American Standard 6047.121.002 Installation Guide

image

Contents

1. e 6047 122 1 LP S 4 1 4 to 5 1 4 ILT JT ROUGH IN _ DIMENSION 687mm 21 CRITICAL 6047 121 ROUGH IN DIMENSION 295 mm 11 1 2 FOR 1 1 2 TOP SPUD FIXTURES RECOMMENDED TOOLS Fig 2 Teflon Tape Flat Blade Screwdriver For adjusting Supply Stop Adjustable Wrench Tape Measure Hacksaw Tubing Cutter File For Sweat Connection Solder and Torch 2 5mm Hex Wrench 1 5mm Hex Wrench h aa ai a PRIOR TO INSTALLATION Note Prior to installing the Selectronic Flush Valve the following items must be installed 1 Toilet 2 Drain line 3 Water supply line IMPORTANT e All plumbing must be installed in accordance with applicable codes and regulations e Water supply lines must be sized to provide an adequate volume of water for each fixture GENERAL DESCRIPTION MANUAL FLUSH VALVE Exposed Flushometer for 1 1 2 Top Spud Fixtures Exclusive self cleaning piston operated flush valve OPERATING PRESSURE Overall Range 20 125 psi Recommended 25 psi flowing 80 psi static 6047 122 es FLOW REQUIREMENT 25gpm 94 6 L min 6047 121 Water pressure over 80 psi is not recommended with most plumbing fixtures Right or Left Hand Installation See Section 8 for converting Flush Valve to Left Hand Installation e Flush all water lines prior to operation See Step 5 Dirt and debris can cause flush valve t
2. MANUAL FLUSH VALVE Exposed Flushometer 6047 Series for 1 1 2 top spud Toilets 7017 Series FOR TOP SPUD APPLICATIONS CLOG RESISTANT e Self cleaning piston valve prevents clogging and reduces maintenance OPERATING PRESSURE e Overall Range 20 125 psi e Recommended 25 psi flowing 80 psi static FLOW REQUIREMENT e 25gpm 94 6 L min e Flush valves include sweat solder kit Water pressure over 80 psi is not recommended with most plumbing fixtures Certified to comply with e ASSE 1037 e ANSIZASME A112 19 2 e ADA Compliant 2011 AS America Inc M965022 Rev 1 3 Installation Instructions Americam Standard NOTE TO INSTALLER Please give this manual to the customer after installation To learn more about American Standard Faucets visit our website at www americanstandard com or U S customer s e mail us at faucetsupport americanstandard com For Parts Service Warranty or other Assistance please call 1 800 442 1902 In Canada 1 800 387 0369 In Toronto Area only 1 905 3061093 Thank you for selecting American Standard the benchmark of fine quality for over 100 years To ensure that your installation proceeds smoothly please read these instructions carefully before you begin U N PAC KI NG All American Standard Products Are Water Tested At Our Factory Some Residual Water May Remain In The Valve During Shipping 1 Remove the Flush Valve items from the carton The ill
3. for a left or right hand installation REMOVE COVER rA a D 3 COUNTER CLOCKWISE S Ll OPENS CONTROL STOP eR CLOCKWISE amp CONTROL STOP Right or Left Hand Installation Left Hand Right Hand M965022 Rev 1 3
4. o run continuously e With the exception of Supply Stop Inlet DO NOT use pipe sealant or plumbing grease on any valve component or coupling e Protect the chrome or special finish on the Flushometer DO NOT USE toothed tools on finished surfaces to install or service these valves Also see Care and Cleaning section of this manual e This product contains mechanical and or electrical components that are subject to normal wear These components should be checked on a regular basis and replaced as needed to maintain the valve s performance M965022 Rev 1 3 fl INSTALL SWEAT SOLDER ADAPTER Fig 3 CAUTION PiN Note Install Optional Sweat Solder Adapter Supplied for copper pipe supply line Fig 3 1 Measure the distance A from the finished wall to the center of the inlet spud on the fixture 2 Cut the supply pipe 1 1 4 A B C shorter then the measurement taken in Step 1 File any rough edges off the end of the supply pipe 3 Clean the end of the supply pipe Push the threaded Adapter on until it is seated against the internal stop Sweat the Adapter to the pipe A INSTALL COVER TUBE WALL ESCUTCHEON and SUPPLY STOP Fig 4 1 Measure from finished wall to first thread of Adapter or threaded supply pipe dimension X Cut COVER TUBE 1 to length X Apply Teflon Tape to the threaded end of the Adapter or supply pipe Fig 4a 2 Push the COVER TUBE 1 into the WALL ESCUTCHEON 2 Slide both ont
5. o the SUPPLY PIPE 3 Fig 4b 3 Push the COVER TUBE 1 in to expose the threads of the supply pipe Fig 4c With a wrench thread the SUPPLY STOP 4 onto the SUPPLY PIPE 8 Align and tighten Fig 4c 4 Pull COVER TUBE 1 against SUPPLY STOP 4 and push WALL ESCUTCHEON 2 against finished wall k INSTALL DOWN TUBE AND VACUUM BREAKER Fig 5 1 Place the SPUD FLANGE 1 over the spud on the Fixture 2 Thread SPUD COUPLING NUT 2 onto Spud Make sure SEAL WASHER 3 and FRICTION WASHER 4 are installed Do not tighten fully 3 Insert the DOWN TUBE 5 into the SPUD COUPLING NUT 2 and push it down Note If cutting Down Tube 5 to size note that Critical Line C L on Vacuum Breaker must typically be 6 152mm minimum above fixture Consult Code for details Fig 3a FINISHED WALL a CENTER LINE OF a FIXTURE SPUD A A B c B L 1 1 4 Bi FILE EDGES NG soo OLDER ADAPTER M965022 Rev 1 3 1 INSTALL FLUSH VALVE Fig 6a amp 6b 1 As shown in Fig 6a insert the side INLET FLANGE 1 on the FLUSH VALVE 2 into the SUPPLY STOP 8 Lubricate the INLET FLANGE O RING 4 with water if necessary Lightly tighten COUPLING NUT 5 Fig 6a Important Do not use lubricants other than water or any type of thread sealing paste or tape 2 Align the FLUSH VALVE 2 Fig 6b directly above the DOWN TUBE 7 and VACUUM BREAKER COUPLING NUT 6 Make sure that GASKET 10 is in
6. stalled Note There is a 13mm 4 2 tolerance for the 121mm 4 3 4 dimension Fig 6b 3 Pull the DOWN TUBE 7 up to meet the threaded ee FLUSH VALVE CONNECTION 8 and hand tighten 4 3 4 1 2 the VACUUM BREAKER COUPLING NUT 6 Align all JE components of the flush valve assembly Fig 6b 4 Lightly tighten the COUPLING NUT 5 connection first then the VACUUM BREAKER COUPLING NUT 6 and finally the SPUD COUPLING NUT 9 Once alligned correctly use a wrench to tighten couplings to make water tight connections Fig 6b H FLUSH OUT SUPPLY LINES Fig 7 1 Remove COVER 1 from SUPPLY STOP 2 Make sure supply stop is closed 2 Remove FLUSH VALVE CAP 3 Pull out PISTON 4 Replace FLUSH VALVE CAP 3 and tighten 2 With a flat blade screwdriver open SUPPLY STOP 2 to flush line of any debris or sediment 4 Close SUPPLY STOP 2 Remove FLUSH VALVE ne OPENS CONTROL STOP CAP 3 Replace PISTON 4 Replace FLUSH VALVE hn oS 2 F N CAP 3 and tighten i pe CN CU D A lt gt REMOVE COVER CLOCKWISE eae CLOSES CONTROL STOP lz af 1 4 M965022 Rev 1 3 ADJUST SUPPLY STOP Fig 8 IMPORTANT To avoid overflowing the SUPPLY STOP 3 must never be opened to the point where the flow from the valve exceeds the flow capacity of the fixture The fixture and drain must be able to handle a continuous flow in case of a flush valve failure Valve is designed to provide stated flush volume wi
7. th a 25 GPM flow rate 1 Remove COVER 2 from SUPPLY STOP 3 Turn on water supply 1 4 turn to 1 2 turn CCW and test for leaks Note Unit may flush for approximately 5 to 10 sec when water is first turned on 2 Actuate the FLUSH VALVE by pulling handle down 3 Adjust SUPPLY STOP 3 after each flush until the stated flush volume is achieved no splashing occurs and the fixture is properly cleansed 4 When adjustment is complete replace COVER 2 and tighten to ensure vandal resistance HOW TO RETROFIT OUR VALVE Fig 9 Replaces Industry Standard Manual and Electronic Valves Note In most Retrofits the wall escutcheon supply stop cover tube and vacuum breaker do not have to be replaced If these items do need replacement they must be purchased separately or order the complete flush valve assembly from American Standard 1 Remove COVER 1 from SUPPLY STOP 2 if installed Fig 9 2 Turn water supply off Fig 9 3 Loosen SPUD COUPLING NUT 3 Unthread COUPLING NUT 4 and VACUUM BREAKER COUPLING NUT 5 Remove FLUSH VALVE 6 Fig 9a 4 Clean all threaded connections before installing the new flush valve Fig 9a 5 Refer to Sections 4 5 and 6 to complete the retrofit installation Fig 9b Ef LEFT OR RIGHT HAND Fig 10 INSTALLATION Fig 10 1 The FLUSH VALVE can be installed either as a right or left hand installation 2 Orientate the FLUSH VALVE as shown in Fig 10 to desired position
8. ustration below shows all items after they have been removed from the carton Some items may be packaged partially assembled to other items 1 Flush Valve Assembly 5 Sweat Solder Adapter 2 Down Tube and Vacuum Breaker 6 Cover Tube 3 Spud Coupling Nut and Washers 7 Wall Escutcheon 4 Spud Flange 8 Supply Stop 9 Installation Instructions CARE INSTRUCTIONS DO SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER DRY WITH A SOFT COTTON FLANNEL CLOTH DO NOT DO NOT CLEAN THE PRODUCT WITH SOAPS ACID POLISH ABRASIVES HARSH CLEANERS OR A CLOTH WITH A COARSE SURFACE MANUAL FLUSH VALVE Exposed Flushometer 6047 Series for 1 1 2 top spud Toilets 7017 Series FOR TOP SPUD APPLICATIONS CLOG RESISTANT e Self cleaning piston valve prevents clogging and reduces maintenance OPERATING PRESSURE Overall Range 20 125 psi Recommended 25 psi flowing 80 psi static FLOW REQUIREMENT 4 25gpm 94 6 L min i Flush valves include sweat solder kit Water pressure over 80 psi is not recommended with most plumbing fixtures u erican Standard Faucets visit our website at www americanstandard co er s e mail us at faucetsupport americanstandard com For Parts Service Warranty or other Assistance please call 1 800 442 1902 In Canada 1 800 387 0369 In Toronto Area only 1 905 3061093 M965022 Rev 1 3 Fig 1 Roughing in Dimensions FINISHED WALL 38mm 127mm 1 1 2 5 DN 25mm 08mm 133mm n

Download Pdf Manuals

image

Related Search

Related Contents

エコビジョン  Bedienungsanleitung Operating Instructions Notice d'emploi  Bandgenerator  Instructions / Assembly  FlexScan P1700 Bedienungsanleitung  ILOG CPLEX 9.0 Getting Started  OPERATING INSTRUCTIONS  Scarica la tua copia in pdf  APC Essential SA 5 GR Promo  Cisco Systems 15454 SDH Network Router User Manual  