Sun Fire V440 Just the Facts

image

Contents

1. PHY BCM 5421 Ext SCSI NET1 NETO System Architecture Figure 7 Sun Fire V440 Server Block Diagram Sun Fire V440 Server October 7 2003 Just the Facts 23 Sun Proprietary and Confidential Figure 8 Internal Disk Figure 9 Power supply Access Sun Fire V440 Server October 7 2003 Just the Facts 24 Sun Proprietary and Confidential System Rackmounting The Sun Fire V440 Server is intended to operate in a four post rack within a data center The system is only 24 deep and will fit in Sun StorEdge cabinet and most third party 30 32 or 36 depth four post cabinets Data centers typically arrange equipment within racks for the most efficient use of floor space Each Sun Fire V440 ships with a Four post rack kit and cable management arm An optional two post rack mount kit X7417A is also available The server is 4 rack units RU high and within a 36RU Sun StorEdge rack up to 9 fully populated Sun Fire V440 Servers can physically be installed however power and cooling requirements must also be considered Each unit weighs from 70 lbs 32kg minimal configuration to 82 lbs 37kg fully configured For servicing in a four post cabinet slide the system forward from the rack The top panel opens for access to the processor memory modules or the I O subsystem including the PCI adapt
2. To determine the upgrade allowance value apply the allowance code percentage to the list price of a 4 way Sun Fire V440 server This allowance is in addition to any contracted discounts that the customer may be eligible for Customers will need to return a full functioning system within 90 days of receipt of the hardware RMA kits UG RMA must be ordered with each allowance code UG RMA kits provides customers instructions on where to return the used residual equipment Customers will be billed for all non returned equipment Upgrade Paths Sun Upgrade Advantage Program UAP Upgrade From Upgrade To Allowance Code Part Number Return Sun Servers Ultra 5s 10s Enterprise 2 Sun Fire V440 4 way See Worldwide A full functioning Enterprise 250 Enterprise systems only Configuration Guide system 220R Enterprise 450 or Sun Win 94711 Enterprise 420R or and Sun Win 96194 Sun Fire 280R for standard trade in allowances CPU Memory Modules Available 1 062 GHz UltraSPARC Ili 1 28 GHz UltraSPARC Ii See Worldwide A full functioning up to 4 total processor memory module processor memory module Configuration Guide 1 062 GHz processor with 1 MB processor with 1 MB or Sun Win 108142 UltraSPARC IIi internal L2 cache 2GB internal L2 cache 4GB for standard trade in processor memory X 7403A 4x 512MB X 7404A 4x 1GB of allowances module of memory included memory
3. 1 2 GB sec Internal Storage 292 GB 146 GB 436 GB with 36 4 GB drives Removable Media DVD ROM only DVD ROM only 3 slots for up to three 5 25 rem media devices PCI or cPCI slots 6 6 9 no cPCl no cPCl no cPCl 066 MHz 3 2 2 033 MHz 3 4 7 Integrated Network Two 10 100 1000 Ethernet Two 10 100 1000 Ethernet 10 100 and 1 Gbit Ethernet Input Power 110 240 VAC 2 Power cords 1 1 2 Power cords 1 1 3 Power cords N 1 RAS Features Hot pluggable disks hot pluggable power supplies ALOM SCC front and rear power and fault LED indicators Hot pluggable disks hot swap power supplies RSC multipathing to storage and networks LED indicators for power fans and disks Hot pluggable disks PCI slots fans hot swap power supplies RSC multipathing to storage and networks LED indicators for power fans and disks Warranty 3 year on site 2 day service 3 year on site 2 day service 3 year on site 2 day service Minimum O S Solaris 8 HW 07 03 Solaris 8 2 02 Solaris 8 7 01 Sun Fire V440 Server Just the Facts October 7 2003 Sun Proprietary and Confidential Sun Fire V440 Server Features and Benefits Features e Up to four 1 062 1 28 GHz UltraSPARC Hii processors each with 1 MB of internal ECC protected L2 cache and up to 4 GB of ECC error correcting code memory e Space efficient rack optimized 4RU and 24 inch depth enclos
4. GUI in addition to the traditional command line interface The GUI provides error free setup of disks such as mirrors and UFS logs as well as easy on going administration of disk subsystems It delivers a visual representation of the storage subsystem along with drag and drop capabilities both of which are invaluable in managing large complex disk subsystems Other Solstice DiskSuite software features e Disk striping enables parallel I O and load balancing for improved performance e Multipathing support enables Solstice DiskSuite software to use multiple data paths in the case of failure e A performance monitor helps eliminate bottlenecks e Concatenation and the grow file system command allow the construction of large logical devices and enable online expansion and reconfiguration Sun Cluster Software Sun Cluster software provides higher levels of availability than is possible with a single server This solution automates recovery from any single hardware or software failure by automatically restarting a failed application or migrating the application and its resources to a backup server in the event of a hardware failure Sun Cluster software provides mainframe class reliability availability and scalability for e commerce ERP data warehousing and other mission critical applications and services It delivers an easy to use continuously available multiplatform clustering solution that is completely integrated with the Solaris Opera
5. Power Requires 27 Temperature it A ai a ta lie 28 Vibra tias toda to aia 28 AltitUde taas cnc 28 NA E NS 28 BTU Heatiload Data A A 28 Humidity moncondensing cti Nit adi 29 Regulatory isidro wet fuse td dio atea 29 Requirements and Configurations ssip aieea ai ei iape ER EE EE REE o E Ea EE E a 30 Sun Fire V440 Server October 7 2003 Just the Facts 3 Sun Proprietary and Confidential System Requirements ii a wet ice aged da 30 PiGeMSIN S W SAS Criss desir cere AEEA o dl o dida 30 Operating System EnvironMent eee cesecesecsseceseceseeeseeesseeeseeesaecsaecsaecaecsecsseceseesseesseeseaeeeseeeaaeenaes 30 Upgrades to Solaris 8 from Previous Versions cesceeseesseesseessecesecsseceseceseceseeeseeeseeecaeeeaeecaeeesaecnaees 30 System Management ssesitecies tess taps siesealsededeees eeeledoteescdvteseee odes e shse eed weds ese feels Seay tae we ie ieee 31 SystemA dM SAO tetitas 31 OpenBo0t Dia 8nostiC Sonane a a dea e A i a da 32 OpenBoot A O 32 Power On Self Test POS Dia A eee nee a el ela aie 32 Product DOCumMeNtationi s 3 202 sec secelseessaeed exes err n a 33 Solaris Bandwidth Manager Software cceescssssesseseceecsecsseseeseeseceeeseessesecaeeseceeaeesesaeceeeseeaenaeeaeeaeeees 33 Solaris Management Console Software ecesccsssessesesceeeseesseecsecssesecesseeseeseceeaeeseeeeeceaeseseesaeeaeeaeeees 33 Solaris Resource Manager Software cece csesecseeseceeesscssesecseeseceessecnseseesaeseceessecaae
6. developers to create applications based on the CIM schema and XML HTTP communication standards that manage Solaris software systems and administer the Solaris Operating Environment By combining information from diverse applications objects from different vendors can be managed as if they were from one vendor which can greatly reduce the complexity and cost of managing such a heterogeneous system Sun Fire V440 Server October 7 2003 Just the Facts 35 Sun Proprietary and Confidential Solaris Web Start Software Solaris Web Start software a key component of the Solaris Operating Environment is an easy to use Java technology based application that guides system administrators through the installation of both the Solaris Operating Environment and co packaged application software Solaris Web Start software makes installing the Solaris Operating Environment as simple as clicking a button Solaris Web Start software offers the industry s first Web based installation process enabling all of the setup and administration to be done locally or remotely through a web browser It also virtually eliminates the UNIX system administration normally associated with software installation and setup As a result Solaris Operating Environment and co packaged software can be installed by less experienced administrators or administrators familiar with Microsoft Windows installations safely and easily Solaris Web Start Wizards Software Solaris Web Start
7. 36 Sun Proprietary and Confidential e Mirroring Solstice DiskSuite software provides a comprehensive data redundancy solution It transparently maintains a mirror copy of data on another disk and automatically uses the surviving copy in the event of hardware failure e RAID5 The RAID 5 feature in Solstice DiskSuite software provides highly available data storage at a lower cost by using less disk space than mirroring Rather than having a single disk dedicated for parity the parity information is distributed across all disks thereby promoting relatively uniform usage of all disks associated with the logical unit Hot spare On line system recovery is supplemented by the use of a hot spare utility that automatically replaces failed mirror or RAID 5 components This facility migrates new partitions to replace failing ones Users continue to access the surviving copy of the data while a new mirror is automatically generated with no interruptions of operation e UNIX File System UFS logging When coming back online after a reboot UNIX software typically checks file systems for integrity Although a time consuming process especially on large systems it was necessary to avoid data corruption With the UFS logging feature in Solstice DiskSuite software the need for this process has been eliminated Reboots are much shorter and system recovery is faster Solstice DiskSuite software offers a powerful yet simple graphical user interface
8. Facts 44 Sun Proprietary and Confidential A42 XCB4 16GD Sun Fire V440 server with 4 CPUs at 1 28 Ghz 16 GB memory implemented as 16 x 1GB 4 36 GB 1 0 10 000 RPM Ultra320 SCSI disks Also includes A four post rackmount kit with cable management arm DVD IDE drive e ALOM system management module serial network SCC System Configuration Card e Two 680W power supplies providing 1 1 redundancy e Two integrated 10 100 1000 Mb s Ethernet ports 1 DB 9 serial port 4USB ports i e for optional keyboard and mouse Solaris server license Solaris 8 HW 07 03 or later e 3 year second day on site hardware warranty For details regarding the specific warranty for each Sun product please refer to the Sun Warranty Web Page at http www sun com service support warranty Assemble to Order ATO Assemble to order configurations are not available The three preconfigured systems greatly reduce the requirement for custom configurations which generally command a premium in pricing Sun Fire V440 Server October 7 2003 Just the Facts 45 Sun Proprietary and Confidential Memory Configurations Expandability to Processors and Memory All systems fully utilize the available memory DIMM slots Therefore when one selects the e A42 XAB2 04GD 2 processor 4 GB 4 disks system the maximum system configuration that can be achieved without a CPU Memory module exchange is a 4 processor 8 G
9. Java technology Solaris Management Console software can launch any UNIX application on any Solaris server in a network It provides views of servers on the network as well as applications on those servers which allows for easy local and remote administration of multiple servers running Solaris Management Console software It also delivers powerful capabilities to make the process of adding users hosts or applications as simple as pointing and clicking from virtually any client on the network Solaris Management Console software enables administrators to register other Solaris Management Console servers and applications on the network When the console is accessed it dynamically configures tree views of registered hosts and services making it easier to manage each Solaris server Solaris Management Console software enables administrators to view activity on all their servers and modify applications and services running on them Sun Fire V440 Server October 7 2003 Just the Facts 33 Sun Proprietary and Confidential Solaris Management Console software allows administrators to launch applications such as administration tools on a remote server while monitoring the application via a light front end GUI on the client This eliminates the need to download large applications over the network and install and run them on the client With Solaris Management Console software remote servers can be managed easily with tools already located on the s
10. Keyswitch Settings Sun Fire V440 Server October 7 2003 Just the Facts 18 Sun Proprietary and Confidential Position Icon Description Standby This setting forces the system to power off immediately and to enter standby mode It also disables the system Power button This setting is useful when AC DC power is interrupted and you do not want the system to restart automatically when power is restored With the system control keyswitch in any other position 1f the system were running prior to losing power and the power state memory is enabled in the ALOM system controller the system restarts automatically once power is restored The Standby setting also prevents anyone from restarting the system during an ALOM system controller session However the ALOM system controller card continues to operate using the system s standby power Normal This setting enables the system Power button allowing you to power the system on or off If the operating system is running pressing and releasing the Power button initiates a graceful software system shutdown Pressing and holding the Power button in for four seconds causes an immediate hardware power off Locked This setting disables the system Power button to prevent unauthorized users from powering the system on or off It also disables the keyboard L1 A Stop A command terminal Break key command and tip window command preventing users from suspending system operation
11. V240 and Sun FireTM V210 e Scale systems to suit specific application needs with up to four UltraSPARC Ili CPUs six PCI slots up to nearly 300GB of internal storage and a maximum of up to 16GB of memory e Lower TCO due to aggressive price points dense from factor and low power and cooling requirements that help to alleviate growing pressures on shrinking IT budgets Improve network performance and efficiency with the two built in 1 Gb Ethernet ports of the Sun Fire TM V440 server e Reduce complexity via the Advanced Lights Out Manager ALOM integrated system management and Sun Management Center SunMC hardware and software e Achieve higher availability for mission critical applications with redundant hot pluggable components and serviceability with a pre installed System Configuration Card SCC that can easily transfer system identity from one system to another Sun Fire V440 Server October 7 2003 Just the Facts 10 Sun Proprietary and Confidential Enabling Technology Technology Overview The Sun Fire V440 is the next generation server available for high density compute intensive environments Design characteristics are focused on a low entry price point with high performance serviceability and reliability The Sun Fire V440 server is powered by one to four UltraSPARC Ili CPUs and can be configured with up to 16 GB of memory to support any application to offer the widest flexibility in service delivery
12. all front panel status LEDs are powered by the system s 5 volt standby power source fault LEDs remain lit for any fault condition that results in a system shutdown Locator Fault and System Activity LEDs are also found at the upper left corner of the back panel Also located on the back panel are LEDs for the system s two power supplies and RJ 45 Ethernet ports See Sun Fire TM V440 Front Panel Features in Figure 2 on page 16 Sun Fire TM V440 Server Back Panel Features in Figure 4 on page 20 for locations of the front panel and back panel LEDs During system startup LEDs are toggled on and off to verify that each one is working correctly The following tables list and describe the LEDs on the front panel system LEDs power supply LEDs and hard disk drive LEDs Listed from left to right the system LEDs operate as described in the following table System LEDs Sun Fire V440 Server October 7 2003 Just the Facts 16 Sun Proprietary and Confidential Name Description Locator This white LED is lit by Sun Management Center or Sun Advanced Lights Out Manager software or by Solaris command to locate a system Service Required This amber LED lights to indicate that the system hardware or software has detected a system fault This LED lights for any faults or failures detected in any of the following CPU memory module Memory DIMM Fan tray Power supply System Activity This green LED lights w
13. controller which utilizes the Qlogic 2100 series chip is also not supported on UltraSPARC Ili systems X6799A PCI to Single FC AL Adapter This adapter was originally introduced to provide connectivity to external FC AL storage arrays for the Sun Fire 280R This product is available for use on all currently available UltraSPARC II III and IIi based systems The product provides a single FC AL loop and no internal connector For applications with multiple external FC AL storage arrays and or loops the X6727A is preferable as it will conserve PCI slots Sun Fire V440 Server October 7 2003 Just the Facts 46 Sun Proprietary and Confidential Storage Configurations and Support Network Storage is responsible for defining and supporting the configurations of host bus adapters and external storage arrays in combination with drivers and storage management tools regardless whether the arrays utilize SCSI or FC technology These same components will influence the functionality available for the internal storage array as well FC AL loops Supported configurations require that individual FC AL loops are connected only to a single type of array However individual loops of a multi loop controller i e X6727A PCI to dual FC AL controller may be connected to different types of arrays provided that all arrays on any individual loop are the same Multipathing and Benefits Multipathing provides two independent hardware connections to a disk or an
14. of a system contributing to continuous operation and minimizing system downtime for services Together reliability availability and serviceability provide for near continuous system operation Duplication for the purpose of achieving fault tolerance Refers to duplication or addition of components Small Computer Systems Interface An ANSI standard for controlling peripheral devices by one or more host computers A subset of the Pre configured Systems PTOs which offer accelerated delivery time See Mirroring October 7 2003 62 Sun Proprietary and Confidential Materials Abstract All materials are available on SunWIN except where noted otherwise Token or Collateral Description Purpose Distribution COMAC Order Product Literature Sun Fire V440 Server Just The Reference Guide this Training SunWIN Facts document Sales Tool Reseller Web Sun Fire V440 Server Customer Customer Presentation Sales Tool SunWIN Token Presentation Reseller Web 368875 Sun Fire V440 Server Data Sheet Data Sheet Sales Tool SunWIN Reseller Web Sun Fire V440 Configuration Configuration Guide Sales Tool SunWIN Guide Reseller Web References External Web Sites General Information on the Sun http www sun com servers entry V440 index html Fire V440 Server Features and Benefits of the Sun http www sun com servers entry V440 features html Fire V440 Server Specifications of the Sun F
15. telephone coverage 7 day 24 hour Yes Option Option N A on site coverage 7 day 12 hour No Option No No on site coverage 5 day 24 hour No Option No No on site coverage Coverage Response Time cont Customer defined Yes Yes Yes Option priority setting Sun Fire V440 Server Just the Facts October 7 2003 Sun Proprietary and Confidential 58 SUNSPECTRUM SUNSPECTRUM SUNSPECTRUM SUNSPECTRUM FEATURE PLATINUM GOLD SILVER BRONZE Mission critical Business critical Systems Support Self Support Support Support Note Urgent phone on site Live transfer Live transfer Live transfer 4 hour N A 2 hour 4 hour 4 hour Note Serious phone on Live transfer 2 hour next day 2 hour next day 4 hour N A site 4 hour Note Not critical phone on Live transfer 4 hour 4 hour 4 hour N A site customer customer customer convenience convenience convenience 2 hour on site response Yes Option Option N A Additional contacts Option Option Option Option Premier Support Features Mission critical support Yes For urgent No No team problems Sun Vendor Integration Yes Yes No No Program SunVIP Software patch management Yes No No No assistance Field change order FCO Yes No No No management assistance Hardware Support Delivery Replacement hardware parts On site technician On site technician On site technician C
16. the following e Backups Enable on line processing to continue while backup processes backup a point in time snapshot image of on line data e Data warehouse loading Populate a data warehouse from a snapshot image of on line data e Application development and testing Make a snapshot image of production data available as test data for new applications e Data migration Use Sun StorEdge Instant Image software to help migrate from one storage platform to another VERITAS Volume Manager VxVM Software VERITAS Volume Manager VxVM software provides easy to use on line disk storage management for enterprise computing environments Traditional disk storage management is a labor intensive process often requiring machines to be taken off line a major inconvenience to users Once the system is off line the system administrator is faced with the tedious process of backing up existing data manually changing system parameters and reloading the data In today s distributed client server environments users are demanding that databases and other resources be available 24 hours a day are easy to access and are safe from corruption or loss caused by hardware malfunction VxVM software provides system administrators with the tools to dynamically configure disk storage to perform administrative tasks while the system is active and to analyze disk usage VxVM software provides on line administration of disk resources so that the disk subsystems c
17. to access the system ok prompt The Locked setting is recommended for normal day to day operations and prevents unauthorized programming by write protecting system firmware The ALOM system controller can still affect the system power state via a password secured ALOM session even when the system control keyswitch is in the Locked position This capability provides remote management of the system Diagnostics amp This setting forces the power on self test POST and OpenBoot Diagnostics software to run firmware diagnostic tests at power on or during reset events The Power button functions the same as when the system control keyswitch is in the Normal position Back Panel Features Sun Fire V440 Server Just the Facts Figure 4 Back Panel Features October 7 2003 19 Sun Proprietary and Confidential eiii hi la Serial MEET si Hat Management E i techerner LOM CNL 10 5 amp Sun Chalupa Server Rear View Uni Conard Design mico Fiesta Server Family Sun Proprietary Confidential Hard to Know AENA The back panel includes these features System status LEDs Inlets for both AC power supplies Six PCI card slots Serial management port labeled SERIAL MGT located on the back of the ALOM system controller card Network management port labeled NET MGT located on the back of the ALOM system controller card Eight external data ports including the following One DB 9 s
18. 12MB or 1GB A group of four DIMMs Error correcting code IEEE standard for 100 Mb second Ethernet This technology supports a data transfer rate of 100 megabits per second over special grades of twisted pair wiring Capability of a system to mask many individual errors but not all This approach generally requires redundancy of some components and additional software An example would be the dual path capability and automatic failover for storage and networks Another term for high availability Capability of a system to mask any individual point of failure This type of system is typically implemented with redundancy of components and synchronization of clock signals to maintain each unit in lock step with it s counterpart Fibre Channel arbitrated loop A loop topology used with Fibre A bus used for environmental monitoring Capability of a system to mask many individual points of failure or to significantly compensate for them This type of system is built upon standard components with limited hardware and or software components to minimize the impact of failures Generally this type of system is less costly than a fault tolerant system Please see Adapter A component that can be electrically safe to remove or add while the system is still running Typically the system must be rebooted before the hot plug component is configured Maintaining a redundant logical copy of a disk volume for higher availability Also know
19. 22 Class A per EMC Directive 89 336 EEC CE Mark VCCI Class A Industry Canada ICES 003 AS NZ 3548 Australia New Zealand CNS 13438 Taiwan KSC 5858 MIC Mark Korea Immunity IEC 1000 EN55024 per EMC Directive 89 336 EEC including IEC 61000 4 2 Electrostatic discharge immunity test IEC 61000 4 3 Radiated radio frequency electromagnetic field immunity test IEC 61000 4 4 Electrical fast transient burst immunity test IEC 61000 4 5 Surge immunity test IEC 61000 4 6 Immunity to conducted disturbances induced by radio frequency fields IEC 61000 4 8 Power frequency magnetic field immunity test IEC 61000 4 11 Voltage dips short interruptions and voltage variations immunity tests Line Distortion EN 61000 3 2 per EMC Directive 89 336 EEC Voltage Fluctuations and Flicker EN 61000 3 3 per EMC Directive 89 336 EEC Sun Fire V440 Server October 7 2003 Just the Facts 29 Sun Proprietary and Confidential Requirements and Configuration System Requirements The Sun Fire V440 Server requires Solaris 8 HW 07 03 plus recommended patches or later Note Solaris 9 support will be available in the Solaris 9 HW 12 03 release Licensing Usage Operating System Environment The Sun Fire V440 Server qualifies under the Free Solaris Binary License Program For only a nominal cost of media and shipping the Solaris 8 operating environment may be used without paying a license fee on an unlimited number of com
20. B system This configuration may be obtained by adding two of the X 7415A options as shown below Configuration Description Maximum Number of Additional Modules Possible A42 XAB2 04GD 2x SE 4 GB 4 2 X7415A 1x1 062GHz 2GB e For tradeins and exchanges of faster processor speeds or increased memory capacity contact IBB for available memory upgrade exchange programs Also please see Sun Upgrade Allowance Program on Page 56 for more information regarding exchanges of CPU Memory modules It is encouraged that one carefully consider the growth potential application and budget constraints when selecting the system Classic applications such as database and CAE can generally take advantage of large memory and the fully configured system may be appropriate The maximum memory capacity for the Sun Fire V440 server is 16GB Storage Configuration Guidelines Host Bus Adapters X6729A PCI to FC AL Adapter The X6729A is not supported with UltraSPARC Hli systems This adapter utilizes the Qlogic 2100 series chip which as since been superseded by the Qlogic 2200 series The IFP driver support for this device does not provide all of the features especially failover capabilities that are available with the leadville driver and the Qlogic 2200 implementation Limited resources and emphasis on higher availability preclude maintaining both devices Note For similar reasons the X2069A combination Gigabit Ethernet and FC AL
21. CI Combination Adapters X1032A PCI to 10 100 Base T plus Single ended 6 Ultra Wide SCSI adapter X2222A Dual Fast Ethernet Dual SCSI PCI Adapter 2 Note The X 2069A Gigabit Ethernet plus FC AL is not supported in UltraSPARC Ili systems PCI Interoperability X2132A SunPCi Co Processor with 733MHz Celeron CPU 3 X1074A Sun PCI Card SunCluster Interconnect 2 X2134A Sun PCI3 2 PCI Encryption X6762A Crypto Accelorator 1000 Deimos 2 X4011A Venus Encryption Card Copper POST RR 1 X4012A Venus Encryption Card Fibre POST RR 1 Sun Fire V440 Server Just the Facts October 7 2003 Sun Proprietary and Confidential 50 PCI Video and Graphics Adapters X3768A EOL d Q3FY03 2 X3769A XVR 100 Papaya 2 X3685A XVR 500 graphics PCI adapter IFB Lite 2 X3780A GA Q2FY04 XVR 600 IFB3 Lite NOTE Post GA support planned Not supported in Solaris 8 HW 07 03 but drivers may be available for download separately 2 X3689A XVR 1200 IFB3 2 Power Cords X311L Power Cord Kit U S Asia 2 X312L Power Cord Kit Continental Europe 2 X386L Power Cord Kit Australia 2 X317L Power Cord Kit U K 2 X314L Power Cord Kit Switzerland 2 X384L Power Cord Kit Italy 2 X383L Power Cord Kit Denmark 2 530 3096 01 Power Cord Jumper extends any geography 2 specific power cord Note One power cord required per power supply Two required per syst
22. ERITAS NetBackup software cost effectively automates backup and recovery for thousands of nodes across multiple servers while enabling the enterprise to manage its storage from a single console With optional add on modules VERITAS NetBackup software provides high performance hot or cold database backup as well as archive capabilities that allow the enterprise to effectively manage data that is rarely accessed yet requires long term storage VERITAS NetBackup software features sophisticated media and device management capable of managing media across the enterprise from a single location and enabling sharing of tape robotics hardware with other applications Sun StorEdge Instant Image Software Sun StorEdge Instant Image software is a point in time copy facility which runs on a Solaris Operating Environment application or storage server Instant Image will enhance the ability of businesses to achieve non stop business Sun Fire V440 Server October 7 2003 Just the Facts 41 Sun Proprietary and Confidential processing by capturing frequent snapshots of live data for independent read and write purposes Sun StorEdge Instant Image software enables point in time copies or shadow volumes to be created on a Sun storage system A shadow volume is a replicated view of data which has been frozen at a specific point in time and is used to enable a secondary application to non disruptively access a primary application s data Product applications include
23. F mean time between failures MTBF measures system reliability for duration until a system will fail This measurement is influenced by quality design environmental considerations such as power and cooling and even operational errors i e how well the hardware and software verifies the intention of staff MTBF Sun Fire V440 Server October 7 2003 Just the Facts 25 Sun Proprietary and Confidential MTTR mean time to restore MTTR is a measure of system maintainability and usually includes diagnostic and repair times only Dispatch and response time of service personnel are typically not included in this calculation as this factor is dependent upon service contracts SLAs geographical conditions etc which can radically influence the measurement Nevertheless these times will ultimately influence availability Simplistically stated Availability MTBF MTBF MTTR These documents will indicate that the system can provide extremely high levels of availability MTTR The vast majority of FRUs can be replaced in under 30 minutes by the average trained service engineer Those components requiring a longer time for replacement generally have a significantly higher MTBF The time for replacement does not include time for diagnosis Sun Fire V440 Server October 7 2003 Just the Facts 26 Sun Proprietary and Confidential Installation Data Hardware Dimensions US Metric Height 4RU Ra
24. Fire V440 Advantages Lower Pricing in all configurations Integrated Dual GB Ethernet Platform SPARC Solaris from smallest configuration to largest IBM has over 10 Operating systems to support Larger number of applications written on Solaris HP rx5670 Sun Fire V440 Advantages Physical system only 24 depth compared to over 30 depth and 7RU Lower Pricing in all configurations Integrated Dual GB Ethernet Platform SPARC Solaris from smallest configuration to largest Large number of applications written on Solaris Against competitive UNIX systems we have significantly lower pricing in all configurations larger memory capacity and a single US IIi Solaris architecture focus We are currently the market share leader in the UNIX server space and the Sun Fire V440 with its memory capacity and two Gigabit Ethernet ports should continue to expand this lead Point Counterpoint This section provides anticipated comments and objections that may be encountered when presenting the Sun Fire V440 server Clock speed of UltraSPARC IMi systems and Sun Fire V440 is relatively slow in comparison to others i e 1 28GHz vs 1 6 GHz of Intel Counterpoint Clock speed is not indicative of performance by itself Cycles can be used very very differently Consider the levels of cache and pipelining from UltraSPARC III as well as the system interconnect in addition to the clock spee
25. G to side Vibration Operating Non operating Sine Vibration Vibration Z axis 0 15G Z axis 0 50 G X Y axes 0 25 G 0 to10 000 feet 5 500 Hz sine 5 500 Hz sine Altitude Altitude Operating Non operating VER 0058 213 0 to 3 000m 0 12 000 m 0 to 40 000 feet Noise In accordance with ISO 7779 Operating acoustic noise 6 7 Bels Idling acoustic noise 6 7 Bels BTU Heat load Data Maximum Heat Dissipation 650W 2218 BTU hr Sun Fire V440 Server Just the Facts October 7 2003 Sun Proprietary and Confidential 28 Humidity noncondensing Operating 20 80 noncondensing 27 C max wet bulb Non operating 5 93 noncondensing 38 C max wet bulb Regulatory Meets or exceeds the following requirements Product Safety UL approval to UL 60950 EN60950 C22 2 No 60950 and CB Report for IEC 950 all including Amendments 1 2 3 4 and 11 and full worldwide deviations TUV approval to EN60950 IEC 950 GOST Certification for Eastern Block countries Korean MIC Certification China CCC mark using UL as agent CE Declaration of Conformance SMI self declaration to The Electromagnetic Compatibility Directive and Low Voltage Directive with accompanying Technical Data File Approval to Argentinian standards using UL as agent EMI 47 CFR 15B Code of Federal Regulations Part 15 Subpart B Class A EN550
26. If you remove the SCC while the system is running the system will power off within 30 seconds In addition if the system is in standby mode and the SCC is missing the ALOM system controller prevents the system from being powered on About Reliability Availability and Serviceability Features Reliability availability and serviceability RAS are aspects of a system s design that affect its ability to operate continuously and to minimize the time necessary to service the system Reliability refers to a system s ability to operate continuously without failures and to maintain data integrity System availability refers to the ability of a system to recover to an operational state after a failure with minimal impact Serviceability relates to the time it takes to restore a system to service following a system failure Together reliability availability and serviceability features provide for near continuous system operation To deliver high levels of reliability availability and serviceability the Sun Fire V440 server offers the following features Sun Fire V440 Server October 7 2003 Just the Facts 21 Sun Proprietary and Confidential Hot pluggable disk drives e Redundant hot pluggable power supplies Sun Advanced Lights Out Manager ALOM system controller Environmental monitoring and fault protection Automatic system recovery ASR capabilities e Multiplexed I O Hardware watchdog mechanism and XIR Hardware RAID
27. Manager 1 2 software helps you control costs and ensure that the enterprise applications your company depends on are allocated their share of available system resources It redefines the traditional single application system model and offers a better solution by enabling you to consolidate multiple applications on a single UNIX server or in a highly available Sun Cluster environment and deliver predictable service levels With Solaris Resource Manager software you control server resources using methods similar to those found on expensive mainframes Multiple users groups and applications can be guaranteed predictable service levels on a single server By dynamically allocating unused CPU capacity to active users and applications resource utilization is increased And since you can set and enforce policies that control how resources are used systems are easier to manage Simply put your enterprise makes the most of the resources it already has Ensures Service Availability The challenge for IT managers today is to provide a consistent level of service to sites with large numbers of users To accomplish this and keep costs under control you need the right tools For example power users such as Wall Street traders may occasionally need faster access to execute a complex query while other users in the same environment have more consistent workloads With Solaris Resource Manager software you can allocate resources so that both groups get the re
28. SI RAID controller The system provides two on board Gigabit Ethernet ports which support modes of operations at 10 100 and 1000 megabits per second Mbps Additional Ethernet interfaces or connections to other network types can be provided by installing the appropriate PCI interface cards Multiple network interfaces can be combined with multipathing software to provide hardware redundancy and failover capability Should one of the interfaces fail the software can automatically switch all network traffic to the alternate network to maintain network availability The Sun Fire TM V440 server provides two serial communication ports one a DB 9 connector on the system back panel and the other an RJ 45 connector labeled SERIAL MGT on the back panel of the Sun Advanced Lights Out Manager ALOM system controller card The back panel also provides four Universal Serial Bus USB 1 0 ports for connecting USB peripheral devices such as modems printers scanners digital cameras or a Sun Type 6 USB keyboard and mouse The USB ports support both isochronous mode and asynchronous mode The ports enable data transmission at speeds of 1 5 Mbps or 12 Mbps The local system console device can be either a standard ASCII character terminal or a local graphics console The default connection is through the serial management port on the back of the Sun Advanced Lights Out Manager ALOM system controller card You can connect an ASCII character terminal to the T
29. Sun Fire V440 Server Just the Facts SunWIN token 386033 PARTNER VERSION October 7 2003 Version 1 61 Copyrights 2000 2001 Sun Microsystems Inc All Rights Reserved Sun Sun Microsystems the Sun logo Sun Fire Ultra UltraComputing Sun Enterprise Sun Enterprise Ultra Starfire Solaris Sun WebServer OpenBoot Solaris Web Start Wizards Solstice Solstice AdminSuite Solaris Management Console Sun Enterprise Authentication Mechanism SunScreen Solstice DiskSuite Sun StorEdge Sun StorEdge LibMON Solstice Site Manager Solstice Domain Manager Solaris Resource Manager ShowMe ShowMe How SunVTS Solstice Enterprise Agents Solstice Enterprise Manager Java ShowMe TV Solstice TMNscript SunLink Solstice SunNet Manager Solstice Cooperative Consoles Solstice TMNscript Toolkit Solstice TMNscript Runtime SunScreen EFS PGX PGX32 SunSpectrum SunSpectrum Platinum SunSpectrum Gold SunSpectrum Silver SunSpectrum Bronze SunStart SunVIP SunSolve and SunSolve EarlyNotifier are trademarks or registered trademarks of Sun Microsystems Inc in the United States and other countries All SPARC trademarks are used under license and are trademarks or registered trademarks of SPARC International Inc in the United States and other countries Products bearing SPARC trademarks are based upon an architecture developed by Sun Microsystems Inc Sun Fire V440 Server October 7 2003 Just the Facts Sun Proprietary and Confide
30. TYB DB 9 connector on the system back panel A local graphics console requires installation of a PCI graphics card monitor USB keyboard and mouse You can also administer the system from a remote workstation connected to the Ethernet or from an ALOM console ALOM is a secure server management tool that lets you monitor and control your server over a serial line or a 10 Mb Ethernet network connection ALOM provides remote system administration for geographically distributed or physically inaccessible systems The firmware installed on the ALOM card allows you to monitor the system without having to install software before using it The ALOM shell command tool scadm supplants much of the functionality of the OpenBoot environmental monitoring utility in previous systems The ALOM card runs independently of the host server and operates off of 5 volt standby power from the system s power supplies This allows ALOM to serve as a lights out management tool that continues to function even when the server operating system goes offline or when the server is powered off The basic system includes two 680 watt power supplies each with two internal fans The power supplies are plugged directly into the motherboard One power supply provides sufficient power for a maximally configured system The second power supply provides 1 1 redundancy allowing the system to continue operating should the first power supply fail A power supply in a redundant configuratio
31. The Sun Fire V440 server is targeted at Tier 1 and Tier 2 applications like Web servers media streaming caching security and application servers The architecture and design of the server provides an extremely powerful and well balanced system to eliminate bottlenecks and maintain service availability Sun Fire V440 servers have the following system architectural features e UltraSPARC Ili processor s with integrated 1MB of on chip internal L2 cache Superscalar SPARC V9 processor technology e J Bus system databus running between 177MHz for 1 062GHz configuration and 183MHz for 1 28GHz configuration Integrated Networking e ALOM e Low power consumption UltraSPARC Illi Processor The UltraSPARC IlIi processor is a highly integrated processor that implements the 64 bit SPARC V9 architecture and Sun s Visual Instruction Set VIS The UltraSPARC IIIi processor contains primary data and instruction caches and a unified 1MB L2 Cache It also contains a DDR1 SDRAM memory controller a JBus controller and sophisticated power management capabilities A high performance integrated processor the UltraSPARC IIi processor is used with a wide range of applications Its RISC architecture and VIS instruction set make it ideally suited for compute servers and embedded applications in tele communications and imaging Support for the Visual Instruction Set VIS is the means to accelerate multimedia networking encryption and Java process
32. Three Sun Fire V440 server Standard Configurations and one bundled configuration with the Sun StorEdge 3310 will be offered Marketing Part Number Configuration Description A42 XAB2 04GD Sun Fire V440 server with 2 CPUs at 1 062 Ghz 4 GB memory implemented as 8 x 512MB 4 36 GB 1 0 10 000 RPM Ultra320 SCSI disks Also includes A four post rackmount kit with cable management arm DVD IDE drive e ALOM system management module serial network SCC System Configuration Card e Two 680W power supplies providing 1 1 redundancy e Two integrated 10 100 1000 Mb s Ethernet ports 1 DB 9 serial port e 4USB ports i e for optional keyboard and mouse Solaris server license Solaris 8 HW 07 03 or later e 3 year second day on site hardware warranty A42 XAB4 08GD Sun Fire V440 server with 4 CPUs at 1 062 Ghz 8 GB memory implemented as 16 x 512MB 4 36 GB 1 0 10 000 RPM Ultra320 SCSI disks Also includes A four post rackmount kit with cable management arm DVD IDE drive e ALOM system management module serial network SCC System Configuration Card e Two 680W power supplies providing 1 1 redundancy e Two integrated 10 100 1000 Mb s Ethernet ports 1 DB 9 serial port 4USB ports i e for optional keyboard and mouse Solaris server license Solaris 8 HW 07 03 or later e 3 year second day on site hardware warranty Sun Fire V440 Server October 7 2003 Just the
33. When future security products from Sun or third parties become available these products can be easily plugged into the interface without requiring modifications to the application enabling customers to adopt evolving security technologies quickly and easily For example if Sun developed a public key security mechanism in the future this mechanism would be easily accessible by any application that uses the RPCSEC GSS interface Sun Management Center Software Sun Management Center software is a scalable SNMP based platform for managing Sun servers The most advanced systems management solution from Sun to date Sun Management Center software offers a single point of management for all Sun servers desktops storage systems the Solaris Operating Environment applications and data center services Sun Management Center software lets customers scale from management of a single system to thousands of systems on a single unified management platform And it integrates easily with leading third party platforms for added flexibility With predictive failure reporting and comprehensive event and alarm management Sun Management Center software warns customers of potential problems so they can solve them before they cause downtime Sun Management Center Sun Fire V440 Server October 7 2003 Just the Facts 39 Sun Proprietary and Confidential software simplifies the management of their Sun environment so customers can use their administration staff
34. Wizards technology extends the point and click simplicity of Solaris Web Start software bringing this same ease of use to applications written for the Solaris Operating Environment Built into new applications Solaris Web Start Wizards software simplifies the installation setup and administration of native Solaris Operating Environment and Java technology based applications Applications built with Solaris Web Start Wizards software can be installed on a Solaris Operating Environment system locally or remotely from virtually any client running a web browser supporting the Java programming language With Solaris Web Start Wizards software the source for an application may be a CD ROM drive on the administrator s PC a drive on the network or a URL on the Web The administrator may be using a Solaris Operating Environment workstation a Microsoft Windows or Macintosh PC or a network computer Solaris Web Start Wizards software is based on technology supplied by and supported by InstallShield Software Corporation a industry leading install tools vendor For administrators the inclusion of Solaris Web Start Wizards software with the Solaris Operating Environment makes installing applications as easy as installing Microsoft Windows applications Solstice CMIP Software Solstice CMIP 8 2 1 software is the foundation of the Solstice Telecommunications Management Network TMN product family It is the Common Management Information Protocol CMIP
35. ack provides customer the capability for low cost horizontally scalable solutions Value Proposition 2 LOW priced 4 way server for Network Computing The Sun Fire V440 Server is priced to beat competitive Lintel Wintel and UNIX 4 way rack optimized servers Value Proposition 3 LOW Total Cost of Ownership Low product procurement costs reduced power and cooling requirements and SPARC Solaris binary compatibility Value Proposition 4 COMPETITIVE price performance UltraSPARC lIIi technology is designed for low cost computing Value Proposition 5 REDUCED Customer Cost and Complexity Advanced Lights Out Manager ALOM provides remote management functionality lowering the requirement for onsight staff The System Configuration Card SCC increase system availability by enabling fast return to service in the unlilkely event of a failure Sun Fire V440 Server October 7 2003 Just the Facts 9 Sun Proprietary and Confidential Key Messages The Sun Fire V440 server helps customers to e Build low cost network solution by supporting Solaris and the Sun ONE software portfolio e SPARC Solaris software binarly compatibility ranging from low end uniprocessor systems to the 106 way E15K server e Reduce real estate cost and increase return on investment with its high density 4P 4RU form factor The Sun Fire TM V440 server is part of the ultra dense UltraSPARCHIi based rack optimized server family of products including the Sun FireTM
36. al L2 cache and the Sun Fireplane Interconnect the Sun Fire V480 server offers exceptional processing power in a compact SRU rack optimized server package The target customers are internet application service providers along with financial services compute farms or any customers running CPU demanding applications Sun Fire V880 Server 8 processor UltraSPARC II The Sun Fire V880 is a rackmountable tower that is the high end workgroup server This versatile high performance and reliable server provides a growth path for today s E450 and E3500 customers who require more application scalability higher performance and built in availability and reliability components Sun Fire V440 Server Just the Facts October 7 2003 Sun Proprietary and Confidential The following chart provides a comparison of the family of Sun Fire Servers Sun Fire V440 Sun Fire V480 Sun Fire V880 Product Positioning Low end 4 way Volume Server Mid size 4 way Volume Server High end 8 way Volume Server Packaging 4 RU rack optimized 25 Depth includes bezel 5 RU rack optimized 24 depth Tower or rack mountable 17 R 32 9 Depth Typical Environment Data Center Data Center Branch Office Department or Data Center CPUs 1 4 2 4 2 8 Memory Max 16 GB 32 GB 64 GB System Bus 2 34 GB sec 9 6 GB sec 9 6 GB sec 1 0 bandwidth 1 84 GB sec 1 2 GB sec
37. all in a recent Data Communications performance test that included the top firewall vendors Given SunScreen SPF software s internal design and optimization SPF should run even faster The performance of SunScreen SPF software enables it to keep up with the demands required to screen large amounts of Internet traffic The stealth design which makes SunScreen SPF software not addressable with an IP address provides two benefits The stealthing makes SunScreen SPF software more secure as potential intruders can not address the machine running SunScreen SPF 200 software Also installation of SunScreen SPF software into the network is easy since the administrator can install it without changing routing tables The stealth design hardens the operating system and turns the system into a dedicated SunScreen SPF software system that only runs SunScreen SPF 200 software Hardening the operating system enhances security since other applications do not run on the system there is less exposure SunScreen SPF software uses a separate administration station that can be any SPARC machine and need not be dedicated State of the art SunScreen SKIP encryption technology provides secure network communication and acts as the infrastructure for electronic commerce Extranets and secure remote access SunScreen SKIP software protects the data being transmitted helps ensure its integrity and provides a high level of authentication SunScreen SPF software covers bot
38. an be managed without interrupting users or applications Disk spanning helps eliminate media size limitations and allows load balancing and extension of file systems and databases Disk mirroring increases data availability in the case of disk failures It also provides a hot relocation algorithm allowing subdisks to be relocated from a failing disk VxVM software provides disk striping and RAID features to increase I O throughput and fault tolerance It provides support for performance monitoring and flexible allocation of free space for application load balancing Veritas Volume Manager software actively supports multiported disk arrays It automatically recognizes multiple I O paths to a particular disk device within the disk array The dynamic multipathing DMP feature provides greater reliability by providing a path failover mechanism In the event of a loss of one connection to a disk the system continues to access the critical data over the alternate connection to the disk The multipathing functionality also provides greater I O throughput by balancing the I O load uniformly across multiple I O paths to the disk device VxVM software provides an easy to use graphical administrative interface providing the ability to quickly create disk configurations reducing administrative costs It also presents a logical pool of free space which can be automatically or directly allocated The on line architecture allows the partitioning of arbitrary areas
39. anage and control all enterprise wide logins from a single console which helps their enterprise reduce the total cost of administering and managing security Strong encryption support Sun Enterprise Authentication Mechanism software provides strong encryption support During the authentication process all the information exchanged between customers and the KDC is encrypted for an extra level of security SEAM software also uses an encrypted channel when storing KDC entries over the network Ease of use Sun Enterprise Authentication Mechanism software supports a Java technology based administrative tool for easy access and configuration It also enables users to load authentication information in batch mode which is particularly useful if the enterprise loses or gains large numbers of users each year Sun Enterprise Authentication Mechanism software supports single sign on capabilities With single sign on SEAM software can authenticate users to gain access to multiple applications by ticketing them only once when they first log in It also spares users the need to memorize multiple passwords or enter passwords multiple times in a session e Higher availability Sun Enterprise Authentication Mechanism software s distributed architecture provides enterprises with higher availability With SEAM software customers can replicate their security information This provides faster access to information as well as duplicate copies in the ev
40. and technical resources more efficiently and help reduce the cost of delivering network services Sun Management Center software enables administrators to spend more time optimizing service delivery less time dealing with management complexity For example Sun Management Center software provides remote online control so administrators can work from virtually anywhere No cease management provides uninterrupted monitoring while new features are added or existing features are reconfigured And built in security enables multiple administrators with different responsibilities to manage the environment Sun Management Center software provides real time system performance and configuration data enabling administrators to isolate bottlenecks It even provides optional centralized data storage and performance analysis including historical trend analysis Sun Management Center software delivers everything administrators need to perform Remote System Configuration on systems with Dynamic Reconfiguration enabled monitor performance and isolate hardware and software faults all through an easy to use Java technology interface It provides e A single point of management enabling administrative resources to be used more effectively e Active configuration management controls providing a secure interface for remote dynamic reconfiguration capabilities and helping to ensure availability A single event model enabling information to be shared wit
41. are distributed as follows PCI bus 1 3 PCI slots 33MHz PCI bus 2 2 PCI slots 66MHz PCI bus 3 1 PCI slot 66MHz and Ethernet PCI bus 4 Ethernet and 4 internal Ultra320 SCSI 320 MB sec disks PCI based controllers provide industry standard economical I O adapters Solaris Operating Environment Utilizing the multiprocessor capabilities of the Sun Fire V440 server a customer can leverage the performance capabilities of Solaris Operating Environment s multithreaded application base As a result of Solaris all previous applications developed and running on Solaris 2 6 and Solaris 7 can be run without recompiling Implementing Sun s UltraSPARC IIIi processor memory and J Bus Interconnect architecture a company will notice the significant improvement in application price performance Solaris supports superior Reliability Availability Serviceability RAS for secure large scale e commerce applications Binary compatibility with previous releases Availability of Product Volume shipments for the Sun Fire V440 Server are scheduled for Q3CY2003 Target Users The Sun Fire V440 server is a cost effective four way server that provides users the ability to horizontally scale their environment with a significant price performance advantage over comparable competitive systems The Sun Fire Sun Fire V440 Server October 7 2003 Just the Facts 6 Sun Proprietary and Confidential V440 Server was des
42. array whether internal or external The primary objective is to maintain accessibility to data even in the event of a hardware failure of the controller or cabling etc Multipathing may offer higher throughput and bandwidth to the disk array but generally this is considered as a secondary advantage Within a storage logical unit RAID techniques may be applied for the purpose of masking the failure of an individual disk Typically RAID 5 striping with distributed parity is more effective than RAID 1 mirroring or complete duplicate copies Multipathing to the Internal Storage Array Not available however the internal dual channel controller an LSI 1030 chip offers the ability for HW mirroring Multipathing to External Arrays with dual channel controller When implementing multipathing to external arrays with the dual channel internal controller one channel is dedicated to the external SCSI connector In most cases the second path may be utilized via the X6758A Dual Channel LVD Ultral60 SCSI Host Bus Adapter However the Sun StorEdge 3310 JBOD requires two X6758A HBA s since the external SCSI port is not a supported configuration with this storage device Support through the external SCSI port for the Sun StorEdge 3310 JBOD is expected in late 2003 Software Requirements to Implement Multipathing In order for multipathing to be transparent to applications an intermediate software level is required to provide a layer of abstraction b
43. ber Description Reason Comments X6729A PCI to single FC AL Retired replaced by X6799A X6727A X2069A FCAL plus 1 Gbit Ethernet Uses older Qlogic 2100 series chip X1152A X1153A PCI to FDDI Retired no longer produced X1154A PCI to Token Ring Retired no longer produced X1156A Serial interface Retired replaced by X2156A X6542A SCSI RAID Controller Not supported approaching retirement X4810A PCI to OC 48 Packet over Sonet Adapter Apollo Retired not supported External Options The following external storage devices and arrays are supported Please refer to Network Storage configuration guidelines for specific details Disk Arrays Sun StorEdge 3310 SCSI Support is available via the X6758A Ultra3 SCSI HBA Sun StorEdge 3310 NAS Sun StorEdge 3120 Support expected Post GA Sun StorEdge 3510 Sun StorEdge A1000 D1000 Differential SCSI not supported via Sun Fire V440 external LVD SCSI connector HBA required Sun StorEdge D240 Sun StorEdge T3 enterprise array Sun StorEdge T3 workgroup array Sun StorEdge D2 Sun StorEdge S1 Sun StorEdge 6120 6320 Post GA Targeted for 12 03 Sun StorEdge 3900 Post GA Targeted for 12 03 Sun StorEdge 6900 Post GA Targeted for 12 03 Sun StorEdge 9900 Post GA Targeted for 12 03 Sun Fire V440 Server October 7 2003 Just the Facts 53 Sun Proprietary and Confidential Tape Drives and Tape Automation Current Sun StorEdge 4mm DDS 4 Unipack Sun StorEdge SDLT 320 De
44. ch USB Jazz and Zip drives and other supported products For additional networking connectivity or storage redundancy six PCI slots 3x33 MHz and 3x33 66 MHz all at 64 bits are available on the Sun Fire V440 server Sun Advanced Lights Out Manager ALOM Sun Advanced Lights Out Manager ALOM system controller is a secure server management tool that comes preinstalled on the Sun Fire V440 server It lets you monitor and control your server over a serial line or over a network The ALOM system controller provides remote system administration for geographically distributed or physically inaccessible systems You can connect to the ALOM system controller card using a local alphanumeric terminal a terminal server or a modem connected to its serial management port or over a network using its 10 BASE T network management port When you first power on the system the ALOM system controller card provides a default connection to the system console through its serial management port After initial setup you can assign an IP address to the network management port and connect the network management port to an ethernet network You can run diagnostic tests view diagnostic and error messages reboot your server and display environmental status information using the ALOM system controller software even if the operating system is down or the system is powered off The ALOM system controller can also send email alerts on hardware failures or other importa
45. ck Based System 6 85 174 mm Width 17 3 440 mm Depth Including 1 00 Bezel 125 0 635 mm Weight maximum 82 lbs 37 kg Environmental Specifications Power Requirements Minimum Configuration A42 XAB2 04GD calculated using base system with 1 PCI card Power at the following nominal line voltage 120VAC 60Hz 360W Typical Configuration A42 XAB4 08GD calculated using base system with 3 PCI cards Power at the following nominal line voltage 120VAC 60Hz 570W Maximum Configuration A42 XCB4 16GD calculated using base system with 6 PCI cards Power at the following nominal line voltage 120VAC 60Hz 650W Sun Fire V440 Server October 7 2003 Just the Facts Sun Proprietary and Confidential 27 All specifications below pertain to a fully configured system All specifications apply to operation at 50Hz or 60Hz Refers to total power input current required for both AC inlets when operating with dual power supplies or current required for a single AC inlet when operating with a single power supply Smaller configurations will consume less power Temperature Fahrenheit Celsius Operating 41 to 104 F 5 to 40 C Non operating 40 to 140 F 40 to 60 C Shock Shock IEC 60068 2 27 3 0G s 11 msec half sine 15 G s 11 msec half sine 1 inch roll off front to back 0 5 inch roll off side IEC 60068 2 6 amp 64 X Y axes 0 10
46. d Also optimizations for Java code VIS virtualization instruction set dramatically improves performance for graphics matrix operations etc by a factor of 2 3 While Intel processors can provide speeds in excess of 1 6 GHz today these are predominantly for single processor systems The servers depend upon the Xeon family which run at significantly slower speeds The architecture require for multiprocessors is much more complex i e to insure cache consistency Please note that HP and IBM RISC systems as well as Intel and AMD have all experienced delays with the introduction of faster processors Sun Fire V440 Server October 7 2003 Just the Facts 66 Sun Proprietary and Confidential The licensing fees for the operating systems are relatively comparable Counterpoint Windows 2000 Server supports e Up to a 4 way SMP system Upto4GB of memory An unlimited number of internet connections 1 995 license fee Windows 2000 Advanced Server supports e Up to an 8 way SMP system Upto 8 GB of memory A two node cluster An unlimited number of internet connections 5 995 license fee Windows 2000 Data Center supports e Up toa32 way SMP system Up to 64 GB of memory A four node cluster e Available and licensed ONLY through OEMs Windows NET Future e Up toa32 way SMP system Up to 64 GB of memory A four node cluster Where the Sun Fire V440 is the ideal solution The following are a list of marke
47. d Confidential Power Button The system Power button is recessed to prevent accidentally turning the system on or off The ability of the Power button to turn the system on or off is controlled by the system control keyswitch The ALOM system controller can also control the power on and power off functions if environmental conditions are out of specification or if the ALOM system controller detects that the system configuration card SCC is missing or invalid If the operating system is running pressing and releasing the Power button initiates a graceful software system shutdown Pressing and holding in the Power button for four seconds causes an immediate hardware shutdown CAUTION When possible use the graceful shutdown method Forcing an immediate hardware shutdown can cause disk drive corruption and loss of data Keyswitch The four position system control keyswitch on the front panel controls the power on modes of the system The system control keyswitch also prevents unauthorized users from powering off the system or reprogramming system firmware Famed Off SYSCTRL OFF Norral SYSCTRL NORMAL Locked SYSCTRL LOCKED o System antral Keyswitch s scT RL Power Button PWRBTN System Configuration Card SCC Diagnostics SYSCTRL DIAG DVD ROM Drive DVD Chalupa Server System Contol Area The following table describes the function of each system control keyswitch setting System Control
48. d temperatures to report and respond to any overtemperature or undertemperature conditions Additional I2C sensors detect component presence and component faults The hardware and software together ensure that the temperatures within the enclosure do not exceed predetermined safe operation ranges If the temperature observed by a sensor falls below a low temperature warning threshold or rises above a high temperature warning threshold the monitoring subsystem software lights the system Service Required LEDs on the front and back panels If the temperature condition persists and reaches a critical threshold the system initiates a graceful system shutdown In the event of a failure of the ALOM system controller backup sensors are used to protect the system from serious damage by initiating a forced hardware shutdown All error and warning messages are sent to the system console and logged in the var adm messages file Service Required LEDs remain lit after an automatic system shutdown to aid in problem diagnosis The monitoring subsystem is also designed to detect fan failures The system features integral power supply fans as well as two different fan assemblies If any fan or blower fails the monitoring subsystem detects the failure and generates an error message to the system console logs the message in the var adm messages file and lights the Service Required LEDs The power subsystem is monitored in a similar fashion Polling the power supp
49. desire compute intensive servers It offers scalability new technologies that improve speed and PCI slots for connecting to external storage Because of its low cost high performance dense packaging and memory scalability a group of Sun Fire V440 servers can be utilized to perfrom multiple specialized tasks eliminating the burden of attempting to use a large enterprise server for multiple tasks e Hot pluggable components such as disks and power supplies help maximize system availability by allowing maintenance and upgrades to occur during normal operations e Existing investments in non Sun hardware can be preserved by upgrading to Sun through competitive full system upgrades e Multiple Sun or non Sun hardware can be upgraded to a new Sun server by way of the server consolidation program How To Order An allowance code is used when upgrading to a Sun Fire V440 server Volume server Sun UAP product matrices containing standard upgrade allowance codes are included in the Sun Configuration guide The Sun UAP matrices provide instructions for using codes Sun Fire V440 Server October 7 2003 Just the Facts 55 Sun Proprietary and Confidential Allowance Code Numbering Scheme Standard Allowance Code ALW TBD S L A42 prea gt Product Family ETEA gt Residue Group gt Product Category T desktop D Disk S Server gt Percentage Allowance gt Every code will start with the letter ALW Allowance
50. e a new user is added Solaris Resource Manager software can keep rogue processes from running wild and consuming all the available processing power and virtual memory It also has the ability to vary resources based on previous usage It remembers how long ago a particular user logged on and what resources were used and can allocate fewer resources to a more active user so that even low priority users or applications receive enough resources Hierarchical Control Control can be as deep or shallow as desired For instance you can allocate shares to a department and then divide those shares among the individual users within the department In short Solaris Resource Manager software gives you greater flexibility in mapping resources to groups and individuals as needed Policy Based Administration Solaris Resource Manager software lets you configure limits for fixed resources It can control the number of processes number of logins and connect time Once you set a policy it is automatically enforced You can easily update the configuration at any time In fact you can use scripts to vary allocation based on time of day Resource Usage Tracking Solaris Resource Manager software provides detailed usage data that can be input through user defined tools or scripts into resource accounting or capacity planning programs Complementary Controls Solaris Resource Manager software complements the high availability features of Sun Cluster By leve
51. e in allowance towards the purchase of a 4 way Sun Fire V440 server Sun UAP simplifies the upgrades process by providing a trade in value as a percentage allowance This percentage allowance is applied to the list price of a new 4 way Sun Fire V440 system configuration Upgrades to the Sun Fire V440 server are available as a full system swap Customers can upgrade from an Ultra 5s 10s Enterprise 2 Enterprise 250 Enterprise 220R Enterprise 450 Enterprise 420R and Sun Fire 280R to the new Sun Fire V440 server However components such as CPUs memory and drives cannot migrate from UltraSPARC II or UltraSPARC III systems Sun Fire V440 uses UltraSPARC Ii technology Memory components such as the 512 MB and 1 GB memory options can migrate from UltraSPARC IIi systems like the Sun Fire V210 and Sun Fire V240 Systems being upgraded must be owned by used by and in the possession of the customer at least ninety 90 days prior to upgrading To qualify for the upgrade allowance customers must return within 90 days a bootable working system Key Messages The Sun Fire V440 Server is available in standard fixed configurations The Sun Fire V440 Server helps complete Sun s end to end architecture value chain that consists of low priced horizontal scaling machines to massive vertical scaling machines As the new four way server within the server product line the Sun Fire V440 will meet the needs of customers who
52. e is attached to the system s serial management port Sun Fire V440 Server October 7 2003 Just the Facts 32 Sun Proprietary and Confidential Product Documentation The documentation package includes a combination of printed and electronic technical information In print customers will receive Product Notes and a foldout poster size guide to installing the cable management system and instructions for powering on the system The system cover itself provides a label with a graphical representation of the rackmounting procedure The technical manuals are delivered on CD ROM in PDF and HTML formats The Documentation CD provides the system technical manuals for installation administration diagnostics and trouleshooting service and use of the Advanced Lights Out Manager software The manuals can be accessed in either PDF or HTML format using a convenient Graphical User Interface GUI The Documentation CD is usable on both Sun systems and PCs through commonly available browsers Additional features of the documentaion include translations of all manuals except the service manual into nine languages other than English Manuals in HTML format comply with the Section 508 Accessibility requirements for users with disabilities The Documentation CD supports searching for text across all appropriate PDF and HTML books in the document set In addition the service manual includes ShowMe How tm animations of certain service procedures Solar
53. em Other Options Rackmount Kit X7417A Two Post Rackmount kit 1 Video Monitors X7147A 17 inch entry color monitor X7137A 18 1 TFT LCD Color Monitor X7146A 21 inch color monitor 19 8 inch v a Note The following have been retired but are supported for PGX32 and PGX64 X1703A 17 inch entry color monitor X7119A 19 inch color monitor X7121A 21 inch color monitor SCSI Cables and Adapters X1139A 2 meter cable SCSI 68 pin Ultra SCSI supports StorEdge D240 PCI host bus adapter P N X1032A 10 100BASE T F W UltraSCSI X3830A 4 meter cable SCSI 68 pin to VHDC supports StorEdge D240 Compact PCI host bus adapter P N X1232A 2310 amp 1310 10 100BASE T F W UltraSCSD X3831A HD68 to VHDCI68 with Ferrites 10m StorEdge 2310 1310 X3832A HD68 to VHDCI68 with Ferrites 2m X3835A HD68M to 2xHD68F 30cm Y cable Sun Fire V440 Server October 7 2003 Just the Facts 51 Sun Proprietary and Confidential X1136A Cable SCSI VHDCI VHDCTI 0 8m StorEdge 2310 1310 X1137A Cable SCSI VHDCI VHDCTI 1 2m StorEdge 2310 1310 X1138A Cable SCSI VHDCI VHDCI 2m StorEdge 2310 1310 X3856A HD68 to HD68 with Ferrites 80m X3810A HD68 to HD68 with Ferrites 4m X3838A HD68 to HD68 with Ferrites 6m X3839A HD68 to HD68 with Ferrites 8m X905A HD68 ti HD68 1m 530 2224 HD68 to HD68 with Ferrites 1m X902A HD68 to HD68 with Ferri
54. emory modules all main memory is accessible from any processor over the system bus The main memory is logically shared by all processors and I O devices in the system However memory is managed and allocated by the CPU on its host module 1 e the DIMMs on CPU memory module 0 are managed by CPUO System I O is handled by four separate Peripheral Component Interconnect PCI buses These industry standard buses support all of the system s on board I O controllers in addition to six slots for PCI interface cards Three of the PCI slots operate at a 33 MHz clock rate and three slots operate at either 33 or 66 MHz All slots comply with PCI system Bus Specification Revision 2 2 Internal disk storage is provided by up to four 1 inch hot pluggable Small Computer System Interface SCSI disk drives The basic system includes a SCSI disk backplane that accommodates four 36GB or 73GB Ultra320 SCSI disks The system also supports external mass storage solutions with an external SCSI port located on the system s back panel External multidisk storage subsystems and redundant array of independent disks RAID storage arrays can be supported by installing single channel or multichannel PCI host adapter cards along with the appropriate system software Software drivers supporting SCSI and other types of devices are included in the Solaris operating system In addition the system supports internal hardware mirroring RAID 1 using an onboard LSI1030 Ultra320 SC
55. ent of an emergency Should the master KDC fail the read only replicated slave KDC still holds the necessary information for the authentication process to take place without interruption What s more if the master becomes unrecoverable customers can easily convert the replicated slave to be the new master Sun Fire V440 Server October 7 2003 Just the Facts 38 Sun Proprietary and Confidential e Faster performance Sun Enterprise Authentication Mechanism software is faster and more reliable because its replicated KDCs reduce contention for security verification from across the enterprise For example replicas may be created for use by different business divisions or remote offices Instead of competing for a single copy the division or office has its own copy Consequently access to secured applications becomes faster e Multiple realms Sun Enterprise Authentication Mechanism software supports multiple realms A realm is the set of users or servers registered with a specific KDC basically the scope of authentication for a given KDC Separating an enterprise into multiple realms enables SEAM software to operate across organizational boundaries and between different systems A client in one realm can be authenticated to a server in another SEAM software allows enterprises to isolate individual departments from each other decentralizing control to local network administrators For large corporations realms enable SEAM software to be c
56. erial port ttyb Four USB ports Two Gigabit Ethernet ports One Ultra320 SCSI port 1 1 Power Redundancy The system features two hot pluggable power supplies either of which is capable of handling the system s entire load Thus the two power supplies provide 1 1 redundancy enabling the system to continue operating should one of the power supplies or its AC power source fail NOTE Two power supplies must be present at all times to ensure proper system cooling Even if one power supply has failed its fans obtain power from the other power supply and through the motherboard to maintain proper system cooling Sun Fire V440 Server October 7 2003 Just the Facts 20 Sun Proprietary and Confidential System Configuration Card SCC Reader System Configuration Card System Control Keyswitch DVD ROM Drive The system configuration card SCC reader contains the system configuration card This plastic card stores the system s host ID Ethernet MAC addresses for all on board Ethernet devices OpenBootTM configuration variables and ALOM system controller user and system configuration data The card performs the same functions that were performed by the NVRAM module in previous Sun systems along with enhanced system controller support Using the SCC you can transfer this configuration data from one system to another CAUTION The system configuration card must be installed and in place at all times while the system is running
57. ers The majority of components are capable of being serviced without dismounting from the slides Power supplies and internal disk drives are front accessible The Sun DeLorean Rack SG XARYO030A may be used The Sun Serengeti Expansion Rack SF XCAB may also be used NOTE Both currently under review for fit and regulatory approval Other manufacturers of cabinets include but are not limited to Rittal www rittal com e Pentair www pentair ep com e APW Wrightline www wrightline com All offer four post cabinets that are 78 2 000 mm high and 32 or 36 800 or 900 mm deep None of these products have been tested and neither the companies nor the products are endorsed or supported by Sun Reliability Availability and Serviceability RAS Reliability availability and serviceability are three aspects of the design and quality of a system that contribute to continuous operation and consequently minimize system downtime e Reliability Reliability refers to a system s ability to operate continuously without failures and to maintain data integrity Reliability influences MTBF e Availability System availability measures the percentage of time that a system is accessible by users and is providing service Serviceability Serviceability measures the time to restore a system to operation once a failure has occurred Serviceability influences MTTR Various metrics may be applied in calculating RAS including MTB
58. erver This remote capability allows administrators to manage administrative and network services from home or virtually any other location without having to come to the network operation center when a trouble call comes in Solaris Management Console software makes Solaris Operating Environment administration easier by providing e Centralized administration current Solaris Operating Environment administration tools can be integrated and run from one location e Centralized management all servers on a network can be managed from a single console e Single login eliminates multiple logins into applications launched by Solaris Management Console software e Instant access to administration tools by running existing Solaris Operating Environment administration tools found in Solaris Easy Access Server software Solaris Management Console software also provides a set of wizards to simplify complex administration tasks DNS server configuration e DNS client configuration e Default router modification e Change root password e Network connection configuration e Shutdown restart computer Solaris Administration Wizards can be run from Solaris Management Console software or invoked via the command line The wizards make the Solaris Operating Environment easy to administer by providing a point and click Java technology based graphical user interface GUI for configuring Solaris systems Solaris Resource Manager Software Solaris Resource
59. etween the applications and the physical connectivity to the storage subsystem This layer can mask the failure of an individual loop from the application and redirect the I O over the alternate path All applications referencing the abstraction layer pick up the failover capability without having to deploy specific code for path selection and recovery Important If multipathing to an external array is desired a software manager such as Veritas Volume Manager with Dynamic Multipathing is required Failure to utilize a volume manager may result in the inadvertent corruption of the volume structure and or content resulting from the unsynchronized access via two independent paths to the same physical device To insure data integrity Veritas Volume Manager with Dynamic Multipathing must be implemented for multipathing to the external array Failure to do so will render the configuration unsupported However a second alternative is to utilize the Solaris 8 Multiplexing feature An unbundled enhancement after Solaris 8 7 01 referred to as Multiplexing I O MPxIO will provide multipathing to external arrays the Sun StorEdge A5x00 and Sun StorEdge T3 arrays via the X6799 or X6727 PCI adapters However this version will not offer support for the FC AL loops upon which the boot device resides i e most likely the internal storage array That functionality is planned for a subsequent version until which time Veritas Volume Manager with Dynamic Multipathing is requ
60. for other Solstice TMN software products such as Solstice Enterprise Manager software Solstice TMN Agent Toolkit Solstice TMN Agent Tester Solstice TMN SNMP Q Adaptor and Solstice TMNscript software Solstice CMIP software is the ideal solution for system integrators and telecommunications equipment manufacturers who want to develop CMIP based management applications for their products and to deploy these applications to their customer base Solstice CMIP software enables the development and deployment of TMN applications and is delivered as two related products The Solstice CMIP Standard Development Environment SDE is used to develop management applications that conform to the TMN management model Solstice CMIP Runtime RT is a standard implementation of the CMIP and the Common Management Information Service CMIS When it is combined with the SunLink OSI Communications Platform Solstice CMIP RT forms a TMN Q3 stack and supports any application developed using Solstice CMIP SDE Solstice DiskSuite Software Solstice DiskSuite software part of Solaris Easy Access Server is a disk and storage management solution for enterprise environments It provides high data availability and reliability delivers excellent I O performance and simplifies large system and disk administration With Solstice DiskSuite software customers get a powerful set of tools to enhance data availability Sun Fire V440 Server October 7 2003 Just the Facts
61. h TCP and UDP services SunScreen SPF software keeps track of the sequence of events that occur with a UDP service even though UDP is in fact a stateless protocol This is done to improve security and performance SunScreen SPF software allows flexibility in logging what has passed or failed through the screen Administrators can choose what they want to monitor and also be alerted to problems through alerts to network management stations To provide additional protection of the internal network network address translation NAT converts internal address to a different set of public addresses This also helps those customers that didn t formally register internal host IP addresses NAT supports both static and dynamic translation of internal addresses to public addresses Since hackers do not know internal addresses of hosts attacks are minimized Administration is done through secured remote administration stations enhancing security and meeting the needs of organizations for remote management VERITAS NetBackup Software VERITAS NetBackup software provides high performance industrial strength backup archive recovery and space management services for UNIX and PC clients in the large enterprise With high speed backup of large databases centralized management capabilities mainframe class media management and support for high end tape drives and robotics VERITAS NetBackup software is specially geared for the large data center customer V
62. h multiple consoles or users with ease e Multiple system support enables administrators to monitor manage all Solaris Operating Environment systems remotely e Predictive failure analysis enabling administrators to predict potential failures before they occur Health monitoring along with suggested steps for problem resolution resulting in simplified administration e Logical element grouping enabling Sun systems to be grouped by geographical location server role administrative responsibility among others e A comprehensive topology map providing a high level view of all the objects that are being managed along with hierarchies e Automatic discovery of Sun systems including IP address subnet address hostnames and more Event and alarm management providing administrators with the information they need when they need it Enterprise wide security measures such as authentication data integrity and access control lists for management of data and active management functions e Standard interfaces and protocols enabling integration with third party management tools including Tivoli Computer Associates and BMC e A Java technology interface providing heterogeneous GUI support a common look and feel for all Sun Management Center applications and the flexibility to manage the enterprise from any platform using Java technology SunScreen Secure Net Software SunScreen Secure Net software is a bundled solution which includes Su
63. he network management port to perform remote administration including externally initiated resets XIR Environmental Monitoring and Control The Sun Fire V440 server features an environmental monitoring subsystem designed to protect the server and its components against Extreme temperatures e Lack of adequate airflow through the system e Operating with missing or misconfigured components e Power supply failures Internal hardware faults Monitoring and control capabilities are handled by the ALOM system controller firmware This ensures that monitoring capabilities remain operational even if the system has halted or is unable to boot and without requiring the system to dedicate CPU and memory resources to monitor itself If the ALOM system controller fails the operating system reports the failure and takes over limited environmental monitoring and control functions Sun Fire V440 Server October 7 2003 Just the Facts 13 Sun Proprietary and Confidential The environmental monitoring subsystem uses an industry standard 12C bus The I2C bus is a simple two wire serial bus used throughout the system to allow the monitoring and control of temperature sensors fans power supplies status LEDs and the front panel system control keyswitch Temperature sensors are located throughout the system to monitor the operating temperature of the system and the CPU die temperature The monitoring subsystem polls each sensor and uses the sample
64. hen the ALOM system controller detects that the Solaris Operating Environment is running Power Supply LEDs Name Description Power supply OK to Remove This blue LED lights when it is safe to remove the power supply from the system Power Supply Service Required This amber LED lights when the system detects a fault in the monitored power supply Note that the Service Required LEDs on the front and back panel also light when this occurs Power supply DC This green LED lights when the power supply is on and outputting regulated power within OK specified limits Power supply AC This green LED lights whenever a proper AC voltage source is input to the power supply Present Hard Disk Drive LEDs Name Description OK to Remove This blue LED lights when it is safe to remove the hard disk drive from the system Service Required Reserved for future use Activity This green LED lights whenever a disk is present in the monitored drive slot This LED blinks slowly to indicate that the drive is spinning up or down and quickly to indicate disk activity NOTE Disk drives and Power supplies are hot pluggable However certain software preparations are required prior to removing or installing a drive or power supply Once the device is ready to be removed the Blue LED will light indicating it is safe to remove Sun Fire V440 Server Just the Facts October 7 2003 17 Sun Proprietary an
65. here price is one of the main buying criteria The Sun Fire V440 Server can be configured with from one to four processors running Solaris 8 HW 07 03 or later Processors run at 1 062 GHz or 1 28 GHz using industry standard DDR1 memory DIMM s added in pairs Each of the four CPU modules in a V440 system supports up to 4 DIMMs The V440 will support 512MB and 1GB DIMMs for a total system memory capacity of 16GB The Sun Fire V440 server also supports four internal 36 GB or 73 GB Ultra320 SCSI hard drives and six PCI slots connected to three high performance PCI I O buses The Sun Fire V440 server is designed to satisfy any application or enterprise where compute density at an affordable price is a high priority System main memory is provided by up to 16 DDR1 SDRAM DIMMs that operate at up to 133 MHz clock frequency Total system memory is shared by all CPUs in the system and ranges from a minimum of 2 GB one CPU Memory board with four 512MB DIMMs to a maximum of 16 GB four boards fully populated with 1GB DIMMs The Sun FireTM V440 server employs a shared memory multiprocessor architecture with all processors sharing the same physical address space The system processors main memory and I O subsystem communicate via a high speed system interconnect bus operating at a clock rate of up to 200 MHz In a system configured with multiple Sun Fire V440 Server October 7 2003 Just the Facts 1 Sun Proprietary and Confidential CPU m
66. igned as a general purpose workgroup server capable of meeting the needs of a wide range of industry applications users and environments This four way multiprocessor combined with a 2 3GB sec interconnect 1 MB of internal ECC protected cache dual GB Ethernet six available PCI slots integrated Ultra320 SCSI 320 MB sec disk subsystem and 16GB of memory capability ensures scalability in even the most compute intensive environments and applications Target Industries include Service Providers Financial Services and compute server markets as well as government utilities and retail Target Industries Target Markets Applications Financial Services e Equity trading OLTP on line banking e Insurance e Stock and commodity traders Banking Service Providers All aspects of internet capabilities including access web e Internet Service Providers hosting and supporting on line merchants and service e Network Providers providers i e order processing scheduling call center Portals tracking etc e Commerce Providers e Application Service Providers Manufacturing IT Finance and Accounting Human Resources ERP MRP Discrete manufacturing solutions Supply Chain management Engineering Sales amp e Process manufacturing Marketing Customer Service and Electronic Commerce Telecommunications and Internet Internet HTTP email FTP directory servers and electronic Services commerce and message switching Retai
67. ile system VxFS software augments UNIX file management with high availability increased bandwidth and up to date and reliable structural integrity It provides scalable performance and capacity to meet the demands of increased user loads and client server environments VxES software provides fast recovery following a system crash or reboot The system completes a file system check fsck in seconds regardless of file system size In addition VxFS software supports on line backup on line resizing shrinking and growing of a file system and on line defragmentation These capabilities allow administrators to respond to dynamic data capacity and performance requirements while reducing scheduled maintenance interruptions VxFS software allocates disk space to files in large contiguous areas called extents rather than in small fixed size blocks This results in a significant reduction in the number of I O operations required to read and write large amounts of data Performance Benchmarks Reference Benchmark information will be provided as it becomes available Sun Fire V440 Server October 7 2003 Just the Facts 43 Sun Proprietary and Confidential Ordering Information Standard Configurations Preconfigured Systems Standard configurations are a means to offer popularly configured systems These systems insure a functional base system via a single line item for the convenience of customers sales and operation manufacturing
68. included Memory Available 2GB 4 512MB DIMM 4GB configured as 4x1GB See Worldwide Functional 2GB for each 2 X7403A DIMM 2 X7404A Configuration Guide configured as CPU module or Sun Win 108142 4 512MB DIMM up to 4 total for standard trade in 2 X7403A groups of 4 allowances DIMMs Sun Fire V440 Server October 7 2003 Just the Facts 56 Sun Proprietary and Confidential Memory Configurations Please refer to details under the Section entitled Ordering Information Software Upgrade Ordering Order Number Title and Description SNM SM 2 2 3 P Solstice Site Manager e 2 2 3 CD Install Doc User Guide single system license Right to manage for 100 nodes in the network Solstice Cooperative Consoles 1 1 Sender SNM NM 2 2 3 P Solstice SunNet Manager e 2 2 3 CD Install Doc User Guide singe system license Right to manage unlimited number of nodes in the network Solstice Cooperative Consoles 1 1 Sender Sun Fire V440 Server October 7 2003 Just the Facts 57 Sun Proprietary and Confidential Service and Support The SunSpectrum program is an innovative and flexible service offering that allows customers to choose the level of service best suited to their needs ranging from mission critical support for maximum solution availability to backup assistance for self support customers The SunSpectrum program provides a simple pricing structure in which a single fee covers support for an entire system includ
69. ing System Storage The Sun Fire V440 server uses an intelligent two channel 320 MB sec Ultra320 SCSI controller Integrated into the motherboard the conroller resides on the PCI Bus 2B and supports a 64 bit 66MHz PCI interface The on board Ultra320 SCSI controller provides hardware RAID mirroring RAID 1 capability with higher performance than conventional software RAID mirroring One pair of hard disk drives can be mirrored using the on board Ultra320 SCSI controller Internal disk storage is provided by up to four 1 inch 2 54 cm high hot pluggable Small Computer System Interface SCSI disk drives The basic system includes an Ultra320 SCSI disk backplane that accommodates four 36GB or 73GB disks capable of data transfer rates of up to 320 MB sec MBps The system also supports external mass storage devices with an external SCSI port located on the system s back panel Internal and external SCSI devices are on independent buses providing better performance for both buses External multidisk storage subsystems and redundant array of independent disks RAID storage arrays can be supported by installing single port or dual port peripheral component interconnect PCI host adapter cards along with Sun Fire V440 Server October 7 2003 Just the Facts 11 Sun Proprietary and Confidential the appropriate system software Software drivers supporting SCSI and other types of devices are included in the Solaris operating system In additi
70. ing related hardware and peripherals the Solaris Operating Environment software and telephone support for Sun software packages The majority of Sun s customers today take advantage of the SunSpectrum program underscoring the value that it represents Customers should check with their local Sun Enterprise Services representatives for program and feature availability in their areas SUNSPECTRUM SUNSPECTRUM SUNSPECTRUM SUNSPECTRUM FEATURE PLATINUM GOLD l SILVER BRONZE Mission critical Business critical Systems Support Self Support Support Support Systems Features Systems approach coverage Yes Yes Yes Yes System availability Customized No No No guarantee Account Support Features Service account Yes No No No management team Local customer support No Yes No No management Personal technical Yes Yes Option No account support ServerStart No No No No Account support plan Yes Yes No No Software release planning Yes No No No On site account reviews Monthly Semiannual No No Skills assessment Yes No No No Site activity log Yes Yes No No Coverage Response Time Standard telephone 7 day 24 hour 7 day 24 hour 8 a m 8 p m 8 a m p m coverage hours Monday Friday Monday Friday Standard on site 7 day 24 hour 8 a m 8 p m 8 a m p m N A coverage hours Monday Friday Monday Friday 7 day 24 hour Yes Yes Option Option
71. ire http www sun com servers entry V 440 spec html V440 Server Internal Web Sites Internal Web Site for the Sun Fire http vsp east V440 Server Sun Fire V440 Server October 7 2003 Just the Facts 63 Sun Proprietary and Confidential Competitive Information Sun Fire Sun Fire HP DL580 Dell Power IBM HP IBM V440 V480 G2 Edge 6650 x360 rx5670 p630 Size 4RU 5 RU 4RU 4RU 3 RU 7RU 4RU Plus 2 expandable I O drawers Processor UltraSPAR UltraSPAR P4 2 0 P4 2 0 P4 2 0 Itanium2 64 bit power 4 Specs Ci C Ill Cu 2 5 2 8 Ghz 2 5 2 8 Ghz 2 5 2 8 Ghz 1 3GHz 1 2GHz 1 062GHz 900 1050 Xeon Xeon Xeon 1 4GHz and 1 45GHz 1 28 GHz 1200MHz 1 5GHz L1 on chip 32 KB 32 KB 12 KB 12 KB 12 KB 16KB 64KB cache instruction instruction instruction instruction instruction instruction instruction 32 64 KB data 64 KB data 8 KB data 8 KB data 8 KB data 16KB data KB data L2 cache 1MB on 8 MB 1MB 2 0 1MB 2 0 1MB 2 0 256KB L2 1 5 MB L2 Chip 1MB 2 5 1MB 2 5 1MB 2 5 1 5MB L3 or 8 32 MB L3 2MB 2 8 12MB 2 8 2MB 2 8 3 0MB L3 Maximum 4 4 4 4 4 4 4 CPUs Maximum 16GB 32 GB 32 GB 16 GB 8 GB 48 GB 32 GB Memory System 2 34 9 6 3 2 3 2 3 2 6 4 15 47 Bandwidth GB sec PCI slots 6 6 6 8 6 PCI X 10 4 6 PCI X 2 66 6 PCI X 7 PCI X 3 66MHZ MHz 64 bit 100MHz 100MHz ote 64 bit q f 6 66 MHz 64 bit MHz 64 b
72. ired Sun Fire V440 Server October 7 2003 Just the Facts 47 Sun Proprietary and Confidential RAID Implementation The Sun Fire V440 server offers RAID 1 Hardware Mirroring of the 4 internal Ultra320 SCSI disk drives via the internal dual channel LSI 1030 controller Hardware RAID 1 is an attractive enhancement that can boost overall I O throughput and performance as well as create a mirrored image of the internal drives for redundancy Software RAID may also be implemented on the internal storage array by either Solstice Disk Suite or Veritas Volume Manager with Dynamic Multipathing The Sun Fire V440 server requires a departmental Tier 1 license for Veritas Volume Manager Solistic Disk Suite is licensed with Solaris and provides e RAID 0 Striping RAID 1 Mirroring e RAID 1 0 Mirroring plus Striping e RAID 5 Striping with Distributed Parity e Dynamic File System Expansion UNIX File System Logging e Hot Disk Sparing Information is available under Solaris of which Solstice Disk Suite is a component Veritas Volume Manager with Dynamic Multipathing is licensed separately and provides e RAID 0 Striping RAID 1 Mirroring e RAID 0 1 Striping plus Mirroring e RAID 1 0 Mirroring plus Striping e RAID 5 Striping with Distributed Parity UNIX File System Logging provided separately by Veritas File System e Hot Disk Sparing USB Ports and Devices The system contains four USB 1 0a ports Sun Fi
73. is Bandwidth Manager Software Solaris Bandwidth Manager software available with Solaris ISP Server software allows the administrator to control the bandwidth assigned to particular applications users and departments that share the same Internet link By installing Solaris Bandwidth Manager software on their network s major links and application servers and by setting consistent policies customers can distribute bandwidth evenly Customers can prioritize traffic preventing a small number of applications or users from consuming all available bandwidth Solaris Bandwidth Manager software enables customers to e Provide differentiated classes of service to users and bill accordingly e Provide bandwidth to priority users applications or servers e Reduce traffic congestion and increase network efficiency e Control users and applications in their access to network resources e Gather detailed network use statistics and accounting data for usage based billing Solaris Bandwidth Manager enables network service providers to get the most out of their existing network resources It helps them to enable adequate levels of service to their customers and collect accurate accounting information for usage based billing Solaris Management Console Software Solaris Management Console software an integral component of Solaris Easy Access Server makes it easy for administrators to configure and administer Solaris Operating Environment systems Based on
74. it 1 33 MHz 64 bit 32 bit Internal Disk Integrated Integrated Integrated Integrated Integrated Integrated Integrated Controller Dual FC AL Ultral60 Ultra160 Ultra160 Dual Channel Ultral60 SCSI Channel Integrated SCSI SCSI SCSI Ultra320 SCSI Ultra320 Mulitipathi SCSI ng capability Internal Disks 4 SCSI 2 FC AL 4 SCSI 5 SCSI 3 SCSI 4 SCSI 4 SCSI Sun Fire V440 Server October 7 2003 Just the Facts 64 Sun Proprietary and Confidential Sun Fire Sun Fire HP DL580 Dell Power IBM HP IBM V440 V480 G2 Edge 6650 x360 rx5670 p630 T O Ports SCSI 2 1 FC AL 2 Iserial 1 lserial 2 2 serial 1 3 RS 232 3 serial 1 Gb NIC 2 1 Gb NIC network network parallel 1 serial 10 100 parallel 2 serial 4 1 RJ45 RJ 45 PS 2 RJ 45 PS 2 network BT and network USB serial 2 mouse mouse RJ 45 10 100 1000 keyboard USB keyboard keyboard mouse BT network 2 mouse 1 graphics 2 graphics 2 keyboard USB external SCSI USB USB 2 USB Ultra160 High Redundant Hot plug Hot plug Hot plug Hot plug Redundant Hot plug disks Availability 1 1 Hot disks amp disks amp disks amp disks amp hot swap amp power Options Plug power power power auto power auto power power and cooling auto Hot plug ASR RSC reboot reboot cooling fans hot plug reboot disks alternate remote remote auto reboot internal disks redundant ALOM path to monitor monitor redundant ECC memory cooling ASR of
75. ized access Through powerful authentication and single sign on capabilities SEAM software provides increased data privacy and integrity While firewalls are designed to fend off intruders from the outside they cannot address security incidents that originate from within Today growing evidence indicates that most security breaches start with people inside or known to the enterprise For true network security customers need to take steps to protect the company s valuable data resources from unauthorized access from both inside and outside the enterprise Sun Enterprise Authentication Mechanism software provides the extra layer of security customers need to protect the enterprise By combining centralized authentication with strong encryption SEAM software provides a more secure login process which helps customers to better protect their data privacy and integrity e Centralized authentication and management Sun Enterprise Authentication Mechanism software offers a single repository for enterprise authentication information called the Key Distribution Center KDC The KDC maintains a database of user server and password information Through that database SEAM software can authenticate users servers and applications Anyone and everyone attempting to access information must first be checked against the KDC database before being ticketed as an authenticated user Because security information is centralized SEAM software allows customers to m
76. l In store electronic retail systems merchandising systems inventory management distribution and electronic commerce CRM Government Branch office systems departmental servers repositories for e City municipal public works program documents and engineering plans State provincial financial records Federal national Healthcare Satellite office servers patient records billing claims e Hospitals and Clinics processing medical imaging systems picture archival and e HMOs and Managed Care Providers Munications systems e Medical equipment OEMs Education Registration and student records financial aid administration academic research Scientific Research Analysis Compute High performance applications MCAD EDA CFD Farms computational fluid dynamics simulation and modeling EDA statistical analysis scientific research departmental MCAD repositories Sun Fire V440 Server October 7 2003 Just the Facts 7 Sun Proprietary and Confidential Target Applications Applications Key Features to Highlight Database or Digital Media Management Outstanding storage connectivity with PCI card Exceptional network connectivity and I O bandwidth Distributed Database Access Outstanding network connectivity computing power network I O performance total system throughput Reliability and availability features Online Transaction Processing OLTP Balanced comp
77. linia datado 13 Environmental Monitoring and Control cee eseecssessessesseeeeceeeseesceseesessecaeeaeceeeseeaceseeseeseceesaecnaeseeaaeseens 13 Low Power COMSUMPtION seese eevee eaae nin ee OO EE ET chan tees soptaabe qocptawsoadbed ias ERESHE 14 Memory Subsystems a A A A A at A A 15 Automatic System Recovery ASR aesir tee e Tr a E aE oa aa a E rae iE 15 Front Panel Features o arrn eee E EER n ce A A AA a 15 Security LOCK oeae O NT 16 EED Status Indicators A rieo a ee o ee lae aia Ae A aE ed o RnS 16 Power ButlOMinaitlaiata id a E E EE E e Sud tases EEEE a E aaea 18 Keys WIth nini oi e det asp dr a ane heats 18 Back Panel Features ceci and E E EEE 20 T41 PO Wer RedUO dt A A A a 20 System Configuration Card SCC Reader ececessesssescesececeesecsecsaeceeesecesecsecseesecaaeeeecsecaeeaeeseceaeeaeenaeeaeeas 21 About Reliability Availability and Serviceability RAS FeatureS coocoocncncnocnnoncocononnnnnonc cnn nono cnnonnrncnncrnnns 21 Hot Plusgable Components as bcs di eee eE a AEL eva e ede vise ean AAD ee etal eee ess 22 Sun Fire TM V440 Block Diagram ee ennenen nerea eae ee aaa ea aa E a EE REEE 23 System Rack MOI IMOS ua ae e E E ea E EE E R E e E E eE E a ea 25 Reliability Availability Serviceability RAS eseseeeesesesseeseseseseseseesrsssssseeressesessnrsssserertstenenrseesesesertsrenenee 25 Installation Data ss 20 nenene tata iodo lts lbs 27 Hardware Dimensions 000 A a A AA 27 Environmental Specifications pionera 27
78. ly Fault detection and recovery ShowMe How Power On Self Test POST OpenBoot Diagnostics SunVTS Sun Management Center Sun Cluster Standard Standard Standard Standard Standard Licensed separately Upgrade administration ShowMe How Standard Management application development environments Sun Management Center Developers Environment Solaris WBEM Services Licensed separately Standard Sun Fire V440 Server Just the Facts October 7 2003 Sun Proprietary and Confidential 31 OpenBoot Diagnostics OpenBoot Diagnostics OBDiag reside in flash PROM on the server s main logic board OBDiag can isolate errors in the following system components e Main logic board e DVD drive e Disk drives e Any option card that contains on board self test capabilities OBDiag tests not only the main logic board but also its interfaces e PCI Ethernet e Serial e Keyboard mouse OBDiag displays detailed diagnostic and error messages on a system console or on a local terminal if one is attached to the system OBDiag tests run automatically when the system control keyswitch is placed in the diagnostics position or when enabled through OpenBoot firmware configuration variables Users can also run OBDiag interactively from the system OpenBoot monitor When users run OBDiag interactively they invoke the OBDiag menu which lets users select which tests they want to perform The system als
79. ly status periodically the monitoring subsystem indicates the status of each supply s DC outputs AC inputs and presence NOTE Two power supplies must be present at all times to ensure proper system cooling Even if one power supply has failed its fans obtain power from the other power supply and through the motherboard to maintain proper system cooling If a power supply problem is detected an error message is sent to the system console and logged in the var adm messages file Additionally LEDs located on each power supply light to indicate failures The system Service Required LED lights to indicate a system fault The ALOM system controller console alerts record power supply failures Low Power Consumption The low power consumption of the Sun Fire V440 server gives greater flexibility in high density rackmounting environments In today s deployment scenarios where costs are driven down by reducing the amount of external resources that servers need the Sun Fire V440 will be welcome because of its reduced power consumption and lower heat dissipation characteristics Sun Fire V440 Server October 7 2003 Just the Facts 14 Sun Proprietary and Confidential Memory Subsystems The Sun Fire V440 uses industry standard DDR1 Memory DIMMs Each of the four CPU modules in a Sun Fire V440 system can contain up to 4 DIMMs By using stacked DIMM technology the Sun Fire V440 will support up to 1GB DIMMs for a total system memor
80. mirroring RAID 1 e Support for disk and network multipathing with automatic failover capability Error correction and parity checking for improved data integrity e Easy access to all internal replaceable components e Full in rack serviceability for nearly all components Hot Pluggable Components The Sun Fire TM V440 hardware is designed to support hot plugging of internal disk drives and power supplies By using the proper software support you can install or remove these components while the system is running Hot plug technology significantly increases the system s serviceability and availability by providing the ability to e Increase storage capacity dynamically to handle larger work loads and improve system performance e Replace disk drives and power supplies without service disruption Sun Fire V440 Server October 7 2003 Just the Facts 22 Sun Proprietary and Confidential Sun Fire TM V440 Block Diagram SCSI Backplane UltraSPARCIIIi UltraSPARCIIIi pa Di Disk 1 SEEPROM Disk d Bell JBUS3 unused SCSI A x10 Ultra 4 SCSI gt NVSRAM SCSI B 53C1030 m 1BUS2 aan GEN m PCI 2B 66MHz Cassini Tomatillo 1 Tomatillo 0 PCI 1A 66MHz MC12429 Master Slave PROM SRAM RTC PCI 2A PCI 1H 66MHz 33MHz onsole SouthBridge Control PHY BCM 5421 IDE 0 1 3 2 4 5 RAE ip 33 33 33 66 66 66 A LA 0 1d Y USB PORTS Tryg DVD
81. n as volume shadowing or RAID 1 A higher availability option which provides two independent paths to storage and or networks An intermediate software layer is generally required to mask the failure of one path from the application When both paths are functional higher bandwidth and throughput is possible as a secondary benefit beyond higher availability Sun s distributed computing file system i e network file system Peripheral component interconnect An industry standard for connecting peripherals such as disk drives tape drives and other external devices October 7 2003 61 Sun Proprietary and Confidential Pre configured System PTO RAID Redundancy SCSI Standard Configuration Volume shadowing Sun Fire V440 Server Just the Facts Pre configured systems that offer discounted prices in comparison to assemble to order ATO or custom configurations It is also more convenient for both customers and sales as it assures that all necessary components for a functional system are included with a single line item on the order form Please see Pre configured System Redundant array of independent disks A set of disk drives that appear to be a single logical disk drive to an application such as a database or file system Different RAID levels provide different capacity performance high availability data protection and cost per unit of storage Reliability availability and serviceability Three aspects of the design
82. n is hot pluggable so that you can remove and replace a faulty power supply without shutting down the operating system or turning off the system power Some key applications are E mail services web serving Internet gateway search engines and encryption DNS HTTP and FTP services Sun Fire V440 Server October 7 2003 Just the Facts 2 Sun Proprietary and Confidential Financial services applications Database e On line transaction processing OLTP and electronic commerce Simulation and compute farms EDA e Government Applications Product Family Placement The Sun Fire V440 server is the latest member of the current volume server product family targeted at the entry market 4 way space with scalability from the low cost high performance two way Sun Fire 280R Sun Fire V210 Sun Fire V240 and up to the four way Sun Fire V480 and finally the eight way Sun Fire V880 These systems have several things in common including e The UltraSPARC processor family with 100 percent binary compatibility from the low end to the high end e Scalable from the low end uniprocessor systems to the 106 way Sun Fire 15K server e Modular easily replaceable components Server Target Users and Markets Sun Fire V210 and V240 Servers UltraSPARC III The Sun Fire V210 and V240 servers are entry data center class servers with high availability and expandability features Featuring up to two 1GHz UltraSPARC
83. nScreen EFS and SunScreen SKIP software It enables users to establish a secure business network SunScreen Secure Net software is a comprehensive security solution including one of the industry s fastest firewalls that builds on the power of the Solaris Operating Environment The customer can configure SunScreen Secure Net software to be a stealth box like the current SunScreen SPF 200 software including hardening the operating system Or the customer could select a few interfaces to be stealth and elect for other interfaces to be SunScreen EFS software interfaces thereby allowing for functionality such as proxies This gives SunScreen Secure Net software a unique capability of using stealth when connecting to untrusted networks for example the Internet while providing added functionality of proxies in other interfaces Sun Fire V440 Server October 7 2003 Just the Facts 40 Sun Proprietary and Confidential SunScreen SPF 200 Software SunScreen SPF 200 software is Sun s strongest platform for perimeter defense providing secure business operations over the Internet SunScreen SPF 200 software uses a stealth design to prevent attack and state of the art SunScreen SKIP encryption to protect data going over the network SunScreen SPF software s advanced dynamic packet filtering coupled with Sun s high speed hardware is designed to meet the most demanding performance requirements SunScreen EFS software was rated the fastest firew
84. nt events that can occur on the server Sun Fire V440 Server October 7 2003 Just the Facts 12 Sun Proprietary and Confidential The ALOM system controller provides the following features Default system console connection through its serial management port to an alphanumeric terminal terminal server or modem Network management port for remote monitoring and control over a network after initial setup e Remote system monitoring and error reporting including diagnostic output Remote reboot power on power off and reset functions e Ability to monitor system environmental conditions remotely e Ability to run diagnostic tests using a remote connection e Ability to remotely capture and store boot and run logs which you can review or replay later e Remote event notification for overtemperature conditions power supply faults system shutdown or system resets e Remote access to detailed event logs Serial Management Port The serial management port SERIAL MGT provides access to ALOM system controller functions and is the default connection to the system console All power on self test POST and ALOM system controller messages are directed to the serial management port by default Network Management Port The network management port NET MGT provides you with direct network access to the ALOM system controller card and its firmware as well as access to the system console and ALOM system controller messages You can use t
85. ntial Microsoft Netware Macintosh Lotus Oracle Sybase Intel Veritas Windows Linux HP UX and AIX are the respective trademarks of their owners UNIX is a registered trademark in the United States and other countries exclusively licensed through X Open Company Ltd Table of Contents sun Fire Y440 Server Posit nin Boris nl decada detona dada iio 1 o A OO 1 Product Family Placenta A AAA A A it 3 Features and Benelits tii o io ova 5 Key Features A Sie a A A A nee ee 5 Ayatlability of Product tit tii it AAA tit deta 6 Target Us AE E E T E tiara titres 6 Target Industrie Sispan aa ae EE P E AEE RERE Eaa T 7 Target Applications vi diia 8 Selling Hiehliehts caciones ate tias De paa 9 Market Value Propositions Gua A A id 9 Key MesSagesu uscar nti th ae ate Aue te a eee te 10 Enabling Technology rin A lens teaedocde we bento see i i i 11 UltraSPARC UG Microprocessors cesccsscssscesceseesecseeeceeceeseesaececaececeeaseseceaeeseeesesecaaeceeseeessecaaeeaeeeeeeecaaees 11 On Board Storages ndeoin n pe EER kis dela paisa 11 Memory Controller icon neea a e a e E iste hat inset beeen detect cee cs 12 System BUS iii a A 12 Networking sosis cicccs tees toctisestecttiets ep AEE EEA E ENE E EE sita ilatina 12 Sun Advanced Lights Out Manager ALOM sssssssesessesessssessrsesesesesesrrreststersresesereresresentnsstereeseseereseerssssses 12 Serial Management Porta a eS 13 Network Management Portman irra Dear uti eaten alentando
86. o provides configuration variables that users can set to affect the operation of the OBDiag tests OpenBoot Firmware The OpenBoot firmware is stored in the boot programmable read only memory PROM of the system It is executed immediately after the customer turns on the system The primary task of the OpenBoot firmware is to boot the operating system from either a mass storage device or from a network The firmware also provides extensive features for testing hardware and software interactively The OpenBoot firmware provides a command line interface for customers at the system console Customers can enter the OpenBoot environment by halting the operating system using the Stop A key sequence from the keyboard or by power cycling the system The OpenBoot device tree is a data structure that describes both the permanently installed and plug in devices attached to a system Both the user and the operating system can determine the hardware configuration of the system by inspecting the OpenBoot device tree Power On Self Test POST The POST diagnostic code resides in flash PROM on the system s main logic board It runs automatically when the system control keyswitch is placed in the diagnostics position or when enabled through OpenBoot firmware configuration variables POST tests the following system components e CPU modules e Memory modules e Main logic board POST displays detailed diagnostic and error messages on a local terminal if on
87. on the system supports internal hardware mirroring RAID 1 using the on board Ultra320 SCSI controller Memory Controller The memory controller integrated to each CPU controls the addressing and retrieving of memory data Memory is divided as local which is accessible by the CPU itself and foreign which has to be retrieved from the memory controlled by another CPU There is a minimal overhead when retrieving foreign data transactions because addressing and data transfers are realized in completely separate buses The supported memory is DDR 1 SDRAM PC2100 DIMM installed in 16 DIMM slots 4 per processor and they are divided in two banks of 2 equal size DIMMS The available capacity per DIMM slot will be 512MB and 1GB System Bus The system bus provides high throughput paths clocked at 177MHz when using the 1 062 GHz CPUs and at 183 MHz when the 1 28 GHz CPUs are installed The system bus is a memory coherent interconnect joining the four CPU modules and the two System J bus to PCI bus ASIC Bridges J Bus provides a memory coherent 128 bit shared address data path between each of the J Bus resident devices T O Interface The system provides two RJ 45 on board 10 100 1000Base T Gigabit Fast Ethernet ports for high throughput The system also provides a standard serial communication port ttyb through a DB 9 connector located on the back panel For additional storage capabilities four 12Mb s USB 1 0 ports are available to atta
88. on a disk and the creation of sparse non contiguous mirrors enabling the replication of critical disk areas SunVTS Software The Sun Validation Test Suite or SunVTS software is an online diagnostics tool and system exerciser for verifying the configuration and functionality of Sun hardware controllers devices and platforms SunVTS software is standard on the Solaris Supplemental CDROM Customers can run SunVTS software using any of these interfaces a command line interface a terminal interface or a graphical interface that runs within a windowed desktop environment SunVTS software lets customers view and control a testing session over modem lines or over a network Using a remote system customers can view the progress of a SunVTS testing session change testing options and control all testing features of another system on the network Sun Fire V440 Server October 7 2003 Just the Facts 42 Sun Proprietary and Confidential The SunVTS system exerciser is a graphically oriented UNIX application that permits the continuous exercising of system resources and internal and external peripheral equipment Used to determine if the system is functioning properly SunVTS software incorporates a multifunctional stress test of the system through operating system level calls and allows the addition of new tests as they become available VERITAS File System Software VERITAS File System VxFS software is a high performance quick recovery f
89. onfigured to allow administration at the local level A more secure environment Currently Sun Enterprise Authentication Mechanism software supports secure FTP NFS software Telnet and r commands These secure network services combined with strong encryption support enable the enterprise to preserve data privacy and data integrity by eliminating snooping around the network and tampering with data With SEAM software users can access files securely over the network e Interoperability Sun Enterprise Authentication Mechanism software is compliant with Internet RFC 1510 and RFC 1964 These RFCs define the Kerberos V5 protocols the de facto industry standard Through this standards compliance SEAM software allows enterprises to integrate with other vendors compliant security products e Cost effective Because Sun Enterprise Authentication Mechanism software is included in Solaris Easy Access Server software it offers feature rich security mechanisms with unlimited usage at a significantly lower cost than many third party solutions available today It requires fewer administrators because it is centrally managed enabling customers to lower the cost of securing their enterprise e Programmable security APIs Sun Enterprise Authentication Mechanism software allows ISVs to secure their applications by Remote Procedure Call API RPCSEC_GSS This API is an implementation of the RPCSEC_GSS security protocol defined in Internet RFC 2203
90. orized users Monitors the system memory and automatically configures around failed DIMMs or failed PCI cards Enhances availability by restoring system to operation as quickly as possible Minimizes the need for manual intervention Allows the easy transfer of the confguration data from one system to another for improved availability Monitors and reports system and component status Allows remote management via network or serial connection Reduces the overall cost of system management Enhances availability Facilitates resource sharing enables users to confirm proper initial system configuration and installation Provides full compatibility for binary applications across the UltraSPARC product line e Rack optimized chassis design provides modularity for flexibility maximum system growth and expansion potential Offers the flexibility of starting with 2 CPU modules and adding single modules later as compute needs grow Sun Fire V440 Server Just the Facts October 7 2003 Sun Proprietary and Confidential Provides memory capacity up to 16 GB maximum 4 slots per module using existing 1 GB DIMMs Supports 36GB or 73GB drive options supports 10K rpm and 15K rpm Ultra320 SCSI 320 MB sec disk drives Has expanded front access capabilities up to four hot plug disk drives power switch Atapi Slimline media bay for DVD ROM and up to two hot plug power supplies Allows for high I O expansion with six f
91. ourier Two day parts delivery N A N A N A Yes Overnight parts delivery N A N A N A Option Same day parts delivery Yes Yes Yes Option Remote Systems Diagnostics Remote dial in analysis Yes Yes Yes Yes Remote systems monitoring Yes Yes No No Remote predictive failure Yes Yes No No reporting Software Enhancements and Maintenance Releases Solaris Operating Yes Yes Yes Yes Environment enhancement releases Patches and maintenance Yes Yes Yes Yes releases Sun unbundled software Option Option Option Option enhancements Internet and CD ROM Support Tools SunSolve license Yes Yes Yes Yes SunSolve EarlyNotifier Yes Yes Yes Yes Service Sun Fire V440 Server October 7 2003 Just the Facts 59 Sun Proprietary and Confidential Support Services As the Sun Fire V440 assumes a bigger role in the data center there is an opportunity to enhance the level of service Customers may upgrade the warranty on the Sun Fire V440 to SunSpectrum Platinum Gold or Silver 1 Workgroup server installation services are available under part number WGSERVER INSTALL 2 Workgroup server rack installation services are available under part number SERVER INSTALL 3 Sun StorEdge Array Hardware Installation Order both of the following part numbers for each Sun StorEdge hardware only installation event ARRAY HW INS BASE2 Per tray charge Order in quantities of total number of disk trays being installed ARRAY HW PER TRAY 4 Sun StorEdge A
92. puters with a capacity of eight or fewer CPUs Please refer to www sun com software solaris binaries for more details and to register under this program Upgrades to Solaris 8 from Previous Versions Solaris 8 HW 07 03 or later is required for the Sun Fire V440 For customers who are running an earlier version of Solaris the Solaris Application Guarantee Program ensures that existing applications will run without modification on Solaris 8 Please refer to www sun com solaris programs guarantee for more details on this program Sun Fire V440 Server October 7 2003 Just the Facts 30 Sun Proprietary and Confidential System Management Information in this section changes frequently please go to www sun com for the latest information System Administration Built into the Solaris 8 Operating Environment are systems management and security features that will help deliver the computing environment demanded by customers Sun also offers unbundled systems management products that will supplement the systems management features in the Solaris 8 Operating Environment Together the Solaris 8 Operating Environment management features and Sun optional systems management products create one of the most stable and available computing environment in the industry Virtually any administrative task can be executed over a remote connection from any client by an authorized administrator And since a Solaris Operating Environment rarely req
93. r Ii processors four built in gigabit ethernet ports pre installed software a system configuration card advanced remote management and an optional integrated SSL card the Sun Fire V210 and V240 servers provide exceptional compute density network performance and Sun ONE software at affordable prices Sun Fire 280R Server 2 processor UltraSPARC II The Sun Fire 280R up to two 750MHz 900 MHz UltraSPARC III microprocessors extends the capabilities and performance of the UltraSPARC II based Sun Enterprise 220R The target customers for this server remain the same i e internet application network service providers and financial services Sun Fire V440 Server 4 processor UltraSPARC Ili The Sun Fire V440 utilizes an integrated processor architecture optimized to reduce cost and maintain performance The Sun Fire V440 represents a significant improvement in price performance relative to other competitive four way systems The Sun Fire V440 utilizes the UltraSPARC Ii processor which combines 1 MB of internal cache with processor speeds from 1 062GHz to 1 28GHz and up to 16GB of system memory in a compact 4RU package Thus providing maximized CPU processing memory density per square foot of floor space Sun Fire V480 Server 4 processor UltraSPARC II Designed to provide the ultimate compute density at an affordable price With the 900 MHz UltraSPARC III processor with 8 MB of ECC protected extern
94. raging the power of the Solaris Operating Environment Sun Cluster software delivers high availability in mission critical environments helping ensure that applications and services are available when needed With Solaris Resource Manager software more efficient utilization of resources helps provide predictable application performance in highly available Sun Cluster environments Solaris Resource Manager software augments Dynamic System Domains on the Sun Enterprise 10000 and Sun Fire tm servers Domains offer the ability to provide separate instances of the OS for each application or set of applications These domains can increase or decrease in capacity based on changes in processor load With Solaris Resource Manager resources can be even more finely tuned for each domain Solaris WBEM Services Part of the Solaris Easy Access Server Solaris WBEM Services makes the Solaris Operating Environment manageable by tools from other enterprise management vendors It also allows Solaris software tools to manage existing heterogeneous networks This is because WBEM is compatible with existing major protocols such as Simple Network Management Protocol SNMP Desktop Management Interface DMI and Common Management Information Protocol CMIP Developers can write WBEM agents or providers to convert information from these protocols to the CIM schema Solaris WBEM Services contains a set of tools Sun WBEM SDK and services to make it easier for software
95. re V440 Server October 7 2003 Just the Facts 48 Sun Proprietary and Confidential Options Supported Options Note The prefix X indicates availability strictly as a field installable option Maximum Order Number Option Description Bumper Comments Supported per System Processor Memory Modules X7415A 1 062 GHz UltraSPARC IIli processor memory 4 module processor with 1 MB internal L2 cache 2GB DDR1 4 x 512MB of memory included X7416A 1 28 GHz UltraSPARC Illi processor memory 4 module processor with 1 MB internal L2 cache 4GB DDR1 4x 1 GB of memory included Memory X7403A 1 GB 2 DIMMs of 512 MB each 8 Sets 4 DIMMs per module available as 2 Pairs per module X7404A 2 GB 2 DIMMs of 1 GB each 8 Sets 4 DIMMs per module available as 2 Pairs per module Internal Storage Devices X5261A 36 GB 1 0 10 000 RPM Ultra320 SCSI 320 MB sec 4 X5264A 73 GB 1 0 10 000 RPM Ultra320 SCSI 320 MB sec 4 External Storage Interfaces Sun Fire TM V440 server has 6 full size PCI expansion slots 3 slots 64bit 33Mhz 3 slots 64bit 66Mhz The total power consumption by PCI should not exceed 90W PCI SCSI Adapters X6540A Dual channel Single ended Ultra Wide SCSI PCI Adapter 4 X6541A Dual channel Differential Ultra Wide SCSI PCI Adapter 4 X6758A Dual Channel LVD Ultra160 SCSI HBA Jasper Jasper LVD 160MB sec HBA 4 PCI Fibre Channel Adapters Sun Fi
96. re V440 Server October 7 2003 Just the Facts 49 Sun Proprietary and Confidential X6768A Sun Dual Loop PCI FC AL 2GB host adapter Crystal 2 A GA June July 02 4 X6799A Sun Single Loop PCI FC AL Host Adapter Amber 4 X6767A Sun 2GB Single Fibre Channel Network Adapter Amber2 4 X6727A Sun Dual Loop PCI FC AL Host Adapter Crystal when released 4 SG XPCI1FC JF2 JNI 2Gb PCI Single FC HBA w SFK Amber 2 2J SG XPCI2FC JF2 JNI 2Gb PCI Dual FC HBA w SFK Crystal 2J 2 NOTE The X 6729A PCI to single FC AL controller is not supported in UltraSPARC Ili systems Network Interfaces PCI Serial Adapters X1155A Sun HSI P high speed serial interface PCI 4 X2156A Sun SAI P serial asynchronous interface PCI 4 P 0005 Mfg Antares Asychronous serial modem PCI 2 P 0002 Mfg Antares PCI SE 2 dual serial comm 2 PCI Ethernet Adapters X1033A EOL Q2FY03 6 X1034A 10 100 Base T Quad Fast Ethernet PCI Adapter 4 X1141A Gigabit Ethernet PCI Adapter 2 X1150A Sun Gigabit Ethernet Cat5 copper PCI66 adapter 2 X1151A Sun Gigaswift Ethernet PCI adapter Fiber 2 X4444A March 04 QGE GA March 04 Support expected 2 PCI to ATM Adapters X1157A EOL Q4FY04 Sun ATM 155 MMF 4 0 5 0 PCI66 bus adapter 4 X1158A EOL Q4FY04 Sun ATM 155 UTP 4 0 5 0 PCI66 bus adapter 4 X1159A EOL Q4FY04 Sun ATM 155 P622 MMF 4 0 5 0 PCI66 bus 3 adapter P
97. rformance in a Compact Footprint The Sun Fire V440 server is the latest member of Sun s powerful line of servers for enterprise network computing based on the UltraSPARC Hli processor technology This next generation volume server brings multiprocessing power Ultra320 SCSI disk drives and the industry standard Peripheral Component Interconnect PCI I O bus to a rack optimized 4RU rack unit design A standard 72 height Sun StorEdge rack contains 36 usable rack units and will fit up to 9 Sun Fire V440 servers however power and cooling requirements must also be considered In addition the Sun Fire V440 server delivers outstanding performance that users expect from Sun servers while at the same time preserving 100 percent SPARC Solaris binary compatibility with application software The Sun Fire V440 server gives customers the flexibility to scale their processing needs without wasting precious space making it an ideal server for service providers including ISPs and ASPs the Financial Services sector or anyone that requires a maximized CPU processing memory density per square foot of floor space In addition many of these customers choose to scale horizontally require the flexibility of attaching external storage via PCI expansion and demand that our products help minimize single points of failure by supplying enhanced server management software and tools The Sun Fire V440 server is intended for cost sensitive applications w
98. rrayStart Order both of the following part numbers for each Sun StorEdge ArrayStart installation event ARRAY INS BAS2 Per tray charge Order in quantities of total number of disk trays being installed ARRAY INS PER TRAY Warranty The standard warranty for the Sun Fire V440 server is three year Next Business Day on site response A 90 day software SunSpectrum program warranty is available Education Contact the local Sun representative Sun Fire V440 Server October 7 2003 Just the Facts 60 Sun Proprietary and Confidential Glossary 100BASE T Adapter ASR Controller DIMM DIMM group ECC Fast Ethernet Fault resilience Fault tolerance FC AL I2C High availability Host bus adapter Hot plug Mirroring Multipathing NFS PCI Sun Fire V440 Server Just the Facts See Fast Ethernet A host bus adapter or interface which plugs into a PCI slot to provide connectivity i e to networks storage graphics or other I O devices Automatic System Recovery A RAS feature that initiates a system reboot sequence that bypasses failed system components or a software failure A microprocessor based device which is dedicated to a specific task esp I O and is embeddded within a host bus adapter or external storage array The term controller is often used synonymously with host bus adapter Dual in line memory module A memory unit that is available in a range of capacities of 5
99. seesaeseceesseeaaeseesaeeeeeees 34 Solaris WBEM Services acicate it ale clsaah Wea weeean 35 Solaris Web Start SOLwares ti edt a ce eden EE a EE tes 36 Solaris Web Start Wizards Software eeessssceceeeseeecsecseeseceesececeseseeseesecaseaeceeeseeasseeaeenseseceeaeeaseasaes 36 Solstice EMIP Soltw aero iaa 36 Solstice DiskSuite SOlMtware iniciando li ibas 36 Sun Cluster SOM Ware it nen latido trillado insolito eds 37 Sun Enterprise Authentication Mechanism SEAM SoftWal8 occocococococonnconncononononnnnnoconono nono conccnno conan 38 Sun Management Center Software ecsesecsesseesesseeecsseeeeseeseescesececeseesseesecnsesecaeeaeeaesaesecsaseaeneeaecnseaees 39 SunScreen Secure Net SoftWare wuesen a ita ariete cnn daa cun EEEE E E E i 40 Sunscreen SPF 200 SoftWare ratita tota 41 VERITAS NetBackup SOL are nissenana ennonn eaaeo a ata ERE Nea E RIA CESARA ii 41 Sun StorEdge Instant Image Software sessesesesesessssssesesssseeesssssessssessssteeensssssessesessestenessssessesesseseenesssss 42 Sun StorEdge LiDMON Softwaren rniii e aiai Niii i ae ENES a ei 42 VERITAS Volume Manager VxVM Software sssssessssessesssssssssesesesssessesssseseessssesesnsssesnensesessesseseesssss 42 SUNV TS Software see o A e EEE AEE E N AEA N E Sue E E AEA Sead see 43 VERITAS File Systemi S oftware erica eeen aaa aaa e aeaa aeee eean ei ins reini 43 Performance Benchmarks Reference essesesesssesessrerertresrsrsrssrsrseseststststentetetsesseseseresreeen
100. sktop Tape Drive Sun StorEdge LTO 2 Desktop Tape Drive Not supported via Sun Fire V440 external SCSI connector Requires X6758A Ultra3 SCSI HBA Sun StorEdge L8 Tape Autoloader Not supported via Sun Fire V440 external SCSI connector Requires X6758A Ultra3 SCSI HBA Sun StorEdge L Tape Autoloader Not supported via Sun Fire V440 external SCSI connector Requires X6758A Ultra3 SCSI HBA Sun StorEdge L25 LVD versions Not supported via Sun Fire V440 external SCSI connector Requires X6758A Ultra3 SCSI HBA Sun StorEdge L100 LVD versions Not supported via Sun Fire V440 external SCSI connector Requires X6758A Ultra3 SCSI HBA Transitioned Sun StorEdge DLT8000 Flexipack Sun StorEdge SDLT 220 Desktop Tape Drive Sun StorEdge L7 Tape Autoloader Tape Library Calculator http rmqual ebay TLC TLC html Tape Automation Products At A Glance http webhome ebay networkstorage products tape_automation index html Sun Fire V440 Server October 7 2003 Just the Facts 54 Sun Proprietary and Confidential Upgrades Sun Upgrade Advantage Program UAP The Sun Fire V440 server is the newest member of Sun s powerful generation of Volume servers for enterprise network computing based upon the UltraSPARC IIi microprocessor technology From branch office or data center Sun provides upgrade solutions customers can count on to maximize their investment The Sun Upgrade Advantage program allows customers to receive a fair trad
101. sponsiveness they need when they need it Server Consolidation Solaris Resource Manager achieves the long sought goal of server consolidation Enterprise Applications hosting multiple applications on a single system is simpler and more cost effective than one application per system For example multiple ERP modules and database instances can be hosted on the same system that serves as a file and Web server Web Site Hosting Instead of purchasing large numbers of small servers Internet service providers Sun Fire V440 Server October 7 2003 Just the Facts 34 Sun Proprietary and Confidential or corporations that host their own Web sites can locate hundreds of Web servers on a single easy to maintain machine By managing resources each customer or department receives the resources that they have purchased Resource Utilization and Allocation Traditionally servers have been configured to handle average utilization of 20 30 percent with peaks planned for 75 percent Solaris Resource Manager on the other hand lets you make full use of your resources reducing overall costs Solaris Resource Manager software is based on the concept of the fair share scheduler where CPU resources are based on shares As users log in or out it automatically recalculates the proportion of resources allocated to each active user Compare that to percentage based allocation schemes that require the system administrator to reallocate percentages every tim
102. storage cooling memory Remote and PCD monitor ECC memory O S Solaris 8 Solaris 8 Windows Windows Windows HP UX 111 AIX 4 3 3 2000 2000 2000 Linux Linux Linux Linux Linux Windows AS 64 bit 4 way Xeon rack based systems Sun Fire V440 Advantages Platform SPARC Solaris from smallest configuration to largest Supports more memory Shallow chassis depth Most 4 way xeon systems products are limited to 8GB of memory due to hardware constraints but the few that are capable have large OS costs to extend beyond the 8GB Sparc and Solaris supports configurations from smallest to largest 4 way Itanium rack based systems Sun Fire V440 Advantages Power and cooling is lower than Itanium servers Lower Pricing in all configurations System chassis only 24 depth compared to 30 depth Integrated Dual 10 100 1000 Mb s Ethernet Platform SPARC Solaris from smallest configuration to largest Large number of applications written on Solaris Itanium is still in its infancy and lacks the OS and application support compared to SPARC Solaris Sun Fire V440 Server Just the Facts October 7 2003 Sun Proprietary and Confidential 65 The Itanium systems also require more power and cooling in a much larger footprint and at higher prices than Cherrystone It will still be some time before the risks of changing h w OS and Apps may even potentially be compelling IBM p630 Sun
103. t Panel Features Sun Fire V440 Server October 7 2003 Just the Facts 15 Sun Proprietary and Confidential Top cover lockdown SCC reader Power button System control System status LEDs keyswitch DVD ROM Disk drive 3 Disk drive 2 Disk drive 1 Disk drive O PESO E ARAALE TN Power su 1 Disk drive status LEDe pply Power supply 0 Power supply status LEDs Security Lock A front panel security lock secures the system doors and the top cover The system doors can be locked with one of the three keys supplied with the system The system doors can also be locked with the supplied mini key remaining in the system control keyswitch LED Status Indicators Several LED status indicators on both the front and back panels provide general system status alert you to system problems and help you to determine the location of system faults At the top left of the system as you look at its front are three general system LEDs Two of these LEDs the system Fault LED and the System Activity LED provide a snapshot of the overall system status One LED the Locator LED helps you to locate a specific system quickly even though it may be one of dozens or even scores of systems in a room The front panel Locator LED is at the far left in the cluster Other LEDs located on the front of the system work in conjunction with specific fault LED icons For example a power supply fault illuminates the associated power supply fault LED Since
104. t requirements that the the Sun Fire V440 product was designed to achieve e Rack optimized to maximize CPU density per footprint e Overall system performance optimization CPU 1 06 1 28GHz w 1MB internal cache Memory up to 16 GB VO 6 PCI slots Networking two 10 100 1000 Mb s Etherent RAS features Hot pluggable power supplies and disks ALOM ASR Excellent features and form factor for Data center customers Key Features to Highlight Price and Price Performance TCO Availability Rackable 4RU processor dense form factor High memory capacity Sun Fire V440 Server October 7 2003 Just the Facts 67 Sun Proprietary and Confidential Compact design 24 inch depth Reliability and serviceability Availability of applications Connectivity to external storage Where the Sun Fire V440 is not the ideal solution Where internal storage capacity is the highest priority and a requirement Scalability greater than 4 processors Domains highest levels of availability Sun Fire V440 Server October 7 2003 Just the Facts Sun Proprietary and Confidential 68
105. tage Program UAP ccoononinnicnonocononannnonnnncnnnnncnnccnnonc cono nono nonnon anna cnn rn anar nn cnc cono nan cn nern anno 55 Key Messages inicia A ia ch I ls ia 55 HOW PG Ordinal si ones lealgcevettet leave en aeea 55 Allowance Code Numbering Scheme ccc cescscessesceseesseseceeeceeeeecsacseeacescaecaesecseeaecaeeseenaeseesaeenesases 56 Upgtad Paths occiso bic ion coccion loader 56 Sun Fire V440 Server October 7 2003 Just the Facts 4 Sun Proprietary and Confidential Software Uperade Order tt at A a 57 Service IASUPPO Familiar dei Meester ete aia 58 Wal Vidas aida laa iodo tab babel T cit 60 Education a ee eke Re EE ER RES 60 Glosa iii laa dat llanta tops 61 Materials ADS IAE ES CAE OCIO AAA Ltda 63 Competitive Information i e ic soedes cocinando cido aidiccebes tag eazeccs sandgussnsdlsidaveageseadesuee PEEKE RAE ES EEEE E aacha Ea ieia 64 Point Counterpointy waicnci casi Metin ee ee dee wel ayes aaah tel edited ise ale 67 Where the Sun Fire V440 is the Ideal Soluti0N ocoococn nonccoconnnncccnnnnonanoninananonocanoncncnnnnnnnccncononaconano nono naaa nacos 68 Where the Sun Fire V440 is not the Ideal SolutiON ooooononccnnonaccnnonnnonnnnncnnnonononanonnonn canon nnnccnn ano conan conca nncnns 68 Sun Fire V440 Server October 7 2003 5 Just the Facts Sun Proprietary and Confidential Sun Fire V440 Server Positioning Figure 1 Sun Fire V440 Server front view Introduction Exceptional Price Pe
106. tes 2m 530 1883 HD68 ti HD68 20cm X9TIA HD68 ti HD68 25cm X901A HD68 to HD68 with Ferrites 80cm X9T9A HD68 ti HD68 12m 530 2375 HD68 to HD68 with Ferrites 12m 530 2452 HD68 to VHDCI68 with Ferrites 80cm X991A 90 HD68 to 90 HD68 16cm X992A Left 90 HD68 to 90 VHDCI68 2m X993A Left 90 HD68 to 90 VHDCI68 4m 370 3545 L1000 90 HD68 to 90 HD68 18cm 370 3456 L1000 90 HD68 to 90 HD68 36cm Fibre Cables X973A Fiber Optic Cable 2m X978A Fiber Optic Cable 15m X9732A 2M LC to LC Fibre Optical Cable Minnow 2U FC X9733A 5M LC to LC Fibre Optical Cable Minnow 2U FC X9734A 15M LC to LC Fibre Optical Cable Minnow 2U FC X9721A 0 4 meter LC to SC Fibre Channel Optic Cable X9722A 2 0 meter LC to SC Fibre Channel Optic Cable X9723A 5 0 meter LC to SC Fibre Channel Optic Cable X9724A 15 meter LC to SC Fibre Channel Optic Cable Racks SG XARY030A 72 inch Sun StorEdge expansion cabinet deLorean Rack SF XCAB Sun Fire Expansion Rack Serengeti SR9 XKLO38A Sun Rack 900 Sun Fire V440 Server October 7 2003 Just the Facts 32 Sun Proprietary and Confidential Additional PCI Adapters Other PCI adapters including those for ATM FDDI and Token Ring are available from T O Technologies Group http www sun com io Unsupported PCI Adapters The following is a partial listing of some of the recent PCI adapters that are not supported on the Sun Fire V440 server Part Num
107. tesssssssesesrsts 43 Ordering Informations sese sees eee A EE a E ia 44 Standard C nfig ratioNS isis te islas BEERE 44 Assemble to Order ConfIgULAtiONS oococcnocnnnnococnnnnononnconononnnoncnn co nonn conoce conan ana i anne cano near ana on non n riera R ia 45 Memory Configurations atun nas Weasels Au adele tae se cee dhe Beda iee eee 46 Expandability t 23 sctdy weet teh eee kien en ee ee aye ee hel Se ee 46 Storage Configuration Guidelines cece ecsseeseseseecsceseeseeseescseeeceacseesseseceseseeseesecesaesaeeasseesaeeecaessesaeeneceeeas 46 Host Bus Adapters iaa A si 46 Storage Configurations and SUpPOrt cece cseseesseeecseeeeceecseessesesseesecasseessescesaesecaeceesaeaesaeeaeeeceeeaseneeas 47 PC AL l0op8iisesctsseci eaa e sii elen isla eu ages bed we ie i ae ee See el 47 Multipathing atid Benelli amiooinoles oido till dsd tii apaina 47 Multipathing to the Internal Storage Array with dual controllers oonnonninncciocnnnnonorononnnrencanncnnn 47 Multipathing to External Arrays with dual controllers ooncniononncnonnocnnnnenennocnnranecnro ron ncnncnnonncnccnnono 47 Software Requirements to Implement Multipathing ee seecccsseeeceecseeseeececnseseceesseeseeasseesaeeeceeeaees 47 RAID Implementation 48 USB Ports and Devices carino a ia 48 OPUONS EN 49 Unsupported PCL Adapters covonininmna ill ie 53 Disk AtraYS curtir pts isa 53 Fapes and Tape LID iii A a ios 54 Une A added reo oia 55 Sun Upgrade Advan
108. ting Environment Key features of Sun Cluster software include support for Solaris 2 6 and 8 Operating Environment up to four clustered nodes from Sun s entire line of servers failover agents for key applications and a unified clustering foundation for standard and parallel applications Highlights include the following e Cluster up to eight servers to meet the needs of any workgroup department or data center e Run both standard and parallel applications on the same cluster e Dynamically add nodes e Manage the cluster through the easy to use Sun Cluster Management Console e Fault management API to customize applications for high availability e Individual application failover local application restart and local network adaptor failover for fast recovery Sun Fire V440 Server October 7 2003 Just the Facts 37 Sun Proprietary and Confidential High speed cluster interconnects and high bandwidth networking deliver exceptional throughput The Sun Fire V440 server supports Sun Cluster 3 0 and includes support for the following storage arrays SunStorEdge 3310 Sun StorEdge T3 Sun StorEdge A1000 Please refer to www sun com software cluster for additional information Sun Enterprise Authentication Mechanism SEAM Software Sun Enterprise Authentication Mechanism SEAM software a component of Solaris Easy Access Server software delivers an extra layer of security inside the firewall to protect the enterprise from unauthor
109. uires rebooting administrators will not lose their network connection when adding new software or reconfiguring the system Solaris Operating Environment applications can be installed or upgraded on a Solaris server without affecting users and without disabling the network services running on that computer Standard or Licensed Separately Management Function Sun Management Tools SunScreen Secure Net SunScreen SPF 200 System installation Sun OpenBoot firmware Standard software installation Solaris Web Start and Solaris Web Start Wizards e Standard System configuration Solaris Management Console Standard Advanced Lights Out Manager ALOM e Standard User administration Solaris Management Console Standard Advanced Lights Out Manager ALOM Standard Security management Sun Enterprise Authentication Mechanism Standard Licensed separately Licensed separately Storage management Solstice DiskSuite VERITAS Volume Manager VERITAS File System Sun StorEdge LibMON VERITAS NetBackup Sun StorEdge Instant Image Standard Licensed separately Licensed separately Licensed separately Licensed separately Licensed separately System monitoring Solaris Management Console Sun Management Center basic feature set Advanced Lights Out Manager ALOM Standard Standard Standard Tuning resource and performance management Solaris Resource Manager Licensed separate
110. ull length industry standard PCI bus slots 3 2 66MHz 3 33MHz High performance low cost UltraSsPARC IIi Processors 64 bit SPARC architecture running at 1 062GHz and 1 28GHz 1 MB of ECC protected internal L2 cache per processor Binary compatibility with previous SPARC processors thereby providing ease of migration for existing applications SCC System Configuration Card increases availabilty by permiting system identity to be transferred top stand by systems ALOM simplifies management of servers reducing cost and complexity in horizontal scaling environments TCO Data Center friendly server with low power and cooling requirements at an attractive price Offers 1 to 4 way multiprocessing system based upon single processor memory modules Integrated Ultra320 SCSI 320 MB sec disk subsystem with capacity for four 36 GB or 73 GB disks including HW Raid Mirroring Integrated Controllers Integrated dual channel SCSI disk controller two 10 100 1000 Mb s Ethernet ports RJ 45 serial and four USB ports Saves PCI slots for user selectable controllers Cost effective familiar to those from the PC environment VO Subsystem 1 84 GB sec throughput capability All I O is distributed across four PCI buses The PCI cards are distributed across three independent PCI buses to minimize contention among controllers and maximize processing capabilities with the fourth reserved for Ethernet and Internal disks PCI buses
111. ure e 1 1 power with separate power cords e Dual Gigabit Ethernet interfaces and up to 16GB of memory e 6 PCI slots 3 at 66 MHz 64 bit wide and 3 at 33 MHz 64 bit wide across three PCI buses Hot plug disks and hot plug power supplies e Diagnostics and Security e Automatic System Recovery ASR e System Configuration Card SCC e Advanced Lights Out Manager ALOM e SunCluster Install Checker e Solaris 8 Key Features Benefits e UltraSPARC III technology offers better scalability and enhanced performance as compared to previous generations of processors This enclosure offers high compute density giving customers maximum value per rack unit A fully configured system can operate on one power supply the second power supply is for redundancy and load balancing Enhances system availability by masking an individual AC circuit failure Excellent I O performance and memory capacity makes the Sun Fire V440 server an excellent web e commerce or EDA server Allows users to configure systems according to their needs with additional network storage graphics adapters etc Eliminates contention among peripheral controllers thereby maximizing processing capabilities On line maintenance and repair enhances system availability Front and back LEDs for easy quick diagnosis of system state Physical security preventing access to enclosed hardware and preventing initiation of applications from unauth
112. utational and I O capacity Storage I O and Network I O performance Robust development environment Scalable operating system E mail Web Mail Services Internet Gateway Connectivity with heterogeneous systems and networks Exceptional scalable multithread performance Exceptional total system throughput Decision Support e Online analytical processing Scalable computing power Storage connectivity and I O performance Groupware Collaboration Lotus Notes Enterprise networking and PC inter operability Supports hundreds of UNIX or PC clients Internet e Internet Providers e Application Service Providers Secure reliable and cost effective Sun is the leading internet provider majority of the servers on the Internet are Sun servers Inter operability PC Netlink Compute Intensive ECAD CFD e Simulations Compute density 4RU 24 depth rack based system Large memory with low access latency High system bandwidth Scalability Capable of 4GB of memory per processor Sun Fire V440 Server Just the Facts October 7 2003 Sun Proprietary and Confidential Selling Highlights Market Value Proposition Sun Fire TM V440 Server will bring new UltraSPARC Ili technology to our customers in a four CPU rack optimized enclosure configuration Value Proposition 1 LOW solution costs the Sun Fire V440 server with its support for the reliable and secure Solaris Sun One software st
113. y capacity of 16GB Automatic System Recovery ASR The system provides for automatic system recovery ASR from component failures in memory modules and PCI cards The ASR features allow the system to resume operation after experiencing certain non fatal hardware faults or failures Automatic self test features enable the system to detect failed hardware components and an auto configuring capability designed into the system s boot firmware allows the system to deconfigure failed components and restore system operation As long as the system is capable of operating without the failed component the ASR features will enable the system to reboot automatically without operator intervention During the power on sequence if a faulty component is detected the component is effectively disabled and if the system remains capable of functioning the boot sequence continues In a running system some types of failures such as a memory module can bring down the system If this happens the ASR functionality enables the system to reboot immediately if it is possible for the system to run without the failed component This prevents a faulty hardware component from keeping the entire system down or causing the system to crash repeatedly NOTE ASR functionality is not enabled until you activate it Control over the system s ASR functionality is provided by a number of OpenBoot PROM commands and configuration variables Front Panel Features Figure 2 Fron