Contents

1. M button 5 g 2 The stored results with date are displayed in order from the most ae i i H pA 8 15 pm EDS recent to the oldest via pressing and releasing the M button The a meter will turn off automatically in 3 seconds when the symbol is displayed on the screen If you decide to stop checking the results stop pressing the M button The meter will turn off automatically in 30 seconds or via pressing S button No test can be performed when you are checking the stored results If you wish to perform a new test please turn off the meter first and restart the steps described in the section Blood Glucose Cholesterol Uric Acid Testing Deleting the Stored Memory of Blood Glucose Cholesterol Uric Acid Test Results When the newest blood Glucose Cholesterol Uric Acid test result is displayed press S button for 3 seconds The newest blood Glucose Cholesterol Uric Acid test result is deleted as soon as you hear the beep sound from the meter The stored results can be deleted in order from the most recent to the oldest via press S button for 3 seconds If you decide to stop deleting the results stop pressing the S button The meter can automatically turn off in 30 seconds or via pressing S button 35 wo A wo N Taking Care of Your Meter Maintaining the Meter eDo not drop hit or smash your meter eKeep your meter between 10 C
2. is displayed on the screen anaana 5 If you decide to stop checking the results stop pressing the M button The meter will turn off automatically in 30 seconds or via pressing S button 6 No test can be performed when you are checking the stored results If you wish to perform a new test please turn off the meter first and restart the steps described in the section Blood Glucose Cholesterol Uric Acid Testing Review the Stored Cholesterol Test Results 1 Please enter the cholesterol test mode first Insert the cholesterol i a code key blue color and press M button 194 2 The stored results with date are displayed in order from the most BIS m EES recent to the oldest via pressing and releasing the M button The meter will turn off automatically in 3 seconds when the symbol is displayed on the screen anon 3 If you decide to stop checking the results stop pressing the M button The meter will turn off automatically in 30 seconds or via pressing S button 4 No test can be performed when you are checking the stored results If you wish to perform a new test please turn off the meter first and restart the steps described in the section Blood Glucose Cholesterol Uric Acid Testing 34 Review the Stored Uric Acid Test Results 1 Please enter the uric acid test mode first Insert the uric acid UA q code key orange color and press
3. Control Batch code In vitro diagnostic device Catalogue number 43 R Sterilized using irradiation Guidance and manufacturer s declaration electromagnetic emissions This device is intended for use in the electromagnetic environment specified below The customer or the user of this device should assure that its used in such an environment RF emissionsCISPR 11 Group 1 This device uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment RF Eons A Vis vc sual Tor us iva elabiahrenis ang domes eelablshmaris and those desy nec othe pubic Iowi vollege power uP two Na Supple bulge used fer demest Harmonie emissions EC 6100032 Not applicati Connected the piba a veline power suply network a supple bulngs use fet domestic Vonage PuctuatonsAicker emissors E C 700088 To applicatie Guidance and manufacturer s declaration electromagnetic immunity This device is intended for use in the electromagnetic environment specified below The customer or the user of this device should assure that itis used in such an environment Immunity test IEC 60801 test level Compliance level Electromagnetic environment guidance Electrostatic discharge ESD 46 KV contact 6 KV contact Floors should be wood concrete or ceramic tile If floors are covered with 2 8 KV air 28 KV air synthetic material the relative
4. Table of Contents What is GlucoAlpha 3 in 1 System TOf a a a a 3 Important NOMAN euesan vacdeceadtensesdseataaeddieaceiiads detested nokta teva d Items in the Package 0 0 0 000 Items Need to be Purchased Separately Getting to Know GlucoAlpha 3 in 1 Blood Glucose Cholesterol Uric Acid Multi Function Monitoring SyStemsiisiio sitesi Soli ni oti ataaeete Maa 8 EEL O EET ATTAT EE T T 9 Setting Up Your GlucoAlpha 3 in 1 Multi Function Monitoring System a10 Setting Dats and TIMSS anini a ee vO Checking the Unit of Measurement 2 2c 2 ecseseeeeeeeeeeeeeeeeseeeeeceeeseeseseensensensaeaeeaenen 10 The Batteries InstallatiOnscisicccccascsnccnecnannecintuacia ter uarnacunenadtenaiyaecaivarraivaassiaateciyncestzanssiee 11 Using Check Strip to Check the Meter eee 22 Control Check with Glucose Cholesterol Uric Acid Control Solutions 0 5 When to Run a Control Check with Glucose Cholesterol Uric Acid Control Solution Items You Neede jccscsesestev a ntetenys eel eae ees aren Senna E L Steps for Running a Glucose Control Check Steps for Running a Cholesterol Control Check Steps for Running a Uric Acid Control Check How to Read the Label on the Test Strip Vial eccceceeseseeeeeeereeeeeeeeeeeeeeeeeeeseeereeeeeaeenes 19 Analyzing Your Control RESUS a uusissa eden A EE SA 20 Blood Glucose Cholesterol Uric Acid TeSting csscceeeeeeeeteeeeeereeeeeeese
5. immediately Your blood Uric Acid level is Re check your blood uric acid level If lower than 3 mg dL LO is displayed again call your doctor 179 pmol L immediately 39 SYMBOL WHAT IT MEANS ACTION Operating procedure is incorrect Repeat the test with a new test The test strip has been used or the strip If the symbol is displayed meter is not performing correctly jagain contact Customer Service 1 Check the code key Be sure the code key is inserted into the code key slot completely 2 Insert the code key 1 Using a wrong code key or the code key is inserted improperly 2 New meter hasn t been code The code key is damaged Contact Customer Service 505 105 Specifications GlucoAlpha 3 in 1 Multi Function Monitoring System Measuring Range 20 600 mg dL 100 400 mg dL 3 20 mg dL g hang 1 1 33 3 mmol L 2 6 10 4 mmo L 179 1190 mol L Calibration Plasma equivalent 150 seconds Memory Capacity 200 test results 50 test results 50 test results Eran Cholesterol Operating Condition Temperature 14 40 C 57 2 104 F Humidity lt 85 Relative Humidity Meter Storage Condition Transportation Condition Temperature 10 60 C 14 140 F Humidity lt 95 Relative Humidity Sample Volume 2 0 8 ul 2 0 8 ul Sample Type HxWxD mm 90 x 66 x 22 Electrode based Biosensor The Meter has been safety and EMC test
6. Strips Uric Acid Test Strips Control Solutions GlucoAlpha Glucose Control Solution 3 ml GlucoAlpha Cholesterol Control Solution 1 ml GlucoAlpha Uric Acid Control Solution 3 ml Getting to Know GlucoAlpha 3 in 1 Blood Glucose Cholesterol Uric Acid Multi Function Monitoring System Code Key Slot Test Strip Slot bah dic Unit Changing Switch To Switch between mg dL and mmol L umol L Battery Cover Screen Display Messages and Test Result Memory Button Recall Stored Data Setting Date and Time Button Battery Compartment est Strips GlucoAlpha Blood Glucose Test Strips farget area You must fill the whole area with blood Sample target area Strip handle Yon may touch here Contact bars Insert this end to test strip slot on the meter GlucoAlpha Cholesterol Test Strips Sample target area argel area You must fil the whole rea with blood Strip handle fon may touch here Sample target area You may apply your blood on either side of the sample target area Contact bars Insert this end to test strip slot on the meter GlucoAlpha Uric Acid Test Strips ample target area Strip handle Yon may touch here argel area You must fil the whole ea with blood Contact bars Insert this end to lest strip slot on the meter Setting Up Your GlucoAlpha 3 in 1 M
7. Uric Acid Control eYou think there is something wrong with the glucose cholesterol or uric acid measurement you got and you want to check whether meter and test strips are working correctly or not Items You Need eGlucoAlpha 3 in 1 Meter eGlucoAlpha Blood Glucose Control Solution option eGlucoAlpha Cholesterol Control Solution option eGlucoAlpha Uric Acid Control Solution option eGlucoAlpha Blood Glucose Test Strips eGlucoAlpha Cholesterol Test Strips eGlucoAlpha Uric Acid Test Strips eGlucose Cholesterol Uric Acid code keys in the test strips box 13 Steps for Running a Glucose Control Check 1 Insert the glucose code key into the code key slot on the back of the meter 2 Take one strip from the vial Close the vial quickly 3 Insert the test strip into the test strip slot on the meter The meter will first display code number then the blood symbol 8 14 4 Hold the glucose control solution bottle upside down slowly squeeze the bottle to form a small drop discard the first drop of the solution let the second drop touch the edge of the sample targeting area on the test strip The control solution will be drawn N into the targeting zone automatically 5 You will hear a beep sound Close the cap of the control solution immediately The meter starts to count down 6 seconds then 5 shows your result on the screen gi m t05 6 Check if the display
8. and 60 C 14 F and 140 F and below 95 of relative humidity Do not store meter in area such as the kitchen bathroom laundry room or car eKeep the meter away from water eDo not use glass household cleaning solutions to clean the meter Simply use an alcohol pad to wipe the surface of the meter but do not wipe the test strip slot or code key slot eDo not disassemble the meter elf you have any questions please contact Customer Service or your healthcare provider he Battery Replacement When the symbol E is displayed on the screen please replace batteries immediately 1 Slide battery cover off from the back of the meter 2 Remove old batteries and insert 2 new AAA size batteries 1 5V into the battery compartment 3 Slide battery cover back and turn on your meter 36 Cleaning the Meter You can clean your meter with 70 isopropyl alcohol swab Troubleshooting Guide SYMBOL WHAT IT MEANS ACTION The battery power is low Replace new batteries LO flashes 5 times before the meter turning off automatically The batteries are dead Replace new batteries 37 SYMBOL WHAT IT MEANS ACTION Repeat the test in a warm place about 14 C 40 C 57 2 F 104 F You may need to wait as long as 20 minutes for the meter to warm up before testing again The environmental temperature is too low to perform a test Repeat the test in a cool place ab
9. humidity should be at least 30 Power frequency 50 60 Hz Power frequency magnetic fields should be at levels characteristic of a typical magnetic field 3m location in a typical commercial or hospital environment IEC 61000 4 8 NOTE UT is the a c mains voltage prior to application of the test level 44 Guidance and manufacturer s declaration electromagnetic immunity This device is intended for use in the electromagnetic environment specified below The customer or the user of this device should assure that itis used in such an environment Immunity test IEC 60601 test level Compliance level Electromagnetic environment guidance Portable and mobile RF communications equipment should be used no closer to any part of this device including cables than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter Recommended separation distance Radiated RF avin d 12 p d 1 2 9 80 MHz to 800 MHz d 1 2 p 800MHzto 2 5 GHz IEC 61000 4 3 80 MHz to 2 5 GHz where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer and d is the recommended separation distance in metres m Field strengths from fixed RF transmitters as determined by an electromagnetic site survey should be less than the compliance level in each frequency range p Interference may occur in the vicinity of equipment marked with the following symb
10. the number on the code key matches the code number on the vial of test strips you use L 2 Take one strip from the vial Close the vial quickly 3 Insert the test strip into the test strip slot on the meter The meter will first display code number then the blood symbol 6 4 When the screen shows blood symbol 6 clean your finger with alcohol swab Let it dry completely Gu Tod ou 5 Place the puncturer on your finger nn i i bau 81S m FOS Press the trigger on the puncturer Lift up the puncturer Get a drop of blood Put the drop of blood on the edge of the test strip target area The blood will be absorbed and cause the target area to turn red The testing reaction starts when the meter beeps The meter starts to count down 6 seconds then shows your result on the screen The meter stores your result in its memory automatically Glu Glu 6 5b B15 m OS BIS m HES OOND 10 Record the glucose value in your log book 11 Pull the test strip out of the meter The meter will turn off by itself Unscrew the adjustable tip of the puncturer 25 12 Put the protective cover of the lancet back on the lancet Grip the puncturer holder firmly and pull the lancet out 13 Discard the used lancet in an appropriate container with a lid a 14 Screw the adjustable tip back on the puncturer Understanding Your Blood Gluco
11. the puncturer Understanding Your Blood Uric Acid Test Results The expected blood uric acid value is as following Male 3 7 2 mg dL 179 428 umol L Female 2 6 mg dL 119 357 mol L However the above range is just a reference and it may not apply for every person Consult your doctor for the appropriate range for you 32 Using the Meter Memory GlucoAlpha 3 in 1 Meter can automatically store glucose cholesterol and uric acid most recent test results You can review the test results in order from the newest to the oldest If the memory is full the oldest result is deleted as the newest result is added The memory is not affected by replacing removing the batteries Review the Stored Glucose Test Results Please enter the glucose test mode first Insert the glucose code key green color and press M button 2 Pressing and releasing the M button the Phen eal E 7 day average 14 day average and 28 day gp AS AG average will be displayed on the screen in Tee Bly ua pag pg 856 order 3 After the 28 day average the newest blood glucose test result with a E date will be displayed via pressing and releasing the M button AY 4 The stored results with date are displayed in order from the most 4i eile recent to the oldest via pressing and releasing the M button The z O meter will turn off automatically in 3 seconds when the symbol
12. diagnostic use only external use only The system is for healthcare professionals and persons with diabetes hypercholesterolemia or hyperuricemia to measure glucose cholesterol and uric acid values in fresh capillary whole blood from finger stick quantitatively Frequent monitoring of whole blood glucose cholesterol and uric acid is an adjunct to the care of persons with diabetes hypercholesterolemia and hyperuricemia Simply apply a drop of blood to the test strip the test result will be displayed on the screen after 6 seconds for glucose 150 seconds for cholesterol and 6 seconds for uric acid eThe GlucoAlpha 3 in 1 System is suitable for diabetes hypercholesterolemia and hyperuricemia management at home or professional use eThe GlucoAlpha 3 in 1 Meter can only be used with GlucoAlpha Blood Glucose Test Strips GlucoAlpha Cholesterol and GlucoAlpha Uric Acid Test Strips The use of any other test strips may give incorrect results eBefore using the products to test your blood glucose cholesterol and uric acid levels read all the instructions carefully It includes all the information you need to know in order to get the accurate blood glucose cholesterol and uric acid readings eDo not change your medical plan without doctor s approval The GlucoAlpha 3 in 1 system should not be used for the diagnosis of diabetes hypercholesterolemia and hyperuricemia or for the test of newborns Important Informatio
13. ed and approved according to the requirement of EN 61010 1 EN 61010 2 101 EN 60601 1 2 EN 61326 41 Customer Services Thank you for choosing the GlucoAlpha 3 in 1 Blood Glucose Cholesterol Uric Acid Multi Function Monitoring System IN4 Technology Corporation is honored to present this new product to you Our customer services include 1 Our customers are entitled to free repair and replacement of spare parts If you have problems with the product please contact local distributor agent for further information However the following damages resulted from improper use or accidents are excluded such as smash moisture unauthorized repair disassemble and natural catastrophes 2 IN4 Technology Corporation is not responsible for any accidents and worsening illness resulted from buyers users improper use of device without the instructions of professionals e g medical personnel Consumers may not request for compensation in this regard 3 Please read this manual thoroughly before using this monitoring system 4 If you have any questions please contact local distributor or EU representative telephone 49 6894 581020 42 Labeling and Information T Temperature limitation taal Manufacturer Caution consult accompanying documents Consult instruction for use Keep away from sunlight Used by Authorized representative in the European Community A sn Serial number CONTROL
14. ed glucose value falls within the acceptable range shown on the test strip vial Gu 7 Remove the test strip from the meter and discard it AG BiS om FS 15 Steps for Running a Cholesterol Control Check 1 Insert the cholesterol code key into the code key slot on the back of the meter 2 Take one strip from the vial Close the vial quickly 3 Insert the test strip into the test strip slot on the meter The meter will first display code number then the blood symbol CHOL Code s005 16 4 Hold the cholesterol control solution bottle upside down slowly squeeze the bottle to form a small drop discard the first drop of the solution let the second drop touch the edge of the sample targeting area on the test strip The control solution will be drawn into the targeting zone automatically 5 You will hear a beep sound Close the cap of the control solution immediately The meter starts to count down 150 seconds then shows your result on the screen 6 Check if the displayed cholesterol value falls within the acceptable range shown on the test strip vial 7 Remove the test strip from the meter and discard it 17 i ni 50 B15 m 18S I m git i5 u 818 188 Steps for Running a Uric Acid Control Check CAUTION eAlways check the uric acid code key number to make sure it matches the number labeled on the test strip vial when you run a uric ac
15. eeeeeaneseeetessneeeenate 21 items YOU N d evcniescasccscececsciecieensseice case 21 Preparing the Puncturer Lancing Device 21 Structure of Puncturer and Lancet 122 Steps for Using the Puncturer 2d Testing Your Blood Glucose Level 00 124 Understanding Your Blood Glucose Test Results 126 Testing Your Blood Cholesterol LeVel e cceceeeceereeereeeeeereeeeeeeecereeaeeeesaeeeeeeareeeteneeeaeees 27 Understanding Your Blood Cholesterol Test RESUItS ccececeeeeeeeereeeeeereeereeteteneeates 29 Testing Your Blood Uric Acid Level 00 30 Understanding Your Blood Uric Acid Test Results 02 Using the Meter Memory ccssssessteeeseereeeeereee Review the Stored Glucose Test RESUItS ccccccccccsseeesneeseeeecseeeeeseeeeeeeseeeesseeeesneessaees Review the Stored Cholesterol Test Results Review the Stored Uric Acid Test Results Deleting the Stored Memory of Blood Glucose Cholesterol Uric Acid Test Results Taking Care of Your Metelynsccciae2s i ates lane nade ae ened Maintaining the Meter 06 The Battery Replacement 36 Cleaning the Meter 230 Troubleshooting Guide 37 Specifications 40 Customer Services 42 hat is GlucoAlpha 3 in 1 system for eThe self testing GlucoAlpha 3 in 1 Blood Glucose Cholesterol Uric Acid Multi Function Monitoring System is designed for in vitro
16. id control test Otherwise you may get incorrect results eAlways write down the opening date of your uric acid control solution vial and test strip_ vial Both of them are good for only 2 months after first opening or until the expiration date whichever comes first e The result will be stored in memory and appear just like the blood Uric Acid result 1 Insert the uric acid code key into the code key SP slot on the back of the meter 2 Take one strip from the vial Close the vial quickly P A ww gog 4 3 Insert the test strip into the test strip slot on i K the meter The meter will first display code number then the blood symbol Cautions Make sure that the code number shown on the screen is the same as the code number printed on the uric cid test strip vial otherwise you may get incorrect measurement 18 4 Hold the uric acid control solution bottle upside down slowly squeeze the bottle to form a small drop discard the first drop of the solution let the second drop touch the edge of the sample target area on the test strip The control solution will be drawn into the target zone automatically 5 You will hear a beep sound Close the cap of the control solution immediately The meter starts to count down 6 seconds then shows your result on the screen 6 Check if the displayed uric acid value falls within the acceptable range BIS m 05 shown on the test strip vial T 7 Re
17. lpha Uric Acid Test Strips eGlucose code key green color in the glucose test strips box eCholesterol code key blue color in the cholesterol test strips box eUric Acid code key orange color in the Uric Acid test strips box ePuncturer eLancets eAlcohol swab not included eLog book Preparing the Puncturer Lancing Device 21 ructure of Puncturer and Lancet Lancet Remove Sliding Adjustable tip Lancet 4 y Protective cover Trigger Carrier 22 Sliding barrel Steps for Using the Puncturer 1 Unscrew and remove the puncturer s adjustable tip Insert a lancet into the carrier Twist off the protective cover Replace the adjustable tip tightly Choose a desired skin penetration depth by rotating the top portion of the adjustable tip until the setting number lines up to the arrow Settings are based on skintype Depth 1 2 for soft or thin skin Depth 3 for average skin Depth 4 5 for thick or calloused skin Hold the tip of the puncturer with one hand and pull the sliding barrel with the other hand When a click is felt the trigger rises up Release the sliding barrel it will move back to its original position 23 Testing Your Blood Glucose Level 1 When you first time use the GlucoAlpha 3 in 1 meter or open a new test strip vial insert the code key from the test strip vial Each test strip vial contains one code key Make sure
18. move the test strip from the meter and discard it 56 BiS m EOS How to Read the Label on the Test Strip Vial Label on the Test Strip Vial Product roduct name GlucoAlpha 3m1 2 Code number of this tot or tet strip Suitable for Self Testing ee etsy Typ of the Test Sip The results of the conrol solution test should fall within the specified ranges You should fil in the Example ee lt opening date here 19 Analyzing Your Control Results You will find the acceptable range of glucose cholesterol and uric acid levels for the normal and high controls on the test strip vial label If your control results fall within the acceptable range you can begin to test your blood glucose cholesterol or uric acid levels If your control results are not within the acceptable range check the following items eAre your Glucose Cholesterol Uric Acid Test Strips or control solutions expired eHave you ever forgotten to close your Glucose Cholesterol Uric Acid Test Strip vials or control solution bottles eDoes the code in the meter match the code on the test strip vial eDo you follow all the operation instruction correctly eRepeat the control test with a new test strip following the steps exactly Blood Glucose Cholesterol Uric Acid Testing Items You Need eGlucoAlpha 3 in 1 Meter eGlucoAlpha Blood Glucose Test Strips eGlucoAlpha Cholesterol Test Strips eGlucoA
19. n eBlood specimens containing Ascorbic Acid Vitamin C greater than 150 mg dL Amiloride greater than 20mg dL Acetaminophen greater than 8mg dL L Dopa greater than 20 mg dL Dopamine greater than 20 mg dL Methyl Dopa greater than 4 mg dL Galactose greater than 400 mg dL Uric Acid greater than 10 5 mg dL and Xylose greater than 50 mg dL may give inaccurate glucose results eBlood specimens containing Ascorbic Acid Vitamin C greater than 5 mg dL Acetaminophen greater than 15 mg dL L Dopa greater than 1 25 mg dL Dopamine greater than 3 mg dL Methyl Dopa greater than 5 mg dL Glibenclamide greater than 10 mg dL Creatinine greater than 20 mg dL and Billirubin greater than 20 mg dL may give inaccurate cholesterol results eBlood specimens containing Ascorbic Acid greater than 10mg dL Acetaminophen greater than 2mg dL L Dopa greater than 20 mg dL Dopamine greater than 5mg dL Methyl Dopa greater than 1 0 mg dL Glibenclamide greater than 10mg dL Cholesterol greater than 400 mg dL Creatinine greater than 30 mg dL Diclofenac greater than 75 mg dL Amiloride greater than 20 mg dL and Ketoprofen greater than 500 mg dL may give inaccurate uric acid results eLipaemic samples Cholesterol up to 500 mg dL or triglycerides up to 3000 mg dL have not been test and are not recommended for testing with the GlucoAlpha 3 in 1 Monitoring System eHematocrit percentage of red blood cells in your blood below 30 or higher than 55 was f
20. nsert the code key from the test strip vial Each test strip vial contains one code key Make sure the number on the code key matches the code number on the vial of test strips you use 2 Take one strip from the vial Close the vial quickly 3 Insert the test strip into the test strip slot on the meter The meter will first display code number then the blood symbol 4 When the screen shows blood symbol 6 igen your fi inger with alcohol swab Let it dry completely gode 5 Place the puncturer on your finger agg 30 Press the trigger on the puncturer Lift up the puncturer Get a drop of blood Put the drop of blood on the edge of the test strip target area The blood will be absorbed b and cause the target area to turn red The testing reaction starts when the meter beeps The meter starts to count down 6 seconds then shows your result on the screen The meter stores your result in its memory automatically 6 56 BIS m OS BiS m 05 OOND 10 Record the uric acid value in your log book 11 Pull the test strip out of the meter The meter will turn off by itself Ja Unscrew the adjustable tip of the puncturer 31 12 Put the protective cover of the lancet back on the lancet Grip the puncturer holder firmly and pull the lancet out 13 Discard the used lancet in an appropriate container with a lid 14 Screw the adjustable tip back on
21. ol NOTE 1 AtBO MHz and 800 MHz the higher frequency range applies NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people a Field strengths from fixed transmitters such as base stations for radio cellular cordiess telephones and land mobile radios amateur radio AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy To assess the electromagnetic environment due to fixed RF transmitters an electromagnetic site survey should be considered If the measured field strength in the location in which this device is used exceeds the applicable RF compliance level above this device should be observed to verify normal operation If abnormal performance is observed additional measures may be necessary such as reorienting or relocating this device b Over the frequency range 150 kHz to 80 MHz field strengths should be less than 3 V m 45 Recommended separation distances between portable and mobile RF communications equipment and this device This device is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled The customer or the user of this device can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment transmitters and this device as recommended below according to
22. ound to cause a higher or lower reading respectively No significant effect on the reading was found for hematocrits in the blood sample between 30 and 55 eThe monitoring system will not work properly at altitudes greater than 8 000 feet eThe system is designed to use at temperatures between 14 C and 40 C 57 2 F and 104 F and below 85 of relative humidity If you use the system outside the proposed conditions it can give false results eBe sure to store the test strips between 4 C and 30 C 40 F and 86 F and avoid direct sunlight eBe sure to follow your local regulations for proper disposal of used test strips and lancets eDo not use this meter in a dry environment especially if synthetic materials are present Synthetic clothes carpets etc may cause damaging static discharges ina dry environment eDo not use this meter near cellular or cordless telephones walkie talkies garage door openers radio transmitters or other electrical or electronical equipment that are sources of electromagnetic radiation as these may interfere with the proper operation of the meter Items in the Package OGlucoAlpha 3 in 1 Meter GlucoAlpha 3 in 1 User s Manual Puncturer lancing device Log Book Lancets Check Strip Pouch Two AAA Batteris Items Need to be Purchased Separate Test Strip comes with a code key GlucoAlpha GlucoAlpha GlucoAlpha Blood Glucose Test Strips Cholesterol Test
23. out 14 C 40 C 57 2 F 104 F You may need to wait as long as 20 minutes for the meter to cool down before testing again The environmental temperature is too high to perform a test If the test result is over 240 mg dL the blood glucose gas EBS test result with a suggestion to check your ketone levels Re check your blood glucose level Follow the instructions of your healthcare professional regarding ketone testing Example Your blood glucose level is higher than 600 mg dL 33 3 Re check your blood glucose level If mmol L The blood glucose HI is displayed again call your doctor BIS ee eg test result with a suggestion Jimmediately om FU to check your ketone levels 38 SYMBOL WHAT IT MEANS ACTION Your blood glucose level Re check your blood glucose level If is lower than 20 mg dL LO is displayed again call your doctor 1 1mmol L immediately Your blood cholesterol level _ Re check your blood cholesterol level If is higher than 400 mg dL HI is displayed again call your doctor 10 4 mmol L immediately Your blood cholesterol Re check your blood cholesterol level If level is lower than 100 mg LO is displayed again call your doctor dL 2 6 mmol L immediately Your blood uric acid level is Re check your blood uric acid level If higher than 20 mg dL HI is displayed again call your doctor 1190 pmol L
24. ry automatically NOTE How much blood should be applied Although only a small amount of blood is needed it is very important that you put enough blood on your test strip so that the entire reaction zone is covered with blood This ensures that your meter can give accurate and reliable results Example The blood volume needed in cholesterol test is at least 15ul As a je reference the round shaped blood formed on your finger should be at laut III Lin least 0 5 cm diameter Caution If you don t apply enough blood you might need to use a new test strip to do the test again 8 O OND 28 10 Record the cholesterol value in your log book 11 Pull the test strip out of the meter The meter will turn off by itself Unscrew the adjustable tip of the puncturer 12 Put the protective cover of the lancet back on the lancet Grip the puncturer holder firmly and pull the lancet out 13 Discard the used lancet in an appropriate container with a lid 14 Screw the adjustable tip back on the puncturer z Understanding Your Blood Cholesterol Test Results Normal fasting blood cholesterol is below 200 mg dL However the above range is just a reference and it may not apply for every person Consult your doctor for the appropriate range for you Testing Your Blood Uric Acid Level 1 When you first time use the GlucoAlpha 3 in 1 meter or open a new test strip vial i
25. se Test Results According to the suggestions of American Diabetes Association Normal fasting blood glucose is 70 100 mg dL 3 9 5 6 mmol L However the above range is just a reference and it may not apply for every person Consult your doctor for the appropriate range for you Testing Your Blood Cholesterol Level 1 When you first time use the GlucoAlpha 3 in 1 meter or open a new test strip vial insert the code key from the test strip vial Each test strip vial contains one code key Make sure the number on the code key matches the code number on the vial of test strips you use 2 Take one strip from the vial Close the vial quickly 3 Insert the test strip into the test strip slot on the meter The meter will first display code number then the blood symbol 6 4 When the screen shows blood symbol clean your finger with alcohol swab Let it dry completely CHOL Code CHOL 5 Place the puncturer on your finger g 85 27 Press the trigger on the puncturer mor aL Lift up the puncturer wn mc Get a drop of blood rt l 15 Put the drop of blood on the edge of the test iS m EOS 88 gt t05 strip target area The blood will be absorbed gt and cause the target area to turn red The testing reaction starts when the meter beeps The meter starts to count down 150 seconds then shows your result on the screen The meter stores your result in its memo
26. the maximum output power of the communications equipment Rated maximum output Separation distance according to frequency of transmitterm power of transmitter 150 kHz to 80 MHz 80 MHz to 800 MHz 800 MHz to 2 5 GHz 0 0 38 10 3 8 700 12 For transmitters rated at a maximum output power not listed above the recommended separation distance d in metres m can be estimated using the equation applicable to the frequency of the transmitter where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer NOTE 1 At 80 MHz and 800 MHz the separation distance for the higher frequency range applies NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people 46 Lancet Included in the package Specification Sterile 30G Manufacturer Sterilance Medical Suzhou Inc Address No 68 Litanghe Road Xiangcheng Suzhou Jiangsu 215133 P R China CE n Q STERILE R Manufacturer Global Medical Market Corp Address Room No 1112 Ace Tower 9th Bldg 345 30 Kasan Dong Kumchon Ku Seoul Korea
27. ulti Function Monitoring System Setting Date and Time 1 The meter will automatically enter the setting mode after you install the batteries 2 Press S button to obtain correct month 3 Press M button to confirm up setting and shifts to the date setting 4 Repeat the same steps to set the date hour and minute 5 When you finish setting the meter will turn off automatically Checking the Unit of Measurement Before you get started GlucoAlpha 3 in 1 meter can measure your blood glucose cholesterol and uric acid in units as described below A Push Switch Up Push Switch Down Unit Decimal point Decimal point Yes mya No Yes m d No No mya Ys You should check this setting every time you put batteries into your meter Use a screwdriver to adjust the switch he Batteries Installation E y 1 Slide battery cover off from the back of the meter 2 Insert two AAA size batteries 1 5V into battery slot 3 Slide battery cover back 11 sing Check Strip to Check the Meter 1 Insert the check strip into the test strip slot on the meter 2 The screen should display OK If X appears on the screen remove the check strip and reinsert it If X displays again stop the test and call our customer support 12 Control Check with Glucose Cholesterol Uric Acid Control Solutions hen to Run a Control Check with Glucose Cholesterol