1. GP Intelligent Line Interactive UPS Systems 100 110 120V Sine Wave Input Output 2200VA Extended Run Model SMART2200RMXL2U Not suitable for mobile applications mas 9 CTH 7 Espanol Francais TRIPP LITE POWER PROTECTION 1111 W 35th Street Chicago IL 60609 USA Customer Support 773 869 1234 www tripplite com Copyright 2006 Tripp Lite All rights reserved SmartPro is a registered trademark of Tripp Lite Warranty Registration 11 Battery Replacement 12 13 25 Important Safety Instructions VAN SAVE THESE INSTRUCTIONS This manual contains important instructions that should be followed during the installation operation and storage of all Tripp Lite UPS Systems Failure to heed these warnings will void your warranty UPS Location Warnings Use caution when lifting UPS Because of the considerable weight of all Rackmount UPS systems at least two people should assist in lifting and installing them nstall your UPS indoors away from excess moisture or heat dust or direct sunlight For best performance the ambient temperature near your UPS should be between 0 C and 40 C between 32 F and 104 F Leave adequate space around all sides of the UPS for proper ventilation Do not obstruct its vents or fan openings UPS Connection Warnings The UPS contains its own energy source battery The output terminals may be live even when the UPS is not connected to a
2. correct the interference at his own expense The user must use shielded cables and connectors with this product Any changes or modifications to this product not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment Regulatory Compliance Identification Numbers For the purpose of regulatory compliance certifications and identification your Tripp Lite product has been assigned a unique series number The series number can be found on the product name plate label along with all required approval markings and information When requesting compliance information for this product always refer to the series number The series number should not be confused with the marking name or model number of the product Tripp Lite has a policy of continuous improvement Product specifications are subject to change without notice Note on Labeling Two symbols are used on the label V AC Voltage V DC Voltage TRIPP LITE 1111 W 35th Street Chicago IL 60609 USA 773 869 1234 USA 773 869 1212 International www tripplite com 200607114 93 2586_EN
3. wall outlet The UPS will be completely OFF Afier you plug the UPS into a live AC outlet the UPS in Standby mode will automatically charge its batteries but will not supply power to its outlets until it is turned ON The alarm will beep once briefly afier the indicated interval has passed If fully charged MUTE TEST Button To Silence or Mute UPS Alarms briefly press and release the MUTE TEST button To Run a Self Test with your UPS plugged in and turned ON press and hold the MUTE TEST button Continue holding the button until the alarm beeps sev eral times and the UPS performs a self test See Results of a Self Test below Note you can leave connected equipment on during a self test Your UPS how ever will not perform a self test if the UPS is not turned on see ON OFF STANDB Y Button description CAUTION Do not unplug your UPS to test its batteries This will remove safe electrical grounding and may introduce a damaging surge into your network connections Results of a Self Test The test will last approximately 10 seconds as the UPS switches to battery to test its load capacity and battery charge If the OUTPUT LOAD LEVEL LED remains lit red and the alarm contin ues to sound after the test the UPS s outlets are overloaded To clear the over load unplug some of your equipment and run the self test repeatedly until the OUTPUT LOAD LEVEL LED is no longer lit red and the alarm is n
4. S bat teries will gradually deplete over time it is recommended that you periodically perform a self test see MUTE TEST Button description to determine the energy level of your UPS batteries BEFORE a blackout or severe brownout occurs During a prolonged blackout or severe brownout you should save files and shut down your equipment since battery power will eventually be depleted When the LED turns red and an alarm sounds continuously it indicates the UPS s batteries are nearly out of power and UPS shut down is imminent BATTERY WARNING LED this LED lights red and an alarm sounds intermittently after you initiate a self test See MUTE TEST Button description to indicate the UPS batteries need to be recharged or replaced Allow the UPS to recharge continuously for 12 hours and repeat the self test If the LED con tinues to light contact Tripp Lite for service If your UPS requires battery replacement visit www tripplite com to locate the specific Tripp Lite replace ment battery for your UPS Basic Operation continued Other UPS Features Rear Panel HI Q 15 amp 120V NEMA 5 15R M 20 amp 120V NEMA 5 20R VOLTAGE SELECT RATE 120V 10V 100V 120v AC Receptacles Your UPS features 15 and 20 amp AC outlets These output receptacles provide your connected equipment with AC lin
5. check that the UPS System s circuit breaker s are not tripped This is the most common cause of service inquiries which can be easily remedied by following the resetting instructions in this manual 2 If the problem continues do not contact or return the UPS to the dealer Instead call Tripp Lite at 773 869 1233 A service technician will ask for the UPS s model number serial number and purchase date and will attempt to correct the problem over the phone 3 If the problem requires service the technician will issue you a Returned Material Authorization RMA number which is required for service If you require packaging the technician can arrange to send you proper packaging Securely pack the UPS to avoid damage during shipping Do not use Styrofoam beads for packaging Any damages direct indirect special incidental or consequential to the UPS incurred during shipment to Tripp Lite or an authorized Tripp Lite service center is not covered under warranty UPS Systems shipped to Tripp Lite or an authorized Tripp Lite service center must have transportation charges prepaid Mark the RMA number on the outside of the package If the UPS System is within the 2 year warranty period enclose a copy of your sales receipt Return the UPS for service using an insured carrier to the address given to you by the Tripp Lite service technician Warranty Registration Visit www tripplite com warranty today to register the warranty for your new Tripp Lit
6. ding sine wave power from its battery reserves for as long as the distortion is present In areas with poor utility power or where the UPS s input power comes from a backup generator chronic waveform distortion could cause the UPS to switch to battery too frequently draining its battery reserves You may be able to reduce how often your UPS switches to battery due to mod erate waveform distortion by experimenting with different settings for this dial As the dial is turned clockwise the UPS becomes more tolerant of variations in its input power s AC waveform NOTE The further the dial is adjusted clockwise the greater the degree of waveform distortion the UPS will allow to pass to con nected equipment When experimenting with different settings for this dial operate connected equipment in a safe test mode so that the effect on the equip ment of any waveform distortions in the UPS s output can be evaluated without disrupting critical operations External Battery Connector Use to connect Tripp Lite external battery packs for additional runtime Refer to instructions available with the battery pack for complete connection information and safety warnings Battery Charge Level Switches Controls the UPS system s battery charge rate If you connect any external batteries set the Battery Charge Level Switches to the down position This will increase your UPS s charger output so the addition al batteries charge faster CAUTION DO NOT set th
7. e Battery Charge Level Switches to the down position without an external battery connected There is a risk of damaging the UPS s internal battery system Input Breaker Protect your electrical circuit from overcurrent draw from the UPS load If these breakers trip remove some of the load then reset them by pressing the breaker s in Ground Screw Use this to connect any equipment that requires a chassis ground Storage and Service Storage Before storing your UPS turn it completely OFF with the UPS ON and receiving utility power press and hold the ON OFF STANDBY button for one second an alarm will beep once briefly after the interval has passed then unplug the UPS from the wall outlet If you store your UPS for an extend ed period of time recharge the UPS batteries once every three months plug the UPS into a wall out let allow it to charge for 12 hours and then unplug it and place it back in storage Note after you plug the UPS in it will automatically begin charging its batteries however it will not supply power to its outlets see Quick Installation section If you leave your UPS batteries discharged for an extended period of time they will suffer a permanent loss of capacity Service Before returning your UPS for service follow these steps 1 Review the installation and operation instructions in this manual to ensure that the service problem does not originate from a misreading of the instructions Also
8. e power during nor mal operation and battery power during blackouts and brownouts The UPS pro tects equipment connected to these receptacles against damaging surges and line noise If you have a serial or USB connection to your UPS you can remotely reboot connected equipment by turning the receptacles OFF and ON using Tripp Lite s PowerAlert Software The receptacles are divided into one or more load banks labelled LOAD 1 etc which may be remotely switched OFF and ON using Tripp Lite UPS software without interrupting power to equipment con nected to the other outlets Outlets labelled UNSWITCHED may not be remotely switched off See software instructions for details Communications Ports USB or RS 232 These ports connect your UPS to any workstation or server Use with Tripp Lite s PowerAlert Software and included cables to enable your computer to automatically save open files and shut down equipment during a blackout Also use PowerAlert Software to monitor a wide variety of AC line power and UPS operating conditions Consult your PowerAlert Software manual or contact Tripp Lite Customer Support for more information See USB and RS 232 Serial Communications in the Optional Installation section for installation instructions EPO Emergency Power Off Port Your UPS features a EPO port that may be used to connect the UPS to a contact closure switch to enable emergency inverter shutdown See Optional Installation Accessory Slot Re
9. e product You ll be automatically entered into a drawing for a chance to win a FREE Tripp Lite product No purchase necessary Void where prohibited Some restrictions apply See website for details Battery Replacement Under normal conditions the original batteries in your UPS will last many years See Safety sec tion before replacing batteries The batteries are designed for hot swap replacement i e leaving the UPS in ON mode but some qualified service personnel may wish to put the UPS in the OFF mode and disconnect equipment before proceeding Procedure El Remove Front Panel B Disconnect Batteries EH Remove Dispose of Batteries B Add Batteries B Connect Batteries Attach connectors black to black and red to red n Replace Front Panel FCC RADIO TV INTERFERENCE NOTICE FOR CLASS A MODELS Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause interference to radio communications Operation of this equipment is likely to cause harmful interference in which case the user will be required to
10. helves can be adjusted in the next step E Adjust each shelf to fit your rack then mount them in the lowest available space of your rack with the screws nuts and washers provided DB Note that the support ledges should face inward Tighten the screws that connect the shelf segments Bl El Attach mounting ears Bl to the front mounting holes of your equipment B using the screws provided The ears should face forward Using an assistant if necessary lift your equipment and slide it onto the mounting shelves Attach your equipment to the rack by using the appropriate hardware B through its mounting ears and into the rack rails 2 Post Telecom Mounting If you desire to mount your UPS in a 2 post rack a Tripp Lite 2 Post Rackmount Installation Kit Model 2POSTRMKITWM sold separately will be required Refer to the 2POSTRMKITWM Owner s Manual for complete installation procedures Mounting Tower Mount your UPS models in an upright tower position using included hardware The user must determine the fitness of hardware and procedures before mounting Stand your UPS on its side with the LED Control panel at the top Attach one rack mounting ear to each side of the UPS using included screws Ej Attach the rack mounting ears to the floor with user supplied hardware A Rotate the LED Control panel to view it easier while the UPS is tower mounted Insert a small screwdriver or other tool in the slo
11. line without the assistance of battery power The UPS will also emit a slight clicking noise These are normal automatic operations of the UPS no action is required on your part OUTPUT LOAD LEVEL LED this multicolored LED indicates the approximate electrical load of equipment connected to the UPS s AC outlets It will turn from green light load to yellow medium load to red overload If the LED is red either illuminated continuously or flashing clear the overload immediately by unplugging some of your equipment from the outlets until the LED changes from red to yellow or green CAUTION Any overload that is not corrected by the user immediately may cause the UPS to shut down and cease supplying output power in the event of a blackout or brownout BATTERY CHARGE LED when the UPS is operating from utility power this LED indicates the approximate charge state of the UPS s internal batteries red indicates the batteries are beginning to charge yellow indicates the batteries are roughly midway through charging and green indicates the batteries are fully charged When the UPS is operating from battery power during a blackout or severe brownout this LED indicates the approximate amount of energy ulti mately affecting runtime which the UPS s batteries will provide red indicates a low level of energy yellow indicates a medium level of energy and green indicates a high level of energy Since the runtime performance of all UP
12. move the small cover panel from this slot to install optional accessories to remotely monitor and control your UPS Refer to your accessory s manual for installation instructions Contact Tripp Lite Customer Support at 773 869 1234 for more information including a list of available SNMP network management and connectivity products Voltage DIP Switches These switches enable you to set the UPS to match actual input voltage If the Voltage DIP Switches are set above or below input voltage the UPS will treat the input as a continuous overvoltage or undervoltage condition and will automatically adjust input voltage to match the Voltage DIP Switch setting This will cause constant unnecessary wear on the UPS system Note The Voltage DIP Switches must be set with the UPS turned OFF and disconnected from utility power If the switches are set while the UPS is connected to utility power the setting will not take effect Basic Operation continued Or NORM DELAY Charge Rate Setting when External Batteries are connected Charge Rate Setting when External Batteries are not connected as O Power Sensitivity Adjustment This dial is normally set fully counter clockwise which enables the UPS to provide maximum protection against waveform distortions in its AC input When such distortion occurs the UPS will normally switch to provi
13. n Optional Installation These connections are optional Your UPS will function properly without these connections USB and RS 232 Serial Ell Communications Use the included USB cable see Kl and DB9 serial cable see Kl to connect the communication port on your computer to the communication port of your UPS Install on your computer the Tripp Lite PowerAlert Software appropriate to your computer s operating system El EPO Port Connection This optional feature is only for those applications which require connection to a facility s Emergency Power Off EPO circuit When the UPS is connected to this circuit it enables emergency shutdown of the UPS s inverter Using the cable provided connect the EPO port of your UPS see E to a user supplied normally closed or normally open switch according to the circuit diagram see EJ The EPO port is not a phone line surge sup pressor do not connect a phone line to this port EJ External Battery Connection Your UPS comes with a robust internal battery sys tem external batteries are needed only to extend run time Adding external batteries will increase recharge time as well as runtime The illustration see ED shows the location of your OPTION 1 USER SUPPLIED NORMALLY CLOSED SWITCH UPS s External Battery Connector where you will q eae insert the battery pack cable Complete installation bo aR instructio
14. n AC supply Connect your UPS to a properly grounded AC power outlet Do not modify the UPS s plug in a way that would eliminate the UPS s connection to ground Do not use adapters that eliminate the UPS s connection to ground Do not plug your UPS into itself this will damage the UPS and void your warranty f you are connecting your UPS to a motor powered AC generator the generator must provide filtered frequency regulated computer grade output Connecting your UPS to a generator will void its Ultimate Lifetime Insurance Equipment Connection Warnings Do not use Tripp Lite UPS Systems for life support applications in which a malfunction or failure of a Tripp Lite UPS System could cause failure or significantly alter the performance of a life support device Do not connect surge suppressors or extension cords to the output of your UPS This might overload the UPS and will void the surge suppressor and UPS warranties Battery Warnings Batteries can present a risk of electrical shock and burn from high short circuit current Observe proper precautions Do not dispose of the batteries in a fire Do not open the UPS or batteries Do not short or bridge the battery terminals with any object Unplug and turn off the UPS before performing battery replacement Use tools with insulated handles There are no user serviceable parts inside the UPS Battery replacement should be performed only by authorized service personnel using the same n
15. ns for your battery pack appear in the battery ar pack owner s manual Make sure that cables are fully USER SUPPLIED NORMALLY OPEN SWITCH inserted into their connectors Small sparks may result ee during battery connection this is normal TE 2 NO CONNECTION Do not connect or disconnect battery packs when the UPS is running on battery power If you connect any external batteries set the Battery Charge Level Switches see EM to the down position This will increase your UPS s charger output so that the additional batteries charge faster Caution DO NOT set the Battery Charge Level Switches to the down position without an external battery connected There is a risk of damaging the UPS s internal battery system Basic Operation Buttons Front Panel ON OFF STANDBY Button To turn the UPS ON with the UPS plugged into a live AC wall outlet press and hold the ON OFF STANDBY button for one second Release the but ton If utility power is absent you can cold start the UPS i e turn it ON and supply power for a limited time from its batteries by pressing and holding the ON OFF STANDBY button for one second To turn the UPS OFF with the UPS ON and receiving utility power press and hold the ON OFF STANDBY button for one second Then unplug the UPS from the
16. o longer sounding CAUTION Any overload that is not corrected by the user immediately following a self test may cause the UPS to shut down and cease supplying output power in the event of a blackout or brownout If the BATTERY WARNING LED remains lit and the alarm continues to sound after the test the UPS batteries need to be recharged or replaced Allow the UPS to recharge continuously for 12 hours and repeat the self test If the LED remains lit contact Tripp Lite for service If your UPS requires battery replacement visit www tripplite com to locate the specific Tripp Lite replacement battery for your UPS Basic Operation continued Indicator Lights Front Panel All Indicator Light descriptions apply when the UPS is plugged into a wall outlet and turned ON POWER LED this green LED lights continuously when the UPS is ON and supplying connected equipment with AC power from a utility source The LED flashes and an alarm sounds 4 short beeps followed by a pause to indicate the UPS is operating from its internal batteries during a blackout or severe brownout If the blackout or severe brownout is prolonged you should save files and shut down your equipment since internal battery power will eventual ly be depleted See BATTERY CHARGE LED description below VOLTAGE CORRECTION LED this green LED lights continuously whenever the UPS is automatically correcting high or low AC voltage on the utility
17. ts on either side of the panel Pop the panel out rotate it and pop the panel back in place Quick Installation H With the UPS disconnected from Toov lit utility power use a small tool to 120v 1 1 1 1 e set the Voltage DIP Switches to match your input voltage UPS is EEE preset to the 120V setting RM DELAY E MANUAL El Plug the UPS into an outlet on a EPO dedicated circuit NOTE after you plug the UPS into a live AC outlet the UPS in Standby mode will automatically charge its batteries but will not supply power to its outlets until it is turned ON see Step 3 below ncludes an additional plug which can be switched by a qualified electrician The BATTERY CHARGE LED will be the only LED illuminated Plug your equipment into the UPS Your UPS is designed to support only electronic equipment You will overload the UPS if the total VA ratings for all the equipment you con nect exceeds the UPS s Output Capacity To find your equipment s VA ratings look on their nameplates If the equipment is listed in amps multiply the number of amps by 120 to determine VA Example 1 amp x 120 120 VA If you are unsure if you have overloaded the UPS s out lets see OUTPUT LOAD LEVEL LED description Turn the UPS ON Press and hold the ON OFF STANDBY button for one second The alarm will beep once briefly after one second has passed Release the butto
18. umber and type of batteries sealed Lead Acid The batteries are recyclable Refer to your local codes for disposal requirements or in the USA only call 1 800 SAV LEAD or 1 800 8 BATTERY 1 800 822 8837 or visit www rbrc com for recycling information Tripp Lite offers a complete line of UPS System Replacement Battery Cartridges R B C Visit Tripp Lite on the Web at www tripplite com to locate the specific replacement battery for your UPS During hot swap battery replacement the UPS will not provide backup power in the event of a blackout or other power interruptions Do not operate UPS without batteries When adding external battery packs to select models with external battery pack connectors connect only Tripp Lite recommended battery packs of the correct voltage and type Do not connect or disconnect battery packs when the UPS is operating on battery power Mounting Rack Mount your equipment in either a 4 post or 2 post rack or rack enclosure The user must determine the fitness of hardware and procedures before mounting If hardware and procedures are not suit able for your application contact the manufacturer of your rack or rack enclosure The procedures described in this manual are for common rack and rack enclosure types and may not be appropriate for all applications 4 Post Mounting Connect the two segments of each shelf using the included screws and nuts El Leave the screws slightly loose so that the s
Download Pdf Manuals
Related Search
Related Contents
S I S T E M A E N L Í N E A - el sistema en linea esta en conseils pratiques Samsung MS28 Solo MWO with Healthy Steam, 28 L User Manual La prothèse de disque Le médicament générique Serre-livres sur la butée arrière Mokon Series Driver User's Manual Solac SP7160 hair dryer ICC ICCMSHB1RS rack accessory Copyright © All rights reserved.