Home
Siig PCI-2S+DOS
Contents
1. Push the board down firmly but gently until it is well seated Replace the slot bracket s holding screw to secure the card Replace the computer cover and reconnect the power cord Connect the 2 port fan out cable to the board s 25 pin connector See Figure 2 on page 3 for more details Driver Installation This section provides information on how to install the CyberSerial Dual PCI drivers DOS 1 2 Boot up DOS and insert the driver CD Copy OXSER EXE from the DOS folder to your C drive At the C prompt type in OXSER io 3e8 and the serial ports will be set up as COM3 and COM4 If your system already comes with 4 serial ports enabled type in OXSER io 220 instead and the ports will be set up as COM5 and COME Copy the OXSER command in step 3 into your autoexec bat and restart your system Windows 95 1 Atthe Update Device Driver Wizard click Next 2 Insert the driver CD click Other Locations 3 Typein D 9x click OK then click Finish Change D to match your CD ROM drive letter 4 From the Insert Disk window click OK When the Copying Files dialog box pops up type in D 9x then click OK 5 Restart Windows to complete the installation Windows 98 98SE At the Add New Hardware Wizard click Next Select Search for the best driver for your device Recommend then click Next 3 Insert the driver CD check Specify a location uncheck the other boxes type in D 9x then click Next Change D to
2. computer upgrade manufacturer of 1 Oconnectivity products including PCI amp ISA serial and parallel ports USB Serial ATA amp UltraATA controllers FireWire 1394a b Networking Sound Cards and other accessories SIIG is the premier one stop source of upgrades SIIG products offer comprehensive user manuals many user friendly features and are backed by an extensive manufacturer warranty High quality control standards are evident by the overall ease of installation and compatibility of our products as well as one of the lowest defective return rates in the industry SIIG products can be found in computer retail stores mail order catalogs and e commerce sites in the Americas and the UK as well as through major distributors system integrators and VARs PRODUCT NAME CyberSerial Dual PCI FCC RULES TESTED TO COMPLY WITH FCC PART 15 CLASS B OPERATING ENVIRONMENT FOR HOME OR OFFICE USE FCC COMPLIANCESTATEMENT This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation THE PARTY RESPONSIBLE FOR PRODUCT COMPLIANCE SHUG Inc 6078 Stewart Ave Fremont CA 94538 3152 CyberSerial Dual PCI is a trademark of SHG Inc SUG and SIG logo are registered trademarks of SIIG Inc Microsoft and Windows are reg
3. CyberSerial Dual PCI lt gt o Quick Installation Guide Introducing the CyberSerial Dual PCI The CyberSerial Dual PCI high speed serial I O card provides two additional 9 pin serial ports Depending on the model purchased this board will fit into either a Full or Low Profile chassis Features and Benefits Conforms to PCI v2 2 Plug and Play Reduces CPU load and improves system performance dramatically IRQ sharing feature reduces IRQ conflicts High speed serial port 9 pin works with 56K V 90 external modems ISDN terminal adapters PDAs digital cameras label printers and other serial port devices Built in FIFO buffers dramatically increase data transmit receive speed especially under Windows multitasking environment Each serial port can be configured for either 5V or 12V output for serial devices that require power System Requirements Pentium or equivalent computer with an available PCI slot DOS Windows 95 98 98SE ME NT 4 0 2000 XP Server 2003 Linux Kernel 2 4 x or later 04 0376A 1 Package Contents e CyberSerial Dual PCI board e 2 port fan out cable e Low profile bracket Dual Profile board only e DriverCD e Quick installation guide Layout Full profile bracket JP2 Serial port 2 my byl BE ii S 7 z Hi INSIG E Fa Fan out z CyberPro LS cable ee X connector 25 pin JP1 Serial port 1 Figure 1 Layout bracket size will be either Full or Lo
4. click Next 2 Select Search for a suitable driver for my device recommended then click Next 3 Check Specify a location uncheck the other boxes then click Next 4 Insert the driver CD type in D 2000 then click OK Change D to match your CD ROM drive letter 5 Click Next and Finish 6 Repeat steps 1 5 two more times 7 Restart Windows to complete the installation Windows XP 1 Atthe Found New Hardware Wizard select Install from a list or specific location Advanced then click Next 2 Insert the driver CD check Include this location in the search uncheck the other box type in D XP and click Next Change D to match your CD ROM drive letter 3 If the Hardware Installation window pops up click Continue Anyway then Finish Our driver has been tested for stability and compatibility 4 Repeat steps 1 3 three more times 5 Restart Windows to complete the installation Windows Server 2003 1 Atthe Found New Hardware Wizard select Install from a list or specific location Advanced then click Next 4 a Insert the driver CD check Include this location in the search uncheck the other box type in D 2003 thenclick Next Change D to match your CD ROM drive letter If the Hardware Installation window pops up click Continue Anyway then Finish Our driver has been tested for stability and compatibility Repeat steps 1 3 three more times Restart Windows to complete the installation To V
5. erify Windows 2000 XP 2003 Installation l Right click My Computer click Manage then click Device Manager Click on the plus sign in front of Ports COM amp LPT CyberSerial PCI 16Cxxx should be displayed two times Double click Multifunction adapters SIIG CyberPro 2S PCI board should be displayed Linux Kernel 2 4 x or later Open the terminal Type setserial bg dev ttyS and hit lt enter gt to show the current serial ports installed SIIG board will be set up at the next available address For example if your system comes with dev ttyS0 and dev ttyS1 set up SIIG board as dev tty2 and dev ttyS3 Type Ispci v and hit lt enter gt This command displays the CyberSerial Dual PCI s information similar to the example listed below This information is needed to configure the serial ports 02 0b 0 Serial controller Oxford Semiconductor Ltd EXSYS EX 41092 Dual 16950 Serial Subsystem SHG Inc Flags medium devsel IRQ 9 I O ports at a000 size 32 Memory at ed800000 32 bit I O ports at 9800 size 32 Memory at ed000000 32 bit Capabilities 40 Power Management Edit the startup file and add these two command lines at end of the startup file setserial dev ttyS2 port 0xa000 irq 9 uart 16950 setserial dev ttyS3 port 0xa008 irq 9 uart 16950 Note ttyS value I O port address and irq should be different from one system to another These va
6. ffered by SHG Inc Please see SIIG website for more warranty details If you should happen to encounter any problems with this product please follow the procedures below If it is within the store s return policy period please return the product to the store where you purchased from If your purchase has passed the store s return policy period please follow these steps to have the product repaired or replaced Step 1 Submit your RMA request Go to www siig com click Support then RMA to submit a request to SIG RMA If the product is determined to be defective an RMA number will be issued SIIG RMA department can also be reached at 510 413 5333 Step 2 After obtaining an RMA number ship the product e Properly pack the product for shipping All software cable s and any other accessories that came with the original package must be included e Clearly write your RMA number on the top of the returned package SIG will refuse to accept any shipping package and will not be responsible for a product returned without an RMA number posted on the outside of the shipping carton e Youare responsible for the cost of shipping the product to SIIG at the following address SIIG Inc 6078 Stewart Avenue Fremont CA 94538 RMA e SIIG will ship the repaired or replaced product via Ground in the U S and International Economy outside of the U S at no cost to the customer 11 About SIIG Inc Founded in1985 SIIG Inc isa leading
7. istered trademarks of MicrosoftCorporation Pentiumisa registered trademark of Intel Corporation Other names used in publication are for identification only and may be trademarks of theirrespective companies June 2005 Copyright 2005 by SIIG Inc All rights reserved
8. lues should be based on the results you get from steps 2 amp 3 Save the startup file and restart your system Changing COM Port Address Some serial devices need a specific COM port in order to work If your serial device works properly do not change this setting Windows 95 98 98SE ME 1 From the Device Manager window double click Ports COM amp LPT then double click the CyberSerial PCI serial port you want to change Click Settings tab click the down arrow that is next to the Port Name box and select a COM address that is not currently in use Click OK then close Device Manager to save the changes Windows 2000 XP Server 2003 1 From the Device Manager window double click Ports COM amp LPT then double click the CyberSerial PCI serial port you want to change Click Settings tab and click Advanced Click the down arrow that is next to the COM Port number box and selecta COM port thatis notin use Click OK Click OK then close Device Manager to save the changes Technical Support and Warranty QUESTIONS SIIG s Online Support has answers Simply visit our website at www siig com and click on Support Our online support database is updated daily with new drivers and solutions Answers to your questions could be just a few clicks away Youcanalso submit questions online and one of our technical support analysts will promptly respond A lifetime manufacturer warranty supplied with this product is o
9. match your CD ROM drive letter 4 Click Next then Finish 5 Repeat steps 1 4 6 Restart Windows to complete the installation Windows ME 1 Atthe Add New Hardware Wizard select Specify the location of the driver Advanced then click Next 2 Insert the driver CD check Specify a location uncheck the other box type in D ME then click Next Change D to match your CD ROM drive letter 3 Click Next then Finish 4 a 6 Repeat steps 1 and 2 Click Next Next then Finish Restart Windows to complete the installation To Verify Windows 95 98 98SE ME Installation 1 Right click My Computer click Properties then click Device Manager Double click Ports COM amp LPT CyberSerial PCI 16Cxxx should be displayed two times Double click Multi function adapters SIIG CyberPro 2S PCI board and PCI Function should be displayed Windows NT 4 0 N oS gi e p From the desktop click Start then Run Insert the driver CD type in D NT4 Install_serial exe then click OK Change D to match your CD ROM drive letter Click Next when the Welcome window appears Select Install then click Next Click Yes then click Exit Restart Windows to complete the installation To Verify Windows NT 4 0 Installation 1 Click Start Settings Control Panel Double click Ports device icon Two new COM ports will be assigned when successfully installed Windows 2000 1 At the Found New Hardware Wizard
10. w profile Jumper Settings JP1 JP2 Open 0 volts default Short 1 2 5V Short 2 3 12V Note Mostserial devices donotrequire additional power through the serial port Refer to your serial device s manual for more information Fan out Cable 9 pin serial 25 pin connector 9 pin serial Figure 2 Fan out cable Hardware Installation General instructions for installing the card are provided below Since the design of computer cases and motherboards vary refer to your computer s reference manual for further information if needed Static Electricity Discharge may permanently damage your system Discharge any static electricity build up in your body by touching your computer s case for a few seconds Avoid any contact with internal parts and handle cards only by their external edges 1 Turn OFF the power to your computer and any other connected peripheral devices 2 Unplug the power cord from the back of the computer 3 Remove your computer s cover 4 Remove the slot bracket from an available PCI slot Change JP1 and JP2 jumper settings to the desired voltage only if your serial device needs additional power from the serial port However most serial devices do not require additional power For more information see Figure 1 on page 2 The jumpers can be removed if power output is not required To install the card carefully align the card s bus connector with the selected PCI slot on the motherboard
Download Pdf Manuals
Related Search
Related Contents
Dell OptiPlex 3010 - Factor de forma pequeno Manual do Proprietário My Document Site Internet Conserver ce manuel d`utilisation GUÍA AVANZADA DEL USUARIO PosiTector®DPM - DeFelsko Corporation iconBIT PSS990 BT Handleiding LG WT1701CV washing machine BT Edge 1500 User Guide Copyright © All rights reserved.