1. V sync at TTL levels 2 Composite ve sync at TTL levels 3 Sync on green an extra 0 3V ve on the 0 7V 75 Ohm Green video signal 4 4 SDI Input Format Serial video data in SMPTE 270Mb s format Input impedance 75 ohms 4 5 DVI Input DVI input is via a Molex 88741 series or similar Signals which are in LVDS form are input via 100 ohm differential lines using TMDS coding Maximum pixel clock rate is 165MHz so that the maximum transition rate on the colour signals may exceed 1 5GHz Issue 4 03 27 03 03 Calibre UK Ltd 2003 Page 9 0 CALIBRE 4 6 Component Video Input This may be RGB sync YUV sync RGB with sync on green or YUV with sync on Y The unit will automatically search first for 4 wire separate sync then for 3 wire sync on green or sync on Y Issue 4 03 27 03 03 OCalibre UK Ltd 2003 Page 10 ABBREVIATIONS This section expands abbreviations peculiar to video applications which may be used in this manual Signal name mnemonics are not included CVBS DVI LVDS NTSC PAL RGB SDI SECAM SMPTE SVGA SXGA TMDS UXGA VGA XGA YIC Issue 4 03 Composite Video Baseband Signal alternatively Chroma Video Blanking and Sync Digital Visual Interface Low voltage differential signalling National Television Systems Committee USA Canada Japan TV standard Phase Alternating Line TV standard for UK and many other countries Red Green Blue analogue video Serial Digital Interface Systeme Electr
2. Menu This selection offers several options the availability of these functions is dependant on the particular build configuration and the signal input 1 Image flip Horizontal This is available on the majority of options and allows the user to flip the output image horizontally 2 Image Flip Vertical This can only be used if the Frame Store option is fitted and the input signal resolution is either video or computer graphics SVGA or lower 3 Text Enhanced Normal This text enhancement option can improve the appearance of fine text from a computer generated analog input signal Please note this function will only be effective if the signal resolution is close to the resolution of the panel no harm will be done to the unit by trying the enhanced and normal text options for other input resolutions 27 03 03 Calibre UK Ltd 2003 Page 6 Issue 4 03 27 03 03 Calibre UK Ltd 2003 Page 7 ENVIRONMENTAL AND SAFETY 3 1 Operating Temperature 0 C to 50 C Humidity non condensing 0 to 95 3 2 Storage Temperature 250C to 85 C Humidity non condensing 0 to 95 3 3 Safety Issues The display interface and keyboard are low voltage devices which do not generate any hazardous voltages However when designing an installation bear the following points in mind Any mains operated power supply should comply with safety and EMC legislation in the country of operation Any mains wiring should comply with the safety stan
3. l f l DVI f f l l SATELLITE RECEIVER SCART to CVBS connector cws i i i l Y C S video f i f I f l Component video i f l f l SDI i VIDEO k pin mini din connec tor l 1 CAMERA Power Input 1 1 l f f l rte SCART to 18 way pla 1 KEYPAD header connector or A l SCART to LoPP BNC POWER SUPPLY BROADCAST STUDIO EQUIPMENT EDS EE 12Y Nominal See spec for current requirement Installation Example 1 2 Product Overview The monitor is designed to accept the following input signals e Composite video via BNC socket or 3 pin header e S Video via 4 way mini_DIN socket e RGB and YUV component video via 10 pin header on open chassis units or 4 off BNC sockets on cased units e SDI Serial Digital Interface via 3 pin header on open chassis units or a BNC sockets on cased units e RGB analogue computer interface via 15 way HDD socket or 10 pin header e DVI Digital Visual Interface via DVI socket Molex 88741 series or similar These signals can be all displayed on the panel and ALL signals are displayed FULL SCREEN Near optical quality scaling means that the output signal is scaled with minimal loss of quality or image resolution irrespective of the resolution of the incoming signal Issue 4 03 27 03 03 OCalibre UK Ltd 2003 Page 1 Factory defaults have been carefully chosen such that most users will not need to make any adjustments A simple user interface sup
4. tinge clean white or to a red tinge warm white Issue 4 03 27 03 03 Calibre UK Ltd 2003 Page 5 2 4 5 2 4 6 Issue 4 03 0 CALIBRE The System Menu This selection contains functions which are more applicable to system operation than to picture adjustment 1 Esc The Esc option returns to the last saved setup It is useful if an adjustment has been made in error After an Esc the menu is removed 2 Save The Save option saves all the user adjustments for the displayed signal type The new adjustments are stored in non volatile memory and so are still valid from a power down power up cycle After a Save the menu is removed 3 Reset The are two types of Reset option Selecting Reset from the menu restores the user adjustable parameters for the signal currently being display back to the factory defaults Simultaneously pressing four buttons Br Br Con Con restores to factory default state all the user adjustments for the signal currently being displayed This is useful if a picture set up has become hopelessly lost or confused The Reset option can also be accessed even if the OSD has been lost After a Reset the menu is removed 4 OSD Timeout This selection enables the user to control the time after which the OSD display is cancelled It can be adjusted in 15 sec increments from 1 15 sec to 4 1 min approximately 5 OSD X and OSD Y These functions control the position of the OSD display on the scr
5. user to configure the preferred input selections If a facility is not fitted it will be displayed but not selectable By pressing the Br Con and Br Con keys the following choices can be made 1 Signal type priority Video graphics or Graphics video 2 Video priority search order CVBS Y C SDI Component Y C CVBS SDI Component SDI Component CVBS Y C Component SDI CVBS Y C 3 Graphics search RGB DVI or DVI RGB 4 Component video type RGB or YUV Incorrect colours may be due to wrong selection here NOTE you can only select those inputs which your monitor is configured for 2 4 4 The Colour Menu 1 Video Inputs The contrast video gain and brightness black level parameters also colour saturation for PAL NTSC and SECAM inputs can be accessed from this menu For NTSC signals there is an additional HUE option 2 Computer Inputs Individual Colour Adjustments Red green and blue levels can be thought of as individual brightness controls for each of red green and blue They should be adjusted for the desired colour balance and to minimise noise on low intensity colours and greys Colour tints can be added as required Gains can be thought of as individual contrast controls for each of red green and blue They should be adjusted for the desired colour balance and lack of noise on high intensity colours and whites For example a block of white can be changed to a blue
6. CALIBRE Cornwall House Cornwall Terrace Bradford West Yorkshire BD8 7JS UK Telephone 01274 394125 Fax 01274 730960 E mail sales calibreuk com Premier View 4 Monitor Operating Manual Issue 4 03 27 03 03 Calibre UK Ltd 2003 CALIBRE ET Welcome to the Calibre LCD monitor Operating Manual If you have any queries relating to this or any other product supplied by Calibre please visit our web site www calibreuk com For support or further information please contact a sales representative at Cornwall House Cornwall Terrace Bradford BD8 7JS UK Tel 44 0 1274 394125 Fax 44 0 1274 730 960 E mail sales calibreuk com Web site www calibreuk com All World wide Rights Reserved Issue 4 03 27 03 03 All trade marks acknowledged Calibre operates a policy of continued product improvement therefore specifications are subject to change without notice as products are updated or revised E amp OE Issue 4 03 27 03 03 Calibre UK Ltd 2003 Page i CONTENTS COMO S oar rd isa ji PRODUCT DESCRIPTION accion idos ridad Paa EEA area net lire 1 1 1 IMMFODUGHON imitan did ne Minnie rte trie ft OENE 1 1 2 Product Over UoN cedidas de 1 OPERATION riin a a dante anv ee i Pan ee a de Pa eee 3 2 1 Normal Op ration siaina eaae a dee tees eld da teens 3 2 2 User Interface Button einen 3 2 3 User ControlS sm ai rss Dirt te re 4 2 4 OSD Meu e o a dase woh o dd re Le e del 4 ENVIRONMENTAL AND SAFETY aafe
7. a a a A a Nia 8 3 1 perai ae e tech cece N a eet seca A A EE 8 3 2 SOA e E e en et en ee 8 3 3 Safety ISSUES unid dd da nan ta dre 8 PRODUCT SPECIFICATION smile Ann at ened 9 4 1 INTRODUCTION Aas ee alee ee Ge ee cee Nae ee Nees ae ee Aad 9 4 2 Video INpUtSE a a ade ee ee A re eae ie eee EE 9 4 3 Computer RGB and DVI Inputs ss 9 4 4 SDI M UT 28e ccc dates aa av ed snc tee can ehh aa Ton a nr aa Ad ante eats gd setae 9 4 5 DVl Input sus Ste e call A ne errr eer rer steerer ree res 9 4 6 Component Vid o Input 2 444588 hausses su Rte tnt Ameli dut nie 10 ABBREVIATIONS 5 ee i Pre ee eed eee ieee 11 Issue 4 03 27 03 03 Calibre UK Ltd 2003 Page ii PRODUCT DESCRIPTION 1 1 Introduction This manual is intended to give an operator information to facilitate connection setting up and usage of the monitor which is fitted with a PremierView 4 flat panel driver card Its technical content is limited to that which is relevant to these functions full technical information is given in the Technical Manual The figure below details all the possible input connections please check your monitor or product description to determine which inputs are fitted dex CARO Standard video OUTPUT 15 way HDD connector DVI CARD DVI D connec tr Lo p OUTPUT e9 Molex 8871 serles PREMVIEW amp I DISPLAY l f l VGA Analog 1 I f
8. ble is full further stored settings will over write the earliest so that the settings complement contains the latest 25 1 Edge Adjustment Picture Size and Position Controls The four Edge controls shift each edge within available limits Note that the maximum available shift depends on the incoming video standard and the display panel type and may be restricted vertically This provides very flexible and easy to use image size and position control 2 Moire correction The user can choose from one of four correction tables 3 Clock Analogue Graphics only This sets the total number of input pixels per line to correspond with the input source and will normally require adjustment only for unusual signals 4 Phase Analogue Graphics only This adjusts the internal clock to sample each pixel as near as possible to the centre Phase will normally require adjustment for unusual types of signal 27 03 03 Calibre UK Ltd 2003 Page 4 CALIBRE CALIBRE 5 Aspect Ratio Video signals only for SXGA panels This allows a user to select the displayed aspect ratio where the signal input is at variance with the display panel s natural aspect ratio The format may be adjusted to either Letter Box 4 3 LB or Overscan 4 3 OS Letter Box effectively adjusts the height of the displayed image and Overscan effectively adjusts the width to achieve the desired 4 3 aspect ratio 2 4 3 Input Select This allows the
9. dards applicable in the country of operation The backlight inverter in most display panels generates potentially lethal voltages Ensure that the installation offers adequate protection to the operator from this hazard Issue 4 03 27 03 03 Calibre UK Ltd 2003 Page 8 PRODUCT SPECIFICATION 4 1 Introduction This section provides technical details for all possible inputs please refer to the model specification to determine which inputs can be displayed by the monitor 4 6 Power Supply Requirement Unless otherwise specified on the product the supply voltage MUST be from a clean 12V 1 supply The power supply rating depends on the requirements of the display panel please refer to the model specification for details 4 2 Video Inputs Signal formats Composite CVBS S Video Y C SDI DVI Standards NTSC PAL SECAM Composite CVBS input level 1V p p nominal inc sync Luminance Y input level 1V p p nominal inc sync Chrominance C input level 0 6V p p nominal Input Impedance all inputs 75 Ohms 4 3 Computer RGB and DVI Inputs Signal formats DOS 720 x 400 70Hz VGA 640 x 480 50Hz to 75Hz inclusive MAC 640 x 480 67Hz SVGA 800 x 600 50Hz to 75Hz inclusive MAC II 832 x 624 74 7Hz XGA 1024 x 768 50Hz to 75Hz inclusive MAC 2 1152 x 870 75Hz SXGA 1152 x 900 50Hz to 75Hz inclusive SXGA 1280 x 1024 50Hz to 75Hz inclusive UXGA 1600 x 1200 60Hz RGB video level 0 7V 1 0V RGB input impedance 75 Ohms Sync formats 1 Separate H amp
10. een Its default setting is such as to place the OSD in the centre of the screen but the user can adjust its position with these functions 6 Auto Centering This is simply a Yes No selection If an input signal changes it is first measured and compared with stored selections If its parameters are already stored they are installed If they are not stored the Auto Centering selection is checked and if set to No the best fit is displayed The user can then centre the picture using OSD auto setup If Auto Centering is set to Yes centering is performed automatically which may take more than 15 seconds This could cause a problem if using Windows wherein a resolution change is displayed only for 15 seconds and reverts to its previous selection if no acknowledgement is entered For this reason the default state is No NOTE this control only configures Analogue Graphics inputs 7 Computer AV Mode This option is only available on units fitted with the professional decoder and is valid when the input is RGB S connected via the component input port or an interlace graphics signal is connected via the analog computer input port Computer Mode should be selected when the input comes from a computer generated source this option provides reduced flicker for predominantly static data AV Mode should be selected when the input comes from any source which contains moving images as it provides a smoother output The Miscellaneous
11. onique Couleur Avec Memoire TV broadcast standard used in France Middle East and most of Eastern Europe Society of Motion Picture Television Engineers Super VGA 800x600 pixels Super XGA 1280x1024 pixels Transition minimised differential signalling Ultra XGA 1600x1200 pixels Video graphics array 640x480 pixels Extended graphics array 1024x768 pixels Luminance Y and Chrominance C also called S video 27 03 03 Calibre UK Ltd 2003 Page 11
12. plied with On Screen Display allows the user to adjust a wide variety of parameters if necessary Once the parameters are set they can be stored in non volatile EEPROM which ensures the set up is retained when power to the unit is switched off Issue 4 03 27 03 03 Calibre UK Ltd 2003 Page 2 OPERATION 2 1 Normal Operation Normal operation of the interface consists of little more than connecting up the power supply video and computer signals and switching on Signals are scanned in accordance with the currently selected priority list and the highest priority valid signal is displayed If the priority or any other picture parameter needs adjustment then the following section describes the user interface VIDEO GRAPHICS Brightness Controls backlight intensity Contrast Controls video gain Geometry Image edge adjust size and Image edge adjust size and position Moire correction aspect position Moire correction clock ratio For SXGA choice of Full tune phase sharpness scan overscan or letter box aspect ratios Input Select RGB DVI CVBS Y C Component Video Colour Colour contrast black level hue Contrast black level R G B NTSC only gamma correction gains R G B levels gamma correction System ESC Save Reset OSD timeout OSD X Y position Auto Centering Auto Setup Not applicable Yes No analogue graphics only Miscellaneous Image flip horizontal Some models allow the user
13. to flip the image vertically NOTE for Graphics inputs SVGA is the maximum resolution which can be flipped vertically Function dependent Menu Options 2 2 User Interface Buttons The physical user control panel consists of five push buttons One of these is dedicated to invoking the OSD Menu while the other four are dual purpose as listed below e Menu invokes OSD or next function level equivalent to enter key on a PC e Cont Direct contrast increase also used to increment selected parameter e Con Direct contrast decrease also used to decrement selected parameter e BR Direct backlight increase also used to increment selected parameter e BR Direct backlight decrease also used to decrement selected parameter Issue 4 03 27 03 03 OCalibre UK Ltd 2003 Page 3 2 3 2 3 1 2 4 2 4 1 2 4 2 Issue 4 03 0 CALIBRE User Controls Direct Brightness Adjustment Pressing the Br or BR button controls the intensity of the backlight After adjustment the new Brightness value is displayed on the screen until the OSD timeout period expires see para 2 4 5 The new setting is then stored and the display returns to normal Direct Contrast Adjustment Pressing the Con or Con button controls the contrast video gain of the picture After adjustment the new contrast value is displayed on the screen until the OSD timeout period expires The new setting is then stored and the display returns to normal Men
14. u Select Pressing this button displays picture identification information together with a menu of icons To access lower level functions press Con Con Br or Br to toggle through the menus available for the currently displayed signal type then press MENU again to select that function The MENU button has a similar function to the ENTER key on a computer keyboard Exit from a menu is by selecting BACK which returns to the previous level When leaving the main menu you will be prompted to save any changes if you do not wish to save any changes select NO Note that Con and Br have identical functions in this mode as have Con and Br OSD Menu At the top of the menu is a line which identifies the type of signal currently displayed For computer signals the same section displays the signal resolution together with horizontal and vertical frequencies If its setup has been saved the user number of that signal is also displayed These figures are for guidance only Brightness and Contrast These perform the same functions as the direct button operations in para 2 3 1 and 2 3 2 above The Geometry Menu Geometry adjustments can be made for all types of input individually so that if the input type changes the geometry adjustment will change with it Saved settings include one each for PAL NTSC SECAM SDI and component video Additionally a total of 25 settings may be stored for analogue graphics RGB and DVI If this graphics ta