Contents

1. Selecting the number of active Zones 1 Press and hold down the Zone button this will enter programming mode 2 The Zone number will flash and can be changed using the up arrow button 3 Press the red button to confirm the number of Zones Unused zones will be cleared i e no LCD information will display and no LED s will work for that Zone An audible beep will be heard if any of the unused Zone buttons are pressed but no action will be taken 4 Press Zone button to exit the programming mode Setting the time that the lights stay on When a detector is triggered and if that Zone has been set to the automatic mode green LED the lights will turn on and stay on for the time programmed using the TIME setting in the programme software This can be selected to be 1 2 3 4 5 8 12 16 or 24 minutes using the red and arrow buttons When set simply press any of the ZONE buttons to exit the programming mode Optional DygiZone slave controllers Up to two additional DygiZone controllers can be connected to the system additional Expansion Units or power supply will be required to provide the 2 Volt supply Only the Master controller can be used to set the programme options but different voice messages can be recorded on the remotely located Slave controllers The keypad can also be locked on the Slave controllers otherwise the slaves will mimic the Master Changing a button selection on the Master DygiZone will instantly change the setti
2. up mode by pressing any of the zone buttons The time will now display on the LCD clock Pg 5 Walk test Walk Test Mode has to be selected for each Zone that is being walk tested In this mode as each detector is activated the audible beep will sound amp the relevant Zone amp PIR Number is displayed on the LCD The external lights connected to that Zone will turn on for 4 seconds each time a beam is crossed Each Zone has to be tested individually When in programming mode i e after pressing and holding one of the Zone buttons until the LCD display icons show use the red button to scroll to the flashing hand icon Select the walk test mode by pressing the up arrow when the hand icon is showing The blue LED flashes all the time until the walk test mode has been exited To exit the walk test mode press the red button once an audible beep will be heard The DygiZone will automatically cancel the walk test mode after five minutes from last trigger Switching the lights on amp off at pre set times in each individual Zone Each Zone can be programmed to automatically switch the external lights on amp off at pre set times the on amp off times must be on the same day as each other and must not cross 00 00 Each Zone has two programmable timers T amp T2 Using the red and arrow buttons advance to the TI ON time When the hour digits begin to flash enter in the hour at which you want the lights to turn on press the r
3. LED s that are required will be displayed Zone Status Icons only visible when the zone button is pushed At the top and in the middle of the LCD three zone status icons will be displayed in various combinations depending on how the zone has been set up 1 A light bulb icon represents external lights are on from a detector activation manual override mode or timer operation and mimics the yellow LED 2 The musical note icon is shown when the audible mode is selected and mimics the red LED 3 If voice message mode has been selected vs beep then the microphone icon will also display on the LCD 4 The stick man icon represents the automatic mode and mimics the green LED All of these are more fully described below Pg 2 LED lights explained Red Audible Mode either beep mode or voice message mode Green Automatic Mode works in conjunction with the photocell in the detector The external security lights will only be activated if it is dark and thereby saves energy Yellow Manual Override the external security light will now remain on irrespective of detector status useful for barbeques or when working outside in the dark for long periods Yellow Lighting Activated the external security lights have been activated by a detector and will remain on for the pre set time Yellow Timer Active the external security lights are on because the Timer or Timer 2 options are programmed to be active The DygiZone Cont
4. N LOAD ee ZONE 4 12VvDC 120mA LOAD 2 6 1500VA MAX BLUE SIGNALS FROM GJD DETECTORS CAUTION TO BE FITTED BY QUALIFIED PERSONNEL ONLY ADDITIONAL DYGIZONE CONTROLLER GJD DETECTORS GJD DETECTORS Cc gt JILO T AKE CON TROL Specifications Supply 2VDC 20 mA standby 100 mA triggered with message playback Display Blue back lit LCD display showing real time clock detector activation and zone status Audible Internal warning tone with individual tones for each zone or selectable 10 second voice recordable message for each zone Control Four individual zone buttons for selecting zone status and programming options System configuration Normally Master and Slave DygiZone One additional Slave can be added if required Requires GJD Expansion Units Time control Two individual on off timers per zone Mounting Indoor use only Mount in a clean dry location Can be mounted on a standard single or double flush backbox Temperature 100C to 55 C Dimensions 134 W x87 H x 30 D mm Weight 190g NET 260g GROSS DygiZone 8 Displays amp Controls Voice Message Selected Indicator Walk Test Mode Indicator Light On Indicator Automatic Mode Indicator Audible Mode Indicator Zone Active Indicator PIR Active Indicator Number of Active Zones T Output SECS Time On Indicator MINS 2 or 24 hour Clock Setting Red LED Light Green LED Light Yello
5. Setting the sensitivity of Detectors Pulse Count The number of beams pulse count that need to be triggered before an alarm output activates can be set atl 2 or 3 can be selected Note when using a DygiZone with GJD detectors where the pulse count is set on the detector itself ensure that the detector pulse count is set to This will apply to D TECT OPAL ELITE and OPAL RFX GJD detectors but does not apply to the OPAL XL detector Mode Settings One of five modes can be programmed for each Zone Mode 24hr Lights operate day and night with detection when auto is selected Mode 2 Link Zone Detectors on Zone also activate lights on Zone 2 when auto is selected Mode 2 Link Zone 2 Detectors on Zone 2 also activate lights on Zone when auto is selected Mode 2 Link Zone 3 Detectors on Zone 3 also activate lights on Zone 4 when auto is selected Mode 2 Link Zone 4 Detectors on Zone 4 also activate lights on Zone 3 when auto is selected Mode 3 24 L Outside light will operate day and night with detection according to the Link settings above Mode 4 STD Outside lights will only operate at night with detection Detectors on that Zone will only operate that zone Mode 5 ALL All lights on all Zones that have Mode 5 selected are activated at night with detection from any Zone with Mode 5 selected Any Zones with ALL selected will be treated as a group TSEC output When this option is selecte
6. bout 6 seconds during the trigger state and will remain on after the trigger has occurred VY The text remains on for a time duration time on equal to the time that has been pre set in the Mins Setting If the DygiZone is triggered during the hours of darkness WY The external security light will also be activated for the pre set time Note if another PIR activation occurs on any other zone then the text will be displayed for that new zone for the same pre programmed time on duration Recording a voice message to audibly indicate which zone has been activated 1 Press and hold the red button until the microphone symbol appears on the LCD 2 Press the required Zone button once and then release As you release the zone button a horizontal bar with ten segments will appear below the microphone symbol on the LCD This indicates the amount of recording time available where each segment is equivalent to one second therefore a ten second message can be recorded 3 Speak into the microphone on the front cover of the DygiZone to indicate location e g patio area front door side garden etc 4 When you have finished speaking into the microphone quickly press the zone button again there will be no audio beep 5 The recorded message will now automatically play back If you are Pg 3 satisfied with the message do nothing but if you wish to re record the message repeat steps to 5 You now need to set up each recorded message for
7. d on the GJD Expansion Unit the TSEC output will provide a 2 Volt positive switched signal for the selected time in seconds i e off 1 5 10 20 or 30secs Setting the clock to 12 hr or 24 hr mode or to Clock Off Display The clock display must be set to 24 hr before the clock time can be set Use the red and arrow buttons to advance and to set the clock mode If 12 HR mode is selected AM and PM symbols will automatically appear The clock can also be selected to display 24 hour time or not to display time clock off Note the two timers for each zone will automatically display the time in the format as selected above If the power is turned off and then on without holding down the Zone amp 4 buttons both the illuminated zone LED s and programme settings will also remain as they were prior to power down the clock display will however be reset to 00 00 Setting the clock Press and hold down any Zone button until the LCD icon for that Zone appears and that Zone button is flashing blue the number of zones connected will also be flashing i e the number 2 3 or 4 2 Press the red button six times and the hour digits will begin to flash 3 Set the hours by using the up arrow and press the red button again to set the hour required 4 The minute digits will now begin to flash set the minutes in the same way as the hours Now press the red button Now that the clock is set to the correct time exit the clock set
8. ed button repeat for the minutes and press the red button again to set the time Repeat for the TI OFF Time and repeat for the T2 timer Note if the timers are not required they should be set to 01 00 for on and off times default settings Default settings When you purchase a DygiZone it has already been pre programmed with suggested parameters which are the DEFAULT settings To return the DygiZone to its default settings in the programming mode use the red button to scroll to the DEFAULT text icon and when flashing select press the up arrow key Caution this will return all settings to default and will also reset the clock Default settings are Zones active 4 Light on time minute Pulse count T seconds 5 Clock mode 24 hr Mode 4 Power up reset reverts to default settings This would normally be initiated by a qualified electrician or security systems installer Remove power from the DygiZone Press and hold down both the Zone amp 4 buttons and then re apply the power The clock will be reset and the programme will revert to default settings where all the Zones are set to audible and auto modes i e the red and green LED s will be lit on all Zones Note after a power down amp power up the detectors connected to the GJD expansion Unit will not activate for the following 2 or 3 minutes Maintenance mode The spanner icon flashes when the keypad is locked and is steady when the supply voltage to
9. efaults to 00 00 VY The symbol M appears on the DygiZone which is configured as the master controller The letter M does not appear when setting up a DygiZone as a slave controller The three zone LED s will display whatever zone state has been last programmed or the default setting The default setting is audible and automatic for all active zones Zone Indicator Icons explained Along the bottom of the LCD display up to three sub zone circular icons will be displayed above each numbered Zone button These will only be displayed when an associated detector connected to Al A2 or A3 on the Expansion Unit is activated When corresponding detectors connected to Al A2 or A3 inputs are activated then VY The LCD screen will display the zone numbers 2 and 3 Y A circle will appear around the zone number if that sub zone detector is activated The circle flashes on the screen in the same way as the PIR text whenever a PIR is triggered i e the circle flashes for 8 seconds upon activation and then remains on for pre programmed time duration time on After that time as elapsed the circle will disappear Note the numbers 2 or 3 always remain steady and never flash When the PIRs have not been activated VY The large circular blue Zone buttons 1 4 will not be illuminated Y LCD blue backlight will be switched off VY The clock and M display will remain visible but all other icons on the LCD are turned off WY The zone status
10. ngs on the Slave controllers Changing a button selection on either of the Slave controllers will instantly change the setting on that Slave and the Master the setting on the other Slave will change within one minute It is recommended that the DygiZone which will be used the most should be configured as the Master Pg 4 DugiZone Wiring Diagram DYGIZONE CONTROLLER MASTER MAINS VOLTAGE CONNECTIONS SLEEVED EARTH CABLES ao etc MAINS SUPPLY VIA LOAD enea Nhoa e Ls Tg ewe a AA eee T I OPTIONAL PIEZO SOUNDER SUITABLE RCD MCB ZONE 1 ii a pD CONTROL Pa 12VDC 50mA MAX MAINS SS LIVE 2 4 12vDC s SUPPLY Ga LL BROWN LOAD E E ZONE 2 120mA LOAD 2 1500VA MAX S BLUE WARNING DISCONNECT FROM SIGNALS FROM GJD DETECTORS YELLOW SOLITAIRE EXPANSION UNIT 1 MAINS SUPPLY BEFORE REMOVING COVER FOR ZONES 1 AND 2 2 O 6 l YELLOW Appmona O O io Om Om O DO EXPANSION DUAL CABLE SINGLE CABLE O _ UNITS 3 2 1 3 2 1 CLAMPING CLAMPING BAJO PONE S 2 ZONE 2 ZONE 1 GJD DETECTORS GJD DETECTORS BLUE om Cc O GREEN ADDITIONAL D EXPANSION e O UNIT S BLACK 0 ZONE 3 4 PLUG TYPE FUSE SLEEVED EARTH CABLES gt SOLITAIRE IIll BROWN EXPANSION UNIT 2 Ji ME OPTIONAL PIEZO SOUNDER raa FOR ZONES 3 AND 4 C ouch A Si eae BROWN D 12VDC 50mA MAX MAINS RED s SUPPLY jammy IE BROW
11. rol and Monitoring Status can be set individually for each Zone as follows Pressing a Zone button selects the Zone to be set up The LED s and the LCD display icons will display the current status e g Green LED and stick man means auto mode has been selected 2 A second press on the same button will now light the red LED green LED turns off The musical note icon will now show on the LCD plus a microphone symbol if voice message has been selected 3 Pressing the zone button again will turn off all the LED s amp icons 4 Press once more and the yellow LED lights and the light bulb icon displays in the LCD This now sets the Dygizone to manual mode for that specific zone and the lights will come on and stay on 5 One more press and both the green and the red LED s come on indicating that audible and automatic mode have been selected Locking the key pad Locking the key pad prevents accidental programme or setting changes To lock press and hold down Zone buttons and 4 at the same time a single beep will be heard and the spanner symbol on the keypad will flash to confirm that the key pad is locked To unlock repeat the action and two beeps will be heard and the spanner symbol will disappear When a PIR detector in a zone is triggered the following zone information is displayed LCD Information and Text VY PIR text will flash for approximately 8 seconds for that zone VY The blue LCD backlight will come on for a
12. the appropropriate zone 6 Press and hold down the red button until the microphone symbol appears in the LCD and then release 7 Now press and continue to hold down the zone button for which the voice message is to apply until an audible beep is heard release the zone button and the programming has been completed The voice message mode can be confirmed by pressing the zone button once and a microphone symbol will appear on the LCD if audible mode has been pre selected Note I the normal default status for sensor activation is an audible beep i e one beep for Zone two beeps for Zone 2 and so on Note 2 it is possible to mix both audible beeps and recorded messages e g Zone could be in beep and Zone 2 could be in recorded voice playback To change from a voice message to a beep repeat Steps 6 amp 7 Engineer programming Whichever Zone requires adjustment press and hold down that Zone button until the programming options show on the LCD display The ZONES number will be flashing on the LCD display to change this option press the UP button until the required number is showing then press the RED button If no adjustment is required press the RED button This will store the change and move on to adjust the TIME MINS Repeat the above process until all changes have been completed then press any Zone button to exit programming If no buttons are pressed for 30 seconds the DygiZone will automatically exit the programming mode
13. the DygiZone is outside the specification i e below 9 Volts or more than 14 Volts IMPORTANT If the keypad is not locked and the spanner icon is showing steady please call a maintenance engineer Copyright GJD Manufacturing Ltd December 2006 Information correct at time of going to press errors and omissions accepted GJD reserve the right to improve or change specifications without prior notice GJD D 1M 12 06 Pg 6 DygiZone 1 THE ADVANCED MULTI FUNCTION 4 ZONE SECURITY LIGHTING CONTROLLER amp ENUNCIATOR INSTALLATION MANUAL Cc gt JLO T AKE C ONTROL GJD Manufacturing Ltd Unit 2 Birch Industrial Estate Whittle Lane Heywood OL10 2SX Tel 44 0 1706 363998 Fax 44 0 1706 363991 Email info gjd co uk Web www gjd co uk z o e Master wiring identification CABLE FROM EXPANSION UNIT SLAVE WIRING FROM MASTER SIX CORE DyGIZONE FOUR CORE Red t ve 2 Volt Red t ve 2 Volt Black ve QVolt Black ve QVolt Blue Clock C Blue Clock C Yellow Data D White Remote R Green Data E White Remote R Power up the DygiZone and you will see Y All the LED s red yellow green and blue buttons will flash Y All LCD icons will light up there is no audible noise The blue LCD backlight does not come on V The display will automatically clear after minute or if any button is pressed When the display clears and if nothing is activated VY The LCD displays the clock time automatically d
14. w LED Light ZONES 3 T SECS OFF QE DO Recorded Voice Message Horizontal Bar Programmable Timers On Off Indicator Pulse Count Indicator 1 2 or 3 DugiZone HC CJ ZONE 2 ACTIVE Q PIR 8 TRIGGER 0 ZONE i eee Microphone ic Copyright GJD Manufacturing Ltd December 2006 Information correct at time of going to press errors and omissions accepted GJD reserve the right to improve or change specifications without prior notice 4 Zone Buttons TIME MINS 24 CLOCK 14 OFF T1 ON or 412 OFF PULSE 3 DEFAULT Iu eM MODE 5 Red Button Default Setting Indicator Cc gt JILO CON TROL Clock Display AM or PM appears automatically in 12 hour mode Mode Display 1 5 Master Controller Indicator no symbol indicates if controller is acting as a slave Keyboard Locked Indicator also indicates when voltage is out of specification Sub Zone Detector Indicators circle appears only when a detector has been triggered Up Button GJD Manufacturing Ltd Unit 2 Birch Industrial Estate Whittle Lane Heywood OL10 2SX Tel 44 0 1706 363998 Fax 44 0 1706 363991 Email info gjd co uk Web www gjd co uk GJD D IM 12 06 2

Download Pdf Manuals

image

Related Search

Related Contents

Télécharger - Fédération Française de Parachutisme  Sandberg Adaptor Toslink to MiniPlug  Télécharger le programme de la soirée  APC C2C surge protector  Taylor h-71 h-84 Marine Heating System User Manual  Phonix S8160TNS mobile phone case  ri-thermo® N  IFB 48 - RSF Elektronik  Page 1 Page 2 このたびは、 サイ リスタ式単相電力調整器PAC2 6    