Jandy Housing for Wet Niche Fixtures Installation Manual WARNING

image

Contents

1. NeverLube valves are warranted for the life of pool and or spa on which they were originally installed This warranty is limited to the first retail purchaser is not transferable and does not apply to products that have been moved from their original installation sites The liability of Jandy Pool Products Inc shall not exceed the repair or replacement of defective parts and does not include any costs for labor to remove and reinstall the defective part transportation to or from the factory and any other materials required to make the repair This warranty does not cover failures or malfunctions resulting from the following 1 Failure to properly install operate or maintain the product s in accordance with our published Installation Operation and Maintenance Manuals provided with the product s 2 The workmanship of any installer of the product s Not maintaining a proper chemical balance in your pool and or spa pH level between 7 2 and 7 8 Total Alkalinity TA between 80 to 120 ppm Total Dissolved Solids TDS less than 2000 Abuse alteration accident fire flood lightning rodents insects negligence or acts of God Scaling freezing or other conditions causing inadequate water circulation Operating the product s at water flow rates outside the published minimum and maximum specifications Use of non factory authorized parts or accessories in conjunction with the product s Chemical contamination of comb
2. un Rebar Mounting N Flange 4 places Grounding Figure 3 Plastic Niche Bonding Wire Installation Nylon Screw Included in Kit j Plastic Cover Included in Kit Figure 4 Plastic Niche Cover and Nylon Screw for Plastic Niche Page 5 3 Installation Instructions for Stainless Steel Niches SSNICLRG AND SSNICSM a Locate a position for the installation of the niche and light fixture so that the top of the lens will be a minimum of 18 below normal water level Position niche between adjacent rebars so that the niche is held on four sides by sections of rebar It may be necessary to add sections of rebar or to move existing sections in order to secure niche in place b Attach conduit to the back of niche using the proper thread sealant A threaded 1 NPT connection is attached to the back of the niche A threaded 1 Y2 NPT reducer is included with the niche to permit the use of Y2 metallic conduit If nonmetallic conduit is used then a threaded bushing will be required not included with niche c Using tie wire attach the niche housing to the rebar Ensure that the niche is the proper forward distance from the rebar so that the top surface of the niche will be flush with the finish surface NOTE Be sure to orient the niche so that the TOP marking of the niche is in the 12 o clock position d Connect bonding wire from rebar to rear bonding lug of niche outside of the niche e
3. Canada the surface of the water in the The Jandy Niche is designed to be installed in the pool pool or spa See Figure 1 or spa walls e The wet niche must be properly electrically bonded and grounded via the No 8 AWG ground connector located at the rear of the niche See Figure 1 1 Installation During New Construction Ensure that the pool or spa meets the requirements of the current National Electrical Code and all local codes and ordinances A licensed or certified electrician y 7 f 2 Installation Instructions for Plastic Niches must install the electrical system to meet or exceed those requirements before the Niche fixture housing PLNICLRG AND PLNICSM is installed Some of the requirements of the National a Locate a position for the installation of the niche Electrical Code which the pool and spa electrical and light fixture so that the top of the lens will systems must meet are as follows be a minimum of 18 below normal water level a The lighting circuit must have a Ground Fault Position niche between adjacent rebars so that the Circuit Interrupter GFCD for 120 volt models niche is held on four sides by sections of rebar It and must have an appropriately rated circuit may be necessary to add sections of rebar or to breaker move existing sections in order to secure niche in b The Junction Box or for 12 volt models the pane low voltage transformer must be located at least b Attach conduit to
4. H0284400A Installation Data Jandy Installation Manual Jandy Housing for Wet Niche Fixtures For Gunite Pool and Spa Installations Plastic Model Nos PLNICLRG and PLNICSM and Stainless Steel Model Nos SSNICLRG and SSNICSM SSNICLRG SSNICSM PLNICLRG PLNICSM 4 WARNING FOR YOUR SAFETY This product must be installed and serviced by a professional pool spa service technician The procedures in this manual must be followed exactly Failure to follow warning notices and instructions may result in property damage serious injury or death Page 2 Jandy IMPORTANT SAFETY INSTRUCTIONS PERTAINING TO A RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS READ AND FOLLOW ALL INSTRUCTIONS When installing and using this equipment basic safety precautions should always be followed including the following A WARNING RISK OF ELECTRICAL SHOCK OR ELECTROCUTION This underwater niche must be installed by a licensed or certified electrician in accordance with the National Electrical Code and applicable local codes and ordinances Improper installation will create an electrical hazard which could result in death or serious injury to pool or spa users installers or others due to electrical shock and may also cause damage to property Read and follow the specific instructions below A WARNING Before installing this underwater niche read and follow all warning notices and instructions accompanying this niche Failure to fo
5. If rigid nonmetallic conduit is used a 8 AWG bonding wire is required to run through conduit from the junction box to the bonding grounding lug inside of niche Seal the wire lug connection with a listed sealant See Figure 6 If metallic conduit is used a 8 AWG bonding wire is not required f The outside bonding connection must be inspected before the concrete pouring shooting operation It is also necessary to keep concrete or gunite from hardening on the outer edge and flange of the niche during pouring shooting g Remove the nylon screw and attach plastic niche cover to opening of niche prior to the concrete gunite pouring shooting operation See Figure 7 The cover prevents concrete or gunite from entering the inside of the niche during the pouring shooting operation h Once the concrete gunite has completely dried and prior to plastering tear outer portion away from Jandy 1 1 2 Reducer 3 Included in Kit Bonding Lug Figure 5 Stainless Steel Niche Kit Components Rebar Mounting Holes Bonding 8 places Wire Bonding Grounding Lug Figure 6 Stainless Steel Niche Bonding Wire Installation Nylon Screw Included in Kit Plastic Cover Included in Kit Figure 7 Plastic Niche Cover and Nylon Screw for Stainless Steel Niche cover Plaster up to the top edge of niche 4 Part Lists The Parts Lists and Exploded View are shown on the next page Page 6 Jan
6. alling our technical support department at 707 776 8200 extension 260 All returned parts must have a Returned Material Authorization number to be evaluated under the terms of this warranty a d Jandy Pool Products Inc 6000 Condor Drive Moorpark CA USA 93021 707 776 8200 FAX707 763 7785 Litho in U S A Jandy Pool Products Inc 0701 H0284400A
7. dy Table 1 Parts List Plastic Pool and Spa Niche PLNICLRG and PLNICSM ltem No Part Number Description 1 R0460800 Niche Misc Kit Plastic Pool and Spa 10 24 Screws Grounding Lug 10 24 Nylon Screws Gunite Protection 1 Threaded Plug 1 45 Sweep Elbow 1 to 3 4 Reducer E gt A 2 Ny 2 RO461000 Niche Cover R Kit Pool Niche Cover Pool 1 3 R0461100 Niche Cover R Kit Spa Niche Cover Spa 1 Figure 8 Plastic Pool and Spa Niche PLNICLRG and PLNICSM Exploded View Table 2 Parts List Stainless Steel Pool and Spa Niche SSNICLRG and SSNICSM Item No Part Number Description 1 R0460900 Niche Misc Kit Stainless Steel Pool and Spa 10 24 Screws Grounding Lug 10 24 Nylon Screws Gunite Protection 1 to 1 2 Threaded Reducer E gt N 2 RO461000 Niche Cover R Kit Pool Niche Cover Pool 1 3 R0461100 Niche Cover R Kit Spa Niche Cover Spa 1 l A Figure 9 Stainless Steel Pool and Spa Niche SSNICLRG and SSNICSM Exploded View Page 7 Jandy NOTES LIMITED WARRANTY Thank you for purchasing Jandy pool and spa products Jandy Pool Products Inc manufacturer of Jandy products warrants all parts to be free from manufacturing defects in materials and workmanship for a period of one year from the date of retail purchase with the following exceptions AquaLink RS units installed with Jandy Surge Protection Kits will be covered for two years
8. llow safety warnings and instructions can result in severe injury death or property damage Call 707 776 8200 or visit our website www jandy com for additional free copies of these instructions ATTENTION INSTALLER This manual contains important information about the installation and safe use of this product This information should be given to the owner operator of this equipment NOTICE The Jandy Pool and Spa niches are intended for installation in fresh water and salt water swimming pools and spas It is important to ensure that the lights in which the niches are installed are intended for their appropriate application either fresh water or salt water Jandy Compatible Light Fixture Part Numbers Use the large niches SSNICLRG and PLNICLRG with the following Jandy Lights P N JPL120XXX P N JPL12XXX P N CPHVXXXXXXXX P N CPLVXXXXXXXX P N WPHVXXXXXXXX P N WPLVXXXXXXXX Use the small niches SSNICSM AND PLNICSM with the following Jandy Lights P N JSL120XXX P N JSL12XXX P N WSHVXXXXXXX P N WSLVXXXXXXXX SAVE THESE INSTRUCTIONS Page 3 Jandy This document gives instructions for installing the Jandy Niche for gunite pool and spa installations The instructions must be followed exactly Read through the instructions completely before starting the procedure The wet niche must be properly installed so that the top edge of the underwater light s lens is at least 18 inches below not more than 48 inches below in
9. rom the rebar so that the top surface of the niche will be flush with the finish surface NOTE Be sure to orient the niche so that the TOP marking of the niche is in the 12 o clock position d Connect 8 AWG bonding wire from rebar to rear grounding lug of niche outside of the niche e If nonmetallic conduit is used a 8 AWG bonding wire is required to run through conduit from the junction box to the bonding grounding lug inside of niche Seal the wire lug connection with a listed sealant See Figure 3 f The outside bonding connection must be inspected before the concrete pouring shooting operation It is also necessary to keep concrete or gunite from hardening on the outer edge and flange of the niche during pouring shooting g Remove the nylon screw and attach plastic niche cover to opening of niche prior to the concrete gunite pouring shooting operation See Figure 4 The cover prevents concrete or gunite from entering the inside of the niche during the pouring shooting operation h Once the concrete gunite has completely dried and prior to plastering tear outer portion away from cover Plaster up to the top edge of niche i APVC 1 Plug is provided with niche for pressure testing of conduit line before installation of light fixture _Jandy 1 3 4 Reducer Included in Kit Na 45 Degrees Sweep Elbow Included in kit Bonding Lug Figure 2 Plastic Niche Installation
10. the back of niche using the eight 8 inches above water level at least four 4 proper PVC CPVC primer and glue See Figure inches above ground level and at least four 4 2 A 1 PVC 45 degree sweep elbow is included feet from the edge of the pool or spa See Figure 1 with the niche to direct the conduit pipe upwards toward the junction box A 34 reducer is also included with the niche to permit the use of 34 conduit pipe Make sure to follow the primer and glue manufacturer s instructions for the preparation procedures and curing times c The light fixture and all metal items within five 5 feet of the pool or spa must be properly electrically bonded to a reliable point of grounding Seal the wire lug connection with a listed sealant To GFCI Circuit a Breaker and nt 8 min Junction Box or Low 5 AR D Voltage Transformer to the le SSE ASS KW max water level of the pool 18 min to top of Lens Conduit 8 AWG Ground Concrete must be cut Connector bonded N back around niche to allow for a compacted plaster seal 11 50 Coil 4 ft of light cable around fixture 16 Figure 1 Pool Niche Installation Page 4 c Using tie wire attach the niche housing to the rebar Jandy models PLNICLRG and PLNICSM have four 4 outer flanges with 14 holes which should be used to route the tie wire through to secure the niche to the rebar Ensure that the niche 1s the proper forward distance f
11. ustion air or improper use of sanitizing chemicals such as introducing sanitizing chemicals upstream of the heater and cleaner hose or through the skimmer Overheating incorrect wire runs improper electrical supply collateral damage caused by failure of O Rings DE grids or cartridge elements or damage caused by running the pump with insufficient quantities of water LIMITATION OF LIABILITY This is the only warranty given by Jandy Pool Products Inc No one is authorized to make any other warranties on Jandy Pool Products Inc s behalf THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY JANDY POOL PRODUCTS INC EXPRESSLY DISCLAIMS AND EXCLUDES ANY LIABILITY FOR CONSEQUENTIAL INCIDENTAL INDIRECT OR PUNITIVE DAMAGES FOR BREACH OF ANY EXPRESSED OR IMPLIED WARRANTY This warranty gives you specific legal rights You may also have other rights which vary by state or province WARRANTY CLAIMS For prompt warranty consideration contact your dealer and provide the following information proof of purchase model number serial number and date of installation The installer will contact the factory for instructions regarding the claim and to determine the location of the nearest designated service center If the dealer is not available you can locate a service center in your area by visiting www jandy com or by c