Home
P1 Rel 1.0 Software Release Notes
Contents
1. Console When a graphic is upgraded from V15R5 to V18R2 2 link objects for discrete 801260 registers for example 1A 10 a no longer animate in V18 Console The loop power module status bits on the field IO status screen for MAIO are D3 801615 displayed in the alarm color whenever they are 1 even if meaningless Console In the tuning display operation changing the scaling at the left of the faceplate 4 102845 does not change the alarm limit indication Console If the alarm log is not enabled or not defined a large number of Illegal 4 152623 Volume File Name Used alarms are generated Console When viewing the Disk Directory Peerway screen all drives are listed under the 4 152786 drive 1 position for several seconds Console When creating a boot tape the default New Volume Name can confuse Batch 801076 Console Process graphics with complex layering of windows might crash during periods of 4 801107 high alarm activity Console On the 68040 console block descriptors with 24 or more characters cause the 4 801310 console to crash Console Console crashed during printing of a report No alarms appeared 4 801323 Console If more than 32 consoles and SRUs are on linked PeerWays a console might not D4 801362 be able to access a process graphic on a different node Console Task neglected to restore rrow variable to its original value of zero causing crash 4 801376 dumps Console Variables of 10 or more characters from
2. FISHER ROSEMOUNT RS3 Software Release Notes Performance Series Release 1 May 1996 U S Manual PN 1984 2818 0110 Fisher Rosemount Systems Inc 1987 1996 All rights reserved Printed in the U S A Components of the RS3 distributed process control system may be protected by U S patent Nos 4 243 931 4 370 257 4 581 734 Other Patents Pending RS3 is a mark of one or more of the Fisher Rosemount group of companies All other marks are property of their respective owners The contents of this publication are presented for informational purposes only and while every effort has been made to ensure their accuracy they are not to be construed as warranties or guarantees express or implied regarding the products or services described herein or their use or applicability We reserve the right to modify or improve the designs or specifications of such products without notice Fisher Rosemount Systems Inc 12000 Portland Avenue South Burnsville Minnesota 55337 U S A Telephone 612 895 2000 TWX Telex 192177 FAX 612 895 2044 Comment Form RS3 Manuals Software Release Notes Please give us your feedback to help improve this manual Never Rarely Sometimes 1 Do you actually use this manual when you are configuring making changes or enhancements operating the system troubleshooting other 2 Does this manual answer your questions 3 What could be changed in this manual to
3. Software Release Notes June 1995 1984 2818 01x7 Software Release Notes May 1995 1984 2818 01x6 Software Release Notes January 1995 1984 2818 01x5 Software Release Notes August 1994 1984 2818 01x4 Software Release Notes November 1993 1984 2818 01x3 Software Release Notes October 1993 1984 2818 01x2 Software Release Notes for Version 17 RS3 Software Release Notes December 1992 1984 281 7 01x3 About This Manual RN vii References to Other Manuals References to other RS3 user manuals list the manual chapter and sometimes the section as shown below Sample Entries For see CC 3 For see CC 1 1 Manual Title Chapter Manual Title Chapter Section Abbreviations of Manual Titles AL Alarm Messages BA ABC Batch BQ Batch Quick Reference Guide CB ControlBlock Configuration CC Console Configuration CQ Configuration Quick Reference Guide DT Disk and Tape Functions IF Intelligent Fuzzy Logic Control Manual IO 1 O Block Configuration IT Intelligent Tuner Manual OP Operator s Guide OV System Overview and Glossary PW PeerWay Interfaces RB Rosemount Basic Language RI RNI Release Notes and Installation Guide RP RNI Programmer s Reference Manual SP Site Preparation and Installation SQ Service Quick Reference Guide SV Service RS3 Software Release Notes About This Manual RN viii Referen
4. O cold spare sometimes it does not ds 262 take over and start communicating with the controller Documen SCI hangs periodically every 2 to 3 days tation 802070 RS3 Software Release Notes System Improvements
5. SIB or VIB I O block might cause the D4 800672 console to crash when a report is generated RS3 Software Release Notes System Improvements RN 3 4 Table 3 1 RS3 Corrected Software Discrepancies in P1 L8 emm Console The console may crash if you press the arrow key on the numeric key pad and 801417 move the trackball at the same time Console Problem with graphic in V17 AND V18 R2 1 French console Duplicating portion of 801469 graphic to another location reboots the console Controller If an AOB AIB SIB or HOB is configured with no IO hardware on a point greater 801411 than 8 a bad block alarm is generated making the block useless Controller An upload of the information in a smart output device cannot be completed 801849 Controller CB documentation omission When controllers switch the data valid flag changes 801360 to O for one scan cycle of the controller processor Controller The HOB device status displays the the valve serial number instead of the final 801381 assembly number Some users would prefer to see the assembly number Controller RS3 does not allow the fieldvue secondary master to communicate with the RS3 801382 Controller When disabled and enabled a controller might become stuck in standby mode 4 800542 when it comes back up Controller There is no error message when an SIB or VIB block is loaded to another card in 4 800679 the cage and the SIB or HOB tag field has an incorrec
6. Smart field devices has been Device added Support MicroMotion 9701 flow transmitter Rosemount 3095FT flow transmitter Rosemount 644 temperature transmitter 10 8 Rosemount 3144 temperature transmitter Rosemount 3244 temperature transmitter Rosemount 3095 MV mutivariable transmitter Rosemount Analytical WC3000 oxygen analyzer System A new console is available to work with the NT based RS3 Manager Operator Station This is not the same as the disk only console CC 1 Station Write Filter See PLC block enhancement in this table RS3 Software Release Notes Version P1 Enhancements to RS3 RN 1 4 Summary of Recent Hardware Releases Table 1 2 lists recent hardware which operates in the P1 environment This is not a complete list but is provided as a guide to make you aware of new hardware Table 1 2 Summary of New Hardware through Version P1 Part Number Model 6600SM 10P 5093 0001 10P 5096 0001 Description System Manager Station SMS Disk only Console Single Board RNI SBR Discrete Analog Fiber Optic PeerWay Extender PX Tap A Fiber Optic PeerWay Extender PX Tap B For More Information SV 03 SP 03 CC 1 Hardware Installation Instruction 1984 3363 0011 1984 3363 0003 1984 3363 0004 Hardware Installation Instruction 1984 3363 0009 10P 5320 0001 PLC RBL FlexTerm Hardware Installation Instruction 1984 3363 0010 10P 5352 0006 10P 5355 0006 Multipoint Di
7. e Console P1 03 e Coordinator Processor CP P1 03 e Controller Processor P1 03 e Supervisory Computer Interface P1 02 Table 1 1 describes new features of Version P1 NOTE In Table 1 1 the field labeled For More Information tells you where to find additional detail either in these release notes or in the reference manuals A key to the manual abbreviations that are used in the table appears in the front of this document RS3 Software Release Notes Version P1 Enhancements to RS3 RN 1 2 New Features of Version P1 Software Feature The following table lists new features and enhancements to P1 software Table 1 1 Summary of New Software Features in Version P1 Description For More Information Alarm Banner The format for standard and EXCH alarm list description has AL 1 Enhancement been modified to be more informative OP 6 AMS Several code level changes were made to allow the RS3 to pass Pass through through AMS Asset Management Solutions messages from the EN support field to a computer running PERFORMANCE software The RS3 does not process this information Crash Dump The crash dump format which applies to crashes occurring in the Format console and in the CP Controller is being expanded to include more system stack more user stack and some registers Disk only A modified version of the Engineering Console without a Console supporting tape or floppy drive This
8. supported by these software versions RS3 Software Release Notes Version P1 Enhancements to RS3 RN 2 1 Section 2 Version P1 Software and Hardware Requirements This section provides Version P1 software and hardware requirements and information on temporary coexistence of RS3 software versions to facilitate plant upgrades Changes in RS3 Hardware Requirements MiniConsoles 68000 and 68020 consoles and multiple CRT MTCCs are not supported in Version P1 software SRUs are not supported No floppy drives are supported in P1 software P1 controller and CP images only run in MPCII s and CPIV s P1 nodes can coexist with certain V18 nodes and you can configure those nodes from a P1 console Contact your Fisher Rosemount service representative for the available upgrade options P1 Requirements The following tables list hardware and software requirements for Version P1 If you are a current user who is upgrading to this version and release you should make sure that your system meets these requirements If your system does not contact your Fisher Rosemount sales or service representative e Table 2 1 CPIV and CPIV requirements using P1 software images e Table 2 2 Image requirements for CPIV with V18 CPIV functionality no batch e Table 2 3 CPII requirements e Table 2 4 I O requirements e Table 2 5 Console processors 68040 e Table 2 6 Console accessories trackball etc e Table 2 7 Miscel
9. 004 1984 3222 1004 1984 3222 2004 1984 2889 0004 1984 2889 1004 1984 1978 000x Keyboard Interface Card KBI Standard Keyswitch and Dual Keyswitch Remote Keyswitch Password Security Standard Keyswitch Remote Keyswitch Standard Keyswitch without video isolation 1984 3289 000x 1984 3389 000x Viper 2060S Magnetic Tape Drive Viper 2150S Magnetic Tape Drive 1984 3318 000x Fujitsu DL3800 Printer 1984 3270 0001 ControlFile Data Bus Terminator board 1984 4080 0001 Multipoint Discrete I O FIM 1984 4167 000x 1984 4282 000x 1984 4344 000x High Density Isolated Discrete Termination Panel Multi FIM Discrete Termination Panel Standard Remote Termination Panel 1984 3278 000x Fiber Optic I O Converter 1984 4308 000x Loop Power Module 1984 4414 000x 1984 4418 000x RS3 Software Release Notes Multipoint Analog Input FIM Multipoint Analog Output FIM continued on next page Version P1 Enhancements to RS3 RN 1 6 Table 1 2 Summary of New Hardware through Version P1 Part Number Description For More Information 1984 2530 0001 QBI Hardware Kit MicroVax Il Series 1984 2627 0001 QBI Hardware Kit MicroVax 3xxx Series and VAX 4xxx series 1984 3261 0002 QBUS Board 1 CPU Card RS3 Network Interface RNI 1984 4323 0001984 RNI Power Regulator 4270 0001984 4457 RNI PeerWay Interface 0002 RNI CPU board 1984 4386 000x RNI cabinet assembly R
10. 84 2347 0021 1984 2347 0011 1984 1598 0001 1984 1483 000x 1984 1224 000x Boot Type ROM Control Type File Name MPCAxx SMARTxx You can use an MPCII with a CPII if you jumper the MPCII to be an MPCI NOTE MPCASxx MPCAPxx MPCATxx MPTUNxx PLCMxx e CPIl is supported by CPMAX image only The CPII standard image is not part of the P1 release e CPI is not supported in P1 software CPI s should be upgraded to CPIV s RS3 Software Release Notes Software and Hardware Requirements RN 2 6 I O Requirements Table 2 4 1 O Requirements Part Number Card Name Added Functionality 1984 1304 000x Contact I O 1984 1460 000x 1 Contact I O 1984 2518 0001 Analog FIC 125 s scan time 1984 2518 0002 Analog FIC 1984 2519 0002 Analog FIC SMART RIOB 268 or 275 Handheld 125 s scan time HART Output Block HART Pass through 1984 2546 000x Pulse I O FIC 1984 2731 000x Temperature FIC 1984 4080 000x MDIO I O FIM 10P 5352 0006 L 10P 5355 0006 H DIO2 FIM CE compliant 1984 441 4 000x MAIO Input FIM 1984 4418 000x MAIO Output FIM 10P 5319 0004 RS3 Software Release Notes Multipoint Analog Input High Density 32 points 1 f you are using a serial Contact FlexTerm 1984 2576 000x you m
11. S3 Software Release Notes Version P1 Enhancements to RS3 RN 1 7 Hard Drive Compatibility Console Software Revi sion English Table 1 3 lists the hard drives that are compatible with the latest software revisions NOTE 68000 and 68020 consoles are not supported in P1 Only the 68040 console is supported Table 1 3 Console Hard Drive Compatibility Matrix 040 with V10 08 Boot ROMS or higher LPS105S LPS170S 2708 040 with V10 04 V10 07 Boot ROMS N A All 68020 N A All 68000 N A V18 03 and up LPS105S LPS170S 2708 LPS105S LPS170S 2708 LPS105S LPS170S 2708 N A V17 06 N A N A LPS105S N A V17 01 N A N A LPS105S N A V16 N A N A LPS105S N A V15 20 N A N A LPS 105S LPS170S 2708 LPS 105S LPS170S 2708 V15 14 N A N A LPS105S LPS105S V15 12 amp lower N A N A 68000 consoles not supported by these software versions 68020 consoles not supported by these software versions 68040 consoles not supported by these software versions LPS105S LPS105S Floppy Drive Compatibility P1 Software does not support floppy drives RS3 Software Release Notes Version P1 Enhancements to RS3 RN 1 8 Tape Drive Compatibility Console Software Revision English Table 1 4 lists the tape drives that are compatible with the lat
12. and CPIV Requirements Using P1 Software Images Memory Controllers Images Size Type 2MB NV RAM 1MB NV RAM 1MB Bubble Part Number 1984 2347 0021 1984 2347 0011 1984 1598 0001 Boot Type Rom Control Type MPC2 PLC MUX File Name MPC2 _xx RBLC2 RBLC2_xx 2MB NV Memory RS3 Software Release Notes 1984 2347 0021 ABC Batch CP HBA P1 Software and Hardware Requirements RN 2 4 Memory Controllers Table 2 2 Image Requirements for CPIV with V18 CPIV Functionality No Batch Images Size Type 2MB NV RAM 1MB NV RAM 1MB Bubble Part Number 1984 2347 0021 1984 2347 0011 1984 1598 0001 Boot Type Rom Control Type File Name MPC2 _xx RBLC2_xx 2MB NV RAM 1MB NV RAM 1MB Bubble 1984 2347 0021 1984 2347 0011 1984 1598 0001 STDCxx If you upgrade to a CPIV or CPIV from a CPII with CC MLC SSC or MUX you must load the STDCxx image to the CPIV CPIV as an additional image NOTE MPCl s are not supported in a CPIV ControlFile with P1 software MPCI s must be upgraded to MPCII s RS3 Software Release Notes Software and Hardware Requirements Table 2 3 CPII Requirements Memory Memory Controllers RN 2 5 Images Size Type 2MB NV RAM 1MB NV RAM 1MB Bubble 5MB Bubble SMB Bubble Part Number 19
13. ce Documents Prerequisite Documents You should be familiar with the information in the following documents before using this manual System Overview Manual and Glossary Software Release Notes Performance Series 1 Software Loading and Upgrade Procedure Including Batch Related Documents 1984 2640 21x0 1984 2818 0110 1984 2818 0210 You may find the following documents helpful when using this manual ABC Batch Quick Reference Guide ABC Batch Software Manual Alarm Messages Manual Configuration Quick Reference Guide Console Configuration Manual ControlBlock Configuration Manual I O Block Configuration Manual Operator s Guide PeerWay Interfaces Manual RNI Programmer s Reference Manual RNI Release Notes and Installation Guide Rosemount Basic Language Manual Service Manual Volume 1 Service Manual Volume 2 Service Quick Reference Guide Site Preparation and Installation Manual Software Discrepancies for Performance Series 1 User Manual Master Index RS3 Software Release Notes 1984 2818 1103 1984 2654 21x0 1984 2657 19x1 1984 2812 0808 1984 2643 21x0 1984 2646 21x0 1984 2645 21x0 1984 2647 19x1 1984 2650 21x0 1984 3356 02x1 1984 3357 02x1 1984 2653 21x0 1984 2648 21x0 1984 2648 31x0 1984 2816 0904 1984 2642 21x0 1984 2818 0311 1984 2641 21x0 About This Manual RN 1 1 Section 1 Version P1 Enhancements to RS3 The software numbers of the subsystems for Version P1 are as follows
14. est software revisions NOTE 68000 and 68020 consoles are not supported in P1 Only the 68040 console is supported 040 with V10 08 Boot ROMs or higher Viper2150ST 2060S Scorpion Table 1 4 Tape Drive Compatibility Matrix 040 with V10 04 V10 07 Boot ROMs N A 020 with V9 18 Boot ROMs or higher N A 020 with V9 12 amp lower Boot ROMs V18 03 amp up Viper2150St 2060S Scorpion Viper2150St 2060S Scorpion Viper2150St 20608 Scorpion Scorpion Scorpion Scorpion N A V17 06 N A N A Viper2060S or Scorpion Scorpion Scorpion Scorpion N A V17 01 N A N A Viper2060S or Scorpion Scorpion Scorpion Scorpion N A V16 N A N A Scorpion Scorpion Scorpion Scorpion N A V15 20 N A N A Viper2150St 2060S Scorpion Scorpion Scorpion Scorpion Scorpion V15 14 KK N A KKK N A Viper2060S or Scorpion Scorpion Scorpion Scorpion Scorpion V15 12 amp lower N A N A Scorpion Scorpion Scorpion Scorpion t The Viper21508 can read a tape made on a Scorpion or Viper20608 but not vice versa These tape drives are only supported with a SCSI Board 1984 1140 0001 or 0003 Scorpion 68000 is not supported by these software versions 68020 is not supported by these software versions k q 68040 is not
15. is not the same as the DT System Manager Station SMS HART The Stop HART Comm command must be executed anytime a 10 8 Command third party HART valve product is being used f Modbus The new Modbus broadcast message will allow PLCB s to be configured with PLC 0 to designate a broadcast message This will only apply to write messages and for this reason the user will not be allowed to configure the read option in this case Whenever PLC 0 has been configured on a PLCB a text field Broadcast will appear to inform the configurer what he has done Broadcast messages of this kind will only apply to the protocols Modbus ASCII Modbus RTU and Modbus RTU 2 PID Velocity The velocity option vel in the Options Opt field of a PID block Algorithm is now valid for PI action CB 2 Option PLC Block Add new Read and Write Filter options that allows reading writing 10 9 Enhancement a PLC block at a configurable rather than a default system time i Read Filter See PLC Block Enhancement in this table Russian English and Cyrillic text can now be mixed in plant configurations Console Callup buttons can now be programmed in either Cyrillic or CC 1 Enhancement Roman text RS3 Software Release Notes continued on next page Version P1 Enhancements to RS3 Feature Table 1 1 Summary of New Software Features in Version P1 Description RN 1 3 For More Information Smart Field RS3 support for the following
16. laneous system components RS3 Software Release Notes Software and Hardware Requirements RN 2 2 PeerWay Node Type Coexistence Combinations If one ControlFile is upgraded to a new software version all other nodes on the PeerWay must be upgraded to the same level A mixture of ControlFile software functionality can coexist on a P1 PeerWay These are the nodes types and software that can coexist in a P1 environment 1 A ControlFile with CPIV P1 and MPCII P1 with and without Batch 2 A ControlFile with CPIV V18 MPCII V18 and MLC V9 po Batch 3 A ControlFile with CPMax V18 MPCI V18 and MLC V9 no Batch 4 Console P1 5 SCI P1 6 HIA V11 A PeerWay is considered to be a P1 PeerWay if it has a node described by 1 or 4 above The valid V18 version that can coexist is the released version of V18 that is included on the released P1 tapes The software numbers for the coexisting images are as follows e Coordinator Processor CPMax V18 V18 09 e Coordinator Processor CPIV V18 V18 11 e Controller Processor MPCII V18 V18 07 e Controller Processor MPCI V18 V18 07 RS3 Software Release Notes Software and Hardware Requirements RN 2 3 Determining Upgrade Requirements After you obtain information about your ControlFile use Table 2 1 Table 2 2 and Table 2 3 to determine if your current installation supports the new software CP Requirements Table 2 1 CPIV
17. make it more useful 1984 2818 0110 Usually Errors and Problems Please note errors or problems in this manual including chapter and page number if applicable or send a marked up copy of the affected page s May we contact you about your comments Name Company Phone Date Fisher Rosemount FAX 612 895 2044 Thank you Name Company Address Fisher Rosemount Systems Inc RS3 User Documentation Mail Station G30 12000 Portland Avenue South Burnsville MN 55337 U S A Seal with tape RN v FISHER ROSEMOUNT RS3 Software Release Notes About This Manual This document provides information about Performance Series Release 1 P1 software Section 1 Lists Version P1 enhancements to RS3 Section 2 Lists software and hardware requirements for Version P1 Section 3 Lists system improvements including corrected software discrepancies Changes for This Release The major enhancement changes for this release are covered in Section 1 The major discrepancy fixes are covered in Section 3 RS3 Software Release Notes About This Manual RN vi Revision Level for This Manual For This Refer to This Document Software Version Software Release Notes Date May 1996 Part Number 1984 2818 0110 Software Release Notes April 1996 1984 2818 01x9 Software Release Notes October 1995 1984 2818 01x8
18. screte I O FIM low side switch Multipoint Discrete I O FIM high side switch Hardware Installation Instruction 1984 3363 0013 1984 3363 0014 10P 5270 0001 Direct Connect Termination Panel Hardware Installation Instruction 1984 3363 0013 1984 4121 0001 1984 4124 0001 Multipoint Discrete I O Opto Termination Panel A Multipoint Discrete I O Opto Termination Panel B Hardware Installation Instruction 1984 3363 0014 1984 4282 0001 Multi FIM Termination Panel SV 6 SP 7 1984 4167 0001 High Density Termination Panel SV 6 SP 7 10P 5066 0002 Mag Innovision 15 Inch CRT Monitor 1984 0390 000x RS3 Software Release Notes AC DC Power Supply Without Battery Backup continued on next page Version P1 Enhancements to RS3 Part Number 1984 4302 000x 1984 4329 0001 1984 4329 0002 1984 4329 0003 1984 4433 xxxx Description Remote I O Power Supply AC Distribution Block DC Distribution Block 10 circuits DC Distribution Block 1 circuit DC I O Power Cable B Bus RN 1 5 Table 1 2 Summary of New Hardware through Version P1 For More Information 1984 3211 000x 1984 3214 000x Optical PeerWay Tap Box A Optical PeerWay Tap Box B 1984 3202 00xx OI Processor V 68040 1984 3286 000x 1984 3246 000x 1984 2633 000x Sony 14 Inch CRT Monitor CPD 1430 Sony 14 Inch CRT Monitor CPD 1304S Sony 14 Inch CRT Monitor C 1404S 1984 3222 0
19. sequent icon Batch If the ABC Log Folder is full and an operator modifies a Working Recipe the 801906 console may hang or crash and the recipe becomes inaccessible Redundant controller processors do not always boot up on the first try 152818 O U Comm SCI cannot read field codes higher than 1500 800356 Comm On the SCI saving the configuration and sending a message pair in quick 800857 succession might disable data transmission Console Items defined in event list configuration are not readable when printed from a 800804 68040 console They print correctly from a 68020 console Console If a block descriptor uses all 24 characters the BLKDES graphic object does not 800976 display the descriptor Console When configuring a console with a blank disk the default size of the Console 152821 Program Folder is too small to boot the console software D4 D4 Comm Error in V18 PeerWay Interface Manual for field codes 5 amp 6 page 1 4 7 SCI D1 800256 cannot write to the block mode and output of I O blocks SCI can only write to the block mode and output of ControlBlocks D3 RS3 Software Release Notes System Improvements RN 3 3 Table 3 1 RS3 Corrected Software Discrepancies in P1 Le mem 0 rem Console On the Report Config Directory screen the autoprint status is displayed as a 801226 garbage character instead of a Y or N Russian consoles only The SIB block alarms display garbage characters 801242
20. t address Controller If you change an HOB from digital to analog you must execute the Update xmtr 4 801113 variables command to implement the change Controller System flags for block inputs A through O are interpreted as user flags D 801387 Controller A secondary master device may not be able to calibrate a smart output field D4 801388 device if the RS3 changes the HOB mode during an upload Controller RS3 V18R2 3 cannot support some PLCs because RS3 asks for more coils than 4 801426 are configured in the PLC Controller In a ControlBlock the ssm seconds since midnight time function can alter the D4 800573 values of subsequent time functions RS3 Software Release Notes System Improvements RN 3 5 Table 3 1 RS3 Corrected Software Discrepancies in P1 o emm nme Controller On HOB when the HOB is switching back from digital to analog the valve display 801471 does not automatically show the right control mode Documen If the new ASCII file is smaller than the original file the ASCII conversion is tation successful but an alarm says it was unsuccessful 800660 Documen Process Unit Icons multiple in main illegal swapping unit names tation 801990 Transmitter 9739 hardware alarms can overwhelm the maintenance log a Downloading an FIM program on a controller Serial communication line fails if the us SIB block is configured and in alarm mode When a 4080 FIM is installed as a discrete I
21. tight loop causing PeerWay problems Batch When two batch operations are run in parallel Left CP Data Integrity errors are D2 801183 generated up to a rate of 10 alarms sec Batch A CP goes down before a Unit Recipe start is backed up to bubble memory D2 801351 When the CP recovers there is no way to restart the Unit Recipe The batch input window on a graphic does not update and display new messages pe 801404 Batch Recipe misses icons in Parallel Recipe execution 802029 Batch Occasionally when calling up a Batch Working Recipe screen only the top menu 802190 is displayed and the rest of the screen is blank RS3 Software Release Notes System Improvements D4 D2 D2 RN 3 2 Table 3 1 RS3 Corrected Software Discrepancies in P1 ern Batch When you restart a Batch Working Recipe suspended in Static mode the Recipe D3 800699 View menu receives a Config warning Batch The recipe info screens do not display all Batch configuration fields D3 801066 Batch Working recipe icon is wrong color after executing D4 800498 Batch Duplicate child task started after power failure 800671 Batch The Master Recipe validation may hang with more than 10 warnings or errors Ed 801106 Batch The Working Recipe screen displays two STATIC marks if the recipe is put into D4 801349 static while an icon is in the SCHEDULED state Batch A start unit recipe start_UR icon does not execute if it does not have a link toa 801365 sub
22. ust use this card 1984 1460 000x Software and Hardware Requirements Console Requirements RN 2 7 Processor Part Number 10P 5527 0011 SMS Keyboard Revisions Device Revision Table 2 5 Console Ol Processor Storage RS3 T1 45S qic 45 Table 2 6 Console Accessories Secure Keyboard SCSI Adapter RS3 T3 150S qic 150 SCSI Board 2 1984 3301 0001 RS3 T2 60S qic 60 SCSI Host Adapter 1984 1140 0001 Part Number 10P 5084 2004 1984 3222 2004 Enhanced operator engineer keyboard 10P 5084 0004 1984 3222 0004 Configuror Keyboard 1984 3222 1004 TB Trackball DISPPNL Operator Keyboard OPTPNL1 OPTPNL2 OPTPNL3 CE compliant RS3 Software Release Notes Options Keyboard 1084 1632 000x Software and Hardware Requirements RN 2 8 Identify Requirements for other System Components Table 2 7 lists requirements for other RS3 system components Table 2 7 Miscellaneous System Components System Component RNI Boot ROM Processor Software HIA 60000 SCI 60000 1 MB Diogenes 60000 1 MB MicroVAX with Host Mode RS3 Software Release Notes RMT host software 4 0 Software and Hardware Requirements RN 2 9 Memory Allocations and Plant Program Space If you have CPIV ControlFile And you have 1 Meg 2 Meg NV Memory NV Memor non batch
23. y Then you have this much memory space to load Plant Programs Images Figure 2 1 Memory Allocations and Plant Program Space NOTE Be sure to calculate available space for plant programs and images to be used before upgrading software Check plant program image sizes from file size number in the Plant Program Folder RS3 Software Release Notes Software and Hardware Requirements RN 3 1 Section 3 System Improvements This section describes improvements to the RS3 system including corrected discrepancies Corrected Discrepancies Table 3 1 lists corrected discrepancies in Version P1 The table itself is organized alphabetically by subsystem then by rating with higher ratings appearing first The ID column specifies the RS3 subsystem Batch Controller Console Comm Documentation or I O followed by a number used to track this change The Rating column contains a two character code The letter stands for the type of change made to the software D stands for discrepancy and the number is a measure of its importance with 1 being the most important NOTE While many of the descriptions seem to indicate a problem by the way the sentence is phrased in fact they are a description of a problem that has been verified and fixed Table 3 1 RS3 Corrected Software Discrepancies in P1 S NN 73 Batch All running recipes while not downloading scripts or handling exceptions do disk 801337 reads in a
Download Pdf Manuals
Related Search
Related Contents
INSTRUCTION BOOK Stage Blinder 4 DMX Black KOSP 6610 Mode d`emploi Microdata User Guide RESIDENTIAL TELEPHONE SERVICE Kam LED Partybar V2 Origin Storage 1TB TLC SATA Unidad de limpieza de mangueras de polvo OptiAir CA07 ASUS T100TAF User's Manual Bain-Marie - Party Rent Bomers & Hoffman Copyright © All rights reserved.
Failed to retrieve file