Home

Draper 136104 projection screen

image

Contents

1. page 2 If you encounter any difficulty installing or servicing your Salara call your dealer or Draper Inc Spiceland Indiana 765 987 7999 or fax 765 987 7142 IR Plug amp Play Salara by Draper Page 2 of 2 Dimensions Floating Mounting Brackets 5 16 iss i Case Length Fula ia Fie XS rO athe lt id t C _ _ iewing Surface 3146 Aahe 5 16 Wiring Diagram Standard 110 120V AC IEC no external wiring necessary Green Yellow Chassis ground label IEC Inlet 10 0N Ul OV Motor PCB Ground 1 10 Ring lt 2 Terminal on each ground wire www draperinc com DRAPER 765 987 7999
2. Installation Instructions IR Plug amp Play Salara by Draper Caution Read instructions through completely before proceeding Follow instructions carefully Installation contrary to instructions invali dates warranty Screen should be accessible for complete removal should fabric become damaged or should other service be required Screen should be installed level using a carpenter s level Nothing should be fastened to screen dowel or viewing surface Operating switch es packed separately in screen carton Do not discard with packing material Screen operates on 110 120V 60 Hz AC 1 1 amp current draw NOTE Screen has been thoroughly inspected and tested at factory and found to be operating properly prior to shipment Wall Ceiling Flush Mounting Attach Mounting Brackets to wall or ceiling see Fig 1 The installer should furnish screws toggle bolts molly bolts nylon or lead anchors as required by the mounting surface Installer also needs to ensure the mounting surface is reinforced sufficiently to support the screen Brackets must be level with each other Mounting Bracket Ceiling Mounting Bracket Figure 1 Plug the power cord included if ordered into the motor end of the screen case left end as the viewer sees the screen Attach the screen by snapping the extrusions on the back of the case onto the brackets With the lower edge of the screen case tilted away from th
3. e wall engage the rib on top of the case with the slot on each bracket Slide the screen case along the brackets to adjust the screen location from left to right if necessary see Fig 2 Once the case is in position pivot the case back toward the brackets until the lower edge of the case snaps into place with the spring loaded latch see Fig 3 Extrusions along back of case Figure 2 i 411 S Pearl St Spiceland IN 47385 USA I 765 987 7999 www draperinc com I fax 765 987 7142 Copyright 2007 Draper Inc Form Salara IRPlug amp Play_InstO7 R Printed in U S A 1 2 Figure 3 Electrical Connections Screen operates on 110 120V 60 hz AC 1 1 amp current draw Screen shipped with internal wiring complete Junction box is located inside left endcap and cover plate is secured to endcap with one screw Screen is shipped with internal wiring complete and control switch es fully boxed No external wiring is needed unless connecting to RS232 Plug cord into standard 110 120V AC outlet All operating switches should be OFF before power is connected Operation Screen is equipped with a handheld remote or 3 position operating switch see below Three positions up off down permit operation to be stopped at any point Factory adjusted limit switches automatically stop screen when fully down or fully up Wiring Control Options Plug amp Play Provided with built in IR receiver handheld IR remote control transm
4. itter and 10 3m IEC cordset No wiring necessary except to connect to RS232 Adjustments Screen has been factory set and should not normally require further adjustment If you desire to change the up and down stopping positions follow the procedures below There are two holes in the left end cap as seen from audience for both limit switch adjustments and neither is labled The hole closest to the audience is the up limit and the hole furthest from the audience is the down limit Down limit switch Down stopping position can be adjusted by turning knob furthest from audience with a screw driver or hex wrench Turning knob counterclockwise will allow viewing surface to run farther down Turning it clockwise will reduce the amount of exposed viewing surface Up limit switch You should never have to adjust this limit If you do however the Up stopping position can be adjusted by turning knob closest to audience with a screw driver or hex wrench through the small grommet Turning knob counterclockwise will allow surface to run farther into screen case Turning it clockwise will allow viewing surface to stop farther out of screen case CAUTION Be sure all switches are in off position before adjusting limit switches Always be prepared to shut screen off manually when new adjustment is being tested Screen may be severely damaged if viewing surface is allowed to run too far up or too far down Dimensional drawings on

Download Pdf Manuals

image

Related Search

Related Contents

user manual Ceramic glass hob  Centronic SunWindControl SWC441 - Becker  Acnodes Q5RF SERIES Heat Pump User Manual  Sans nom-2  PS-3600G Series User Manual - Pro  Troubleshooting Guide - Direct Windows and Doors  INTRODUCTION & USER MANUAL PROGRESSIVE L.D.      Hitachi Welder X200 User's Manual  

Copyright © All rights reserved.
Failed to retrieve file