Home

Altronix MAXIMAL55D power distribution unit PDU

image

Contents

1. C contact Enclosure accommodates up to four 4 12AH batteries Maximal 55D weights approximate Product weight 39 8 lbs Shipping weight 43 8 Ibs UL 294 Agency Approvals UL Listed for Access Control System Units UL c CUL Listed CSA Standard C22 2 No 205 M1983 Signal Equipment A DEPAN en Eu f CAL FIRE D CSFM California State Fire Marshal Approved Enclosure Dimensions approximate 26 H x 19 W x 6 25 D 1 25 T 2 0 4 0 7 0 4 0 2 0 TOP 6 25 i5 41 25 0 85 8 90 8 40 L 0 85 5 usd H 1 50 En 5 0 8 50 o 7 50 o js TT TH IT t o 10 0 HL ILI I ul n dS p X T Lo To i i 0 85 8 90 8 40 0 95 r BOTTOM 6 25 4 0 2 0 L i 7 1 25 gis 22 Altronix Corp 140 58th Street Brooklyn NY 11220 718 567 8181 888 258 7669 altronix com
2. b Two 2 isolated power inputs external power supply is required current is determined by the power supply connected not to exceed a maximum of 10 amp total Sixteen 16 Access Control System trigger inputs Input options a Sixteen 16 normally open NO inputs b Sixteen 16 open collector inputs c Any combination of the above Sixteen 16 independently controlled outputs can be Fail Safe and or Fail Secure power outputs Sixteen 16 auxiliary power outputs unswitched outputs are rated 2 amp ACMSCB boards main fuse is rated at 10 amp Output PTC are rated 2 5 amp Red LEDs indicate outputs are triggered relays energized Fire Alarm disconnect latching or non latching is individually selectable for any or all of the sixteen 16 outputs Alarm output relay indicates that FACP input is triggered form C contact rated 1 amp 28VDC Green LED indicates FACP disconnect is triggered Filtered and electronically regulated outputs built inpower supply board s Built in charger for sealed lead acid or gel type batteries Maximum charge current 0 7 amp Automatic switch over to stand by battery when AC fails Zero voltage drop when unit switches over to battery backup AC failure condition Thermal and short circuit protection with auto reset AC input and DC output LED indicators AC fail supervision form C contact Low battery and battery presence supervision form
3. l Altronix Maximal55D Access Power Controller Rev DSMaximal55D F27K Overview This unit distributes and switches power to access control systems and accessories Unit converts a 115VAC 60Hz input into sixteen 16 independently controlled 12VDC Class 2 Rated PTC protected power limited outputs The outputs are activated by an open collector sink or normally open NO dry trigger input from an Access Control System Keypad Push Button REX PIR etc Units will route power to a variety of access control hardware devices including Mag Locks Electric Strikes Magnetic Door Holders etc Outputs will operate in both Fail Safe and or Fail Secure modes The FACP Interface enables Emergency Egress Alarm Moni toring or may be used to trigger other auxiliary devices The fire alarm disconnect feature is individually selectable for any or all of the sixteen 16 outputs All inter connecting equipment must be UL Listed Maximal55D Specifications 12VDC outputs Fire Alarm disconnect input options Maximum output current 12VDC 19 amp a Normally open NO or normally closed NC dry Option P S1 P S 2 contact input A I2VDC 9 5 amp 12VDC 9 5 amp b Polarity reversal input from FACP signaling circuit Class 2 Rated power limited outputs 115VAC 60Hz 6 0 amp input Input fuse rated 3 5 amp 250V Power supply input options a Two 2 common power input for either ACM8CB and lock power factory installed

Download Pdf Manuals

image

Related Search

Related Contents

ManualeTecnico WI-SA 1 6 - Pompe di calore, ecco le regole per  Samsung 2433BW Εγχειρίδιο χρήσης  TOP-LOADING HIGH EFFICIENCY LOW-WATER WASHER  Manual de Usuario  Samsung 19" 933HD LCD Monitor  Bedienungsanleitung  LIXADORA DE DISCO TG 125/E  sistema de controle de documentos avulsos - sisdoc  Descargar - Movistar    

Copyright © All rights reserved.
Failed to retrieve file