Home
Monte Carlo Fan Company 5CZ52 User's Manual
Contents
1. the screw closest to the motor To adjust a blade tip up insert washer not supplied between the blade and blade holder at the two screws far thest from the motor Reverse the position of the washer if blades mount from top of blade 6 1f blade wobble is still noticeable interchanging two adjacent side by side blades can redis tribute the weight and possibly result in smoother operation Figure 1 Blade Brackets Figure 2 4 If light does not work 1 Check wire from fan to make sure it is connected to hot wire from house 2 Check for loose or disconnected wires in fan switch housing 3 Check for loose or disconnected wires in light kit 4 Check for faulty light bulbs CAUTION Make sure main power is turned off before entering switch housing MONTE CARLO Customer Service Center 740 S W Loop 820 Suite 110 Fort Worth Texas 76115 1 800 519 4092
2. Owner s Ceiling Fan Installation Instructions Total fan weight For 5CZ52 Series Fans READ AND SAVE THESE INSTRUCTIONS MONTE CARLO o Quality Ceiling fans LISTED Installation SAFETY TIPS WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING READ AND SAVE THESE INSTRUCTIONS Installation work and electrical wiring must be done by qualified person s in accordance with applicable codes and standards ANSI NFPA 70 1999 including fire rated construction Use this unit only in the manner intended by the manufacturer If you have any questions contact the manufacturer After making the wire connections the wires should be spread apart with the grounded conductor and the equipment grounding conductor on one side of the outlet box and ungrounded conductor on the other side of the outlet box Before you begin installing the fan Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Be cautious read all instructions and safety information before installing your new fan Review the accompanying assembly diagrams When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Make sure the installation site you choose allows the fan blades to rot
3. Standard wiring opti ion House Fan Black W gt _ Black 77 Blue White Attach blue wire only if attaching 4 light kit with fan White Green Downrod 1 AXXXXI Green Bracket Secure with twist lock wire connectors included For pullchain controls follow diagram above Make sure that all exposed wiring is secured inside wire nuts Note Wires from house may vary in color and may not include ground wire After wiring is conplete gently push wires into junction box with wire nuts pointing upward Refer to point 3 of safety tips Wiring option with wall speed control Fan Switch Control For control of fan and optional light from wall location follow diagram above NOTE A professional electrician is recom mended for this type of installation Raise the canopy up and align the two holes in the canopy with the two holes in the hanger bracket Secure with two 5 32 x 1 2 screws provided Fiber washers Combo Blades feature two high quality finishes on one blade Select the one that best comple ments your decor or change the style with just a flip of the blade Remove plastic shipping stabilizer tabs from motor if present The screws washers and motor pads are pre installed to the blade hold ers Attach blade assembly to motor by tighten ing first screw one turn then tighten second screw securely Then go back and tighten first screw securely To gain access to the bla
4. ate without any obstructions Allow a minimum clearance of 7 feet from the floor to the trailing edge of the blade To reduce the risk of fire electric shock or personal injury mount to outlet box or supporting system acceptable for fan support Mounting must support at least 35 Ibs Do not bend blade holders during installation to motor balancing or during cleaning Do not insert foreign object between rotating blades Attach the mounting bracket using only the hardware supplied with the outlet box To reduce the risk of fire or electric shock do not use this fan with any solid state fan speed control device or variable speed control If this unit is to be installed over a tub or shower it must be marked as appropriate for the application NEVER place a switch where it can be reached from a tub or shower The combustion airflow needed for safe operation of fuel burning equipment may be affected by this unit s operation Follow the heating equip ment manufacturer s guideline safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities Before servicing or cleaning unit Switch power off at Service panel and lock service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device su
5. ch as a tag to the service panel TOOLS REQUIRED Phillips Screwdriver Wire Cutters Pliers Step Ladder Before you begin installing the fan Switch power off Before installing this fan make sure the outlet at Service panel and lock service disconnecting means 0x is properly installed to the house structure Unpack and inspect fan carefully to be certain all contents are included See exploded view parts lists Install mounting brackets to outlet box in ceiling using the screws and washers provided with the outlet box to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Feed motor lead wires through downrod canopy assembly and insert downrod into motor yoke Next insert clevis pin through yoke and down rod and secure with cotter pin see Inset Tighen both yoke set screws to further secure downrod system acceptable for fan support Mounting must support at least 35 Ibs Carefully lift fan assembly onto mounting bracket Rotate fan so that the notch on the ball engages the ridge in the mount ing bracket This will allow hands free wiring CANADIAN MOUNTING SYSTEM INSERT Cotter Pin Mounting Bracket Feed motor lead wires through downrod canopy assembly and insert downrod into motor yoke Next insert clevis pin through yoke and down z 7 7 ro
6. crews which attach the fan blade holder to the motor are tight 3 Check to make sure wire nut connectors in switch housing are not rattling against each other or against the interior wall of the switch housing CAUTION Make sure main power is turned off before entering switch housing 4 Some fan motors are sensitive to signals from Solid State variable speed controls DO NOT USE a Solid State variable speed control 5 Allow break in period of 24 hours Most noises associated with a new fan will disappear after this period 3 If fan wobbles 1 Make sure that the ridge of the canopy engages the notch in the downrod ball 2 Check that all blades are screwed firmly into blade holders 3 Check that all blade holders are tightened securely to motor Touching 4 Make sure that canopy and mounting bracket are tightened securely to ceiling junction box Ceiling and junction box is mounted firmly to ceiling joist 5 Most fan wobble problems are caused when blade levels are unequal Check this level by selecting a point on the ceiling above the tip of one of the blades Measure this distance from blade tip to ceilng Keeping measure within 1 8 rotate the fan until the next blade is posi tioned for measurement Repeat for each blade If all blade levels are not equal you can adjust BladeTipDown T T blade levels by the following procedure To adjust a blade tip down insert a washer not sup Faniblede a R plied between the blade and blade holder at
7. d and secure with cotter pin see Inset While the fan assembly is still on the Tighen both yoke set screws to further secure ground thread the safety cable downrod through the mounting bracket Ridge N li l Ball age Notch hai plain washer safety cable Lift fan assembly and install the safety cable directly to the building structure using the 3 lag screw and plain washer provided Before proceeding to the the next step make sure that the cable is properly installed and will support the fan weight Make sure the screw washer and safety cable are installed using the order pictured above Carefully lift fan assembly onto mounting brack et Rotate fan so that the notch on the ball Install mounting brackets to outlet box engages the ridge in the mounting bracket This in ceiling using the screws and wash will allow hands free wiring For wiring instruc ers provided with the outlet box tions please refer to page 4 step 7 CANADI AN SAFETY TIPS WARNI NG MOUNT ONLY TO AN OUTLET BOX MARKED ACCEPTABLE FOR FAN SUPPORT All set screws must be checked and retightened where necessary before installation Installation Note After installation please refer to operation maintenance and troubleshooting sections in this manual If your fan is packaged with a light kit or if you wish to install a separately purchased light kit please refer to the insert sheet titled Light Kit Installation
8. de bracket attachment holes remove the switch housing cover by unscrewing the three screws Gently slide the cover off After attaching blade reinstall the switch housing using the three screws previously removed Trouble Shooting If you have difficulty operating your new ceiling fan it may be the result of incorrect assembly installation or wiring In some cases these installation errors may be mistaken for defects If you experience any faults please check this Trouble Shooting Chart If a problem cannot be remedied or you are experiencing difficulty in installation please call our Customer Service Center at the number printed on your parts list insert sheet Warning Before servicing or cleaning unit Switch power off at Service panel and lock service dis connecting means to prevent power from being switched on accidentally When the service dis connecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel TROUBLE SUGGESTED REMEDY 1 If fan does not start 1 Check main and branch circuit fuses or circuit breakers 2 Check line wire connections to fan and switch wire connections in switch housing 3 Check to make sure the dip switches from the transmitter and receiver are set on the same frequency CAUTION Make sure main power is turned off 2 If fan sounds noisy 1 Check to make sure all screws in motor housing are snug not over tightened 2 Check to make sure the s
Download Pdf Manuals
Related Search
Related Contents
KDV-MP6032U Behringer E1220 User's Manual 平成24年度 レーザ機器の安全・安心に関する 調査研究報告書 Product Description — Tobii Glasses 2 Guía del usuario - Sena Technologies, Inc. Mode d`emploi Gants exfoliants Philips AVENT Newborn Starter Set SCD270/60 Sony DCR-PC109 Notes RBC Installation Manual MT1389GH - Manuales de Service Copyright © All rights reserved.
Failed to retrieve file