff DS 2 DS 2 On DS 3 DS 3 Mx x DS 4 DS 4 Mx x DS 5 DS 5 Rea DS 6 DS 6 DS 7 DS 7 ee DS 8 DS 8 f gt DS3 off DS4 off Type 1 gel Guarde los ajustes DS3 DS4 cambiando la posici n DS3 on DS4 off Type 2 off del conmutador DS8 a on y despu s otra vez a DS3 off DS4 on Type 3 off DS3 on DS4 on Type 4 16 victron ener O y S Frecuencia del inversor DS 1 DS 2 DS 3 DS 4 DS 5 DS 6 DS 7 DS 8 ES DS 1 Moff DS 2 Lon DS 3 a DS 4 ES DS 5 Mx x DS 6 DS 7 CG DS 8 DS5 off DS5 on 50Hz 60Hz Guarde los ajustes DS5 cambiando la posici n off del conmutador DS8 a on
153. ti Compact MultiPlus Compact Wenn der Schalter auf on gestellt wird ist das Ger t betriebsbereit Der Inverter schaltet sich ein und die LED Anzeige inverter on leuchtet Spannung die am AC in Anschluss dem Wechselstromanschluss anliegt wird zun chst berpr ft und wenn innerhalb der Spezifikation befunden zum AC out Anschluss dem Wechselstromverbraucheranschluss durchgeschaltet Der Inverter Wechselrichter wird ausgeschaltet die LED Anzeige Charger leuchtet und der Lader nimmt den Betrieb auf Je nach momentan zutreffendem Lademodus leuchtet die LED Anzeige permanent w hrend der Konstantstrom bulk Phase und in der Konstantspannungs absorption Phase oder blinkt in der Ladeerhaltungs float Phase Wenn die Netzspannung als zu hoch oder zu tief befunden wird schaltet sich der Inverter ein Wenn der Frontschalter auf charger only gestellt wird schaltet sich das Ladeger t des Phoenix Multi Compact nur ein wenn Netzspannung vorhanden ist Diese Spannung wird zum Wechselstromverbrauchausgang durchgeschaltet Achtung Wenn Sie den Phoenix Multi Compact MultiPlus Compact nur zum Laden nutzen sollten Sie darauf achten dass der Schalter immer in der Position charger only steht Das verhindert dass sich im Falle eines Stromausfalls der Inverter einschaltet und Ihre Batterien entladen 2 2 Fernbedienung Der Phoenix Multi Compact MultiPlus Compact kann auch mit einer Fernbedienung dem Phoenix Mult
154. tr e 12A Fr quence syst me Multi Compact MultiPlus Compact automatique Convertisseur 50 Hz AES automatic economy switch 16 AD y victron energy off 4 2 R glages modifiables l aide du dipswitch Tensions standard pr r gl es disponibles selon le Type de batterie Type Type de batterie Tension Absorption Tension Float Vdc Dur e maxi Vdc Veille Vdc d Absorption Tension syst me 12 24 48 12 24 48 1 Sonnenschein 144 28 8 57 6 13 8 27 6 55 2 4 heures usine Dryfit A200 Gel 13 2 26 4 52 8 2 Traction 15 0 30 0 60 0 13 8 27 6 55 4 6 heures plaques tubulaires 13 2 26 4 52 8 3 Semi Traction 144 28 8 57 6 140 28 0 56V 5 heures plaques planes 13 2 26 4 52 8 4 Faible teneur 148 29 6 59 2 140 28 0 56V 5 heures Antimoine 13 2 26 4 52 8 La tension d absorption optimale des batteries plomb acide plaques planes d pend de propri t s m caniques et chimiques Les batteries a haute teneur en antimoine peuvent g n ralement tre charg es a une tension d absorption plus basse que celles avec une faible teneur en antimoine Pour plus de pr cisions sur la charge de batteries voir notre livre Electricity on Board disponible en t l chargement libre sur www victronenergy com Consulter le fournisseur des batteries ou la documentation fournie pour connaitre les valeurs pr conis es Modifier les tensions s
155. trol panel should be used 2 3 Special Charger Modes Equalizing Some batteries may need a regular equalizing charge To perform an equalizing charge the Phoenix Multi Compact can charge at a higher voltage 1V above the absorption voltage for a 12V battery 2V for a 24V battery for a period of one hour The charger current is then limited to 1 4 of the specified value The bulk and absorption LEDs will flash alternately during this cycle only on Phoenix Multi Control The equalizing mode results in a charging voltage that may exceed the maximum voltage of DC consumers These should be disconnected when performing an equalizing charge victron energy 5 Gul y Forced Absorption In some cases it may be necessary to charge the battery at the absorption voltage for a specific period of time In the Forced Absorption mode the Phoenix Multi Compact will charge at the normal absorption voltage during the preset maximum absorption period The absorption LED will light up only on Phoenix Multi Control The Phoenix Multi Compact can be switched to one of these modes from the remote control as well as with the aid of the front switch A prerequisite is that all switches front remote remote Control are switched to on and that none are switched to the charger only position Proceed is as follows to switch the Phoenix Multi Compact to either the equalizing mode or Forced Absorption mode REMARK switch quickly from on to
156. trom f r nur kurze Zeit ben tigt wird der Generator eine Nummer kleiner gew hlt und ein eigentlich zu schwach ausgelegter Landstromanschluss gest tzt werden Wird die Last reduziert d h werden Verbraucher ausgeschaltet kann die dann wieder ausreichend vorhandene Energie zum Laden der Batterien genutzt werden Hinweis 1 Um die Funktion PowerAssist nutzen zu k nnen ben tigt ein Phoenix MultiPlus Compact einen Mindeststrom von 2 A sei es vom Landanschluss oder vom Generator Hinweis 2 Einige Generatoren der neuen Generation erzeugen ihren Ausgangswechselstrom ber einen statischen Inverter Weiter reduzieren einige dieser Generatoren ihre Drehzahl wenn nur kleine Verbraucher angeschlossen sind Durch Ausschalten der Dynamic Limit Function VEConfigure kann der MultiPlus Compact den Generator st tzen wenn pl tzlich gro e Verbraucher eingeschaltet werden victron energy 21 O y Externes Alarm Relais und Schaltausgang Grundeinstellung aus Um z B ein Alarm Relais z B Generator Startsignal zu schalten steht ein Transistorausgang zur Verf gung Der maximale Schaltstrom betr gt 40mA bei maximal 66 V Der Transistorschaltausgang kann mithilfe von VEConfigure programmiert werden 4 6 Wartung F r den Phoenix Multi Compact ist keine spezielle Wartung erforderlich Es gen gt v llig wenn alle Anschl sse einmal pro Jahr kontrolliert werden Sch tzen Sie den Phoenix Multi Compact MultiPlus Compact vor Schmutz
157. tron energy 15 A y Dipswitch instellingen Rees DS 1 DS 1 Hoff ps 2 0 DS 2 Me on DS 3 DS 3 DS 4 NM DS 4 DS 5 f DS 5 DS 6 M DS 6 DS 7 M DS 7 DS 8 DS 8 DS1 off Bij gebruik van Remote Control DS 2 off DS 1 wordt niet gebruikt moet altijd op Off staan Accu laad curve DS 1 ff DS 1 DS 2 on DS 2 DS 3 DS 3 DS 4 DS 4 ps5 0 DS 5 ps6 E DS 6 Ge E DS 7 mm DS 8 DS 8 DS3 off DS4 off Typ 1 gel Opslaan druk schakelaar DS 8 naar on en weer DS3 on DS4 off Typ 2 terug naar off De instelling van DS3 DS4 is nu DS3 off DS4 on Typ 3 actief DS3 on DS4 on Typ 4 16 AD y victron energy Omvormer frequentie DS 1 DS 2 DS 3 DS 4 DS 5 DS 6 DS 7 DS 8 on o DS 1 DS 2 DS 3 DS 4 DS 5 DS 6 DS 7 DS 8 ES 50Hz 60Hz DS5 off DS5 on Opslaan druk schakelaar DS 8 naar on en weer terug naar off De instelling van DS5 is nu actief AES Automatic Economy Switch DS 1 DS 2 DS 3 DS 4 DS 5 DS 6 DS 7 DS 8 a DS 1 DS 2 DS 3 DS 4 DS 5 DS 6 DS 7 DS 8 normaal economy DS6 off DS6 on Opslaan druk schakelaar DS 8 naar on en weer terug naar off De instelling van DS6 is nu actief Generator Walstroom i DS 1 Hoff DS 2 on DS 3 DS 4 DS 5 DS 6 DS 7 Bx x DS 8 insLimit 30 Amp insLimit 6 Amp mon zz DD
158. uerschnitt 70 mm2 16 25 35 50 1 5 gt 5m 5 gt 10m 35 50 70 100 140 1 1 5 m kabel sind an jeden geraet vormontiert 24 800 24 1200 12 800 12 1200 12 1600 48 1600 24 1600 48 1200 Empfohlene Batteriekapazit t 40 200 40 400 100 400 150 700 200 700 Ah Anmerkung Der Innenwiderstand ist ein wichtiger Faktor wenn mit Batterien geringer Kapazit t gearbeitet wird Fragen Sie Ihren Lieferanten oder lesen Sie die relevanten Abschnitte aus unserem Buch Strom an Bord das Sie von unserer Webseite runterladen k nnen www victronenergy com 12 My y victron energy Vorgehensweise Gehen Sie beim Anschlie en der Batteriekabel wie folgt vor A Um einen Kurzschluss in der Batterie zu vermeiden sollten Sie mit einem isolierten Steckschl ssel arbeiten Vermeiden Sie dass Sie die Batteriekabel kurzschlie en Schlie en Sie die Batteriekabel wie folgt an das linke rot an das rechte schwarz an siehe Anhang A Ein Vertauschen des Plus und Minus Anschlusses besch digt den Phoenix Multi Compact MultiPlus Compact die interne Sicherung des Phoenix Multi Compact MultiPlus Compact kann ausl sen Ziehen Sie die Muttern fest an um den bergangswiderstand so klein wie m glich zu halten 3 5 Wechselstrom Kabel anschlie en Dies ist ein Ger t der Sicherheitsklasse Geh use geerdet Die Schutzerde an den Wechselstrom Ein und Ausg ngen darf aus Sicherheitsgr nden nicht
159. unterbrochen werden Alternativ kann der au enliegende Erdungspunkt am Geh use benutzt werden Folgen Sie den Hinweisen Der Phoenix Inverter Compact arbeitet mit einem s g schwebenden Wechselstromausgang Der au en am Ger t befindliche Erdanschlusspunkt muss geerdet werden Der N Leiter Ausgang muss immer geerdet sein damit ein Fehlerstrom Fl Schutzschalter einwandfrei arbeiten kann Phoenix Multi Multi Plus Compact Der N Leiter Ausgang wird automatisch mit dem Geh use verbunden mithilfe des Erdungsrelais s Anhang 2 wenn keine Netzspannung anliegt R ckstromschutzrelais ist abgefallen und das Ger t arbeitet im Inverter Betrieb s Anhang 2 Liegt Netzspannung an ffnet das Erdungsrelais bevor das R ckstromschutzrelais schlie t Hat das R ckstromschutzrelais geschlossen wird der geerdete N Leiter des Netzes durchgeschaltet Das gew hrleistet ein sicheres Arbeiten des in den Wechselstromausgangskreis des Phoenix Multi Compact MultiPlus Compact zu schaltenden Fehlerstrom Fl Schalters In einer Festinstallation z B Hausinstallation kann der unterbrechungsfreie Erdanschluss am Ger t durch den Erdleiter des Netzanschlusses gew hrleistet werden In einer ortsver nderlichen Installation Netzanschluss ber ein Landanschlusskabel geht die Erdung verloren wenn das Landanschlusskabel nicht eingesteckt ist In diesem Fall muss das Geh use des Ger tes oder der an Bord befindliche Teil des Erdleiters vom Netzeingang am Ch
160. van de spanning begrenzen Zo wordt overmatig gassen voorkomen 4 4 2 Overige lader instellingen De laadstroom is standaard ingesteld op 75 van de maximale laadstroom Voor veel toepassingen zal deze stroom te hoog zijn Om te voorkomen dat de accu s defect raken is het noodzakelijk om de laadstroom aan te passen naar 0 1 0 2x de accucapaciteit De stapgrootte is 1A Absorptionspanning standaard 14 4V 28 8V De absorptionspanning is in te stellen van 12 16 24 32V De stapgrootte is 0 05 V Absorptiontijd maximale absorptiontijd standaard 4 uur Deze instelling bepaalt bij de fixed laadkarakteristiek hoelang de lader de absorptionspanning aanbiedt Bij de adaptieve laadkarakteristiek bepaalt deze instelling wat de maximale tijd is dat de lader de absorptionspanning aanbiedt De maximale absorptiontijd kan worden ingesteld van 1 tot 8 uur De stapgrootte is 1 uur Floatspanning De floatspanning is in te stellen van 12 16 24 32V De stapgrootte is 0 05 V Herhaalde absorptiontijd standaard 1 uur De herhaalde absorptiontijd kan worden ingesteld van 1 tot 72 kwartier De stapgrootte is 1 kwartier Herhaald absorptioninterval standaard 7 dagen Het herhaald absorptioninterval kan worden ingesteld van 1 tot 45 dagen De stapgrootte is 1 dag victron energy 19 A y 4 5 Bijzondere instellingen alleen instelbaar met VEConfigure software Bulkbescherming aan uit standaard aan Als de lader na 10 uur in de bulkfase te
161. voltage to overcharged set to an incorrect value the correct value The float voltage has been set to Adjust the float voltage to the an incorrect value correct value A defective battery Replace the battery The battery is too small Reduce the charging current or use a battery with a higher capacity The battery is too hot Connect a temperature sensor Battery charge Alt 1 Battery overtemperature Allow battery to cool down current drops to 0 when the absorption voltage is reached gt 50 C Place battery in a cool environment Check for shorted cells Alt 2 Battery temperature sensor faulty Unplug battery temperature sensor from the Multi Reset the Multi by switching it off then wait for 4 seconds and switch it on again If the Multi now charges normally the battery temperature sensor is faulty and needs to be replaced victron energy Gul y 21 6 TECHNICAL DATA 6 1 GENERAL Ventilation Forced cooling internal Temperature limits Operation 20 50 C storage 25 60 C Protection Output short circuit Overload Battery voltage too high Battery voltage too low 230V mains on inverter output DC Input voltage ripple too high Temperature too high transformer Electronics 8 Power stage Battery if sensor connected Humidity 0 95 EMC Electromagnetic compliance EMC 89 33
162. will automatically optimize the process relative to the way the battery is being used The right amount of charge variable absorption time When only shallow discharges occur a yacht connected to shore power for example the absorption time is kept short in order to prevent overcharging of the battery After a deep discharge the absorption time is automatically increased to make sure that the battery is completely recharged victron energy 3 Gul y Preventing damage due to excessive gassing the BatterySafe mode If in order to quickly charge a battery a high charge current in combination with a high absorption voltage has been chosen the Multi Compact MultiPlus Compact will prevent damage due to excessive gassing by automatically limiting the rate of voltage increase once the gassing voltage has been reached Less maintenance and aging when the battery is not in use the Storage mode The storage mode kicks in whenever the battery has not been subjected to discharge during 24 hours In the storage mode float voltage is reduced to 2 2 V cell 13 2 V for a 12 V battery to minimize gassing and corrosion of the positive plates Once a week the voltage is raised back to the absorption level to equalize the battery This feature prevents stratification of the electrolyte and sulphation a major cause of early battery failure Two outputs to charge 2 battery banks The Multi Compact MultiPlus Compact features 2 outputs of which 1 can

Download Pdf Manuals

image

Related Search

Related Contents

USER GUIDE - The Cattle Information Service    Whirlpool Cooktop W10458809B User's Manual  Assembly and operating instructions Englisch  Bintec-elmeg IP-S290Plus Wired handset Black, Blue  Valueline VLMP60891B10 mobile device charger  Sportsman SM07492 Use and Care Manual  Rapport moral et rapport d`activité 2013  Samsung SGH-E760 Vartotojo vadovas  EpiQuik™ Tissue Methyl-CpG Binding Domain Protein 2  